Search Results

Search found 6711 results on 269 pages for 'generic noob'.

Page 137/269 | < Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >

  • concatenate rows of Clob with plsql

    - by david K
    Hi, late considere i conider if got a table who got an Id and a clob content like: create table v_EXAMPLE_L ( nip number, xmlcontent clob ); we insert our data: Insert into V_EXAMPLE_L (NIP,XMLCONTENT) values (17852,'delta548484646846484'); Insert into V_EXAMPLE_L (NIP,XMLCONTENT) values (17852,'omega545648468484'); Insert into V_EXAMPLE_L (NIP,XMLCONTENT) values (17852, 'gamma54564846qsdqsdqsdqsd8484'); i'm trying do do a function that concatenate the rows of the clob that gone be the result of a select , i mean without having to give multiple parameter about the name of table or such , i should only give here the column that contain the clobs , and she should handle the rest!. CREATE OR REPLACE function assemble_clob(q varchar2) return clob is v_clob clob; tmp_lob clob; hold VARCHAR2(4000); --cursor c2 is select xmlcontent from V_EXAMPLE_L where id=17852 cur sys_refcursor; begin OPEN cur FOR q; LOOP FETCH cur INTO tmp_lob; EXIT WHEN cur%NOTFOUND; --v_clob := v_clob || XMLTYPE.getClobVal(tmp_lob.xmlcontent); v_clob := v_clob || tmp_lob; END LOOP; return (v_clob); --return (dbms_xmlquery.getXml( dbms_xmlquery.set_context("Select 1 from dual")) ) end assemble_clob; the function is broken ... (if anybody could give me a help, thanks a lot, and i'm noob in sql so ....). and thanks

    Read the article

  • Reading binary data from serial port using Dejan TComport Delphi component

    - by johnma
    Apologies for this question but I am a bit of a noob with Delphi. I am using Dejan TComport component to get data from a serial port. A box of equipment connected to the port sends about 100 bytes of binary data to the serial port. What I want to do is extract the bytes as numerical values into an array so that I can perform calculations on them. TComport has a method Read(buffer,Count) which reads DATA from input buffer. function Read(var Buffer; Count: Integer): Integer; The help says the Buffer variable must be large enough to hold Count bytes but does not provide any example of how to use this function. I can see that the Count variable holds the number of bytes received but I can't find a way to access the bytes in Buffer. TComport also has a methord Readstr which reads data from input buffer into a STRING variable. function ReadStr(var Str: String; Count: Integer): Integer; Again the Count variable shows the number of bytes received and I can use Memo1.Text:=str to display some information but obviously Memo1 has problems displaying the control characters. I have tried various ways to try and extract the byte data from Str but so far without success. I am sure it must be easy. Here's hoping.

    Read the article

  • Way to access Palm Zlib DB files (.pdb) on Windows or Debian

    - by Italy Kafe
    Is anyone aware of a way to access the data in zlib database files for Palm? The file extension is .pdb, but that extension covers a whole range of formats, so a generic 'pdb viewer' won't necessarily be able to handle this. I'd like to be able to open pdb zlib database files. I'd be grateful for any access method: an app for Windows or Debian, or a library for Python or PHP that makes it possible to access the data in these files. If no such tool exists, does anyone know how to use zlib to decompress the data from such a Palm pdb database?

    Read the article

  • How does one get Vista to display .MOV thumbnails as a frame from the movie?

    - by Paul Hollingsworth
    I've discovered that Windows Vista explorer shell does not display proper "thumbnail"s for .MOV files. e.g. For .JPG files, the explorer shell, when in Thumbnail mode, displays a scaled down version of the image. But for .MOV files, it displays the same icon as in the non-thumbnail view, which is just some generic thing that shows you it's going to be played with Quicktime or whatever. What XP used to do was show you a frame from the actual movie as the thumbnail. I've looked on internet and found various proposed solutions, but none which actually work. Is there a simple step-by-step process for getting Vista to properly display thumbnails for .MOV files?

