Search Results

Search found 51448 results on 2058 pages for 'log files'.

Page 499/2058 | < Previous Page | 495 496 497 498 499 500 501 502 503 504 505 506  | Next Page >

  • Batch break up after call other batch file

    - by Sven Arno Jopen
    i have the problem, that my batch process breaking up each time after call a other batch file. The batch files are used to run a make process out from IBM Rhapsody. There convert the call from Rhapsody to the Visual Studio tools. So nmake will be called from the batch after make different settings. The scripts aren’t written completely from me, I only adapt theme to run under both windows architecture versions, x86 and x64. The first script (vs2005_make.bat) will be called from Rhapsody and run to the “call” statement. The second script (Vcvars_VisualStudio2005.bat) runs to the end. But the first script isn’t resume working, at this point the process break up without a error message. I'm not very familiar with batch files, this is the first time I make more than simple console commands in a batch file. So I hope I have given all information’s which needed, otherwise ask me. Here the start script (vs2005_make.bat): :: parameter 1 - Makefile which should be used :: parameter 2 - The make target mark @echo off IF "%2"=="" set target=all IF "%2"=="all" set target=all IF "%2"=="build" set target=all IF "%2"=="rebuild" set target=clean all IF "%2"=="clean" set target=clean set RegQry="HKLM\Hardware\Description\System\CentralProcessor\0" REG.exe Query %RegQry% > checkOS.txt Find /i "x86" < CheckOS.txt > StringCheck.txt IF %ERRORLEVEL%==0 ( set arch=x86 ) ELSE ( set arch=x64 ) call "%ProgramFiles%\IBM\Rhapsody752\Share\etc\Vcvars_VisualStudio2005.bat" %arch% IF %ERRORLEVEL%==0 ( set makeflags= nmake /nologo /S /F %1 %target% ) del checkOS.txt del StringCheck.txt exit and here the called script (Vcvars_VisualStudio2005.bat): :: param 1 - Processor architecture @echo off ECHO param 1 = %1 IF %1==x86 ( SET ProgrammPath=%ProgramFiles% ) ELSE IF %1==x64 ( SET ProgrammPath=%ProgramFiles(x86)% ) ELSE ( ECHO Unknowen architectur EXIT /B 1 ) SET VSINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8\Common7\IDE" SET VCINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8" SET FrameworkDir=C:\WINDOWS\Microsoft.NET\Framework SET FrameworkVersion=v2.0.50727 SET FrameworkSDKDir="%ProgrammPath%\Microsoft Visual Studio 8\SDK\v2.0" rem Root of Visual Studio common files. IF %VSINSTALLDIR%=="" GOTO Usage IF %VCINSTALLDIR%=="" SET VCINSTALLDIR=%VSINSTALLDIR% rem rem Root of Visual Studio ide installed files. rem SET DevEnvDir=%VSINSTALLDIR% rem rem Root of Visual C++ installed files. rem SET MSVCDir=%VCINSTALLDIR%\VC SET PATH=%DevEnvDir%;%MSVCDir%\BIN;%VCINSTALLDIR%\Common7\Tools;%VCINSTALLDIR%Common7 \Tools\bin\prerelease;%VCINSTALLDIR%\Common7\Tools\bin;%FrameworkSDKDir%\bin;%FrameworkDir%\%FrameworkVersion%;%PATH%; SET INCLUDE=%MSVCDir%\ATLMFC\INCLUDE;%MSVCDir%\INCLUDE;%MSVCDir%\PlatformSDK\include\gl;%MSVCDir%\PlatformSDK\include;%FrameworkSDKDir%\include;%INCLUDE% SET LIB=%MSVCDir%\ATLMFC\LIB;%MSVCDir%\LIB;%MSVCDir%\PlatformSDK\lib;%FrameworkSDKDir%\lib;%LIB% GOTO end :Usage ECHO. VSINSTALLDIR variable is not set. ECHO. ECHO SYNTAX: %0 GOTO end :end Here the console output, what I not understand here and find very suspicious is that after the “IF %ERRORLEVEL%” Statement in the first script all will be put out regardless the echo is set to off… Executing: "C:\Programme\IBM\Rhapsody752\Share\etc\vs2005_make.bat" Simulation.mak build IF %ERRORLEVEL%==0 ( Mehr? set arch=x86 Mehr? ) ELSE ( Mehr? set arch=x64 Mehr? ) call "%ProgramFiles%\IBM\Rhapsody752\Share\etc\Vcvars_VisualStudio2005.bat" %arch% :: param 1 - Processor architecture @echo off ECHO param 1 = %1 param 1 = x86 IF %1==x86 ( Mehr? SET ProgrammPath=%ProgramFiles% Mehr? ) ELSE IF %1==x64 ( Mehr? SET ProgrammPath=%ProgramFiles(x86)% Mehr? ) ELSE ( Mehr? ECHO Unknowen architectur Mehr? EXIT /B 1 Mehr? ) SET VSINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8\Common7\IDE" SET VCINSTALLDIR="%ProgrammPath%\Microsoft Visual Studio 8" SET FrameworkDir=C:\WINDOWS\Microsoft.NET\Framework SET FrameworkVersion=v2.0.50727 SET FrameworkSDKDir="%ProgrammPath%\Microsoft Visual Studio 8\SDK\v2.0" rem Root of Visual Studio common files. IF %VSINSTALLDIR%=="" GOTO Usage IF %VCINSTALLDIR%=="" SET VCINSTALLDIR=%VSINSTALLDIR% rem rem Root of Visual Studio ide installed files. rem SET DevEnvDir=%VSINSTALLDIR% rem rem Root of Visual C++ installed files. rem SET MSVCDir=%VCINSTALLDIR%\VC SET PATH=%DevEnvDir%;%MSVCDir%\BIN;%VCINSTALLDIR%\Common7\Tools;%VCINSTALLDIR%\Common7\Tools\bin\prerelease;%VCINSTALLDIR%\Common7\Tools\bin;%FrameworkSDKDir%\bin;%FrameworkDir%\%FrameworkVersion%;%PATH%; SET INCLUDE=%MSVCDir%\ATLMFC\INCLUDE;%MSVCDir%\INCLUDE;%MSVCDir%\PlatformSDK\include\gl;%MSVCDir%\PlatformSDK\include;%FrameworkSDKDir%\include;%INCLUDE% SET LIB=%MSVCDir%\ATLMFC\LIB;%MSVCDir%\LIB;%MSVCDir%\PlatformSDK\lib;%FrameworkSDKDir%\lib;%LIB% GOTO end Build Done I hope someone have an idea, i work now since two days and don't find the error... thanking you in anticipation. Note: The word “Mehr?” in the text output is german and means “more”. I don't know were it comes from and it is possible that it is a bad translation from the English output to german.

