Search Results

Search found 23890 results on 956 pages for 'issue'.

Page 905/956 | < Previous Page | 901 902 903 904 905 906 907 908 909 910 911 912  | Next Page >

  • IIS 7.5 on Windows Server 2008 R2 refusing to create PASSIVE MODE FTP connections

    - by Campbell
    I'm attempting to get an FTP client written in perl to transfer files from an IIS 7.5 FTP server using passive mode. I've configured the FTP server as per instructions and have also configured Windows Firewall to allow this type of traffic. I have validated that the firewall is behaviong correctly by checking to ensure there are no blocked packets in the logs. I have verified the that FTP control channel is being opened on Port 21. I believe the client is being told by IIS which port to connect on for passive mode and IIS is refusing to allow this connection. The perl log looks like: C:\cygwin\Perl\lib\FMT>perl FTPTest.pl Net::FTP>>> Net::FTP(2.77) Net::FTP>>> Exporter(5.64_01) Net::FTP>>> Net::Cmd(2.29) Net::FTP>>> IO::Socket::INET(1.31) Net::FTP>>> IO::Socket(1.31) Net::FTP>>> IO::Handle(1.28) Net::FTP=GLOB(0x20abac0)<<< 220 Microsoft FTP Service Net::FTP=GLOB(0x20abac0)>>> USER ftpuser Net::FTP=GLOB(0x20abac0)<<< 331 Password required for ftpuser. Net::FTP=GLOB(0x20abac0)>>> PASS .... Net::FTP=GLOB(0x20abac0)<<< 230 User logged in. Net::FTP=GLOB(0x20abac0)>>> CWD /Logs Net::FTP=GLOB(0x20abac0)<<< 250 CWD command successful. Net::FTP=GLOB(0x20abac0)>>> PASV Net::FTP=GLOB(0x20abac0)<<< 227 Entering Passive Mode (xx,xxx,xxx,xxx,160,41). Net::FTP=GLOB(0x20abac0)>>> RETR filename.txt Can't use an undefined value as a symbol reference at C:/Utilities/strawberryper l/perl/lib/Net/FTP/dataconn.pm line 54. IIS logs look as follows: 2010-10-02 17:40:06 xx.xxx.xx.xx - yy.y.yy.yy ControlChannelOpened - - 0 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a - - 2010-10-02 17:40:06 xx.xxx.xx.xx - yy.y.yy.yy USER ftpuser 331 0 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a - - 2010-10-02 17:40:06 xx.xxx.xx.xx MACHINENAME\ftpuser yy.y.yy.yy PASS *** 230 0 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a / - 2010-10-02 17:40:06 xx.xxx.xx.xx MACHINENAME\ftpuser yy.y.yy.yy CWD /Logs 250 0 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a /Logs - 2010-10-02 17:40:06 xx.xxx.xx.xx MACHINENAME\ftpuser yy.y.yy.yy PASV - 227 0 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a - - 2010-10-02 17:40:27 - MACHINENAME\ftpuser zz.z.zz.zzz 41001 DataChannelClosed - - 64 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a - - 2010-10-02 17:40:27 xx.xxx.xx.xx MACHINENAME\ftpuser yy.y.yy.yy ControlChannelClosed - - 64 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a - - 2010-10-02 17:40:27 xx.xxx.xx.xx MACHINENAME\ftpuser yy.y.yy.yy RETR filename.txt 550 1236 0 27a48c9b-9dce-4770-8bcf-fc89f2569b1a filename.txt - We've managed to see this issue with other FTP clients also, I don't think its something funny in Perl. I've been informed that this works fine in the IIS 6 FTP server. I'm wondering if there is something we're missing here.

    Read the article

  • linux routing bug?

    - by Balázs Pozsár
    I have been struggling with this not easily reproducible issue since a while. I am using linux kernel v3.1.0, and sometimes routing to a few IP addresses does not work. What seems to happen is that instead of sending the packet to the gateway, the kernel treats the destination address as local, and tries to gets its MAC address via ARP. For example, now my current IP address is 172.16.1.104/24, the gateway is 172.16.1.254: # ifconfig eth0 eth0 Link encap:Ethernet HWaddr 00:1B:63:97:FC:DC inet addr:172.16.1.104 Bcast:172.16.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:230772 errors:0 dropped:0 overruns:0 frame:0 TX packets:171013 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:191879370 (182.9 Mb) TX bytes:47173253 (44.9 Mb) Interrupt:17 # route -n Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 172.16.1.254 0.0.0.0 UG 0 0 0 eth0 172.16.1.0 0.0.0.0 255.255.255.0 U 1 0 0 eth0 I can ping a few addresses, but not 172.16.0.59: # ping -c1 172.16.1.254 PING 172.16.1.254 (172.16.1.254) 56(84) bytes of data. 64 bytes from 172.16.1.254: icmp_seq=1 ttl=64 time=0.383 ms --- 172.16.1.254 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 0.383/0.383/0.383/0.000 ms root@pozsybook:~# ping -c1 172.16.0.1 PING 172.16.0.1 (172.16.0.1) 56(84) bytes of data. 64 bytes from 172.16.0.1: icmp_seq=1 ttl=63 time=5.54 ms --- 172.16.0.1 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 5.545/5.545/5.545/0.000 ms root@pozsybook:~# ping -c1 172.16.0.2 PING 172.16.0.2 (172.16.0.2) 56(84) bytes of data. 64 bytes from 172.16.0.2: icmp_seq=1 ttl=62 time=7.92 ms --- 172.16.0.2 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 7.925/7.925/7.925/0.000 ms root@pozsybook:~# ping -c1 172.16.0.59 PING 172.16.0.59 (172.16.0.59) 56(84) bytes of data. From 172.16.1.104 icmp_seq=1 Destination Host Unreachable --- 172.16.0.59 ping statistics --- 1 packets transmitted, 0 received, +1 errors, 100% packet loss, time 0ms When trying to ping 172.16.0.59, I can see in tcpdump that an ARP req was sent: # tcpdump -n -i eth0|grep ARP tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on eth0, link-type EN10MB (Ethernet), capture size 96 bytes 15:25:16.671217 ARP, Request who-has 172.16.0.59 tell 172.16.1.104, length 28 and /proc/net/arp has an incomplete entry for 172.16.0.59: # grep 172.16.0.59 /proc/net/arp 172.16.0.59 0x1 0x0 00:00:00:00:00:00 * eth0 Please note, that 172.16.0.59 is accessible from this LAN from other computers. Does anyone have any idea of what's going on? Thanks. update: replies to the comments below: there are no interfaces besides eth0 and lo the ARP req cannot be seen on the other end, but that's how it should work. the main problem is that an ARP req should not even be sent at the first place the problem persist even if I add an explicit route with the command "route add -host 172.16.0.59 gw 172.16.1.254 dev eth0"

    Read the article

  • Cannot connect to MySQL Server on RHEL 5.7

    - by Jeffrey Wong
    I have a standard MySQL Server running on Red hat 5.7. I have edited /etc/my.cnf to specify the bind address as my server's public IP address. [mysqld] datadir=/var/lib/mysql socket=/var/lib/mysql/mysql.sock user=mysql # Default to using old password format for compatibility with mysql 3.x # clients (those using the mysqlclient10 compatibility package). old_passwords=1 # Disabling symbolic-links is recommended to prevent assorted security risks ; # to do so, uncomment this line: # symbolic-links=0 [mysqld_safe] log-error=/var/log/mysqld.log pid-file=/var/run/mysqld/mysqld.pid bind-address=171.67.88.25 port=3306 And I have also restarted my firewall sudo /sbin/iptables -A INPUT -i eth0 -p tcp --destination-port 3306 -j ACCEPT /sbin/service iptables save The network administrator has already opened port 3306 for this box. When connecting from a remote computer (running Ubuntu 10.10, server is running RHEL 5.7), I issue mysql -u jeffrey -p --host=171.67.88.25 --port=3306 --socket=/var/lib/mysql/mysql.sock but receive a ERROR 2003 (HY000): Can't connect to MySQL server on '171.67.88.25' (113). I've noticed that the socket file /var/lib/mysql/mysql.sock is blank. Should this be the case? UPDATE The result of netstat -an | grep 3306 tcp 0 0 0.0.0.0:3306 0.0.0.0:* LISTEN Result of sudo netstat -tulpen Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State User Inode PID/Program name tcp 0 0 127.0.0.1:2208 0.0.0.0:* LISTEN 0 7602 3168/hpiod tcp 0 0 0.0.0.0:3306 0.0.0.0:* LISTEN 27 7827 3298/mysqld tcp 0 0 0.0.0.0:111 0.0.0.0:* LISTEN 0 5110 2802/portmap tcp 0 0 0.0.0.0:8787 0.0.0.0:* LISTEN 0 8431 3326/rserver tcp 0 0 0.0.0.0:915 0.0.0.0:* LISTEN 0 5312 2853/rpc.statd tcp 0 0 0.0.0.0:22 0.0.0.0:* LISTEN 0 7655 3188/sshd tcp 0 0 127.0.0.1:631 0.0.0.0:* LISTEN 0 7688 3199/cupsd tcp 0 0 127.0.0.1:25 0.0.0.0:* LISTEN 0 8025 3362/sendmail: acce tcp 0 0 127.0.0.1:2207 0.0.0.0:* LISTEN 0 7620 3173/python udp 0 0 0.0.0.0:909 0.0.0.0:* 0 5300 2853/rpc.statd udp 0 0 0.0.0.0:912 0.0.0.0:* 0 5309 2853/rpc.statd udp 0 0 0.0.0.0:68 0.0.0.0:* 0 4800 2598/dhclient udp 0 0 0.0.0.0:36177 0.0.0.0:* 70 8314 3476/avahi-daemon: udp 0 0 0.0.0.0:5353 0.0.0.0:* 70 8313 3476/avahi-daemon: udp 0 0 0.0.0.0:111 0.0.0.0:* 0 5109 2802/portmap udp 0 0 0.0.0.0:631 0.0.0.0:* 0 7691 3199/cupsd Result of sudo /sbin/iptables -L -v -n Chain INPUT (policy ACCEPT 0 packets, 0 bytes) pkts bytes target prot opt in out source destination 6373 2110K RH-Firewall-1-INPUT all -- * * 0.0.0.0/0 0.0.0.0/0 Chain FORWARD (policy ACCEPT 0 packets, 0 bytes) pkts bytes target prot opt in out source destination 0 0 RH-Firewall-1-INPUT all -- * * 0.0.0.0/0 0.0.0.0/0 Chain OUTPUT (policy ACCEPT 1241 packets, 932K bytes) pkts bytes target prot opt in out source destination Chain RH-Firewall-1-INPUT (2 references) pkts bytes target prot opt in out source destination 572 861K ACCEPT all -- lo * 0.0.0.0/0 0.0.0.0/0 1 28 ACCEPT icmp -- * * 0.0.0.0/0 0.0.0.0/0 icmp type 255 0 0 ACCEPT esp -- * * 0.0.0.0/0 0.0.0.0/0 0 0 ACCEPT ah -- * * 0.0.0.0/0 0.0.0.0/0 46 6457 ACCEPT udp -- * * 0.0.0.0/0 224.0.0.251 udp dpt:5353 0 0 ACCEPT udp -- * * 0.0.0.0/0 0.0.0.0/0 udp dpt:631 0 0 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 tcp dpt:631 782 157K ACCEPT all -- * * 0.0.0.0/0 0.0.0.0/0 state RELATED,ESTABLISHED 2 120 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:22 0 0 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:443 0 0 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:23 0 0 ACCEPT tcp -- * * 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:80 4970 1086K REJECT all -- * * 0.0.0.0/0 0.0.0.0/0 reject-with icmp-host-prohibited Result of nmap -P0 -p3306 171.67.88.25 Host is up (0.027s latency). PORT STATE SERVICE 3306/tcp filtered mysql Nmap done: 1 IP address (1 host up) scanned in 0.09 seconds Solution When everything else fails, go GUI! system-config-securitylevel and add port 3306. All done!

