Search Results

Search found 19908 results on 797 pages for 'bit ly'.

Page 704/797 | < Previous Page | 700 701 702 703 704 705 706 707 708 709 710 711  | Next Page >

  • Growing Talent

    The subtitle of Daniel Coyles intriguing book The Talent Code is Greatness Isnt Born. Its Grown. Heres How. The Talent Code proceeds to layout a theory of how expertise can be cultivated through specific practices that encourage the growth of myelin in the brain. Myelin is a material that is produced and wraps around heavily used circuits in the brain, making them more efficient. Coyle uses an analogy that geeks will appreciate. When a circuit in the brain is used a lot (i.e. a specific action is repeated), the myelin insulates that circuit, increasing its bandwidth from telephone over copper to high speed broadband. This leads to the funny phenomenon of effortless expertise. Although highly skilled, the best players make it look easy. Coyle provides some biological backing for the long held theory that it takes 10,000 hours of practice to achieve mastery over a given subject. 10,000 hours or 10 years, as in, Teach Yourself Programming in Ten Years and others. However, it is not just that more hours equals more mastery. The other factors that Coyle identifies includes deep practice, practice which crucially involves drills that are challenging without being impossible. Another way to put it is that every day you spend doing only tasks you find monotonous and automatic, you are literally stagnating your brains development! Perhaps Coyles subtitle, needs one more phrase, Greatness Isnt Born. Its Grown. Heres How. And oh yeah, its not easy. Challenging yourself, continuing to persist in the face of repeated failures, practicing every day is not easy. As consultants, we sell our expertise, so it makes sense that we plan projects so that people can play to their strengths. At the same time, an important part of our culture is constant improvement, challenging yourself to be better. And the balancing contest ensues. I just finished working on a proof of concept (POC) we did for a project we are bidding on. Completely time boxed, so our team naturally split responsibilities amongst ourselves according to who was better at what. I must have been pretty bad at the other components, as I found myself working on the user interface, not my usual strength. The POC had a website frontend, and one thing I do know is HTML. After starting out in pure ASP.NET WebForms, I got frustrated as time was ticking, I knew what I wanted in HTML, but I couldnt coax the right output out of the ASP.NET controls. I needed two or three elements on the screen that were identical in layout, with different content. With a backup plan in  of writing the HTML into the response by hand, I decided to challenge myself a bit and see what I could do in an hour or two using the Microsoft submitted jQuery micro-templating JavaScript library. This risk paid off. I was able to quickly get the user interface up and running, responsive to the JSON data we were working with. I felt energized by the double win of getting the POC ready and learning something new. Opportunities  specifically like this POC dont come around often, but the takeaway is that while it wont be easy, there are ways to generate your own opportunities to grow towards greatness.Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Access Control Service: Transitioning between Active and Passive Scenarios

    - by Your DisplayName here!
    As I mentioned in my last post, ACS features a number of ways to transition between protocol and token types. One not so widely known transition is between passive sign ins (browser) and active service consumers. Let’s see how this works. We all know the usual WS-Federation handshake via passive redirect. But ACS also allows driving the sign in process yourself via specially crafted WS-Federation query strings. So you can use the following URL to sign in using LiveID via ACS. ACS will then redirect back to the registered reply URL in your application: GET /login.srf?   wa=wsignin1.0&   wtrealm=https%3a%2f%2faccesscontrol.windows.net%2f&   wreply=https%3a%2f%2fleastprivilege.accesscontrol.windows.net%3a443%2fv2%2fwsfederation&   wp=MBI_FED_SSL&   wctx=pr%3dwsfederation%26rm%3dhttps%253a%252f%252froadie%252facs2rp%252frest%252f The wsfederation bit in the wctx parameter indicates, that the response to the token request will be transmitted back to the relying party via a POST. So far so good – but how can an active client receive that token now? ACS knows an alternative way to send the token request response. Instead of doing the redirect back to the RP, it emits a page that in turn echoes the token response using JavaScript’s window.external.notify. The URL would look like this: GET /login.srf?   wa=wsignin1.0&   wtrealm=https%3a%2f%2faccesscontrol.windows.net%2f&   wreply=https%3a%2f%2fleastprivilege.accesscontrol.windows.net%3a443%2fv2%2fwsfederation&   wp=MBI_FED_SSL&   wctx=pr%3djavascriptnotify%26rm%3dhttps%253a%252f%252froadie%252facs2rp%252frest%252f ACS would then render a page that contains the following script block: <script type="text/javascript">     try{         window.external.Notify('token_response');     }     catch(err){         alert("Error ACS50021: windows.external.Notify is not registered.");     } </script> Whereas token_response is a JSON encoded string with the following format: {   "appliesTo":"...",   "context":null,   "created":123,   "expires":123,   "securityToken":"...",   "tokenType":"..." } OK – so how does this all come together now? As an active client (Silverlight, WPF, WP7, WinForms etc). application, you would host a browser control and use the above URL to trigger the right series of redirects. All the browser controls support one way or the other to register a callback whenever the window.external.notify function is called. This way you get the JSON string from ACS back into the hosting application – and voila you have the security token. When you selected the SWT token format in ACS – you can use that token e.g. for REST services. When you have selected SAML, you can use the token e.g. for SOAP services. In the next post I will show how to retrieve these URLs from ACS and a practical example using WPF.

    Read the article

  • Big Data – ClustrixDB – Extreme Scale SQL Database with Real-time Analytics, Releases Software Download – NewSQL

    - by Pinal Dave
    There are so many things to learn and there is so little time we all have. As we have little time we need to be selective to learn whatever we learn. I believe I know quite a lot of things in SQL but I still do not know what is around SQL. I have started to learn about NewSQL recently. If you wonder what is NewSQL I encourage all of you to read my blog post about NewSQL over here Big Data – Buzz Words: What is NewSQL – Day 10 of 21. NewSQL databases are quickly becoming popular – providing the scale of NoSQL with the SQL features and transactions. As a part of learning NewSQL database, I have recently started to learn about ClustrixDB. ClustrixDB has been the most mature NewSQL database used by some of the largest internet sites in the world for over 3 years, with extensive SQL support. In addition to scale, it provides fast real-time analytics by bringing massively parallel processing (MPP), available only in warehousing databases, to the transactional database. The reason I am more intrigued about learning ClustrixDB is their recent announcement on Oct 31. ClustrixDB was only available as an appliance, but now with their software release on Oct 31, everyone can use it. It is now available as forever free for up to 12 cores with community support, and there is a 45 day trial for unlimited cluster sizes. With the forever free world, I am indeed interested in ClustrixDB now. I know that few of the leading eCommerce sites in the world uses them for their transactional database. Here are few of the details I have quickly noted for ClustrixDB. ClustrixDB allows user to: Scale by simply adding nodes to the cluster with a single command Run billions of transactions a day Run fast real-time analytics Achieve high-availability with recovery from node failure Manages itself Easily migrate from MySQL as it is nearly plug-and-play compatible, use MySQL drivers, tools and replication. While I was going through the documentation I realized that ClustrixDB also has extensive support for SQL features including complex queries involving joins on a dozen or more tables, aggregates, sorts, sub-queries. It also supports stored procedures, triggers, foreign keys, partitioned and temporary tables, and fully online schema changes. It is indeed a very matured product and SQL solution. Indeed Clusterix sound very promising solution, I decided to dig a bit deeper to understand who are current customers of the Clustrix as they exist in the industry for quite a few years. Their client list is indeed very interesting and here is my quick research about them. Twoo.com – Europe’s largest social discovery (dating) site runs 4.4 Billion Transactions a day with table sizes over a Terabyte, on a 168 core cluster. EngageBDR – Top 3 in the online advertising category uses ClustrixDB to serve 6.9 billion ads a day through real-time bidding platform. Their reports went from 4 hours to 15 seconds. NoMoreRack – Top 2 fastest growing e-commerce company in US used ClustrixDB for high availability and fast growth through Amazon cloud. MakeMyTrip – India’s leading travel site runs on ClustrixDB with two clusters running as multi-master in Chennai and Bangalore. Many enterprises such as AOL, CSC, Rakuten, Symantec use ClustrixDB when their applications need scale. I must accept that I am impressed with the information I have learned so far and now is the time to do some hand’s on experience with their product. I want to learn this technology so in future when it is about NewSQL, I know what I am talking about. Read more why Clustrix explains why you ClustrixDB might be the right database for you. Download ClustrixDB with me today and install it on your machine so in future when we discuss the technical aspects of it, we all are on the same page. The software can be downloaded here. Reference : Pinal Dave (http://blog.SQLAuthority.com)Filed under: Big Data, MySQL, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL Tagged: Clustrix

