Search Results

Search found 16755 results on 671 pages for 'gnome power manager'.

Page 170/671 | < Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >

  • Jboss logging issue

    - by balaji
    I'm Working as deployer and server administrator. We use Jboss 4.0x AS to deploy our applications. The issue I'm facing is, Whenever we redeploy/restart the server, server.log is getting created but after sometime the logging goes off. Yes it is not at all updating the server.log file. Due to this, we could not trace the other critical issues we have. Actually we have two separate nodes and we do deploy/restarting the server separately on two nodes. We are facing the issue in both of our test and production environment. I could not trace out where exactly the issue is. Could you please help me in resolving the issue? If we have any other issues, we can check the log files. If log itself is not getting updated/logged, how can we move further in analyzing the issues without the recent/updated logs? Below are the logs found in the stdout.log: 18:55:50,303 INFO [Server] Core system initialized 18:55:52,296 INFO [WebService] Using RMI server codebase: http://kl121tez.is.klmcorp.net:8083/ 18:55:52,313 INFO [Log4jService$URLWatchTimerTask] Configuring from URL: resource:log4j.xml 18:55:52,860 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasRBPFTraceLogger without a class name. 18:55:52,860 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasRBPFMessageLogger without a class name. 18:55:54,273 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasCacheTraceLogger without a class name. 18:55:54,274 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasCacheMessageLogger without a class name. 18:55:54,334 ERROR [STDERR] LOG0026E The Log Manager cannot create the object JACCTraceLogger without a class name. 18:55:54,334 ERROR [STDERR] LOG0026E The Log Manager cannot create the object JACCMessageLogger without a class name. 18:55:56,059 INFO [ServiceEndpointManager] WebServices: jbossws-1.0.3.SP1 (date=200609291417) 18:55:56,635 INFO [Embedded] Catalina naming disabled 18:55:56,671 INFO [ClusterRuleSetFactory] Unable to find a cluster rule set in the classpath. Will load the default rule set. 18:55:56,672 INFO [ClusterRuleSetFactory] Unable to find a cluster rule set in the classpath. Will load the default rule set. 18:55:56,843 INFO [Http11BaseProtocol] Initializing Coyote HTTP/1.1 on http-0.0.0.0-8180 18:55:56,844 INFO [Catalina] Initialization processed in 172 ms 18:55:56,844 INFO [StandardService] Starting service jboss.web

    Read the article

  • Cables for building a computer

    - by Faken
    I'm looking at building a computer and I have already done a whole bunch of research the topic and I think I know what I'm doing. My question is where do all the cables required for connecting everything come from? I'm pretty sure that the cables required come from their respective components (power connectors from the power supply, assorted cables from the motherboard, ect). However nowhere have I seen it explicitly stated that the cables come with the component I am buying. Just to confirm, if I buy all the components needed for a basic computer (CPU, motherboard, power supply, case, ram, video card, hard drive) from a website, say newegg, will I have all the screws, cables,connectors, and components to put together a working computer or will I need to buy some cables somewhere?

    Read the article

  • While updating the firmware on my parent's WNR3500v1, I bricked it

    - by Matt
    While updating the firmware on my parent's WNR3500v1, I bricked it. Basically, all that happens now is the power light just flashed. I tried pressing the factory reset button for up to a minute with the power on as well as with the power off. To no avail. Is there anything that can be done other than try to RMA it? Googling around, I found nothing promising. I'm wondering if anyone else has any other solution.

    Read the article

  • Notebook computer battery says: plugged in but not charging with no further information. Is the bat

    - by Jian Lin
    My 1.5 year old Dell Studio 15 notebook computer has a battery and I keep it attached to the notebook but 98% of the time I just plug in the power adapter. Lately when I unplugged the power adapter, the battery was only good for 10 minutes, and a few days ago, when I unplugged the power adapter, the computer simply turned off. When clicking on the battery icon on Win 7, it says "Plugged in, not charging": is the battery dead? Or can Win 7 have any option to not charge the battery? It is a Dell Studio 15, I wonder if in such case, it looks like it can be a manufacture's defect, would Dell replace the battery? (if there was a recall, then they probably would, i think). The notebook is 1.5 year old.

    Read the article

  • Can operator<< in derived class call another operator<< in base class in c++?

