Search Results

Search found 11380 results on 456 pages for 'cpu speed'.

Page 416/456 | < Previous Page | 412 413 414 415 416 417 418 419 420 421 422 423  | Next Page >

  • Ubuntu stopped recognizing my iPod

    - by flashnode
    Rythmbox on Ubuntu 10.10 used to recognize my 3rd gen Nano and transfer mp3s. Now I plug it in and Ubuntu doesn't pop-up that box that asks what you want to do anymore. It is only recognized if I reboot and the thing is plugged in. Here is the output to 'lsusb -v -s bus:device' Bus 001 Device 008: ID 05ac:1262 Apple, Inc. iPod Nano 3.Gen Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x05ac Apple, Inc. idProduct 0x1262 iPod Nano 3.Gen bcdDevice 0.01 iManufacturer 1 Apple Inc. iProduct 2 iPod iSerial 3 000A27001A670128 bNumConfigurations 2 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 500mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x83 EP 3 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 149 bNumInterfaces 3 bConfigurationValue 2 iConfiguration 4 iPod USB Interface bmAttributes 0xc0 Self Powered MaxPower 500mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 1 Audio bInterfaceSubClass 1 Control Device bInterfaceProtocol 0 iInterface 0 AudioControl Interface Descriptor: bLength 9 bDescriptorType 36 bDescriptorSubtype 1 (HEADER) bcdADC 1.00 wTotalLength 30 bInCollection 1 baInterfaceNr( 0) 1 AudioControl Interface Descriptor: bLength 12 bDescriptorType 36 bDescriptorSubtype 2 (INPUT_TERMINAL) bTerminalID 1 wTerminalType 0x0201 Microphone bAssocTerminal 2 bNrChannels 2 wChannelConfig 0x0003 Left Front (L) Right Front (R) iChannelNames 0 iTerminal 0 AudioControl Interface Descriptor: bLength 9 bDescriptorType 36 bDescriptorSubtype 3 (OUTPUT_TERMINAL) bTerminalID 2 wTerminalType 0x0101 USB Streaming bAssocTerminal 1 bSourceID 1 iTerminal 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 1 Audio bInterfaceSubClass 2 Streaming bInterfaceProtocol 0 iInterface 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 1 bNumEndpoints 1 bInterfaceClass 1 Audio bInterfaceSubClass 2 Streaming bInterfaceProtocol 0 iInterface 0 AudioStreaming Interface Descriptor: bLength 7 bDescriptorType 36 bDescriptorSubtype 1 (AS_GENERAL) bTerminalLink 2 bDelay 1 frames wFormatTag 1 PCM AudioStreaming Interface Descriptor: bLength 35 bDescriptorType 36 bDescriptorSubtype 2 (FORMAT_TYPE) bFormatType 1 (FORMAT_TYPE_I) bNrChannels 2 bSubframeSize 2 bBitResolution 16 bSamFreqType 9 Discrete tSamFreq[ 0] 8000 tSamFreq[ 1] 11025 tSamFreq[ 2] 12000 tSamFreq[ 3] 16000 tSamFreq[ 4] 22050 tSamFreq[ 5] 24000 tSamFreq[ 6] 32000 tSamFreq[ 7] 44100 tSamFreq[ 8] 48000 Endpoint Descriptor: bLength 9 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x00c0 1x 192 bytes bInterval 4 bRefresh 0 bSynchAddress 0 AudioControl Endpoint Descriptor: bLength 7 bDescriptorType 37 bDescriptorSubtype 1 (EP_GENERAL) bmAttributes 0x01 Sampling Frequency bLockDelayUnits 0 Undefined wLockDelay 0 Undefined Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 2 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 0 No Subclass bInterfaceProtocol 0 None iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.01 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 208 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x83 EP 3 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 1 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 2 Device Status: 0x0000 (Bus Powered) This ubuntu forum told me to check the automount settings under /apps/nautilus/preferences/media_automount_open in gconf-editor. And I did that. Any clues?

    Read the article

  • What are the most likely bottlenecks determining the performance of CamStudio screen recording?

    - by Steve314
    When doing screen recording, I can get a frame rate of maybe 15 frames per second for the full screen on my 1080p monitor using the XVID codec. I can increase the speed a bit by recording a region, changing screen modes, and tweaking other settings, but I'm curious what hardware upgrades might give me the biggest bang for my buck. My PC is budget, but modern... Athlon 2 X4 645 (3.1GHz, quad core, limited cache) processor. 4GB single channel DDR3 1066 RAM. ASRock motherboard with NVidia GeForce 7025/nForce 630a Chipset. ATI Radeon HD 5450 graphics card - 512MB on board, not configured to steal system RAM. I dual-boot Windows XP and Windows 7. For the moment, XP is my bigger performance concern as it's still my getting-things-done O/S as opposed to my browser-host O/S. My goal is to make a few programming-related tutorials. For a lot of that I don't need screen recording - I can make up some slides, record audio with the PC switched off, yada yada. When I do need screen recording, I'll mostly be recording Notepad++, Visual Studio or a command prompt. Occasionally, I may be recording some kind of graphics or diagram program and using my pre-Bamboo cheap Wacom tablet - I have the CS2 versions of Photoshop and Illustrator, but I'd much more likely be using Microsoft Paint. Basically, what I'll be recording won't be making huge demands on the machine - but recording a fair number of pixels (720p preferred) will be useful. What's particularly wierd - not so long ago I still had a five-year-old Pentium 4 based PC. And (with the same 1080p monitor) it could record at not far from the same frame rate. So clearly the performance issues are more subtle than just throw-money-at-it. My first guess would be that the main bottleneck is the bandwidth for transferring data to/from the graphics card. Is that likely to be correct? In support of that, see this [Radeon HD 5450 review][1] - the memory bandwidth is only 12.8 GB/s. If you can't get data out of graphics memory quickly, you can't transfer it back to the system memory quickly. Apparently, that's slower than some top-end cards in 2002.

    Read the article

  • How to remove RAID flag on unstriped drive without losing data?

    - by Alex Folland
    I have a Gigabyte Z68X-UD4-B3 motherboard. It advertises this new thing called "XHD", which is like RAID but makes a SSD and traditional-style drive work together to enable high speed with high capacity. I don't want to use this feature, and I already have Windows 7 64 installed without using this feature. When I first installed my 2 hard drives (1 SSD and 1 traditional-style drive) in my machine and booted it up for the first time, it ran a program from the mobo that asked me if I wanted to set up XHD. Thinking it would go to some config screen, I said yes. It immediately started doing something with my drives and finished. I considered that strange, but figured it wouldn't matter when I simply install Windows onto my SSD only. I now have my BIOS and Windows running in AHCI mode with no RAID arrays and separate drives. My SSD is one of those new Corsair Force GT drives which loses power every so often, causing Windows to BSOD. I've figured everything out about this problem, including installing the latest firmware from Corsair, and the only way to fix it at this point is by installing Intel Rapid Storage Technology to control AHCI instead of Windows, since the Windows AHCI driver disables the drive's power every once in a while and can't be configured not to do so. I've tried installing Intel Rapid Storage Technology. When I reboot my machine after doing so, it BSODs just after the Windows logo. I've figured out this is because my SSD and my traditional drive are flagged as RAID, as seen in the "Intel Matrix Storage Manager" program found by switching the BIOS hard drive handling to "RAID" mode. This is due to the XHD auto-config program I mentioned earlier. Normally, the BIOS is set to AHCI, and when the drives boot in AHCI mode, they work perfectly. So, I've concluded the data is stored in AHCI mode but the drives' flags are set to RAID. I've figured out that I can accomplish my objective by using the "Intel Matrix Storage Manager" program on the mobo (with "Reset disks to non-RAID"), but doing so would cause it to completely wipe the drives I select. I want to simply toggle these flags from RAID to AHCI so Intel Rapid Storage Technology doesn't fail and cause a BSOD upon booting, but without wiping the drives.