    Read the article

  • Handling Configuration Changes in Windows Azure Applications

    - by Your DisplayName here!
    While finalizing StarterSTS 1.5, I had a closer look at lifetime and configuration management in Windows Azure. (this is no new information – just some bits and pieces compiled at one single place – plus a bit of reality check) When dealing with lifetime management (and especially configuration changes), there are two mechanisms in Windows Azure – a RoleEntryPoint derived class and a couple of events on the RoleEnvironment class. You can find good documentation about RoleEntryPoint here. The RoleEnvironment class features two events that deal with configuration changes – Changing and Changed. Whenever a configuration change gets pushed out by the fabric controller (either changes in the settings section or the instance count of a role) the Changing event gets fired. The event handler receives an instance of the RoleEnvironmentChangingEventArgs type. This contains a collection of type RoleEnvironmentChange. This in turn is a base class for two other classes that detail the two types of possible configuration changes I mentioned above: RoleEnvironmentConfigurationSettingsChange (configuration settings) and RoleEnvironmentTopologyChange (instance count). The two respective classes contain information about which configuration setting and which role has been changed. Furthermore the Changing event can trigger a role recycle (aka reboot) by setting EventArgs.Cancel to true. So your typical job in the Changing event handler is to figure if your application can handle these configuration changes at runtime, or if you rather want a clean restart. Prior to the SDK 1.3 VS Templates – the following code was generated to reboot if any configuration settings have changed: private void RoleEnvironmentChanging(object sender, RoleEnvironmentChangingEventArgs e) {     // If a configuration setting is changing     if (e.Changes.Any(change => change is RoleEnvironmentConfigurationSettingChange))     {         // Set e.Cancel to true to restart this role instance         e.Cancel = true;     } } This is a little drastic as a default since most applications will work just fine with changed configuration – maybe that’s the reason this code has gone away in the 1.3 SDK templates (more). The Changed event gets fired after the configuration changes have been applied. Again the changes will get passed in just like in the Changing event. But from this point on RoleEnvironment.GetConfigurationSettingValue() will return the new values. You can still decide to recycle if some change was so drastic that you need a restart. You can use RoleEnvironment.RequestRecycle() for that (more). As a rule of thumb: When you always use GetConfigurationSettingValue to read from configuration (and there is no bigger state involved) – you typically don’t need to recycle. In the case of StarterSTS, I had to abstract away the physical configuration system and read the actual configuration (either from web.config or the Azure service configuration) at startup. I then cache the configuration settings in memory. This means I indeed need to take action when configuration changes – so in my case I simply clear the cache, and the new config values get read on the next access to my internal configuration object. No downtime – nice! Gotcha A very natural place to hook up the RoleEnvironment lifetime events is the RoleEntryPoint derived class. But with the move to the full IIS model in 1.3 – the RoleEntryPoint methods get executed in a different AppDomain (even in a different process) – see here.. You might no be able to call into your application code to e.g. clear a cache. Keep that in mind! In this case you need to handle these events from e.g. global.asax.

    Read the article

  • Detect Unicode Usage in SQL Column

    One optimization you can make to a SQL table that is overly large is to change from nvarchar (or nchar) to varchar (or char).  Doing so will cut the size used by the data in half, from 2 bytes per character (+ 2 bytes of overhead for varchar) to only 1 byte per character.  However, you will lose the ability to store Unicode characters, such as those used by many non-English alphabets.  If the tables are storing user-input, and your application is or might one day be used internationally, its likely that using Unicode for your characters is a good thing.  However, if instead the data is being generated by your application itself or your development team (such as lookup data), and you can be certain that Unicode character sets are not required, then switching such columns to varchar/char can be an easy improvement to make. Avoid Premature Optimization If you are working with a lookup table that has a small number of rows, and is only ever referenced in the application by its numeric ID column, then you wont see any benefit to using varchar vs. nvarchar.  More generally, for small tables, you wont see any significant benefit.  Thus, if you have a general policy in place to use nvarchar/nchar because it offers more flexibility, do not take this post as a recommendation to go against this policy anywhere you can.  You really only want to act on measurable evidence that suggests that using Unicode is resulting in a problem, and that you wont lose anything by switching to varchar/char. Obviously the main reason to make this change is to reduce the amount of space required by each row.  This in turn affects how many rows SQL Server can page through at a time, and can also impact index size and how much disk I/O is required to respond to queries, etc.  If for example you have a table with 100 million records in it and this table has a column of type nchar(5), this column will use 5 * 2 = 10 bytes per row, and with 100M rows that works out to 10 bytes * 100 million = 1000 MBytes or 1GB.  If it turns out that this column only ever stores ASCII characters, then changing it to char(5) would reduce this to 5*1 = 5 bytes per row, and only 500MB.  Of course, if it turns out that it only ever stores the values true and false then you could go further and replace it with a bit data type which uses only 1 byte per row (100MB  total). Detecting Whether Unicode Is In Use So by now you think that you have a problem and that it might be alleviated by switching some columns from nvarchar/nchar to varchar/char but youre not sure whether youre currently using Unicode in these columns.  By definition, you should only be thinking about this for a column that has a lot of rows in it, since the benefits just arent there for a small table, so you cant just eyeball it and look for any non-ASCII characters.  Instead, you need a query.  Its actually very simple: SELECT DISTINCT(CategoryName)FROM CategoriesWHERE CategoryName <> CONVERT(varchar, CategoryName) Summary Gregg Stark for the tip. Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • SQL SERVER – Curious Case of Disappearing Rows – ON UPDATE CASCADE and ON DELETE CASCADE – T-SQL Example – Part 2 of 2

    - by pinaldave
    Yesterday I wrote a real world story of how a friend who thought they have an issue with intrusion or virus whereas the issue was really in the code. I strongly suggest you read my earlier blog post Curious Case of Disappearing Rows – ON UPDATE CASCADE and ON DELETE CASCADE – Part 1 of 2 before continuing this blog post as this is second part of the first blog post. Let me reproduce the simple scenario in T-SQL. Building Sample Data USE [TestDB] GO -- Creating Table Products CREATE TABLE [dbo].[Products]( [ProductID] [int] NOT NULL, [ProductDesc] [varchar](50) NOT NULL, CONSTRAINT [PK_Products] PRIMARY KEY CLUSTERED ( [ProductID] ASC )) ON [PRIMARY] GO -- Creating Table ProductDetails CREATE TABLE [dbo].[ProductDetails]( [ProductDetailID] [int] NOT NULL, [ProductID] [int] NOT NULL, [Total] [int] NOT NULL, CONSTRAINT [PK_ProductDetails] PRIMARY KEY CLUSTERED ( [ProductDetailID] ASC )) ON [PRIMARY] GO ALTER TABLE [dbo].[ProductDetails] WITH CHECK ADD CONSTRAINT [FK_ProductDetails_Products] FOREIGN KEY([ProductID]) REFERENCES [dbo].[Products] ([ProductID]) ON UPDATE CASCADE ON DELETE CASCADE GO -- Insert Data into Table USE TestDB GO INSERT INTO Products (ProductID, ProductDesc) SELECT 1, 'Bike' UNION ALL SELECT 2, 'Car' UNION ALL SELECT 3, 'Books' GO INSERT INTO ProductDetails ([ProductDetailID],[ProductID],[Total]) SELECT 1, 1, 200 UNION ALL SELECT 2, 1, 100 UNION ALL SELECT 3, 1, 111 UNION ALL SELECT 4, 2, 200 UNION ALL SELECT 5, 3, 100 UNION ALL SELECT 6, 3, 100 UNION ALL SELECT 7, 3, 200 GO Select Data from Tables -- Selecting Data SELECT * FROM Products SELECT * FROM ProductDetails GO Delete Data from Products Table -- Deleting Data DELETE FROM Products WHERE ProductID = 1 GO Select Data from Tables Again -- Selecting Data SELECT * FROM Products SELECT * FROM ProductDetails GO Clean up Data -- Clean up DROP TABLE ProductDetails DROP TABLE Products GO My friend was confused as there was no delete was firing over ProductsDetails Table still there was a delete happening. The reason was because there is a foreign key created between Products and ProductsDetails Table with the keywords ON DELETE CASCADE. Due to ON DELETE CASCADE whenever is specified when the data from Table A is deleted and if it is referenced in another table using foreign key it will be deleted as well. Workaround 1: Design Changes – 3 Tables Change the design to have more than two tables. Create One Product Mater Table with all the products. It should historically store all the products list in it. No products should be ever removed from it. Add another table called Current Product and it should contain only the table which should be visible in the product catalogue. Another table should be called as ProductHistory table. There should be no use of CASCADE keyword among them. Workaround 2: Design Changes - Column IsVisible You can keep the same two tables. 1) Products and 2) ProductsDetails. Add a column with BIT datatype to it and name it as a IsVisible. Now change your application code to display the catalogue based on this column. There should be no need to delete anything. Workaround 3: Bad Advices (Bad advises begins here) The reason I have said bad advices because these are going to be bad advices for sure. You should make necessary design changes and not use poor workarounds which can damage the system and database integrity further. Here are the examples 1) Do not delete the data – well, this is not a real solution but can give time to implement design changes. 2) Do not have ON CASCADE DELETE – in this case, you will have entry in productsdetails which will have no corresponding product id and later on there will be lots of confusion. 3) Duplicate Data – you can have all the data of the product table move to the product details table and repeat them at each row. Now remove CASCADE code. This will let you delete the product table rows without any issue. There are so many things wrong this suggestion, that I will not even start here. (Bad advises ends here)  Well, did I miss anything? Please help me with your suggestions. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Give a session on C++ AMP – here is how