    - by ivory
    In my code, Manager is derived from Employee and each of them have an operator<< override. class Employee{ protected: int salary; int rank; public: int getSalary()const{return salary;} int getRank()const{return rank;} Employee(int s, int r):salary(s), rank(r){}; }; ostream& operator<< (ostream& out, Employee& e){ out << "Salary: " << e.getSalary() << " Rank: " << e.getRank() << endl; return out; } class Manager: public Employee{ public: Manager(int s, int r): Employee(s, r){}; }; ostream& operator<< (ostream& out, Manager& m){ out << "Manager: "; cout << (Employee)m << endl; //can not compile, how to call function of Employee? return out; } I hoped cout << (Employee)m << endl; would call ostream& operator<< (ostream& out, Employee& e), but it failed.

    Read the article

  • Aggregate Functions on subsets of data based on current row values with SQL

    - by aasukisuki
    Hopefully that title makes sense... Let's say I have an employee table: ID | Name | Title | Salary ---------------------------- 1 | Bob | Manager | 15285 2 | Joe | Worker | 10250 3 | Al | Worker | 11050 4 | Paul | Manager | 16025 5 | John | Worker | 10450 What I'd like to do is write a query that will give me the above table, along with an averaged salary column, based on the employee title: ID | Name | Title | Salary | Pos Avg -------------------------------------- 1 | Bob | Manager | 15285 | 15655 2 | Joe | Worker | 10250 | 10583 3 | Al | Worker | 11050 | 10583 4 | Paul | Manager | 16025 | 15655 5 | John | Worker | 10450 | 10583 I've tried doing this with a sub-query along the lines of: Select *, (select Avg(e2.salary) from employee e2 where e2.title = e.title) from employee e But I've come to realize that the sub-query is executed first, and has no knowledge of the table alias'd e I'm sure I'm missing something REALLY obvious here, can anyone point me in the right diretion?

    Read the article

  • Ubuntu 9.10 is not starting on netbook

    - by anonymous
    I installed Ubuntu 9.10 onto my external hard drive cause it's cool to be able to borrow a friend's laptop and be able to have my entire system. It works on the 2 systems i tested it on: my desktop and my mom's laptop. I had to work on something earlier so i borrowed my friend's netbook. I started it up, chose Ubuntu 9.10.20 and it got to the Ubuntu loading screen with the 3 people holding hands right before user selection then it suddenly went black. Naturally, i freaked out because it wasn't my laptop. I held the power button down and reset the netbook but the screen was still black, it didn't even show the BIOS. I repeated the process without my hard drive, and it was still black without the BIOS showing up. I had to remove the battery, plug it to a power source, and power up to start the netbook up again. Can anyone tell me what happened?

    Read the article

  • MySQL multidimensional arrays...

    - by jay
    What is the best way to store data that is dynamic in nature using MySQL? Let's say I have a table in which one item is "dynamic". For some entries I need to store one value, but for others it could be one hundred values. For example let's say I have the following simple table: CREATE TABLE manager ( name char(50), worker_1_name(50), worker_2_name(50), ... worker_N_name(50) ); Clearly, this is not an ideal way to set up a database. Because I have to accommodate the largest group that a manager could potentially have, I am wasting a lot of space in the database. What I would prefer is to have a table that I can use as a member of another table (like I would do in C++ through inheritance) that can be used by the "manager" table to handle the variable number of employees. It might look something like this. CREATE TABLE manager ( name char(50), underlings WORKERS ); CREATE TABLE WORKERS ( name char(50), ); I would like to be able to add a variable number of workers to each manager. Is this possible or am I constrained to enumerating all the possible number of employees even though I will use the full complement only rarely?

    Read the article

  • How do I diagnose a HP Notebook which has hardware issues?

    - by Rob
    My HP DV6t-2300 recently crashed while using FLV Player. It wouldn't start up after this so I had to do a hardware reset (remove power sources, hold down power button ~15 seconds, put back power sources). After this it would turn on, but start up would freeze in Ubuntu, Windows 7, Ubuntu Recovery Mode, and various Linux Live CDs. The only successful way to boot was in Windows 7 Safe Mode. The HP Customer Service was very polite, but they are trying to blame it on a corrupt operating system which is clearly not the case (since I have tried 4 operating systems and none work). I am thinking it might be the GPU since 1) I was watching movies when it crashed and 2) Windows Safe Mode might not use the dedicated GPU. I already ran Memory and HDD tests and there were no detected errors. Any ideas of what's wrong, or suggestions for tests that I should run in safe mode? Should I try reinstalling Windows 7 to convince HP that it's not the OS?

