Search Results

Search found 14157 results on 567 pages for 'drive failure'.

Page 174/567 | < Previous Page | 170 171 172 173 174 175 176 177 178 179 180 181  | Next Page >

  • Can I take my ReadyNAS drive in Raid1 and plug it straight into new different machine?

    - by jacko
    I would assume that I can just take my HDD out of my NAS (in raid1 mirror) and plug it into another enclosure and have it work off the bat but I'd like to make sure... Any ideas? Edit: My current setup is a Netgear ReadyNAS in (hardware) raid1. I'm hoping to replace this with a home theatre type PC (possibly running Ubuntu), and would like to migrate my data without having to do a bulk transfer over my network between the 2 machines. Can anyone confirm the case for the Netgear ReadyNAS? Edit: Ok after further reading it seems that the ReadyNAS Duo formats my drive as ext3 in 16k blocks. There are instructions for mounting a drive into a linux box here: Mounting Sparc-based ReadyNAS Drives in x86-based Linux There is also talk about a linux image here: ReadyNAS Data Recovery - VMware recovery tool I'm not sure whether this means they ReadyNAS actually implements software raid under the hood, or what? So it appears like it IS do-able, but do any of you linux guru's know whether this is viable and whether the fact that they are in raid 1 affect matters?

    Read the article

  • Can any iSCSI NAS appliance replicate / clone a LUN to an external drive?

    - by Boden
    I would like to backup using Windows Imaging to some kind of NAS appliance. I believe this will require the NAS to support iSCSI. I would then like the appliance to support the replication of the iSCSI LUN to an external eSATA or USB disk connected directly to the appliance. I've found plenty of NAS appliances that can do iSCSI and replicate to an external drive, but none that I've found thus far can do both at once. That is, the devices can do iSCSI, but then the replication feature doesn't work. The idea here is to backup to an appliance located in a secure office far away from the server room. Offsite backups to external hard drive could be managed from the appliance. The benefits of such a setup would be: 1) very unlikely that fire or random theft would affect both server-room backup and "remote" backup appliance 2) offsite backups could be managed by multiple trusted people without granting access to server room 3) Windows imaging provides poor man's deduplication, so each backup volume can contain a decent backup history. I understand why this would be a non-trivial thing to implement, but I'm wondering if such a thing exists? Preferably a tabletop, low to medium cost device. Alternative solutions welcome. NOTE: I'm backing up very few but very large files, so file replication is not a good option.

    Read the article

  • SSD as primary or secondary drive on a small Linux server?

    - by Alex Martelli
    I'm pensioning off my 10-years-old home server and replacing it with an Ubuntu 10.04 box. The two storage devices are a Western Digital Caviar Green 2.0TB HD and an Intel X25-M 34nm Gen 2 80GB SATA II 2.5inch SSD (the box has 8GB RAM and an i5 750, if it matters). I don't care much about boot times (since I don't plan to reboot all that often;-); the main frequent, performance-demanding task will be (re)building large open source C or C++ software packages from sources (as an open source contributor, I do that often). So, I thought I'd keep the SSD as the secondary drive and the HD as the primary one, using the SSD mostly for the files that can otherwise demand a lot of seeking (esp. in a parallel make). However, the friendly vendor (perhaps more experienced in Windows systems than in Linux ones) thinks the "normal" way to configure the machine would be with the SSD as the primary drive. I'm pretty rusty on configuring and tuning systems, so, I thought I'd better double check on SuperUser... thanks in advance for advice about this choice!

    Read the article

  • Is there a Mac utility that does low level drive integrity check and repair?

