  • rpd over https using a linux client

    - by Nils
    My employer switched from vpn and rdp to using what our admin calls "rdp over https". Since that switch I find myself unable to connect to the "new" rdp server. I think the progress is as follows: A rdp gateway-server is connected via tls the requested sever (different from the gateway-server) is then connected through the tls connection. In windows mstsc-settings the server name is the "internal network name" of the machine I wish to connect. And on the last tab (in German it is called "leistung" - could be activity) I go to the "connection from everywhere" settings and set the gateway-server under gateway-server. Now: Is there any way to use this scenario under linux (apart from a virtual machine running Windows)? I am interested in free ideas (e.g. is it possible to create a tls tunnel and connect through that using freerdp/rdesktop?) non-free ideas. As long as they work I'll worry about the costs later. Free ideas would be better :-)

    Read the article

  • Google Search w/ Chrome Incognito w/ Gnome Do

    - by jrc03c
    I've installed Google Chrome as my default browser in Ubuntu, and recently installed Gnome Do and enabled the Google Search plugin. The Google Search from Gnome Do works exactly as expected but for one thing: Chrome (which is typically set to open in "incognito" mode) does not open in "incognito" mode. The shortcuts on my desktop, taskbar, and menus all have the --incognito flag attached (which works just fine), but the browser refuses to open in this mode when launched from Gnome Do. Any suggestions? Also, please note the settings for the Google Search plugin in Gnome Do: It's obvious that Gnome Do just passes the Google Search blindly to the default browser. In other words, there are no configurable settings specifically for Chrome. Any thoughts?

    Read the article

  • I can't launch any Win8 apps after upgrading to Windows 8.1

    - by locka
    I just upgraded to 8.1 and now none of the Metro apps start. The issue is that if I start any metro app, including the Store and PC Settings they immediately fail. The classic desktop is fine, as are standard programs, it's just the metro apps. If I look in the system event log I see errors like this: *Activation of application winstore_cw5n1h2txyewy!Windows.Store failed with error: This application does not support the contract specified or is not installed. See the Microsoft-Windows-TWinUI/Operational log for additional information.* In addition the tiles in metro have a small cross icon on them: I suspect that my Live ID (which I somehow managed to skip during update) is not set properly and consequently none of the online stuff works. But how do I fix this? I can't start PC settings, I can't start store. I see no way in the classic desktop of setting these things. I don't want to have to reinstall for this. Is there a simple fix?

    Read the article

  • Always use one slow connection in preference of a "faster" one

    - by billc.cn
    In Windows, there's this automatic metric thing where the metric is selected according to the declared speed of the link. I now have a gigabit LAN routed to a 2MB DSL service and a HSDPA mobile broadband connection. The former is always chosen for Internet packets even though the latter is actually faster. I tried setting the mobile broadband's interface metric to 1 and raising its priority in the advanced settings of the adapter settings, but this does not seem to affect the metric of the default route. The default route to the Ethernet interface always have a lower metric than the mobile broadband interface. Am I missing something here?

    Read the article

  • Why does my DNS change (and break) at regular intervals?

    - by Peter Kelly
    I have a laptop running Windows 7. Up until recently, everything was fine. We have multiple devices in my house connecting to the one access point with no problems. No issues with ISP. Now my Windows 7 PC DNS settings change every minute or so. Before the problem occurs if I do an ipconfig /all I have two DNS settings (primary/secondary) and everything is fine. After a short period of time this change to a sole DNS, 10.0.0.1. Webpages no longer resolve. If I do an ipconfig /renew, this fixes the problem. I have tried uninstalling various programs I thought might be related but the problem persists. Any ideas of potential causes?

    Read the article

  • Setting up VM server access via host MacBook Pro's WiFi hotspot

    - by user7609
    I have a virtual machine (VM) hosted on a MacBook Pro (MBP). There is a server installed on the VM. I'm trying to make this server accessible via MBP's WiFi hotspot so I can see it from my iPhone when connected to the hotspot. The VM is Parallels (latest version) and its OS is Win7 and the MBP is 2013 with Mavericks. With default settings and no hotspot enabled I can access the VM's server from the host OSX. The network setting on the VM is "Shared" and it's IP is 10.211.x.x. When I join the hotspot from another laptop the other laptop gets an IP 169.254.x.x and it can't ping 10.211.x.x or access the server on that VM Is there a combination of settings on the VM and MBP's hotspot such that I can access the VM server from a client on the MPB's hotspot?

