Search Results

Search found 30115 results on 1205 pages for 'read uncommitted'.

Page 143/1205 | < Previous Page | 139 140 141 142 143 144 145 146 147 148 149 150  | Next Page >

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • How to logon with local account? RODC "There are no logon servers to process your request"

    - by g18c
    I have a site-to-site VPN, writeable DC in main office, Read-only DC. Today the VPN went down, but i couldnt log in to the read-only DC - the error message came up There are no logon servers to process your request. Since the RODC is a domain controller, there is no local administrator. How can i ensure that i am always able to log on to the RODC with a known account in an emergency if the writeable DC is not available?

    Read the article

  • Problem reading hexadecimal buffer from C socket

    - by Olaseni
    I'm using the SDL_net sockets API to create a server and client. I can easily read a string buffer, but when I try to send hexadecimal data, recv gets the length, but I cannot seem to be a able to read the buffer contents. IPaddress ip; TCPsocket server,client; int bufSize = 1024; char message[bufSize]; int len; server = SDLNet_TCP_Open(&ip); client = SDLNet_TCP_Accept(server); len = SDLNet_TCP_Recv(client,message,bufSize); Here's a snippet. the buffer length "len" is set (i.e. message length) but I can't get to the data contents in the message buffer. Some sample bind_transmitter PDU data was sent by a random client to the server at that port. I can't read the PDU (SMPP).

    Read the article

  • Shell Script if else

    - by user34104
    #!/bin/bash echo "Int. a number" read num1 echo "Int. another numer" read num2 if ["$num1"="$num2"]; then echo "Equals" else echo "Dif" fi if["$num1"<0]; then echo "The number $num1 is negative" else if ["$num2"<0]; then echo "The number $num2 is negative" fi # this code is not working, i've something wrong when i see if the number is < 0. thanks

    Read the article

  • What PHP configuration and extensions are recommended for speed, efficiency and security?

    - by Sanoj
    I am setting up an Ubuntu server with nginx and PHP. I have read about many different configurations and extensions that could be added and it is pretty hard to know about all of them. I would like to hear from you, sysadmins, what PHP configuration and extensions do you recommend? I have read about: Suhosin for security Alternative PHP Cache for speed and efficiency Memcache for speed and efficiency PHP FastCGI Process Manager for speed and efficiency But I have no idea if they are good or not, and if I should use them together.

    Read the article

  • ungetc in Python

    - by Dragos Toader
    Some file read (readlines()) functions in Python copy the file contents to memory (as a list) I need to process a file that's too large to be copied in memory and as such need to use a file pointer (to access the file one byte at a time) -- as in C getc(). The additional requirement I have is that I'd like to rewind the file pointer to previous bytes like in C ungetc(). Is there a way to do this in Python? Also, in Python, I can read one line at a time with readline() Is there a way to read the previous line going backward?

    Read the article

  • 'Set = new HashSet' or 'HashSet = new Hashset'?

    - by Pureferret
    I'm intialising a HashSet like so in my program: Set<String> namesFilter = new HashSet<String>(); Is this functionally any different if I initilise like so? HashSet<String> namesFilter = new HashSet<String>(); I've read this about the collections interface, and I understand interfaces (well, except their use here). I've read this excerpt from Effective Java, and I've read this SO question, but I feel none the wiser. Is there a best practice in Java, and if so, why? My intuition is that it makes casting to a different type of Set easier in my first example. But then again, you'd only be casting to something that was a collection, and you could convert it by re-constructing it.

    Read the article

  • ASM programming, how to use loop?