    - by Daniel Moth
    Ever since presenting on C++ AMP at the AMD Fusion conference in June, then the Gamefest conference in August, and the BUILD conference in September, I've had numerous requests about my material from folks that want to re-deliver the same session. The C++ AMP session I put together has evolved over the 3 presentations to its final form that I used at BUILD, so that is the one I recommend you base yours on. Please get the slides and the recording from channel9 (I'll refer to slide numbers below). This is how I've been presenting the C++ AMP session: Context (slide 3, 04:18-08:18) Start with a demo, on my dual-GPU machine. I've been using the N-Body sample (for VS 11 Developer Preview). (slide 4) Use an nvidia slide that has additional examples of performance improvements that customers enjoy with heterogeneous computing. (slide 5) Talk a bit about the differences today between CPU and GPU hardware, leading to the fact that these will continue to co-exist and that GPUs are great for data parallel algorithms, but not much else today. One is a jack of all trades and the other is a number cruncher. (slide 6) Use the APU example from amd, as one indication that the hardware space is still in motion, emphasizing that the C++ AMP solution is a data parallel API, not a GPU API. It has a future proof design for hardware we have yet to see. (slide 7) Provide more meta-data, as blogged about when I first introduced C++ AMP. Code (slide 9-11) Introduce C++ AMP coding with a simplistic array-addition algorithm – the slides speak for themselves. (slide 12-13) index<N>, extent<N>, and grid<N>. (Slide 14-16) array<T,N>, array_view<T,N> and comparison between them. (Slide 17) parallel_for_each. (slide 18, 21) restrict. (slide 19-20) actual restrictions of restrict(direct3d) – the slides speak for themselves. (slide 22) bring it altogether with a matrix multiplication example. (slide 23-24) accelerator, and accelerator_view. (slide 26-29) Introduce tiling incl. tiled matrix multiplication [tiling probably deserves a whole session instead of 6 minutes!]. IDE (slide 34,37) Briefly touch on the concurrency visualizer. It supports GPU profiling, but enhancements specific to C++ AMP we hope will come at the Beta timeframe, which is when I'll be spending more time talking about it. (slide 35-36, 51:54-59:16) Demonstrate the GPU debugging experience in VS 11. Summary (slide 39) Re-iterate some of the points of slide 7, and add the point that the C++ AMP spec will be open for other compiler vendors to implement, even on other platforms (in fact, Microsoft is actively working on that). (slide 40) Links to content – see slide – including where all your questions should go: http://social.msdn.microsoft.com/Forums/en/parallelcppnative/threads.   "But I don't have time for a full blown session, I only need 2 (or just 1, or 3) C++ AMP slides to use in my session on related topic X" If all you want is a small number of slides, you can take some from the session above and customize them. But because I am so nice, I have created some slides for you, including talking points in the notes section. Download them here. Comments about this post by Daniel Moth welcome at the original blog.

    Read the article

  • Fresh Ubuntu Install - Grub not loading

    - by Ryan Sharp
    System Ubuntu 12.04 64-bit Windows 7 SP1 Samsung 64GB SSD - OS' Samsung 1TB HDD - Games, /Home, Swap WD 300'ishGB HDD - Backup Okay, so I'm very frustrated, so please excuse me if I miss anything out as my head is clouded by anger and impatience, etc. I'll try me best, though. First of all, I'll explain how I got to my predicament. I finally got my new SSD. I firstly installed Windows, which completed without a hitch. Afterwards, I tried to install Ubuntu, which failed several times due to problems irrelevant to this question, but I mention this to explain my frustrations, sorry. Anyway, I finally installed Ubuntu. However, I chose the 'bootloader' to be installed on the same partition as where I was installing the Ubuntu Root partition, as that was what I believed to be the best choice. It was of my thinking that it was supposed to go on the same partition and on the SSD, which is my OS drive, though with my problem, it apparently was wrong. So I tried to fix it by checking guides and following their directions, but seemed to have messed it up even more. Here is what I receive after I use the fdisk -l command: (I also added explanations for which I used each partition for) Disk /dev/sda: 64.0 GB, 64023257088 bytes 255 heads, 63 sectors/track, 7783 cylinders, total 125045424 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x324971d1 Device Boot Start End Blocks Id System /dev/sda1 * 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 208896 48957439 24374272 7 HPFS/NTFS/exFAT /dev/sda3 48959486 125044735 38042625 5 Extended /dev/sda5 48959488 125044735 38042624 83 Linux sda1 --/ Windows Recovery sda2 --/ Windows 7 sda3/5 --/ Ubuntu root [ / ] Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xc0ee6a69 Device Boot Start End Blocks Id System /dev/sdb1 1024208894 1953523711 464657409 5 Extended /dev/sdb3 * 2048 1024206847 512102400 7 HPFS/NTFS/exFAT /dev/sdb5 1024208896 1939851263 457821184 83 Linux /dev/sdb6 1939853312 1953523711 6835200 82 Linux swap / Solaris sdb3 --/ Partition for Steam games, etc. sdb5 --/ Ubuntu Home [ /home ] sdb6 --/ Ubuntu Swap Partition table entries are not in disk order Disk /dev/sdc: 320.1 GB, 320072933376 bytes 255 heads, 63 sectors/track, 38913 cylinders, total 625142448 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x292eee23 Device Boot Start End Blocks Id System /dev/sdc1 2048 625141759 312569856 7 HPFS/NTFS/exFAT sdc1 --/ Generic backup I also used a Boot Script that other users suggested, so that I can give more details on my partitions and also where Grub is located... ============================= Boot Info Summary: =============================== => Grub2 (v1.99) is installed in the MBR of /dev/sda and looks at sector 1 of the same hard drive for core.img. core.img is at this location and looks for (,msdos5)/boot/grub on this drive. => Grub2 (v1.99) is installed in the MBR of /dev/sdb and looks at sector 1 of the same hard drive for core.img. core.img is at this location and looks for (,msdos5)/boot/grub on this drive. => Windows is installed in the MBR of /dev/sdc. Now that is weird... Why would Grub2 be installed on both my SSD and HDD? Even weirder is why is Windows on the MBR of my backup hard drive? Nothing I did should have done that... Anyway, here is the entire Output from that script... PASTEBIN So, to summarize what I need: How can I fix my setup so grub loads on startup? How can I clean my partitions to remove unnecessary grubs? What did I do wrong so that I don't do something so daft again? Thank you so much for reading, and I hope you can help me. I've been trying to have a successful setup since Friday, and I'm almost at the point that I'm really tempted to throw my computer out the window due to my frustration.

    Read the article

  • Cannot Mount USB 3.0 Hard Disk ?!!

    - by Tenken
    Hi, I have a USB 3.0 external hard disk which I am unable to mount. The entry appears in the "lsusb" command, but I do not exactly understand how to mount it. This is the output for my lsusb command. "ASMedia Technology Inc." is the USB 3.0 device. I would appreciate some help in mounting and accessing the hard disk. This the relevant output of my "lsusb -v" : Bus 009 Device 002: ID 174c:5106 ASMedia Technology Inc. Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x174c ASMedia Technology Inc. idProduct 0x5106 bcdDevice 0.01 iManufacturer 2 ASMedia iProduct 3 AS2105 iSerial 1 00000000000000000000 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 009 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 3 bMaxPacketSize0 9 idVendor 0x1d6b Linux Foundation idProduct 0x0003 3.0 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.35-28-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:04:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0503 highspeed power enable connect Port 4: 0000.0503 highspeed power enable connect Device Status: 0x0003 Self Powered Remote Wakeup Enabled This is the error given when I try to mount the hard drive: shinso@shinso-IdeaPad:~$ sudo mount /dev/sdb /mnt [sudo] password for shinso: mount: /dev/sdb: unknown device This the output of "dmesg|tail": [30062.774178] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [30535.800977] usb 9-4: USB disconnect, address 3 [30659.237342] Valid eCryptfs headers not found in file header region or xattr region [30659.237351] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31259.268310] Valid eCryptfs headers not found in file header region or xattr region [31259.268313] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31860.059058] Valid eCryptfs headers not found in file header region or xattr region [31860.059062] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [32465.220590] Valid eCryptfs headers not found in file header region or xattr region [32465.220593] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO I am using Ubuntu 10.10 (64 bit). Any help is appreciated.

