Search Results

Search found 7805 results on 313 pages for 'high voltage'.

Page 105/313 | < Previous Page | 101 102 103 104 105 106 107 108 109 110 111 112  | Next Page >

  • Finegrain Performance Reporting on svchost.exe

    - by Randolpho
    This is something that's always bothered me, so I'll ask the serverfault community. I love me some Process Explorer for keeping track of more than just the high-level tasks you get in the Task Manager. But I constantly want to know which of those dozen services hosted in a single process under svchost is making my processor spike. So... is there any non-intrusive way to find this information out?

    Read the article

  • Why apcupsd won't see the UPS connected to the USB posrt on FreeBSD 8.0 amd64

    - by Max Kosyakov
    Hello, Recently I installed an apcusbd on a FreeBSD 8.0 amd64 box via ports system. It installed perfectly but it won't run. Here what is says in the log: FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device It appeared that HID driver picked the /dev/ugen4.2 which could cause the apcusb being unable to find the device. After I had discovered this, I rebuilt the kernel and removed the hid driver. Now it just shows "ugen4.2: <Tripp Lite> at usbus4" and no uhid0 device appears. Nevertheless the problem persisted. I tried to leave the DEVICE config setting blank --- won't help. Then I specified the particular device in the config, but it did not help either. Below you is the output of several commands that can provide some useful information on my case. server# /usr/local/etc/rc.d/apcupsd start Starting apcupsd. server# tail /var/log/messages | grep apcupsd Jun 17 22:30:00 server apcupsd[1520]: apcupsd FATAL ERROR in generic-usb.c at line 636 Cannot find UPS device -- For a link to detailed USB trouble shooting information, please see . Jun 17 22:30:00 server apcupsd[1520]: apcupsd error shutdown completed server# cat /usr/local/etc/apcupsd/apcupsd.conf ## apcupsd.conf v1.1 ## UPSCABLE usb UPSTYPE usb DEVICE /dev/ugen4.2 LOCKFILE /var/lock UPSCLASS standalone UPSMODE disable server# dmesg | grep '^u' uhci0: port 0xa800-0xa81f irq 16 at device 26.0 on pci0 uhci0: [ITHREAD] uhci0: LegSup = 0x0f00 usbus0: on uhci0 uhci1: port 0xa880-0xa89f irq 21 at device 26.1 on pci0 uhci1: [ITHREAD] uhci1: LegSup = 0x0f00 usbus1: on uhci1 uhci2: port 0xac00-0xac1f irq 18 at device 26.2 on pci0 uhci2: [ITHREAD] uhci2: LegSup = 0x0f00 usbus2: on uhci2 usbus3: EHCI version 1.0 usbus3: on ehci0 uhci3: port 0xa080-0xa09f irq 23 at device 29.0 on pci0 uhci3: [ITHREAD] uhci3: LegSup = 0x0f00 usbus4: on uhci3 uhci4: port 0xa400-0xa41f irq 19 at device 29.1 on pci0 uhci4: [ITHREAD] uhci4: LegSup = 0x0f00 usbus5: on uhci4 uhci5: port 0xa480-0xa49f irq 18 at device 29.2 on pci0 uhci5: [ITHREAD] uhci5: LegSup = 0x0f00 usbus6: on uhci5 usbus7: EHCI version 1.0 usbus7: on ehci1 uart0: port 0x3f8-0x3ff irq 4 flags 0x10 on acpi0 uart0: [FILTER] usbus0: 12Mbps Full Speed USB v1.0 usbus1: 12Mbps Full Speed USB v1.0 usbus2: 12Mbps Full Speed USB v1.0 usbus3: 480Mbps High Speed USB v2.0 usbus4: 12Mbps Full Speed USB v1.0 usbus5: 12Mbps Full Speed USB v1.0 usbus6: 12Mbps Full Speed USB v1.0 usbus7: 480Mbps High Speed USB v2.0 ugen0.1: at usbus0 uhub0: on usbus0 ugen1.1: at usbus1 uhub1: on usbus1 ugen2.1: at usbus2 uhub2: on usbus2 ugen3.1: at usbus3 uhub3: on usbus3 ugen4.1: at usbus4 uhub4: on usbus4 ugen5.1: at usbus5 uhub5: on usbus5 ugen6.1: at usbus6 uhub6: on usbus6 ugen7.1: at usbus7 uhub7: on usbus7 uhub0: 2 ports with 2 removable, self powered uhub1: 2 ports with 2 removable, self powered uhub2: 2 ports with 2 removable, self powered uhub4: 2 ports with 2 removable, self powered uhub5: 2 ports with 2 removable, self powered uhub6: 2 ports with 2 removable, self powered uhub3: 6 ports with 6 removable, self powered uhub7: 6 ports with 6 removable, self powered ugen4.2: at usbus4 server#