    - by chris
    Hello. Im first time here.I am a college student. I've created a simple program by using assembly language. And im wondering if i can use loop method to run it almost samething as what it does below the program i posted. and im also eager to find someome who i can talk through MSN messanger so i can ask you questions right away.(if possible) ok thank you .MODEL small .STACK 400h .data prompt db 10,13,'Please enter a 3 digit number, example 100:',10,13,'$' ;10,13 cause to go to next line first_digit db 0d second_digit db 0d third_digit db 0d Not_prime db 10,13,'This number is not prime!',10,13,'$' prime db 10,13,'This number is prime!',10,13,'$' question db 10,13,'Do you want to contine Y/N $' counter dw 0d number dw 0d half dw ? .code Start: mov ax, @data ;establish access to the data segment mov ds, ax mov number, 0d LetsRoll: mov dx, offset prompt ; print the string (please enter a 3 digit...) mov ah, 9h int 21h ;execute ;read FIRST DIGIT mov ah, 1d ;bios code for read a keystroke int 21h ;call bios, it is understood that the ascii code will be returned in al mov first_digit, al ;may as well save a copy sub al, 30h ;Convert code to an actual integer cbw ;CONVERT BYTE TO WORD. This takes whatever number is in al and ;extends it to ax, doubling its size from 8 bits to 16 bits ;The first digit now occupies all of ax as an integer mov cx, 100d ;This is so we can calculate 100*1st digit +10*2nd digit + 3rd digit mul cx ;start to accumulate the 3 digit number in the variable imul cx ;it is understood that the other operand is ax ;AND that the result will use both dx::ax ;but we understand that dx will contain only leading zeros add number, ax ;save ;variable <number> now contains 1st digit * 10 ;---------------------------------------------------------------------- ;read SECOND DIGIT, multiply by 10 and add in mov ah, 1d ;bios code for read a keystroke int 21h ;call bios, it is understood that the ascii code will be returned in al mov second_digit, al ;may as well save a copy sub al, 30h ;Convert code to an actual integer cbw ;CONVERT BYTE TO WORD. This takes whatever number is in al and ;extends it to ax, boubling its size from 8 bits to 16 bits ;The first digit now occupies all of ax as an integer mov cx, 10d ;continue to accumulate the 3 digit number in the variable mul cx ;it is understood that the other operand is ax, containing first digit ;AND that the result will use both dx::ax ;but we understand that dx will contain only leading zeros. Ignore them add number, ax ;save -- nearly finished ;variable <number> now contains 1st digit * 100 + second digit * 10 ;---------------------------------------------------------------------- ;read THIRD DIGIT, add it in (no multiplication this time) mov ah, 1d ;bios code for read a keystroke int 21h ;call bios, it is understood that the ascii code will be returned in al mov third_digit, al ;may as well save a copy sub al, 30h ;Convert code to an actual integer cbw ;CONVERT BYTE TO WORD. This takes whatever number is in al and ;extends it to ax, boubling its size from 8 bits to 16 bits ;The first digit now occupies all of ax as an integer add number, ax ;Both my variable number and ax are 16 bits, so equal size mov ax, number ;copy contents of number to ax mov cx, 2h div cx ;Divide by cx mov half, ax ;copy the contents of ax to half mov cx, 2h; mov ax, number; ;copy numbers to ax xor dx, dx ;flush dx jmp prime_check ;jump to prime check print_question: mov dx, offset question ;print string (do you want to continue Y/N?) mov ah, 9h int 21h ;execute mov ah, 1h int 21h ;execute cmp al, 4eh ;compare je Exit ;jump to exit cmp al, 6eh ;compare je Exit ;jump to exit cmp al, 59h ;compare je Start ;jump to start cmp al, 79h ;compare je Start ;jump to start prime_check: div cx; ;Divide by cx cmp dx, 0h ;reset the value of dx je print_not_prime ;jump to not prime xor dx, dx; ;flush dx mov ax, number ;copy the contents of number to ax cmp cx, half ;compare half with cx je print_prime ;jump to print prime section inc cx; ;increment cx by one jmp prime_check ;repeat the prime check print_prime: mov dx, offset prime ;print string (this number is prime!) mov ah, 9h int 21h ;execute jmp print_question ;jumps to question (do you want to continue Y/N?) this is for repeat print_not_prime: mov dx, offset Not_prime ;print string (this number is not prime!) mov ah, 9h int 21h ;execute jmp print_question ;jumps to question (do you want to continue Y/N?) this is for repeat Exit: mov ah, 4ch int 21h ;execute exit END Start

    Read the article

  • What PHP configuration and extensions are recommended for efficiency and security?

    - by Sanoj
    I am setting up an Ubuntu VPS server with nginx and PHP. I have read about many different configurations and extensions that could be added and it is pretty hard to know about all of them. I would like to hear from you, sysadmins, what PHP configuration and extensions do you recommend? I have read about: Suhosin for security Alternative PHP Cache for efficiency PHP FastCGI Process Manager for efficiency But I have no idea if they are good or not, and if I should use them together.

    Read the article

  • Auto populate Outlook with other users' calendars

    - by bduncanj
    In Outlook 2007, when in Calendar view, there's a category (group) of calendars on the left hand bar titled "People's Calendars". We're migrating from a system where all employees have access to read and write to all other employees' calendars (via a 3rd party Web Calendar). Is it possible, from an admin level, to auto-populate this People's Calendars category in everyone's Outlook with all the employees in the company, and grant everyone read / write access to everyone else's calendars? (Running Exchange 2010) Thanks, Duncan

    Read the article

  • What happens after a packet is captured?