    Read the article

  • Roles / Profiles / Perspectives in NetBeans IDE 7.1

    - by Geertjan
    With a check out of main-silver from yesterday, I'm able to use the brand new "role" attribute in @TopComponent.Registration, as you can see below, in the bit in bold: @ConvertAsProperties(dtd = "-//org.role.demo.ui//Admin//EN", autostore = false) @TopComponent.Description(preferredID = "AdminTopComponent", //iconBase="SET/PATH/TO/ICON/HERE", persistenceType = TopComponent.PERSISTENCE_ALWAYS) @TopComponent.Registration(mode = "editor", openAtStartup = true, role="admin") public final class AdminTopComponent extends TopComponent { And here's a window for general users of the application, with the "role" attribute set to "user": @ConvertAsProperties(dtd = "-//org.role.demo.ui//User//EN", autostore = false) @TopComponent.Description(preferredID = "UserTopComponent", //iconBase="SET/PATH/TO/ICON/HERE", persistenceType = TopComponent.PERSISTENCE_ALWAYS) @TopComponent.Registration(mode = "explorer", openAtStartup = true, role="user") public final class UserTopComponent extends TopComponent { So, I have two windows. One is assigned to the "admin" role, the other to the "user" role. In the "ModuleInstall" class, I add a "WindowSystemListener" and set "user" as the application's role: public class Installer extends ModuleInstall implements WindowSystemListener { @Override public void restored() { WindowManager.getDefault().addWindowSystemListener(this); } @Override public void beforeLoad(WindowSystemEvent event) { WindowManager.getDefault().setRole("user"); WindowManager.getDefault().removeWindowSystemListener(this); } @Override public void afterLoad(WindowSystemEvent event) { } @Override public void beforeSave(WindowSystemEvent event) { } @Override public void afterSave(WindowSystemEvent event) { } } So, when the application starts, the "UserTopComponent" is shown, not the "AdminTopComponent". Next, I have two Actions, for switching between the two roles, as shown below: @ActionID(category = "Window", id = "org.role.demo.ui.SwitchToAdminAction") @ActionRegistration(displayName = "#CTL_SwitchToAdminAction") @ActionReferences({ @ActionReference(path = "Menu/Window", position = 250) }) @Messages("CTL_SwitchToAdminAction=Switch To Admin") public final class SwitchToAdminAction extends AbstractAction { @Override public void actionPerformed(ActionEvent e) { WindowManager.getDefault().setRole("admin"); } @Override public boolean isEnabled() { return !WindowManager.getDefault().getRole().equals("admin"); } } @ActionID(category = "Window", id = "org.role.demo.ui.SwitchToUserAction") @ActionRegistration(displayName = "#CTL_SwitchToUserAction") @ActionReferences({ @ActionReference(path = "Menu/Window", position = 250) }) @Messages("CTL_SwitchToUserAction=Switch To User") public final class SwitchToUserAction extends AbstractAction { @Override public void actionPerformed(ActionEvent e) { WindowManager.getDefault().setRole("user"); } @Override public boolean isEnabled() { return !WindowManager.getDefault().getRole().equals("user"); } } When I select one of the above actions, the role changes, and the other window is shown. I could, of course, add a Login dialog to the "SwitchToAdminAction", so that authentication is required in order to switch to the "admin" role. Now, let's say I am now in the "user" role. So, the "UserTopComponent" shown above is now opened. I decide to also open another window, the Properties window, as below... ...and, when I am in the "admin" role, when the "AdminTopComponent" is open, I decide to also open the Output window, as below... Now, when I switch from one role to the other, the additional window/s I opened will also be opened, together with the explicit members of the currently selected role. And, the main window position and size are also persisted across roles. When I look in the "build" folder of my project in development, I see two different Windows2Local folders, one per role, automatically created by the fact that there is something to be persisted for a particular role, e.g., when a switch to a different role is done: And, with that, we now clearly have roles/profiles/perspectives in NetBeans Platform applications from NetBeans Platform 7.1 onwards.

    Read the article

  • Unable to Sign in to the Microsoft Online Services Signin application from Windows 7 client located behind ISA firewall

    - by Ravindra Pamidi
    A while ago i helped a customer troubleshoot authentication problem with Microsoft Online Services Signin application.  This customer was evaluating Microsoft BPOS (Business Productivity Online Services) and was having trouble using the single sign on application behind ISA 2004 firewall.The network structure is fairly simple with single Windows 2003 Active Directory domain and Windows 7 clients. On a successful logon to the Microsoft Online Services Signin application, this application provides single signon functionality to all of Microsoft online services in the BPOS package. Symptoms:When trying to signin it fails with error "The service is currently unavailable. Please try again later. If problems continue, contact your service administrator". If ISA 2004 firewall is removed from the picture the authentication succeeds.Troubleshooting: Enabled ISA Server firewall logging along with Microsoft Network Monitor tool on the Windows 7 Client while reproducing the issue. Analysis of the ISA Server Firewall logs and Microsoft Network capture revealed that the Microsoft Online Services Sign In application when sending request to ISA Server does not send the domain credentials and as a result ISA Server responds with an error code of HTTP 407 Proxy authentication required listing out the supported authentication mechanisms.  The application in question is expected to send the credentials of the domain user in response to this request. However in this case, it fails to send the logged on user's domain credentials. Bit of researching on the Internet revealed that The "Microsoft Online Services Sign In" application by default does not support Outbound Internet Proxy authentication. In order for it to send the logged on user's domain credentials we had to make  changes to its configuration file "SignIn.exe.config" located under "Program Files\Microsoft Online Services\Sign In" folder. Step by Step details to configure the configuration file are documented on Microsoft TechNet website given below.  Configure your outbound authenticating proxy serverhttp://www.microsoft.com/online/help/en-us/helphowto/cc54100d-d149-45a9-8e96-f248ecb1b596.htm After the above problem was addressed we were still not able to use the "Microsoft Online Services Sign In" application and it failed with the same error.  Analysis of another network capture revealed that the application in question is now sending the required credentials and the connection seems to terminate at a later stage. Enabled verbose logging for the "Microsoft Online Services Sign In" application and then reproduced the problem. Analysis of the logs revealed a time difference between the local client and Microsoft Online services server of around seven minutes which is above the acceptable time skew of five minutes. Excerpt from Microsoft Online Services Sign In application verbose log:  1/26/2012 1:57:51 PM Verbose SingleSignOn.GetSSOGenericInterface SSO Interface URL: https://signinservice.apac.microsoftonline.com/ssoservice/UID1/26/2012 1:57:52 PM Exception SSOSignIn.SignIn The security timestamp is invalid because its creation time ('2012-01-26T08:34:52.767Z') is in the future. Current time is '2012-01-26T08:27:52.987Z' and allowed clock skew is '00:05:00'.1/26/2012 1:57:52 PM Exception SSOSignIn.SignIn  Although the Windows 7 Clients successfully synchronized time to the domain controller for the domain, the domain controller was not configured to synchronize time with external NTP servers. This caused a gradual drift in time on the network thus resulting in the above issue. Reconfigured the domain controller holding the PDC FSMO role to synchronize time with external time source ( time.nist.gov ) and edited the system policy on the ISA server firewall to allow NTP traffic to time.nist.gov Configure the time source for the forest:Windows Time Servicehttp://technet.microsoft.com/en-us/library/cc794937(WS.10).aspx Forced synchronization of Windows time using the command w32tm /resync on the domain controller and later on the clients each of which had corrected the seven minutes difference. This resolved the problem with logon to Microsoft Online Services Sign In.

    Read the article

  • 12.04 making BCM4313 card work with aircrack-ng?

    - by Charles Forest
    I'm a real Linux Noob, just started using it (this month) and until now i had no issues. now i'm trying to set-up aircrack-ng on my laptop, but it seems like it's using the worst card possible (or almost) there is a TON of tutorial on this card (seems to be hell to set-up) i have tryed some, but i ended up uninstalling my drivers, messing with my desktops, and ended by having no more "X" to close my windows (i have no clue how i ended there) i just re-installed my linux (took me 2 hours to setup everything again), but now i'm a bit "Scared" to try tutorials randomly again. Right now it says the driver is wl, wich is not the one i want (AFAIK it's not supported) i'm not sure what kind of informations are needed, but here's what i think could be usefull. lspci -knn 00:00.0 Host bridge [0600]: Intel Corporation 2nd Generation Core Processor Family DRAM Controller [8086:0104] (rev 09) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: agpgart-intel 00:01.0 PCI bridge [0604]: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port [8086:0101] (rev 09) Kernel driver in use: pcieport Kernel modules: shpchp 00:02.0 VGA compatible controller [0300]: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller [8086:0116] (rev 09) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: i915 Kernel modules: i915 00:16.0 Communication controller [0780]: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 [8086:1c3a] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: mei Kernel modules: mei 00:1a.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 [8086:1c2d] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: ehci_hcd 00:1b.0 Audio device [0403]: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller [8086:1c20] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: snd_hda_intel Kernel modules: snd-hda-intel 00:1c.0 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 [8086:1c10] (rev b4) Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.3 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 [8086:1c16] (rev b4) Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.4 PCI bridge [0604]: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 [8086:1c18] (rev b4) Kernel driver in use: pcieport Kernel modules: shpchp 00:1d.0 USB controller [0c03]: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 [8086:1c26] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: ehci_hcd 00:1f.0 ISA bridge [0601]: Intel Corporation HM65 Express Chipset Family LPC Controller [8086:1c49] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel modules: iTCO_wdt 00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: ahci 00:1f.3 SMBus [0c05]: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller [8086:1c22] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel modules: i2c-i801 01:00.0 3D controller [0302]: NVIDIA Corporation GF108 [GeForce GT 540M] [10de:0df4] (rev a1) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: nouveau Kernel modules: nouveau, nvidiafb WIRELESS CARD 02:00.0 Network controller [0280]: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller [14e4:4727] (rev 01) Subsystem: Wistron NeWeb Corp. Device [185f:051a] Kernel driver in use: wl Kernel modules: wl, bcma, brcmsmac REST... 03:00.0 Ethernet controller [0200]: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller [10ec:8168] (rev 06) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: r8169 Kernel modules: r8169 04:00.0 USB controller [0c03]: NEC Corporation uPD720200 USB 3.0 Host Controller [1033:0194] (rev 04) Subsystem: Samsung Electronics Co Ltd Device [144d:c0a5] Kernel driver in use: xhci_hcd Also, if i'm "screwed" with my hardware, just tell me.