    Read the article

  • JQuery fadeIn() moving other CSS elements on fadeIn()

    - by Infiniti Fizz
    Hi, I've just been learning some jQUery to get a basic image gallery going on a website I'm creating for a hotel but it's currently not going to plan. I've got it so the arrows will cycle through images (no animation yet) but I decided that the arrows should fade in when the image is hovered over and fade out when not but this is messing up the CSS somehow. The arrows start faded out by calling: $('.arrowRight').fadeOut(0);$('.arrowLeft').fadeOut(0); at the start of the jQuery ready() function. This is fine, but when you hover over the image and the arrows fade in, the image shifts to the right and I don't know why. I suppose it could be because the left arrow now fading in means it is getting pushed over by it but the arrow has the following css: position:relative; top: -90px; left: 25px; Should a relative element be able to alter a normal element's position? If you need to try it out, just hover over the large (placeholder) image and they image will jump across when the arrows fade in and jump back when they fade out. Any ideas why this is happening? I'm a jQuery noob. Here is a link to the page: BeanSheaf Hotel Temporary Space Thanks for your time, InfinitiFizz

    Read the article

  • Flash CS3/AS3 - How to Mask Nested MovieClips in External Classes

    - by Max Jackson
    I have a number of external class files that make up (or are trying to build) a portfolio. One of the class files for this project is a Menu.as class I tried extends, but I'm yet to use extends to where it doesn't become a ball of tangled holiday cheer. So my main portfolio class (the one where I'm assembling everything) calls an instance of the Menu class. From the Preloader through the Portfolio class into the Menu class is where I'm passing the content because I want to package things properly. This is Menu content, so naturally I want to position it in a properly names spot. I'm trying to reveal this Menu in a mask and I'm getting the old #1009 error. In a trace, this will work: trace(site_mc.menu_mc.mainMask_mc); // returns [object mainMask_mc_4] However, when I try to truncate the string into a single compact_mc... compactMenu_mc = site_mc.menu_mc.mainMask_mc; trace(compact_mc); // it won't trace (#1009). I said to hell with it, but now I need to have one MovieClip mask another. So I figure I can't go all... parent.parent.parent.clip_mc.mask = parent.parent.parent.masked_mc Probably because of datatyping and whatever else. I hate to be vague, but I'm new and have been working like gangbusters for days to get this portfolio up. Any suggestions or pointers on things my noob brain might've missed are given much thanks. :)

    Read the article

  • How to ensure full path in Windows batch FOR loop

    - by palswim
    I've created a generic batch (or Windows Command) file that lets me loop through the contents of a directory and call a command for each item. IF a%1==a ( set _DIR="%CD%") ELSE ( set _DIR="%~1") IF a%2==a ( set _COMMAND=rem) ELSE ( set _COMMAND=%2) IF a%3==a ( set _FILTER=*.*) ELSE ( set _FILTER=%3) set _OPTS=%4 FOR /F "delims=" %%f IN ('dir %_DIR%\%_FILTER% %_OPTS% /b') DO ( %_COMMAND% "%%f" ) But, I'm trying to determine how to ensure that I call %_COMMAND% on the correct file. I've tried pre-pending the directory variable onto the front, like %_COMMAND% %_DIR%\"%%f", but this leaves a quotation mark in the parameter I pass. For example, if I call my batch file exec_dir.bat, and call it with the following echo_test.bat, I see that all of the files have a quotation mark when echo_test.bat runs. echo %~dpn1.mp4 That batch script produces: > exec_dir.bat "C:\Users\User\Desktop\Test Folder" echo_test.bat *.txt C:\Users\User\Desktop\Test Folder\"Test File.txt C:\Users\User\Desktop\Test Folder\"Test2.txt My thought is that it has something to do with the \ as an escape character, but I can't seem to work around it.

    Read the article

  • VGA cable causing resolution issue

    - by LatishS
    I recently bought a new VGA cable. When connected, Windows 7 detects my monitor as a generic plug and play monitor. The resolution goes bad with the screen blurred. This problem disappears when I connect my original VGA cable. Also Windows 7 detects my LG monitor correctly in this case. I am pretty sure it is something to do with the VGA cable but have no idea what could be the possible issue. Any pointers would be very much appreciated.

