Search Results

Search found 6706 results on 269 pages for 'power supply'.

Page 157/269 | < Previous Page | 153 154 155 156 157 158 159 160 161 162 163 164  | Next Page >

  • Windows detected a hard disk failure* - what should I do?

    - by bart
    I'm using Windows 7 x64 Ultimate, I'm getting windows error popups like this one for about 3 days, multiple times a day: This Samsung SpinPoint F3 HD502HJ 500 GB is about 2 years old and I already checked it with Samsung ES Tool 3.0, did all the scans (took hours) and everything is fine! I have no malware, viruses and this started to happen after I have had some electrcity issues at my house (multiple power surges / overvolatege during the night, PC was connected, but turned off), any ideas? What other test should I perform? I believe the disk could be damaged, but then diagnostic tools should prove this, right? *in fact "Windows detected hard disk problem" but I was unable to put word "problem" within the title as well.

    Read the article

  • Forgot to unmount/eject external hdd, lost moved files. OSX

    - by balupton
    So I was using my mac with my external hard drive connected via USB. I moved about 10gigs of data to it (via drag and drop while holding command to move the files rather than to copy them). They moved to the drive alright, but as I was having some issues and finder crashed after the transfer, I was unable to eject the volume and later everything froze so I had to do a hard restart (hold the power button). When I remounted the volume (plugged the external hdd back in) it no longer had any of the files which I moved onto it. How can I recover these files, as it was a lot of data! Cheers.

    Read the article

  • How to recover basic networking utilities on Debian?

    - by Rizo
    I am administrating a small server for LAN, providing basic services such as web-proxy, ldap, kerberos, afs, etc. Yesterday there was a power cut so server halted. When I restarted it no network interfaces were available and configured. I tried restarting networking daemon but it just exited with 0 status. So I tried to run one of the interfaces manually, but ifup and ifdown commands simply are not there. No only in PATH, but they disappeared from /sbin. So my question is: how can I recover these network utilities?

    Read the article

  • Mac Book Pro wakes up in my backpack

    - by J. Pablo Fernández
    This has happened to me twice: I press the power button on my Mac Book Pro, choose sleep, close it, unplug everything, confirm that is off (by pressing my ear to it) and put it in my bag. Some minutes later, the laptop wakes up by itself. Both times I caught it in time. The second time it was so hot I couldn't touch some parts -- it refused to actually wake up, and the screen was blank. Restarting it worked though. Any ideas what might be going on and/or how to prevent this? More details: It's a Mac Book Pro unibody 15" from 2009.

    Read the article

  • Should I install Windows 7 on a 3 years old PC?

    - by Jitendra vyas
    This is my PC configuration, Should I upgrade my Windows XP to Windows 7. Currently I'm using Windows XP SP3 32 bit. Now will I get same performance or better performance or bad performance if I install Windows 7 on this system? Or would sticking with XP be better? Memory (RAM): 1472 MB DDR RAM (not DDR 2) CPU Info: AMD Sempron(tm) Processor 2500+ CPU Speed: 1398.7 MHz Sound card: Vinyl AC'97 Audio (WAVE) Display Adapters: VIA/S3G UniChrome Pro IGP | NetMeeting driver | RDPDD Chained DD Network Adapters: Bluetooth Device (Personal Area Network) | WAN (PPP/SLIP) Interface Hard Disks: 300 GB SATA HDD Manufacturer: Phoenix Technologies, LTD Product Make: MS-7142 AC Power Status: OnLine BIOS Info: AT/AT COMPATIBLE | 01/18/06 | VIAK8M - 42302e31 Motherboard: MICRO-STAR INTERNATIONAL CO., LTD MS-7142 Modem: ZTE USB Modem FFFE CDMA :

    Read the article

  • Internet (Flash) video without a PC

    - by Rob Allen
    I am looking to retire my HTPC. So much of what we do with it can be done with one of our video game consoles or an AppleTV that is seems like a waste of space, power and time to maintain. The trouble is that my wife does streaming yoga classes served up via specific websites. I am assuming they are Flash based and so far I have been unable to find Apps for these content providers. My question is, is there a GOOD way to handle flash-based or even HTML5/h.264 web content with one of the other Internet enabled devices in our stack? So far we have: Nintendo Wii Playstation 3 XBox 360 And we're looking to purchase a current generation AppleTV. update The sites are YogisAnonymmous.com and YogaJournal.com, both are confirmed as Flash.