    Read the article

  • Python: some newbie questions on sys.stderr and using function as argument

    - by Cawas
    I'm just starting on Python and maybe I'm worrying too much too soon, but anyways... log = "/tmp/trefnoc.log" def logThis (text, display=""): msg = str(now.strftime("%Y-%m-%d %H:%M")) + " TREfNOC: " + text if display != None: print msg + display logfile = open(log, "a") logfile.write(msg + "\n") logfile.close() return msg def logThisAndExit (text, display=""): msg = logThis(text, display=None) sys.exit(msg + display) That is working, but I don't like how it looks. Is there a better way to write this (maybe with just 1 function) and is there any other thing I should be concerned under exiting? Now to some background... Sometimes I will call logThis just to log and display. Other times I want to call it and exit. Initially I was doing this: logThis ("ERROR. EXITING") sys.exit() Then I figured that wouldn't properly set the stderr, thus the current code shown on the top. My first idea was actually passing "sys.exit" as an argument, and defining just logThis ("ERROR. EXITING", call=sys.exit) defined as following (showing just the relevant differenced part): def logThis (text, display="", call=print): msg = str(now.strftime("%Y-%m-%d %H:%M")) + " TREfNOC: " + text call msg + display But that obviously didn't work. I think Python doesn't store functions inside variables. I couldn't (quickly) find anywhere if Python can have variables taking functions or not! Maybe using an eval function? I really always try to avoid them, tho. Sure I thought of using if instead of another def, but that wouldn't be any better or worst. Anyway, any thoughts?

    Read the article

  • Putting a versioned-but-not-via-source control project in source control

    - by Emilio
    I have some old code (an old but still maintained VB6 application) that from a source control point of view is the ultimate example of the plumber's plumbing (or cobbler's shoes). It's been version controlled by the approach of making a new directory for each version. Are there any major downsides to taking the following approach? Do the initial check-in of all files Erase all files from the working directory, then copy all files from the next version to the working directory Check them in Goto #2 until done Note that I have a general change log text file which I'd grab the comments from for each version I check in/commit. I don't have (or really care about at this point) comments on a per-file- basis. I don't really know at this point what files have changed between versions, and being lazy I figured I could avoid doing file compares between versions to find out, so that's why I'm taking the approach above. Not to mention that erasing all the files first allows file deletions to be detected. I specifically haven't mentioned which version control tool I'm using since I'm hoping (also assuming, but maybe very incorrectly) that the answer is fairly independent. When I use terms like "check-in" I use them in the general sense, not specific to a tool.

    Read the article

  • No Source available

    - by Eric
    I am not sure what happened or if I did anything.. Now anytime I try and debug it says no source available on all BCL stuff For example, on a debug.print I get that message with Locating source for 'f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs'. Checksum: MD5 {40 74 18 44 a8 15 28 2e 54 75 5e 40 d1 5f 6a 0} The file 'f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs' does not exist. Looking in script documents for 'f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs'... Looking in the projects for 'f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs'. The file was not found in a project. Looking in directory 'C:\Program Files\Microsoft Visual Studio 10.0\VC\crt\src\'... Looking in directory 'C:\Program Files\Microsoft Visual Studio 10.0\VC\atlmfc\src\mfc\'... Looking in directory 'C:\Program Files\Microsoft Visual Studio 10.0\VC\atlmfc\src\atl\'... Looking in directory 'C:\Program Files\Microsoft Visual Studio 10.0\VC\atlmfc\include\'... The debug source files settings for the active solution indicate that the debugger will not ask the user to find the file: f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs. The debugger could not locate the source file 'f:\dd\ndp\fx\src\CompMod\System\Diagnostics\Debug.cs'. This happens all the time now and I 1. Don't have an F: 2. Enable .net framework source stepping is unchecked Is there some other sneaky setting to make these messages go away? Regards _Eric

    Read the article

  • How do I connect to SDF on a Mobile device from desktop application?