    Read the article

  • Why is this LTO4 Tape-drive not working

    - by Tim Haegele
    # modprobe mptsas # dmesg [ 4274.796796] scsi target7:0:0: mptsas: ioc1: delete device: fw_channel 0, fw_id 0, phy 0, sas_addr 0x50050763124b29ac [ 4274.939579] mptsas 0000:01:00.0: PCI INT A disabled [ 4280.934531] Fusion MPT SAS Host driver 3.04.12 [ 4280.934552] mptsas 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 4280.934692] mptbase: ioc2: Initiating bringup [ 4281.490183] ioc2: LSISAS1064E B3: Capabilities={Initiator} [ 4281.490203] mptsas 0000:01:00.0: setting latency timer to 64 [ 4293.555274] scsi8 : ioc2: LSISAS1064E B3, FwRev=011e0000h, Ports=1, MaxQ=277, IRQ=16 [ 4293.574906] mptsas: ioc2: attaching ssp device: fw_channel 0, fw_id 0, phy 0, sas_addr 0x50050763124b29ac [ 4293.576471] scsi 8:0:0:0: Sequential-Access IBM ULTRIUM-HH4 B6W1 PQ: 0 ANSI: 6 [ 4293.578549] st 8:0:0:0: Attached scsi tape st0 [ 4293.578550] st 8:0:0:0: st0: try direct i/o: yes (alignment 512 B) [ 4293.578577] st 8:0:0:0: Attached scsi generic sg5 type 1 # mt -f /dev/st0 status mt -f /dev/st0 status mt: /dev/st0: rmtopen failed: Input/output error # dd if=/dev/zero of=/dev/nst0 bs=1024 count=10 dd: opening `/dev/nst0': Input/output error I am running debian squeeze 2.6.32-5-amd64 #1 SMP Sun May 6 04:00:17 UTC 2012 x86_64 GNU/Linux Server is Fujitsu TX140 with Controller Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS Tape+Hardware is new.

    Read the article

  • C++: Declaration of template class member specialization

    - by Ziv
    When I specialize a (static) member function/constant in a template class, I'm confused as to where the declaration is meant to go. Here's an example of what I what to do - yoinked directly from IBM's reference on template specialization: ===IBM Member Specialization Example=== template<class T> class X { public: static T v; static void f(T); }; template<class T> T X<T>::v = 0; template<class T> void X<T>::f(T arg) { v = arg; } template<> char* X<char*>::v = "Hello"; template<> void X<float>::f(float arg) { v = arg * 2; } int main() { X<char*> a, b; X<float> c; c.f(10); // X<float>::v now set to 20 } The question is, how do I divide this into header/cpp files? The generic implementation is obviously in the header, but what about the specialization? It can't go in the header file, because it's concrete, leading to multiple definition. But if it goes into the .cpp file, is code which calls X::f() aware of the specialization, or might it rely on the generic X::f()? So far I've got the specialization in the .cpp only, with no declaration in the header. I'm not having trouble compiling or even running my code (on gcc, don't remember the version at the moment), and it behaves as expected - recognizing the specialization. But A) I'm not sure this is correct, and I'd like to know what is, and B) my Doxygen documentation comes out wonky and very misleading (more on that in a moment a later question). What seems most natural to me would be something like this, declaring the specialization in the header and defining it in the .cpp: ===XClass.hpp=== #ifndef XCLASS_HPP #define XCLASS_HPP template<class T> class X { public: static T v; static void f(T); }; template<class T> T X<T>::v = 0; template<class T> void X<T>::f(T arg) { v = arg; } /* declaration of specialized functions */ template<> char* X<char*>::v; template<> void X<float>::f(float arg); #endif ===XClass.cpp=== #include <XClass.hpp> /* concrete implementation of specialized functions */ template<> char* X<char*>::v = "Hello"; template<> void X<float>::f(float arg) { v = arg * 2; } ...but I have no idea if this is correct. Any ideas? Thanks much, Ziv