    Read the article

  • Syntax of passing lambda

    - by Astara
    Right now, I'm working on refactoring a program that calls its parts by polling to a more event-driven structure. I've created sched and task classes with the sced to become a base class of the current main loop. The tasks will be created for each meter so they can be called off of that instead of polling. Each of the events main calls are a type of meter that gather info and display it. When the program is coming up, all enabled meters get 'constructed' by a main-sub. In that sub, I want to store off the "this" pointer associated with the meter, as well as the common name for the "action routine. void MeterMaker::Meter_n_Task (Meter * newmeter,) { push(newmeter); // handle non-timed draw events Task t = new Task(now() + 0.5L); t.period={0,1U}; t.work_meter = newmeter; t.work = [&newmeter](){newmeter.checkevent();};<<--attempt at lambda t.flags = T_Repeat; t.enable_task(); _xos->sched_insert(t); } A sample call to it: Meter_n_Task(new CPUMeter(_xos, "CPU ")); 've made the scheduler a base class of the main routine (that handles the loop), and I've tried serveral variations to get the task class to be a base of the meter class, but keep running into roadblocks. It's alot like "whack-a-mole" -- pound in something to fix something one place, and then a new probl pops out elsewhere. Part of the problem, is that the sched.h file that is trying to hold the Task Q, includes the Task header file. The task file Wants to refer to the most "base", Meter class. The meter class pulls in the main class of the parent as it passes a copy of the parent to the children so they can access the draw routines in the parent. Two references in the task file are for the 'this' pointer of the meter and the meter's update sub (to be called via this). void *this_data= NULL; void (*this_func)() = NULL; Note -- I didn't really want to store these in the class, as I wanted to use a lamdba in that meter&task routine above to store a routine+context to be used to call the meter's action routine. Couldn't figure out the syntax. But am running into other syntax problems trying to store the pointers...such as g++: COMPILE lsched.cc In file included from meter.h:13:0, from ltask.h:17, from lsched.h:13, from lsched.cc:13: xosview.h:30:47: error: expected class-name before ‘{’ token class XOSView : public XWin, public Scheduler { Like above where it asks for a class, where the classname "Scheduler" is. !?!? Huh? That IS a class name. I keep going in circles with things that don't make sense... Ideally I'd get the lamba to work right in the Meter_n_Task routine at the top. I wanted to only store 1 pointer in the 'Task' class that was a pointer to my lambda that would have already captured the "this" value ... but couldn't get that syntax to work at all when I tried to start it into a var in the 'Task' class. This project, FWIW, is my teething project on the new C++... (of course it's simple!.. ;-))... I've made quite a bit of progress in other areas in the code, but this lambda syntax has me stumped...its at times like thse that I appreciate the ease of this type of operation in perl. Sigh. Not sure the best way to ask for help here, as this isn't a simple question. But thought I'd try!... ;-) Too bad I can't attach files to this Q.

    Read the article

  • Part 6: Extensions vs. Modifications

    - by volker.eckardt(at)oracle.com
    Customizations = Extensions + Modifications In the EBS terminology, a customization can be an extension or a modification. Extension means that you mainly create your own code from scratch. You may utilize existing views, packages and java classes, but your code is unique. Modifications are quite different, because here you take existing code and change or enhance certain areas to achieve a slightly different behavior. Important is that it doesn't matter if you place your code at the same or at another place – it is a modification. It is also not relevant if you leave the original code enabled or not! Why? Here is the answer: In case the original code piece you have taken as your base will get patched, you need to copy the source again and apply all your changes once more. If you don't do that, you may get different results or write different data compared to the standard – this causes a high risk! Here are some guidelines how to reduce the risk: Invest a bit longer when searching for objects to select data from. Rather choose a view than a table. In case Oracle development changes the underlying tables, the view will be more stable and is therefore a better choice. Choose rather public APIs over internal APIs. Same background as before: although internal structure might change, the public API is more stable. Use personalization and substitution rather than modification. Spend more time to check if the requirement can be covered with such techniques. Build a project code library, avoid that colleagues creating similar functionality multiple times. Otherwise you have to review lots of similar code to determine the need for correction. Use the technique of “flagged files”. Flagged files is a way to mark a standard deployment file. If you run the patch analyse (within Application Manager), the analyse result will list flagged standard files in case they will be patched. If you maintain a cross reference to your own CEMLIs, you can easily determine which CEMLIs have to be reviewed. Implement a code review process. This can be done by utilizing team internal or external persons. If you implement such a team internal process, your team members will come up with suggestions how to improve the code quality by themselves. Review heavy customizations regularly, to identify options to reduce complexity; let's say perform this every 6th month. You may not spend days for such a review, but a high level cross check if the customization can be reduced is suggested. De-install customizations which are no more required. Define a process for this. Add a section into the technical documentation how to uninstall and what are possible implications. Maintain a cross reference between CEMLIs and between CEMLIs, EBS modules and business processes. Keep this list up to date! Share this list! By following these guidelines, you are able to improve product stability. Although we might not be able to avoid modifications completely, we can give a much better advise to developers and to our test team. Summary: Extensions and Modifications have to be handled differently during their lifecycle. Modifications implicate a much higher risk and should therefore be reviewed more frequently. Good cross references allow you to give clear advise for the testing activities.

    Read the article

  • Take Snapshots of Your Favorite Movie Scenes in VLC

    - by DigitalGeekery
    Have you ever wanted to grab a screenshot of your favorite TV or movie scene? Today we’ll show you how to do so with VLC Media Player. If you don’t have it already, download and install the latest version of VLC (link below). Start playing your movie, and to grab a snapshot, select Video from the menu and click Snapshot.   When you take a snapshot, by default a preview is displayed at the top left and the folder where the file is saved is briefly displayed on the screen. If you enable the Advanced Controls, you can take a snapshot with a click of a button, and advance the video frame by frame to get a more accurate shot. To enable the Advanced Controls, select View and Advanced Controls.   You’ll see the Advanced Controls buttons appear below the slider. Now just click on the Snapshot button to grab an image.   You can more easily control the frame you wish to grab by pressing the Frame by Frame button. You can pause the movie when it is near the perfect spot for your snapshot, and then press the Frame by Frame button to advance a single frame at a time. By default, the snapshots are saved as PNG files in your My Pictures folder in Windows. You can change those setting in the Preferences. First, you’ll need to select All under Show settings at the bottom. Then click on Video on the left. Scroll down a bit and you’ll see the Snapshot section. Here you can change the format from PNG to JPG, change the directory to which the snapshots are stored, turn on and off the preview, and change the filename prefix. Click Save when finished.   Now you have nice screenshots of your favorite movie to display as you wish…such as a Desktop Background!   VLC is an excellent media player that runs on Windows, Mac, and Linux. In addition to playing almost any media file, it also makes grabbing screenshots of your videos a breeze. Want to know more about VLC? Check out some of our previous articles like how to rip DVDs and how to set a video as your desktop wallpaper. Download the Latest version of VLC Similar Articles Productive Geek Tips Desktop Fun: Rural Scenes WallpapersAutomatically Mount and View ISO files in Windows 7 Media CenterHow to Make/Edit a movie with Windows Movie Maker in Windows VistaAdd Images and Metadata to Windows 7 Media Center Movie LibraryQuickly Find Movies to Watch at Hello Movies TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Xobni Plus for Outlook All My Movies 5.9 CloudBerry Online Backup 1.5 for Windows Home Server Snagit 10 tinysong gives a shortened URL for you to post on Twitter (or anywhere) 10 Superb Firefox Wallpapers OpenDNS Guide Google TV The iPod Revolution Ultimate Boot CD can help when disaster strikes

    Read the article

  • Where Have All the Ugly Forms Gone? Users and ADF Took Care Of It

    - by ultan o'broin
    Sometimes I hear that our application demos are a bit too "cutsey" and that we never talk about with any user roles that have lots of data entry as a requirement. Some (no names) consider those old clunker forms, with the myriad rows of fields, to be super-productive for data clerks. We do have such roles covered in Oracle Fusion Applications for sure. But consider what is really the issue here: productivity. Check out how the Oracle Fusion Financials Applications User Experience team went about designing for productivity when receiving and entering invoice data, for example. See how Fusion Financials caters so well for input and control of data? Central to all this is knowing the users and how they work: what tasks do they need to perform, and when. Read more about Fusion Financials productivity in the white paper, Get It Done Fast, Get It Done Right: The Oracle Fusion Financials User Experience. Now and then, I see forms that weren't designed for end user activity at all. Instead, they were designed by developers or by the IT department around the database schema. Forms with literally dozens of fields on the same page, sometimes. Forms that give the impression there was only task involved, when there may have been several. At times, completing one of these huge forms accurately became so tedious that, under pressure, it made more sense for the user to complete it quickly as possible and then let somebody else check it for accuracy and fill in the gaps from data emailed along in spreadsheet form. Data accuracy is critical in our business. Not good. Not efficient. Not productive. So here are a few basics on forms design for data entry-type user roles. A great place for developers to start exploring what is possible with forms layout is the Rich Client User Experience (RCUX) guidance on Form Layout, using ADF components. User-Centered Forms Design Considerations The starting point--something you must always keep in mind with your own design--is design for the end user. Find a representative end user, and keep that user engaged throughout the design, deployment, and test process. Consider these points in user testing those forms: Are there automated or technical solutions to entering the data that avoid manual input in the first place? For example, imports, uploads, OCR, whatever. Some day we will be able to tell Siri to do it, but leave that for now. Design your form to reflect the task involved (i.e., the business process) and not the database schema. On the form, group like fields together, logically. Eliminate duplicate data entry or prepopulate from previous data entry. Allow users to complete fields in the order they wish (i.e., no interdependency). Allow for tabbing between fields (keyboard is faster than mouse), so know how the browser supports this (see that RCUX guideline). Allow for final validation at the page level not at field-level entry. Way better for heads-down users. For example, ADF messages allow you to see a list of all validation errors on a page on a final submit or navigation action and to easily navigate to the point of error. Better still, be error tolerant. Allow users to enter data in formats they comfortable with. Bind any relevant user preference setting to the input format allowed (for example, the locale date format). Explore what data entry conversion can do for you automatically too (see the ADF converter demos, convenience patterns can also be written). Only ask for data input when it's needed. Get rid of, or hide optional fields. Cut down on the number of mandatory fields, and mark them clearly (use a *). Clearly label the fields in plain language. I am sure you may have a few more tips on forms design for data entry users. Remember the user before finding the comments.