    Read the article

  • Fluent Nhibernate Mapping Single class on two database tables

    - by nabeelfarid
    Hi guys, I am having problems with Mapping. I have two tables in my database as follows: Employee and EmployeeManagers Employee EmployeeId int Name nvarchar EmployeeManagers EmployeeIdFk int ManagerIdFk int So the employee can have 0 or more Managers. A manager itself is also an Employee. I have the following class to represent the Employee and Managers public class Employee { public virtual int Id { get; set; } public virtual string Name { get; set; } public virtual IList<Employee> Managers { get; protected set; } public Employee() { Managers = new List<Employee>(); } } I don't have any class to represent Manager because I think there is no need for it, as Manager itself is an Employee. I am using autoMapping and I just can't figure out how to map this class to these two tables. I am implementing IAutoMappingOverride for overriding automappings for Employee but I am not sure what to do in it. public class NodeMap : IAutoMappingOverride { public void Override(AutoMapping<Node> mapping) { //mapping.HasMany(x => x.ValidParents).Cascade.All().Table("EmployeeManager"); //mapping.HasManyToMany(x => x.ValidParents).Cascade.All().Table("EmployeeManager"); } } I also want to make sure that an employee can not be assigned the same manager twice. This is something I can verify in my application but I would like to put constraint on the EmployeeManager table (e.g. a composite key) so a same manager can not be assigned to an employee more than once. Could anyone out there help me with this please? Awaiting Nabeel

    Read the article

  • 3 Monitors 2 different graphic cards

    - by Michael
    I am looking to add a third monitor to my workstation. I currently have 2 monitors connected to a geforce gt 120. I am wanting to find the cheapest solution on adding another monitor, I have a old ati x300 laying around and wanting to know if I would be able to use that to power the other monitor and if it would conflict with my other graphic card (I am not a gamer). What I want to do is have the at x300 power 1 monitor via dvi and the gt 120 power 2 monitors via vga and dvi. Thanks edit: im running windows 7 64bit

    Read the article

  • Does a portable secondary laptop LCD monitor exist?

    - by Dougnukem
    I'm looking to buy a portable secondary LCD monitor for my Macbook Pro, does anything like that exist? I found some laptops that provide a dual 15'' monitor solution (but it's already baked into the hardware). Also some ideas posted about creating this type of setup back in 2007. I'm looking for something that is as thin as a laptop LCD (with maybe a bulky power supply that I could easily daisy chain or plug into a power strip along with my laptop). How difficult would it be to buy a 17'' laptop screen and hook up a DVI connector and power supply, and build a simple monitor stand for it? I've gotten to used to a dual-monitor setup at work and at home with my laptop that having to use my laptop in single-screen mode makes me feel crippled.

    Read the article

  • Handling undo and edit flag on window with several model objects

    - by Rui Pacheco
    Hi, I've a window that will hold several instances of a model object, listed in a table. The model object is updated using a text view. What is the best way to keep the edit flag and undo manager in synch with the content of the different model objects? I'm thinking creating an instance of the undo manager on the model object and manually set the undo manager for the text view every time the user choses a new model object. Does the undo manager also handle the edited flag?

    Read the article

  • Laptop charger disconnects and reconnects, charger or battery broken?

    - by Rob
    I've got an Acer Aspire One netbook (AOA-150) and there's obviously something wrong with it. The charging port gets VERY HOT and the charger seems to disconnect and reconnect quickly sometimes. This only happens when the netbook is running, and it doesn't seem to care what it's doing other than being on. The battery has an extremely short life (< 30minutes, sometimes) and I almost exclusively run it on the power cable (which needs the battery plugged in. Having it just plugged into the wall won't start up). Does this sound like a problem with the power cable or the battery? The plug for the cable and the port get so hot that if I held them for longer than a few seconds, I'm sure I'd get burnt. EDIT Just got "Popular Question" on this and it WAS the power jack. The ground on it came loose from the board. A bit of solder on it and everything is working great again.

    Read the article

  • Keep lan connection alive while going to sleep

    - by user18151
    Is it possible to keep lan connection alive when going to sleep? Although I would like a laptop independent(in general) answer, my laptop is Thinkpad T500 and the power manager shows in PCI options, the following three option regarding saving link state power: Off, moderate, maximum. Also instant resume apparently does something different, so that isn't much help either. I'm on Windows-7. Here's why: I'm a student, and currently I keep my laptop on almost all the time, but sometimes I sleep it and then I require to check something, so I turn it on. But then internet starts in at least a minute. So I avoid even putting it to sleep. I want that the internet connection should persist, so that I can put it to sleep to avoid power consumption.