    Read the article

  • Squid on windows loadbalancing only to one server

    - by Martin L.
    After thousands of googles and trying days i cant get the load balancer/failover in squid on windows to work. Iam using squid 2.7. My webservers are 2 single NIC lighttpd and one dual nic lighttpd. server1 in this example is running squid on port 80 and lighttpd on port 8080 (just to test) Requirements: All 3 webservers running lighttpd should be balanced two option for load balancing: Best would be if server1 is busy server2 takes over, if server2 is busy server3 takes over, etc.. Round robin style evenly distributed load. Eg server1 takes first call, server2 second etc.. All requests should be treated the same way (no url rewriting or so on) Sent host headers have to be redirected to every server as http host header, speaking of "server1", "server1.company.internal" and "10.211.1.1". My approach: acl all src all acl manager proto cache_object http_port 80 accel defaultsite=server1.company.internal vhost #reverse proxy entries cache_peer 10.211.2.1 parent 8080 0 no-query originserver round-robin login=PASS name=server1_nic1 cache_peer 10.211.1.2 parent 80 0 no-query originserver round-robin login=PASS name=server2_nic1 cache_peer 10.211.2.3 parent 8080 0 no-query originserver round-robin login=PASS name=server3_nic1 cache_peer 10.211.2.4 parent 8080 0 no-query originserver round-robin login=PASS name=server3_nic2 #decl of names of squid host acl registered_name_hostdomain dstdomain server1.company.internal acl registered_name_host dstdomain server1 #ip of squid host acl registered_name_ip dstdomain 10.211.2.1 # access: redirects the correct squid hostname http_access allow registered_name_hostdomain http_access allow registered_name_host http_access allow registered_name_ip http_access deny all cache_peer_access server1_nic1 allow registered_name_hostdomain cache_peer_access server1_nic1 allow registered_name_host cache_peer_access server1_nic1 allow registered_name_ip cache_peer_access server2_nic1 allow registered_name_hostdomain cache_peer_access server2_nic1 allow registered_name_host cache_peer_access server2_nic1 allow registered_name_ip cache_peer_access server3_nic1 allow registered_name_hostdomain cache_peer_access server3_nic1 allow registered_name_host cache_peer_access server3_nic1 allow registered_name_ip cache_peer_access server3_nic2 allow registered_name_hostdomain cache_peer_access server3_nic2 allow registered_name_host cache_peer_access server3_nic2 allow registered_name_ip cache_peer_access server1_nic1 deny all cache_peer_access server2_nic1 deny all cache_peer_access server3_nic1 deny all cache_peer_access server3_nic2 deny all never_direct allow all Problems: Load balancer does not load balance other than to first server. Only if the first server is killed in any way the second will take over. I have seen the others working at some point, but definitely not as the intended load balancing described above. If the cache_peer_access is not defined sometimes the wrong hostname is sent to the backend webserver and this always depends on the defaultsite= parameter. Probably because the host header on the request to squid is not set and its replaced by defaultsite. Leaving out defaultsite didnt solve the problem. The only workaround i found for this is the current approach with cache_peer_access. Questions: Does the cache_peer_access influence the round-robin? Is there a better workaround to pass the host header to the backed webservers? Which parameters do increase the speed of load balancing or does anyone have a better approach? -Martin

    Read the article

  • Why did Intel drop the Itanium?

    - by Cole Johnson
    I was reading up on the history of the computer and I came along the IA-64 (Itanium) processors. They sounded really interesting and I was confused as to why Intel would decide to drop them. The ability to choose explicitly what 2 instructions you wanted to run in that cycle is a great idea, especially when writing your program in assembly, for example, a faster bootloader. The hundreds of registers should be convincing for any assembly programmer. You could essentially store all the functions variables in the registers if it doesn't call any other ones. The ability to do instructions like this: (qp) xor r1 = r2, r3 ; r1 = r2 XOR r3 (qp) xor r1 = (imm8), r3 ; r1 = (imm8) XOR r3 versus having to do: ; eax = r1 ; ebx = r2 ; ecx = r3 mov eax, ebx ; first put r2 into r1 xor eax, ecx ; then set r1 equivalent to r2 XOR r3 or ; SAME mov eax, (imm32) ; first put (imm32) into r1 xor eax, ecx ; then set r1 equivalent to (imm32) XOR r3 I heard it was because of no backwards x86 comparability, but couldn't thy be fixed by just adding the Pentium circuitry to it and just add a processor flag that would switch it to Itanium mode (like switching to Protected or Long mode) All the great things about it would have surly put them a giant leap ahead of AMD. Any ideas? Sadly this means you will need a very advanced compiler to do this. Or even one per specific model of the CPU. (E.g. a newer version of the Itanium with an extra feature would require different compiler). When I was working on a WinForms (target only had .NET 2.0) project in Visual Studio 2010, I had a compile target of IA-64. That means that there is a .NET runtime that was able to be compiled for IA-64 and a .NET runtime means Windows. Plus, Hamilton's answer mentions Windows NT. Having a full blown OS like Windows NT means that there is a compiler capable of generating IA-64 machine code.

    Read the article

  • Alienware m15x (older model) BSOD investigation

    - by Crishu
    A frined of mine asked me to help him with an Alienware m15x laptop that had a little service history. It was bought in june 2008, serviced in january 2009 for a random fps drop problem, Alienware returned it saying nothing was wrong. The laptop still had hiccups, but after juggling a few drivers and settings, the fps drops weren't as noticeable. Eventually it died in Sept. 2009. It would not boot up locking itself on a white/gray screen. (i think it was overheating .. clocking in 100 degrees Celsius). So back to Alienware it went. They replaced the GPU and all was fine. Up until these blue screens started showing up. One other thing that was updated was the HDD and a Windows 7 reinstall, in August. From then on it seems to have started its BSOD. Could this be the culprit? Why? 0_o The original Windows was Vista but it was upgraded with a digital download/purchase of Windows 7 Home Premium and activated after installing windows. No errors on the old HDD, just on the latest installation. LE:Due note that now the old HDD is used to see if issues re-occur. So please, I am in need of someone who can interpret these windows dump files: Minidump I may have come to some conflicting conclusions. So if someone can clarify each dump/date and the probable cause/error it had; and a final conclusion or solution, we would be very grateful. Also please consult report for other system info I omitted: same link,code: XRWIVLWG If I missed something or if you have any other questions I'll be happy to answer them. Thank you. Good day. Processor: Intel(R) Core(TM)2 Duo CPU T9300 @ 2.50GHz Network Adapter Properties: Broadcom NetLink (TM) Gigabit Ethernet Intel(R) Wireless WiFi Link 4965AGN Video Adapter Properties: Driver Description NVIDIA GeForce 8800M GTX Driver Date 19.08.2009 Driver Version 8.16.11.8681 Driver Provider NVIDIA INF File oem19.inf Hardware ID PCI\VEN_10DE&DEV_060C&SUBSYS_0770152D&REV_A2 Location Information @system32\DRIVERS\pci.sys,#65536;PCI bus %1, device %2, function %3;(1,0,0) PCI Device NVIDIA GeForce 8800M GTX [NoDB] BIOS String Version 62.92.34.0.8 Installed Drivers nvd3dum (8.16.11.8681), nvwgf2um, nvwgf2um Hard Dik Drive: Model ID ST9120823ASG (**older one 120gb**) Model ID WD32000BEKT (new 320gb with fresh OS)