    Read the article

  • Passed: Exam 70-480: Programming in HTML5 with JavaScript and CSS3

    First off: Mission accomplished successfully. And it was fun! Using the resources listed in my previous article about Learning Content, I'd like to thank Microsoft Technical Evangelists Jeremy Foster and Michael Palermo for their excellent jump start videos on Channel 9, and the various authors at Pluralsight. Local Prometric testing centre Back in November I chose a local testing centre which was the easiest to access from my office despite the horrible traffic you might experience here on the island. Actually, it was not the closest one. But due to their website, their awards as Microsoft Learning Center, and my general curiosity about the premises, I gave FRCI my priority. Boy, how should I regret this decision this morning... The official Prometric exam guide asks any attendee to show up at least 30 minutes prior to the scheduled time of the test. Well, this should have been the easier part but unfortunately due to heavier traffic than usual I arrived only 20 minutes before time. Not too bad but more to come. The building called 'le Hub' is nicely renovated and provides the right environment for an IT group of companies like FRCI. I think they have currently 5 independent IT departments over there. Even the handling at the reception was straight forward, welcoming and at my ease. But then... first shock: "We don't have any exam registration for today." - Hm, that's nice... Here's my mail confirmation from Prometric. First attack successfully handled and the lady went off again to check their records. Next shock: A couple of minutes later, another guy tries to explain me that "the staff of the testing centre is already on vacation and the centre is officially closed." - Are you kidding me? Here's the official confirmation by Prometric, and I don't find it funny that I take a day off today only to hear this kind of blubbering nonsense. I thought that I'll be on the safe side choosing a company with a good reputation here on the island. Another 40 (!) minutes later, they finally come back to the waiting area with a pre-filled form about the test appointment. And finally, after an hour of waiting, discussing, restarting the testing PC, and lots of talk, I am allowed to sit down and take the exam. Exam details Well, you know the rules. Signing an NDA doesn't allow me to provide you any details about the questions or topics that have been covered. Please check out the official exam description, and you're on the right way. Sorry, guys... ;-) The result "Congratulations! You have passed this Microsoft Certification exam." - In general, I have to admit that the parts on HTML5 and CSS3 were the easiest after all, and that I have to get myself a little bit more familiar with certain Javascript features like class definitions, inheritance and data security. Anyway, exam passed - who cares about the details? Next goal Of course, the journey to Microsoft Certifications continues and my next goal is to pass exams 70-481 - Essentials of Developing Windows Store Apps using HTML5 and JavaScript and 70-482 - Advanced Windows Store App Development using HTML5 and JavaScript. This would allow me to achieve the certification of MCSD: Windows Store Apps using HTML5. I guess, during 2013 I'll be busy with various learning and teaching lessons.

    Read the article

  • Parsing T-SQL – The easy way

    - by Dave Ballantyne
    Every once in a while, I hit an issue that would require me to interrogate/parse some T-SQL code.  Normally, I would shy away from this and attempt to solve the problem in some other way.  I have written parsers before in the the past using LEX and YACC, and as much fun and awesomeness that path is,  I couldnt justify the time it would take. However, this week I have been faced with just such an issue and at the back of my mind I can remember reading through the SQLServer 2012 feature pack and seeing something called “Microsoft SQL Server 2012 Transact-SQL Language Service “.  This is described there as : “The SQL Server Transact-SQL Language Service is a component based on the .NET Framework which provides parsing validation and IntelliSense services for Transact-SQL for SQL Server 2012, SQL Server 2008 R2, and SQL Server 2008. “ Sounds just what I was after.  Documentation is very scant on this so dont take what follows as best practice or best use, just a practice and a use. Knowing what I was sort of looking for something, I found the relevant assembly in the gac which is the simply named ,’Microsoft.SqlServer.Management.SqlParser’. Even knowing that you wont find much in terms of documentation if you do a web-search, but you will find the MSDN documentation that list the members and methods etc… The “scanner”  class sounded the most appropriate for my needs as that is described as “Scans Transact-SQL searching for individual units of code or tokens.”. After a bit of poking, around the code i ended up with was something like [System.Reflection.Assembly]::LoadWithPartialName("Microsoft.SqlServer.Management.SqlParser") | Out-Null $ParseOptions = New-Object Microsoft.SqlServer.Management.SqlParser.Parser.ParseOptions $ParseOptions.BatchSeparator = 'GO' $Parser = new-object Microsoft.SqlServer.Management.SqlParser.Parser.Scanner($ParseOptions) $Sql = "Create Procedure MyProc as Select top(10) * from dbo.Table" $Parser.SetSource($Sql,0) $Token=[Microsoft.SqlServer.Management.SqlParser.Parser.Tokens]::TOKEN_SET $Start =0 $End = 0 $State =0 $IsEndOfBatch = $false $IsMatched = $false $IsExecAutoParamHelp = $false while(($Token = $Parser.GetNext([ref]$State ,[ref]$Start, [ref]$End, [ref]$IsMatched, [ref]$IsExecAutoParamHelp ))-ne [Microsoft.SqlServer.Management.SqlParser.Parser.Tokens]::EOF) { try{ ($TokenPrs =[Microsoft.SqlServer.Management.SqlParser.Parser.Tokens]$Token) | Out-Null $TokenPrs $Sql.Substring($Start,($end-$Start)+1) }catch{ $TokenPrs = $null } } As you can see , the $Sql variable holds the sql to be parsed , that is pushed into the $Parser object using SetSource,  and then we will use GetNext until the EOF token is returned.  GetNext will also return the Start and End character positions within the source string of the parsed text. This script’s output is : TOKEN_CREATE Create TOKEN_PROCEDURE Procedure TOKEN_ID MyProc TOKEN_AS as TOKEN_SELECT Select TOKEN_TOP top TOKEN_INTEGER 10 TOKEN_FROM from TOKEN_ID dbo TOKEN_TABLE Table note that the ‘(‘, ‘)’  and ‘*’ characters have returned a token type that is not present in the Microsoft.SqlServer.Management.SqlParser.Parser.Tokens Enum that has caused an error which has been caught in the catch block.  Fun, Fun ,Fun , Simple T-SQL Parsing.  Hope this helps someone in the same position,  let me know how you get on.

    Read the article

  • Numerically stable(ish) method of getting Y-intercept of mouse position?

    - by Fraser
    I'm trying to unproject the mouse position to get the position on the X-Z plane of a ray cast from the mouse. The camera is fully controllable by the user. Right now, the algorithm I'm using is... Unproject the mouse into the camera to get the ray: Vector3 p1 = Vector3.Unproject(new Vector3(x, y, 0), 0, 0, width, height, nearPlane, farPlane, viewProj; Vector3 p2 = Vector3.Unproject(new Vector3(x, y, 1), 0, 0, width, height, nearPlane, farPlane, viewProj); Vector3 dir = p2 - p1; dir.Normalize(); Ray ray = Ray(p1, dir); Then get the Y-intercept by using algebra: float t = -ray.Position.Y / ray.Direction.Y; Vector3 p = ray.Position + t * ray.Direction; The problem is that the projected position is "jumpy". As I make small adjustments to the mouse position, the projected point moves in strange ways. For example, if I move the mouse one pixel up, it will sometimes move the projected position down, but when I move it a second pixel, the project position will jump back to the mouse's location. The projected location is always close to where it should be, but it does not smoothly follow a moving mouse. The problem intensifies as I zoom the camera out. I believe the problem is caused by numeric instability. I can make minor improvements to this by doing some computations at double precision, and possibly abusing the fact that floating point calculations are done at 80-bit precision on x86, however before I start micro-optimizing this and getting deep into how the CLR handles floating point, I was wondering if there's an algorithmic change I can do to improve this? EDIT: A little snooping around in .NET Reflector on SlimDX.dll: public static Vector3 Unproject(Vector3 vector, float x, float y, float width, float height, float minZ, float maxZ, Matrix worldViewProjection) { Vector3 coordinate = new Vector3(); Matrix result = new Matrix(); Matrix.Invert(ref worldViewProjection, out result); coordinate.X = (float) ((((vector.X - x) / ((double) width)) * 2.0) - 1.0); coordinate.Y = (float) -((((vector.Y - y) / ((double) height)) * 2.0) - 1.0); coordinate.Z = (vector.Z - minZ) / (maxZ - minZ); TransformCoordinate(ref coordinate, ref result, out coordinate); return coordinate; } // ... public static void TransformCoordinate(ref Vector3 coordinate, ref Matrix transformation, out Vector3 result) { Vector3 vector; Vector4 vector2 = new Vector4 { X = (((coordinate.Y * transformation.M21) + (coordinate.X * transformation.M11)) + (coordinate.Z * transformation.M31)) + transformation.M41, Y = (((coordinate.Y * transformation.M22) + (coordinate.X * transformation.M12)) + (coordinate.Z * transformation.M32)) + transformation.M42, Z = (((coordinate.Y * transformation.M23) + (coordinate.X * transformation.M13)) + (coordinate.Z * transformation.M33)) + transformation.M43 }; float num = (float) (1.0 / ((((transformation.M24 * coordinate.Y) + (transformation.M14 * coordinate.X)) + (coordinate.Z * transformation.M34)) + transformation.M44)); vector2.W = num; vector.X = vector2.X * num; vector.Y = vector2.Y * num; vector.Z = vector2.Z * num; result = vector; } ...which seems to be a pretty standard method of unprojecting a point from a projection matrix, however this serves to introduce another point of possible instability. Still, I'd like to stick with the SlimDX Unproject routine rather than writing my own unless it's really necessary.