    Read the article

  • Connecting FreeNAS 8 to Mac OS X Lion LDAP Server

    - by Absolution
    I currently have Mac OS X Lion Server running from a MacMini and want to use it purely as an LDAP server for authentication for FreeNAS 8. I have FreeNAS setup and running on a VM, all features working correctly and as expected however I cannot connect to my LDAP server (MacMini). Error message; **Nss_ldap: could not search LDAP server – server is unavailable** For LDAP service settings in FreeNAS, I know my Hostname and Base DN are correct (exact copies of what I set originally and ones that are shown in server:open directory overview) however I am unsure what to enter for Root bind DN, password and Suffix’s. I have researched into where I can find these out and other than following the FreeNAS examples it appears there is a way to find out within the Server Workgroup Manager specific to my settings – however this function is unavailable to me and cannot be ‘ticked’ to view for some strange reason. Some forums explain how Root bind DN should be uid=admin, dc=… and others cn=admin, dc=… – I’m rather confused and would appreciate your help or advice with this.

    Read the article

  • Group Policy for IE Security Zones

    - by Doug Luxem
    We are currently using the following Group Policy to control the Internet Explorer security zones: User Configuration\Administrative Templates\Windows Components\Internet Explorer\Internet Control Panel\Security Page Then setting the Site to Zone Assignment List with the various values using the following chart: Value Setting ------------------------------ 0 My Computer 1 Local Intranet Zone 2 Trusted sites Zone 3 Internet Zone 4 Restricted Sites Zone This works well; however, users are then unable to edit (or especially add) to their zone settings. Is there a way to lock in our custom zone settings while still giving users the ability to add their own sites to the security zones? Yes, I do realize the slight security risk in opening this up.

    Read the article

  • Accept incoming L2TP connections on Windows 7

    - by Greg
    Windows 2003 can be configured as a VPN server that uses L2TP with a preshared key. Windows 7 can be configured to accept incoming VPN connections, presumably using PPTP. Is there a way to configure Windows 7 to accept incoming L2TP connections? The configuration settings for incoming connections is extremely sparse; I don't see any place to enter a preshared key or specify the protocol to use. Perhaps it is beyond the capabilities of Win 7, but I hold out hope that I'm overlooking some Group Policy settings or registry edits that allow it.

    Read the article

  • IP camera's multicast/RTSP conflicting with 2.4GHz Wi-Fi?

    - by jayson
    Here at our business we have a Netgear R7000 running DD-WRT. I have been slowly adding IP cameras which I run using Blue Iris software. The last camera I bought (which is NOT a wireless camera), when I plug it into the network I start having really bad connection issues on the 2.4GHz Wi-Fi network. The 5GHz works fine, just the 2.4GHz all of the sudden has trouble connecting, as if it's conflicting. I've tried playing with the camera settings, different IP addresses, HTTP ports, etc, and discovered it to be a conflict with multicast. When multicast is checked, the Wi-Fi has issues but my video streams via Blue Iris. When unchecked, Wi-Fi works fine but the video won't stream through Blue Iris. The problem is there are no settings in the camera to change the RTSP port, which is set to 34567. Does anyone know something that could fix this issue? It all seems very strange to me but maybe someone has an idea?

    Read the article

  • Deny users in a certain group access to dovecot

    - by celil
    I installed the dovecot-imapd package in Ubuntu, and my setup is as follows: $ sudo dovecot -n # 1.2.9: /etc/dovecot/dovecot.conf # OS: Linux 2.6.32-27-generic-pae i686 Ubuntu 10.04.1 LTS log_timestamp: %Y-%m-%d %H:%M:%S protocols: imaps login_dir: /var/run/dovecot/login login_executable: /usr/lib/dovecot/imap-login mail_privileged_group: mail mail_location: maildir:~/Maildir mbox_write_locks: fcntl dotlock auth default: passdb: driver: pam userdb: driver: passwd For security reasons I would like to deny all users that are in the admin group ability to do imap login via dovecot. This is done in order to prevent a brute force attacker from discovering the admin passwords, and obtaining administrator privileges on the system. How can this be achieved? Presumably, I will have to modify some settings in /etc/dovecot/dovecot.conf, but I am hesitant to change the default settings lest I create other security vulnerabilities.

    Read the article

  • Only One GPU Detected in the Nvidia Quadra NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • Which GPO is making my Domain Controller my clients' DNS server?