    Read the article

  • WinXP How to Tunnel LPT over USB

    - by Michael Pruitt
    I have a windows program that accesses a device connected to a LPT (1-3) 25 pin port. The communication is bidirectional, and I suspected the control lines are also accessed directly. I would like to migrate the device to a machine that does not have a LPT port. I saw the dos2usb software, but that takes the output (from a DOS program) and 'prints' it formatted for a specific printer. I need a raw LPT connection, and a cable that provides access to all the control signals. I do have a USB to 36-pin Centronics that may have the extra signals. I use it with a vinyl cutter that doesn't like most of the USB dongles. It comes up as USB001. Would adding and sharing a generic printer, then mapping LPT1 to the share get me closer? Would that work for a parallel port scanner? My preferred solution is a USB cable with a driver that will map it to LPT1, LPT2, or LPT3.

    Read the article

  • USB to LPT adapter?

    - by Dave
    I'm bummed out, pretty much all of our computers here lack parallel ports. I have an EETools ChipMax programming tool that has one of the old-school Centronics connectors on the back. I figured that someone must make a USB to LPT adapter. Sure enough, I found one from iogear, the GUC1284B that is a USB to Parallel Printer cable. Note the boldface on the Printer. It must connect to a printer -- it isn't some generic USB to parallel interface, unfortunately. Does anyone here know of an adapter that works for parallel devices that aren't printers? I'd hate to have to buy a USB version of the ChipMax when I don't need to use it very much.

    Read the article

  • Continuing permissions issues - ASP.net, IIS 7, Server 2008 - 0x80070005 (http 500.19) error

    - by Re-Pieper
    I created an ASP.net MVC developed web application and I am trying to set up IIS. The Error: Http error 500.19, error code 0x80070005, Cannot read configuration file due to insufficient permissions, config file: C:\inetpub\wwwroot\BudgetManagerMain\BudgetManager\web.config If I set the AppPool to use 'administrator' i have no problems and can access the site just fine. If i set to NETWORK SERVICE (or anything else including self-created admin or non-admin user accounts), i get the above error. Things I have tried: identity for Application pool named 'test' is 'NetworkService' Set full access privs for wwwroot and all children files/folders verified effective permissions and NETWORK SERVICE has full access. Authentication on my site is set for anonymous and running under Application Pool Identity I do not have any physical path credentials set on the website confirmed website is set to run under the application pool named 'test' using Process Monitor, here is a summary of what i found on the ACCESS DENIED event EVENT TAB: Class: File System Operation: CreateFile Result: Access Denied Path: ..\web.config Desired Access: Generic Read Disposition: Open Options: Sybnchronous IO Non-Alert, Non-Directory file Attributes: N ShareMode: Read AllocaitonSize: n/a PROCESS TAB ...lots of stuff that seems irrelevant User: NT AUTHORITY\NETWORK SERVICE

    Read the article

  • How to host multiple mail domains with courier?

    - by Dave Vogt
    I had my server set up with generic aliases in /etc/courier/aliases/users, which worked fine. But today I wanted to host some new domains, where addresses overlap. What I need is that [email protected] goes to account "dv", but [email protected] goes to account "d2". So I set up a new file containing fully qualified addresses ([email protected]: dv) instead of the previous dave: dv. But somehow, courier-smtpd doesn't accept mail to these addresses anymore. makealiases -dump prints all the aliases the way they should be.. so i'm a bit stuck.

    Read the article

  • tcpdump filter that excludes private ip traffic

    - by Kyle Brandt
    For a generic filter to exclude all traffic in my dump that is between private IP address, I came up with the following: sudo tcpdump -n ' (not ( (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) and (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) ) ) and (not ( (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) and (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) ) )' -w test2.dump Seems pretty excessive, but it also seems to work, is this filter a lot longer than it needs to be and there is better way to express this logic, or is there anything wrong with the filter?