    - by pitprog
    C# WinForms .Net 3.5 to SQL CE 3.5 on Mobile 6.1 Device I'd like to make a connection from a desktop application to a SDF database on my Windows Mobile device while it's connected via ActiveSync. Visual Studio lets me create a Data Connection to my device. The connections tests OK and I can view the data in the database using Visual Studio. I then create a form and try to fill a DataGridView. When I run the program I get an error that the path to the data base is not valid. How am I supposed to specify the Mobile device path in the connection string? In my App.Config, I've tried variations on the path, but none of them work: connectionString="Data Source=Mobile Device\Program Files\SqlCeViaActiveSync\Orders.sdf" connectionString="Data Source=\Mobile Device\Program Files\SqlCeViaActiveSync\Orders.sdf" connectionString="Data Source=Program Files\SqlCeViaActiveSync\Orders.sdf" connectionString="Data Source=\Program Files\SqlCeViaActiveSync\Orders.sdf" The full connection string section looks like this: <connectionStrings> <add name="SqlCeViaActiveSync.Properties.Settings.OrdersConnectionString" connectionString="Data Source=Mobile Device\Program Files\SqlCeViaActiveSync\Orders.sdf" providerName="Microsoft.SqlServerCe.Client.3.5" /> </connectionStrings> Also, I did make a reference to Microsoft.SqlServerCe.Client, as I found a few articles that mentioned it was necessary. Can anyone point me to some recent articles/samples or let me know what I'm doing wrong? Thanks!

    Read the article

  • mysql backup and restore from ib_logfile failure

    - by i need help
    Here's the case: After computer being hacked, we are in a rush to backup all data out to other computer. As a result, the mysql databases are not backup out as sql statement. What we have done is backup out all the physical files/folders in the C drive to new computer. Eg: C:\Program Files\MySQL\MySQL Server 4.1\data In this case, all data for mysql are inside unreadable file. Inside data folder consist of files like ib_logfile0, ib_logfile1, but not ib_data1 All database's table structure format are inside each respective folder. (Some folder have .frm, .opt) (some other folder have .frm, .myd, .myi) How can I retrieve back the data from the database in a new computer? I tried to install the same mysql version(4.1) at new computer, then replace all backup files inside data folder into this mysql in new computer. Then restart mysql service. When I restart, it fail: Could not start mysql service on local computer. error 1067: process terminated unexpectedly. Error log showing: InnoDB: The first specified data file .\ibdata1 did not exist: InnoDB: a new database to be created! 090930 10:24:49 InnoDB: Setting file .\ibdata1 size to 10 MB InnoDB: Database physically writes the file full: wait... InnoDB: Error: log file .\ib_logfile0 is of different size 0 87031808 bytes InnoDB: than specified in the .cnf file 0 25165824 bytes! 090930 10:24:49 [ERROR] Can't init databases 090930 10:24:49 [ERROR] Aborting 090930 10:24:49 [Note] C:\Program Files\MySQL\MySQL Server 4.1\bin\mysqld-nt: Shutdown complete

    Read the article

  • .NET projects build automation with NAnt/MSBuild + SVN

    - by petr k.
    Hi everyone, for quite a while now, I've been trying to figure out how to setup an automated build process at our shop. I've read many posts and guides on this matter and none of them really fits my specifics needs. My SVN repository is laid out as follows \projects \projectA (a product) \tags \1.0.0.1 \1.0.0.2 ... \trunk \src \proj1 (a VS C# project) \proj2 \documentation Then I have a network share, with a folder for each project (product), which in turn contains the binaries, written documentation and the generated API documentation (via NDoc - each project may have an .ndoc file in the repository) for every historical version (from the tags SVN folder) and for the latest version as well (from the trunk). Basically, what I want to do in a scheduled batch build are these steps: examine the project's SVN folder and identify tags not present in the network share for each of these tags check out the tag folder build (with Release config) copy the resulting binaries to the network share search for .ndoc files generate CHM files via NDoc copy the resulting CHM files to the network share do the same as in 2., but for the HEAD revision of trunk Now, the trouble is, I have no idea where to start. I do not keep .sln files in the repository, but I am able to replace these with MSBuild files which in turn build the C# projects belonging to the specific product. I guess the most troubling part is the examination of the repository for tags which have not been processed yet - i.e. searching the tags and comparing them to a project's directory structure on the network share. I have no idea how to do that in any of the build tools (NAnt, MSBuild). Could you please provide me with some pointers on how to approach this task as a whole and in detail as well? I do not care if I use NAnt, MSBuild, or both. I am aware that this might be rather complex, but every idea and NAnt/MSBuild snippet will be a great help. Thanks in advance.

    Read the article

  • Visual Studio 2008 - Add Reference

    - by James Sun
    When adding a DLL as a reference to an ASP.Net project, VS2008 adds several files to the bin directory. If the DLL is called foo.dll, VS2008 adds foo.dll.refresh, foo.pdb and foo.xml. I know what foo.dll is :-), why does VS2008 add the other three files? What do those three files do? Can I delete them? Do they need to be added in source control?