    Read the article

  • Graciously shutdown external HDD enclosure?

    - by Jakobud
    I recently purchased a large HDD along with the following HDD enclosure: http://www.newegg.com/Product/Product.aspx?Item=N82E16817173043 It has a simple on-off switch on the back. When I want to turn this thing off, do I simply just flip the switch? I assume the switch simply kills the power to the HDD, but isn't that potentially a bad thing in the case that the HDD is still reading/writing? I used to have a Seagate external HDD and it had a button on the front that I had to hold down for a second or two before it would turn off, but it at least appeared to sort of go through a shutdown procedure where it probably would stop the HDD activity before cutting power. So with this external HDD, I'm a little bit leery about that power switch and understanding exactly what it does. Is this how all HDD enclosures are? EDIT: I'm running the drive in Ubuntu Server. So there is no 'ejecting' the drive lol

    Read the article

  • EMC CX3-10c Fault Condition won;t clear

    - by ITGuy24
    We have an old CX3-10c from Dell that had both Standby Power Supplies (SPS) fail. This obviously caused a fault on the system and disabled the cache. We have replaced the SPS's and they test fine as do all other components. Problem is there is still a fault on the "Enclosure SPE [SPE3]" despite all the component in the enclosure showing as good. I was on the line with Dell Gold support for 3 hours yesterday, they have had me restart the SPs multiple times, as well as reseat the power supplies, even shutdown the system completely and power it back on. All to no avail. Fault remains and cache cannot be re-enabled so long as the Fault is present. Any suggestions on clearing this erroneous fault?

    Read the article

  • How do I pass a bool into locationManager on iphone with stopUpdatingLocation?

    - by user295944
    I want to pass a flag into my location manager function - (void)locationManager:(CLLocationManager *)manager didUpdateToLocation:(CLLocation *)newLocation fromLocation:(CLLocation *)oldLocation so it will look like - (void)locationManager:(CLLocationManager *)manager didUpdateToLocation:(CLLocation *)newLocation fromLocation:(CLLocation *)oldLocation andTweet:(Bool *)tweet but it started with the command [locmanager stopUpdatingLocation]; So how can I pass the bool into the function?

    Read the article

  • Why is hibernation still used?

    - by Moses
    I've never quite understood the original purpose of the Hibernation power state in Windows. I understand how it works, what processes take place, and what happens when you boot back up from Hibernate, but I've never truly understood why it's used. With today's technology, most notably with SSDs, RAM and CPUs becoming faster and faster, a cold boot on a clean/efficient Windows installation can be pretty fast (for some people, mere seconds from pushing the power button). Standby is even faster, sometimes instantaneous. Even SATA drives from 5-6 years ago can accomplish these fast boot times. Hibernation seems pointless to me when modern technology is considered, but perhaps there are applications that I'm not considering. What was the original purpose behind hibernation, and why do people still use it? Edit: I rescind my comment about hibernation being obsolete, as it obviously has very practical applications to laptops and mobile PCs, considering the power restrictions. I was mostly referring to hibernation being used on a desktop.

    Read the article

  • How do I pass a bool into locationManager on iphone with startUpdatingLocation?

    - by user295944
    I want to pass a flag into my location manager function - (void)locationManager:(CLLocationManager *)manager didUpdateToLocation:(CLLocation *)newLocation fromLocation:(CLLocation *)oldLocation so it will look like - (void)locationManager:(CLLocationManager *)manager didUpdateToLocation:(CLLocation *)newLocation fromLocation:(CLLocation *)oldLocation andTweet:(Bool *)tweet but it started with the command [locmanager startUpdatingLocation]; So how can I pass the bool into the function?

    Read the article

  • What do I need to connect a hard disk to my laptop via non powered eSata?

    - by Ludo
    Hi there. I'm looking at getting a hard disk for my laptop (OCZ Vertex 2 SSD) which I would like to connect via eSata. My laptop has an eSata port, but it's not powered (Thinkpad T410). I presume this means I need more than just an eSata to eSata cable as it needs power, so does this mean I need a caddy for the hard disk as well which will provide power to the drive, or do I need one of them eSata cables that has a USB attachment too? I don't think the drive will come with a power supply. I realise this seems simple but I can't find an obvious answer online. Thanks for any assistance! Ludo.

