Search Results

Search found 27891 results on 1116 pages for 'boot options menu'.

Page 255/1116 | < Previous Page | 251 252 253 254 255 256 257 258 259 260 261 262  | Next Page >

  • How to fix 'grub error file not found' when installing 12.04?

    - by Tomasz Grabowski
    i'm trying to install Ubuntu. I don't know if it is important, but i'm trying to install it on external HDD. In the end i have external bootable HDD which only displays: error: file not found grub recovery> From the beginning: I've downloaded ubuntu-12.04-desktop-i386.iso I've used LiLi USB Creator (LinuxLive) to create bootable pendrive from that image I've bootet from it, it works I've clicked "Try ubuntu", it works too. I've used GParted to look over drivers (disks) My primary embedded disk is seen as /dev/sda My attached external disk as /dev/sdb My PenDrive as /dev/sdc I've created partitions on /dev/sdb Fist partition for system (over 200GiB) Second was there already (it's xsf, and i don't want to touch it :P) Third is extended partition, with 1 locital partiton (10GiB) for swap I've started installation i've choose "somethin else" in ... i belive secound screeb then is selected /dev/sdb as boot disk for first partiton of /dev/sdb i set i want ext3 file system, i've check "formattin" checkbox, and mount path set to "/" firs logical partiton set as swap partition After installation finished, i restarted my computer. When i boot from my primary disc it's work ok, my previous operating system - vista - works ok. When i set my BIOS to boot from my external disc, i only get that message: error: file not found grub recovery> I've try to reinstall it, but didn't help... In desperation, i've try to read a bit about that "grub recovery" command-line and experiment a bit... I'm not sure if this has had any point, or if it give you some information (notice, that i don't know what i'm doing :P ) when i've type command: insmod (hd1,1)/boot/grub/linux.mod i've get message: unknown filesystem the same with: insmod (hd1,msdos1)/boot/grub/linux.mod the same with: insmod ext3 but i get no message after command: insmod ext2 ... notice that i really don't know what this command exactly do, but than i thought that maybe if i reinstall ubuntu with ext2 filesystem, it will work. I've done that, but symptoms are the same. I've go back to that Live version of ubuntu, filesystem and basics directories seems to be present on /dev/sdb1 ... i'm completely unfamiliar with GRUB. I'm also don't know which wersion of GRUB it is, i hope there is only one version on ubuntu-12.04-desktop-i386.iso Any help? Thax

    Read the article

  • I can't install Ubuntu 12.04.1 on iMac G5

    - by user89004
    So, I have this iMac G5 that doesn't have iSight, only a small light sensor I think undernieth, machine model 8.2. I tried burning a Ubuntu 12.04.1 PowerPC 64bit .iso to a cd but the computer just won't boot it, I don't know why. Next I tried with a USB but it wouldn't let me boot that either, I created the usb on my dad's win7 laptop as the process was way easier than on freakin Mac or Ubuntu (no command typing AT ALL on windows) I'm able to get into openfirmware and type boot usb and it does show some weird writing that scrolls so fast I can't see anything and then it just gives me this huge no sign like a stop sign and freezez. The sign is grey and the line in the middle is tilted towards the left. An other issue I'm having with hdiutil is that I can't convert the stupid .iso I just downloaded into a .img because the file keeps on dissapearing right when it's done converting it. I used the syntax from Ubuntu support how to create a bootable usb drive under Mac OS X. I even didn't include the 2 stupid ~ that are shown in the syntax that are completly worthless, God only know why they put them there, and I even tried running the whole thing as root with sudo su before the command. The funny thing is that if I convert something smaller it works. The command I was using is hdiutil convert -format UDRW -o /path/to/target.img /path/to/ubuntu.iso I even tried hdiutil convert /path/to/ubuntu.iso -format UDRW -o /path/to/target.img but the same thing happens, the dummy .img.dmg file dissapears when the conversion is done no matter where I set the output file to go. I have tried several different folders, the same thing happens with all of them. I also tried burning a Ubuntu mini iso on a cd, can't remember if it was 11.10 or 12.10 but even thoguh holding c when the iMac boots up does show me the cd and I can boot from it, I get this weird error upon hitting install, it says something like invalid memory access, release keys and error strings I can't read. I don't have any original DVDs from this iMac and can't run hardware diagnostics. WHatever option I try at the command prompt from the mini ubuntu cd I get the same result, error code and openfirmware backdrop that's frozen. I noticed that the pen drive I created on my dads Win7 laptop is formated with MS-DOS but I can still mount it no problem, so it shouldn't have a problem booting it, right? I used the advice on ubuntu.com to make it, from here. Also, my partition is HFS+ so I can't use it as a hard drive and boot from it. I don' have 2 partitions either, just one HDD, one partition. Please help!!!

    Read the article

  • Beginner: How to Make Explorer Always Show the Full Path in Windows 8

    - by Taylor Gibb
    In older versions of Windows the Title Bar used to display your current location in the file system. In Windows 8 this is not the default behavior, however, you can enable it if you wish to. Display the Full Path in the Windows Explorer Title Bar Press the Windows + E keyboard combination to open Windows Explorer and then switch over to the View tab. On the right-hand side click on options and then select Change folder and search options from the drop-down. When the Folder Options dialog opens, switch over to the View options. Here you will need to tick the Display the full path in the title bar check box. That’s all there is to it. How To Switch Webmail Providers Without Losing All Your Email How To Force Windows Applications to Use a Specific CPU HTG Explains: Is UPnP a Security Risk?

    Read the article

  • New Features Of WordPress 3.3 You Must Know

    - by Gopinath
    After months of beta testing, WordPress 3.3 version is going to be released at the end of this month. There are several new features packed in the new version and few of them are going to excite WordPress admins. In this post we are going to discuss about the exciting new features. 1. Drag and Drop Media Uploads One of the biggest improvements in this version of WordPress is it’s all new media uploader. Now you can upload multiple files by just dragging & dropping, instantly resize  the images and filter files by their type. The media upload sports a brand new look WordPress adopted the Pupload plugin to power its media uploader component and it’s written by the same team who created the popular TinyMCE editor plugin. 2. Improved Admin Bar(Toolbar) The admin bar or newly called toolbar has got handful of makeovers. The not so much used items like Search box and other elements are removed to make sure that the bar is not clumsy. The user menu and the related options are moved to the right like how we see in Google’s user bar. Also there are few changes to the colour of the bar to make it more eye friendly. 3. Fly out Admin Menus All the left side bar menus of WordPress admin are now sports a fly out menu style to save a click. In the previous versions if you want to access a sub menu on the left side bar, you need to first click on the category and then choose the menu item from the expanded list. Now on just mouse over you will see a flyout of menu items. 4. Adaptive Admin – Layout Auto Adjust To Fit Various Devices If you own an iPad or any other so called tablets then you are going to love this feature. The admin site of WordPress has got a lot more friendly with tablets and smartphones. WordPress now auto adjusts layout to fit the device through which you are accessing the admin site.  Accessing admin dashboard on your tablets is going to be more fun. 5. Other Features Now that we have read the most useful 4 features here is a small list of other features that may interest you Nice Tooltips are displayed where ever possible to help the newbies to understand the usage of admin site Responsive Layouts jQuery 1.7 and jQuery UI 1.8.16 are the power horses of WordPress Performance improvements This article titled,New Features Of WordPress 3.3 You Must Know, was originally published at Tech Dreams. Grab our rss feed or fan us on Facebook to get updates from us.

