Search Results

Search found 92933 results on 3718 pages for 'server side'.

Page 706/3718 | < Previous Page | 702 703 704 705 706 707 708 709 710 711 712 713  | Next Page >

  • Dir all files to output.log, including message "File Not Found"

    - by user316687
    I'm trying to dir a bunch of files with dos command: dir My dir.bat file: dir E:\documentos\57\Asiento\01\"Asiento 3 Modificacion de Estatuto.doc" dir E:\documentos\134\Asiento\01\"File Does Not Exist.doc" dir E:\documentos\55\Asiento\01\"Asiento 5 Padron de Afiliados Segunda Entrega.doc" The second one doesn't exist. Then, when running my bat: C:\myuser>E:\dir.bat > output.log I open output.log and don't find any message about the file that was not found. Output.log : E:\documentos>dir E:\documentos\57\Asiento\01\"Asiento 3 Modificacion de Estatuto.doc" Volume in drive E is New Volume Volume Serial Number is 0027-F7F6 Directory of E:\documentos\57\Asiento\01 20/12/2005 06:41 p.m. 40,960 Asiento 3 Modificacion de Estatuto.doc 1 File(s) 40,960 bytes 0 Dir(s) 17,053,155,328 bytes free E:\documentos>dir E:\documentos\134\Asiento\01\"File Does Not Exist.doc" Volume in drive E is New Volume Volume Serial Number is 0027-F7F6 Directory of E:\documentos\134\Asiento\01 E:\documentos>dir E:\documentos\55\Asiento\01\"Asiento 5 Padron de Afiliados Segunda Entrega.doc" Volume in drive E is New Volume Volume Serial Number is 0027-F7F6 Directory of E:\documentos\55\Asiento\01 08/08/2007 08:33 a.m. 40,960 Asiento 5 Padron de Afiliados Segunda Entrega.doc 1 File(s) 40,960 bytes 0 Dir(s) 17,053,151,232 bytes free Is there any way that output.log shows "File Not Found" message?

    Read the article

  • What's the advantage of OpenVPN over SSTP?

    - by Jose
    If considering Windows only environment, what's the advantage of introducing OpenVPN as the company VPN service, instead of Windows built-in protocols? Especially the new SSTP protocol already overcome the one of the weakness of PPTP, which may not go over firewall/NAT. I'm wondering is there any reason not to use Windows integrated solution. The strength of the security can be an issue but I'm not sure how different they are (I know MS VPN was vulnerable but is it still?) Thanks.

    Read the article

  • Mystery 0xc0000142 error on starting java from a service, as a different user.

    - by cpf
    This is a very convoluted setup, but effectively this is what goes down: Manager service (which I don't have control over) running as admin user X starts my executable, which then starts Java as user Y using the standard c# StartInfo.Username/Password controls. Now, from a basic (not elevated or anything, just admin) command prompt I can run that executable, and Java pops up and works fine, running perfectly under the user it should be. When the service runs the same executable, however, Java silently fails. The only hint I see is this series of events in the event viewer: Service starts "Application popup: java.exe - Application Error : The application was unable to start correctly (0xc0000142). Click OK to close the application. " (googling this reveals a lot of scam sites telling me to use their "free antivirus to fix 0xc0000142 errors easy!"... sigh) Service stops (the java shutdown propagated, which is supposed to happen) And here's what process explorer has for the failure: As you can see, everything shows as a success. Now, I think this might have something to do with the permissions (the user java.exe is running under has traverse permission for the entire drive and full permissions to Directory A, which is where the .jar is), but I just can't fathom how something that works fine from the command line (and, this is an upgrade, the previous system without the user-switching aspect works fine from the service) can fail with such a cryptic message and little showing up in logs.

    Read the article

  • Zenoss need to get freespace threshold and alerts on windows "mount points"

    - by agilenoob
    I have a WMI query that will give me all the data I need to do this but I can't figure out how to get this working in Zenoss. I know I need to set data points and a threshold, and optionaly a graph. The problem is examples of how to do this with WMI are few and very confusing. Could anyone atleast point me to documention on how to do this? WMI Query(WQL): "SELECT Caption, Capacity, Freespace FROM Win32_Volume WHERE DriveLetter IS NULL"

    Read the article

  • custom adm file for IE search providers on Windows 2003

    - by filipv
    Hi, I have been stumped by this issue for some time, I created a custom ADM template for a customer to populate the search providers in Internet Explorer 7 and 8. The custom ADM works fine and I have set 3 search providers, the problem is that I cannot change them (the customer wants to change the entry for wikipedia from EN to NL), I edited the ADM file but the clients seem to keep on using the old settings. Removing/replacing the adm file has no effect either, the settings remain. I used the following article as a base: http://support.microsoft.com/kb/918238 For IE8 you need to work with a name instead of a UID for the default entry, that works as expected. but there seems to be no way to change the setting once in place.