    Read the article

  • help building a PC that can image a dozen hard drives simultaneously

    - by Bigbio2002
    Not sure if this belongs on here or SuperUser, but here goes... I'm trying to figure out how to make a mass hard drive imaging PC out of COTS parts. A dedicated imaging device can do 10 drives at a time, but costs several thousand dollars. So far, I'm thinking to use several 3-port PCI-E Firewire cards, and use some kind of Firewire-to-IDE adapter to connect the drives themselves. The "software" would consist of scripting diskpart, or some other imaging utility. The problem is that I can't seem to find any sort of adapter. I could use standard external hard drive bays, but then I'd have a dozen power cables that I need to plug in. Ugly, messy, and inefficient. I picked Firewire over USB not only for better transfer speeds, but also because FW can deliver power over the bus (and could theoretically power a hard drive). Does anyone have any input on this?

    Read the article

  • Is it my motherboard?

    - by jarodrussell
    Early this week my home server (a Linux machine) threw a kernel panic. Yesterday is happened a couple of times. Then all of a sudden, when I plugged a USB stick in to run a memory test, the monitor stopped coming on. Now whenever I turn it on, the system gets power...I heard the drives spin, I see the processor fan spin, and the hard drive light comes on...but nothing happens. I put a video card in the AGP slot, but still nothing. The light on the power button that usually comes on stopped coming on. I took the memory out to see if it would beep, but nothing beeped. It's like it's getting power, but it's not coming on. Does this sound like a motherboard problem to anyone else? I think it is, but a second opinion would be greatly appreciated. Thanks.

    Read the article

  • Jboss logging issue - pl check this

    - by balaji
    I’m Working as deployer and server administrator. We use Jboss 4.0x AS to deploy our applications. The issue I'm facing is, Whenever we redeploy/restart the server, server.log is getting created but after sometime the logging goes off. Yes it is not at all updating the server.log file. Due to this, we could not trace the other critical issues we have. Actually we have two separate nodes and we do deploy/restarting the server separately on two nodes. We are facing the issue in both of our test and production environment. I could not trace out where exactly the issue is. Could you please help me in resolving the issue? If we have any other issues, we can check the log files. If log itself is not getting updated/logged, how can we move further in analyzing the issues without the recent/updated logs? Below are the logs found in the stdout.log: 18:55:50,303 INFO [Server] Core system initialized 18:55:52,296 INFO [WebService] Using RMI server codebase: http://kl121tez.is.klmcorp.net:8083/ 18:55:52,313 INFO [Log4jService$URLWatchTimerTask] Configuring from URL: resource:log4j.xml 18:55:52,860 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasRBPFTraceLogger without a class name. 18:55:52,860 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasRBPFMessageLogger without a class name. 18:55:54,273 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasCacheTraceLogger without a class name. 18:55:54,274 ERROR [STDERR] LOG0026E The Log Manager cannot create the object AmasCacheMessageLogger without a class name. 18:55:54,334 ERROR [STDERR] LOG0026E The Log Manager cannot create the object JACCTraceLogger without a class name. 18:55:54,334 ERROR [STDERR] LOG0026E The Log Manager cannot create the object JACCMessageLogger without a class name. 18:55:56,059 INFO [ServiceEndpointManager] WebServices: jbossws-1.0.3.SP1 (date=200609291417) 18:55:56,635 INFO [Embedded] Catalina naming disabled 18:55:56,671 INFO [ClusterRuleSetFactory] Unable to find a cluster rule set in the classpath. Will load the default rule set. 18:55:56,672 INFO [ClusterRuleSetFactory] Unable to find a cluster rule set in the classpath. Will load the default rule set. 18:55:56,843 INFO [Http11BaseProtocol] Initializing Coyote HTTP/1.1 on http-0.0.0.0-8180 18:55:56,844 INFO [Catalina] Initialization processed in 172 ms 18:55:56,844 INFO [StandardService] Starting service jboss.web Please help..

    Read the article

  • mysql select column from view problem

    - by haim evgi
    i create a view table like : CREATE VIEW ViewManager AS SELECT us.UserId AS 'Account Manager', ......... after that, when i run a query to select data from this view like : SELECT 'Account Manager' , .. from ViewManager then the data i get in this column is the text 'Account Manager' and not the value of the this columns. Is there a way to solve this ? Of course I can change the field name , but i want to know if there is another solution, thanks.

    Read the article

< Previous Page | 166 167 168 169 170 171 172 173 174 175 176 177  | Next Page >