    Read the article

  • Invalid assignment left hand side

    - by JoelM
    I'm getting an invalid assignment left hand side. What I'm trying to do is, to use jscolor http://jscolor.com to define the color of polygons im drawing via Mapbender http://mapbender.org. What I do: Select a polygon by clicking on it, then open the options dialog (seperate window) where I have several options including the color. MyCode: if (isTransactional) {str += "\t\t<tr>\n"; var options = ["insert", "update", "delete", "abort", "pick"]; for (var i = 0 ; i < options.length ; i++) { var onClickText = "this.disabled=true;var result = window.opener.formCorrect(document, '"+featureTypeElementFormId+"');"; onClickText += "if (result.isCorrect) {"; onClickText += "window.opener.dbGeom('"+options[i]+"', "+memberIndex+"); "; // onClickText += "window.close();"; onClickText += "}"; onClickText += "else {"; onClickText += "alert(result.errorMessage);this.disabled=false;" onClickText += "}"; if (options[i] == "insert" && hasGeometryColumn && (!fid || showSaveButtonForExistingGeometries)) { str += "\t\t\t<td><input type='button' name='saveButton' value='"+msgObj.buttonLabelSaveGeometry+"' onclick=\""+onClickText+"\" /></td>\n"; } if (!featureTypeMismatch && fid) { if (options[i] == "update" && hasGeometryColumn) { str += "\t\t\t<td><input type='button' name='updateButton' value='"+msgObj.buttonLabelUpdateGeometry+"' onclick=\""+onClickText+"\"/></td>\n"; } if (options[i] == "delete"){ var deleteOnClickText = "var deltrans = confirm('"+msgObj.messageConfirmDeleteGeomFromDb+"');"; deleteOnClickText += "if (deltrans){"; deleteOnClickText += onClickText + "}"; str += "\t\t\t<td><input type='button' name='deleteButton' value='"+msgObj.buttonLabelDeleteGeometry+"' onclick=\""+deleteOnClickText+"\"/></td>\n"; }} if (options[i] == "abort") { str += "\t\t\t<td><input type='button' name='abortButton' value='"+msgObj.buttonLabelAbort+"' onclick=\"window.close();\" /></td>\n"; } if (options[i] == "pick") { var color; str += "<td><input class='color' name='color' id='cPick' onchange="+color+"></td>"; str += "<td><input type='text' id='text' value="+color+"></td>"; //color = document.getElementById('cPick').value; //var color2 = color; //alert(color2); } }str += "\t\t</tr>\n";}str += "\t</table>\n";str += "<input type='hidden' id='fid' value='"+fid+"'>"; //str += "<input type='text' name='mb_wfs_conf'>"; str += "</form>\n";}return str;} The Application: It is a Mapbender application to display maps and draw on it. You can draw points, lines and polygons also merge and split them. You can also select the polygons that you have drawn to alter them. Using: PHP, JavaScript, HTML, CSS, Mapbender, jQuery, Geoserver, PostgreSQL, WMS, WFS-T Sorry guys, but I think I'm wasting your time. Will ask this question in GIS specified Q&A. Thank you for the input. Greetings Joël

    Read the article

  • Issues writing to serial port on MAC OSX using unistd.h in c

    - by Schuyler
    I am trying to write to a bluetooth device on MAC OSX using the unistd.h Linux functions in c. I am connecting fine and writing the first few bytes with success. When I try to write other commands to it (there are bytes added to the write buffer every 15ms), I don't see any results even though the write() function returns 1 (write success). If you start a write and it doesn't finish by the time you try to start another write (since it is non-blocking), could that possibly screw up the initial write? (If so, is there any way to check if a write has completed?) That is the only thing I can think of since the writes are occurring fairly frequently and the first two are successfully sent. qwbyte() simply adds a byte to the output array and increments its length The open port function: BAMid = -1; struct termios options; struct termios originalTTYAttrs; // Open the serial port read/write, nonblocking, with no controlling terminal, and don't wait for a connection. BAMid = open(strPath, O_RDWR | O_NOCTTY | O_NONBLOCK); if (BAMid == -1) { printf("Error opening serial port %s - %s(%d).\n", strPath, strerror(errno), errno); goto error; } // Issue TIOCEXCL ioctl to prevent additional opens except by root-owned processes. if (ioctl(BAMid, TIOCEXCL) == -1) { printf("Error setting TIOCEXCL on %s - %s(%d).\n", strPath, strerror(errno), errno); goto error; } // Get the current options and save them so we can restore the default settings later. if (tcgetattr(BAMid, &originalTTYAttrs) == -1) { printf("Error getting tty attributes %s - %s(%d).\n", strPath, strerror(errno), errno); goto error; } // The serial port attributes such as timeouts and baud rate are set by modifying the termios // structure and then calling tcsetattr() to cause the changes to take effect. Note that the // changes will not become effective without the tcsetattr() call. options = originalTTYAttrs; // Set raw input (non-canonical) mode, with reads blocking until either a single character // has been received or a one second timeout expires. [should be moot since we are leaving it as nonblocking] cfmakeraw(&options); options.c_cc[VMIN] = 1; options.c_cc[VTIME] = 10; cfsetspeed(&options, B57600); // Set 57600 baud options.c_cflag |= CS8; // Use 8 bit words // Cause the new options to take effect immediately. if (tcsetattr(BAMid, TCSANOW, &options) == -1) { printf("Error setting tty attributes %s - %s(%d).\n", strPath, strerror(errno), errno); goto error; } //flush old transmissions if (tcflush(BAMid,TCIOFLUSH) == -1) { printf("Error flushing BAM serial port - %s(%d).\n", strerror(errno), errno); } oBufLength = 0; // Ask it to start if (! qwbyte(CmdStart) ) { goto error; } if (! qwbyte(CmdFull) ) { goto error; } //this transmit works txbytes(); printf("success opening port!"); return -1; // Failure path error: if (BAMid != -1) { close(BAMid); } printf("returning an error--%d",errno); return errno; } The write function (txbytes): int i, bufSize, numBytes; if(oBufLength != 0) { //if the output array isn't empty //duplicating the output array and its size so it can //be overwritten while this write is occuring printf("about to transmit: "); for(i = 0; i < oBufLength; i++) { printf(" %u",oBuf[i]); tempBuf[i] = oBuf[i]; } printf("\n"); bufSize = oBufLength; oBufLength = 0; numBytes = write(BAMid, &tempBuf, bufSize); printf("bytes written = %d\n",numBytes); if (numBytes == -1) { printf("Error writing to port - %s(%d).\n", strerror(errno), errno); } return (numBytes 0); } else { return 0; }

    Read the article

  • scroll into view the selected element

    - by yb007
    hi all, i am a newbie to javascript... i have two select boxes with multiple selection enabled.When i select an element from first select box it scrolls into view the corrosponding element from the second list.The single selection goes fine in all browsers explorer,firefox,chrome. now, if i select the first,last element from the first selection box the second select box does not scrolls into view the last selected element in chrome browser.although , it works fine in internet explorer and firefox. Please help me to make it run in google chrome browser. <html> <head> <script language="javascript"> function SyncListsL(){ for (var i = 0; i <= [document.puser.user_select.length]-1; i++) { if(document.puser.user_select.options[i].selected == true) { document.puser.user_select2.options[i].selected=true; document.puser.user_select.options[i].selected=true; } else{ document.puser.user_select2.options[i].selected = false; document.puser.user_select.options[i].selected=false; } } } function SyncListsR(){ for (i = 0; i <= [document.puser.user_select2.length]-1; i++) { if(document.puser.user_select2.options[i].selected == true) { document.puser.user_select.options[i].selected=true; document.puser.user_select2.options[i].selected=true; } else{ document.puser.user_select.options[i].selected = false; document.puser.user_select2.options[i].selected=false; } } } </script> <title>scrollintoview</title> </head> <body bgcolor="e2dbc5"> <form name="puser" > <table align="center"> <tr> <td align="right" bgcolor="#eeeadd"> <font size=2> <select name="user_select2" multiple size="5" onChange="SyncListsR()" style="width:35mm"> <option value="a1" title="a1">a1</option> <option value="a2" title="a2">a2</option> <option value="ab" title="ab">ab</option> <option value="abc" title="abc">abc</option> <option value="e1" title="e1">e1</option> <option value="e2" title="e2">e2</option> <option value="new" title="new">new</option> </select> </font></td> <td align="left" bgcolor="#eeeadd"> <font size=2> <select name="user_select" multiple size="5" onChange="SyncListsL()" style="width:50mm"> <option value="first" title="first">first</option> <option value="last" title="last">last</option> <option value="ghi" title="ghi">ghi</option> <option value="User" title="User">User</option> <option value="ed" title="ed">ed</option> <option value="edit" title="edit">edit</option> <option value="second" title="second">second</option> </select> </font></td> </tr> </table> </form> </body> </html>