    Read the article

  • No architecture vs architecture-specific binaries

    - by Aaron
    From what I understand, the noarch suffix means that it's architecture independent and should work universally. If this is the case, why should I install architecture-specific packages at all? Why not just go straight for the noarch? Are there optimizations in the x86 or x64 binaries that aren't found in the noarch binaries? What's best for high performance applications? Folding@Home does this with their controller:

    Read the article

  • APC ups es 700 randomly overload

    - by Matteo Mosca
    First of all, I live in Italy, Europe, so keep this in mind for Volt/Watt considerations. Standard voltage in Italian apartments is 220V. In my living room I have 2 APC ups, one being an ES-550 and the other an ES-700 They each have 4 slots for surge protection only, and 4 slots for surge protection + battery backup. Just to give all the information, they both got their battery replaced less than one month ago. The ES-550 works fine, without any problem. On the battery I have connected: Pc Monitor Sony Bravia 46'' 4th slot is empty The ES-700 has the following on battery: Xbox 360 Ps3 (standby when not used) Wii (standby when not used) Netgear 8 port switch (always on) Here's what happens: the ES-700, randomly, but mostly at night when I'm sleeping, goes like "overload", with the constant beep. If I try to shut it off keeping the power button pressed, nothing happens. The only thing that works is unplugging random stuff (sometimes unplugging 1 console works, other times I have to unplug all 4 devices). Every time this happens the problem is "real", meaning the 4 devices become unpowered, so it's not just an "alarm no working properly" problem. While I'm sleeping, of course, the power usage is what described on the list, 2 devices on standy, 1 off and 1 on. Today it happened again while I was playing with my Ps3. I unplugged it, problem went away. I plugged it again, and it kept working fine. I just can't figure out what's the problem. The only additional info I can provide is that this behaviour started after a big power outage last december 26 (a blackout that lasted almost all day) but the "surge protection" part of those UPS should be there for those problems, to leverage peaks when power goes away or gets restored. Another funny thing is, althought it might not be related, for a couple of days after that event the Wii was unable to power on, I thought its power transformer was broken, but then it suddenly started working again. I can be sure it's not the Wii overloading the UPS because the overload happens even if I leave the Wii unplugged. Any suggestion is really appreciated, and I can provide any additional info, if needed, that didn't come to mind right now. Thanks.

    Read the article

  • Revolutionary brand powder packing machine price from affecting marketplace boom and put on uniform in addition to a lengthy service life