    Read the article

  • Exchange-Server Query

    - by Rudi Kershaw
    First, a little background. I've recently been taken on as a web and software developer for a small company, who has no other in-house IT support. They've been asking my opinion on lots of IT subjects that are quite far out of my comfort zone. I'm definitely not a network admin. Their IT consultancy contractor is pushing them to upgrade their dedicated exchange server, even though it seems like the one they currently have has a lot of life left in it and is running problem free. They say it's "coming to the natural end of it's life". They want to install a monster with a Xeon E5-2420, 32GB RAM, 2x 1TB HDDs, Windows Server 2012 and Microsoft Exchange 2010. They want to charge a small fortune for it. Basically, this system seems massively over the top seeing as it won't be doing anything else other than running as an exchange server for a company with less than 25 email accounts. My employers also have a file server system in-house that hosts three web apps, an SQL server, their local domain, print server and shared folders. That machine is using the same specs as the proposed new one, and it is barely using any of it's potential. I asked if Microsoft Exchange 2010 could be installed on their file server, but they said that MS Exchange can't run on the same system as an SQL server because for some reason they will eat up each others resources (even though the SQL server isn't touching 1% of the current system's CPU or RAM). My question is really, are they trying to rip my employers off? Could MS Exchange be installed on their other server (on a virtual instance or not), or does the old one even need replacing at all? Going with their current suggestion will cost the company in excess of £6k, and it seems entirely unnecessary. I apologies, because I know this is probably a little thin on details, but if I carry on I could end up writing a massive essay that no-one will want to read. I've been doing my research, but I'm not knowledgeable enough make any hard decisions. Let me know if you need any more details. Thank you for any help you can offer. Further Details: The new exchange would need to support Outlook Web App, 25 users, a few public mailboxes, and email exchange with Blackberries.

    Read the article

  • NIC is receiving, but not transmitting at all?

    - by Shtééf
    I'm trying to fix a very strange problem remotely on a machine at a customer site. The machine is a Dell PowerEdge, I believe a 1950 (haven't verified, but the lspci output matches specs I found.) The machine has two similar NICs, identified as Broadcom Corporation NetXtreme II BCM5708 Gigabit Ethernet (rev 12) by lspci, and using the bnx2 driver. (I suspect these are on-board and on the same controller, which is what I'm accustomed to for this type of machine.) The primary interface eth0 works perfectly, and is in fact how I am ssh'd in. However, the secondary interface eth1 is not transmitting. I can see this in ifconfig output, for example, where the TX field is always 0. However, it is receiving, and tcpdump shows ARP requests coming from the ISP's gateway on the other side. The interface is physically connected to a Siemens BSTU4 modem, configured by the ISP. The link is properly set to 10MBps and full duplex, without negotation, as the ISP requested. A small /30 subnet is configured. For the sake of anonimity, let's say the machine is 3.3.3.2/30, and the ISP's gateway .1. The machine has no firewall settings whatsoever. Even running something like arping -I eth1 3.3.3.1, and running tcpdump alongside, shows no traffic whatsoever being transmitted on the interface. (But the other side keeps steadily sending ARP requests, and that is all that can be seen.) What could be causing this? Here's some output, anonymized, which may hopefully help: $ ethtool eth1 Settings for eth1: Supported ports: [ TP ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: Not reported Advertised auto-negotiation: No Speed: 10Mb/s Duplex: Full Port: Twisted Pair PHYAD: 1 Transceiver: internal Auto-negotiation: off Supports Wake-on: d Wake-on: d Link detected: yes $ ip link show eth1 3: eth1: <BROADCAST,MULTICAST,UP> mtu 1500 qdisc pfifo_fast qlen 1000 link/ether 00:15:c5:xx:xx:xx brd ff:ff:ff:ff:ff:ff $ ip -4 addr show eth1 3: eth1: <BROADCAST,MULTICAST,UP> mtu 1500 qdisc pfifo_fast qlen 1000 inet 3.3.3.2/30 brd 3.3.3.3 scope global eth1 $ ip -4 route show match 3.3.3.0/30 3.3.3.0/30 dev eth1 proto kernel scope link src 3.3.3.2 default via 10.0.0.5 dev eth0

    Read the article

  • How to make Windows 7 use the internet connection that I specify

    - by user138957
    I have a LAN adapter and a USB wireless internet connection. When both connected windows 7 always uses the USB. I tried changing the metric values but no luck. Let me explains the steps I took. Currently automatic metric on all adapters. LAN connected. ipconfig shows that it is connected to the correct ip/dns/gateway etc. IPv4 Route table shows Metric 24 Then connected USB. ipconfig shows USB connectivity then LAN in that order. Internet is now through USB. IPv4 Route table shows Metric 4249 for LAN and USB is 41. Gateway for USB shows "on-link". netstat -rn shows USBDEVICE on top. Changed LAN metric to 5 and now the route table shows LAN as 9 (not sure why it added 4) and USB as 41. netstat shows LAN then USB. ipconfig shows LAN then USB. But still connection is through USB. How do I know? Task manager shows utilization only through USB as well as speed is showing around 1mbps rather than LANs 10mbps. How can I get win7 use LAN while USB is connected. I am just trying to use USB as a backup just in case I lose LAN connection. Please help!! I thought i will make USB metric manually to say 10. But it says I have to reconnect for it to be effective. Currently USB still shows below LAN and still has 9 and 41 in the table. Disconnected USB. Table shows LAN metric as 24 (Not sure why it got changed from 9 and setting got reverted by to automatic) Reconnected USB. Now in the setting still shows 10 and the route table shows 11 for USB and LAN shows 4249 (settings shows 4245, 4 less)) For some reason restarting USB is resetting LAN setting when reconnected. Thanks

    Read the article

  • Well....a ghost lives in my server...