    Read the article

  • Non use of persisted data

    - by Dave Ballantyne
    Working at a client site, that in itself is good to say, I ran into a set of circumstances that made me ponder, and appreciate, the optimizer engine a bit more. Working on optimizing a stored procedure, I found a piece of code similar to : select BillToAddressID, Rowguid, dbo.udfCleanGuid(rowguid) from sales.salesorderheaderwhere BillToAddressID = 985 A lovely scalar UDF was being used,  in actuality it was used as part of the WHERE clause but simplified here.  Normally I would use an inline table valued function here, but in this case it wasn't a good option. So this seemed like a pretty good case to use a persisted column to improve performance. The supporting index was already defined as create index idxBill on sales.salesorderheader(BillToAddressID) include (rowguid) and the function code is Create Function udfCleanGuid(@GUID uniqueidentifier)returns varchar(255)with schemabindingasbegin Declare @RetStr varchar(255) Select @RetStr=CAST(@Guid as varchar(255)) Select @RetStr=REPLACE(@Retstr,'-','') return @RetStrend Executing the Select statement produced a plan of : Nothing surprising, a seek to find the data and compute scalar to execute the UDF. Lets get optimizing and remove the UDF with a persisted column Alter table sales.salesorderheaderadd CleanedGuid as dbo.udfCleanGuid(rowguid)PERSISTED A subtle change to the SELECT statement… select BillToAddressID,CleanedGuid from sales.salesorderheaderwhere BillToAddressID = 985 and our new optimized plan looks like… Not a lot different from before!  We are using persisted data on our table, where is the lookup to fetch it ?  It didnt happen,  it was recalculated.  Looking at the properties of the relevant Compute Scalar would confirm this ,  but a more graphic example would be shown in the profiler SP:StatementCompleted event. Why did the lookup happen ? Remember the index definition,  it has included the original guid to avoid the lookup.  The optimizer knows this column will be passed into the UDF, run through its logic and decided that to recalculate is cheaper than the lookup.  That may or may not be the case in actuality,  the optimizer has no idea of the real cost of a scalar udf.  IMO the default cost of a scalar UDF should be seen as a lot higher than it is, since they are invariably higher. Knowing this, how do we avoid the function call?  Dropping the guid from the index is not an option, there may be other code reliant on it.   We are left with only one real option,  add the persisted column into the index. drop index Sales.SalesOrderHeader.idxBillgocreate index idxBill on sales.salesorderheader(BillToAddressID) include (rowguid,cleanedguid) Now if we repeat the statement select BillToAddressID,CleanedGuid from sales.salesorderheaderwhere BillToAddressID = 985 We still have a compute scalar operator, but this time it wasnt used to recalculate the persisted data.  This can be confirmed with profiler again. The takeaway here is,  just because you have persisted data dont automatically assumed that it is being used.

    Read the article

  • Tetris Movement - Implementation

    - by James Brauman
    Hi gamedev, I'm developing a Tetris clone and working on the input at the moment. When I was prototyping, movement was triggered by releasing a directional key. However, in most Tetris games I've played the movement is a bit more complex. When a directional key is pressed, the shape moves one space in that direction. After a short interval, if the key is still held down, the shape starts moving in the direction continuously until the key is released. In the case of the down key being pressed, there is no pause between the initial movement and the subsequent continuous movement. I've come up with a solution, and it works well, but it's totally over-engineered. Hey, at least I can recognize when things are getting silly, right? :) public class TetrisMover { List registeredKeys; Dictionary continuousPressedTime; Dictionary totalPressedTime; Dictionary initialIntervals; Dictionary continousIntervals; Dictionary keyActions; Dictionary initialActionDone; KeyboardState currentKeyboardState; public TetrisMover() { *snip* } public void Update(GameTime gameTime) { currentKeyboardState = Keyboard.GetState(); foreach (Keys currentKey in registeredKeys) { if (currentKeyboardState.IsKeyUp(currentKey)) { continuousPressedTime[currentKey] = TimeSpan.Zero; totalPressedTime[currentKey] = TimeSpan.Zero; initialActionDone[currentKey] = false; } else { if (initialActionDone[currentKey] == false) { keyActions[currentKey](); initialActionDone[currentKey] = true; } totalPressedTime[currentKey] += gameTime.ElapsedGameTime; if (totalPressedTime[currentKey] = initialIntervals[currentKey]) { continuousPressedTime[currentKey] += gameTime.ElapsedGameTime; if (continuousPressedTime[currentKey] = continousIntervals[currentKey]) { keyActions[currentKey](); continuousPressedTime[currentKey] = TimeSpan.Zero; } } } } } public void RegisterKey(Keys key, TimeSpan initialInterval, TimeSpan continuousInterval, Action keyAction) { if (registeredKeys.Contains(key)) throw new InvalidOperationException( string.Format("The key %s is already registered.", key)); registeredKeys.Add(key); continuousPressedTime.Add(key, TimeSpan.Zero); totalPressedTime.Add(key, TimeSpan.Zero); initialIntervals.Add(key, initialInterval); continousIntervals.Add(key, continuousInterval); keyActions.Add(key, keyAction); initialActionDone.Add(key, false); } public void UnregisterKey(Keys key) { *snip* } } I'm updating it every frame, and this is how I'm registering keys for movement: tetrisMover.RegisterKey( Keys.Left, keyHoldStartSpecialInterval, keyHoldMovementInterval, () = { Move(Direction.Left); }); tetrisMover.RegisterKey( Keys.Right, keyHoldStartSpecialInterval, keyHoldMovementInterval, () = { Move(Direction.Right); }); tetrisMover.RegisterKey( Keys.Down, TimeSpan.Zero, keyHoldMovementInterval, () = { PerformGravity(); }); Issues that this doesn't address: If both left and right are held down, the shape moves back and forth really quick. If a directional key is held down and the turn finishes and the shape is replaced by a new one, the new one will move quickly in that direction instead of the little pause it is supposed to have. I could fix the issues, but I think it will make the solution even worse. How would you implement this?

    Read the article

  • User password rejected on login screen but accepted on text console login

    - by MadsirR
    I had to force shutdown my Ubuntu 12.04 64-bit, after which I restarted and tried to log in as a normal user, which was rejected several times. I then logged in as guest and tty to my regular account with use of my normal password, which succeeded. (So the password is still valid.) How can I gain access again via the normal login procedure (welcome screen)? Update: When I tried to log on with my new password, it again was denied. When I deliberately tried to log on with a faulty password, an error message came back, saying: Access denied - wrong password. I suppose, the first time the password was not rejected, but the procedure was aborted for some reason. Some additional info after trying to find a solution: I am conviced it is a Compiz-issue. Why? before this happened, all sessions came to a grinding halt, regardless of being logged on in a 2D or 3d environment. I found a link saying that I should remove Compiz and proceed in a 2D environment, which initiall worked without a glitch, until my system went into a state of total obivium. Only after that, the above mentioned troubles appeared. In the meantime I have happened to find a thread with reference 17381, describing exactly what I have experienced. For now, I will try to cure this situation (later this week) and revert with the results, hopefully to close this post. In the meantime I cordially thank you all, even if you didn't kill the problem; you gave me the inspiration to look further and find a possible cure. Update2: After 15 hrs of trial-and-error I callled it quits (When I decided to tackle this problem, I've given myself 12 hrs, to avoid massive loss of time.) I decided to re-install Precise, since the "point 1" version has become availabe. Log-in is back to normal, as is the graphic environment. Response to mouse input is stil appalling, especially when I have a series of screens open as "children"of a "parent" screen. It still completely locks up. I have installed Enlightenment, Gnome classic, Gnome 3, Cinnamon and they all behave in a similar fashion. FOR THOSE WHO NEED A WAY-OUT IN SITUATIONS OF THE LIKE: Open a terminal with [Ctrl+Alt+F2]. Type [sudo killall Firefox] (or whatever application you wish to terminate). Key in your password. Return to your graphical screen with [Ctrl+Alt+F7], and Bob's your uncle. Just re-open Firefox like nothing happened. Next time you are stuck: [Ctrl+Alt+F2], upward arrow till you meet the command of your desire, [Ctrl+Alt+F7], etcetera. Hope this is of help. My next move will be to upgrade the kernel to 3.4 from the repositories for 12.10. However, since this entails a totally new situation, I will start a new thread on this site to avoid topic pollution I will keep you posted. Still.

    Read the article

  • My 2D collision code does not work as expected. How do I fix it?