    Read the article

  • rails use counts in diferent views

    - by Oluf Nielsen
    Hello i guess this is going to be pretty noob question.. But.. I have an scaffold called list, which has_many :wishes. And with that information in my model, I can in my list view use this code <%=h @list.wishes.count % well now I have made an controller called statusboard.. And in that' I have 3 functions.. Or how to say it.. but it is Index, loggedin, loggedout.. And .. In loggedin and in the file #app/views/statusboard/loggedin.html.erb i want to display this.. Howdy {Username}, you have made {count lists} lists, and {count wishes} wishes here is that i figured i should write in my file.. Howdy {Username}, you have made <%=h @user.list.count % lists, and <%=h @user.wishes.count % wishes my list model is like this = class List < ActiveRecord::Base   attr_accessible :user_id, :name, :description   belongs_to :users   has_many :wishes end and my wish model is like this = class Wish < ActiveRecord::Base   attr_accessible :list_id, :name, :price, :link, :rating, :comment   belongs_to :list end and last my user model is like this = class User < ActiveRecord::Base   # Include default devise modules. Others available are:   # :token_authenticatable, :lockable and :timeoutable   devise :database_authenticatable, :registerable,# :confirmable,              :recoverable, :rememberable, :trackable, :validatable   # Setup accessible (or protected) attributes for your model   attr_accessible :email, :password, :password_confirmation   has_many :lists end i hope someone can help me :-)! / Oluf Nielsen

    Read the article

  • samba not starting on ubuntu

    - by Mirage
    I have this output user123@Matrix-Server:~$ /etc/init.d/samba stop bash: /etc/init.d/samba: No such file or directory sputnik@Matrix-Server:~$ sudo /etc/init.d/samba restart sudo: /etc/init.d/samba: command not found user123@Matrix-Server:~$ user123@Matrix-Server:~$ sudo apt-get install samba smbfs Reading package lists... Done Building dependency tree Reading state information... Done samba is already the newest version. smbfs is already the newest version. The following packages were automatically installed and are no longer required: linux-headers-2.6.32-19-generic linux-headers-2.6.32-19 Use 'apt-get autoremove' to remove them. 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded.

    Read the article

  • Unity The parameter host could not be resolved when attempting to call constructor

    - by Terrance
    When I attempt to instantiate my instance of the base class I get the error: a ResolutionFailedException with roughly the following error "The parameter host could not be resolved when attempting to call constructor" I'm currently not using an Interface for the base type and my instance of the class is inheriting the base type class. I'm new to Unity and DI so I'm thinking its something I forgot possibly. ExeConfigurationFileMap map = new ExeConfigurationFileMap(); map.ExeConfigFilename = "Unity.Config"; Configuration config = ConfigurationManager.OpenMappedExeConfiguration(map, ConfigurationUserLevel.None); UnityConfigurationSection section = (UnityConfigurationSection)config.GetSection("unity"); IUnityContainer container = new UnityContainer(); section.Containers.Default.Configure(container); //Throws exception here on this BaseCalculatorServer server = container.Resolve<BaseCalculatorServer>(); and the Unity.Config file <container> <types> <type name ="CalculatorServer" type="Calculator.Logic.BaseCalculatorServer, Calculator.Logic" mapTo="Calculator.Logic.CalculateApi, Calculator.Logic"/> </types> </container> </containers> The Base class using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.Runtime.Serialization; using System.ServiceModel; using System.ServiceModel.Transactions; using Microsoft.Practices.Unity; using Calculator.Logic; namespace Calculator.Logic { public class BaseCalculatorServer : IDisposable { public BaseCalculatorServer(){} public CalculateDelegate Calculate { get; set; } public CalculationHistoryDelegate CalculationHistory { get; set; } /// <summary> /// Performs application-defined tasks associated with freeing, releasing, or resetting unmanaged resources. /// </summary> public void Dispose() { this.Dispose(); } } } The Implementation using System; using System.Collections.Generic; using System.Linq; using System.Text; using Calculator.Logic; using System.ServiceModel; using System.ServiceModel.Configuration; using Microsoft.Practices.Unity; namespace Calculator.Logic { public class CalculateApi:BaseCalculatorServer { public CalculateApi(ServiceHost host) { host.Open(); Console.WriteLine("Press Enter To Exit"); Console.ReadLine(); host.Close(); } public CalculateDelegate Calculate { get; set; } public CalculationHistoryDelegate CalculationHistory { get; set; } } } Yes both base class and implementation are in the same Namespace and thats something design wise that will change once I get this working. Oh and a more detailed error Resolution of the dependency failed, type = "Calculator.Logic.BaseCalculatorServer", name = "". Exception message is: The current build operation (build key Build Key[Calculator.Logic.BaseCalculatorServer, null]) failed: The value for the property "Calculate" could not be resolved. (Strategy type BuildPlanStrategy, index 3)