    Read the article

  • Facing issues in setting up VPN connection(IKEv1) using iphone (Defult Cisco VPN client) and Strongswan 4.5.0 server

    - by Kushagra Bhatnagar
    I am facing issues in setting up VPN connection(IKEv1) using iPhone (Defult Cisco VPN client) and Strongswan 4.5.0 server. The Strongswan server is running on Ubuntu Linux, which is connected to some wifi hotspot. This is the guide which was used. I generated CA, server and client certificate, with the only difference mentioned below. “While generating server certificate, as per link CN=vpn.strongswan.org instead of this I changed CN name to CN=192.168.43.212.” Once certificates are generated, following (clientCert.p12 and caCert.pem) are sent to mobile via mail and installed on iphone. After installation I notice that certificates are considered as trusted also. Below are the ip addresses assigned to various interfaces Linux server wlan0 interface ip where server is running: 192.168.43.212 Iphone eth0 interface ip address: 192.168.43.72. iphone is also attached with the same wifi hotspot. Below is the snapshot of client configurations. Description Strong swan Server 192.168.43.212 Account ipsecvpn Password ***** Use certificate ON Certificate client The above username and password are in sync with the ipsec.secrets file. I am using the following ipsec.conf configuration: # basic configuration config setup plutodebug=all # crlcheckinterval=600 # strictcrlpolicy=yes # cachecrls=yes nat_traversal=yes # charonstart=yes plutostart=yes # Add connections here. # Sample VPN connections conn ios1 keyexchange=ikev1 authby=xauthrsasig xauth=server left=%defaultroute leftsubnet=0.0.0.0/0 leftfirewall=yes leftcert=serverCert.pem right=192.168.43.72 rightsubnet=10.0.0.0/24 rightsourceip=10.0.0.2 rightcert=clientCert.pem pfs=no auto=add With the above configurations when I enable VPN on iphone, it says Could not able to verify server certificate. I ran Wireshark on a Linux server and observe that initially some ISAKMP message exchanges happens between client and server, which are successful but before authorization, client is sending some informational message and soon after this client is showing error as popup Could not able to verify server certificate. Capture logs on Strongswan server and in server logs below errors are observed: From auth.log Apr 25 20:16:08 Linux pluto[4025]: | ISAKMP version: ISAKMP Version 1.0 Apr 25 20:16:08 Linux pluto[4025]: | exchange type: ISAKMP_XCHG_INFO Apr 25 20:16:08 Linux pluto[4025]: | flags: ISAKMP_FLAG_ENCRYPTION Apr 25 20:16:08 Linux pluto[4025]: | message ID: 9d 1a ea 4d Apr 25 20:16:08 Linux pluto[4025]: | length: 76 Apr 25 20:16:08 Linux pluto[4025]: | ICOOKIE: f6 b7 06 b2 b1 84 5b 93 Apr 25 20:16:08 Linux pluto[4025]: | RCOOKIE: 86 92 a0 c2 a6 2f ac be Apr 25 20:16:08 Linux pluto[4025]: | peer: c0 a8 2b 48 Apr 25 20:16:08 Linux pluto[4025]: | state hash entry 8 Apr 25 20:16:08 Linux pluto[4025]: | state object not found Apr 25 20:16:08 Linux pluto[4025]: **packet from 192.168.43.72:500: Informational Exchange is for an unknown (expired?) SA** Apr 25 20:16:08 Linux pluto[4025]: | next event EVENT_RETRANSMIT in 8 seconds for #8 Apr 25 20:16:16 Linux pluto[4025]: | Apr 25 20:16:16 Linux pluto[4025]: | *time to handle event Apr 25 20:16:16 Linux pluto[4025]: | event after this is EVENT_RETRANSMIT in 2 seconds Apr 25 20:16:16 Linux pluto[4025]: | handling event EVENT_RETRANSMIT for 192.168.43.72 "ios1" #8 Apr 25 20:16:16 Linux pluto[4025]: | sending 76 bytes for EVENT_RETRANSMIT through wlan0 to 192.168.43.72:500: Apr 25 20:16:16 Linux pluto[4025]: | a6 a5 86 41 4b fb ff 99 c9 18 34 61 01 7b f1 d9 Apr 25 20:16:16 Linux pluto[4025]: | 08 10 06 01 e9 1c ea 60 00 00 00 4c ba 7d c8 08 Apr 25 20:16:16 Linux pluto[4025]: | 13 47 95 18 19 31 45 30 2e 22 f9 4d 85 2c 27 bc Apr 25 20:16:16 Linux pluto[4025]: | 9e 9b e1 ae 1e 35 51 6f ab 80 f5 73 3c 15 8d 20 Apr 25 20:16:16 Linux pluto[4025]: | 4b 46 47 86 50 24 3f 13 15 7d d5 17 Apr 25 20:16:16 Linux pluto[4025]: | inserting event EVENT_RETRANSMIT, timeout in 40 seconds for #8 Apr 25 20:16:16 Linux pluto[4025]: | next event EVENT_RETRANSMIT in 2 seconds for #10 Apr 25 20:16:16 Linux pluto[4025]: | rejected packet: Apr 25 20:16:16 Linux pluto[4025]: | Apr 25 20:16:16 Linux pluto[4025]: | control: Apr 25 20:16:16 Linux pluto[4025]: | 30 00 00 00 00 00 00 00 00 00 00 00 0b 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | 6f 00 00 00 02 03 03 00 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | 02 00 00 00 c0 a8 2b 48 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | name: Apr 25 20:16:16 Linux pluto[4025]: | 02 00 01 f4 c0 a8 2b 48 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: **ERROR: asynchronous network error report on wlan0 for message to 192.168.43.72 port 500, complainant 192.168.43.72: Connection refused [errno 111, origin ICMP type 3 code 3 (not authenticated)]** Anybody please provide some update about this error and how to solve this issue.

    Read the article

  • TV not detected by Windows/VGA - when there is a WHDI device in the signal chain

    - by ashwalk
    I'm at my wit's end with this one... I had an EVGA GTS 250, and I used to plug it's HDMI out into a WHDI sender, which transmitted to its corresponding WHDI receiver 15ft away, which then connected to a Samsung LN40D LCD TV through another HDMI cable. PC/VGA < [hdmi cable] < WHDI sender <[air] WHDI receiver < [hdmi cable] < TV It was perfect, stable, no perceivable latency. I just plugged everything the first time and it worked instantly. It sent 5.1 audio, and Windows/nVidia Control Center detected the TV by its name. The WHDI device is this one: http://goo.gl/Q8iWI5 Now I bought an EVGA GTX 650, and WHDI doesn't work anymore. Both Windows and nVidia Control Center won't detect the TV, only the monitor that's connected via DVI. The TV screen shows "TX202913 connected. Check video signal." on top of a black screen. Though the device is not the problem itself, just the fact that it's not allowing direct connection between PC and TV. I would bet that if put an AVR in its place I'd also have this issue. The HDMI on this new card works with other monitors. If I put the older card back, WHDI works normally. I have googled this for 5 months on and off. Once I bumped into a page that showed how to force a display device to always-on through registry edit. Once I restarted windows, the Tv (through WHDI) displayed my expanded or duplicated desktop at 1024x768 ONLY, and listed the display as "digital display". I could not change the resolution and it wouldn't playback audio (although the option was available at nVidia Control Center HDMI audio options, but did not work). This proves that there is no conflict between the devices, except that software-wise, Windows cannot, for the life of it, understand that there's a TV there to send video/audio to. Since this won't do (no audio, poor video), I reverted this regedit. It's also not an EDID problem within the TV, since when connected directly it works. The last weird bit of this saga is that today, I reminded of Windows' "Add Device" dialog, gave it a go, and a "Samsung Generic UPNP TV" showed up, which I promptly installed the drives for, rising to a climax of... ...NOTHING HAPPENING. As far as I can tell, it really didn't change anything other than using up a few kb in my main disc. I should also say that I looked a LOT into handshake problems and nothing applied either. Do any of you have an idea of what may be going on? I can't stand the thought of having a us$200 device not working because of the addition of a newer graphics card, when the much older one had no issues. There is absolutely NO REASON for this to happen. There is NO documentation on WHDI online. Apparently no one buys this stuff. For the same reason, no one responded to this same plea for help on NVidia and EVGA forums. Worst case, this can be a warning about this setup for people in the future. Thanx in advance.