    Read the article

  • Sending data through POST request from a node.js server to a node.js server

    - by Masiar
    I'm trying to send data through a POST request from a node.js server to another node.js server. What I do in the "client" node.js is the following: var options = { host: 'my.url', port: 80, path: '/login', method: 'POST' }; var req = http.request(options, function(res){ console.log('status: ' + res.statusCode); console.log('headers: ' + JSON.stringify(res.headers)); res.setEncoding('utf8'); res.on('data', function(chunk){ console.log("body: " + chunk); }); }); req.on('error', function(e) { console.log('problem with request: ' + e.message); }); // write data to request body req.write('data\n'); req.write('data\n'); req.end(); This chunk is taken more or less from the node.js website so it should be correct. The only thing I don't see is how to include username and password in the options variable to actually login. This is how I deal with the data in the server node.js (I use express): app.post('/login', function(req, res){ var user = {}; user.username = req.body.username; user.password = req.body.password; ... }); How can I add those username and password fields to the options variable to have it logged in? Thanks

    Read the article

  • Character Encoding, UTF or ANSI?

    - by Paulocoghi
    I'm using Eclipse in Ubuntu to edit PHP files. But, unfortunately, some of these PHP files were created in Notepad++ in Windows XP, with ANSI encoding defined. Also, these files generates HTML codes with charset=ISO-8859-1. When I configured Eclipse to ISO-8859-1, many special characters were lost and changed to '???', and when I try to save a file with ISO enconding, Eclipse displays an error that was not possible to save the file because some characters aren't compatible with the charset. How can I save these files without changing the encoding, or how can I change the encoding without lose characters.

    Read the article

  • SQL Server 08 Express error when connecting to localhost - "Timeout expired". Works with ::1 or 127.0.0.1

