Monthly Archives

Articles indexed in June 2010

Page 1341/1794 | < Previous Page | 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348  | Next Page >

  • Controlling read and write access width to memory mapped registers in C

    - by srking
    I'm using and x86 based core to manipulate a 32-bit memory mapped register. My hardware behaves correctly only if the CPU generates 32-bit wide reads and writes to this register. The register is aligned on a 32-bit address and is not addressable at byte granularity. What can I do to guarantee that my C (or C99) compiler will only generate full 32-bit wide reads and writes in all cases? For example, if I do a read-modify-write operation like this: volatile uint32_t* p_reg = 0xCAFE0000; *p_reg |= 0x01; I don't want the compiler to get smart about the fact that only the bottom byte changes and generate 8-bit wide read/writes. Since the machine code is often more dense for 8-bit operations on x86, I'm afraid of unwanted optimizations. Disabling optimizations in general is not an option.

    Read the article

  • NSIS - put EXE version into name of installer

    - by codeulike
    NSIS has a Name variable that you define in the script: Name "MyApp" It defines the name of the installer, that gets displayed as the window title, etc. Is there a way to pull the .NET Version number out of my main EXE and append it to the Name? So that my installer name would automatically be 'MyApp V2.2.0.0" or whatever?

    Read the article

  • Can Symfony simply reload a page request?

    - by Rob Wilkerson
    I have an app that receives a request from another app. It detects a value on the query string, checks that value against a cached value and, if they don't match, it needs to clear its cache and reload the page (establishing a new cache). Unfortunately, I can't find a way to tell Symfony to redirect to the current page in exactly the same format (protocol, URI path, query string, etc.). What am I missing? This is all happening in a filter on isFirstCall(). Thanks.

    Read the article

  • WPF: capturing XAML into subclassed control

    - by Sonic Soul
    hello, i narrowed down what i want my wpf button to look like using XAML. now i would like to create a sub classed button control that i can just re-use w/out having to write all that markup <Button Click="TestGridColumnButton_Click" Background="Transparent" Width="16" Height="16" Margin="0,0,0,0" Padding="0,0,0,0" BorderBrush="{x:Null}"> <Button.Template> <ControlTemplate> <Image HorizontalAlignment="Center" VerticalAlignment="Center" Style="{StaticResource SourceStyle}" /> </ControlTemplate> </Button.Template> </Button> how can i set all these properties using C# ?

    Read the article

  • News Aggregater of sorts

    - by shinjuo
    There is a website that my company uses that updates information about 3 specific things throughout the day. We use the information from 1 of them and what we are wanting to do is pull this information as it is added to their site and add it to a page of our own to view easier. Is this even possible? Can anyone point me in the direction of setting this up? It is all text that we want to pull.

    Read the article

  • Correcting CS0009 Error When Creating Integration Services Project

    - by ajdams
    Tried to open an SSIS project I had been working on today and received this lovely error: Unable to generate temporary class (result=1) error CS0009: Metadata file 'c:\WINDOWS\assembly\GAC_MSIL\System.Xml\2.0.0.0_b77a5c561934e089\System.XML.dll' could not be opened -- 'No metadata was found.' Anyone know why this happens and how to correct it, I've Googled and haven't found any valid solutions relating directly to SSIS. It is only happening with BIDS 2008 and SSIS project types and I tried the same packages (as well as creating a new one) on my other machine and it was fine. Any ideas? Thank you.

    Read the article

  • Get metadata out of a webHttpBinding endpoint

    - by decyclone
    Hi, With a reference to my previous question, I would like to know how would I extract information of a WCF service from a client application to know what methods/types are exposed if the service exposes only one endpoint that uses webHttpBinding? Just to summarize, in my previous question, I came to know that an endpoint using webHttpBinding does not get exposed in the generated WSDL because it would be a JSON endpoint and is just not compatible.

    Read the article

  • Obtaining Nearby Wifi In C Using VS2010

    - by WizardsSleeve
    Hi All, I am trying to identify a method for obtaining nearby wifi access points using C in Windows. I am coding in Visual Studio 2010. I have read the necessary documentation but am lacking in guidance on how to implement code that would accomplish this. I am specifically interested in obtaining the MAC address of nearby access points or at a minimum the MAC address of the currently connected Wifi access point. Is it possible to do this using WMI in Windows, specifically on Windows XP SP3 and later? Any pointers on how to do this are greatly appreciated.