    Read the article

  • Zend models and database relathionships

    - by user608341
    Hi people, i'm starting with Zend Framework and I'm a little bit confused with models and relathionships (one-to-many, many-to-many etc). The "Zend Framework Quick Start" says to create a Zend_Db_Table, a Data Mapper and finally our model class Suppose we have a database like this: table A ( id integer primary key, name varchar(50) ); table B ( id integer primary key, a_id integer references A ); then, i'll create: Application_Model_DbTable_A extends Zend_Db_Table_Abstract, Application_Model_AMapper, Application_Model_A, Application_Model_DbTable_B extends Zend_Db_Table_Abstract, Application_Model_BMapper, Application_Model_B, if I understood, i've to store the references informations in Application_Model_DbTable_A: protected $_dependentTables = array('B'); and Application_Model_DbTable_B: protected $_referenceMap = array( 'A' => array( 'columns' => array('a_id'), 'refTableClass' => 'A', 'refColums' => array('id') ) ); and my models class: class Application_Model_A { protected $_id; protected $_name; public function __construct(array $options = null) { if(is_array($options)) { $this->setOptions($options); } } public function __set($name, $value) { $method = 'set' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } $this->$method($value); } public function __get($name) { $method = 'get' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } return $this->$method(); } public function setOptions(array $options) { $methods = get_class_methods($this); foreach ($options as $key => $value) { $method = 'set' . ucfirst($key); if (in_array($method, $methods)) { $this->$method($value); } } return $this; } public function setName($name) { $this->_name = (string) $name; return $this; } public function getName() { return $this->_name; } public function setId($id) { $this->_id = (int) $id; return $this; } public function getId() { return $this->_id; } class Application_Model_B { protected $_id; protected $_a_id; public function __construct(array $options = null) { if(is_array($options)) { $this->setOptions($options); } } public function __set($name, $value) { $method = 'set' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } $this->$method($value); } public function __get($name) { $method = 'get' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } return $this->$method(); } public function setOptions(array $options) { $methods = get_class_methods($this); foreach ($options as $key => $value) { $method = 'set' . ucfirst($key); if (in_array($method, $methods)) { $this->$method($value); } } return $this; } public function setA_id($a_id) { $this->_a_id = (int) $a_id; return $this; } public function getA_id() { return $this->_a_id; } public function setId($id) { $this->_id = (int) $id; return $this; } public function getId() { return $this->_id; } it's that right?

    Read the article

  • jqGrid Coloring an entire line in Grid based upon a cells value

    - by Thomas
    Hi all, i know it's been asked before but i cant get it to run and i'm out of things to try. So i want to colorize a row in a Grid if its value is not 1 - i use a custom formatter for this. The formatter itself works, thats not the problem. I've tried multple ways I've found so far on the web - adding a class, directly adding css code, using setRowData, using setCell.... Here are my examples - none of them worked for me (linux, ff363) - any pointer would be gratly appreciated. 27.05.2010_00:00:00-27.05.2010_00:00:00 is my row id <style> .state_inactive { background-color: red !important; } .state_active { background-color: green !important; } </style> function format_state (cellvalue, options, rowObject) { var elem='#'+options.gid; if (cellvalue != 1) { jQuery('#list2').setRowData(options.rowID,'', {'background-color':'#FF6F6F'}); jQuery('#list2').setRowData('27.05.2010_00:00:00-27.05.2010_00:00:00', '',{'background-color':'#FF6F6F'}); for (var cnt=0;cnt<rowObject.length;cnt=cnt+1) { jQuery(elem).setCell(options.rowId,cnt,'','state_inactive',''); jQuery(elem).setCell('"'+options.rowId+'"',cnt,'','state_inactive'); jQuery(elem).setCell('"'+options.rowId+'"',cnt,'5', {'background-color':'#FF6F6F'},''); } } else { for (var cnt=0;cnt<rowObject.length;cnt=cnt+1) { jQuery(elem).setCell(options.rowId,cnt,'','state_active',''); } } <!-- dont modify, we simply added the class above--> return cellvalue; } Thanks, Thomas

    Read the article

  • java heap allocation

    - by gurupriyan.e
    I tried to increase the heap size like the below C:\Data\Guru\Code\Got\adminservice\adminservice>java -Xms512m -Xmx512m Usage: java [-options] class [args...] (to execute a class) or java [-options] -jar jarfile [args...] (to execute a jar file) where options include: -client to select the "client" VM -server to select the "server" VM -hotspot is a synonym for the "client" VM [deprecated] The default VM is client. -cp <class search path of directories and zip/jar files> -classpath <class search path of directories and zip/jar files> A ; separated list of directories, JAR archives, and ZIP archives to search for class files. -D<name>=<value> set a system property -verbose[:class|gc|jni] enable verbose output -version print product version and exit -version:<value> require the specified version to run -showversion print product version and continue -jre-restrict-search | -jre-no-restrict-search include/exclude user private JREs in the version search -? -help print this help message -X print help on non-standard options -ea[:<packagename>...|:<classname>] -enableassertions[:<packagename>...|:<classname>] enable assertions -da[:<packagename>...|:<classname>] -disableassertions[:<packagename>...|:<classname>] disable assertions -esa | -enablesystemassertions enable system assertions -dsa | -disablesystemassertions disable system assertions -agentlib:<libname>[=<options>] load native agent library <libname>, e.g. -agentlib:hprof see also, -agentlib:jdwp=help and -agentlib:hprof=help -agentpath:<pathname>[=<options>] load native agent library by full pathname -javaagent:<jarpath>[=<options>] load Java programming language agent, see java.lang.instrument It gave the help message as above - Does it mean that it was allocated?

    Read the article

  • Xpath > How can I select a node based on both its attributes and content?

    - by Andrew Kirk
    Sample XML: <assignments> <assignment id="911990211" section-id="1942268885" item-count="21" sources="foo"> <options> <value name="NumRetakes">4</value> <value name="MultipleResultGrading">6</value> <value name="MaxFeedbackAttempts">-1</value> <value name="ItemTakesBeforeHint">1</value> <value name="TimeAllowed">0</value> </options> </assignment> <assignment id="1425185257" section-id="1505958877" item-count="4" sources="bar"> <options> <value name="NumRetakes">0</value> <value name="MultipleResultGrading">6</value> <value name="MaxFeedbackAttempts">3</value> <value name="ItemTakesBeforeHint">1</value> <value name="TimeAllowed">0</value> </options> </assignment> <assignments> Using XPath, I would like to select all assignments/assignment/options/value nodes where the nodes "name" attribute is "MaxFeedbackAttempts" and the nodes content is "-1". That is to say, I want to return each node that looks like: <value name="MaxFeedbackAttempts">-1</value> I can get each assignments/assignment/options/value node with the specified attribute using: //assignment/options/value[@name="MaxFeedbackAttempts"] I am just not sure how to refine this path to also limit the results based on the nodes content. Is there any way to do this using XPath?

    Read the article

  • android zxing intentintegrator

    - by cristi _b
    I've written the following code that works fine if you decide to scan a QR code (using zxing) and store it in private storage but in case you decide to cancel scanning, it crashes and the file previously stored content disappears. I think it might be a design error, not sure why. Below is relevant code ... /** * menu generation */ @Override public boolean onCreateOptionsMenu(Menu menu) { MenuInflater inflater = getMenuInflater(); inflater.inflate(R.menu.menu, menu); return true; } /** * menu handling */ @Override public boolean onOptionsItemSelected(MenuItem item) { Context context = getApplicationContext(); Toast toast = Toast.makeText(context, "", Toast.LENGTH_LONG); toast.setGravity(Gravity.FILL_HORIZONTAL, 0, 0); switch (item.getItemId()) { case R.id.qrScan: IntentIntegrator integrator = new IntentIntegrator(this); integrator.initiateScan(); return true; case R.id.qrReset: File dir = getFilesDir(); File file = new File(dir, qrCodeFile); boolean deleted = file.delete(); return true; case R.id.appClose: this.finish(); return true; default: return super.onOptionsItemSelected(item); } } ... public void onActivityResult(int requestCode, int resultCode, Intent intent) { IntentResult scanResult = IntentIntegrator.parseActivityResult(requestCode, resultCode, intent); Context context = getApplicationContext(); Toast toast = Toast.makeText(context, "", Toast.LENGTH_SHORT); if (scanResult != null) { FileOutputStream fos = null; CharSequence text = scanResult.getContents(); try { fos = openFileOutput(qrCodeFile, Context.MODE_PRIVATE); try { fos.write(text.toString().getBytes()); fos.close(); toast.setGravity(Gravity.FILL_HORIZONTAL, 0, 0); toast.setText("Code saved"); toast.show(); } catch (IOException ex) { toast.setGravity(Gravity.FILL_HORIZONTAL, 0, 0); toast.setText("Invalid code"); toast.show(); Logger.getLogger(MainActivity.class.getName()).log(Level.SEVERE, null, ex); } } catch (FileNotFoundException ex) { toast.setGravity(Gravity.FILL_HORIZONTAL, 0, 0); toast.setText("Error while saving"); toast.show(); Logger.getLogger(MainActivity.class.getName()).log(Level.SEVERE, null, ex); } } else { toast.setGravity(Gravity.FILL_HORIZONTAL, 0, 0); toast.setText("Invalid code"); toast.show(); } }