    - by Adam A
    EDIT New info: Navigating to localhost:1434 in Chrome gives me an "ERR_EMPTY_RESPONSE", while other ports give me an "Oops! This link appears to be broken". So it seems to binding ok there? So here's my setup so far: I've configured Windows Firewall to allow TCP on 1433 and UDP on 1434. I've set up SQL Server to use any IP on Port 1433 (using the SQL Server Configuration Manager). My hosts file contains the default entries ("127.0.0.1 localhost" and "::1 localhost"). I sometimes have a debug session of Visual Web Developer running a webserver, but it's on a specific port (localhost:5XXXX). What I've tried: I CAN ping localhost in a cmd prompt. I CAN connect to the database through SSMS if I specify 127.0.0.1 or ::1 as the server name. I CAN'T connect to the database through SSMS (or ADO.NET) if I specify localhost as the server name. I've tried both Windows and SQL Authentication The error I get is the standard Can't connect to localhost. Additional Information -- Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding. (Microsoft Sql Server) Other considerations: Stopping the Visual Web Developer web server from the taskbar doesn't affect the sql problem. The SQL error log says that it's listening on some piped name url at start up (I don't see how this would affect localhost but not 127.0.0.1 though). I could probably just use 127.0.0.1 everywhere, but it scares me that localhost isn't working and I'd like to figure out why. I'm not much of a networking or sql server guy so I'm stuck. If you want me to try anything to help diagnose just put it in a comment and I'll give it a go. Netstat results: Setting SDK environment relative to C:\Program Files\Microsoft SDKs\Windows\v6.1 Targeting Windows Server 2008 x86 DEBUG C:\Program Files\Microsoft SDKs\Windows\v6.1netstat -ano | findstr 1434 UDP 0.0.0.0:1434 *:* 6868 UDP [::]:1434 *:* 6868 C:\Program Files\Microsoft SDKs\Windows\v6.1netstat -ano | findstr 1433 TCP 0.0.0.0:1433 0.0.0.0:0 LISTENING 2268 TCP 127.0.0.1:1433 127.0.0.1:50758 ESTABLISHED 2268 TCP 127.0.0.1:50758 127.0.0.1:1433 ESTABLISHED 5008 TCP [::]:1433 [::]:0 LISTENING 2268 TCP [::1]:1433 [::1]:51202 ESTABLISHED 2268 TCP [::1]:1433 [::1]:51616 ESTABLISHED 2268 TCP [::1]:51202 [::1]:1433 ESTABLISHED 5008 TCP [::1]:51616 [::1]:1433 ESTABLISHED 5008 C:\Program Files\Microsoft SDKs\Windows\v6.1 SQL Server Log File: In case it helps 2010-01-30 12:58:59.01 Server Microsoft SQL Server 2008 (SP1) - 10.0.2531.0 (Intel X86) Mar 29 2009 10:27:29 Copyright (c) 1988-2008 Microsoft Corporation Express Edition on Windows NT 6.0 (Build 6002: Service Pack 2) 2010-01-30 12:58:59.01 Server (c) 2005 Microsoft Corporation. 2010-01-30 12:58:59.01 Server All rights reserved. 2010-01-30 12:58:59.01 Server Server process ID is 2268. 2010-01-30 12:58:59.01 Server System Manufacturer: 'Dell Inc.', System Model: 'Inspiron 1545'. 2010-01-30 12:58:59.01 Server Authentication mode is MIXED. 2010-01-30 12:58:59.02 Server Logging SQL Server messages in file 'c:\Program Files\Microsoft SQL Server\MSSQL10.SQLEXPRESS\MSSQL\Log\ERRORLOG'. 2010-01-30 12:58:59.02 Server This instance of SQL Server last reported using a process ID of 7396 at 1/30/2010 12:57:38 PM (local) 1/30/2010 5:57:38 PM (UTC). This is an informational message only; no user action is required. 2010-01-30 12:58:59.02 Server Registry startup parameters: -d c:\Program Files\Microsoft SQL Server\MSSQL10.SQLEXPRESS\MSSQL\DATA\master.mdf -e c:\Program Files\Microsoft SQL Server\MSSQL10.SQLEXPRESS\MSSQL\Log\ERRORLOG -l c:\Program Files\Microsoft SQL Server\MSSQL10.SQLEXPRESS\MSSQL\DATA\mastlog.ldf 2010-01-30 12:58:59.02 Server SQL Server is starting at normal priority base (=7). This is an informational message only. No user action is required. 2010-01-30 12:58:59.02 Server Detected 2 CPUs. This is an informational message; no user action is required. 2010-01-30 12:58:59.08 Server Using dynamic lock allocation. Initial allocation of 2500 Lock blocks and 5000 Lock Owner blocks per node. This is an informational message only. No user action is required. 2010-01-30 12:58:59.17 Server Node configuration: node 0: CPU mask: 0x00000003 Active CPU mask: 0x00000003. This message provides a description of the NUMA configuration for this computer. This is an informational message only. No user action is required. 2010-01-30 12:58:59.30 spid7s Starting up database 'master'. 2010-01-30 12:58:59.41 spid7s Recovery is writing a checkpoint in database 'master' (1). This is an informational message only. No user action is required. 2010-01-30 12:58:59.67 spid7s FILESTREAM: effective level = 0, configured level = 0, file system access share name = 'SQLEXPRESS'. 2010-01-30 12:58:59.92 spid7s SQL Trace ID 1 was started by login "sa". 2010-01-30 12:58:59.94 spid7s Starting up database 'mssqlsystemresource'. 2010-01-30 12:58:59.95 spid7s The resource database build version is 10.00.2531. This is an informational message only. No user action is required. 2010-01-30 12:59:00.82 spid7s Server name is 'DELL\SQLEXPRESS'. This is an informational message only. No user action is required. 2010-01-30 12:59:00.83 Server A self-generated certificate was successfully loaded for encryption. 2010-01-30 12:59:00.84 Server Server is listening on [ 'any' 1433]. 2010-01-30 12:59:00.84 Server Server is listening on [ 'any' 1433]. 2010-01-30 12:59:00.84 spid10s Starting up database 'model'. 2010-01-30 12:59:00.85 Server Server local connection provider is ready to accept connection on [ \\.\pipe\SQLLocal\SQLEXPRESS ]. 2010-01-30 12:59:00.86 Server Server local connection provider is ready to accept connection on [ \\.\pipe\MSSQL$SQLEXPRESS\sql\query ]. 2010-01-30 12:59:00.86 Server Dedicated administrator connection support was not started because it is disabled on this edition of SQL Server. If you want to use a dedicated administrator connection, restart SQL Server using the trace flag 7806. This is an informational message only. No user action is required. 2010-01-30 12:59:00.87 Server The SQL Server Network Interface library could not register the Service Principal Name (SPN) for the SQL Server service. Error: 0x54b, state: 3. Failure to register an SPN may cause integrated authentication to fall back to NTLM instead of Kerberos. This is an informational message. Further action is only required if Kerberos authentication is required by authentication policies. 2010-01-30 12:59:00.87 spid7s Informational: No full-text supported languages found. 2010-01-30 12:59:00.87 Server SQL Server is now ready for client connections. This is an informational message; no user action is required. 2010-01-30 12:59:00.91 spid7s Starting up database 'msdb'. 2010-01-30 12:59:01.21 spid10s Clearing tempdb database. 2010-01-30 12:59:02.78 spid10s Starting up database 'tempdb'. 2010-01-30 12:59:03.30 spid13s The Service Broker protocol transport is disabled or not configured. 2010-01-30 12:59:03.30 spid13s The Database Mirroring protocol transport is disabled or not configured. 2010-01-30 12:59:03.31 spid7s Recovery is complete. This is an informational message only. No user action is required. 2010-01-30 12:59:03.31 spid13s Service Broker manager has started.

    Read the article

  • How to mask tilde (~) character in C# MVC routing table?

    - by AC
    I'm moving my home-baked web site to MVC and got the trouble with url routing. The site already serves several links that contain tilde (~) character in the path; something like http://.../~files/... http://.../~ws/... and I want each of them are handled by separate controller, like filesController, wsController, so my route table looks like routes.MapRoute( "files", "~files/{*prms}", new { controller = "files", action = "index", prms = "" } ); routes.MapRoute( "ws", "~ws/{*prms}", new { controller = "ws", action = "index", prms = "" } ); ... but when I try to get the result I got the error saying "The route URL cannot start with a '/' or '~' character and it cannot contain a '?' character." As I understand those characters have the special meaning in ASP.net but is it possible to mask them somehow, at least tilde? Should I parse and route requests like this myself? What the best practice to handle urls like this? Thanks!