    - by user74606
    In mining in stone crushing, our machinery company's encounter becomes much more apparent. As a consequence of production capacity in between 600~800t/h of mining stone crusher, stone is mine Mobile Cone Crushing Plant Price 25~40 times, effectively solved the initially mining stone crusher operation because of low yield prices, no upkeep problems. Full chunk of mining stone crusher. Maximum particle size for crushing 1000x1200mm, an effective answer for the original side is mine stone provide, storing significant chunks of stone can not use complications in mines. Completed goods granularity is modest, only 2~15mm, an effective option for the original mine stone size, generally blocking chute production was an issue even the grinding machine. Two types of material mixed great uniformity, desulfurization of mining stone by adding weight considerably. Present quantity added is often reached 60%, effectively minimizing the cost of raw supplies. Electrical energy consumption has fallen. Dropped 1~2KWh/t tons of mining stone electrical energy consumption, annual electricity savings of one hundred,000 yuan. Efficient labor intensity of workers and also the atmosphere. Due to mine stone powder packing machine price a high degree of automation, with out human make contact with supplies, workers working circumstances enhanced significantly. Positive aspects, and along with mine for stone crushing, CS series cone Crusher has the following efficiency traits. CS series cone Crusher Chamber is divided into 3 unique designs, the user is usually chosen in accordance with the scenario on site crushing efficiency is high, uniform item size, grain shape, rolling mortar wall friction and put on uniform in addition to a extended service life of crushing cavity-. CS series cone Crusher utilizes a one of a kind dust-proof seal, sealing dependable, properly extend the service life of the lubricant replacement cycle and parts. CS series Sprial Sand washer price manufacture of important components to choose unique materials. Each and every stroke left rolling mortar wall of broken cone distances, by permitting a lot more products into the crushing cavity, as well as the formation of big discharge volume, speed of supplies by way of the crushing Chamber. This machine makes use of the principle of crushing cavity, also as unique laminated crushing, particle fragmentation, so that the completed product drastically improved the proportions of a cube, needle-shaped stones to lower particle levels extra evenly.

    Read the article

  • How do I login to SQL Server without having to use "Run as Administrator" when starting Management S

    - by MedicineMan
    When I start Management Studio, unless I use the "Run as Administrator" selection, I cannot login to my local SQL Server. Is this normal? I am a normal developer and don't believe I have a need for high security on my local machine. I'm running SQL Server 2008, Windows 7. The error I get is: Cannot connect to (local) Additional Information Login failed for user 'MYCOMPUTER\MyName'. (Microsoft SQL Server, Error: 18456)

    Read the article

  • 4 Magento Requests per second = 210 mbit memcache bandwith?

    - by Karsten
    After searching serverfault for similar questions without success, these are my numbers for one magento instance, running on multiple servers: After varnish about 4 requests per second hit the webservers The magento cache is configured to use one separate memcache server where I'm measuring about 210 Mbit/s bandwith usage. Compared to other projects, magento and non-magento, this number seems way off (as in extremely high). I'd like to get some data to compare to, or even better, if you have any idea what exactly causes this/how to find it and how to improve the situation.

    Read the article

  • How to get a good clean newspaper scan?

    - by itsadok
    I tried a few times to scan newspaper articles, but the images I got were always blotchy and with bad colors (sort of like this). Sometimes I see some really good scans, like this. What is the trick to get such good results? Do I need some high-quality scanner, or do I need some good photoshop filters? If there was something I could do using free tools it would be awesome.

    Read the article

  • Tiff not displaying correctly on Mac

    - by user348935
    Hi, I have a collection of .tif files but when I open them on my Mac 10.5 they show up as solid black and I don't know why. thanks Upon further inspection at really high brightness there are some out of focus objects viewable. It looks as if I am getting the first couple bits of each pixel but not the entire range of values.