    Read the article

  • Javascript Print Script Not Working in IE

    - by TY
    Greets! I'm a noob struggling to learn html and javascript - getting there slowly. I'm trying to print a DIV served up by SimpleModal. The page is at: www.planetsarsfield.com This "Print" function is in the recipe box at the bottom. Everything works great in FF, but it doesn't work at all in IE8. I must be doing something fundamentally wrong but I can't spot it. Any ideas? Cheers, TY ++++++++++++++++++++++++++++++++++++++++++++++++ <script type="text/javascript"> function PrintElem(elem) { Popup($(elem).html()); } function Popup(data) { var mywindow = window.open('', 'basic-modal-content', 'height=400,width=600'); mywindow.document.write('<html><head><title>on the grill... latest recipe</title>'); mywindow.document.write('<link href="PATH/print.css" rel="stylesheet" type="text/css" />') mywindow.document.write('</head><body >'); mywindow.document.write(data); mywindow.document.write('</body></html>'); mywindow.document.close(); mywindow.print(); return true; } </script>

    Read the article

  • Delay between printing via lp in opensuse

    - by adamweeks
    I am experiencing a 10-15 second delay when printing multiple documents to a barcode printer in opensuse. I have had the same setup on other systems with older versions of opensuse without any issue. The setup is as follows: The print queue is setup as a "generic with driver Raw Queue". The files being sent down to the printers are simple text files with the lp command: lp -dprinter1 /path/file The printer is a JetDirect compatible device (Intermec brand) with a standard 9100 port socket setup. If I send a multi-page document to the printer, it will print nonstop the multiple pages. If I send 2 or more text files down via separate "lp" commands, the delay will be there between each printout. I've tried multiple different printers and they all experience the same issue.

    Read the article

  • SqlBulkCopy is slow, doesn't utilize full network speed

    - by Alex
    Hi, for that past couple of weeks I have been creating generic script that is able to copy databases. The goal is to be able to specify any database on some server and copy it to some other location, and it should only copy the specified content. The exact content to be copied over is specified in a configuration file. This script is going to be used on some 10 different databases and run weekly. And in the end we are copying only about 3%-20% of databases which are as large as 500GB. I have been using the SMO assemblies to achieve this. This is my first time working with SMO and it took a while to create generic way to copy the schema objects, filegroups ...etc. (Actually helped find some bad stored procs). Overall I have a working script which is lacking on performance (and at times times out) and was hoping you guys would be able to help. When executing the WriteToServer command to copy large amount of data ( 6GB) it reaches my timeout period of 1hr. Here is the core code for copying table data. The script is written in PowerShell. $query = ("SELECT * FROM $selectedTable " + $global:selectiveTables.Get_Item($selectedTable)).Trim() Write-LogOutput "Copying $selectedTable : '$query'" $cmd = New-Object Data.SqlClient.SqlCommand -argumentList $query, $source $cmd.CommandTimeout = 120; $bulkData = ([Data.SqlClient.SqlBulkCopy]$destination) $bulkData.DestinationTableName = $selectedTable; $bulkData.BulkCopyTimeout = $global:tableCopyDataTimeout # = 3600 $reader = $cmd.ExecuteReader(); $bulkData.WriteToServer($reader); # Takes forever here on large tables The source and target databases are located on different servers so I kept track of the network speed as well. The network utilization never went over 1% which was quite surprising to me. But when I just transfer some large files between the servers, the network utilization spikes up to 10%. I have tried setting the $bulkData.BatchSize to 5000 but nothing really changed. Increasing the BulkCopyTimeout to an even greater amount would only solve the timeout. I really would like to know why the network is not being used fully. Anyone else had this problem? Any suggestions on networking or bulk copy will be appreciated. And please let me know if you need more information. Thanks. UPDATE I have tweaked several options that increase the performance of SqlBulkCopy, such as setting the transaction logging to simple and providing a table lock to SqlBulkCopy instead of the default row lock. Also some tables are better optimized for certain batch sizes. Overall, the duration of the copy was decreased by some 15%. And what we will do is execute the copy of each database simultaneously on different servers. But I am still having a timeout issue when copying one of the databases. When copying one of the larger databases, there is a table for which I consistently get the following exception: System.Data.SqlClient.SqlException: Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding. It is thrown about 16 after it starts copying the table which is no where near my BulkCopyTimeout. Even though I get the exception that table is fully copied in the end. Also, if I truncate that table and restart my process for that table only, the tables is copied over without any issues. But going through the process of copying that entire database fails always for that one table. I have tried executing the entire process and reseting the connection before copying that faulty table, but it still errored out. My SqlBulkCopy and Reader are closed after each table. Any suggestions as to what else could be causing the script to fail at the point each time?