    Read the article

  • log4j additivity, category logging level and appender threshold

    - by GBa
    I'm having troubles understanding the relation between additivity, category logging level and appender threshold... here's the scenario (my log4j.properties file): log4j.category.GeneralPurpose.classTypes=INFO, webAppLogger log4j.additivity.GeneralPurpose.classTypes=true log4j.category.GeneralPurpose=ERROR, defaultLogger log4j.additivity.GeneralPurpose=false log4j.appender.webAppLogger=org.apache.log4j.RollingFileAppender log4j.appender.webAppLogger.File=webapps/someWebApp/logs/webApp.log log4j.appender.webAppLogger.MaxFileSize=3000KB log4j.appender.webAppLogger.MaxBackupIndex=10 log4j.appender.webAppLogger.layout=org.apache.log4j.PatternLayout log4j.appender.webAppLogger.layout.ConversionPattern=%d [%t] (%F:%L) %-5p - %m%n log4j.appender.webAppLogger.Encoding=UTF-8 log4j.appender.defaultLogger=org.apache.log4j.RollingFileAppender log4j.appender.defaultLogger.File=logs/server.log log4j.appender.defaultLogger.MaxFileSize=3000KB log4j.appender.defaultLogger.MaxBackupIndex=10 log4j.appender.defaultLogger.layout=org.apache.log4j.PatternLayout log4j.appender.defaultLogger.layout.ConversionPattern=%d [%t] (%F:%L) %-5p - %m%n log4j.appender.defaultLogger.Encoding=UTF-8 insights: category GeneralPurpose.classTypes is INFO category GeneralPurpose.classTypes has additivity TRUE category GeneralPurpose is ERROR category GeneralPurpose has additivity FALSE with the current configuration I would have assumed that INFO messages sent to category GeneralPurpose.classTypes.* would be only logged to webAppLogger since the parent logger (cateogry) is set with ERROR level logging. However, this is not the case, the message is logged twice (one in each log file). Looks like the ERROR logging level for the parent category is not taken into consideration when the event is sent as part of additivity... is my observation correct or am I missing something ? how should I alter the configuration in order to achieve only ERROR level loggings in server.log ? thanks, GBa.

    Read the article

  • SMO restore of SQL database doesn't overwrite

    - by Tom H.
    I'm trying to restore a database from a backup file using SMO. If the database does not already exist then it works fine. However, if the database already exists then I get no errors, but the database is not overwritten. The "restore" process still takes just as long, so it looks like it's working and doing a restore, but in the end the database has not changed. I'm doing this in Powershell using SMO. The code is a bit long, but I've included it below. You'll notice that I do set $restore.ReplaceDatabase = $true. Also, I use a try-catch block and report on any errors (I hope), but none are returned. Any obvious mistakes? Is it possible that I'm not reporting some error and it's being hidden from me? Thanks for any help or advice that you can give! function Invoke-SqlRestore { param( [string]$backup_file_name, [string]$server_name, [string]$database_name, [switch]$norecovery=$false ) # Get a new connection to the server [Microsoft.SqlServer.Management.Smo.Server]$server = New-SMOconnection -server_name $server_name Write-Host "Starting restore to $database_name on $server_name." Try { $backup_device = New-Object("Microsoft.SqlServer.Management.Smo.BackupDeviceItem") ($backup_file_name, "File") # Get local paths to the Database and Log file locations If ($server.Settings.DefaultFile.Length -eq 0) {$database_path = $server.Information.MasterDBPath } Else { $database_path = $server.Settings.DefaultFile} If ($server.Settings.DefaultLog.Length -eq 0 ) {$database_log_path = $server.Information.MasterDBLogPath } Else { $database_log_path = $server.Settings.DefaultLog} # Load up the Restore object settings $restore = New-Object Microsoft.SqlServer.Management.Smo.Restore $restore.Action = 'Database' $restore.Database = $database_name $restore.ReplaceDatabase = $true if ($norecovery.IsPresent) { $restore.NoRecovery = $true } Else { $restore.Norecovery = $false } $restore.Devices.Add($backup_device) # Get information from the backup file $restore_details = $restore.ReadBackupHeader($server) $data_files = $restore.ReadFileList($server) # Restore all backup files ForEach ($data_row in $data_files) { $logical_name = $data_row.LogicalName $physical_name = Get-FileName -path $data_row.PhysicalName $restore_data = New-Object("Microsoft.SqlServer.Management.Smo.RelocateFile") $restore_data.LogicalFileName = $logical_name if ($data_row.Type -eq "D") { # Restore Data file $restore_data.PhysicalFileName = $database_path + "\" + $physical_name } Else { # Restore Log file $restore_data.PhysicalFileName = $database_log_path + "\" + $physical_name } [Void]$restore.RelocateFiles.Add($restore_data) } $restore.SqlRestore($server) # If there are two files, assume the next is a Log if ($restore_details.Rows.Count -gt 1) { $restore.Action = [Microsoft.SqlServer.Management.Smo.RestoreActionType]::Log $restore.FileNumber = 2 $restore.SqlRestore($server) } } Catch { $ex = $_.Exception Write-Output $ex.message $ex = $ex.InnerException while ($ex.InnerException) { Write-Output $ex.InnerException.message $ex = $ex.InnerException } Throw $ex } Finally { $server.ConnectionContext.Disconnect() } Write-Host "Restore ended without any errors." }

    Read the article

  • PHP - format bytes to kilobytes, megabytes, gigabytes

    - by pygorex1
    Scenario: the size of various files are stored in a database as bytes. What's the best way to format this size info to kilobytes, megabytes and gigabytes? For instance I have an MP3 that Ubuntu displays as "5.2 MB (5445632 bytes)". How would I display this on a web page as "5.2 MB" AND have files less than one megabyte display as KB and files one gigabyte and above display as GB?