    - by tsgiannis
    Hello to every body and greetings from Greece I have a rather unusual situation and i am running out of ideas. I have this old server (IBM x205 - P4 2.4Ghz,3xSCSI 36gb) and i was about a year ago i decided to use it as an additional domain controller,fax & file server...for this task i had a Delock 70154 SATA card along with 2x320 SATA II HDDs Everything was going super smoothly until about 3 weeks ago. I was on a trip and i was informermed when i got back that the server was found frozen...well i considered it was a glitch since a simple powerdown power up fixed everything.Again 2 weeks ago another freeze situation....it got suspicious but again power down power up everything was running.... Last again it frozen and when i power it up it came with a message that the Domain services could not start due to NTDS corruption....booting in safe mode revealed that there was an issue with the SATA Raid (degraded). After a lot of searching i degraded the server...cleaned Active Directory and pulled both HDDs out (one of these was really BAD ) and recovered my files (i had some problems with ho Delock handles the redudant HDD). Right now my server is vanilla simple...with only what the factory installed and here is where the fun begins. Everyday when i arrive at the office i find this particular machine dead..and i mean total dead...just a black screen and nothing else...the cpu fan is working ,the psu is working .keyboard and mouse are dead(they also lock my kvm) ...network is dead.... the machine is DEAD. I power it down forcilly ...i power it up and for the 8 hours i am in the office it works,either idling or running some kind of diagnostic...when i leave the office after some time..it maybe half an hour ...it maybe 4 hours the machine dies...at least this is the information the event log shows (" the previous shutdown at xx:xx:xx was unexpected) Well i must admit i am runnig out of ideas.... I have tried Memtest....nothing Passmark burn in test.....nothing Carefull study of the event log.....nothing Set Instead of restart..BSOD....nothing Power sceheme to sleep...all set to never. i know there are a lot of other tools that heavily stress a machine like occt but .... the machine is old...today i will give them a try nevertheless ..... One idea is to reformat it...but ... i really like to find what is causing this because i could get to a situation that everything is working for a while and kaboom...one day again is dying.. I really need a helping hand and every opinion / idea is well welcomed.... iknow the obvious solution is to never leave the office but....i have a life...sory server...:) P.S this situation with the machine dying some time after is going on for about one week...everyday i would set either the RAID to rebuild....or to copy/recover files and while everythig was working

    Read the article

  • Anti-virus protection question?

    - by DaBaer
    About 4 years ago, I found Kaspersky and have been using the most current version since. Most people try and argue the use of AVG or Avast to me, and there are some very solid reasons I do not go that route. Over the years, I have found Kasp to become bulkier and bulkier, and have had issues setting it up for friends/family/clients. I am just curios on possible recommendations from other users, with my criteria in mind: What I like about Kasp in the past: The license sold in stores in a 3 pack, is considered a commercial license, and emails from Kasp in response to my questions, make it clear that I can do with the 3 licenses that I want, providing I do not use more than 3 installs per Key. So, allowed me to buy 3, 5, and 7 packs, and resell to users at a cheaper cost than what they would pay if they bought their own license. The ability to easily obtain a currently updated .exe for installation on multiple peoples machines. Power of the scan. Kasp has been a good solution for me (even when using a trial license) on cleaning up machines that were badly infected (in which AVG and AVAST were unable to.) Speed of install/update. After a cleanup of malwarebytes, spybot, mcafee stinger, ccleaner, and combofix, I used to be able to get Kasp Int Security installed and updated in around 5 minutes. The issues that I have with the free AV, is strength of protection. In my opinion for someone who is a 'power use' these are good alternatives, because such a user should be trained or knowledgeable enough to be careful and not get themselves in trouble. Most of the users I assist, are too PC ignorant to know any better, and go hogwild on the web. It has been my experience that the number of people coming back to me with spyware/malware/virus issues since I have converted from AVG to Kasp has been cut down to around 20% of what it used to be 4 or 5 years ago. In a perfect world, I could install and use Kasp Internet Security 2008, and be very happy. But this is not the case anymore. So after this long description of what I used, and have used, does anyone have any good recommendations on AV that isn't going to cost me too much per install?

    Read the article

  • Can only bring up one of two interfaces

    - by mstaessen
    I'm having a bizarre issue with my HP Proliant DL 360 G4p server. It has two gigabit ethernet interfaces but I can bring up only one of them. This is starting to freak me out and that's why I turned here. I'm running the x64 ubuntu 11.10 server edition. lshw -c network shows that the second interface is disabled. I have no idea why ans how to enable it. $ sudo lshw -c network *-network:0 description: Ethernet interface product: NetXtreme BCM5704 Gigabit Ethernet vendor: Broadcom Corporation physical id: 2 bus info: pci@0000:02:02.0 logical name: eth0 version: 10 serial: 00:18:71:e3:6d:26 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 66MHz capabilities: pcix pm vpd msi bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.119 duplex=full firmware=5704-v3.27b, ASFIPMIc v2.36 ip=10.48.8.x latency=64 link=yes mingnt=64 multicast=yes port=twisted pair speed=100Mbit/s resources: irq:25 memory:fdf70000-fdf7ffff *-network:1 DISABLED description: Ethernet interface product: NetXtreme BCM5704 Gigabit Ethernet vendor: Broadcom Corporation physical id: 2.1 bus info: pci@0000:02:02.1 logical name: eth1 version: 10 serial: 00:18:71:e3:6d:25 capacity: 1Gbit/s width: 64 bits clock: 66MHz capabilities: pcix pm vpd msi bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.119 firmware=5704-v3.27b latency=64 link=no mingnt=64 multicast=yes port=twisted pair resources: irq:26 memory:fdf60000-fdf6ffff If I try to ifup eth1, then I get $ sudo ifup eth1 Ignoring unknown interface eth1=eth1. I figured that's what happens when there is no eth1 listed in /etc/network/interfaces. But when I add the configuration for eth1, I still can't ifup. $ sudo ifup eth1 RTNETLINK answers: File exists Failed to bring up eth1. I've also tried ifconfig eth1 up but without any result. For clarity, I have added a masked version of /etc/network/interfaces. I don't think it is the cause of the problem though. $ cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet static address 10.48.8.x netmask 255.255.255.y network 10.48.8.z broadcast 10.48.8.t gateway 10.48.8.u auto eth1 iface eth1 inet static address 193.190.253.x netmask 255.255.255.y network 193.190.253.z broadcast 193.190.253.t gateway 193.190.253.u I really need some help fixing this. It's driving me crazy. Thanks.

    Read the article

  • System won't boot: Gigabyte HD 7790 1GB OC GPU issue or Corsair VS550 PSU issue?