    Read the article

  • Windows 2008 R2 large file copy causes Hyper-V Manager to stop responding

    - by maryeileen
    I'm using the EXPORT feature in Hyper-V to move a large Virtual Machine (VM) over a 1GB network from a Windows 2008 to a Windows 2008 R2 box (200GB) and its so intense that I get the following icon on my destination Hyper-V manager: Is this expected? Is there another way to get large file across the network and minimize this intense I/O effect? Anyones else ever seen that Do Not Enter sign? The other VMs are functional but slow, but I'm guessing that is expected.

    Read the article

  • to measure throughput of testing device connect to server via AP

    - by samantha
    Description of project- I have a test tool to which DUT connects. The test tool has an access point in it and once DUT get connected to it via mac address we check RSSI and some other features of WiFi of DUT. Now I am wondering is there is any way I can measure throughput of Device under test via mac address of DUT from server side. Test-tool has LINUX fedora 11 in it and major coding is done in c/C++ and json command. Previously, I have tried to install ftp server on test-tool and DUT can connect to it and we can measure the throughput or data transfer rate, but this is not feasible solution as it requires lot of intervention from DUT. What I am interested in is 1) To run some script on server side /test tool and it gives me throughput of bandwidth of connected device may be via mac address of DUT OR 2) Server script transfer some files/packets to DUT and we can measure the throughput. Coding is not a major challenge at this stage , I just need some tool which requires minimum intervention from DUT.

    Read the article

  • What is a quick way to report login/logout times on Windows 2003?

    - by blueberryfields
    I have about a dozen servers, and I am looking to quickly find out all of the login/logout times, for a subset of users, for all servers, during January. Is there a quick, easy way to get this information (faster and easier than manually combing through the security logs)? I would rather not replicate any work - are there any publicly posted tools or scripts that already implement a solution to this problem?

    Read the article

  • Timout dead connections to Digi PortServer TS16

    - by MT
    We are using Digi portservers for console management of our routers. Basically users telnet to the Digis on ports 2001-2016 (corresponding to the physical serial port they want to connect to). Does anyone know if there is a way to cause the digi to close/release a user's connection after an period of idle time and if possible, where that time can be specified?

    Read the article

  • Internal message system with SQL database

    - by laurens
    Hi all, I was asked to install a -rather basic- Internal message system with SQL database we could integrate with our websites. A user is logged onto the website and should then be able to go to its Inbox or outbox; of course they should be able to sent to other users. Important: It's not a smtp/pop mailserver system I'm looking for! I found something with similar functionalities with an access DB (also a possibility) http://www.planet-source-code.com/vb/scripts/ShowCode.asp?lngWId=4&txtCodeId=6859 Thanks in advance!

    Read the article

  • Cannot schedule task to run under domain user account other than current user

    - by Filburt
    On our Win 2008 machines I can't schedule tasks for domain users because the domain name does not resolve to network name but the AD dc name. The "network name" looks like ABCDEFGE-HIJKLM and the "dc" / "name" would look like ABCDEFGE-HIJKLMN. When selecting the domain user account the account qualifier will look like ABCDEFGE-HIJKLMN\task.user. This results in an "invalid account" error. When however keeping the currently logged in user it will display ABCDEFGE-HIJKLM\current.user. Does this behaviour result from the presumable "illegal" domain name? Is there a workaround for this? update I could of course log in as the desired domain account and create the task but since this account is a account used for running services I want to avoid creating a user profile on the machine.

    Read the article

  • Permissions needed to read event log messages remotely?

    - by Neolisk
    When running under a limited account, local event log messages are displaying fine, for remote computer I am getting this error: The description for Event ID ( xxxxx ) in Source ( yyyyy ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: zzzzz. Same remote computer works fine under domain administrator. I am currently experimenting with just the Event Viewer, by using Run As. Original issue is a PowerShell script which does Get-EventLog. Are there any special permissions that need to be in place to able to read event log messages remotely? Supposedly there is a simple solution in Windows 2008 and higher, i.e. just add user to Event Log Readers group. Is there anything like that for Windows 2003?

    Read the article

  • What's more cost effective, Hosting your web startup on Foss or Windows?

    - by user37899
    Hi, Not coming from the windows world, I'm confused about licensing. I think my knowledge may be out of date. Before we gave up with windows web servers (IIS 2), we used to have to pay Client Access licence's. This worked out quite expensive. Is it cheaper to host 1000's of users on Windows than use Free open source software tools? http://serverfault.com/questions/124329/network-load-balancing-efficience-and-limits. This post suggests I can pay $15 a month, for unlimited users. I certainly hope that this is unbiased view, I am a professional and use the right technology for the right job. I hope i am not feeling the wrath of a windows (or linux for that matter) fanboy. Perhaps a Microsoft certified Licensing person can clear this up. Should i be recommending to startups windows servers and products over lamp? Cheers!

    Read the article

  • What's the meaning of logging in as "[email protected]:something"

    - by Harvey Kwok
    My Windows 2008 R2 machine is joined to a domain. In the logon screen, if I type in "[email protected]:something" as the username, I can still logon properly, what's the meaning of ":something" appended at the end? I can even see the current user is displayed as "[email protected]:something" in the switch user screen. Is it a feature in Windows? Or is it just a bug? If it is a feature, what's the difference between logging in as "[email protected]" and logging in as "[email protected]:something"? Note that I tried different combinations like "mydomain\username:something" and "mydomain.com:something\username". None of them work except "[email protected]:something".