    - by Puzzled Late at Night
    The PGP Whole Disk Encryption for Mac OS X Quick Start User Guide version 10.0 contains the following remarks: PGP Corporation deliberately takes a conservative stance when encrypting drives, to prevent loss of data. It is not uncommon to encounter Cyclic Redundancy Check (CRC) errors while encrypting a hard disk. If PGP WDE encounters a hard drive with bad sectors, PGP WDE will, by default, pause the encryption process. This pause allows you to remedy the problem before continuing with the encryption process, thus avoiding potential disk corruption and lost data. To avoid disruption during encryption, PGP Corporation recommends that you start with a healthy disk by correcting any disk errors prior to encrypting. and As a best practice, before you attempt to use PGP WDE, use a third-party scan disk utility that has the ability to perform a low-level integrity check and repair any inconsistencies with the drive that could lead to CRC errors. These software applications can correct errors that would otherwise disrupt encryption. The PGP WDE Windows user guide suggests SpinRite or Norton Disk Doctor. What recourse do I have on the Mac?

    Read the article

  • Can I use HP Recovery Discs for a different hard drive capacity and make?

    - by Fasih Khatib
    About two years ago I created HP Recovery Discs (3 of them). Now my hard drive has crashed and new one is still a week from delivery. I was reading up on how to reinstall the genuine OS using the Recovery Discs as i was not given any Windows 7 installation discs. I did my bit of research after getting answers from the community on what these discs do and found out on other sites that people experience issues when recovering their OS from the disc. Especially when they change the make or capacity of the harddrive. Unfortunately I had to change the make as the hard drive that came built in has gone out of production. This question is just a part of my checklist to avoid problems when recovering the OS. I have: HP DV4-2126TX (available only in India I guess) I had: Seagate Momentus 320 GB I ordered: Western Digital Scorpio Black 500 GB Windows 7 Home Premium 32-bit Is there a possibility to encounter any problems due to the changed capacity and make? I only want my genuine OS and drivers – not my data. I was told that Disc 1 contained the OS and drivers, and the rest of the discs contained data. I couldn't verify that.

    Read the article

  • How can I recover my data from a damaged hard drive?

    - by krk
    a few days ago when I was working on windows my laptop was beaten on the side where the hard drive is located. As a result, it was damaged and I couldn't access the windows partition. I had to boot the linux one, which is working without any trouble. I have 2 partition formatted with ntfs, the one with windows on it, and the other one intended to store data. I mounted the windows partition from ubuntu and I could see all my files. But when I tried to mount the data partition it was impossible. It threw me an error, it couldn't recognize ntfs partition. I try to copy the damaged disk into an external hard drive using the command: dd if=/dev/sda of=/dev/sdb conv=noerror,sync The progress stopped at 60%. I was still unable to mount the data partition. Now I'm trying to backup my files using an utility called Photorec. The problem is that it is recovering my files in a disorderly way, it is all mixed up and I need my original directory structure, it will become an endless task to organize the files as they were before. Is there any way I can get my partition back?

    Read the article

  • Best format for hard drive for Windows and Mac?

    - by Neil
    I have a 500 GB USB External Hard Drive. I need four partitions on it, for the following purposes: 160 GB for a bootable backup of my Mac. 160 GB for a bootable backup of my Windows. 11 GB for a bootable Snow Leopard Install Disk Rest as for file storage. Now I need a partition table which will get recognised on both Windows and Mac, without needing extra software on Windows, which will let me keep bootable copies of both OS'es, but let me access the file storage from both OS'es. Currently, I have a GUI Partition Table, with Mac OS Extended (Journaled) Partitions for the two backups, Mac OS Extended for the Install Disk, and NTFS for the file storage. While this gets recognised perfectly on my Mac, thanks to an NTFS for Mac driver from Paragon, when connected to Windows, the drive is detected by the machine (listed in Safely Remove USB), but not recognised in Windows Explorer unless I install MacDrive, which is not feasible for me to install on public Windows Machines I might wanna access my storage area on. Can someone recommend the best combination of formats and software/drivers to get this done seamlessly?

    Read the article

  • What is the best free program to burn DVD movies from DVD movie files that are present on the hard drive the way ImgBurn does it in Windows?