    - by MGOwen
    Installed a new GPU, and PC won't boot. Turn it on and: No monitor signal at all (tried HDMI and VGA via DVI, on 2 working monitors). CPU and GPU fans DO spin, but No system beeps, no sounds from drives (they might make a small noise in the first 1 second or so, but there's definitely no OS loading or anything like that) If hit "power off" button it turns off immediately (no holding down for 3 seconds like usual) If I put my old HD 5670 GPU back in, everything works fine. But (plot twist!) card is not totally dead. My friend put it in his PC, and it works fine (he even played a game for 15 minutes, no issues). He has a Corsair TX850 850W and a Gigabyte MB. So my main theory is: the GPU isn't getting enough power from the PSU. But is it: Bad PSU? Seems unlikely, since it works fine with the other GPU. Also, the PSU Is brand new and 550W (single 42A/504W 12V rail). Overkill for this GPU. Corsair is a decent brand, but maybe just mine is faulty? Bad GPU? Could it be drawing more power than it should be, somehow, or something? Supposedly HD 7790 needs only 21A/75W on the 12v rail, though this one is factory overclocked a bit... but should that triple the power requirement? Something else? Could there be a motherboard incompatibility somehow? Both MB and GPU are less than a year old and PCI Express 3.0 x16. Things I've tried: Re-seating the video card Testing PC with old GPU (works fine, same PCIe slot). Checked AMD's stated amp/watt requirements of a 7790 and my PSU (see above). My PSU can output twice the amps (single rail) and 5x the Wattage a 7790 needs. Here are the full specs: Gigabyte HD 7790 1GB OC GPU Corsair VS550 550W PSU 4GB RAM AsRock H61M U3S3 motherboard i3-2100 500GB SATA HDD (2007-ish) blu-ray drive (new) PCI 802.11g card Edit: Motherboard BIOS Update seems to have fixed it. (If anyone has same problem and it doesn't work, comment here).

    Read the article

  • Will spreading your servers load not just consume more recourses

    - by Saif Bechan
    I am running a heavy real-time updating website. The amount of recourses needed per user are quite high, ill give you an example. Setup Every visit The application is php/mysql so on every visit static and dynamic content is loaded. Recourses: apache,php,mysql Every second (no more than a second will just be too long) The website needs to be updated real-time so every second there is an ajax call thats updates the website. Recourses: jQuery,apache,php,mysql Avarage spending for single user (spending one minute and visited 3 pages) Apache: +/- 63 requests / responsess serving static and dynamic content (img,css,js,html) php: +/- 63 requests / responses mysql: +/- 63 requests / responses jquery: +/- 60 requests / responses Optimization I want to optimize this process, but I think that maybe it would be just the same in the end. Before implementing and testing (which will take weeks) I wanted to have some second opinions from you guys. Every visit I want to start off with having nginx in the front and work as a proxy to deliver the static content. Recources: Dynamic: apache,php,mysql Static: nginx This will spread the load on apache a lot. Every Second For the script that loads every second I want to set up Node.js server side javascript with nginx in te front. I want to set it up that jquery makes a request ones a minute, and node.js streams the data to the client every second. Recources: jQuery,nginx,node.js,mysql Avarage spending for single user (spending one minute and visited 3 pages) Nginx: 4 requests / responsess serving mostly static conetent(img,css,js) Apache: 3 requests only the pages php: 3 requests only the pages node.js: 1 request / 60 responses jquery: 1 request / 60 responses mysql: 63 requests / responses Optimization As you can see in the optimisation the load from Apache and PHP are lifted and places on nginx and node.js. These are known for there light footprint and good performance. But I am having my doubts, because there are still 2 programs extra loaded in the memory and they consume cpu. So it it better to have less programs that do the job, or more. Before I am going to spend a lot of time setting this up I would like to know if it will be worth the while.

    Read the article

  • Lots of dropped packages when tcpdumping on busy interface

    - by Frands Hansen
    My challenge I need to do tcpdumping of a lot of data - actually from 2 interfaces left in promiscuous mode that are able to see a lot of traffic. To sum it up Log all traffic in promiscuous mode from 2 interfaces Those interfaces are not assigned an IP address pcap files must be rotated per ~1G When 10 TB of files are stored, start truncating the oldest What I currently do Right now I use tcpdump like this: tcpdump -n -C 1000 -z /data/compress.sh -i any -w /data/livedump/capture.pcap $FILTER The $FILTER contains src/dst filters so that I can use -i any. The reason for this is, that I have two interfaces and I would like to run the dump in a single thread rather than two. compress.sh takes care of assigning tar to another CPU core, compress the data, give it a reasonable filename and move it to an archive location. I cannot specify two interfaces, thus I have chosen to use filters and dump from any interface. Right now, I do not do any housekeeping, but I plan on monitoring disk and when I have 100G left I will start wiping the oldest files - this should be fine. And now; my problem I see dropped packets. This is from a dump that has been running for a few hours and collected roughly 250 gigs of pcap files: 430083369 packets captured 430115470 packets received by filter 32057 packets dropped by kernel <-- This is my concern How can I avoid so many packets being dropped? These things I did already try or look at Changed the value of /proc/sys/net/core/rmem_max and /proc/sys/net/core/rmem_default which did indeed help - actually it took care of just around half of the dropped packets. I have also looked at gulp - the problem with gulp is, that it does not support multiple interfaces in one process and it gets angry if the interface does not have an IP address. Unfortunately, that is a deal breaker in my case. Next problem is, that when the traffic flows though a pipe, I cannot get the automatic rotation going. Getting one huge 10 TB file is not very efficient and I don't have a machine with 10TB+ RAM that I can run wireshark on, so that's out. Do you have any suggestions? Maybe even a better way of doing my traffic dump altogether.

    Read the article

  • SIGINT and SIGTSTP ignored by most common applications

    - by Vašek Potocek
    After the last upgrade to my Fedora, a strange behaviour started occurring in X terminal applications. I can't seem to stop any process using Ctrl+C, it just results in printing ^C to the console. Similarly, Ctrl+Z prints ^Z and the process goes on. Both work well in non-graphical virtual consoles. I checked stty -a and it seems perfectly normal: speed 38400 baud; rows 24; columns 80; line = 0; intr = ^C; quit = ^\; erase = ^?; kill = ^U; eof = ^D; eol = M-^?; eol2 = M-^?; swtch = M-^?; start = ^Q; stop = ^S; susp = ^Z; rprnt = ^R; werase = ^W; lnext = ^V; flush = ^O; min = 1; time = 0; -parenb -parodd cs8 hupcl -cstopb cread -clocal -crtscts -ignbrk brkint -ignpar -parmrk -inpck -istrip -inlcr -igncr icrnl ixon -ixoff -iuclc ixany imaxbel iutf8 opost -olcuc -ocrnl onlcr -onocr -onlret -ofill -ofdel nl0 cr0 tab0 bs0 vt0 ff0 isig icanon iexten echo echoe echok -echonl -noflsh -xcase -tostop -echoprt echoctl echoke This is independent of the terminal (gnome-terminal, XFCE4 terminal, xterm). I later noticed that it may not be caused by the terminal at all: INT or TSTP sent directly to the respective process are ignored, too. This comprises various applications I used to terminate using Ctrl+C on a regular basis (and which often don't have any better means of exiting): cat, find, tail -f, java, ping, mplayer when stuck on a broken file... Even bash ignores Ctrl+C when I want to break a command line I have been entering and then changed my mind (no ^C is printed in this case). I need to delete it character by character (of which there may be hundreds if filename completion has been used) or intentionally run the unwanted command. Strangely enough, vim does recognize Ctrl+C—just to say its "use :quit", of course. This is extremely annoying and prevents me from working efficiently. Everything had been working until lately, maybe a week ago or so. I can not find any possible causes in Google, perhaps I'm trying wrong search terms or misidentifying the main problem. What could be it and how could I revert the standard behaviour, please? Update Ctrl+Z works sometimes. It seems that in the very first terminal I launch after logging in it stops the running command but stops working after that.