    Read the article

  • TFS2010 Hangs “Waiting for Build Agent”

    - by Qpirate
    I have asked this question over on SO the link to the question is here but i am hoping this is a better place to ask it. I have 3 VM's each running the TFS Build Host Service 1 has 1 controller and 1 agent 2 have 2 Build Agents each. Most of the time (7\10 builds) it comes back with the following error message TF215097: An error occurred while initializing a build for build definition BUILD_DEFINITION: There was no endpoint listening at http://MACHINE1:9191/Build/v3.0/Services/Controller/14 that could accept the message. This is often caused by an incorrect address or SOAP action. See InnerException, if present, for more details. and there is no errors when i do get this message. the following is the config file that i have created <configuration> <appSettings> <add key="traceWriter" value="true"/> </appSettings> <system.diagnostics> <switches> <add name="BuildServiceTraceLevel" value="4"/> <add name="API" value="4"/> <add name="Authentication" value="4"/> <add name="Authorization" value="4"/> <add name="Database" value="4"/> <add name="General" value="4"/> <add name="traceLevel" value="4"/> </switches> <trace autoflush="true" indentsize="4"> <listeners> <add name="myListener" type="Microsoft.TeamFoundation.TeamFoundationTextWriterTraceListener,Microsoft.TeamFoundation.Common, Version=10.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" initializeData="c:\logs\TFSBuildServiceHost.exe.log" /> <remove name="Default" /> </listeners> </trace> </system.diagnostics> </configuration> I do have my own custom activities in my build process but this does not seem to be a problem as sometimes the build actually does go. I have tried refreshing the template as some sites suggest. Has anyone come across a solution for this problem? or can anyone tell me how to catch these errors when they happen?

    Read the article

  • Trying to make changes to the size of the events buffer in prelude-ids auditd plugin

    - by tharris
    I am running systems using the prelude-ids plugin for auditd. When the manager is up every thing works fine however I have a requirement that when the clients can't talk to the manager they should store no more than 250MB of messages, and when they hit that point they should start deleting the oldest events. All I can find is that audispd can be set to an overflow action of ignore,syslog,suspend,single, and halt none of which meet my requirement, and several of which I really cannot use. Does anyone know a way to do this? I know the events get stored in /var/spool/prelude/auditd/global, but I can't find anything about configuring how things are stored here. There are usually several files in the global directory but only 2 of them ever go above 0 in size, data0 and data0.journal.

    Read the article

  • What could cause a program to stay in "Add/Remove Programs" even after removing from registry

    - by Ryan
    Trying to manually remove an entry from Control Panel Add/Remove Programs. (custom software, not MS KB patch or windows component and not doing anyting 'funky' like trying to stop itself form being uninstalled) Followed http://support.microsoft.com/kb/314481 removing all applicable registry keys for program from HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\ and even tried rebooting but still it persists. Double checked followed KB314481 and search for program name doesn't return any other matches in that part of the registry. Any ideas what would cause this or how to solve?

    Read the article

  • Can the users can apply Windows update without local administrator rights?

    - by AAA-Super
    My users are running on windows XP 32bit. normally WSUS automatically download and notify them to select which update want to install in the past they were in local administrator rights,now I reduce them to user rights so now they can't see the yellow notification said updated are available. Is there a way to give users permission to see the yellow notification and they can select updates by hand without local admin rights or power users? Any advice would be appreciated Thanks

    Read the article

  • Computers "applying computer settings" for a long time on start-up...why?

    - by tombull89
    Hello. Might be a bit of a slong shot but I'm stumped, along with the ICT Manager for the school I'm working it. In one of the IT rooms when you switch a computer on it will boot through BIOS fine, but when it gets to "applying computer settings" it can hang for a long time (~15 minutes). If you unplug the computer from the network it starts up fine, gets to the login screen, then you can plug the network cable in and it will work fine. I don't think it's anything to do with the fact we've been coming close to running out of IP addresses or a problem with our DHCP. Microsoft KB says apply the latest service pack, which we've done, and check a service. Servers and domian controllers are S2003, Computers and Desktops are XP. Does anybody have any thoughts on what to try?

    Read the article

  • Eventlog entry for allowed connection in Windows Firewall

    - by Jaap
    I was seeing a lot of entries in the eventlog: The Windows Filtering Platform has permitted a connection. Application Information: Process ID: 4 Application Name: System Network Information: Direction: Inbound Source Address: 10.xxx.xxx.xxx Source Port: 80 Destination Address: 10.xxx.xxx.xxx Destination Port: 31773 Protocol: 6 Filter Information: Filter Run-Time ID: 67903 Layer Name: Receive/Accept Layer Run-Time ID: 44 We have a loadbalancer which checks every second to see if the application is still running (a health check). The logs contain large amounts of this kind of entries, which makes the Event Viewer slow and it's difficult to find the more interesting logs. How do I make sure these messages don't end up in the event logs?

    Read the article

< Previous Page | 702 703 704 705 706 707 708 709 710 711 712 713  | Next Page >