    Read the article

  • Skip HTML escape in custom label_tag helper in Rail 3

    - by tricote
    Hi, I have this nice class ErrorFormBuilder that allows me to add the error description near the corresponding field in the form view : class ErrorFormBuilder < ActionView::Helpers::FormBuilder #Adds error message directly inline to a form label #Accepts all the options normall passed to form.label as well as: # :hide_errors - true if you don't want errors displayed on this label # :additional_text - Will add additional text after the error message or after the label if no errors def label(method, text = nil, options = {}) #Check to see if text for this label has been supplied and humanize the field name if not. text = text || method.to_s.humanize #Get a reference to the model object object = @template.instance_variable_get("@#{@object_name}") #Make sure we have an object and we're not told to hide errors for this label unless object.nil? || options[:hide_errors] #Check if there are any errors for this field in the model errors = object.errors.on(method.to_sym) if errors #Generate the label using the text as well as the error message wrapped in a span with error class text += " <br/><span class=\"error\">#{errors.is_a?(Array) ? errors.first : errors}</span>" end end #Add any additional text that might be needed on the label text += " #{options[:additional_text]}" if options[:additional_text] #Finally hand off to super to deal with the display of the label super(method, text, options) end end But the HTML : text += " <br/><span class=\"error\">#{errors.is_a?(Array) ? errors.first : errors}</span>" is escaped by default in the view... I tried to add the {:escape = false} option : super(method, text, options.merge({:escape => false})) without success Is there any way to bypass this behavior ? Thanks

    Read the article

  • ecma script deleting in a <select> "list"

    - by Tyzak
    hello, i have following function: function delete_auswahl() { var anzahl =document.getElementById ("warenkorbfeld").length ; for (var i =0; i<=anzahl; i++) { if (document.getElementById ("warenkorbfeld").options[i].selected==true) { if (document.getElementById ("warenkorbfeld").options[i].id == "Margherita" ) gesamtbetrag = gesamtbetrag - 4; if (document.getElementById ("warenkorbfeld").options[i].id=="Salami" ) gesamtbetrag = gesamtbetrag - 4.50; if (document.getElementById ("warenkorbfeld").options[i].id=="Hawaii" ) gesamtbetrag = gesamtbetrag - 5.50; document.getElementById ("warenkorbfeld").options[i]=null; i--;// auf der gleichen stelle bleiben, da dass nächste feld nachrückt } } document.getElementById('gesamtbetrag').innerHTML=gesamtbetrag ; } before i added values with function hinzu (pizza) { NeuerEintrag = new Option(pizza, pizza, false, false); document.getElementById("warenkorbfeld").options[document.getElementById("warenkorbfeld").length] = NeuerEintrag ; if (pizza=="Margherita") { gesamtbetrag = gesamtbetrag + 4; } if (pizza=="Salami") { gesamtbetrag = gesamtbetrag + 4.50; } if (pizza=="Hawaii") { gesamtbetrag = gesamtbetrag + 5.50; } document.getElementById('gesamtbetrag').innerHTML=gesamtbetrag ; } now, in the delete function doesn't substract the price. despite this, all works. what's wrong with this term? if (document.getElementById ("warenkorbfeld").options[i].id == "Margherita" ) gesamtbetrag = gesamtbetrag - 4; thanks in advance

    Read the article

  • jQuery form zip code to state function

    - by Dakota R.
    I'm trying to convert a preexisting javascript function into a jQuery function. The function comes from http://javascript.internet.com/forms/zip-to-state.html and aims to convert a user-entered zip code into a state. I'm using jQuery 1.3.2, with all the necessary plugins, but I'm not very familiar with jQuery syntax and how to convert this from plain ol' Javascript syntax. The setState function takes two parameters, the zip code element and the state element, so I'm trying to do something like this: $('$zip_code').change( function () { setState($(this), $('#state')); }); Any thoughts on this syntax? Thanks, Dakota function getState(zip) { if ((parseInt(zipString.substr(zip / 4, 1), 16) & Math.pow(2, zip % 4)) && (zip.length == 5)) for (var i = 0; i < stateRange.length; i += 7) if (zip <= 1 * stateRange.substr(i, 5)) return stateRange.substr(i + 5, 2); return null; } function setState(txtZip, optionBox) { if (txtZip.value.length != 5 || isNaN(txtZip.value / 4)) { optionBox.options[0].selected = true; alert("Please enter a 5 digit, numeric zip code."); return; } var state = getState(txtZip.value); for (var i = 0; i < optionBox.options.length; i++) if (optionBox.options[i].value == state) return optionBox.options[i].selected = true; for (var i = 0; i < optionBox.options.length; i++) if (optionBox.options[i].value == "XX") return optionBox.options[i].selected = true; }

    Read the article

  • Deleting an option in a <select> list

    - by Tyzak
    hello, i have following function: function delete_auswahl() { var anzahl =document.getElementById ("warenkorbfeld").length ; for (var i =0; i<=anzahl; i++) { if (document.getElementById ("warenkorbfeld").options[i].selected==true) { if (document.getElementById ("warenkorbfeld").options[i].id == "Margherita" ) gesamtbetrag = gesamtbetrag - 4; if (document.getElementById ("warenkorbfeld").options[i].id=="Salami" ) gesamtbetrag = gesamtbetrag - 4.50; if (document.getElementById ("warenkorbfeld").options[i].id=="Hawaii" ) gesamtbetrag = gesamtbetrag - 5.50; document.getElementById ("warenkorbfeld").options[i]=null; i--;// auf der gleichen stelle bleiben, da dass nächste feld nachrückt } } document.getElementById('gesamtbetrag').innerHTML=gesamtbetrag ; } before i added values with function hinzu (pizza) { NeuerEintrag = new Option(pizza, pizza, false, false); document.getElementById("warenkorbfeld").options[document.getElementById("warenkorbfeld").length] = NeuerEintrag ; if (pizza=="Margherita") { gesamtbetrag = gesamtbetrag + 4; } if (pizza=="Salami") { gesamtbetrag = gesamtbetrag + 4.50; } if (pizza=="Hawaii") { gesamtbetrag = gesamtbetrag + 5.50; } document.getElementById('gesamtbetrag').innerHTML=gesamtbetrag ; } now, in the delete function doesn't substract the price. despite this, all works. what's wrong with this term? if (document.getElementById ("warenkorbfeld").options[i].id == "Margherita" ) gesamtbetrag = gesamtbetrag - 4; thanks in advance

    Read the article

  • Jscrollpane causese text to disappear on internet explorer

    - by Crippletoe
    Hello all, in my current site, i am using the new Jscrollpane in order to generate a scrollbar for a menu (not my descision but the designer's descision so i dont wanna get into how 90's that all looks like..). my menu is based on a <UL> the <li> elements inside it have the attribute "text-align: right;". my problem that on IE alone the menu text doesnt show when i apply the ScrollPane to the menu. when i delete the ScrollPane function from my code- the menu re-appears. i checked the page with "microsoft Expression" DOM inspector in order to examine how IE sees my code and i can see the <li> elements there, only the text inside them is missing. when i disable the "text-align: right;" for the <li> in my CSS, the text shows again. i suspect this has something to do with the jScrollPane's containing which is relatively aligned but i cannot be sure.. can anyone suggest some fix for this problem? a link to a page where you can see the problem is here: http://kaplanoland.com/index.php?option=com_content&view=article&id=2&Itemid=12 the problematic menu is on the right side of the page. on every browser but IE you can see the text. only on IE not. my CSS code for that menu (not including the jScrollPane CSS) is here: div#menu2{ position: absolute; top: 123px; right: 36px; width: 330px; height: 150px; } div#menu2_scroll{ /*the actual scroller*/ height: 150px; } div#menu2 div#menu2_contain{ } div#menu2 li{ text-align: right; } div#menu2 li span{ line-height: 18px; } div#menu2 a:link, div#menu2 a:visited{ color: #808285 ; font-family: Arial, Helvetica, sans-serif ; font-size: 12px ; } div#menu2 a:hover, div#menu2 li#current a{ color: #000000 ; font-family: Arial, Helvetica, sans-serif ; font-size: 12px ; } div#menu2 span.separator{ display: block; padding-top: 12px; padding-bottom: 40px; font-family: Arial, Helvetica, sans-serif; font-size: 12px; font-weight: bold; color: #000000; } div#menu2 span.separator span { padding-top: 12px; border-top-width: 1px; border-top-style: solid; border-top-color: #808285; } thank you all so much.