    Read the article

  • NetBackup with VSS and Instant Recovery - Failing to delete old snapshots

    - by Jonathan Bourke
    We are attempting to implement Microsoft VSS for snap-shotting in our NetBackup 6.5.3.1 environment. The clients are both 32 & 64 bit Windows 2003 Server. Snapshot parameters are: Instant recovery is enabled Maximum snapshots = 1 Provider type = 1 (System) Snapshot attribute = 1 (Differential) All backups successfully complete, and VSS shadows are successfully created both for the snapshot backup and for the open files (shadow copy components). The Issue: NetBackup is not clearing or overwriting old snapshots with each successive backup. When we list shadows, and shadow storage, it is increasing and increasing. IT is not honouring the Maximum Snapshot setting. The Logs: The bpfis log doesn’t really appear to show any errors other than for methods which we are not employing (VxVM, Flashsnap, etc.). A section is as follows: 11:54:10.744 [348.4724] <2> logparams: D:\Program Files\Veritas\NetBackup\bin\bpfis.exe delete -nbu -id htpststr001.san.mgmt.det_1248918143 -bpstart_to 300 -bpend_to 300 -clnt htpststr001.san.mgmt.det 11:54:10.744 [348.4724] <4> bpfis: INF - BACKUP START 348 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: VfMS error 10; see following messages: 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: Non-fatal method error was reported 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: vfm_configure_fi_one: method: FlashSnap, type: FIM, function: FlashSnap_init 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: VfMS method error 3; see following message: 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: FlashSnap_init: Veritas Volume Manager not installed. 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: VfMS error 10; see following messages: 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: Non-fatal method error was reported 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: vfm_configure_fi_one: method: vxvm, type: FIM, function: vxvm_init 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: VfMS method error 3; see following message: 11:54:11.713 [348.4724] <8> onlfi_initialize_vfms: vxvm_init: Veritas Volume Manager not installed. 11:54:11.713 [348.4724] <4> onlfi_thaw: Thawing C:\ using snapshot method VSS. 11:54:11.713 [348.4724] <2> onlfi_vfms_logf: vfm_thaw: delete snapshot ... 11:54:11.744 [348.4724] <2> onlfi_vfms_logf: snapshot services: emcclariionfi:Thu Jul 30 2009 11:54:11.744000 <Thread id - 4724> Unable to import any login credentials for any appliances. 11:54:11.760 [348.4724] <2> onlfi_vfms_logf: snapshot services: hpevafi:Thu Jul 30 2009 11:54:11.760000 <Thread id - 4724> CHpEvaPlugin::init: CLI tool is not installed. 11:54:11.760 [348.4724] <2> onlfi_vfms_logf: snapshot services: hpmsafi:Thu Jul 30 2009 11:54:11.760000 <Thread id - 4724> No array mangement credentials are available in configuration file. 11:54:13.806 [348.4724] <4> onlfi_thaw: do_thaw return value: 0 11:54:13.806 [348.4724] <4> onlfi_thaw: Thawing D:\ using snapshot method VSS. 11:54:15.806 [348.4724] <4> onlfi_thaw: do_thaw return value: 0 11:54:19.806 [348.4724] <2> fis_delete_id: removing D:\Program Files\Veritas\NetBackup\online_util\fi_cntl\bpfis.fim.htpststr001.san.mgmt.det_1248918143.0 11:54:19.806 [348.4724] <2> fis_delete_id: removing D:\Program Files\Veritas\NetBackup\online_util\fi_cntl\bpfis.fim.htpststr001.san.mgmt.det_1248918143.0.fiid 11:54:19.853 [348.4724] <4> bpfis: INF - EXIT STATUS 0: the requested operation was successfully completed The Question: Has anyone any experience of NetBackup / VSS not clearing snapshots after backups? We will ultimately be using a HP EVA for the snapshots, but we want to ensure correct functioning at a VSS level before we go further. Regards, Jonathan (PS: Question previously posted by my colleague on entsupport.symantec.com)

    Read the article

  • Moved DNS and Email Hosting, Now Can't Send/Receive To/From Domains Hosted on Previous Host

    - by maxfinis
    Our company had 4 domains whose emails and DNS were hosted by one company, and then we moved the email and DNS hosting for 3 of the 4 domains to a new company. Now, the 3 domains that were moved can't send or receive emails to and from the one domain still left on the old server. All other email functions work fine for all 4 domains. There are no bouncebacks, error messages, or emails stuck in queue, and no evidence of these missing emails hitting the new servers. The new hosting company confirms that everything is fine on their end, and assures me that it's most likely an old zone file still remaining on the old nameserver, and so the emails sent from the old host is routed to what it believes is still the authoritative nameserver. Because the old zone file's MX records still contain the old resource, the requests never leave the old nameserver to go online to do a fresh search for the real (new) authoritative nameserver. The compounding problem is that the old company is rather inept and doesn't seem to have the technical expertise to identify the problem, much less fix it. (I know, I know.) Is the problem truly that this old zone file just needs to be deleted from the old company's nameserver? If so, what's the best way for me to describe this to them? If not, what do you think could be the issue? Any help is much appreciated. I'm not in IT, so all this is new to me. I know it seems weird for me (the client) to have to do this legwork, but I just want to get this resolved. Here's what I've done: Ran dig to verify that the old server's MX records still point to the old authoritative server, instead of going online to do a fresh search: ~$ dig @old.nameserver.com domainthatwasmoved.com mx ; << DiG 9.6.0-APPLE-P2 << @old.nameserver.com domainThatWasMoved.com mx ; (1 server found) ;; global options: +cmd ;; Got answer: ;; -HEADER<<- opcode: QUERY, status: NOERROR, id: 61227 ;; flags: qr aa rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 0, ADDITIONAL: 1 ;; QUESTION SECTION: ;domainthatwasmoved.com. IN MX ;; ANSWER SECTION: domainthatwasmoved.com. 3600 IN MX 10 mail.oldmailserver.com. ;; ADDITIONAL SECTION: mail.oldmailserver.com. 3600 IN A 65.198.191.5 ;; Query time: 29 msec ;; SERVER: 65.198.191.5#53(65.198.191.5) ;; WHEN: Sun Dec 26 16:59:22 2010 ;; MSG SIZE rcvd: 88 Ran dig to try to see where the new hosting company's servers look when emails are sent from the 3 domains that were moved, and got refused: ~$ dig @new.nameserver.net domainStillAtOldHost.com mx ; << DiG 9.6.0-APPLE-P2 << @new.nameserver.net domainStillAtOldHost.com mx ; (1 server found) ;; global options: +cmd ;; Got answer: ;; -HEADER<<- opcode: QUERY, status: REFUSED, id: 31599 ;; flags: qr rd; QUERY: 1, ANSWER: 0, AUTHORITY: 0, ADDITIONAL: 0 ;; WARNING: recursion requested but not available ;; QUESTION SECTION: ;domainStillAtOldHost.com. IN MX ;; Query time: 31 msec ;; SERVER: 216.201.128.10#53(216.201.128.10) ;; WHEN: Sun Dec 26 17:00:14 2010 ;; MSG SIZE rcvd: 34

    Read the article

  • Having Hotlink Protectin problem in nginx

    - by Ayaz Malik
    Hello, i am having image hotlink protection problem in my nginx need help. i have a huge issue of my site's images being submited to social networks like stumbleupon with direct link ... xxxxx.jpg which some times get huge traffic and increases cpu usage plus bandwidth usage. what i am trying to do is block direct access to image from other refrers and hotlink protection. Here is the code from my vhost.conf server { access_log off; error_log logs/vhost-error_log warn; listen 80; server_name mydomain.com www.mydomain.com; # uncomment location below to make nginx serve static files instead of Apache # NOTE this will cause issues with bandwidth accounting as files wont be logged location ~* \.(gif|jpg|jpeg|png|wmv|avi|mpg|mpeg|mp4|htm|html|js|css)$ { root /home/username/public_html; expires 1d; } root /home/mydomain/public_html; } location / { client_max_body_size 10m; client_body_buffer_size 128k; proxy_send_timeout 90; proxy_read_timeout 90; proxy_buffer_size 4k; # you can increase proxy_buffers here to suppress "an upstream response # is buffered to a temporary file" warning proxy_buffers 16 32k; proxy_busy_buffers_size 64k; proxy_temp_file_write_size 64k; proxy_connect_timeout 30s; proxy_redirect http://www.mydomain.com:81 http://www.mydomain.com; proxy_redirect http://mydomain.com:81 http://mydomain.com; proxy_pass http://ip_address/; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; expires 24h; } } So for hotlink protection i added this code : location ~* (\.jpg|\.png|\.gif|\.jpeg)$ { valid_referers blocked www.mydomain.com mydomain.com; if ($invalid_referer) { return 403; } This is how the current nginx code for this domain looks like but didn't worked: server { access_log off; error_log logs/vhost-error_log warn; listen 80; server_name mydomain.com www.mydomain.com; # uncomment location below to make nginx serve static files instead of Apache # NOTE this will cause issues with bandwidth accounting as files wont be logged location ~* \.(gif|jpg|jpeg|png|wmv|avi|mpg|mpeg|mp4|htm|html|js|css)$ { root /home/username/public_html; expires 1d; } root /home/mydomain/public_html; } location ~* (\.jpg|\.png|\.gif|\.jpeg)$ { valid_referers blocked www.mydomain.com mydomain.com; if ($invalid_referer) { return 403; } location / { client_max_body_size 10m; client_body_buffer_size 128k; proxy_send_timeout 90; proxy_read_timeout 90; proxy_buffer_size 4k; # you can increase proxy_buffers here to suppress "an upstream response # is buffered to a temporary file" warning proxy_buffers 16 32k; proxy_busy_buffers_size 64k; proxy_temp_file_write_size 64k; proxy_connect_timeout 30s; proxy_redirect http://www.mydomain.com:81 http://www.mydomain.com; proxy_redirect http://mydomain.com:81 http://mydomain.com; proxy_pass http://ip_address/; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; expires 24h; } } Thank you in advance :) cheers

    Read the article

  • Reuse remote ssh connections and reduce command/session logging verbosity?

    - by ewwhite
    I have a number of systems that rely on application-level mirroring to a secondary server. The secondary server pulls data by means of a series of remote SSH commands executed on the primary. The application is a bit of a black box, and I may not be able to make modifications to the scripts that are used. My issue is that the logging in /var/log/secure is absolutely flooded with requests from the service user, admin. These commands occur many times per second and have a corresponding impact on logs. They rely on passphrase-less key exchange. The OS involved is EL5 and EL6. Example below. Is there any way to reduce the amount of logging from these actions. (By user? By source?) Is there a cleaner way for the developers to perform these ssh executions without spawning so many sessions? Seems inefficient. Can I reuse the existing connections? Example log output: Jul 24 19:08:54 Cantaloupe sshd[46367]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:54 Cantaloupe sshd[46446]: Accepted publickey for admin from 172.30.27.32 port 33526 ssh2 Jul 24 19:08:54 Cantaloupe sshd[46446]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:54 Cantaloupe sshd[46446]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:54 Cantaloupe sshd[46475]: Accepted publickey for admin from 172.30.27.32 port 33527 ssh2 Jul 24 19:08:54 Cantaloupe sshd[46475]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:54 Cantaloupe sshd[46475]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:54 Cantaloupe sshd[46504]: Accepted publickey for admin from 172.30.27.32 port 33528 ssh2 Jul 24 19:08:54 Cantaloupe sshd[46504]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:54 Cantaloupe sshd[46504]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:54 Cantaloupe sshd[46583]: Accepted publickey for admin from 172.30.27.32 port 33529 ssh2 Jul 24 19:08:54 Cantaloupe sshd[46583]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:54 Cantaloupe sshd[46583]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:54 Cantaloupe sshd[46612]: Accepted publickey for admin from 172.30.27.32 port 33530 ssh2 Jul 24 19:08:54 Cantaloupe sshd[46612]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:54 Cantaloupe sshd[46612]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:55 Cantaloupe sshd[46641]: Accepted publickey for admin from 172.30.27.32 port 33531 ssh2 Jul 24 19:08:55 Cantaloupe sshd[46641]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:55 Cantaloupe sshd[46641]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:55 Cantaloupe sshd[46720]: Accepted publickey for admin from 172.30.27.32 port 33532 ssh2 Jul 24 19:08:55 Cantaloupe sshd[46720]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:55 Cantaloupe sshd[46720]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:55 Cantaloupe sshd[46749]: Accepted publickey for admin from 172.30.27.32 port 33533 ssh2 Jul 24 19:08:55 Cantaloupe sshd[46749]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:55 Cantaloupe sshd[46749]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:55 Cantaloupe sshd[46778]: Accepted publickey for admin from 172.30.27.32 port 33534 ssh2 Jul 24 19:08:55 Cantaloupe sshd[46778]: pam_unix(sshd:session): session opened for user admin by (uid=0) Jul 24 19:08:55 Cantaloupe sshd[46778]: pam_unix(sshd:session): session closed for user admin Jul 24 19:08:55 Cantaloupe sshd[46857]: Accepted publickey for admin from 172.30.27.32 port 33535 ssh2