    Read the article

  • Internet Explorer buggy when accessing a custom weblogic provider

    - by James
    I've created a custom Weblogic Security Authentication Provider on version 10.3 that includes a custom login module to validate users. As part of the provider, I've implemented the ServletAuthenticationFilter and added one filter. The filter acts as a common log on page for all the applications within the domain. When we access any secured URLs by entering them in the address bar, this works fine in IE and Firefox. But when we bookmark the link in IE an odd thing happens. If I click the bookmark, you will see our log on page, then after you've successfully logged into the system the basic auth page will display, even though the user is already authenticated. This never happens in Firefox, only IE. It's also intermittent. 1 time out of 5 IE will correctly redirect and not show the basic auth window. Firefox and Opera will correctly redirect everytime. We've captured the response headers and compared the success and failures, they are identical. final boolean isAuthenticated = authenticateUser(userName, password, req); // Send user on to the original URL if (isAuthenticated) { res.sendRedirect(targetURL); return; } As you can see, once the user is authenticated I do a redirect to the original URL. Is there a step I'm missing? The authenticateUser() method is taken verbatim from an example in Oracle's documents. private boolean authenticateUser(final String userName, final String password, HttpServletRequest request) { boolean results; try { ServletAuthentication.login(new CallbackHandler() { @Override public void handle(Callback[] callbacks) throws IOException, UnsupportedCallbackException { for (Callback callback : callbacks) { if (callback instanceof NameCallback) { NameCallback nameCallback = (NameCallback) callback; nameCallback.setName(userName); } if (callback instanceof PasswordCallback) { PasswordCallback passwordCallback = (PasswordCallback) callback; passwordCallback.setPassword(password.toCharArray()); } } } }, request); results = true; } catch (LoginException e) { results = false; } return results; I am asking the question here because I don't know if the issue is with the Weblogic config or the code. If this question is more suited to ServerFault please let me know and I will post there. It is odd that it works everytime in Firefox and Opera but not in Internet Explorer. I wish that not using Internet Explorer was an option but it is currently the company standard. Any help or direction would be appreciated. I have tested against IE 6 & 8 and deployed the custom provider on 3 different environments and I can still reproduce the bug.

    Read the article

  • Installing SharePoint 2010 in one machine with built in database

    - by sreejukg
    It is very easy to deploy SharePoint 2010 in a single server using the built-in database. Normally one need to choose such installation for evaluation purposes. When installing with default settings, setup installs Microsoft SQL server 2008 express database along with SharePoint. After installing SharePoint, you need to run SharePoint products and technology configuration wizard which will install central admin website and creates the configuration database and content database for SharePoint sites. Limitations 1. You can not perform this installation on a domain controller 2. The maximum size for express edition database is 4 GB SharePoint 2010 only supports 64 bit operating systems. The installation steps are for windows server r2 64 bit enterprise edition. Installation steps The first screen for the installation is as follows As a first step you need to install the s/w prerequisites. Click on the corresponding link Click next, here you have to agree on the license terms. Select the checkbox and then click next. The installation will starts. The progress will be updated in the screen. This may take some time as during this process, there are some components needs to be downloaded from internet. Make sure you are connected to the internet, then only the installation will become a success. If any error occurs, it will display the error, you need to configure in order to continue. If everything ok you will receive the following success page. Click finish to exit the installation window. Now from the first screen, select Install SharePoint server. This will install SharePoint and SQL server 2008 express edition. First you need to enter the product key for SharePoint. Enter the product key and clicks continue. Now you need to accept the license agreement. Select the checkbox and click on continue. Select the installation type you want.   Now click on the standalone button. In production scenario, you need to select the server farm installation. This article only cover the first option, installing server farm is not in the scope of this article. Once you click on the standalone, the installation starts and you can view the progress as below. If any error occurred during installation, you will get the details and link to the log file. Refer log file and fix the corresponding issue and then start the installation again. If installation completes without any error, you will see the below screen. Make sure you selected the check box “Run the SharePoint products Configuration Wizard now” and click close. The SharePoint products configuration wizard starts. Click next; you will get the following warning Click yes and the configuration steps starts. You can view the progress for each step. Once completed the below screen appears to the user. Click finish to complete the installation. Now SharePoint installation is completed. You can navigate to SharePoint central administration website from the administrative tools and start building your portal. Good luck

    Read the article

  • From the Coalface - 3 - Work as hard as you can to be as lazy as you can!