    - by Harry Muscle
    I maintain a small domain (about 20 clients) and we need to make some changes to the DNS server that's being used by the clients. All the clients have been hard coded to use the domain controller as their DNS. Since these are new machines, and I never changed their DNS settings, I'm guessing there must be a GPO that's causing them to use the domain controller as their DNS. Since we don't have any GPO other than the default one yet, it's got to be the default GPO, however, I have looked through all the GPO settings and none of them refer to anything related to DNS. So I'm wondering if there's anything else that might be causing this. Any help or advice is highly appreciated. Thanks, Harry

    Read the article

  • Modifying %HOME% on Emacs 24.3 on Windows causes .emacs to not be found

    - by David
    In order for magit to read my git settings on Emacs 24.3.1 for Windows, I added the following configuration from a stack overflow post: (when (string-equal system-type "windows-nt") (setenv "HOME" (concat (getenv "HOMEDRIVE") (getenv "HOMEPATH"))) Interestingly, after this is added to my .emacs, Emacs thinks .emacs doesn't exist anymore. If I do M-x cd to ~ and then do M-x pwd it says ~ is located at C:\Users\Me\AppData\Roaming. It appears that emacs is reading the .emacs settings file because it loads my custom theme. However, if I try to find ~/.emacs Emacs doesn't see it. The file has all permissions on the file system for any user.

    Read the article

  • microsoft mouse and keyboard center doesn't show my mouse

    - by Andy
    as part of a recent windows update, the irritating and intrusive intellipoint microsoft mouse software now seems to have been replaced by the even more irritating and intrusive "microsoft mouse and keyboard center[sic]" I am left handed and need to switch the left and right mouse buttons round. the option to do this has disappeared from the mouse control panel, to be replaced by a link which opens up said mouse and keyboard center. this in turn is a window which allows me to change settings on the keyboard but does not have any way to control mouse settings any hints would be very welcome. this is driving me nuts.

    Read the article

  • Transmission-daemon not picking up on watch directory

    - by Mild Fuzz
    Trying to get my transmission-daemon to pick up files from a dropbox folder, to make remote starting easier (it's a headless system). As far as I can tell, the settings.json file is as expected, but none of the files I place in the folder get picked up. I have checked that dropbox is syncing correctly. Here is the whole settings.json file, but the relevant lines are included below: "watch-dir": "/home/john/Dropbox/torrents", "watch-dir-enabled": true Update It appears to be a permissions issue. From /var/log/syslog: Unable to watch "/home/john/Dropbox/torrents": Permission denied (watch.c:79) I have tried stopping the daemon - sudo service transmission-daemon stop - changing permissions of folder using chown - sudo chown -R john /home/john/Dropbox/torrents - restarting daemon - sudo service transmission-daemon start Same result, however Update 2 Permissions for the folder are: drwsrwsrwx 2 john debian-transmission 4096 2012-04-09 19:40

    Read the article

  • HP Proliant ML115 G5 - Boot order lost after reboot

    - by Filipe YaBa Polido
    I have one HP Proliant ML 115 G5 (AMD) with the latest BIOS (07-06-2009) and recently I've installed an USB disk. This is a common problem on old Proliant servers. When you plug the USB disk, BIOS boot order changes and tries to boot via USB. So, I'll change the BIOS settings and make the SATA disk the default boot device. The problem is, when I need to unplug the usb disk, and plug it again later. I can't be always changing the BIOS settings... How can one solve this for ever?!?!

    Read the article

  • Authorization error when testing FTP to UNC

    - by user64204
    We have a Windows Server 2008 R2 with Active Directory (hereafter called DC) running as a domain controller on which we have IIS and an FTP site installed. We have a second Server 2008 (hereafter called SHARE) which is joined to that domain and has a disk shared as a network share (\\share\Office). That network share is used as the ftp's physical path on DC. We've tested the FTP from the IIS FTP configuration panel, by clicking on Basic Settings... then Test Settings.... When setting Administrator as a username with the Connect as... option, everything is fine: When no user is provided we can the below error: Q1: Could someone explain in more understandable terms what is written in the Details text area?

    Read the article

  • How to invalidate nginx reverse proxy cache in front of other nginx servers?