    - by farmdve
    I have a simple 2D game with a tile-based map. I am new to game development, I followed the LazyFoo tutorials on SDL. The tiles are in a bmp file, but each tile inside it corresponds to an internal number of the type of tile(color, or wall). The game is simple, but the code is a lot so I can only post snippets. // Player moved out of the map if((player.box.x < 0)) player.box.x += GetVelocity(player, 0); if((player.box.y < 0)) player.box.y += GetVelocity(player, 1); if((player.box.x > (LEVEL_WIDTH - DOT_WIDTH))) player.box.x -= GetVelocity(player, 0); if((player.box.y > (LEVEL_HEIGHT - DOT_HEIGHT))) player.box.y -= GetVelocity(player, 1); // Now that we are here, we check for collisions if(touches_wall(player.box)) { if(player.box.x < player.prev_x) { player.box.x += GetVelocity(player, 0); } if(player.box.x > player.prev_x) { player.box.x -= GetVelocity(player, 0); } if(player.box.y < player.prev_y) { player.box.y += GetVelocity(player, 1); } if(player.box.y > player.prev_y) { player.box.y -= GetVelocity(player, 1); } } player.prev_x = player.box.x; player.prev_y = player.box.y; Let me explain, player is a structure with the following contents typedef struct { Rectangle box; //Player position on a map(tile or whatever). int prev_x, prev_y; // Previous positions int key_press[3]; // Stores which key was pressed/released. Limited to three keys. E.g Left,right and perhaps jump if possible in 2D int velX, velY; // Velocity for X and Y coordinate. //Health int health; bool main_character; uint32_t jump_ticks; } Player; And Rectangle is just a typedef of SDL_Rect. GetVelocity is a function that according to the second argument, returns the velocity for the X or Y axis. This code I have basically works, however inside the if(touches_wall(player.box)) if statement, I have 4 more. These 4 if statements are responsible for detecting collision on all 4 sides(up,down,left,right). However, they also act as a block for any other movement. Example: I move down the object and collide with the wall, as I continue to move down and still collide with the wall, I wish to move left or right, which is indeed possible(not to mention in 3D games), but remember the 4 if statements? They are preventing me from moving anywhere. The original code on the LazyFoo Productions website has no problems, but it was written in C++, so I had to rewrite most of it to work, which is probably where the problem comes from. I also use a different method of moving, than the one in the examples. Of course, that was just an example. I wish to be able to move no matter at which wall I collide. Before this bit of code, I had another one that had more logic in there, but it was flawed.

    Read the article

  • PowerShell Script To Find Where SharePoint 2007 Features Are Activated

    - by Brian T. Jackett
    Recently I posted a script to find where SharePoint 2010 Features Are Activated.  I built the original version to use SharePoint 2010 PowerShell commandlets as that saved me a number of steps for filtering and gathering features at each level.  If there was ever demand for a 2007 version I could modify the script to handle that by using the object model instead of commandlets.  Just the other week a fellow SharePoint PFE Jason Gallicchio had a customer asking about a version for SharePoint 2007.  With a little bit of work I was able to convert the script to work against SharePoint 2007.   Solution    Below is the converted script that works against a SharePoint 2007 farm.  Note: There appears to be a bug with the 2007 version that does not give accurate results against a SharePoint 2010 farm.  I ran the 2007 version against a 2010 farm and got fewer results than my 2010 version of the script.  Discussing with some fellow PFEs I think the discrepancy may be due to sandboxed features, a new concept in SharePoint 2010.  I have not had enough time to test or confirm.  For the time being only use the 2007 version script against SharePoint 2007 farms and the 2010 version against SharePoint 2010 farms.    Note: This script is not optimized for medium to large farms.  In my testing it took 1-3 minutes to recurse through my demo environment.  This script is provided as-is with no warranty.  Run this in a smaller dev / test environment first. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 function Get-SPFeatureActivated { # see full script for help info, removed for formatting [CmdletBinding()] param(     [Parameter(position = 1, valueFromPipeline=$true)]     [string]     $Identity )#end param     Begin     {         # load SharePoint assembly to access object model         [void][System.Reflection.Assembly]::LoadWithPartialName("Microsoft.SharePoint")             # declare empty array to hold results. Will add custom member for Url to show where activated at on objects returned from Get-SPFeature.         $results = @()                 $params = @{}     }     Process     {         if([string]::IsNullOrEmpty($Identity) -eq $false)         {             $params = @{Identity = $Identity}         }                 # create hashtable of farm features to lookup definition ids later         $farm = [Microsoft.SharePoint.Administration.SPFarm]::Local                         # check farm features         $results += ($farm.FeatureDefinitions | Where-Object {$_.Scope -eq "Farm"} | Where-Object {[string]::IsNullOrEmpty($Identity) -or ($_.DisplayName -eq $Identity)} |                          % {Add-Member -InputObject $_ -MemberType noteproperty -Name Url -Value ([string]::Empty) -PassThru} |                          Select-Object -Property Scope, DisplayName, Id, Url)                 # check web application features         $contentWebAppServices = $farm.services | ? {$_.typename -like "Windows SharePoint Services Web Application"}                 foreach($webApp in $contentWebAppServices.WebApplications)         {             $results += ($webApp.Features | Select-Object -ExpandProperty Definition | Where-Object {[string]::IsNullOrEmpty($Identity) -or ($_.DisplayName -eq $Identity)} |                          % {Add-Member -InputObject $_ -MemberType noteproperty -Name Url -Value $webApp.GetResponseUri(0).AbsoluteUri -PassThru} |                          Select-Object -Property Scope, DisplayName, Id, Url)                         # check site collection features in current web app             foreach($site in ($webApp.Sites))             {                 $results += ($site.Features | Select-Object -ExpandProperty Definition | Where-Object {[string]::IsNullOrEmpty($Identity) -or ($_.DisplayName -eq $Identity)} |                                  % {Add-Member -InputObject $_ -MemberType noteproperty -Name Url -Value $site.Url -PassThru} |                                  Select-Object -Property Scope, DisplayName, Id, Url)                                 # check site features in current site collection                 foreach($web in ($site.AllWebs))                 {                     $results += ($web.Features | Select-Object -ExpandProperty Definition | Where-Object {[string]::IsNullOrEmpty($Identity) -or ($_.DisplayName -eq $Identity)} |                                      % {Add-Member -InputObject $_ -MemberType noteproperty -Name Url -Value $web.Url -PassThru} |                                      Select-Object -Property Scope, DisplayName, Id, Url)                                                        $web.Dispose()                 }                 $site.Dispose()             }         }     }     End     {         $results     } } #end Get-SPFeatureActivated Get-SPFeatureActivated   Conclusion    I have posted this script to the TechNet Script Repository (click here).  As always I appreciate any feedback on scripts.  If anyone is motivated to run this 2007 version script against a SharePoint 2010 to see if they find any differences in number of features reported versus what they get with the 2010 version script I’d love to hear from you.         -Frog Out

    Read the article

  • Virtualized data centre&ndash;Part three: Architecture

    - by marc dekeyser
    Having the basics (like discussed in the previous articles) is all good and well, but how do we get started on this?! It can be quite daunting after all!   From my own point of view I can absolutely confirm your worries and concerns, but also tell you that it is not as hard as it seems! Deciding on what kind of motherboard to buy, processor and how much memory is an activity you will spend quite some time doing research on. And that is not even mentioning storage! All in all it comes down to setting you expectations and your budget. Probably adjusting your expectations according to your budget :). Processors As a rule of thumb you want VT-D (virtualization) technology built in to the processor allowing you to have 64 bit machines running on your host. Memory The more the better! If you are building a home lab don’t bother with ECC unless you are going to run machines that absolutely should be on all the time and your comfort depends on it! Motherboard Depends on what you are going to do with storage: If you are going the NAS way then the number of SATA port/RAID capabilities do not really matter. If you decide to have a single server with lots of dedicated storage it obviously matters how much SATA ports you will have, alternatively you could use a RAID controller (but these set you back a pretty penny if you want one. DELL 6i’s are usually available for a good bargain if you can find one!). Easiest is to get one with a built-in graphics card (on-board) as you are just adding more heat, power usage and possible points of failure. Networking Just like your choice of motherboard the networking side tends to depend on how you want to go. A single virtualization  host with local storage can usually get away with having a single network card, a cluster or server which uses iSCSI storage tends to have more than one teamed up :). Storage The dreaded beast from the dark! The horror which lives in the forest! The most difficult decision you are going to make in the building of your lab. Why you might ask? Simple my friend, having the right choice of storage can make or break your virtualization solution. The performance of you storage choice will have an important impact on the responsiveness of your virtual machines and the deployment of new machines. It also makes a run with your budget! If you decide to go the NAS route you will be dropping a lot more money than if you would be having just a bunch of disks sitting in a server and manually distributing the virtual machines over the disks. Platform I’m a Microsoftee so Hyper-V is a dead giveaway for me. If you are interested in using VMware I won’t stop you but the rest of my posts will be oriented on Server 2012 Hyper-V (aka 3.0)! What did I use? Before someone asks me this in the comments I’ll give you a quick run down of what I am using. - Intel 2.4 quad core processors (i something something) - 24 GB DDR3 Memory - Single disk in each server (might look at this as I move the servers to 2012) - Synology DS1812+ NAS - 3 network interfaces where possible - HP1800 procurve managed switch I decided to spring for the NAS as I will also be using it for backups and media storage (which is working out quite nicely with my Xbox 360 I must say). At the time of building my 2 boxes (over a year and a half ago) these set me back about 900 euros each so I can image you can build the same or better for a lower price. Next article will be diagramming what I want to achieve and starting a build on the Hyper V 3.0 cluster!

    Read the article

< Previous Page | 700 701 702 703 704 705 706 707 708 709 710 711  | Next Page >