    - by TATWORTH
    The saga of the Change Log A recent conversation reminded me of the need for change logs within a database, to record when various change scripts were run. Creating such the required table is simple. A typical table for this consists of: Id - identity Integer primary key ChangeFileName - NVARCHAR(128) to hold the name of the file run. DateAdded - DateTime non-null with default value of getutcdate() Purpose - NVARCHAR(128) Rerunnable - Bit non-null default 0. By good design of the table only two data values normally need to be supplied. Two stored procedures, one for inserting data and one to list in reverse sequence the log complete the database essentials. The complete implementation can be found in the CommonData solution at http://CommonData.CodePlex.Com By including a call the add Change Log stored procedure, each script can log its name and purpose for posterity. The scripts that were applied to say the UAT system and their sequence of application can be readily identified for running on the Live system. Formatting XML XML is often produced as one continous string with no embedded CR/LF. To get it into human readable form, open it in visual studio, swap to another tab and back and click the format document button. The XML will then be nicely formatted!

    Read the article

  • imagecreatefromjpeg() stops working after server upgrade

    - by John Conde
    We have a server located at a local company's place of business running Solaris/Apache/PHP. They recently did an update to Solaris, Apache, and PHP (security update patches, etc.). Unfortunately it has caused the image manipulation portion of our software to break. imagecreatefromjpeg() is now generating the following error: Warning: imagecreatefromjpeg() [function.imagecreatefromjpeg]: '/path/to/file/filename.jpg' is not a valid JPEG file in /path/to/file/Image.class.php on line XX No PHP code was changed during the server upgrade and it was fully functional before the software upgrades. I checked the files being passed to imagecreatefromjpeg() and they are indeed valid (they open successfully in both image editing software and in my browser). I checked the permissions of the directory from which the files are being opened and they do have read permission. GD library is enabled. I'm not sure what else I can check. Based on the scenario above I am guessing something changed in the software but I don't know what it could be. PHP was version 5.2.5 and is now 5.2.13. I appreciate any guidance as to what could be cause of this issue.

    Read the article

  • Ubuntu 9.10 LiveCD stalls after "Install Ubuntu" selected from boot menu on eMachines

    - by nicorellius
    I am trying to install Ubuntu 9.10 from the ISO on a CD (it needs to be this version) on an eMachine with a brand new Seagate hard disk. The CD boots OK, and I choose the language. Then I am presented with the boot menu: Try Ubuntu Install Ubuntu etc I have tried the top two choices several times (trying Ubuntu and installing it), but each and every time the installation stalls and the disc stops spinning right after I hit enter after choosing the option I want. I have tried different CD/DVD drives, changing the jumpers on both CD drives, different hard drives, and nothing works. Maybe there is a BIOS setting that is choking the installation? Any help would be appreciated. Edit - I just tried running the hard drive as the master on the primary IDE and the CD drive as the slave on the primary with the same results. Maybe flash the BIOS?

    Read the article

  • C# Windows Aero Style Wizard Control

    I have been a fan of the Windows Aero styled windows since Aero was first introduced in Windows Vista. However, there is little to no Aero inclusion in the .NET framework, so I set out to create my own Windows Aero themed form.