    Read the article

  • Dynamic Select boxes page load

    - by Chris
    Hello, I have a dynamic chained select box that I am attempting to show the value of on a page load. In my chained select box, it will default to the first option within the select box on page load, could anyone provide assitance? I stumbled upon this thread, but I can't seem to translate what they are doing with that answer to my language of CF. Dynamic chained drop downs on page refresh Here is the JS script I am using. function dynamicSelect(id1, id2) { // Feature test to see if there is enough W3C DOM support if (document.getElementById && document.getElementsByTagName) { // Obtain references to both select boxes var sel1 = document.getElementById(id1); var sel2 = document.getElementById(id2); // Clone the dynamic select box var clone = sel2.cloneNode(true); // Obtain references to all cloned options var clonedOptions = clone.getElementsByTagName("option"); // Onload init: call a generic function to display the related options in the dynamic select box refreshDynamicSelectOptions(sel1, sel2, clonedOptions); // Onchange of the main select box: call a generic function to display the related options in the dynamic select box sel1.onchange = function() { refreshDynamicSelectOptions(sel1, sel2, clonedOptions); } } } function refreshDynamicSelectOptions(sel1, sel2, clonedOptions) { // Delete all options of the dynamic select box while (sel2.options.length) { sel2.remove(0); } // Create regular expression objects for "select" and the value of the selected option of the main select box as class names var pattern1 = /( |^)(select)( |$)/; var pattern2 = new RegExp("( |^)(" + sel1.options[sel1.selectedIndex].value + ")( |$)"); // Iterate through all cloned options for (var i = 0; i < clonedOptions.length; i++) { // If the classname of a cloned option either equals "select" or equals the value of the selected option of the main select box if (clonedOptions[i].className.match(pattern1) || clonedOptions[i].className.match(pattern2)) { // Clone the option from the hidden option pool and append it to the dynamic select box sel2.appendChild(clonedOptions[i].cloneNode(true)); } } } Thanks so much for any assistance

    Read the article

  • Why is this line breaking Rails with Passenger on DreamHost?

    - by Frew
    Ok, so I have a Rails app set up on DreamHost and I had it working a while ago and now it's broken. I don't know a lot about deployment environments or anything like that so please forgive my ignorance. Anyway, it looks like the app is crashing at this line in config/environment.rb: require File.join(File.dirname(__FILE__), 'boot') config/boot.rb is pretty much normal, but I'll include it here anyway. # Don't change this file! # Configure your app in config/environment.rb and config/environments/*.rb RAILS_ROOT = "#{File.dirname(__FILE__)}/.." unless defined?(RAILS_ROOT) module Rails class << self def boot! unless booted? preinitialize pick_boot.run end end def booted? defined? Rails::Initializer end def pick_boot (vendor_rails? ? VendorBoot : GemBoot).new end def vendor_rails? File.exist?("#{RAILS_ROOT}/vendor/rails") end def preinitialize load(preinitializer_path) if File.exist?(preinitializer_path) end def preinitializer_path "#{RAILS_ROOT}/config/preinitializer.rb" end end class Boot def run load_initializer Rails::Initializer.run(:set_load_path) end end class VendorBoot < Boot def load_initializer require "#{RAILS_ROOT}/vendor/rails/railties/lib/initializer" Rails::Initializer.run(:install_gem_spec_stubs) end end class GemBoot < Boot def load_initializer self.class.load_rubygems load_rails_gem require 'initializer' end def load_rails_gem if version = self.class.gem_version gem 'rails', version else gem 'rails' end rescue Gem::LoadError => load_error $stderr.puts %(Missing the Rails #{version} gem. Please `gem install -v=#{version} rails`, update your RAILS_GEM_VERSION setting in config/environment.rb for the Rails version you do have installed, or comment out RAILS_GEM_VERSION to use the latest version installed.) exit 1 end class << self def rubygems_version Gem::RubyGemsVersion if defined? Gem::RubyGemsVersion end def gem_version if defined? RAILS_GEM_VERSION RAILS_GEM_VERSION elsif ENV.include?('RAILS_GEM_VERSION') ENV['RAILS_GEM_VERSION'] else parse_gem_version(read_environment_rb) end end def load_rubygems require 'rubygems' min_version = '1.1.1' unless rubygems_version >= min_version $stderr.puts %Q(Rails requires RubyGems >= #{min_version} (you have #{rubygems_version}). Please `gem update --system` and try again.) exit 1 end rescue LoadError $stderr.puts %Q(Rails requires RubyGems >= #{min_version}. Please install RubyGems and try again: http://rubygems.rubyforge.org) exit 1 end def parse_gem_version(text) $1 if text =~ /^[^#]*RAILS_GEM_VERSION\s*=\s*["']([!~<>=]*\s*[\d.]+)["']/ end private def read_environment_rb File.read("#{RAILS_ROOT}/config/environment.rb") end end end end # All that for this: Rails.boot! Does anyone have any ideas? I am not getting any errors in the log or on the page. -fREW

    Read the article

  • Understanding Basic Prototyping & Updating Key/Value pairs

    - by JordanD
    First time poster, long time lurker. I'm trying to learn some more advanced features of .js, and have two ojectives based on the pasted code below: I would like to add methods to a parent class in a specific way (by invoking prototype). I intend to update the declared key/value pairs each time I make an associated method call. execMTAction as seen in TheSuper will execute each function call, regardless. This is by design. Here is the code: function TheSuper(){ this.options = {componentType: "UITabBar", componentName: "Visual Browser", componentMethod: "select", componentValue: null}; execMTAction(this.options.componentType, this.options.componentName, this.options.componentMethod, this.options.componentValue); }; TheSuper.prototype.tapUITextView = function(val1, val2){ this.options = {componentType: "UITextView", componentName: val1, componentMethod: "entertext", componentValue: val2}; }; I would like to execute something like this (very simple): theSuper.executeMTAction(); theSuper.tapUITextView("a", "b"); Unfortunately I am unable to overwrite the "this.options" in the parent, and the .tapUITextView method throws an error saying it cannot find executeMTAction. All I want to do, like I said, is to update the parameters in the parent, then have executeMTAction run each time I make any method call. That's it. Any thoughts? I understand this is basic but I'm coming from a long-time procedural career and .js seems to have this weird confluence of oo/procedural that I'm having a bit of difficulty with. Thanks for any input!

    Read the article

  • WPF: Can't get to original source from ExecutedRoutedEventArgs

    - by Ikhail
    I have a problem getting to the original source of a command using ExecutedRoutedEventArgs. I'm creating a simple splitbutton, in which a menu will appear below a dedicated button, as another button is pressed. When I click a menuitem in the appearing menu a command is fired. This command is registered on the splitbutton. And the idea is to get to the menuitem beeing clicked, by using the ExecutedRoutedEventsArgs. Ok, now the problem. If I choose to have the popup menu shown by default (IsOpen="True") and I click one of the menuitems I can get to the originalsource (thus the menuitem) from the ExecutedRoutedEventArgs - no problem. However, if I first click the button to show the menu and THEN click on a menuitem, the originalsource of the command will be the button instead of the MenuItem! Here's the controltemplate for the splitbutton: <ControlTemplate TargetType="{x:Type usc:SplitButton}"> <StackPanel Orientation="Horizontal"> <Button Name="mybutton"> <StackPanel> <Popup usc:SplitButton.IsPopup="True" IsOpen="True" Name="myPopup" PlacementTarget="{Binding ElementName=mybutton}" StaysOpen="False" Placement="Bottom"> <Border BorderBrush="Beige" BorderThickness="1"> <Menu Width="120"> <MenuItem Header="item1" Command="usc:SplitButton.MenuItemClickCommand" /> <MenuItem Header="item2" /> <MenuItem Header="item3" /> </Menu> </Border> </Popup> <TextBlock Text="MySplitbutton" /> </StackPanel> </Button> <Button Content="OK" Command="usc:SplitButton.ShowMenuCommand" /> </StackPanel> </ControlTemplate> The OK button fires a ShowMenuCommand on the SplitButton, which sets the IsOpen property on the Popup to True. Any ideas why the OK button (after having activated the menu) is the OriginalSource when a menuitem is clicked? Thanks.