    Read the article

  • Trouble with site-to-site OpenVPN & pfSense not passing traffic

    - by JohnCC
    I'm trying to get an OpenVPN tunnel going on pfSense 1.2.3-RELEASE running on embedded routers. I have a local LAN 10.34.43.0/254. The remote LAN is 10.200.1.0/24. The local pfSense is configured as the client, and the remote is configured as the server. My OpenVPN tunnel is using the IP range 10.99.89.0/24 internally. There are also some additional LANs on the remote side routed through the tunnel, but the issue is not with those since my connectivity fails before that point in the chain. The tunnel comes up fine and the logs look healthy. What I find is this:- I can ping and telnet to the remote LAN and the additional remote LANs from the local pfSense box's shell. I cannot ping or telnet to any remote LANs from the local network. I cannot ping or telnet to the local network from the remote LAN or the remote pfSense box's shell. If I tcpdump the tun interfaces on both sides and ping from the local LAN, I see the packets hit the tunnel locally, but they do not appear on the remote side (nor do they appear on the remote LAN interface if I tcpdump that). If I tcpdump the tun interfaces on both sides and ping from the local pfSense shell, I see the packets hit the tunnel locally, and exit the remote side. I can also tcpdump the remote LAN interface and see them pass there too. If I tcpdump the tun interfaces on both sides and ping from the remote pfSense shell, I see the packets hit the remote tun but they do not emerge from the local one. Here is the config file the remote side is using:- #user nobody #group nobody daemon keepalive 10 60 ping-timer-rem persist-tun persist-key dev tun proto udp cipher BF-CBC up /etc/rc.filter_configure down /etc/rc.filter_configure server 10.99.89.0 255.255.255.0 client-config-dir /var/etc/openvpn_csc push "route 10.200.1.0 255.255.255.0" lport <port> route 10.34.43.0 255.255.255.0 ca /var/etc/openvpn_server0.ca cert /var/etc/openvpn_server0.cert key /var/etc/openvpn_server0.key dh /var/etc/openvpn_server0.dh comp-lzo push "route 205.217.5.128 255.255.255.224" push "route 205.217.5.64 255.255.255.224" push "route 165.193.147.128 255.255.255.224" push "route 165.193.147.32 255.255.255.240" push "route 192.168.1.16 255.255.255.240" push "route 192.168.2.16 255.255.255.240" Here is the local config:- writepid /var/run/openvpn_client0.pid #user nobody #group nobody daemon keepalive 10 60 ping-timer-rem persist-tun persist-key dev tun proto udp cipher BF-CBC up /etc/rc.filter_configure down /etc/rc.filter_configure remote <host> <port> client lport 1194 ifconfig 10.99.89.2 10.99.89.1 ca /var/etc/openvpn_client0.ca cert /var/etc/openvpn_client0.cert key /var/etc/openvpn_client0.key comp-lzo You can see the relevant parts of the routing tables extracted from pfSense here http://pastie.org/5365800 The local firewall permits all ICMP from the LAN, and my PC is allowed everything to anywhere. The remote firewall treats its LAN as trusted and permits all traffic on that interface. Can anyone suggest why this is not working, and what I could try next?

    Read the article

  • All PHP sites stopped working on IIS7, internal server error 500

    - by TimothyP
    I installed multiple drupal 7 sites using the Web Platform Installer on Windows Server 2008. Until know they worked without any problems, but recently internal server error 500 started to show up (once every so many requests), now it happens for all requests to any of the php sites. There's not much detail to go on, and nothing changed between the time when it was working and now (well nothing I know of anyway) The log file is flooded with messages such as [09-Aug-2011 09:08:04] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:16] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:16] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:20] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:22] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:51] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:09:56] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:09:57] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:12:13] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:15:09] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:15:09] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:21:28] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:21:28] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 I have tried increasing the memory limit in php.ini as such: memory_limit = 512MB But that doesn't seem to solve the problem either. This is in the global php configuration in IIS When I looked at the sites one by one, I noticed that PHP seemed to have been disabled. PHP is not enabled. Register new PHP version to enable PHP via FastCGI So I tried to register the php version again C:\Program Files\PHP\v5.3\php-cgi.exe But when I try to apply the changes I get There was an error while performing this operation Details: Operation is not valid due to the current state of the object There doesn't seem to be any other information than that. I have no idea why all of a sudden php isn't available for the sites anymore. PS: I have rebooted IIS, the server, etc... This server is hosted on amazon S3, so I gave the server some more power Update These seem to be two different issues I used memory_limit=128MB instead of memory_limit=128M Notice the "M" instead of "MB" A memory_limit of 128M was not enough, had to increase it to 512M The first issue caused internal server errors for every request. Increasing to 512MB seemed to have solved the problem for a little while, but after a while the server errors return. Note that the PHP manager inside of IIS still shows there is no PHP available for the sites (the global config does see it as available) So the problem remains unsolved

    Read the article

  • Bizarre and very specific Internet connection loss

    - by Synetech
    Yesterday (Friday, September 21, 2012), my Internet connection started acting up. After some testing, I confirmed a very specific and baffling set of symptoms: Internet connection goes away every 25-35 minutes (I did not confirm the exact interval, but it seems to be about 30 mins.) Only some protocols are affected; HTTP*, P2P, etc. stop working; FTP, etc. continue to work When it’s stopped, cannot even ping router or cable-modem IPs or view their firmware pages Domain-names and IPs are irrelevant (for protocols that stop working, neither work, for those that still work, both work) Resetting router fixes it for another 30 minutes Keeping the connection idle or active doesn’t seem to make a difference (nor the bandwidth usage in that period) Connecting directly to cable-modem allows it to work indefinitely Disconnecting the router from the cable-modem works indefinitely (no Internet connection obviously, but can still access router IP and firmware page) Connecting the router to the cable-modem, but putting the modem on standby also works indefinitely Same problem with both a wireless laptop and wired (on any port) desktop (both Windows 7; will try to test Windows XP when possible) Nothing had changed in the days leading up to the issue. No modifications to the networking configuration or the router; there were not even any Windows updates except for an MSSE definition update. Waiting does not fix it, nor does any amount of fiddling with anything; only resetting the router fixes it for 30 minutes (resetting the cable-modem doesn't work either) I tried cleaning the pins in the router’s plugs, but that didn’t help, which was not really a surprise since I was not getting a lost connection error. Obviously my first thought was that the router was having a problem, and this is borne out by some tests. The problem is that when it drops, it is not a full drop since I can still do things like ftp ftp.mcafee.com and such which means that the connection and DNS are still working. Moreover, if it were the router, then why does it stay alive indefinitely when not connected to the cable-modem (i.e., no outside influence)? The problem doesn't seem to be either the cable-modem nor the router, but rather an interaction between the two, like something from the outside (port scan? hacker? ISP?) that is triggering a problem in the router. I see that there have been a couple of vulnerabilities for the DI-524, but those were a while back and should be fixed since I have the last firmware for it. I don’t think it’s my ISP (Rogers) since I have been using the router for several years without problem and can connect indefinitely when bypassing it. But I can’t rule them out since that is one of the only possible things that could have suddenly changed. Does anybody have any ideas of explanations, fixed, or tests? (I note that when I opened the router, I heard a very high-pitched noise from somewhere near the capacitors/ferrite ring which I don’t think I heard the last time I opened it a few years ago, but then if it were that, then why would it affect only a very small, specific set of functions?)