    - by cipricus
    Evaluating burning programs is difficult: it takes more time, while errors are very unpleasant. I have looked at AcetoneISO, Brasero, and K3B (which many recommend) but they seem more limited than Nero, CDBurnXP and especially ImgBurn from Windows. They all seem to work (did not tested them fully myself) but at a more basic level (create ISO, burn them, etc.). When it comes to something like creating a DVD movie disk from DVD movie files present on the hard drive, it seems to me that I would have to create the ISO first and then burn it, which involves using more hard drive space and more time. Looking in the Windows direction, there is a Nero for Linux. It costs money. ImgBurn is said to work well in Wine, but as yet I have not tested it enough. What other options are there?

    Read the article

  • Trying to debug a 'Assertion failure in -[UIActionSheet showInView:]' error....

    - by dsobol
    I am working through "Beginning iPad Application Development" and am getting hung up in Chapter 3 where I have created a project that works with an Action Sheet. As it stands now, my application loads into the simulator just fine with no errors that I am aware of, but as it runs, it crashes with the following errors showing up in the debugger window: 2010-05-31 19:44:39.703 UsingViewsActionSheet[49538:207] * Assertion failure in -[UIActionSheet showInView:], /SourceCache/UIKit_Sim/UIKit-1145.66/UIAlert.m:7073 2010-05-31 19:44:39.705 UsingViewsActionSheet[49538:207] * Terminating app due to uncaught exception 'NSInternalInconsistencyException', reason: 'Invalid parameter not satisfying: view != nil' I am sure that this is the block where the app breaks based upon my use of breakpoints. //Implement viewDidLoad to do additional setup after loading the view, typically from a nib. - (void)viewDidLoad { UIActionSheet *action = [[UIActionSheet alloc] initWithTitle:@"This is my Action Sheet!" delegate:self cancelButtonTitle:@"OK" destructiveButtonTitle:@"Delete Message!" otherButtonTitles:@"Option 1", @"Option 2", @"Option 3", nil]; [action showInView:self.view]; // <-- This line seems to trigger the crash.... [action release]; [super viewDidLoad]; } Am I missing something obvious, or is there more to the problem than is shown here? I have looked at the abstract for showInView and cannot divine anything there yet. I appreciate any and all asssitance. Regards, Steve O'Sullivan

    Read the article

  • How can I get JUnit test (driven from Ant script) to dump the stack of exception that causes failure

    - by Matt Wang
    We run JUnit test from Ant script, as follows. When the test failed, I expect it to output the stack dump of the exception that casuses the failure, but it doesn't. Is there any trick to get it dumped? <target description="Run JUnit tests" name="run-junit" depends="build-junit"> <copy file="./AegisLicense.txt" tofile="test/junit/classes/AegisLicense.txt" overwrite="true"/> <junit printsummary="yes" haltonfailure="no" fork="yes" forkmode="once" failureproperty="run-aegis-junit-failed" showoutput="yes" filtertrace="off"> <classpath refid="Aegisoft.testsupport.classpath"/> <classpath> <pathelement location="test/junit/classes"/> </classpath> <batchtest> <fileset dir="test/junit/src"> <include name="**"/> </fileset> </batchtest> </junit> <fail

    Read the article

  • How do I trace SQL Server Failure Audit events?

    - by Tim Perry
    I recently took over management of a Windows 2003 server. The application log is being filled up with messages like these: Event Type: Failure Audit Event Source: MSSQLSERVER Event Category: (4) Event ID: 18456 Date: 3/5/2010 Time: 4:00:30 PM User: N/A Computer: FAIROAKS1 Description: Login failed for user 'administrator'. [CLIENT: <local machine>] Data: 0000: 18 48 00 00 0e 00 00 00 .H...... 0008: 0a 00 00 00 46 00 41 00 ....F.A. 0010: 49 00 52 00 4f 00 41 00 I.R.O.A. 0018: 4b 00 53 00 31 00 00 00 K.S.1... 0020: 07 00 00 00 6d 00 61 00 ....m.a. 0028: 73 00 74 00 65 00 72 00 s.t.e.r. 0030: 00 00 .. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. I'd like to figure out what program is causing these. Is there a way to trace and find out which process is causing these errors?