    Read the article

  • Windows Server 2008 R2 Server Core with AD Role having GUI Admin Console

    - by Robert Koritnik
    I would like to setup a machine with Windows Server 2008 R2 Server Core and install following server roles: Active Directory Domain Services Active Directory Federation Services Active Directory Lightweight Directory Services (I'm not sure whether I actually need this one - see note below) I'm obviously going to install Enterprise Edition. Question Can I have an AD administration graphical user interface to manage Active Directory on Server Core machine? I would really like to have it, because I'm not so keen to do stuff using power-shell, because I've never managed AD as well, so a GUI would be much more helpful, because I could at least visualize it a bit better and maybe understand AD structures. Note: I'm setting up development environment machine as well and installing Sharepoint Foundation 2010 on in so it would use this AD machine.

    Read the article

  • Dedicated GPU in Dell PowerEdge C1100

    - by Eli Gundry
    We recently purchased a Dell PowerEdge C1100 off lease with the initention of using it for graphics processing. We installed an AMD HD 7000 series GPU in it that runs off of board power and it sends video to the display. That said, the video is very choppy, leading us to belive that the onboard video is doing all the processing and sending it to the card. Is there any way to either disable the VGA on this server or tell the OS to only use the dedicated card. More info: The server is running REHL 6.4 The graphics running the proprietary AMD drivers The video card only works in OS and does not show the BIOS on boot (we know that it's impossible to change this) Any ideas, guys? Update We are now thinking that the GPU is doing the graphics processing, but not working at the full speed of the PCI bus. Which is odd, because it is an x16 slot, but probably optimized to use a RAID card (if that makes any sense). Is there any way to remedy the choppy graphics on this server?

    Read the article

  • How to change the color of Razer Mamba?

    - by Delphy
    I just bought a Razer Mamba and I was in the process of configuring it when I noticed that the "Lighting and Power" tab was just "Lighting" and didn't give me the option to change thing. I've seen Youtube videos and I'm wondering how to get the same Razer Configuration program as all these other people. I went to the Razer site and downloaded the most recent drivers but no help there. Something is missing and I don't know what. I am trying to get it run on Windows 7.

    Read the article

  • Computer restarts without warning; code bcc116

    - by Robert C.
    Processor: Intel i5 4430 4-Core 4x3Ghz Motherboard: msi h87-g41 Graphics Card: Nvidia GTX760 Power supply: eps-750 cm RAM: 8GB I bought a new assembled gaming PC which worked fine for a few days. Then it started rebooting without warning. After it restarts windows 7 gives me an bbc 116 error code. Apparently it's something to do with my video card, either it overheating or wrong drivers. I've installed the latest driver from Nvidia for my graphics card. Since it's brand new it can't be dust, I'm running it with its lid open to see if the problem persists. I'm also running prime95 now to see if it tells me anything else. Using core temp it tells me that my CPU reaches up to 95° celsius with the blend stress test from prime95. Aaaand it just peaked to 100°. Of course it doesn't reach these temperatures at all while idle/gaming. I'm gonna let prime95 run for a night and to see what happens. Until then does anyone know what I should do next?

    Read the article

  • Major Issue with Asus M4A78T-E Bios

    - by user114721
    I am having major issues with my bios and I have tried three different forums in hopes that there is someone out there that can help me.... The issue is that every single time I turn off my computer, when I turn it back on the bios resets and tries to boot from a floppy drive....first problem is I dont have a floppy drive and secondly it does not read my HDD.... I tried everything to fix this...I tried replacing the cmos battery, I tried replacing the sata cable, and I tried a different sata port....none of these things seem to be working. Now the messed up part about all of this is that i am on my computer right now....If I take the battery out and put it back in and setup the bios again manually I am able to get into my computer...but this is NOT normal... Why is my bios resetting constantly when I power down my computer? Please assist me I need my computer for business

    Read the article

  • How should I remotely manage Dell Poweredge 2850 running Ubuntu server?