    Read the article

  • How to troubleshoot problem with OpenVpn Appliance Server not able to connect

    - by Peter
    1) I have a Windows Server 2008 Standard SP2 2) I am running Hyper-V and have the OpenSvn Appliance Server virtual running 3) I have configured it as it said, only issue was that the legacy network adapter does not have a setting the instructions mention "Enable spoofing of MAC Addresses". My understand is that before R2, this was on by default. 4) Server is running, web interfaces look good 5) I am trying to connect from a Vista 64 box and cannot 5a) If I set to UPD I am stuck at Authorizing and client log looks like: 10/11/09 15:00:42: INFO: OvpnConfig: connect... 10/11/09 15:00:42: INFO: Gui listen socket at 34567 10/11/09 15:00:42: INFO: sending start command to instantiator... 10/11/09 15:00:42: INFO: start 34567 ?C:\Users\Peter\AppData\Roaming\OpenVPNTech\config?02369512D0C82A04B88093022DA0226202218022A902264022AE022B? 10/11/09 15:00:42: INFO: Got line from MI->>INFO:OpenVPN Management Interface Version 1 -- type 'help' for more info 10/11/09 15:00:42: INFO: Got line from MI->>HOLD:Waiting for hold release 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: real-time state notification set to ON 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: bytecount interval changed 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: hold flag set to OFF 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: hold release succeeded 10/11/09 15:00:43: INFO: Got line from MI->>PASSWORD:Need 'Auth' username/password 10/11/09 15:00:43: INFO: Processing PASSWORD. 10/11/09 15:00:43: INFO: OvpnClient: setting need auth to true. 10/11/09 15:00:43: INFO: OvpnConfig: Setting need auth to true. 10/11/09 15:00:43: INFO: Got auth request from active_config from 0 10/11/09 15:00:47: INFO: Sending Credentials.... 10/11/09 15:00:47: INFO: Sending 25 bytes for username. 10/11/09 15:00:47: INFO: Sent 25 bytes for username. 10/11/09 15:00:47: INFO: Sending 30 bytes for password. 10/11/09 15:00:47: INFO: Sent 30 bytes for password. 10/11/09 15:00:48: INFO: Got line from MI->SUCCESS: 'Auth' username entered, but not yet verified 10/11/09 15:00:48: INFO: Got line from MI->SUCCESS: 'Auth' password entered, but not yet verified 10/11/09 15:00:48: INFO: Got line from MI->>STATE:1255287647,WAIT,,, 10/11/09 15:00:48: INFO: Got line from MI->>BYTECOUNT:0,42 10/11/09 15:00:48: INFO: Got line from MI->>BYTECOUNT:54,42 10/11/09 15:00:48: INFO: Got line from MI->>STATE:1255287648,AUTH,,, 10/11/09 15:00:50: INFO: Got line from MI->>BYTECOUNT:2560,2868 10/11/09 15:00:52: INFO: Got line from MI->>BYTECOUNT:2560,3378 5b) I setup server for tcp and try to connect, I get a loop of authorizing and reconnecting. Log looks like: 10/11/09 15:00:42: INFO: Got line from MI->>HOLD:Waiting for hold release 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: real-time state notification set to ON 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: bytecount interval changed 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: hold flag set to OFF 10/11/09 15:00:43: INFO: Got line from MI->SUCCESS: hold release succeeded 10/11/09 15:00:43: INFO: Got line from MI->>PASSWORD:Need 'Auth' username/password 10/11/09 15:00:43: INFO: Processing PASSWORD. 10/11/09 15:00:43: INFO: OvpnClient: setting need auth to true. 10/11/09 15:00:43: INFO: OvpnConfig: Setting need auth to true. 10/11/09 15:00:43: INFO: Got auth request from active_config from 0 10/11/09 15:00:47: INFO: Sending Credentials.... 10/11/09 15:00:47: INFO: Sending 25 bytes for username. 10/11/09 15:00:47: INFO: Sent 25 bytes for username. 10/11/09 15:00:47: INFO: Sending 30 bytes for password. 10/11/09 15:00:47: INFO: Sent 30 bytes for password. 10/11/09 15:00:48: INFO: Got line from MI->SUCCESS: 'Auth' username entered, but not yet verified 10/11/09 15:00:48: INFO: Got line from MI->SUCCESS: 'Auth' password entered, but not yet verified 10/11/09 15:00:48: INFO: Got line from MI->>STATE:1255287647,WAIT,,, 10/11/09 15:00:48: INFO: Got line from MI->>BYTECOUNT:0,42 10/11/09 15:00:48: INFO: Got line from MI->>BYTECOUNT:54,42 10/11/09 15:00:48: INFO: Got line from MI->>STATE:1255287648,AUTH,,, 10/11/09 15:00:50: INFO: Got line from MI->>BYTECOUNT:2560,2868 10/11/09 15:00:52: INFO: Got line from MI->>BYTECOUNT:2560,3378 10/11/09 15:00:54: INFO: Got line from MI->>BYTECOUNT:2560,3888 ... Is there anyway to turn on robust logging on the server to understand what is happening? Any ideas on how to hunt this down?

    Read the article

  • SQLExpress service unable to start Error code 17053

    - by Chris Sobolewski
    A user was instructed by their software support to upgrade a program and install SQLExpress as part of the installation process. Since that time, the service has been able to start, citing error 17053, which appears to be an authentication issue. Here is the error log: 2011-01-11 13:17:45.50 Server Microsoft SQL Server 2005 - 9.00.3042.00 (Intel X86) Feb 9 2007 22:47:07 Copyright (c) 1988-2005 Microsoft Corporation Express Edition on Windows NT 5.1 (Build 2600: Service Pack 2) 2011-01-11 13:17:45.50 Server (c) 2005 Microsoft Corporation. 2011-01-11 13:17:45.50 Server All rights reserved. 2011-01-11 13:17:45.50 Server Server process ID is 3332. 2011-01-11 13:17:45.50 Server Authentication mode is WINDOWS-ONLY. 2011-01-11 13:17:45.50 Server Logging SQL Server messages in file 'c:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\LOG\ERRORLOG'. 2011-01-11 13:17:45.52 Server This instance of SQL Server last reported using a process ID of 2332 at 11/10/2010 2:15:24 PM (local) 11/10/2010 7:15:24 PM (UTC). This is an informational message only; no user action is required. 2011-01-11 13:17:45.52 Server Error: 17053, Severity: 16, State: 1. 2011-01-11 13:17:45.52 Server UpdateUptimeRegKey: Operating system error 5(Access is denied.) encountered. 2011-01-11 13:17:45.52 Server Registry startup parameters: 2011-01-11 13:17:45.52 Server -d c:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\DATA\master.mdf 2011-01-11 13:17:45.52 Server -e c:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\LOG\ERRORLOG 2011-01-11 13:17:45.52 Server -l c:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\DATA\mastlog.ldf 2011-01-11 13:17:45.52 Server Error: 17113, Severity: 16, State: 1. 2011-01-11 13:17:45.52 Server Error 3(The system cannot find the path specified.) occurred while opening file 'c:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\DATA\master.mdf' to obtain configuration information at startup. An invalid startup option might have caused the error. Verify your startup options, and correct or remove them if necessary. 2011-01-11 13:17:45.52 Server Error: 17053, Severity: 16, State: 1. 2011-01-11 13:17:45.52 Server UpdateUptimeRegKey: Operating system error 5(Access is denied.) encountered. 4 Server Error: 17053, Severity: 16, State: 1. 2011-01-11 13:08:21.34 Server UpdateUptimeRegKey: Operating system error 5(Access is denied.) encountered. 12:47:20.85 spid5s SQL Trace ID 1 was started by login "sa". 2011-01-11 12:47:20.90 spid5s Starting up database 'mssqlsystemresource'. 2011-01-11 12:47:20.93 spid5s The resource database build version is 9.00.3042. This is an informational message only. No user action is required. 2011-01-11 12:47:21.21 spid5s Error: 15466, Severity: 16, State: 1. 2011-01-11 12:47:21.21 spid5s An error occurred during decryption. 2011-01-11 12:47:21.38 spid8s Starting up database 'model'. 2011-01-11 12:47:21.38 Server Error: 17182, Severity: 16, State: 1. 2011-01-11 12:47:21.38 Server TDSSNIClient initialization failed with error 0x5, status code 0x90. 2011-01-11 12:47:21.38 Server Error: 17182, Severity: 16, State: 1. 2011-01-11 12:47:21.38 Server TDSSNIClient initialization failed with error 0x5, status code 0x1. 2011-01-11 12:47:21.38 Server Error: 17826, Severity: 18, State: 3. 2011-01-11 12:47:21.38 Server Could not start the network library because of an internal error in the network library. To determine the cause, review the errors immediately preceding this one in the error log. 2011-01-11 12:47:21.38 Server Error: 17120, Severity: 16, State: 1. 2011-01-11 12:47:21.38 Server SQL Server could not spawn FRunCM thread. Check the SQL Server error log and the Windows event logs for information about possible related problems. One lead I had was to change the SQL logon account from "Network Service" to "Local System". Unfortunately, that is resulting in the error message The Security ID Structure is Invalid [0x80070539] Any help either uninstalling or getting SQLExpress running would be fantastic.

    Read the article

  • Does this prove a network bandwidth bottleneck?

    - by Yuji Tomita
    I've incorrectly assumed that my internal AB testing means my server can handle 1k concurrency @3k hits per second. My theory at at the moment is that the network is the bottleneck. The server can't send enough data fast enough. External testing from blitz.io at 1k concurrency shows my hits/s capping off at 180, with pages taking longer and longer to respond as the server is only able to return 180 per second. I've served a blank file from nginx and benched it: it scales 1:1 with concurrency. Now to rule out IO / memcached bottlenecks (nginx normally pulls from memcached), I serve up a static version of the cached page from the filesystem. The results are very similar to my original test; I'm capped at around 180 RPS. Splitting the HTML page in half gives me double the RPS, so it's definitely limited by the size of the page. If I internally ApacheBench from the local server, I get consistent results of around 4k RPS on both the Full Page and the Half Page, at high transfer rates. Transfer rate: 62586.14 [Kbytes/sec] received If I AB from an external server, I get around 180RPS - same as the blitz.io results. How do I know it's not intentional throttling? If I benchmark from multiple external servers, all results become poor which leads me to believe the problem is in MY servers outbound traffic, not a download speed issue with my benchmarking servers / blitz.io. So I'm back to my conclusion that my server can't send data fast enough. Am I right? Are there other ways to interpret this data? Is the solution/optimization to set up multiple servers + load balancing that can each serve 180 hits per second? I'm quite new to server optimization, so I'd appreciate any confirmation interpreting this data. Outbound traffic Here's more information about the outbound bandwidth: The network graph shows a maximum output of 16 Mb/s: 16 megabits per second. Doesn't sound like much at all. Due to a suggestion about throttling, I looked into this and found that linode has a 50mbps cap (which I'm not even close to hitting, apparently). I had it raised to 100mbps. Since linode caps my traffic, and I'm not even hitting it, does this mean that my server should indeed be capable of outputting up to 100mbps but is limited by some other internal bottleneck? I just don't understand how networks at this large of a scale work; can they literally send data as fast as they can read from the HDD? Is the network pipe that big? In conclusion 1: Based on the above, I'm thinking I can definitely raise my 180RPS by adding an nginx load balancer on top of a multi nginx server setup at exactly 180RPS per server behind the LB. 2: If linode has a 50/100mbit limit that I'm not hitting at all, there must be something I can do to hit that limit with my single server setup. If I can read / transmit data fast enough locally, and linode even bothers to have a 50mbit/100mbit cap, there must be an internal bottleneck that's not allowing me to hit those caps that I'm not sure how to detect. Correct? I realize the question is huge and vague now, but I'm not sure how to condense it. Any input is appreciated on any conclusion I've made.

    Read the article

  • Windows Server 2012 Migration (DNS/AD DS Standard Eval to Essentials OEM) P2V -> Do I need a Secondary Domain Controller during migration?