    Read the article

  • Windows 7 & Virtual PC and Internet (gateway) problems on host PC

    - by Mufasa
    I upgraded to Windows 7 on a PC that is a few years old. The CPU was one revision away from having Hyper-V on it. So, I had to install Microsoft Virtual PC 2007 (v6.0.156.0) to run full XP instances instead of the seamless XP virtualization that is advertised so much. That's fine though; the 'older' version is useful since I use it to run different versions of the whole XP/IE stack for testing. (I'm a web developer.) ...And for the one 16-bit application we still use at the office for scheduling. * sigh * The virtual instances work fine, including networking. My issue is that after a reboot or coming out of sleep mode, my host Windows 7 won't connect to the Internet. It will connect to the local network fine. If I disable the "Virtual Machine Network Services" item (I'll call "VMNS" from here on) in the LAN Connection properties box, it starts working. But than the Virtual PC instances lose their network connectivity. If I re-enable VMNS again in the same instance, everything works (Internet on host and in the virtualized instances). But after the next reboot/sleep cycle this starts over. The route table gave me a clue though. When doing a cycle w/ VMNS enabled: IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 On-link 10.0.3.51 20 0.0.0.0 0.0.0.0 10.0.10.10 10.0.3.51 276 ... After VMNS is disabled, the first route goes away. I assume that is for VMNS to intercept virtualized instance's network connections and forward them correctly? Just a guess though. More info: I checked my Firewall settings and Services (because I'm sort of a control nazi and turn off a lot) but couldn't find anything that made sense and if turned on changed anything. So it might be something there I'm missing, but I don't know what. My current hacked solution: So, I figured I'd mess with the routes myself to see if that helped, it did. If I run a route delete 0.0.0.0 on the universal (0.0.0.0) gateway routes, and add back in just the 2nd line with route add 0.0.0.0 mask 0.0.0.0 10.0.10.10--the one that points to my actual gateway (10.0.10.10)--then I don't have to mess with the disable/enable cycle of VMNS, and everything works. Running those two commands is faster then bringing up connection options and disabling and re-enabling VMNS, but I still don't want to have use that hack script every boot either. (Oh, and I also tried messing with hard-coding TCP/IP settings in my network adapter, including setting high metrics, etc., but that didn't help either.) Any suggestions on the right way to fix this?

    Read the article

  • What is the probable failure - no BSOD, no event log, monitors sleeping, force reboot required

    - by Tyler
    Every 3 to 15 days, my PC freezes. This typically happens when the computer is idle, I'm coming home from work, back from vacation, etc. It's never happened while using my computer. The monitors are in power save mode The Caps Lock light on the (wireless) keyboard doesn't work Ctrl-alt-del has no effect, mouse (wireless) has no effect The hardware reset button and single press of power putton have no effect Computer does not appear on the network No BSOD, no memory dump Event logs have no errors or indications of problems near the time of crash. Only messages after reboot indicating that there was a reboot without a clean shutdown. Windows is set to never put the computer to sleep (just the display) Here are the vital stats of the build: OS Windows 8 Pro 64-bit CPU Intel i5-2400 Mobo Intel BOXDP67DE Micro ATX GPU MSI N460GTX Cyclone768D5/OC RAM CORSAIR XMS3 8GB (2 x 4GB) CMX8GX3M2A1333C9 PSU SeaSonic X Series X650 Gold System Drive Samsung 840 Pro 256 GB SSD Data Drive 2 x Western Digital WD20EARS 2TB in hardware RAID 1 Optical Lite-On DVD burner IHAS424-98 And here is the story of how the problem developed and what I've done to diagnose: January 2011, system built with Windows 7 64-bit, runs great. March 2011, Intel replaced the mobo because of the bad sata controllers. October 2012, upgrade to Windows 8 (problems start shortly after). January 2013, system freezes and causes network to fail for the whole house. Unplug the network cable and other devices and PCs can use the internet. Plug it back in, internet goes away for everyone. Reboot and everything is fine. March 2013, install Intel Gigabit CT PCI-E NIC, disable mobo nic in bios. Network strangeness goes away. Freezes are less frequent. Memtest shows no problems (20 passes). Early June 2013, replace Antec PSU with SeaSonic PSU. Mid June 2013, replace OCZ Vertex 2 SSD with Samsung SSD. Late June 2013, get frustrated and hope the community has some good ideas (I'm running out of budget to replace parts). My next plan of attack is setting "Turn off display" to Never and using a screen saver to see how that reacts on the next freeze. It makes me sad to waste power for up to 15 days though. Has anyone out there seen a problem like this? Any ideas on what kind of malfunction would act this way? Ideas of other diagnostic steps to take?

    Read the article

  • Complete machine freezes...at a loss

    - by user28818
    Guys, We built around 12 machines a few months ago to run Ubuntu. They each have the following specs: ASUS Z8NA-D6 motherboard Dual quad core Intel(R) Xeon(R) CPU E5520 @ 2.27GHz OCZ Mod Extreme Pro 500W power supply 12 GB Kingston RAM Nvidia GeForce 9800 GT graphics card My machine ran well for awhile. However, it started experiencing random lockups. These lockups are not X lockups, they are complete system freezes. The nic stops responding, the magic sysrq buttons won't work. The machine is dead. I first suspected RAM. Memtest86 didn't find anything, but I replaced the RAM anyway. Still, lockups. So I replaced the graphics card. Still, more lockups. They became more and more frequent and started to happen 2-3 times a day. So I replaced the motherboard and power supply in one fell swoop. Suddenly, no more lockups! Woohoo! Except, a week later, in the morning, the machine wouldn't wake up. I reset it, started it up, and the log files showed the last entry at around 11 pm the evening before. This has started occurring with more frequency...now just about every morning I come in, the machine is locked up, and has been since the night before. Yesterday, in the 3 weeks since I replaced the motherboard and power supply, the machine actually locked up on in in mid-work. This is the first time since replacing the two (MB and PS) that this happened while I was using it. All others occurred while I was away. I'm at a loss. Nothing is in syslog or message that would indicate a problem around the time of the lockup. Temps are good...I use lmsensors to monitor and have a script that writes the output to file every minute. They never get that high. The only thing I haven't replaced at this point is the case and the harddrives. I doubt either could be the cause. What would you do if you were in my shoes? Is there a troubleshooting approach I'm missing? For the record, all of the other machines, all eleven of them, don't have any problems. They're all running the same version of Ubuntu (Lucid) that I am. Thanks!

    Read the article

  • How should we serve files in a small bioinformatics cluster?