    - by Saul
    First I've got to say I'm a Linux / Ubuntu novice, so go gentle on me as I'm on day 3. I've managed to get Ubuntu server Ubuntu 8.04 LTS installed and running on the Poweredge 1850 I bought off ebay. The box will go in a rack at my office but I want to be able to work on it and power on and off from home and I gather that (maybe) IPMI over LAN might be the way to do this, or maybe its something to do with BMC or something? I want to be able to administer/manage from a client PC at home running XP. I will be configuring the office router to port forward port 80 and 443 to the Ubuntu server running Apache2, and I'm puzzled about how the remote management works (unless it comes on a different port forwarded to a different internal IP) Thanks for any help

    Read the article

  • Internal and External DNS from Different Servers, Same Zone

    - by Shane
    Hello All, I am either having trouble understanding how DNS works, or I am having trouble configuring my DNS correctly (either one isn't good). I am currently working with a domain, I'll call it webdomain.com, and I need to allow all of our internal users to get out to dotster to get our public DNS entries just like the rest of the world. Then, on top of that, I want to be able to supply just a few override DNS entries for testing servers and equipment that is not available publically. As an example: public.webdomain.com - should get this from dotster outside.webdomain.com - should get this from dotster as well testing.webdomain.com - should get this from my internal dns controller The problem that I seem to be running into at every turn is that if I have an internal DNS controller that contains a zone for webdomain.com then I can get my specified internal entries but never get anything from the public DNS server. This holds true regardless of the type of DNS server I use also--I have tried both a Linux Bind9 and a Windows 2008 Domain Controller. I guess my big question is: am I being unreasonable to think that a system should be able to check my specified internal DNS and in the case where a requested entry doesn't exist it should fail over to the specified public dns server -OR- is this just not the way DNS works and I am lost in the sauce? It seems like it should be as simple as telling my internal DNS server to forward any requests that it can't fulfill to dotster, but that doesn't seem to work. Could this be a firewall issue? Thanks in advance

    Read the article

  • Node.js server crashes , Database operations halfway?

    - by Ranadeep
    I have a node.js app with mongodb backend going to production in a week and i have few doubts on how to handle app crashes and restart . Say i have a simple route /followUser in which i have 2 database operations /followUser ----->Update User1 Document.followers = User2 ----->Update User2 Document.followers = User1 ----->Some other mongodb(via mongoose)operation What happens if there is a server crash(due to power failure or maybe the remote mongodb server is down ) like this scenario : ----->Update User1 Document.followers = User2 SERVER CRASHED , FOREVER RESTARTS NODE What happens to these operations below ? The system is now in inconsistent state and i may have error everytime i ask for User2 followers ----->Update User2 Document.followers = User1 ----->Some other mongodb(via mongoose)operation Also please recommend good logging and restart/monitor modules for apps running in linux

    Read the article

  • Compaq 610 fan is constantly on and noisy, base is fairly hot too

    - by Dave
    The fans on both of my HP Compaq 610s are constantly on and the base is fairly hot and I don't know if this is standard issue. HP assures me that this is unusual and that I should return them as DOA. Because both laptops have this problem, I'm thinking that this might be a design flaw rather than a one-off problem. I've updated the BIOS and using their recommended power settings. Am I missing something? Is there anything I can do to fix it?

    Read the article

  • How do you change your Airport or Ethernet MAC address in Mac OS X 10.6?

    - by Dave Gallagher
    I have a MacBook Pro and would like to set a custom MAC address for either my Airport WiFi card, or Ethernet port. In older versions of Mac OS X, you could do it like this: $ sudo ifconfig en0 ether 00:11:22:33:44:55 // Ethernet $ sudo ifconfig en1 lladdr AA:BB:CC:DD:EE:FF // Airport For it to work on Airport, you'd have to power it on (e.g. $ sudo ifconfig en1 up), ensure it's not connected to any wireless network, and execute the command. I'm aware such a change won't propagate across reboots. Unfortunately, this doesn't work on Mac OS X 10.6.6 anymore. Apple appears to have removed the functionality (the command fails silently). Does anyone have any idea how to do it? Thanks for any help you can offer! :)

    Read the article

  • Thinkpad CPU temperature reaches 100°C after 10 minutes of heavy use

    - by Nicolas Raoul
    Less than two years ago, I bought a Lenovo Thinkpad R500. When using the CPU heavily, it sometimes decides to reboot. I am using Linux, and a widget shows me the CPU temperature. The PC usually reboots when the temperature of the first core gets over 100°C Since I switched from Ubuntu 2010.10 32bit to Ubuntu 2011.04 64bit, it crashes much more often. I survive using these techniques: When in the office, I use a laptopcooler. When outside, I underclock to 800 MHz, by doing so it does not get too warm. QUESTION: Is it normal that a Thinkpad crashes if the CPU is at 100% for more than 10 minutes? How can I use the full power of my computer, for instance when showing CPU-hungry business intelligence tools to clients? The computer does not really feel that hot. Maybe the sensor itself is reporting wrong temperatures? Can I tell the BIOS to ignore it?