    - by Aubrey Robertson
    This is my first post on this exchange (although not my first on stack exchange), so please have patience. I am a 3rd year student intern, and I have been tasked with virtualizing the server systems at the company I work for. I have come a long way, and I am almost ready to install the VM Server in migration mode. Here is some information: Source Server: Windows Server 2012 Standard Evaluation DNS Server (local only) Advanced Directory Domain Services File and Storage stuff A few other server roles Destination Server: Windows Server 2012 Essentials OEM (Hyper-V client) Running under a temporary Hyper-V host (will migrate the Hyper-V host back to the old machine after the original server is virtualized as a client). Sitting currently at the "Select Installation Mode" screen. I have been following the guides on Microsoft tech net, and today I spent most of the day getting rid of issues in the Best Practices Analyser on the source machine. I have 3 remaining issues (which are all related): ERROR: DNS: DNS servers on Ethernet (adapter name) should include the loopback address, but not as the first entry (flavour text indicates that, during migration, the DNS server may not be found) WARNING: All domains should have at least two domain controllers for redundancy. WARNING: DNS: Ethernet should be configured to use both a preferred and an alternate DNS Server. All of these issues can be resolved by deploying a secondary domain controller, but I have never done that before (see my concerns below). The main issue here that I am concerned with for installing in migration mode is the FIRST one (the error). If I try and set-up the new server deployment, and the adapter domain controller is listed as localhost, then this may cause the installation to fail. (at least, this is what the Microsoft documentation suggests). But I do not have another IP address to enter here as I have no other local domain controllers. So I did the first obvious thing that came to my mind, and tried to use Google DNS servers as my alternates. That did not work because they couldn't recognize other computers in the "forest". Now I'm no expert when it comes to DNS, so please forgive my ignorance. This DNS server is concerned only with Active Directory stuffs for the local network. If I go ahead with migration, and it fails, then I will just have to go ahead and install a secondary DNS server I suppose. The problem I have here is that I am limited by the amount of Windows Server keys I have available (I have 2); however, I do have access to a Linux box running Debian Wheezy that I set-up two weeks ago as a Mantis server. I could install Windows Server 2012 as a secondary DNS (I think) in a VM and use that, but then it seems like I will be wasting time, and probably the Windows key too, and if there's another way to do it with Linux that would be much better. Even better still, do I even need a secondary DNS server for migration at all? The hints said that during migration the original machine "might" not be found. Thank you for your time and consideration.

    Read the article

  • Add a small RAID card? Will it help overall stability and performance of my nine hard drives?

    - by Ray
    Hi, Will I get any extra genuine added performance and RAID stability if I insert a basic RAID card into a PCI-E x1 slot? I am considering the Adaptec 1220SA - 2 port SATA , pci-express (1x) , raid 0/1. Ok it only supports two SATA drives. Purpose is to help support the eight internal hard drives (1TB each), a DVD drive and an external e-SATA connected 2TB hard drive - by dealing with two of the internal hard drives. My current configuration of eight internal 1TB Barracuda (7200.12) SATA hard drives, one external 2TB SATA Western Digital Green Drive (e-SATA) and one DVD drive can already be supported by the Intel P55 & JMicron controllers on the ASUS motherboard : the Intel P55 (controls six HDD; configured as three x RAID 1), and the JMicron (controls two HDD as one RAID 1, as well as the DVD drive and the external SATA drive via the motherboard's e-SATA port (controlled by the JMicron)). Bigger picture details : I have an ASUS motherboard designed for the LGA1156 type processor and it includes the Intel P55 Express Chipset and JMicron. I am using the Intel Core i7-870 processor, and have 8GB DDR3 (1333) memory (four x 2GB Corsair DIMMs). Enough overall power. The power supply is more than sufficicient for the system. Corsair AX850. The system will never need the full 850 watts (future : second graphics card). The RAID card would provide hardware RAID 1 for two of the eight intrnal drives. It would either reduce the load on : the Intel P55 firmware RAID support, or replace the JMicron controller's RAID 1 set. I am busy installing the above configuration using Windows 7 Ultimate 64-bit as the OS. The RAID card is a last minute addition to the plan. Is it worth spending the extra R700 - R900 on the Adaptec 1220SA, or equivalent RAID card? I cannot afford to spend yet another R2000 - R3000 on a RAID card that would support many SATA2 hard drives, with a better RAID, example the RAID 5. My Issue & assumption : I am trusting that the Intel P55 chipset can properly handle six drives, configured as three * RAID 1. I am assuming that the JMicron can handle, using its RED SATA ports, one RAID-1 (two HDDs). The DVD drive connects to the JMicron optical SATA port 1 (white port 1). White port 2 is not used. The e-SATA connection is from the JMicron straight to, and through the motherboard - to an on-board (rear panel) e-SATA port. Am I being a little hopeful in only using the on-board Intel P55 and the JMicron? Is it a waste of money to install a RAID card that handles two SATA2 drives? OR Is it wisdom to take the pressure a little off the Intel P55? Obviously I am interested in data security, hence RAID 1, not RAID Zero. RAID 5 would be nice. The CPU, Intel Core i7-870 will provide the clout. Context to nine drives : I am using virtualisation with Windows 7 Ultimate. Bootable VMs. The operating system gets a mirror. Loaded apps gets a mirror. The current design data is kept in another mirror and Another mirror is back-up one and / or VM territory. Then the external 2TB drive (via e-SATA) is the next layer of data security and then finally, I use off-site data security. Thanks.

    Read the article

  • Windows 7 / Ubuntu Dualboot GRUB Problem.

    - by Tek
    I'd like to first say ahead of time that I'm running a RAID-0 Setup. 1.First of all, I'm glad Ubuntu 9.10 installed flawlessly and detected my RAID-0 setup just fine. The issue I'm having now is that I already had Windows 7 installed and made a small 12GB partition for Linux/Swap. I grabbed EasyBCD 2.0 to edit the W7 bootloader and configured it to use dual boot Grub2 because before it didn't even show the option for Ubuntu. The bootloader points to a file made in the windows directory made by EasyBCD called "C:\NST\AutoNeoGrub0.mbr" which is what I'm guessing grub is booting from. After that I got the option for booting Ubuntu. The problem is that it's sending me to the Grub prompt (probably because it's pointing to \NST|AutoNeoGrub0.mbr?), at first I didn't know what to do but I researched and have to type grub commands to manually boot into Ubuntu Linux. Ex: grubroot (hd0,4) grubkernel /boot/vmlinuz-2.6... root=/dev/disk/by-uuid/24624-2424... grubinitrd boot/initrd.img-2.6... grubboot After all that Ubuntu boots just fine, but how do I fix it permanently? Do I need to edit the bootloader manually (since Easy BCD "autoconfigures")? Some insight on this would rock! Also, it sucks to type the actual uuid since it's REALLY long. I tried getting the name of the drive via fdisk -l but since it's raid 0 I'm guessing I can't do that. How can I get a shorter name of the drive? like /dev/sda, /dev/sdb etc? I've also tried to update to the latest GRUB and I got this: Creating config file /etc/default/grub with new version Generating core.img error: cannot seek /dev/sdc' error: cannot seek/dev/sdc' grub-probe: error: no mapping exists for nvidia_dbedfcca5' Auto-detection of a filesystem module failed. Please specify the module with the option--modules' explicitly. dpkg: error processing grub-pc (--configure): subprocess installed post-installation script returned error exit status 1 dpkg: dependency problems prevent configuration of grub2: grub2 depends on grub-pc; however: Package grub-pc is not configured yet. dpkg: error processing grub2 (--configure): dependency problems - leaving unconfigured No apport report written because the error message indicates its a followup error from a previous failure. E: Sub-process /usr/bin/dpkg returned an error code (1) I've also tried: b@dnb:~$ sudo update-grub error: cannot seek /dev/sdc' error: cannot seek/dev/sdc' Generating grub.cfg ... Found linux image: /boot/vmlinuz-2.6.31-14-generic Found initrd image: /boot/initrd.img-2.6.31-14-generic error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca5' error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca5' Found memtest86+ image: /boot/memtest86+.bin Found Windows 7 (loader) on /dev/mapper/nvidia_dbedfcca1 error: cannot seek /dev/sdc' grub-probe: error: no mapping exists fornvidia_dbedfcca1' done To no avail. Any idea what I can do to fix this mess? :( Edit: This is my disk configuration. b@dnb:~$ sudo df -l Filesystem 1K-blocks Used Available Use% Mounted on /dev/mapper/nvidia_dbedfcca5 12302232 2744788 8932520 24% / udev 1030288 268 1030020 1% /dev none 1030288 964 1029324 1% /dev/shm none 1030288 92 1030196 1% /var/run none 1030288 0 1030288 0% /var/lock none 1030288 0 1030288 0% /lib/init/rw /dev/sr0 706532 706532 0 100% /media/cdrom0 Note: /dev/mapper/nvidia_dbedfcca5 is my Linux boot partition

    Read the article

  • IBM Server Config questions

    - by Joel Coel
    I have a few questions on a potential server setup. First, the situation: Last year we bought an IBM x3500 server with 2 Xeon E5410's, 9GB RAM, 6 HDDs. The original intent for this server was to replace the old exchange e-mail server. It was brought in, set up, and then shortly after we switched to gmail. Shortly after that my predecessor left for greener pastures, and finally I was hired. So this nice server is now sitting (mostly) idle. This year I have budget again for one server, and of course I want to put this other server to work. I'm thinking about the best use for the two server, and I think I finally have a plan for what I want to do with them. The idea is to use the two newer servers as a pair of VM hosts. I will set up each server with the same 8 VMs, but divide up the load so that only 4 are active per physical host. That means I've normally got 2GB RAM + 2 cores per host. I've done some load testing to pick out what servers to convert to virtual, and chose them so that each host will be capable of handling the entire set of 8 by itself in a pinch with 1 core and 1GB RAM, but would be very taxed to do so. This should take our data center from 13 total servers down to 7. The "servers" I'm replacing are mostly re-purposed desktops, so I'm more than happy to be able to do this. Now it's time to go shopping for the new server. I'd like my two hosts to match as closely as possible, and so I'm looking at IBM again. It also helps that we have some educational matching grant money from IBM that I need to use to help pay for this system (we're a small private college). So finally, (if you're not bored already), we come to my questions: Am I missing anything big or obvious in this plan? I'm a little worried about network performance since the VM hosts will only have 4 nics total where 8 used to be, but I don't think it will be a problem. Is there anything else like this I might be overlooking? Am I making it even too complicated? IBM no longer has a good analog to last year's server. If I want to match the performance (8 cores, 9GB RAM, 1333mhz front side bus, 6 spindles), I have to spend quite a bit more than we paid last year: $2K+, or nearly a 33% cost increase. This only brings a marginal increase in performance. The alternative to stay in budget is to take a hit on the fsb down to 800mhz or cut the number of cores in half, neither of which is attractive. The main cost culprit is the processor. IBM no longer offers the E5410. It's listed as a part, but not available in any of the server configs I've looked at. I'm considering getting the cheapest 800mhz fsb dual core xeon I can configure and then buying the E5410's separately. That's still an extra $350 I wasn't counting on, but that's better than $2K. I want to know what others think of this - will it work or will I end up with the wrong motherboard or some other issue? Am I missing a simple way to configure the server I really want? I don't really intend to do this, but one option to save some money back is to omit the redundant power supply. Since my redundancy plan for these system is to switch over to a completely different host, the extra power isn't fully necessary. That said, it's still very helpful to avoid even short downtimes while I switch over VMs. Has anyone done this?