    Read the article

  • Running OpenStack Icehouse with ZFS Storage Appliance

    - by Ronen Kofman
    Couple of months ago Oracle announced the support for OpenStack Cinder plugin with ZFS Storage Appliance (aka ZFSSA).  With our recent release of the Icehouse tech preview I thought it is a good opportunity to demonstrate the ZFSSA plugin working with Icehouse. One thing that helps a lot to get started with ZFSSA is that it has a VirtualBox simulator. This simulator allows users to try out the appliance’s features before getting to a real box. Users can test the functionality and design an environment even before they have a real appliance which makes the deployment process much more efficient. With OpenStack this is especially nice because having a simulator on the other end allows us to test the complete set of the Cinder plugin and check the entire integration on a single server or even a laptop. Let’s see how this works Installing and Configuring the Simulator To get started we first need to download the simulator, the simulator is available here, unzip it and it is ready to be imported to VirtualBox. If you do not already have VirtualBox installed you can download it from here according to your platform of choice. To import the simulator go to VirtualBox console File -> Import Appliance , navigate to the location of the simulator and import the virtual machine. When opening the virtual machine you will need to make the following changes: - Network – by default the network is “Host Only” , the user needs to change that to “Bridged” so the VM can connect to the network and be accessible. - Memory (optional) – the VM comes with a default of 2560MB which may be fine but if you have more memory that could not hurt, in my case I decided to give it 8192 - vCPU (optional) – the default the VM comes with 1 vCPU, I decided to change it to two, you are welcome to do so too. And here is how the VM looks like: Start the VM, when the boot process completes we will need to change the root password and the simulator is running and ready to go. Now that the simulator is up and running we can access simulated appliance using the URL https://<IP or DNS name>:215/, the IP is showing on the virtual machine console. At this stage we will need to configure the appliance, in my case I did not change any of the default (in other words pressed ‘commit’ several times) and the simulated appliance was configured and ready to go. We will need to enable REST access otherwise Cinder will not be able to call the appliance we do that in Configuration->Services and at the end of the page there is ‘REST’ button, enable it. If you are a more advanced user you can set additional features in the appliance but for the purpose of this demo this is sufficient. One final step will be to create a pool, go to Configuration -> Storage and add a pool as shown below the pool is named “default”: The simulator is now running, configured and ready for action. Configuring Cinder Back to OpenStack, I have a multi node deployment which we created according to the “Getting Started with Oracle VM, Oracle Linux and OpenStack” guide using Icehouse tech preview release. Now we need to install and configure the ZFSSA Cinder plugin using the README file. In short the steps are as follows: 1. Copy the file from here to the control node and place them at: /usr/lib/python2.6/site-packages/cinder/volume/drivers/zfssa 2. Configure the plugin, editing /etc/cinder/cinder.conf # Driver to use for volume creation (string value) #volume_driver=cinder.volume.drivers.lvm.LVMISCSIDriver volume_driver=cinder.volume.drivers.zfssa.zfssaiscsi.ZFSSAISCSIDriver zfssa_host = <HOST IP> zfssa_auth_user = root zfssa_auth_password = <ROOT PASSWORD> zfssa_pool = default zfssa_target_portal = <HOST IP>:3260 zfssa_project = test zfssa_initiator_group = default zfssa_target_interfaces = e1000g0 3. Restart the cinder-volume service: service openstack-cinder-volume restart 4. Look into the log file, this will tell us if everything works well so far. If you see any errors fix them before continuing. 5. Install iscsi-initiator-utils package, this is important since the plugin uses iscsi commands from this package: yum install -y iscsi-initiator-utils The installation and configuration are very simple, we do not need to have a “project” in the ZFSSA but we do need to define a pool. Creating and Using Volumes in OpenStack We are now ready to work, to get started lets create a volume in OpenStack and see it showing up on the simulator: #  cinder create 2 --display-name my-volume-1 +---------------------+--------------------------------------+ |       Property      |                Value                 | +---------------------+--------------------------------------+ |     attachments     |                  []                  | |  availability_zone  |                 nova                 | |       bootable      |                false                 | |      created_at     |      2014-08-12T04:24:37.806752      | | display_description |                 None                 | |     display_name    |             my-volume-1              | |      encrypted      |                False                 | |          id         | df67c447-9a36-4887-a8ff-74178d5d06ee | |       metadata      |                  {}                  | |         size        |                  2                   | |     snapshot_id     |                 None                 | |     source_volid    |                 None                 | |        status       |               creating               | |     volume_type     |                 None                 | +---------------------+--------------------------------------+ In the simulator: Extending the volume to 5G: # cinder extend df67c447-9a36-4887-a8ff-74178d5d06ee 5 In the simulator: Creating templates using Cinder Volumes By default OpenStack supports ephemeral storage where an image is copied into the run area during instance launch and deleted when the instance is terminated. With Cinder we can create persistent storage and launch instances from a Cinder volume. Booting from volume has several advantages, one of the main advantages of booting from volumes is speed. No matter how large the volume is the launch operation is immediate there is no copying of an image to a run areas, an operation which can take a long time when using ephemeral storage (depending on image size). In this deployment we have a Glance image of Oracle Linux 6.5, I would like to make it into a volume which I can boot from. When creating a volume from an image we actually “download” the image into the volume and making the volume bootable, this process can take some time depending on the image size, during the download we will see the following status: # cinder create --image-id 487a0731-599a-499e-b0e2-5d9b20201f0f --display-name ol65 2 # cinder list +--------------------------------------+-------------+--------------+------+-------------+ |                  ID                  |    Status   | Display Name | Size | Volume Type | … +--------------------------------------+-------------+--------------+------+------------- | df67c447-9a36-4887-a8ff-74178d5d06ee |  available  | my-volume-1  |  5   |     None    | … | f61702b6-4204-4f10-8bdf-7da792f15c28 | downloading |     ol65     |  2   |     None    | … +--------------------------------------+-------------+--------------+------+-------------+ After the download is complete we will see that the volume status changed to “available” and that the bootable state is “true”. We can use this new volume to boot an instance from or we can use it as a template. Cinder can create a volume from another volume and ZFSSA can replicate volumes instantly in the back end. The result is an efficient template model where users can spawn an instance from a “template” instantly even if the template is very large in size. Let’s try replicating the bootable volume with the Oracle Linux 6.5 on it creating additional 3 bootable volumes: # cinder create 2 --source-volid f61702b6-4204-4f10-8bdf-7da792f15c28 --display-name ol65-bootable-1 # cinder create 2 --source-volid f61702b6-4204-4f10-8bdf-7da792f15c28 --display-name ol65-bootable-2 # cinder create 2 --source-volid f61702b6-4204-4f10-8bdf-7da792f15c28 --display-name ol65-bootable-3 # cinder list +--------------------------------------+-----------+-----------------+------+-------------+----------+-------------+ |                  ID                  |   Status  |   Display Name  | Size | Volume Type | Bootable | Attached to | +--------------------------------------+-----------+-----------------+------+-------------+----------+-------------+ | 9bfe0deb-b9c7-4d97-8522-1354fc533c26 | available | ol65-bootable-2 |  2   |     None    |   true   |             | | a311a855-6fb8-472d-b091-4d9703ef6b9a | available | ol65-bootable-1 |  2   |     None    |   true   |             | | df67c447-9a36-4887-a8ff-74178d5d06ee | available |   my-volume-1   |  5   |     None    |  false   |             | | e7fbd2eb-e726-452b-9a88-b5eee0736175 | available | ol65-bootable-3 |  2   |     None    |   true   |             | | f61702b6-4204-4f10-8bdf-7da792f15c28 | available |       ol65      |  2   |     None    |   true   |             | +--------------------------------------+-----------+-----------------+------+-------------+----------+-------------+ Note that the creation of those 3 volume was almost immediate, no need to download or copy, ZFSSA takes care of the volume copy for us. Start 3 instances: # nova boot --boot-volume a311a855-6fb8-472d-b091-4d9703ef6b9a --flavor m1.tiny ol65-instance-1 --nic net-id=25b19746-3aea-4236-8193-4c6284e76eca # nova boot --boot-volume 9bfe0deb-b9c7-4d97-8522-1354fc533c26 --flavor m1.tiny ol65-instance-2 --nic net-id=25b19746-3aea-4236-8193-4c6284e76eca # nova boot --boot-volume e7fbd2eb-e726-452b-9a88-b5eee0736175 --flavor m1.tiny ol65-instance-3 --nic net-id=25b19746-3aea-4236-8193-4c6284e76eca Instantly replicating volumes is a very powerful feature, especially for large templates. The ZFSSA Cinder plugin allows us to take advantage of this feature of ZFSSA. By offloading some of the operations to the array OpenStack create a highly efficient environment where persistent volume can be instantly created from a template. That’s all for now, with this environment you can continue to test ZFSSA with OpenStack and when you are ready for the real appliance the operations will look the same. @RonenKofman