    Read the article

  • apcupsd on Linux does not report on APC BackUPS Pro 900

    - by lserni
    From what documentation I could find, the UPS should be (is!) supported by Linux and ought to work with apcupsd. I looked for specific problems such as the infamous Microlink protocol, and found none. I have found a feedback from a guy in UK that reports using this very model on a not-too-different OS version (his OpenSuSE 12.1, mine 12.3 x86_64). The USB port is detected, lsusb reports Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply and lsusb -v -s002:003 confirms and expands: Bus 002 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supply Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x051d American Power Conversion idProduct 0x0002 Uninterruptible Power Supply bcdDevice 0.90 iManufacturer 1 American Power Conversion iProduct 2 Back-UPS RS 900G FW:879.L4 .I USB FW:L4 bNumConfigurations 1 Configuration Descriptor: [...] Interface Descriptor: [...] bInterfaceClass 3 Human Interface Device bInterfaceSubClass 0 No Subclass bInterfaceProtocol 0 None iInterface 0 HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.00 bCountryCode 33 US bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 1134 Report Descriptors: ** UNAVAILABLE ** Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 100 Device Status: 0x0000 (Bus Powered) The kernel recognizes this and duly sets up crw------- 1 root root 180, 96 Nov 4 16:11 /dev/usb/hiddev0 As far as I know, everything is as it should be. I have put the standard configuration in /etc/apcupsd/apcupsd.conf (which is Unix-terminated, ASCII-only, no BOM (just in case)) UPSCABLE usb UPSTYPE usb DEVICE (I have also tried commenting out DEVICE, and setting a device of /dev/puppa results in an access attempt to /dev/puppa, not some /var/lib/dev/puppa or /dev/puppa\r\n). Yet, what apcaccess tells me is VERSION : 3.14.10 (13 September 2011) suse CABLE : USB Cable DRIVER : USB UPS Driver UPSMODE : Stand Alone STARTTIME: 2013-11-04 16:24:22 +0100 MODEL : STATUS : NOBATT LINEV : 000.0 Volts LOADPCT : 0.0 Percent Load Capacity BCHARGE : 000.0 Percent TIMELEFT : 0.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds SENSE : Low LOTRANS : 000.0 Volts HITRANS : 000.0 Volts It doesn't recognize the model, and reports no battery (and no voltage). This confirms that it's not the Microlink problem, or it would report the battery status, if precious little else. If I disconnect the USB cable, I get an apcupsd message to the effect that communications have been lost; and I get the "communication restored" broadcast too, if I reconnect the cable. apcupsd is monitoring. So everything tells me that it should work -- only it doesn't. Does anyone spot what I'm missing?

    Read the article

  • Problems connecting Clariion LUNS to Solaris 10

    - by vialde
    I've got a Clariion San and a Solaris 10 server with an emulex HBA. The Thin LUNS are visible in Solaris and I can happily format the raw devices. Unfortunately that's all I can do. All other operations result in I/O errors. I'm running current versions of PowerPath and Solaris is patched as high as it'll go. Anyone have any similar experiences?

    Read the article

  • Script or Batch File to Automate Logon from Welcome Screen

    - by Guy Thomas
    Is there a script or batch file to automate the log-on process from the XP Welcome screen? As all details are the same Username, Password, and Domain in a room of 30 machines. The reason I don't use Windows AutoAdminLogon is I only want to logon temporary at different times as a user to run such things as online test for a class of high school students without the students logging on individually first, also it would be useful for admin tasks if I can change/specify the user details.

    Read the article

  • How to interpret Rackspace server diagnostics?

    - by Ben
    We've been having some trouble lately with our site timing out during times of high traffic. We're working on a number of things to resolve it. During this process I came across our server diagnostics page on Rackspace, and it has the following line: The host server's load is: 0.08 0.08 0.03 1/204 2437 I couldn't find an explanation on their site or Google. Can anyone explain what these numbers mean? For I am a lowly programmer. Much appreciated, -Ben

    Read the article

  • Securing DRAC/ILO

    - by The Diamond Z
    This might be a dumb question but DRAC/ILO both have HTTP server interfaces. If I were trolling IP's port 80 on and I came across such a page I'd know it to be a high value target in the sense that if I can crack it, I can take control of the server to some extent (potentially installing another OS). Other than changing the port, what are the best practices for securing DRAC/ILO on public Internet facing machines?

    Read the article

  • Tiff not displaying correctly on Mac OS X

    - by user348935
    I have a collection of .tif files but when I open them on Mac OS X 10.5 they show up as solid black and I don't know why. thanks Upon further inspection at really high brightness there are some out of focus objects viewable. It looks as if I am getting the first couple bits of each pixel but not the entire range of values.

    Read the article

  • Does Apache spawn piped logger on each HTTP request?

    - by Xepoch
    I am examining a high-volume Apache prefork site and noticing that many log entries such as: CustomLog '|/foo/bar/cronolog -foo -bar' RewriteLog '|/foo/bar/cronolog -bar -foo' When apache logs the request or the rewrite is cronolog spawned for EACH request or is the pipe opened and written-to for the lifetime duration of the preforked apache process? (This was asked on stackoverflow but I'll remove from there as more applicable here I think.)

    Read the article

  • Secure data hosting...

    - by kylex
    I've looked online and can't seem to find a proper answer. We have a client that requires very sensitive data be stored in a database. Is there a hosting company that provides high-level database security (this is for a bank).