    - by cespinoza
    We have a small cluster of six ubuntu servers. We run bioinformatics analyses on these clusters. Each analysis takes about 24 hours to complete, each core i7 server can handle 2 at a time, takes as input about 5GB data and outputs about 10-25GB of data. We run dozens of these a week. The software is a hodgepodge of custom perl scripts and 3rd party sequence alignment software written in C/C++. Currently, files are served from two of the compute nodes (yes, we're using compute nodes as file servers)-- each node has 5 1TB sata drives mounted separately (no raid) and is pooled via glusterfs 2.0.1. They each have as 3 bonded intel ethernet pci gigabit ethernet cards, attached to a d-link DGS-1224T switch ($300 24 port consumer-level). We are not currently using jumbo frames (not sure why, actually). The two file-serving compute nodes are then mirrored via glusterfs. Each of the four other nodes mounts the files via glusterfs. The files are all large (4gb+), and are stored as bare files (no database/etc) if that matters. As you can imagine, this is a bit of a mess that grew organically without forethought and we want to improve it now that we're running out of space. Our analyses are I/O intensive and it is a bottle neck-- we're only getting 140mB/sec between the two fileservers, maybe 50mb/sec from the clients (which only have single NICs). We have a flexible budget which I can probably get up $5k or so. How should we spend our budget? We need at least 10TB of storage fast enough to serve all nodes. How fast/big does the cpu/memory of such a file server have to be? Should we use NFS, ATA over Ethernet, iSCSI, Glusterfs, or something else? Should we buy two or more servers and create some sort of storage cluster, or is 1 server enough for such a small number of nodes? Should we invest in faster NICs (say, PCI-express cards with multiple connectors)? The switch? Should we use raid, if so, hardware or software? and which raid (5, 6, 10, etc)? Any ideas appreciated. We're biologists, not IT gurus.

    Read the article

  • Looking for a new, free firewall (Sunbelt has a huge hole)

    - by Jason
    I've been using Sunbelt Personal Firewall v. 4.5 (previously Kerio). I've discovered that blocking Firefox connections in the configuration doesn't stop EXISTING Firefox connections. (See my post here yesterday http://superuser.com/questions/132625/sunbelt-firewall-4-5-wont-block-firefox) The "stop all traffic" may work on existing connections - but I'm done testing, as I need to be able to be selective, at any time. I was using the free version, so the "web filtering" option quit working after some time (mostly blocking ads and popups), but I didn't use that anyway. I used the last free version of Kerio before finally having to go to Sunbelt, because Kerio had an unfixed bug where you'd eventually get the BSOD and have to reset Kerio's configuration and start over (configure everything again). So I'm looking for a new Firewall. I don't like ZoneAlarm at all (no offense to all it's users that may be here - personal taste). I need the following: (Sunbelt has all these, except *) - 1. Be able to block in/out to localhost (trusted)/internet selectively for each application with a click (so there's 4 click boxes for each application) [*that effects everything immediately, regardless of what's already connected]. When a new application attempts a connection, you get an allow/deny/remember windows. - 2. Be able to easily set up filter rules for 'individual application'/'all applications,' by protocol, port/address (range), local, remote, in, out. [*Adding a filter rule also doesn't block existing connections in Sunbelt. That needs to work too.] - 3. Have an easy-to-get-to way to "stop all traffic" (like a right click option on the running icon in the task bar). - 4. Be able to set trusted/internet in/out block/allowed (4 things per item) for each of IGMP, ping, DNS, DHCP, VPN, and broadcasts. - 5. Define locahost as trusted/untrusted, define adapter connections as trusted/untrusted. - 6. Block incoming connetions during boot-up and shutdown. - 7. Show existing connections, including local & remote ip/port, protocol, current speed, total bytes transferred, and local ports opened for Listening. - 8. An Intrusion Prevention System which blocks (optionally select each one) known intrustions (long list). - 9. Block/allow applications from starting other applications (deny/allow/remember window). Wish list: A way of knowing what svchost.exe is doing - who is actually using it/calling it. I allowed it for localhost, and selectively allowed it for internet each time the allow/deny window came up. Thanks for any help/suggestions. (I'm using Windows XP SP3.)

    Read the article

  • How does an NTP host switch among the various modes?

    - by James A. Rosen
    The NTPv3 RFC describes five operating modes: Symmetric Active (1): A host operating in this mode sends periodic messages regardless of the reachability state or stratum of its peer. By operating in this mode the host announces its willingness to synchronize and be synchronized by the peer. Symmetric Passive (2): This type of association is ordinarily created upon arrival of a message from a peer operating in the symmetric active mode and persists only as long as the peer is reachable and operating at a stratum level less than or equal to the host; otherwise, the association is dissolved. However, the association will always persist until at least one message has been sent in reply. By operating in this mode the host announces its willingness to synchronize and be synchronized by the peer. Client (3): A host operating in this mode sends periodic messages regardless of the reachability state or stratum of its peer. By operating in this mode the host, usually a LAN workstation, announces its willingness to be synchronized by, but not to synchronize the peer. Server (4): This type of association is ordinarily created upon arrival of a client request message and exists only in order to reply to that request, after which the association is dissolved. By operating in this mode the host, usually a LAN time server, announces its willingness to synchronize, but not to be synchronized by the peer. Broadcast (5): A host operating in this mode sends periodic messages regardless of the reachability state or stratum of the peers. By operating in this mode the host, usually a LAN time server operating on a high-speed broadcast medium, announces its willingness to synchronize all of the peers, but not to be synchronized by any of them. It seems to me, though, that any host except a leaf node would probably be in several modes. For example, I might have a local area network with three NTP servers, each in Symmetric Active (1) mode with respect to one another. They would also each be clients (3) of one of the many public stratum two time servers. Lastly, they would all server as servers (4) to the many local clients. Is the point that they're only in a given mode for a moment during the synchronization? If so, how does a host know to switch? I'm only looking for enough depth here to discuss the issue in an educated manner, not to write a custom time server.