    Read the article

  • BizTalk Server 2009 - Architecture Options

    - by StuartBrierley
    I recently needed to put forward a proposal for a BizTalk 2009 implementation and as a part of this needed to describe some of the basic architecture options available for consideration.  While I already had an idea of the type of environment that I would be looking to recommend, I felt that presenting a range of options while trying to explain some of the strengths and weaknesses of those options was a good place to start.  These outline architecture options should be equally valid for any version of BizTalk Server from 2004, through 2006 and R2, up to 2009.   The following diagram shows a crude representation of the common implementation options to consider when designing a BizTalk environment.         Each of these options provides differing levels of resilience in the case of failure or disaster, with the later options also providing more scope for performance tuning and scalability.   Some of the options presented above make use of clustering. Clustering may best be described as a technology that automatically allows one physical server to take over the tasks and responsibilities of another physical server that has failed. Given that all computer hardware and software will eventually fail, the goal of clustering is to ensure that mission-critical applications will have little or no downtime when such a failure occurs. Clustering can also be configured to provide load balancing, which should generally lead to performance gains and increased capacity and throughput.   (A) Single Servers   This option is the most basic BizTalk implementation that should be considered. It involves the deployment of a single BizTalk server in conjunction with a single SQL server. This configuration does not provide for any resilience in the case of the failure of either server. It is however the cheapest and easiest to implement option of those available.   Using a single BizTalk server does not provide for the level of performance tuning that is otherwise available when using more than one BizTalk server in a cluster.   The common edition of BizTalk used in single server implementations is the standard edition. It should be noted however that if future demand requires increased capacity for a solution, this BizTalk edition is limited to scaling up the implementation and not scaling out the number of servers in use. Any need to scale out the solution would require an upgrade to the enterprise edition of BizTalk.   (B) Single BizTalk Server with Clustered SQL Servers   This option uses a single BizTalk server with a cluster of SQL servers. By utilising clustered SQL servers we can ensure that there is some resilience to the implementation in respect of the databases that BizTalk relies on to operate. The clustering of two SQL servers is possible with the standard edition but to go beyond this would require the enterprise level edition. While this option offers improved resilience over option (A) it does still present a potential single point of failure at the BizTalk server.   Using a single BizTalk server does not provide for the level of performance tuning that is otherwise available when using more than one BizTalk server in a cluster.   The common edition of BizTalk used in single server implementations is the standard edition. It should be noted however that if future demand requires increased capacity for a solution, this BizTalk edition is limited to scaling up the implementation and not scaling out the number of servers in use. You are also unable to take advantage of multiple message boxes, which would allow us to balance the SQL load in the event of any bottlenecks in this area of the implementation. Any need to scale out the solution would require an upgrade to the enterprise edition of BizTalk.   (C) Clustered BizTalk Servers with Clustered SQL Servers   This option makes use of a cluster of BizTalk servers with a cluster of SQL servers to offer high availability and resilience in the case of failure of either of the server types involved. Clustering of BizTalk is only available with the enterprise edition of the product. Clustering of two SQL servers is possible with the standard edition but to go beyond this would require the enterprise level edition.    The use of a BizTalk cluster also provides for the ability to balance load across the servers and gives more scope for performance tuning any implemented solutions. It is also possible to add more BizTalk servers to an existing cluster, giving scope for scaling out the solution as future demand requires.   This might be seen as the middle cost option, providing a good level of protection in the case of failure, a decent level of future proofing, but at a higher cost than the single BizTalk server implementations.   (D) Clustered BizTalk Servers with Clustered SQL Servers – with disaster recovery/service continuity   This option is similar to that offered by (C) and makes use of a cluster of BizTalk servers with a cluster of SQL servers to offer high availability and resilience in case of failure of either of the server types involved. Clustering of BizTalk is only available with the enterprise edition of the product. Clustering of two SQL servers is possible with the standard edition but to go beyond this would require the enterprise level edition.    As with (C) the use of a BizTalk cluster also provides for the ability to balance load across the servers and gives more scope for performance tuning the implemented solution. It is also possible to add more BizTalk servers to an existing cluster, giving scope for scaling the solution out as future demand requires.   In this scenario however, we would be including some form of disaster recovery or service continuity. An example of this would be making use of multiple sites, with the BizTalk server cluster operating across sites to offer resilience in case of the loss of one or more sites. In this scenario there are options available for the SQL implementation depending on the network implementation; making use of either one cluster per site or a single SQL cluster across the network. A multi-site SQL implementation would require some form of data replication across the sites involved.   This is obviously an expensive and complex option, but does provide an extraordinary amount of protection in the case of failure.