    Read the article

  • Nt4.0 Printer Driver not compatible with Vista?

    - by PhillC
    I've got a Brother Fax-8360P printer that has a standard printer port so it can be connected to my WindowsXP machine. I've found some drivers on the net that work and it is a pretty decent laser printer. However, when I try and connect up to it from my Vista machine over the network, it tells me that "The printer driver is not compatible with a policy enabled on your computer that blocks NT4.0 drivers". Main question - is it possible to alter this so that my Vista machine will allow me to print via the network. Secondary question - does anyone know of any generic driver that will work instead?

    Read the article

  • Where are my Tomcat Logs?

    - by gav
    Hi All, I installed Tomcat6 on a Ubuntu 9.04 server using apt-get install tomcat6. I uploaded a WAR using the manager interface and tried to start the application but get a pretty generic error on the Web interface saying it couldn't be started. I am trying to find the logs to determine why my war won't start (I suspect low memory as i'm on a small VPS) but I don't know where they are. /var/lib/tomcat6/logs is empty. My Tomcat splash page reliably informs me of the following; Tomcat is installed with CATALINA_HOME in /usr/share/tomcat6 CATALINA_BASE in /var/lib/tomcat6, following the rules from /usr/share/doc/tomcat6-common/RUNNING.txt.gz. Thanks, Gav

    Read the article

  • Linux: close a program with command line (not kill it)

    - by CodeNoob
    Some applications only allow one running instance (like eclipse, if you want to use the same workspace). So if I log in from another location, I have to kill/close the application that was open when I previously logged in from another location. I always use kill command to kill the running process. But, if you kill a process, it might not save some states that are useful for future usage. However, if you "close" it properly byclicking on the close button, for example, it will save the states properly. Is there a way to properly "close" an application from command line? I know this can vary from applications, so let's be a bit more generic: how to send a signal to another running application, and this signal works just as if we click the "close" button in the top bar? thanks!

    Read the article

  • Global hotkeys: songbird on KDE

    - by alpha1
    I'm running songbird on opensuse 11.2 KDE 4.3.1 on my EEE pc. On windows, there is a hotkey thing inside Songbird, so i set META F9,10,11,12 as media keys and it work just fine. On linux, there is not hotkey thing in songbird, and I would like to set those same hotkeys. I've played around with the Amarok Hotkeys, which are now setup that way, and looked in all the KDE shortcuts, but cannot find a way to add a new program and new hot keys. I know its possible, I did it before once, but the KDE shortcut programs have changed and I no longer see the stuff i used to do it before. I'd like to do the same to banshee at some point, but Songbird is the important program. Any Ideas? Any way to set those keys to generic media buttons?

    Read the article

< Previous Page | 133 134 135 136 137 138 139 140 141 142 143 144  | Next Page >