    Read the article

  • Installing Mod-wsgi 3.3 for apache 2.2 and python 3.2

    - by aaronasterling
    I am attempting to install Mod-wsgi 3.3 on an ubuntu 11.10 desktop edition with apache 2.2 and python 3.2 I downloaded the source tarball and extracted it. I configured it using the --with-python=/usr/bin/python3 option to configure. This is the only copy of python3 that I have installed. I then issued the commands make and sudo make install. I attempted to restart apache using sudo /etc/init.d/apache2 restart and get the following error message: apache2: Syntax error on line 203 of /etc/apache2/apache2.conf: Syntax error on line 1 of /etc/apache2/mods-enabled/wsgi.load: Cannot load /usr/lib/apache2/modules /mod_wsgi.so into server: /usr/lib/apache2/modules/mod_wsgi.so: undefined symbol: PyCObject_FromVoidPtr Action 'configtest' failed. The Apache error log may have more information. ...fail! The error logs only inform us that it's a segfault: ` I checked to make sure that it's linked against the right python library with ldd mod_wsgi.so and got the output linux-gate.so.1 => (0x00d66000) libpython3.2mu.so.1.0 => /usr/lib/libpython3.2mu.so.1.0 (0x0065b000) libpthread.so.0 => /lib/i386-linux-gnu/libpthread.so.0 (0x00a20000) libc.so.6 => /lib/i386-linux-gnu/libc.so.6 (0x00110000) libssl.so.1.0.0 => /lib/i386-linux-gnu/libssl.so.1.0.0 (0x0028c000) libcrypto.so.1.0.0 => /lib/i386-linux-gnu/libcrypto.so.1.0.0 (0x0044c000) libffi.so.6 => /usr/lib/i386-linux-gnu/libffi.so.6 (0x002d9000) libz.so.1 => /lib/i386-linux-gnu/libz.so.1 (0x00eb3000) libexpat.so.1 => /lib/i386-linux-gnu/libexpat.so.1 (0x00abe000) libdl.so.2 => /lib/i386-linux-gnu/libdl.so.2 (0x002e0000) libutil.so.1 => /lib/i386-linux-gnu/libutil.so.1 (0x00c47000) libm.so.6 => /lib/i386-linux-gnu/libm.so.6 (0x00e24000) /lib/ld-linux.so.2 (0x0042c000) It seems to be linking against the python3 library so I'm not sure what the issue is. I have read on another question that mod-python can present problems however it was never installed. I saw that the directive WSGIPythonHome can be used to point to the correct python version and created a directory /usr/bin/apache2-python/ with a link named python and python3(the name I passed to the configure script) to /usr/bin/python3 This results in the same error. So I'm pretty sure it's using the correct version of python. I am now at a loss. Thanks in advance for any help. update Using the version from the repository I get the following log when I attempt to request a page: [Wed Mar 21 13:21:11 2012] [notice] child pid 5567 exit signal Aborted (6) Fatal Python error: Py_Initialize: Unable to get the locale encoding LookupError: no codec search functions registered: can't find encoding [Wed Mar 21 13:21:13 2012] [notice] child pid 5568 exit signal Aborted (6) Fatal Python error: Py_Initialize: Unable to get the locale encoding LookupError: no codec search functions registered: can't find encoding [Wed Mar 21 13:21:14 2012] [notice] caught SIGTERM, shutting down If I comment out the instruction to load mod-wsgi, the page serves normally.

    Read the article

  • BluRay audio/video stuttering with PowerDVD 11, WinDVD 11 Pro, etc? Xonar/Auzen HD audio option?

    - by jrista
    I recently upgraded my Windows 7 MediaCenter HTPC due to a motherboard failure (really old motherboard and cpu, it was on its last legs.) I chose to upgrade to an i5 system with everything built into the motherboard. I did my due diligence, researched, and found some hardware that was within my budget. I ended up with: Core i5 2500K (3.3Ghz) Corsair XMS3 2x2Gb DDR3 (4Gb) ASUS P8H 61-M LE/CSM MicroCenter 64Gb SSD (Previous BluRay player, forget the brand) The system is pretty awesome, and plays everything I have perfectly. I almost went with an Atom solution, however there have been numerous notes that they do not play NetFlix Instant Watch well...and I am a heavy Netflix IW user. High definition BluRay rips work well, although they usually contain lower audio quality than the BluRay's they were ripped from. The real problem I am encountering is playing back BluRay video from discs. For some reason, I am encountering rather terrible stuttering problems with both the audio and video. The stuttering is synchronous in both, and occurs at seemingly random intervals. I've used PowerDVD 9, PowerDVD 11 trial, and WinDVD 11 Pro trial. All three have stuttering problems, although PowerDVD 11 seems to have the least. Watching system resource usage, CPU load is never above 20%, and memory usage tends to be a constant 1/3rd the total available system memory. When playback is fine, its superb...the video is crystal clear. The audio quality is ok, certainly not what I would expect from a BluRay disc. I did some research, and it seems that playing BluRay from a PC causes a downsampling of the audio? I am curious if the audio is my primary problem here, the cause of the stuttering I am encountering? When stuttering occurs, the audio gets REALLY bad, while the video just pauses momentarily every second until for whatever reason everything picks up and runs fine (usually after a few seconds to a couple minutes.) The audio chipset is a Realtek HD ALC887 8-channel, supposedly designed to support BluRay playback. Has anyone encountered any issues like this playing back bluray discs on a PC (namely with PowerDVD...WinDVD was FAR worse, and seemed to have real trouble even reading the discs, and I have no interest in fiddling with it further.) Is there any reason to suspect the video decoding as the problem?(Given how bad the audio gets during a stutter, and how clean the video remains, I am inclined to think the issue boils down to audio.) Is it even remotely possible that the motherboard, cpu, or ram are causing the stuttering (all three are pretty blazing fast...faster than the hardware that I replaced, which seemed to play BluRay fine with PowerDVD 9.) I've read a bit about the Asus Xonar HDAV 1.3 and the Auzen X-Fi HomeTheater HD home theater hi-fi audio cards. Seems they are the only way to get true full-quality, uncompressed BluRay audio bitstreaming over HDMI on a PC. None of the usual suspects seem to have these cards in stock, however. Are these cards worth getting? Are they even still available, or have they been discontinued (if so, that would indeed be sad...they sound simply fantastic.)

    Read the article

  • FreeBSD with Vagrant - don't know how to check guest additions version

    - by joelmaranhao
    On Mac OS X 10.9.3 Picked a box from the VagrantCloud Init the vagrant box $ vagrant init chef/freebsd-9.2-i386 A `Vagrantfile` has been placed in this directory. You are now ready to `vagrant up` your first virtual environment! Please read the comments in the Vagrantfile as well as documentation on `vagrantup.com` for more information on using Vagrant. List the files $ ls -al -rw-r--r-- 1 joel staff 4831 Jun 5 17:17 Vagrantfile Vagrantfile content VAGRANTFILE_API_VERSION = "2" Vagrant.configure(VAGRANTFILE_API_VERSION) do |config| config.vm.box = "chef/freebsd-9.2-i386" end Starting my virtual box leads to Errors $ vagrant up Bringing machine 'default' up with 'virtualbox' provider... ==> default: Box 'chef/freebsd-9.2-i386' could not be found. Attempting to find and install... default: Box Provider: virtualbox default: Box Version: >= 0 ==> default: Loading metadata for box 'chef/freebsd-9.2-i386' default: URL: https://vagrantcloud.com/chef/freebsd-9.2-i386 ==> default: Adding box 'chef/freebsd-9.2-i386' (v1.0.0) for provider: virtualbox default: Downloading: https://vagrantcloud.com/chef/freebsd-9.2-i386/version/1/provider/virtualbox.box ==> default: Successfully added box 'chef/freebsd-9.2-i386' (v1.0.0) for 'virtualbox'! ==> default: Importing base box 'chef/freebsd-9.2-i386'... ==> default: Matching MAC address for NAT networking... ==> default: Checking if box 'chef/freebsd-9.2-i386' is up to date... ==> default: Setting the name of the VM: freebsd92-i386_default_1401982167145_49633 ==> default: Fixed port collision for 22 => 2222. Now on port 2201. ==> default: Clearing any previously set network interfaces... ==> default: Preparing network interfaces based on configuration... default: Adapter 1: nat ==> default: Forwarding ports... default: 22 => 2201 (adapter 1) ==> default: Booting VM... ==> default: Waiting for machine to boot. This may take a few minutes... default: SSH address: 127.0.0.1:2201 default: SSH username: vagrant default: SSH auth method: private key default: Warning: Connection timeout. Retrying... default: Warning: Connection timeout. Retrying... ==> default: Machine booted and ready! Sorry, don't know how to check guest version of Virtualbox Guest Additions on this platform. Stopping installation. ==> default: Checking for guest additions in VM... default: The guest additions on this VM do not match the installed version of default: VirtualBox! In most cases this is fine, but in rare cases it can default: prevent things such as shared folders from working properly. If you see default: shared folder errors, please make sure the guest additions within the default: virtual machine match the version of VirtualBox you have installed on default: your host and reload your VM. default: default: Guest Additions Version: 4.2.16 default: VirtualBox Version: 4.3 ==> default: Mounting shared folders... default: /vagrant => /Users/joel/Code/anybots/operations/robot/freebsd92-i386 Vagrant attempted to execute the capability 'mount_virtualbox_shared_folder' on the detect guest OS 'freebsd', but the guest doesn't support that capability. This capability is required for your configuration of Vagrant. Please either reconfigure Vagrant to avoid this capability or fix the issue by creating the capability. Note that I have recently installed the latest version of VirtualBox, but somehow I can't find the Guest Additions.