    Read the article

  • What might cause https failure when not specifying SSL protocol?

    - by user35042
    I have a VBScript program that retrieves a web page from a server not under my control. The URL looks something like https://someserver.xxx/index.html. I use this code to create the object that does the page getting: Set objWinHttp = CreateObject("WinHttp.WinHttpRequest.5.1") When I wrote my program it had no problem retrieving this page. Recently, the web server serving this page went through an upgrade. Now my program can no longer fetch the page. Some clues: Clue 1. I can fetch the web page if I use a browser (I tried Firefox, IE, and Chrome). Clue 2. The VBScript code yields this error: The message received was unexpected or badly formatted. Clue 3. I can fetch the web page from the command line in certain cases but not in others: curl --sslv3 -v -k 'https://someserver.xxx/index.html' # WORKS! curl --sslv2 -v -k 'https://someserver.xxx/index.html' # WORKS! curl -v -k 'https://someserver.xxx/index.html' # FAILS curl --tlsv1 -v -k 'https://someserver.xxx/index.html' # FAILS In the case where I do not specify a protocol I get this error: * SSLv3, TLS handshake, Client hello (1): * error:14077417:SSL routines:SSL23_GET_SERVER_HELLO:sslv3 alert illegal parameter * Closing connection #0 In the case where I specify --tlsv1 I get this error: * SSLv3, TLS handshake, Client hello (1): * SSLv3, TLS alert, Server hello (2): * error:14094417:SSL routines:SSL3_READ_BYTES:sslv3 alert illegal parameter * Closing connection #0 A. Does anyone have any suggestions or ideas on what might be going on at the web server end (I am unable to talk to the admins of the web server to find out what they changed). B. Is there a way I can change my VBScript code to work around this issue? Can the SSL version be forced?

    Read the article

  • How can I resolve Oracle 11g XE connection failure straight after installation?

    - by d3vid
    I have just installed Oracle 11g XE on a Windows 7 VirtualBox VM, using all the default options. "Getting Started" fails When I click on Getting Started I get taken to http://127.0.0.1:8080/apex/f?p=4950 which fails. After some browsing I came across a suggestion to confirm the HTTP port, but I can't get this far, because I can't connect. connect system fails If I select Run SQL command line I get taken to a SQL prompt. I enter connect system and get prompted for a password. I enter the password. I immediately get the following error: ERROR: ORA-01033: ORACLE initialization or shutdown in progress Process ID: 0 Session ID: 0 Serial number: 0 Info: Start database This happens whether or not I run Start database first. (Start database just opens a Windows command prompt window.) Info: Windows services My Oracle services start as follows: Starting the manual services doesn't resolve the problem. Enabling and starting the disabled service doesn't resolve the problem. Is there something I haven't done? How can I resolve this connection error?

    Read the article

  • Which file system to use for portable hard drive shared among different operating systems?