    Read the article

  • Application error: fault address 0x00012afb (Expert)

    - by Christian Almeida
    Hi, I need some "light" to get a solution. Probably there are tons of things that cause this problem, but maybe somebody could help me. Scenario: a Windows server running 24/7 a PostgreSQL database and others server applications (for processing tasks on database, etc...). There are differents servers scenarios (~30), with different hardware and windows versions (XP SP3/ WinServer, etc... all NT based). All aplications were written in Delphi7, and link to DLLs (in D7 also). After some days (sometimes a week, sometimes a couple of months), Windows begins to act strange, like not opening start menu, some buttons are missing in dialogs. And soon some applications do not open, raising a event on eventviewer: Faulting application x, version y, faulting module kernel32.dll, version 5.1.2600.5781, fault address 0x00012afb In mean while, others applications open fine, like notepad, iexplore, etc... but SOME of my applications don't, with only event log described above. But if we do not restart system, in a few days even cmd.exe stops open, (and all other applications) with same error on eventlog. I've tried to find 'what' can cause this, but with no sucess. So, and any advice will be welcome. Thanks in advance.

    Read the article

  • Does Flash Builder 4 now use AIR 2?

    - by John Isaacks
    I just got CS5 master suite which includes Flash Builder 4 and Flash CS5 Pro. When I create a new AIR app in CS5 pro it says "AIR 2" but when I create a new AIR project in Flash Builder I do not see anything indicating that it is AIR 2 or 1.5? Is there a way to tell which AIR runtime it is using?

    Read the article

  • Make C# application Group Policy aware

    - by Stefan Koell
    I want to make my app GPO aware. I know that it's basically just reading from a specific registry path but I still have some questions: How do I detect GPO refreshes? There's RegisterGPNotification here: http://msdn.microsoft.com/en-us/library/aa374404(VS.85).aspx but is there anything ready baked for C# out there or at Microsoft? What's considered best practice: is the machine policy stronger than the user policy or is the user policy overruling the machine policy? Anyone, who wants to share some experience in that area? Thanks, Stefan

    Read the article

  • Merge two data frames together that have the same variable names and data types

    - by Brandon
    I have tried the merge function to merge two csv files that I imported. They both have the same variable names and data types but each time I run merge all that I get is an object that contains the names of the two data frames. I have tried the following: # ex1 obj <- merge(obj1, obj2, by=obj) # ex2 obj <- merge(obj1, obj2, all) and several other iterations of the above. Is merge the correct function? If so, what am I doing wrong?

    Read the article

  • Obtaining Nearby Wifi In C

    - by WizardsSleeve
    I am trying to identify a method for obtaining nearby wifi access points using C in Windows. I am coding in Visual Studio 2010. I have read the necessary documentation but am lacking in guidance on how to implement code that would accomplish this. I am specifically interested in obtaining the MAC address of nearby access points or at a minimum the MAC address of the currently connected Wifi access point. Is it possible to do this using WMI in Windows, specifically on Windows XP SP3 and later? Any pointers on how to do this are greatly appreciated.

    Read the article

  • 404 Error using Flash Builder 4 BlazeDS wizard

    - by codeflayer
    Hello again Stackoverflow! My issue this time around is trying to use the new DCD BlazeDS wizard in Flash Builder 4. If I set my project up as a combined Java/Flex app I am unable to connect to the RDS servlet using the wizard. I get a 404 error every time. I'm certain the service is set up correctly since my app can access the exposed java classes and BlazeMonster can see the exposed services. Is anyone else having this issue and if so has anyone found a work-around? I'd very much like to use the code generation features of the wizard for my project. Thanks as always, Codeflayer

    Read the article

  • Is there a way to configure timeout for speculative execution in Hadoop?

    - by S.O.
    I have hadoop job with tasks that are expected to run for significant length of fime (few minues). However hadoop starts speculative execution too soon. I do not want to turn speculative execution completely off but I want to increase duration of time hadoop waits before considering job for speculative execution. Is there a config option to control this timeout? Thanks

    Read the article

  • Clojure lots of threads

    - by Timothy Baldridge
    I just got done watching Rick Hickey's "Clojure Concurrency" talk, and I have a few questions about threads. Let's say I have a situation with lots of Agents, let's say 10,000 of them running one machine. I'd rather not have 10,000 CPU threads running at once, but I don't want threads to be blocked by the actions of other threads. In this example I won't really be waiting for replies, instead each Agent will be sending a message or two, and then waiting until it gets a message. How would I structure a program like this without getting 10k OS threads which would probably end up slowing the system down.

    Read the article

< Previous Page | 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348  | Next Page >