    - by Rayne
    Hi all, I've been reading about what happens after packets are captured by NICs, and the more I read, the more I'm confused. Firstly, I've read that traditionally, after a packet is captured by the NIC, it gets copied to a block of memory in the kernel space, then to the user space for whatever application that then works on the packet data. Then I read about DMA, where the NIC directly copies the packet into memory, bypassing the CPU. So is the NIC - kernel memory - User space memory flow still valid? Also, do most NIC (e.g. Myricom) use DMA to improve packet capture rates? Secondly, does RSS (Receive Side Scaling) work similarly in both Windows and Linux systems? I can only find detailed explanations on how RSS works in MSDN articles, where they talk about how RSS (and MSI-X) works on Windows Server 2008. But the same concept of RSS and MSI-X should still apply for linux systems, right? Thank you. Regards, Rayne

    Read the article

  • What is the best option for reading Java property files?

    - by Mr Morgan
    Hello I have an application which uses a servlet to read an intialization parameter from web.xml for the location of a property file. The serlvet then creates an instance of a class which stores the location of the file for other programs to read as required. This class has appropriate get and set methods. But my question concerns access to the properties: should the physical property file be read by each program as at runtime or should the properties be stored in memory instead? The properties are not currently altered at runtime but this could change? I've seen various alternative approaches but am not sure which is best. Thanks Mr Morgan

    Read the article

  • How to create a custom yaml config file in Symfony

    - by Guillaume Flandre
    What I want to do is quite simple: store data in a custom config file that I want to read later on. I created my file something.yml that I put in the global config directory. It looks like that: prod: test: ok dev: test: ko all: foo: bar john: doe Then I copied the config_handlers.yml and also put it in the config directory and added the following at the top of the file: config/something.yml: class: sfDefineEnvironmentConfigHandler param: prefix: something_ But if I'm calling sfConfig::get("something_foo"); I keep getting NULL. What did I do wrong? I just want to read values, so no need to create a custome config handler, right? I've read the doc here: http://www.symfony-project.org/book/1_2/19-Mastering-Symfony-s-Configuration-Files even though I'm running 1.4 (I don't think that changed since then). Edit: Of course I can use sfYaml::load() but I'd like to do things in a better way.

    Read the article

  • Cannot share files on USB drive between Windows 98 and Windows 2000

    - by Ken Pespisa
    I've run into a strange situation where I can't share files between Windows 98 and Windows 2000 using a USB flash drive. Files I put on the Win98 machine can be read by that machine, but not by the Win2k machine. And likewise, I can add and read files on that drive from the Win2k machine, but those files don't appear on the drive when accessed from the Win98 machine. Anyone have ideas as to what could be the cause of this?

    Read the article

  • installing ruby 1.9.3 of osx mavricsmavrics

    - by user1648962
    I am trying to install ruby 1.9.3 on my osx 10.9 operating system and I keep getting the following error : Error running 'requirements_osx_port_update_system ruby-1.9.3-p448', please read /Users/ramesh/.rvm/log/1383430694_ruby-1.9.3-p448/update_system.log Requirements installation failed with status: 1. I am using the following command to do the installtion : rvm install 1.9.3 The complete log is as given below : Ramesh:Downloads ramesh$ rvm install 1.9.3 Searching for binary rubies, this might take some time. No binary rubies available for: osx/10.9/x86_64/ruby-1.9.3-p448. Continuing with compilation. Please read 'rvm help mount' to get more information on binary rubies. Checking requirements for osx. Installing requirements for osx. Updating system............................................................................................................................................................................................................................................................. Error running 'requirements_osx_port_update_system ruby-1.9.3-p448', please read /Users/ramesh/.rvm/log/1383430694_ruby-1.9.3-p448/update_system.log Requirements installation failed with status: 1. Ramesh:Downloads ramesh$ clear

    Read the article

  • How to turn off the cursor in OpenOffice

    - by hcs42
    When OpenOffice opens a file in read-only mode, it does not show a cursor, and the arrow keys (up and down) will move the page instead of the cursor. (By "cursor", I mean the blinking thing also called "caret" and not the mouse cursor.) Is there any way to turn off the cursor when the document is not read-only?

    Read the article

  • Is there any USB2.0 data transfer chunk size limit?

    - by goldenmean
    With one read() or write() at a time, can we increase the bulk data size over USB interface? For example, I want to transfer chunk of 1024 (1K) bytes data and if the device has limitations of only 64bytes, is there any way I can increase the packet size for read() and write() system call over USB? Is there any limitation on size of data transfer over USB in a host-device environment?