    - by Jonathon Watney
    Something similar has been asked already but my criteria is a little different. I need to share a portable hard drive (USB/Firewire) between Mac OSX, Linux and Windows XP systems where the files being shared are sometimes 4GB. Is there a file system that is available out of the box on all these operating systems that support this and allows read/write access? If not, what's the next best solution in terms of installing additional software on these operating systems?

    Read the article

  • Grub rescue: unknown filesystem erro while booting from USB

    - by Dilip Kumar
    I'm currently using ubuntu 12.04 which has grub2 and wanted to install windows 8 from my USB, i also created a bootable usb flash drive using windows 7 dvd download tool, the problem is - I formatted my hard drive and whenever i try to boot from the flash drive i get an error "error: unknown filesystem" and gives grub rescue prompt, since my dvd drive is not working the only way for me to install win8 is from USB,can anybody help me with this?

    Read the article

  • Cannot run a VM with more than three network interfaces with KVM

    - by Bostonvaulter
    I'm running KVM on top of Ubuntu 10.10 Server I can create VM's (Virtual Machine) and network interfaces fine but I cannot seem to add more than three network interfaces. As soon as I have a VM with four network interfaces it gets stuck on startup at the starting SeaBIOS page with this message: Starting SeaBIOS (version pre-0.6.1-20100702_143500-palmer) So far I've verified this with two VM's, a Ubuntu 10.10 desktop and a Vyatta router. The specific network hardware I assign to the VM's doesn't seem to matter. I'm trying to have one bridged interface and three private networks using Vyatta to route between them. Does anyone know why I can't run a VM with more than three network interfaces? Edit: Additionally the KVM thread responsible for the specific VM hangs using ~100% CPU (i.e. one core). Here's the command for the process that is hanging: /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 512 -smp 1,sockets=1,cores=1,threads=1 -name vyatta -uuid 6dff7c94-6810-423e-5fea-fec10da0e9b7 -nodefaults -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/vyatta.monitor,server,nowait -mon chardev=monitor,mode=readline -rtc base=utc -boot c -drive file=/home/rams/virtual-machines/vyatta.img,if=none,id=drive-ide0-0-0,boot=on,format=raw -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -device rtl8139,vlan=0,id=net0,mac=00:54:00:be:cc:4b,bus=pci.0,addr=0x3 -net tap,fd=97,vlan=0,name=hostnet0 -device rtl8139,vlan=1,id=net1,mac=52:54:00:da:59:ed,bus=pci.0,addr=0x5 -net tap,fd=98,vlan=1,name=hostnet1 -device rtl8139,vlan=2,id=net2,mac=52:54:00:ce:22:b6,bus=pci.0,addr=0x6 -net tap,fd=99,vlan=2,name=hostnet2 -device rtl8139,vlan=3,id=net3,mac=52:54:00:1e:bc:46,bus=pci.0,addr=0x7 -net tap,fd=101,vlan=3,name=hostnet3 -chardev pty,id=serial0 -device isa-serial,chardev=serial0 -usb -vnc 127.0.0.1:0 -k en-us -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 Edit: I've also found an error in dmesg that might be related (it also shows up when running virtd in verbose mode): 14:47:24.399: warning : qemudParsePCIDeviceStrs:1422 : Unexpected exit status '1', qemu probably failed I've also tried disabling app armor but that doesn't seem to make a difference.

    Read the article

  • mint linux, DVD drive keeps randomly being accessed. unsure how to find culprit