    Read the article

  • File upload permission problem IIS 7

    - by krish
    I am unable to upload files to website hosted under IIS7. I have already given write permissions to "IUSR_websitename" and set the property in web.config also. I am able to upload files with out log in to application at the time of user registration. But once log in to application, if I upload files, it is giving "Access denied" error. Please help me.

    Read the article

  • Titanium won't run iPhone/Android Emulator

    - by BeOliveira
    I just installed Titanium SDK (1.5.1) and all the Android SDKs. Also, I already have iPhone SDK 4.2 installed. I downloaded KitchenSink and imported it into Titanium but whenever I try to run it on iPhone Emulator, I get this error: [INFO] One moment, building ... [INFO] Titanium SDK version: 1.5.1 [INFO] iPhone Device family: iphone [INFO] iPhone SDK version: 4.0 [INFO] Detected compiler plugin: ti.log/0.1 [INFO] Compiler plugin loaded and working for ios [INFO] Performing clean build [INFO] Compiling localization files [INFO] Detected custom font: comic_zine_ot.otf [ERROR] Error: Traceback (most recent call last): File "/Library/Application Support/Titanium/mobilesdk/osx/1.5.1/iphone/builder.py", line 1003, in main execute_xcode("iphonesimulator%s" % iphone_version,["GCC_PREPROCESSOR_DEFINITIONS=LOG__ID=%s DEPLOYTYPE=development TI_DEVELOPMENT=1 DEBUG=1 TI_VERSION=%s" % (log_id,sdk_version)],False) File "/Library/Application Support/Titanium/mobilesdk/osx/1.5.1/iphone/builder.py", line 925, in execute_xcode output = run.run(args,False,False,o) File "/Library/Application Support/Titanium/mobilesdk/osx/1.5.1/iphone/run.py", line 31, in run sys.exit(rc) SystemExit: 1 And for Android, it runs the OS but not the KitchenSink app, here's the log: [INFO] Launching Android emulator...one moment [INFO] Building KitchenSink for Android ... one moment [INFO] plugin=/Library/Application Support/Titanium/plugins/ti.log/0.1/plugin.py [INFO] Detected compiler plugin: ti.log/0.1 [INFO] Compiler plugin loaded and working for android [INFO] Titanium SDK version: 1.5.1 (12/16/10 16:25 16bbb92) [INFO] Waiting for the Android Emulator to become available [ERROR] Timed out waiting for android.process.acore [INFO] Copying project resources.. [INFO] Detected tiapp.xml change, forcing full re-build... [INFO] Compiling Javascript Resources ... [INFO] Copying platform-specific files ... [INFO] Compiling localization files [INFO] Compiling Android Resources... This could take some time Any ideas on how to get Titanium to work?

    Read the article

  • Programatically find TFS changes since last good build

    - by abigblackman
    I have several branches in TFS (dev, test, stage) and when I merge changes into the test branch I want the automated build and deploy script to find all the updated SQL files and deploy them to the test database. I thought I could do this by finding all the changesets associated with the build since the last good build, finding all the sql files in the changesets and deploying them. However I don't seem to be having the changeset associated with the build for some reason so my question is twofold: 1) How do I ensure that a changeset is associated with a particular build? 2) How can I get a list of files that have changed in the branch since the last good build? I have the last successfully built build but I'm unsure how to get the files without checking the changesets (which as mentioned above are not associated with the build!)

    Read the article

  • Eclipse: Synchronizing project on Thumbdrive with PC

    - by Thomas Matthews
    I have a thumb drive (memory stick, flash drive, etc.) on which I use for my projects when I am away from my home PC. Currently I am accessing my Eclipse project directly from my thumb drive when connected to my PC. I would like to copy my files to the PC, develop on the PC, then "synchronize" with the thumb drive (update files on the thumb drive). I also need the reverse process too: synchronize thumb drive files with files on PC. I have looked at the FileSync plugin, but it specifically says it is one-way. How can I synchronize my Eclipse project both directions (PC to thumb drive and thumb drive to PC) on demand (I don't need this done automagically)?

    Read the article

  • Enumerating .NET assembly resources at runtime

    - by Alex_P
    I have a resource assembly with image files in it that are built using Resource or Content build action. This makes these files accessible using the Uris. However I cannot find the way to enumerate such resources. If I set the build action to Embedded Resource it becomes possible to enumerate the files with the following code: string[] resources = Assembly.GetExecutingAssembly().GetManifestResourceNames(); but it in turn makes these files inaccessible using Uris. The question is - how to enumerate resources that are compiled with either Resource or Content build action? NOTE: As Thomas Levesque pointed out it is possible to enumerate such resources by leveraging the AssemblyAssociatedContentFileAttribute, but it seems to only work for WPF Application assemblies and not for class library ones. So the question is still open.