    Read the article

  • Skipping scheduled self-tests and predicting drive EOL

    - by Steve Madsen
    For a few weeks now, smartd has been reporting that it is skipping some of its scheduled self-tests on the weekends: Apr 24 18:29:32 calvin smartd[4758]: Device: /dev/sda, skip scheduled Offline Immediate Test; 40% remaining of current Self-Test. Apr 24 18:29:33 calvin smartd[4758]: Device: /dev/sdb, skip scheduled Offline Immediate Test; 50% remaining of current Self-Test. The drives in this RAID-1 array are set to run an offline test four times a day, a short self-test at 2am every day, and a long self-test on Saturdays at 2am. For some reason, it looks like the long self-test is taking longer, causing the other scheduled tests to be skipped. First question: is this a sign of likely drive failure? Then today, smartd reported that a self-test failed. Here is the output of smartctl -a /dev/sdb: smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3250823AS Serial Number: 3ND1GNBC Firmware Version: 3.03 User Capacity: 250,059,350,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Apr 25 13:15:34 2010 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 047 039 006 Pre-fail Always - 168450357 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 33 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 9 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 654745480 9 Power_On_Hours 0x0032 055 055 000 Old_age Always - 40141 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 51 194 Temperature_Celsius 0x0022 037 062 000 Old_age Always - 37 (0 17 0 0) 195 Hardware_ECC_Recovered 0x001a 047 039 000 Old_age Always - 168450357 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 40131 - # 2 Extended offline Completed: read failure 30% 40129 379795511 # 3 Short offline Completed without error 00% 40084 - # 4 Short offline Completed without error 00% 40060 - # 5 Short offline Completed without error 00% 40036 - # 6 Short offline Completed without error 00% 40013 - # 7 Short offline Completed without error 00% 39990 - # 8 Extended offline Completed without error 00% 39977 - # 9 Short offline Completed without error 00% 39919 - #10 Short offline Completed without error 00% 39895 - #11 Short offline Completed without error 00% 39872 - #12 Short offline Completed without error 00% 39848 - #13 Short offline Completed without error 00% 39824 - #14 Short offline Completed without error 00% 39801 - #15 Extended offline Completed without error 00% 39789 - #16 Short offline Completed without error 00% 39754 - #17 Short offline Completed without error 00% 39732 - #18 Short offline Completed without error 00% 39707 - #19 Short offline Completed without error 00% 39683 - #20 Short offline Completed without error 00% 39660 - #21 Short offline Completed without error 00% 39636 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. Given that this drive is about 4.5 years old, I am probably tempting fate by keeping it in service. SMART doesn't seem to get much respect as a reliable way to predict drive failure. What else can I use to get an early indication of drive failure?

    Read the article

  • How do I know what hardware to buy to meet my needs?

    - by Darth Android
    While Stack Exchange does not permit shopping recommendations, it doesn't provide any general advice to consider when buying hardware. So, instead of just telling those that ask what to buy that it's not allowed, let's tell them how to figure out what they need. When looking forward to build a computer, how do I know what to buy? How do I find out if a given CPU will be enough for a certain game or application that I want to run? How do I find out if a given graphics card will be enough for a certain game or application? What is important when looking at motherboards? How much memory do I need? How do I know how much wattage I need for a power supply? What size case do I need? What relevant standards do I need to read up on and be aware of? PCI, PCIe, SATA, USB 2.0, USB 3.0, etc... What "gotchas" do I need to be on the lookout for? Please keep responses generation-agnostic to ensure they will be helpful to our future users. :)

    Read the article

  • Cannot see http (apache) server outside home network

    - by user165155
    Ive been racking my brain with this all evening. Power went out with a tstorm today, started back up my server... running apache and a team speak server on it. TS is great, cant see my web page outside my network! Firewall is disabled on the pc running it (centos btw), apache is running and working. correct ports are forwarded on my router (my isp blocks port 80). Ive tried changing ports, pretty much everything i can think of. httpd.conf is pointing to the correct addy and port, and my domain is pointing to the correct external ip. Im at a loss, any ideas out there?