    - by juicebox
    I have a workstation with mint linux 12. It seems like the DVD drive on the machine keeps randomly "activating". By activating it makes noise, the light turns on, and it seems like it is checking if a disk is in it. At first I thought I was being hacked and someone/something was trying to check if I had media in the DVDRom drive. I ruled that out with netstat and rkhunter. I checked my logs and the only thing I can find that might help point out the problem are these repeated chunks in syslog: Mar 24 17:47:31 rich-MINT kernel: [ 9846.551422] ata2.00: cmd a0/00:00:00:08:00/00:00:00:00:00/a0 tag 0 pio 16392 in Mar 24 17:47:31 rich-MINT kernel: [ 9846.551424] res 51/40:01:00:00:00/00:00:00:00:00/a0 Emask 0x10 (ATA bus error) Mar 24 17:47:31 rich-MINT kernel: [ 9846.551427] ata2.00: status: { DRDY ERR } Mar 24 17:47:31 rich-MINT kernel: [ 9846.551433] ata2.00: hard resetting link Mar 24 17:47:32 rich-MINT kernel: [ 9846.868012] ata2.01: hard resetting link Mar 24 17:47:32 rich-MINT kernel: [ 9847.344054] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 310) Mar 24 17:47:32 rich-MINT kernel: [ 9847.344067] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 24 17:47:32 rich-MINT kernel: [ 9847.376118] ata2.00: configured for PIO0 Mar 24 17:47:32 rich-MINT kernel: [ 9847.393047] ata2.01: configured for UDMA/133 Mar 24 17:47:32 rich-MINT kernel: [ 9847.397046] ata2: EH complete and again Mar 24 17:55:28 rich-MINT kernel: [10323.633268] sr 1:0:0:0: ioctl_internal_command return code = 8000002 Mar 24 17:55:28 rich-MINT kernel: [10323.633270] : Sense Key : Aborted Command [current] [descriptor] Mar 24 17:55:28 rich-MINT kernel: [10323.633275] : Add. Sense: No additional sense information Mar 24 17:55:11 rich-MINT kernel: [10306.640009] ata2.00: link is slow to respond, please be patient (ready=0) Mar 24 17:55:16 rich-MINT kernel: [10310.840009] ata2.00: SRST failed (errno=-16) Mar 24 17:55:16 rich-MINT kernel: [10310.840016] ata2.00: hard resetting link Mar 24 17:55:16 rich-MINT kernel: [10311.160013] ata2.01: hard resetting link Mar 24 17:55:16 rich-MINT kernel: [10311.636061] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 310) Mar 24 17:55:16 rich-MINT kernel: [10311.636075] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 24 17:55:16 rich-MINT kernel: [10311.668122] ata2.00: configured for PIO0 Mar 24 17:55:16 rich-MINT kernel: [10311.684854] ata2.01: configured for UDMA/133 Mar 24 17:55:17 rich-MINT kernel: [10312.105473] ata2: EH complete (Copied from Pastebin - http://pastebin.com/YNDrnyzH) If any linux masters could take a quick look at these log outputs and help me understand what is going on , much appreciated.

    Read the article

  • How to troubleshoot a remote wmi query/access failure?

    - by Roman
    Hi I'm using Powershell to query a remote computer in a domain for a wmi object, eg: "gwmi -computer test -class win32_bios". I get this error message: Value does not fall within the expected range Executing the query local under the same user works fine. It seems to happen on both windows 2003 and also 2008 systems. The user that runs the shell has admin rights on the local and remote server. I checked wmi and dcom permissions as far as I know how to do this, they seem to be the same on a server where it works, and another where it does not. I think it is not a network issue, all ports are open that are needed, and it also happens within the same subnet. When sniffing the traffic we see the following errors: RPC: c/o Alter Cont Resp: Call=0x2 Assoc Grp=0x4E4E Xmit=0x16D0 Recv=0x16D0 Warning: GssAPIMechanism is not found, either caused by not reassembled, conversation off or filtering. And an errormessage from Kerberos: Kerberos: KRB_ERROR - KDC_ERR_BADOPTION (13) The option code in the packet is 0x40830000 Any idea what I should look into?

    Read the article

  • Can an SATA hard drive image be restored onto an SSD?

    - by Bryan Parker
    I'm currently using an SATA hard drive on my primary dev machine, but planning to upgrade to an SSD at some point soon. I use TrueImage on a regular basis to make backups, and to upgrade my harddrive without reinstalling everything. Will I be able to restore and boot onto an SSD? Will there be a performance hit or other issues to watch out for?