    Read the article

  • Cannot determine ethernet address for proxy ARP on PPTP

    - by Linux Intel
    I installed pptp server on a centos 6 64bit server PPTP Server ip : 55.66.77.10 PPTP Local ip : 10.0.0.1 Client1 IP : 10.0.0.60 centos 5 64bit Client2 IP : 10.0.0.61 centos5 64bit PPTP Server can ping Client1 And client 1 can ping PPTP Server PPTP Server can ping Client2 And client 2 can ping PPTP Server The problem is client 1 can not ping Client 2 and i get this error also on PPTP server error log Cannot determine ethernet address for proxy ARP Ping from Client2 to Client1 PING 10.0.0.60 (10.0.0.60) 56(84) bytes of data. --- 10.0.0.60 ping statistics --- 6 packets transmitted, 0 received, 100% packet loss, time 5000ms route -n on PPTP Server Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.60 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 10.0.0.61 0.0.0.0 255.255.255.255 UH 0 0 0 ppp1 55.66.77.10 0.0.0.0 255.255.255.248 U 0 0 0 eth0 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth0 0.0.0.0 55.66.77.19 0.0.0.0 UG 0 0 0 eth0 route -n On Client 1 Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.1 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 55.66.77.10 70.14.13.19 255.255.255.255 UGH 0 0 0 eth0 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth1 0.0.0.0 70.14.13.19 0.0.0.0 UG 0 0 0 eth0 route -n On Client 2 Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.1 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 55.66.77.10 84.56.120.60 255.255.255.255 UGH 0 0 0 eth1 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth0 0.0.0.0 84.56.120.60 0.0.0.0 UG 0 0 0 eth1 cat /etc/ppp/options.pptpd on PPTP server ############################################################################### # $Id: options.pptpd,v 1.11 2005/12/29 01:21:09 quozl Exp $ # # Sample Poptop PPP options file /etc/ppp/options.pptpd # Options used by PPP when a connection arrives from a client. # This file is pointed to by /etc/pptpd.conf option keyword. # Changes are effective on the next connection. See "man pppd". # # You are expected to change this file to suit your system. As # packaged, it requires PPP 2.4.2 and the kernel MPPE module. ############################################################################### # Authentication # Name of the local system for authentication purposes # (must match the second field in /etc/ppp/chap-secrets entries) name pptpd # Strip the domain prefix from the username before authentication. # (applies if you use pppd with chapms-strip-domain patch) #chapms-strip-domain # Encryption # (There have been multiple versions of PPP with encryption support, # choose with of the following sections you will use.) # BSD licensed ppp-2.4.2 upstream with MPPE only, kernel module ppp_mppe.o # {{{ refuse-pap refuse-chap refuse-mschap # Require the peer to authenticate itself using MS-CHAPv2 [Microsoft # Challenge Handshake Authentication Protocol, Version 2] authentication. require-mschap-v2 # Require MPPE 128-bit encryption # (note that MPPE requires the use of MSCHAP-V2 during authentication) require-mppe-128 # }}} # OpenSSL licensed ppp-2.4.1 fork with MPPE only, kernel module mppe.o # {{{ #-chap #-chapms # Require the peer to authenticate itself using MS-CHAPv2 [Microsoft # Challenge Handshake Authentication Protocol, Version 2] authentication. #+chapms-v2 # Require MPPE encryption # (note that MPPE requires the use of MSCHAP-V2 during authentication) #mppe-40 # enable either 40-bit or 128-bit, not both #mppe-128 #mppe-stateless # }}} # Network and Routing # If pppd is acting as a server for Microsoft Windows clients, this # option allows pppd to supply one or two DNS (Domain Name Server) # addresses to the clients. The first instance of this option # specifies the primary DNS address; the second instance (if given) # specifies the secondary DNS address. #ms-dns 10.0.0.1 #ms-dns 10.0.0.2 # If pppd is acting as a server for Microsoft Windows or "Samba" # clients, this option allows pppd to supply one or two WINS (Windows # Internet Name Services) server addresses to the clients. The first # instance of this option specifies the primary WINS address; the # second instance (if given) specifies the secondary WINS address. #ms-wins 10.0.0.3 #ms-wins 10.0.0.4 # Add an entry to this system's ARP [Address Resolution Protocol] # table with the IP address of the peer and the Ethernet address of this # system. This will have the effect of making the peer appear to other # systems to be on the local ethernet. # (you do not need this if your PPTP server is responsible for routing # packets to the clients -- James Cameron) proxyarp # Normally pptpd passes the IP address to pppd, but if pptpd has been # given the delegate option in pptpd.conf or the --delegate command line # option, then pppd will use chap-secrets or radius to allocate the # client IP address. The default local IP address used at the server # end is often the same as the address of the server. To override this, # specify the local IP address here. # (you must not use this unless you have used the delegate option) #10.8.0.100 # Logging # Enable connection debugging facilities. # (see your syslog configuration for where pppd sends to) debug # Print out all the option values which have been set. # (often requested by mailing list to verify options) #dump # Miscellaneous # Create a UUCP-style lock file for the pseudo-tty to ensure exclusive # access. lock # Disable BSD-Compress compression nobsdcomp # Disable Van Jacobson compression # (needed on some networks with Windows 9x/ME/XP clients, see posting to # poptop-server on 14th April 2005 by Pawel Pokrywka and followups, # http://marc.theaimsgroup.com/?t=111343175400006&r=1&w=2 ) novj novjccomp # turn off logging to stderr, since this may be redirected to pptpd, # which may trigger a loopback nologfd # put plugins here # (putting them higher up may cause them to sent messages to the pty) cat /etc/ppp/options.pptp on Client1 and Client2 ############################################################################### # $Id: options.pptp,v 1.3 2006/03/26 23:11:05 quozl Exp $ # # Sample PPTP PPP options file /etc/ppp/options.pptp # Options used by PPP when a connection is made by a PPTP client. # This file can be referred to by an /etc/ppp/peers file for the tunnel. # Changes are effective on the next connection. See "man pppd". # # You are expected to change this file to suit your system. As # packaged, it requires PPP 2.4.2 or later from http://ppp.samba.org/ # and the kernel MPPE module available from the CVS repository also on # http://ppp.samba.org/, which is packaged for DKMS as kernel_ppp_mppe. ############################################################################### # Lock the port lock # Authentication # We don't need the tunnel server to authenticate itself noauth # We won't do PAP, EAP, CHAP, or MSCHAP, but we will accept MSCHAP-V2 # (you may need to remove these refusals if the server is not using MPPE) refuse-pap refuse-eap refuse-chap refuse-mschap # Compression # Turn off compression protocols we know won't be used nobsdcomp nodeflate # Encryption # (There have been multiple versions of PPP with encryption support, # choose which of the following sections you will use. Note that MPPE # requires the use of MSCHAP-V2 during authentication) # # Note that using PPTP with MPPE and MSCHAP-V2 should be considered # insecure: # http://marc.info/?l=pptpclient-devel&m=134372640219039&w=2 # https://github.com/moxie0/chapcrack/blob/master/README.md # http://technet.microsoft.com/en-us/security/advisory/2743314 # http://ppp.samba.org/ the PPP project version of PPP by Paul Mackarras # ppp-2.4.2 or later with MPPE only, kernel module ppp_mppe.o # If the kernel is booted in FIPS mode (fips=1), the ppp_mppe.ko module # is not allowed and PPTP-MPPE is not available. # {{{ # Require MPPE 128-bit encryption #require-mppe-128 # }}} # http://mppe-mppc.alphacron.de/ fork from PPP project by Jan Dubiec # ppp-2.4.2 or later with MPPE and MPPC, kernel module ppp_mppe_mppc.o # {{{ # Require MPPE 128-bit encryption #mppe required,stateless # }}} IPtables is stopped on clients and server, Also net.ipv4.ip_forward = 1 is enabled on PPTP Server. How can i solve this problem .?