    Read the article

  • What are the default/best bluetooth packages for Ubuntu 9.10?

    - by Igoru
    I've had some problems with Bluetooth in my Ubuntu 9.10, and ended up by uninstalling everything related. I would like to know what are the default packages for BTH in Ubuntu, and what are your recommendations (like blueman or thing like this). I have a high-end cellphone and would like to use everything that's possible, talking about bluetooth, with it (a samsung scrapy touch, or GT-B3410).

    Read the article

  • Apache 2.2.14: SSLCARevocation location

    - by Doc
    I am installing a .crl in my apache config. It looks like this: VirtualHost default DocumentRoot "web" ServerName example.com SSLEngine on SSLCertificateFile "cert.crt" SSLCertificateKeyFile "key.key" SSLCertificateChainFile "cert.ca-bundle" SSLProtocol -all +SSLv3 SSLCipherSuite SSLv3:+HIGH:+MEDIUM Directory Order deny,allow Allow from all SSLCACertificateFile "ClientRootCert.crt" SSLVerifyClient require SSLVerifyDepth 3 SSLCARevocationFile "CRLList.crl" Directory VirtualHost When Apache is started, I get the error: SSLCARevocationFile not allowed here When I place SSLCARevocationFile above the Directory tag, Apache starts, but all client certs are rejected with the message: ssl_error_expired_cert_alert (both revoked and active certs) How to solve this?

    Read the article

  • install php on server08 manaully

    - by justSteve
    Looking to install php on a 08 box already holding iis/sql box. I've tried the webinstaller a couple times but the installer locks before completion or managing to echo any sort of error message. Before hunting down a manual install how-to i wonder if the box is trying to tell me something i should be paying attention to. PHP running alongside IIS _must be supported or one would expect that error message to be kinda high on the list. any gochas to beware of? thx

    Read the article

  • Dangers of Running Computers w/o Air Conditioning

    - by Daniel Bingham
    I recently moved in to an apartment with out air conditioning. This is fine most of the time as I am in upstate New York. It only ever gets above the high 70s during the hottest of the summer months. And when it does, I'm stubborn enough that I'll just deal with wearing minimal clothing around the house. However, I'm worried about my computers. I'm a software developer and gamer, so many of my machines are very high powered. And at least one of them is a server that must be left on 24/7 (not just a game server - also serves multiple websites). I've never before had to worry about the heat too much, as I always lived in buildings with central air. The in building temperature rarely got much above 70 F. All of the machines I built had good enough air cooling that I never saw a problem. Now the temperature in building is pushing 100F and I'm worried that the machines will not be able to keep themselves cool enough by simply blowing already hot air over themselves. The hottest of them I've turned off. However, the server I cannot. It's an old Dell (not custom build) that runs on a Pentium 4 (2.2GHz). It only has a single hard drive, integrated video. And it'd not running any processor intensive servers. Just basic LAMP. It used to run a MUD server, but that's off for now. So it should be idling most of the time. I haven't been able to find any sort of built in temperature sensors in the hardware... at least not any that the programs I've found in the Debian repository can read. And it's an inherited machine to which I do not have the full specs, so I don't know the tolerances anyway. How worried should I be about it melting down on me? How worried should I be about the hard drive melting or becoming corrupted? To generalize the question for other people, what are the safe temperature tolerances for most machines. How widely does it vary, and how does one go about determining when their machine is running too hot and needs to be shut down?

    Read the article

  • finding audio driver

    - by Jason S
    I have a soundcard in my new PC at work that does not have the right driver installed, and I'm not sure what the manufacturer is. (it's a generic PC running Windows XP) Is there a way to figure out what device it is w/o having to open the thing up or pester my IT department? When I look at it in Device Manager it says IDT High Definition Audio CODEC and when I look around in the Properties dialog boxes there's a Device Instance ID of HDAUDIO\FUNC_01&VEN_111D&DEV_76C1&SUBSYS_12974001&REV_1001\4&3612FC2B&0&0001

    Read the article

< Previous Page | 101 102 103 104 105 106 107 108 109 110 111 112  | Next Page >