    - by Olivier Lance
    I'm running a Proxmox server on a single IP address, that will dispatch HTTP requests to containers depending on the requested host. I am using nginx on the Proxmox side to listen to HTTP requests and I am using the proxy_pass directive in my different server blocks to dispatch requests according to the server_name. My containers run on Ubuntu and are also running a nginx instance. I'm having troubles with caching on a particular website that is fully static: nginx keeps on serving me stale content after files updates, until I: Clear /var/cache/nginx/ and restart nginx or set proxy_cache off for this server and reload the config Here's the detail of my configuration: On the server (proxmox): /etc/nginx/nginx.conf: user www-data; worker_processes 8; pid /var/run/nginx.pid; events { worker_connections 768; # multi_accept on; use epoll; } http { ## # Basic Settings ## sendfile on; #tcp_nopush on; tcp_nodelay on; #keepalive_timeout 65; types_hash_max_size 2048; server_tokens off; # server_names_hash_bucket_size 64; # server_name_in_redirect off; include /etc/nginx/mime.types; default_type application/octet-stream; client_body_buffer_size 1k; client_max_body_size 8m; large_client_header_buffers 1 1K; ignore_invalid_headers on; client_body_timeout 5; client_header_timeout 5; keepalive_timeout 5 5; send_timeout 5; server_name_in_redirect off; ## # Logging Settings ## access_log /var/log/nginx/access.log; error_log /var/log/nginx/error.log; ## # Gzip Settings ## gzip on; gzip_disable "MSIE [1-6]\.(?!.*SV1)"; gzip_vary on; gzip_proxied any; gzip_comp_level 6; # gzip_buffers 16 8k; gzip_http_version 1.1; gzip_types text/plain text/css application/json application/x-javascript text/xml application/xml application/xml+rss text/javascript; limit_conn_zone $binary_remote_addr zone=gulag:1m; limit_conn gulag 50; ## # Virtual Host Configs ## include /etc/nginx/conf.d/*.conf; include /etc/nginx/sites-enabled/*; } /etc/nginx/conf.d/proxy.conf: proxy_redirect off; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_hide_header X-Powered-By; proxy_intercept_errors on; proxy_buffering on; proxy_cache_key "$scheme://$host$request_uri"; proxy_cache_path /var/cache/nginx levels=1:2 keys_zone=cache:10m inactive=7d max_size=700m; /etc/nginx/sites-available/my-domain.conf: server { listen 80; server_name .my-domain.com; access_log off; location / { proxy_pass http://my-domain.local:80/; proxy_cache cache; proxy_cache_valid 12h; expires 30d; proxy_cache_use_stale error timeout invalid_header updating; } } On the container (my-domain.local): nginx.conf: (everything is inside the main config file -- it's been done quickly...) user www-data; worker_processes 1; error_log logs/error.log; events { worker_connections 1024; } http { include mime.types; default_type application/octet-stream; sendfile on; #tcp_nopush on; keepalive_timeout 65; gzip off; server { listen 80; server_name .my-domain.com; root /var/www; access_log logs/host.access.log; } } I've read many blog posts and answers before resolving to posting my own questions... most answers I can see suggest setting sendfile off; but that didn't work for me. I have tried many other things, double checked my settings and all seems fine. So I'm wondering whether I am not expecting nginx's cache to do something it's not meant to...? Basically, I thought that if one of my static files in my container was updated, the cache in my reverse proxy would be invalidated and my browser would get the new version of the file when it requests it... But I now have the sentiment I misunderstood many things. Of all things, I now wonder how nginx on the server can know about a file in the container has changed? I have seen a directive proxy_header_pass (or something alike), should I use this to let the nginx instance from the container somehow inform the one in Proxmox about updated files? Is this expectation just a dream, or can I do it with nginx on my current architecture?

    Read the article

  • Disabling networkmanager for a specific interface

    - by bdonlan
    I'd like to do some experimentation with hostap without disabling my primary wireless interface. How do I tell networkmanager to keep its hands off a specific interface or interfaces while allowing it to continue managing all other interfaces normally? I'm using Ubuntu 9.04. (Wasn't sure if this should go on superuser or serverfault, as networkmanager isn't much of a 'server' tool - if it belongs on serverfault please feel free to move it) Edit: I've tried adding this to /etc/network/interfaces: allow-hotplug wlan2 iface wlan2 inet static address 192.168.49.1 netmask 255.255.255.0 But this has no apparent effect, even after restarting NetworkManager. Here's my /etc/NetworkManager/nm-system-settings.conf: [main] plugins=ifupdown,keyfile [ifupdown] managed=false Edit[2]: Looks like I needed to restart nm-system-settings, then NetworkManager.

    Read the article

  • Dell Latitude E4300 TouchPad - Odd Behavior

    - by Cade Roux
    I'm seeing some intermittent behavior on the touchpad. First it wasn't working at all. Then during restart, for a little while it seemed like the buttons attached to the joystick and external mouse were both swapped left/right. Then I went in to the dell touchpad control and disabled the touchpad and re-enabled it and nothing happened. Then a short while after disabling the joystick the touch pad started working. So I restarted to see if it would keep the settings and before login, the touchpad appeared to work, then after login it stopped working for a few minutes while login continued. Then after the login was almost completed it started to work again. It appeared to have retained the settings for the disabled joystick. It seems like perhaps there are conflicting mouse drivers trying to simultaneously or similar. This doesn't seem normal for the touchpad to be disabled for so long after login. What steps should I take to ensure the drivers are right?