    Read the article

  • PPTP ping client to client error

    - by Linux Intel
    I installed pptp server on a centos 6 64bit server PPTP Server ip : 55.66.77.10 PPTP Local ip : 10.0.0.1 Client1 IP : 10.0.0.60 centos 5 64bit Client2 IP : 10.0.0.61 centos5 64bit PPTP Server can ping Client1 And client 1 can ping PPTP Server PPTP Server can ping Client2 And client 2 can ping PPTP Server The problem is client 1 can not ping Client 2 route -n on PPTP Server Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.60 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 10.0.0.61 0.0.0.0 255.255.255.255 UH 0 0 0 ppp1 55.66.77.10 0.0.0.0 255.255.255.248 U 0 0 0 eth0 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth0 0.0.0.0 55.66.77.19 0.0.0.0 UG 0 0 0 eth0 route -n On Client 1 Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.1 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 55.66.77.10 70.14.13.19 255.255.255.255 UGH 0 0 0 eth0 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth1 0.0.0.0 70.14.13.19 0.0.0.0 UG 0 0 0 eth0 route -n On Client 2 Destination Gateway Genmask Flags Metric Ref Use Iface 10.0.0.1 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 55.66.77.10 84.56.120.60 255.255.255.255 UGH 0 0 0 eth1 10.0.0.0 0.0.0.0 255.0.0.0 U 0 0 0 eth0 0.0.0.0 84.56.120.60 0.0.0.0 UG 0 0 0 eth1 cat /etc/ppp/options.pptpd on PPTP server ############################################################################### # $Id: options.pptpd,v 1.11 2005/12/29 01:21:09 quozl Exp $ # # Sample Poptop PPP options file /etc/ppp/options.pptpd # Options used by PPP when a connection arrives from a client. # This file is pointed to by /etc/pptpd.conf option keyword. # Changes are effective on the next connection. See "man pppd". # # You are expected to change this file to suit your system. As # packaged, it requires PPP 2.4.2 and the kernel MPPE module. ############################################################################### # Authentication # Name of the local system for authentication purposes # (must match the second field in /etc/ppp/chap-secrets entries) name pptpd # Strip the domain prefix from the username before authentication. # (applies if you use pppd with chapms-strip-domain patch) #chapms-strip-domain # Encryption # (There have been multiple versions of PPP with encryption support, # choose with of the following sections you will use.) # BSD licensed ppp-2.4.2 upstream with MPPE only, kernel module ppp_mppe.o # {{{ refuse-pap refuse-chap refuse-mschap # Require the peer to authenticate itself using MS-CHAPv2 [Microsoft # Challenge Handshake Authentication Protocol, Version 2] authentication. require-mschap-v2 # Require MPPE 128-bit encryption # (note that MPPE requires the use of MSCHAP-V2 during authentication) require-mppe-128 # }}} # OpenSSL licensed ppp-2.4.1 fork with MPPE only, kernel module mppe.o # {{{ #-chap #-chapms # Require the peer to authenticate itself using MS-CHAPv2 [Microsoft # Challenge Handshake Authentication Protocol, Version 2] authentication. #+chapms-v2 # Require MPPE encryption # (note that MPPE requires the use of MSCHAP-V2 during authentication) #mppe-40 # enable either 40-bit or 128-bit, not both #mppe-128 #mppe-stateless # }}} # Network and Routing # If pppd is acting as a server for Microsoft Windows clients, this # option allows pppd to supply one or two DNS (Domain Name Server) # addresses to the clients. The first instance of this option # specifies the primary DNS address; the second instance (if given) # specifies the secondary DNS address. #ms-dns 10.0.0.1 #ms-dns 10.0.0.2 # If pppd is acting as a server for Microsoft Windows or "Samba" # clients, this option allows pppd to supply one or two WINS (Windows # Internet Name Services) server addresses to the clients. The first # instance of this option specifies the primary WINS address; the # second instance (if given) specifies the secondary WINS address. #ms-wins 10.0.0.3 #ms-wins 10.0.0.4 # Add an entry to this system's ARP [Address Resolution Protocol] # table with the IP address of the peer and the Ethernet address of this # system. This will have the effect of making the peer appear to other # systems to be on the local ethernet. # (you do not need this if your PPTP server is responsible for routing # packets to the clients -- James Cameron) proxyarp # Normally pptpd passes the IP address to pppd, but if pptpd has been # given the delegate option in pptpd.conf or the --delegate command line # option, then pppd will use chap-secrets or radius to allocate the # client IP address. The default local IP address used at the server # end is often the same as the address of the server. To override this, # specify the local IP address here. # (you must not use this unless you have used the delegate option) #10.8.0.100 # Logging # Enable connection debugging facilities. # (see your syslog configuration for where pppd sends to) debug # Print out all the option values which have been set. # (often requested by mailing list to verify options) #dump # Miscellaneous # Create a UUCP-style lock file for the pseudo-tty to ensure exclusive # access. lock # Disable BSD-Compress compression nobsdcomp # Disable Van Jacobson compression # (needed on some networks with Windows 9x/ME/XP clients, see posting to # poptop-server on 14th April 2005 by Pawel Pokrywka and followups, # http://marc.theaimsgroup.com/?t=111343175400006&r=1&w=2 ) novj novjccomp # turn off logging to stderr, since this may be redirected to pptpd, # which may trigger a loopback nologfd # put plugins here # (putting them higher up may cause them to sent messages to the pty) cat /etc/ppp/options.pptp on Client1 and Client2 ############################################################################### # $Id: options.pptp,v 1.3 2006/03/26 23:11:05 quozl Exp $ # # Sample PPTP PPP options file /etc/ppp/options.pptp # Options used by PPP when a connection is made by a PPTP client. # This file can be referred to by an /etc/ppp/peers file for the tunnel. # Changes are effective on the next connection. See "man pppd". # # You are expected to change this file to suit your system. As # packaged, it requires PPP 2.4.2 or later from http://ppp.samba.org/ # and the kernel MPPE module available from the CVS repository also on # http://ppp.samba.org/, which is packaged for DKMS as kernel_ppp_mppe. ############################################################################### # Lock the port lock # Authentication # We don't need the tunnel server to authenticate itself noauth # We won't do PAP, EAP, CHAP, or MSCHAP, but we will accept MSCHAP-V2 # (you may need to remove these refusals if the server is not using MPPE) refuse-pap refuse-eap refuse-chap refuse-mschap # Compression # Turn off compression protocols we know won't be used nobsdcomp nodeflate # Encryption # (There have been multiple versions of PPP with encryption support, # choose which of the following sections you will use. Note that MPPE # requires the use of MSCHAP-V2 during authentication) # # Note that using PPTP with MPPE and MSCHAP-V2 should be considered # insecure: # http://marc.info/?l=pptpclient-devel&m=134372640219039&w=2 # https://github.com/moxie0/chapcrack/blob/master/README.md # http://technet.microsoft.com/en-us/security/advisory/2743314 # http://ppp.samba.org/ the PPP project version of PPP by Paul Mackarras # ppp-2.4.2 or later with MPPE only, kernel module ppp_mppe.o # If the kernel is booted in FIPS mode (fips=1), the ppp_mppe.ko module # is not allowed and PPTP-MPPE is not available. # {{{ # Require MPPE 128-bit encryption #require-mppe-128 # }}} # http://mppe-mppc.alphacron.de/ fork from PPP project by Jan Dubiec # ppp-2.4.2 or later with MPPE and MPPC, kernel module ppp_mppe_mppc.o # {{{ # Require MPPE 128-bit encryption #mppe required,stateless # }}} IPtables are stopped on clients and server, Also net.ipv4.ip_forward = 1 is enabled on PPTP Server. How can i solve this problem .?

    Read the article

  • SSL certificate on IIS 7

    - by comii
    I am trying to install a SSL certificate on IIS 7. I have download a free trial certificate. After that, this is the steps what I do: Click the Start menu and select Administrative Tools. Start Internet Services Manager and click the Server Name. In the center section, double click on the Server Certificates button in the Security section. From the Actions menu click Complete Certificate Request. Enter the location for the certificate file. Enter a Friendly name. Click OK. Under Sites select the site to be secured with the SSL certificate. From the Actions menu, click Bindings.This will open the Site Bindings window. In the Site Bindings window, click Add. This opens the Add Site Binding window. Select https from the Type menu. Set the port to 443. Select the SSL Certificate you just installed from the SSL Certificate menu. Click OK. This is the step where I get the message: One or more intermediate certificates in the certificate chain are missing. To resolve this issue, make sure that all of intermediate certificates are installed. For more information, see http://support.microsoft.com/kb/954755 After this, when I access the web site on its first page, I get this message: There is a problem with this website's security certificate. What am I doing wrong?

    Read the article

< Previous Page | 251 252 253 254 255 256 257 258 259 260 261 262  | Next Page >