    Read the article

  • Static libpng link with visual studio 2010

    - by Sanctus2099
    Hey guys. I'm trying to add PNG support to my application and thus I want to include libpng. I know it needs zlib and thus I downloaded that as well. I went into the png folder/projects/vstudio and I opened the solution. I compiled it and it went just fine. I added some headers from it into my application and I copied the lib files. My program is a dll written in c++ which is later used from C#. When I run it in C# it complains about not finding my dll (tough if I remove the png part it works fine). I've had this problem before and it usually means a dll dependency is wrong. Now... libpng compiled both some .lib files and some .dll files. The dll files are bigger. My only guess is that it needs the dll files as well but I've seen that people can link to libpng without a dll. So my questions is: How can I compile libpng(and zlib for that instance) into just static libraries and how can I include those in my projects? I've searched around the internet and I couldn't find anything useful.

    Read the article

  • Checking existence of file types via extensions bash.

    - by Tommy
    Hi, I need to test if various file types exist in a directory. I've tried $ [ -f *.$fileext] where fileext is the file extension but that does not seem to work. Both of these methods work function checkext() { fileext=$1 ls *.$fileext>/dev/null 2>&1 if [ $? -eq 0 ] then echo "We have $fileext files!" else echo "We don't have any $fileext files!" fi } and function checkext2() { extention=$1 filescheck=(`ls *.$1`) len=${#filescheck[*]} if [ $len -gt 0 ] then echo "We have $extention files!" else if [ $len -eq 0 ] then echo "We don't have any $extention files!" else echo "Error" fi fi } The second method is less tidy as any ls error is shown so I prefer method 1. Could people please suggest any improvements, more elegant solutions e.t.c

    Read the article

  • GUI to add a .props file to a VS 2010 project?

    - by jwfearn
    Visual Studio 2010 has no longer uses .vsprops files and instead uses .props files. To add a .vsprops file to a Visual Studio 2008 project, one could right-click the project icon in the Solution Explorer panel, choose Properties, go to the Configuration Properties | General section, and modify the Inherited Project Property Sheets property to contain a list of .vsprops paths. One could also modify the Visual Studio 2008 project file directly. Is there a way in the Visual Studio 2010 GUI to add .props files to a project? The Inherited Project Property Sheets property seems to have been removed. If manual editing of the project file is the only way to include .props files, where can one find documentation on doing it?

    Read the article

  • PartCover 2.5.3 win 7 x64

    - by user329814
    Could you tell me how you got PartCover running with VS2008 and win 7 x64? Based on this post http://stackoverflow.com/questions/256287/how-do-i-run-partcover-in-x64-windows, I ran c:\Program Files (x86)\Gubka Bob\PartCover .NET 2.3>CorFlags.exe PartCover.exe / 32BIT+ /Force with result Microsoft (R) .NET Framework CorFlags Conversion Tool. Version 3.5.21022.8 Copyright (c) Microsoft Corporation. All rights reserved. corflags : warning CF011 : The specified file is strong name signed. Using /Force will invalidate the signature of this image and will require the assembly to be resigned. and c:\Program Files (x86)\NUnit 2.5.2\bin\net-2.0>CorFlags.exe nunit.exe /32BIT+ /Force with result Microsoft (R) .NET Framework CorFlags Conversion Tool. Version 3.5.21022.8 Copyright (c) Microsoft Corporation. All rights reserved. Also, based on my discussion http://stackoverflow.com/questions/2546340/using-partcover-2-3-with-net-4-0-runtime/2964333#2964333, I also tried to use the x86 version of NUnit What I'm trying to run coverage for is the c# money sample for NUnit 2.5.2 I get the same System.Threading.ThreadInterruptedException --- System.Runtime.InteropServices.COMException (0x80040153): Retrieving the COM class factory for component with CLSID {FB20430E-CDC9-45D7-8453-272268002E08} failed due to the following error: 80040153 Thank you Edit: same thing with PartCover 2.2 My settings: exe file: C:\Program Files (x86)\NUnit 2.5.2\bin\net-2.0\nunit-console-x86.exe working dir: c:\Program Files (x86)\NUnit 2.5.2\samples\csharp\money\ work arg: /config=c:\Program Files (x86)\NUnit 2.5.2\samples\csharp\money\cs-money.csproj rules: +[]

    Read the article

  • What is the fastest way to unzip textfiles in Matlab during a function?

    - by Paul
    Hello all, I would like to scan text of textfiles in Matlab with the textscan function. Before I can open the textfile with fid = fopen('C:\path'), I need to unzip the files first. The files have the extension: *.gz There are thousands of files which I need to analyze and high performance is important. I have two ideas: (1) Use an external program an call it from the command line in Matlab (2) Use a Matlab 'zip'toolbox. I have heard of gunzip, but don't know about its performance. Does anyone knows a way to unzip these files as quick as possible from within Matlab? Thanks!

    Read the article

< Previous Page | 495 496 497 498 499 500 501 502 503 504 505 506  | Next Page >