    Read the article

  • can't login to new install of SQL 2008 x64 via SSMS

    - by tpcolson
    I have performed a fresh install of SQL 2008 x64 on a fresh install of Server 2008 R2 x64 in an AD environment. Upon install completion, I cannot login to the SQL Instance via SSMS, with the following error: Login failed for user domain\user. Reason: Token-based server access validation failed with an infrastructure error. Check for previous errors. [CLIENT: ]. Background: the server is correctly joined to the AD Domain, the install was performed with defaults, windows authentication only (per organizational rules), the SQL install completes with no errors, domain\user was added as SQL Amin during setup account provisioning, I am logged into to console as domain\user when this error occurs, windows firewall is OFF, UAC is ON (an will never be turned off in accordance with organizational policy). To troubleshoot this error I have tried: Run SSMS as administrator: fail; Start SQL in single user mode, run SSMS: fail Start SQL in single user mode, run SSMS as administrator: Success Start SQL in single user mode, run SSMS as administrator, remove domain\user from sysadmin group, re-add, run SSMS: fail; Any combination and permutation of log off and log on, reboot, and chant gregorian prayers: fail; Reimage server with 2008 x64, slipstream SP2 into SQL 2008 install, all above troubleshooting steps are repeatable exactly, so I've narrowed this down to not being a SP issue; (this is NOT 2008 SQL R2) Any suggestion on how to grant management access to this fresh install of SQL 2008 via SSMS? Our organizational policy is no console access to servers, management will be done via management tools intalled on client workstations. domain\user is a group of 8 users whom will have SSMS installed on workstations. However, we can't even access SQL via SSMS from the console! We cannot deploy this in an environment where these 8 users will have to sneak into the server closet on the weekends and have console access to SQL and run SSMS as administrator. EDIT: domain\group is a replacement for the actual object; the queries indicate that domain\group does indeed have the right privelges....!?! 1> EXEC xp_logininfo 'domain\group' go account name type privilege mapped login name permission path 'domain\group' group admin 'domain\group' NULL xp_logininfo seems to show 'domain\group' in the sql admin group; 1> SELECT A.name AS 'Role', B.name AS 'Login' 3> FROM sys.server_role_members C 5> INNER JOIN sys.server_principals A ON A.principal_id = C.role_principal_id 7> INNER JOIN sys.server_principals B ON B.principal_id = C.member_principal _id 9> go Role Login sysadmin sa sysadmin NT AUTHORITY\SYSTEM sysadmin NT SERVICE\MSSQLSERVER sysadmin NT SERVICE\SQLSERVERAGENT sysadmin domain\group 1> SELECT PRINCIPAL_ID AS [Principal ID], 2> NAME AS [User], 3> TYPE_DESC AS [Type Description], 4> IS_DISABLED AS [Status] 5> FROM sys.server_principals 6> GO Principal ID User Type Description Status ------------ ------------------------------------------------------------------- ------------------------------------------------------------- ------------------ ------------------------------------------ ------ 1 sa SQL_LOGIN 1 2 public SERVER_ROLE 0 3 sysadmin SERVER_ROLE 0 4 securityadmin SERVER_ROLE 0 5 serveradmin SERVER_ROLE 0 6 setupadmin SERVER_ROLE 0 7 processadmin SERVER_ROLE 0 8 diskadmin SERVER_ROLE 0 9 dbcreator SERVER_ROLE 0 10 bulkadmin SERVER_ROLE 0 101 ##MS_SQLResourceSigningCertificate## CERTIFICATE_MAPPED _LOGIN 0 102 ##MS_SQLReplicationSigningCertificate## CERTIFICATE_MAPPED _LOGIN 0 103 ##MS_SQLAuthenticatorCertificate## CERTIFICATE_MAPPED _LOGIN 0 105 ##MS_PolicySigningCertificate## CERTIFICATE_MAPPED _LOGIN 0 257 ##MS_PolicyTsqlExecutionLogin## SQL_LOGIN 1 259 NT AUTHORITY\SYSTEM WINDOWS_LOGIN 0 260 NT SERVICE\MSSQLSERVER WINDOWS_GROUP 0 262 NT SERVICE\SQLSERVERAGENT WINDOWS_GROUP 0 263 ##MS_PolicyEventProcessingLogin## SQL_LOGIN 1 264 ##MS_AgentSigningCertificate## CERTIFICATE_MAPPED _LOGIN 0 265 domain\group WINDOWS_GROUP 0 (21 rows affected)

    Read the article

  • How to troubleshoot a PHP script that causes a Segmenation Fault?

    - by johnlai2004
    I posted this on stackoverflow.com as well because I'm not sure if this is a programming problem or a server problem. I'm using ubuntu 9.10, apache2, mysql5 and php5. I've noticed an unusual problem with some of my php programs. Sometimes when visiting a page like profile.edit.php, the browser throws a dialogue box asking to download profile.edit.php page. When I download it, there's nothing in the file. profile.edit.php is supposed to be a web form that edits user information. I've noticed this on some of my other php pages as well. I look in my apache error logs, and I see a segmentation fault message: [Mon Mar 08 15:40:10 2010] [notice] child pid 480 exit signal Segmentation fault (11) And also, the issue may or may not appear depending on which server I deploy my application too. Additonal Details This doesn't happen all the time though. It only happens sometimes. For example, profile.edit.php will load properly. But as soon as I hit the save button (form action="profile.edit.php?save=true"), then the page asks me to download profile.edit.php. Could it be that sometimes my php scripts consume too much resources? Sample code Upon save action, my profile.edit.php includes a data_access_object.php file. I traced the code in data_access_object.php to this line here if($params[$this->primaryKey]) { $q = "UPDATE $this->tableName SET ".implode(', ', $fields)." WHERE ".$this->primaryKey." = ?$this->primaryKey"; $this->bind($this->primaryKey, $params[$this->primaryKey], $this->tblFields[$this->primaryKey]['mysqlitype']); } else { $q = "INSERT $this->tableName SET ".implode(', ', $fields); } // Code executes perfectly up to this point // echo 'print this'; exit; // if i uncomment this line, profile.edit.php will actually show 'print this'. If I leave it commented, the browser will ask me to download profile.edit.php if(!$this->execute($q)){ $this->errorSave = -3; return false;} // When I jumped into the function execute(), every line executed as expected, right up to the return statement. And if it helps, here's the function execute($sql) in data_access_object.php function execute($sql) { // find all list types and explode them // eg. turn ?listId into ?listId0,?listId1,?listId2 $arrListParam = array_bubble_up('arrayName', $this->arrBind); foreach($arrListParam as $listName) if($listName) { $explodeParam = array(); $arrList = $this->arrBind[$listName]['value']; foreach($arrList as $key=>$val) { $newParamName = $listName.$key; $this->bind($newParamName,$val,$this->arrBind[$listName]['type']); $explodeParam[] = '?'.$newParamName; } $sql = str_replace("?$listName", implode(',',$explodeParam), $sql); } // replace all ?varName with ? for syntax compliance $sqlParsed = preg_replace('/\?[\w\d_\.]+/', '?', $sql); $this->stmt->prepare($sqlParsed); // grab all the parameters from the sql to create bind conditions preg_match_all('/\?[\w\d_\.]+/', $sql, $matches); $matches = $matches[0]; // store bind conditions $types = ''; $params = array(); foreach($matches as $paramName) { $types .= $this->arrBind[str_replace('?', '', $paramName)]['type']; $params[] = $this->arrBind[str_replace('?', '', $paramName)]['value']; } $input = array('types'=>$types) + $params; // bind it if(!empty($types)) call_user_func_array(array($this->stmt, 'bind_param'), $input); $stat = $this->stmt->execute(); if($GLOBALS['DEBUG_SQL']) echo '<p style="font-weight:bold;">SQL error after execution:</p> ' . $this->stmt->error.'<p>&nbsp;</p>'; $this->arrBind = array(); return $stat; }

    Read the article

  • php-fpm + persistent sockets = 502 bad gateway

    - by leeoniya
    Put on your reading glasses - this will be a long-ish one. First, what I'm doing. I'm building a web-app interface for some particularly slow tcp devices. Opening a socket to them takes 200ms and an fwrite/fread cycle takes another 300ms. To reduce the need for both of these actions on each request, I'm opening a persistent tcp socket which reduces the response time by the aforementioned 200ms. I was hoping PHP-FPM would share the persistent connections between requests from different clients (and indeed it does!), but there are some issues which I havent been able to resolve after 2 days of interneting, reading logs and modifying settings. I have somewhat narrowed it down though. Setup: Ubuntu 13.04 x64 Server (fully updated) on Linode PHP 5.5.0-6~raring+1 (fpm-fcgi) nginx/1.5.2 Relevent config: nginx worker_processes 4; php-fpm/pool.d pm = dynamic pm.max_children = 2 pm.start_servers = 2 pm.min_spare_servers = 2 Let's go from coarse to fine detail of what happens. After a fresh start I have 4x nginx processes and 2x php5-fpm processes waiting to handle requests. Then I send requests every couple seconds to the script. The first take a while to open the socket connection and returns with the data in about 500ms, the second returns data in 300ms (yay it's re-using the socket), the third also succeeds in about 300ms, the fourth request = 502 Bad Gateway, same with the 5th. Sixth request once again returns data, except now it took 500ms again. The process repeats for several cycles after which every 4 requests result in 2x 502 Bad Gateways and 2x 500ms Data responses. If I double all the fpm pool values and have 4x php-fpm processes running, the cycles settles in with 4x successful 500ms responses followed by 4x Bad Gateway errors. If I don't use persistent sockets, this issue goes away but then every request is 500ms. What I suspect is happening is the persistent socket keeps each php-fpm process from idling and ties it up, so the next one gets chosen until none are left and as they error out, maybe they are restarted and become available on the next round-robin loop ut the socket dies with the process. I haven't yet checked the 'slowlog', but the nginx error log shows lots of this: *188 recv() failed (104: Connection reset by peer) while reading response header from upstream, client:... All the suggestions on the internet regarding fixing nginx/php-fpm/502 bad gateway relate to high load or fcgi_pass misconfiguration. This is not the case here. Increasing buffers/sizes, changing timeouts, switching from unix socket to tcp socket for fcgi_pass, upping connection limits on the system....none of this stuff applies here. I've had some other success with setting pm = ondemand rather than dynamic, but as soon as the initial fpm-process gets killed off after idling, the persistent socket is gone for all subsequent php-fpm spawns. For the php script, I'm using stream_socket_client() with a STREAM_CLIENT_PERSISTENT flag. A while/stream_select() loop to detect socket data and fread($sock, 4096) to grab the data. I don't call fclose() obviously. If anyone has some additional questions or advice on how to get a persistent socket without tying up the php-fpm processes beyond the request completion, or maybe some other things to try, I'd appreciate it. some useful links: Nginx + php-fpm - recv() error Nginx + php-fpm "504 Gateway Time-out" error with almost zero load (on a test-server) Nginx + PHP-FPM "error 104 Connection reset by peer" causes occasional duplicate posts http://www.linuxquestions.org/questions/programming-9/php-pfsockopen-552084/ http://stackoverflow.com/questions/14268018/concurrent-use-of-a-persistent-php-socket http://devzone.zend.com/303/extension-writing-part-i-introduction-to-php-and-zend/#Heading3 http://stackoverflow.com/questions/242316/how-to-keep-a-php-stream-socket-alive http://php.net/manual/en/install.fpm.configuration.php https://www.google.com/search?q=recv%28%29+failed+%28104:+Connection+reset+by+peer%29+while+reading+response+header+from+upstream+%22502%22&ei=mC1XUrm7F4WQyAHbv4H4AQ&start=10&sa=N&biw=1920&bih=953&dpr=1

    Read the article

< Previous Page | 901 902 903 904 905 906 907 908 909 910 911 912  | Next Page >