    Read the article

  • USB 3.0 not functioning fully

    - by Simon Sheehan
    After installing GNU/Linux today onto my Lenovo Y570 laptop, I ran into an issue quickly - the USB 3.0 support. 2/3 of my USB ports are 3.0 so I kind of need them. The ports are powered at the very least - my phone is charging from one, however, plugging in external drives, USB drives, or even a mouse gives no response. The drives spin up, etc, but they do nothing more than that. So there is power, but no information flowing to them. What am I missing here? What can I try to enable to make things work?

    Read the article

  • Cheapest server per gigabit throughput [closed]

    - by nethgirb
    I'm looking for a set of servers for performance testing a network, and secondarily testing some applications on the servers. Their most important task is simply to pump out data: from an application like memcached or just dumped from a large file in memory into a TCP flow (i.e., disk performance doesn't matter). This should happen over one or more 1 gigabit Ethernet ports, and the machines should run Linux (ideally), or perhaps Mac OS X or some other *nix. Other than that, there are few constraints (e.g., even something ARM-based could be fine). So here's the question: What's the cheapest server per gigabit? Price and power are both considerations.

    Read the article

  • HP ProLiant Smart Array "lock up" code 0x11

    - by ewwhite
    I've a ProLiant DL580 G7 server that experienced a storage subsystem failure during production. The system appeared available and responded to pings, but all I/O access stalled (the system load must have been 100+). The ASR did not trigger at the specified watchdog timeout. I had to force a reboot from the ILO. During POST, I received the following error: A controller failure event occurred prior to this power-up. (Previous lock up code = 0x11) I haven't pulled the ADU report yet, but I'm curious as to what this error actually means. I was not responsible for the the installation, but can see that the firmware is very old. But if there's anything else I should know about the error, I'd like to know for the post-mortem report. edit - I should add that the server had 95 days of uptime prior to the lock up.

    Read the article

  • TrueCrypt Failing to Decrypt External Hard Drive after changing Enclosures

    - by Anx Ara
    I have a 4TB external hard drive that was previously encrypted using TrueCrypt. The power source on the hard drive enclosure failed, so I had to switch the hard drive itself into a new enclosure. I can no longer decrypt the hard drive using TrueCrypt, as it says my password is wrong. I am certain that I entering the correct password. Additionally, in TrueCrypt, when I try to mount the volume under "Select Device", it shows the following: Harddisk 5: 3.6TB Device\Harddisk5\Partition 1 H: 465GB Whereas before I changed the enclosure it would show: Harddisk 5: 3.6TB Device\Harddisk5\Partition 1 H: 3.6TB I am on a Windows 8 PC and using TrueCrypt 7.1a. How can I get it to decrypt properly?

    Read the article

  • Zero-channel RAID for High Performance MySQL Server (IBM ServeRAID 8k) : Any Experience/Recommendati

    - by prs563
    We are getting this IBM rack mount server and it has this IBM ServeRAID8k storage controller with Zero-Channel RAID and 256MB battery backed cache. It can support RAID 10 which we need for our high performance MySQL server which will have 4 x 15000K RPM 300GB SAS HDD. This is mission-critical and we want as much bandwidth and performance. Is this a good card or should we replace with another IBM RAID card? IBM ServeRAID 8k SAS Controller option provides 256 MB of battery backed 533 MHz DDR2 standard power memory in a fixed mounting arrangement. The device attaches directly to IBM planar which can provide full RAID capability. Manufacturer IBM Manufacturer Part # 25R8064 Cost Central Item # 10025907 Product Description IBM ServeRAID 8k SAS - Storage controller (zero-channel RAID) - RAID 0, 1, 5, 6, 10, 1E Device Type Storage controller (zero-channel RAID) - plug-in module Buffer Size 256 MB Supported Devices Disk array (RAID) Max Storage Devices Qty 8 RAID Level RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 1E Manufacturer Warranty 1 year warranty

    Read the article

< Previous Page | 153 154 155 156 157 158 159 160 161 162 163 164  | Next Page >