    Read the article

  • Slow WLAN file transfer between server and tablet

    - by user266985
    My file server is running Ubuntu 12.04 and I'm sharing files from it over samba. It is connected via gigabit ethernet. My desktop, running Windows 8.1, is also connected via gigabit ethernet. I can transfer files between the two and completely saturate that gigabit pipe. However, I just got a Surface Pro 2, and I'm trying to stream HD movies from my server to the device over WiFi. For some reason, I can't break much past 1.5MB/s transferring files over the network. I've tried streaming through XBMC and a standard file copy; no difference. To add the confusion, if I connect to my guest network and then use my VPN server (installed on the router) to access the file server, I get around 3.2MB/s. I've been running diagnostics to determine the root and I think I've found it but I have no idea what is causing it or how to fix it. Router: Asus RT-N66U Surface Pro 2 Network Card: Marvell Avastar 350N (Driver 19/09/2013 v14.69.24044.150) InSSIDer: Link Score: 100 Co-Channels: 0 Overlapping: 0 5GHz Network Channel: 48+44 iperf File Server as Server; Surface Pro 2 as Client - TCP Performance: Acceptable ------------------------------------------------------------ Server listening on TCP port 5001 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 4] local 192.168.0.90 port 5001 connected with 192.168.0.56 port 57367 [ ID] Interval Transfer Bandwidth [ 4] 0.0- 1.0 sec 10.1 MBytes 84.7 Mbits/sec [ 4] 1.0- 2.0 sec 10.4 MBytes 87.6 Mbits/sec [ 4] 2.0- 3.0 sec 10.6 MBytes 88.8 Mbits/sec [ 4] 3.0- 4.0 sec 10.7 MBytes 89.5 Mbits/sec [ 4] 4.0- 5.0 sec 10.1 MBytes 84.4 Mbits/sec [ 4] 5.0- 6.0 sec 10.2 MBytes 85.8 Mbits/sec [ 4] 6.0- 7.0 sec 7.04 MBytes 59.1 Mbits/sec [ 4] 7.0- 8.0 sec 10.8 MBytes 90.2 Mbits/sec [ 4] 8.0- 9.0 sec 10.6 MBytes 89.1 Mbits/sec [ 4] 9.0-10.0 sec 8.62 MBytes 72.3 Mbits/sec [ 4] 0.0-10.0 sec 99.2 MBytes 83.1 Mbits/sec iperf Surface Pro 2 as Server, File Server as Client Performance: Poor ------------------------------------------------------------ Client connecting to 192.168.0.56, TCP port 5001 TCP window size: 22.9 KByte (default) ------------------------------------------------------------ [ 3] local 192.168.0.90 port 40233 connected with 192.168.0.56 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0- 1.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 1.0- 2.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 2.0- 3.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 3.0- 4.0 sec 1.25 MBytes 10.5 Mbits/sec [ 3] 4.0- 5.0 sec 1.62 MBytes 13.6 Mbits/sec [ 3] 5.0- 6.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 6.0- 7.0 sec 1.38 MBytes 11.5 Mbits/sec [ 3] 7.0- 8.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 8.0- 9.0 sec 1.50 MBytes 12.6 Mbits/sec [ 3] 9.0-10.0 sec 1.62 MBytes 13.6 Mbits/sec [ 3] 0.0-10.1 sec 15.0 MBytes 12.4 Mbits/sec For some reason, it gets capped and I haven't got a clue why. Any suggestions? Edit: My link speed is reported as 270Mbps by Windows. I'm less than two metres from the router with a clear line of sight.

    Read the article

  • Network unreachable on Ubuntu guest after trying to set up a host only network on Virtualbox

    - by gkb0986
    I have a Mac OS X host and a bunch of guests including Ubuntu and Arch Linux. I was trying to set up a host-only network at eth1 to let me ssh into the system. But now eth0 isn't working properly either. Ubuntu can no longer connect to remote hosts or browse the internet. It tells me that the network is unreachable. What's gone wrong here? I've included some diagnostics below. $ifconfig lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:10968 errors:0 dropped:0 overruns:0 frame:0 TX packets:10968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:897264 (897.2 KB) TX bytes:897264 (897.2 KB) Other diagnostic commands and the output: $sudo lspci -n 00:00.0 0600: 8086:1237 (rev 02) 00:01.0 0601: 8086:7000 00:01.1 0101: 8086:7111 (rev 01) 00:02.0 0300: 80ee:beef 00:03.0 0200: 8086:100e (rev 02) 00:04.0 0880: 80ee:cafe 00:05.0 0401: 8086:2415 (rev 01) 00:06.0 0C03: 106B:003F 00:07.0 0680: 8086:7113 (REV 08) 00:0D.0 0106: 8086:2829 (REV 02) $sudo lshw -c network *-network DISABLED description: Ethernet interface product: 82540EM Gigabit Ethernet Controller vendor: Intel Corporation physical id: 3 bus info: pci@0000:00:03.0 logical name: eth0 version: 02 serial: 08:00:27:7d:22:df size: 1Gbit/s capacity: 1Gbit/s width: 32 bits clock: 66MHz capabilities: pm pcix bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=e1000 driverversion=7.3.21-k8-NAPI duplex=full firmware=N/A latency=64 link=no mingnt=255 multicast=yes port=twisted pair speed=1Gbit/s resources: irq:19 memory:f0000000-f001ffff ioport:d010(size=8) $lsmod Module Size Used by nls_utf8 12557 1 isofs 40257 1 vboxsf 43743 2 vesafb 13844 1 snd_intel8x0 38570 2 snd_ac97_codec 134869 1 snd_intel8x0 ac97_bus 12730 1 snd_ac97_codec snd_pcm 97275 2 snd_intel8x0,snd_ac97_codec snd_seq_midi 13324 0 snd_rawmidi 30748 1 snd_seq_midi snd_seq_midi_event 14899 1 snd_seq_midi rfcomm 47604 0 snd_seq 61929 2 snd_seq_midi,snd_seq_midi_event bnep 18281 2 bluetooth 180113 10 rfcomm,bnep ppdev 17113 0 psmouse 97519 0 snd_timer 29990 2 snd_pcm,snd_seq joydev 17693 0 snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq vboxvideo 12622 1 serio_raw 13211 0 snd 79041 11 snd_intel8x0,snd_ac97_codec,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device soundcore 15091 1 snd vboxguest 235498 7 vboxsf parport_pc 32866 0 drm 241971 2 vboxvideo i2c_piix4 13301 0 snd_page_alloc 18529 2 snd_intel8x0,snd_pcm mac_hid 13253 0 lp 17799 0 parport 46562 3 ppdev,parport_pc,lp usbhid 47238 0 hid 99636 1 usbhid e1000 108589 0

    Read the article

  • On ESXi, guest machines hang for significant intervals compared to real machines. How can I fix this?

    - by Tarbox
    This is ESXi version 5.0.0. We plan on upgrading to 5.5 eventually. I have four code profiles, two taken on a real, unvirtualized machine, two taken on a virtual machine. Ordering the list of subroutines by time spent in each one, the two real profiles are practically identical. The two virtual profiles are different from each other and from the real profiles: a subset of subroutines are taking a lot more time on the virtual machines, and the subset is different for each run. The two virtual profiles take a similar amount of time, which is 3 times the amount of time the real profiles take. This gross "how long does it take?" result is consistent after hundreds of tests across three different virtual machines on two different host machines -- the virtual machine is just slower. I've only the code profiling on the four, however. Here's the most guilty set of lines: This is the real machine: 8µs $text = '' unless defined $text; 1.48ms foreach ( split( "\n", $text ) ) { This is the first run on the virtual machine: 20.1ms $text = '' unless defined $text; 1.49ms foreach ( split( "\n", $text ) ) { This is the second run on the virtual machine: 6µs $text = '' unless defined $text; 21.9ms foreach ( split( "\n", $text ) ) { My WAG is that the VM is swapping out the thread and then swapping it back in, destroying some level of cache in the process, but these code profiles were taken when the vm in question was the only active vm on the host, so... what? What does that mean? The guest itself is under light load, this is a latency problem for my users rather than throughput. The host is also under a light load, if I knew what resources to assign where, I could do it without worrying about the cost. I've attempted to lock memory, reserve cpu, assign a restrictive affinity, and disable hyperthread sharing. They don't help, it still takes the VM 2-4x the amount of time to do the same thing as the real machine. The host the tests were run on is 6x2.50GHz, Intel Xeon E5-26400 w/ 16gigs of ram. The guest exhibits the same performance under a wide combination of settings. The real machine is 4x2.13GHz, Xeon E5506 w/ 2 gigs of ram. Thank you for all advice.

    Read the article

< Previous Page | 412 413 414 415 416 417 418 419 420 421 422 423  | Next Page >