    Read the article

  • Can't install Nuget or other extension to VS2012 on Win8

    - by VinnyG
    When I try to install any extension for visual studio ultimate 2012 on my new installation of Winodws 8 I get this exception : System.IO.FileNotFoundException: The system cannot find the file specified. (Exception from HRESULT: 0x80070002) at System.Runtime.InteropServices.Marshal.ThrowExceptionForHRInternal(Int32 errorCode, IntPtr errorInfo) at Microsoft.VisualStudio.Settings.ExternalSettingsManager.GetScopePaths(String applicationPath, String suffixOrName, String vsVersion, Boolean isLogged, Boolean isForIsolatedApplication) at Microsoft.VisualStudio.Settings.ExternalSettingsManager.CreateForApplication(String applicationPath) at VSIXInstaller.App.GetExtensionManager(SupportedVSSKU sku) at VSIXInstaller.App.GetExtensionManagerForApplicableSKU(SupportedVSSKU supportedSKU, IInstallableExtension installableExtension, List`1 applicableSKUs) at VSIXInstaller.App.InitializeInstall() at System.Threading.Tasks.Task.InnerInvoke() at System.Threading.Tasks.Task.Execute() I tryed to repair VS, did not work, and also try to uninstall/install and got the same problem. Anybody as an idea?

    Read the article

  • A "region code" restriction for a custom created video dvd file

    - by user180820
    I want to create a video dvd ( no menus, just "plug and play" ) from a few video files. I`m doing it like this: ffmpeg -i sample-media/hellboy-2.wmv -y -target ntsc-dvd sample-media-to-mpeg/hellboy-2.vob dvdauthor -o sample-dvd -x dvdauthor-settings.xml mkisofs -dvd-video -o hellboy-2-trailers.iso sample-dvd/ where "dvdauthor-settings.xml" is: link. But when I try to play the iso file in windows it says: Windows Media Player cannot play the DVD because the disc prohibits playback in your region of the world. You must obtain a disc that is intended for your geographic region. When I open the *.IFO file with IfoEdit it says that all world regions are unabled. Can someone tell me why is this happening? ( maybe the whole process of creating the *.iso file is wrong? )

    Read the article

  • Why do I have to manually 'Restart Management Network' on vSphere 5 host after reboot to get networking available?

    - by growse
    I've got a couple of vSphere 5.0 hosts in a small lab environment here and I've noticed a strange behaviour. When on of the hosts gets rebooted, it is unresponsive to the network until I log into the ESX console, Press F2 to customize and select Restart management network. Once this is done, the networking works perfectly as expected. Each host has two NICs which are trunked together using Etherchannel to a Cisco 3750. The link is also a .1q VLAN trunk and the management network is configured on VLAN121 with the VM traffic configured on VLAN118. Why would the host be completely dead to the world until I physically kick it? Edit Sample switch config for trunk: interface Port-channel2 description Blade 1 EtherChannel Trunk switchport trunk encapsulation dot1q switchport mode trunk end ! ! interface GigabitEthernet4/0/1 description Bladecenter1 CPM 1A switchport trunk encapsulation dot1q switchport mode trunk speed 1000 duplex full channel-group 2 mode on end Vswitch teaming settings: Management port group settings:

    Read the article

  • Chassis fans and power LEDs still work in Hibernate

    - by Jaded
    I have ASRock Z68 Extreme3 Gen3 motherboard recently updated to 2.20 BIOS version. OS is Windows 7 x64. The problem is after that update full hibernation (by that i mean full system power off) stopped working although everything was fine before. Now when I press hibernate, sleep in initiated as usual, monitor goes to sleep, HDD and CPU fan stop spinning, but chassis fans (i have Gigabyte Aurora 3D 570 case with two rear and one front fans) still remain working. Also power leds are lit as if computer is turned on. Tried changing different UEFI settings related to sleep mode, and none of them change above described behaviour. I have "Deep Sleep" (Advanced-South Bridge Configuration) set to "Enabled in S4-S5", "Suspend to RAM" (Advanced-ACPI Configuration) set to "Auto", all fans settings in "H/W Monitor" set to "Auto".

    Read the article