    Read the article

  • F# working with DataReader

    - by mamu
    let getBytesData x = let len = reader.GetBytes(1, int64 0, null, 0, 0); // Create a buffer to hold the bytes, and then // read the bytes from the DataTableReader. let buffer : byte array = [||] reader.GetBytes(1, int64 0, buffer, 0, int32 len) |> ignore buffer let retVal = List [ while reader.Read() do yield (reader.GetString(0), getBytesData reader, reader.GetDateTime(2)) ] I have above code to read bytes[] from datareader. getBytesData function takes reader and returns bytes[] from reader. everything works fine but it getBytesData function is working very non-functional way. Is there any way i can optimize in F#? Sorry for kind of question, but i have started a new project on F# to squeeze all juice out of it, so trying to get each line most optimal way

    Read the article

  • RMagick returns nil reading JPEG

    - by ysproduction
    When I try to open a JPEG format file in Rails using RMagick, it always return nil with any jpg file. Other file formats open well. $ script/console Loading development environment (Rails 2.3.4) >> require 'RMagick' >> img = Image.read("1.gif").first => 1.gif GIF 230x100 230x100+0+0 PseudoClass 256c 8-bit 2kb >> img = Image.read("1.png").first => 1.png PNG 1280x800 1280x800+0+0 DirectClass 8-bit 156kb >> img = Image.read("1.jpg").first => nil Why this happens?

    Read the article

  • Reading ASCII numbers using "D" instead of "E" for scientific notation using C

    - by Arrieta
    Hello, I have a list of numbers which looks like this: 1.234D+1 or 1.234D-02. I want to read the file using C. The function atof will merely ignore the D and translate only the mantissa. The function fscanf will not accept the format '%10.6e' because it expects an E instead of a D in the exponent. When I ran into this problem in Python, I have up and merely used a string substitution before converting from string to float. But in C, I am sure there must be another way. So, how would you read a file with numbers using D instead of E for scientific notation? Notice that I do not mean how to read the strings themselves, but rather how to convert them to floats. Thanks.

    Read the article

  • Broken pipe error in rails with memcached

    - by abronte
    I keep running into this error MemCacheError (Broken pipe): Broken pipe on my Rails app and I can't figure out why. When I access memcached via Rails.cache in my controller, the first 1 or 2 read/writes always seems to throw the broken pipe error. But when I access memcached by creating a new object, ActiveSupport::Cache::MemCacheStore.new, I don't seem to get this error. I also access memcached in another ruby process, and the first read always has this error regardless of the way I access memcached. I did implement a work around just by retrying the read but id rather have a better long term solution. Currently the only time I see this problem is after I restart memcached. I'm using Rails 2.3.5 and memcached 1.4.4 (I've also tried this with memcached 1.2.2).

    Read the article

  • File/folder permissions and groups on Linux with Apache

    - by phobia
    I'm trying to learn about permissions on linux webserver with apache. Some clues to the system: The server I have to play around with is Fedora based. Apache runs as apache:apache. To allow for e.g. php to write to a file the file needs to be chmod 777. 755 is not sufficiant. What I'm wondering is basically how set up permissions like they should be on e.g. a "shared web host". My main problem is that if I set a permission so that one user cannot access anothers home folder, then apache can't read from the public_html folder either. To keep the users out I need to set chmod 700. But to let apache to read I need to have at least execute on world, so a 701 basically works, but won't let some users in. So I'm really stuck on what to do. Have been concidering adding the apache user to the frous grours below to avoid having to add the world execute flag, but is that a bad thing? Should it be the other way around, the users in the groups below should also be in the apache group? I was aiming at having 4 groups: 1. webapp same as dev_int, but is the only one that can go inside the webapp/live folder to e.g. do an update from the repo. 2. dev_int can read,write and execute everything in the "web root", including the two below, but nothing outside of the web root 3. dev_ext can read write and execute in all client folders, but cannot access anything outside of the webapp root 4. clientsBasic ftp accounts. Has a home folder with a public_html, but cannot access any other home folders An example of folder structure: webroot    no users in the aforementioned groups can go outside of here some_project    :dev_int only webapp live    :webapp only staging    :dev_int and :dev_ext clients    :dev_int and :dev_ext client_1    :dev_int, :dev_ext and client1:clients public_html dev developer_1    developer_1:dev_int OR :dev_ext public_html

    Read the article

  • problem using base64 encoder and InputStreamReader

    - by karoberts
    I have some CLOB columns in a database that I need to put Base64 encoded binary files in. These files can be large, so I need to stream them, I can't read the whole thing in at once. I'm using org.apache.commons.codec.binary.Base64InputStream to do the encoding, and I'm running into a problem. My code is essentially this FileInputStream fis = new FileInputStream(file); Base64InputStream b64is = new Base64InputStream(fis, true, -1, null); InputStreamReader reader = new InputStreamReader(b64is); preparedStatement.setCharacterStream(1, reader); When I run the above code, I get one of these during the execution of the update java.io.IOException: Underlying input stream returned zero bytes, it is thrown deep in the InputStreamReader code. Why would this not work? It seems to me like the reader would attempt to read from the base 64 stream, which would read from the file stream, and everything should be happy.

    Read the article

< Previous Page | 139 140 141 142 143 144 145 146 147 148 149 150  | Next Page >