    Read the article

  • libvirt qemu/kvm migration problem

    - by Panda
    I am using kvm and libvirt on my Dell server. Now i am trying to migrate one virtual machine from a physical server to another. However, I failed everytime. In virsh on physicalServer1, I typed: virsh # migrate virtualmachine1 qemu+ssh://username@physicalServer2/system error: operation failed: migration to 'tcp:physicalServer2:49163' failed: migration failed Then I searched FAQ part on libvirt.org. It says: error: operation failed: migration to '...' failed: migration failed This is an error often encountered when trying to migrate with QEMU/KVM. This typically happens with plain migration, when the source VM cannot connect to the destination host. You will want to make sure your hosts are properly configured for migration (see the migration section of this FAQ) I managed to ssh physicalServer2 from a shell on virtualmachine1 so the above red part did not explain my failure. I also open ports on physicalServer2, iptables -L shows following information: Chain INPUT (policy ACCEPT) target prot opt source destination ACCEPT udp -- anywhere anywhere udp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:domain ACCEPT udp -- anywhere anywhere udp dpt:bootps ACCEPT tcp -- anywhere anywhere tcp dpt:bootps ACCEPT udp -- anywhere anywhere udp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:domain ACCEPT udp -- anywhere anywhere udp dpt:bootps ACCEPT tcp -- anywhere anywhere tcp dpt:bootps ACCEPT tcp -- anywhere anywhere state NEW tcp dpts:49152:49215 Chain FORWARD (policy ACCEPT) target prot opt source destination ACCEPT all -- anywhere 192.168.122.0/24 state RELATED,ESTABLISHED ACCEPT all -- 192.168.122.0/24 anywhere ACCEPT all -- anywhere anywhere REJECT all -- anywhere anywhere reject-with icmp-port-unreachable REJECT all -- anywhere anywhere reject-with icmp-port-unreachable ACCEPT all -- anywhere 192.168.122.0/24 state RELATED,ESTABLISHED ACCEPT all -- 192.168.122.0/24 anywhere ACCEPT all -- anywhere anywhere REJECT all -- anywhere anywhere reject-with icmp-port-unreachable REJECT all -- anywhere anywhere reject-with icmp-port-unreachable Chain OUTPUT (policy ACCEPT) target prot opt source destination The /var/log/libvirt/qemu/virtualmachine1.log on physicalServer2: 2011-05-06 13:37:30.708: starting up LC_ALL=C PATH=/usr/local/sbin:/usr/local/bin:/usr/bin:/usr/sbin:/sbin:/bin QEMU_AUDIO_DRV=none /usr/bin/kvm -S -M pc-0.14 -enable-kvm -m 2048 -smp 1,sockets=1,cores=1,threads=1 -name openjudge-test -uuid a8c704bc-a4f9-90db-3e57-40e60b00aac1 -nodefconfig -nodefaults -chardev socket,id=charmonitor,path=/var/lib/libvirt/qemu/virtualmachine1.monitor,server,nowait -mon chardev=charmonitor,id=monitor,mode=readline -rtc base=utc -boot c -drive file=/media/nfs/virtualmachine1.img,if=none,id=drive-ide0-0-0,format=raw -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -netdev tap,fd=20,id=hostnet0 -device rtl8139,netdev=hostnet0,id=net0,mac=00:16:36:8a:22 :a0,bus=pci.0,addr=0x3 -chardev pty,id=charserial0 -device isa-serial,chardev=charserial0,id=serial0 -usb -vnc 127.0.0.1:2 -vga cirrus -incoming tcp:0.0.0.0:49163 -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 char device redirected to /dev/pts/0 2011-05-06 13:37:30.915: shutting down The /var/log/libvirt/qemu/virtualmachine1.log on physicalServer1 is empty. Both physical servers are using Ubuntu 11.04. The libvirt and kvm used are installed by apt-get. The libvirt version is 0.8.8.

    Read the article

  • How to customize Windows Failover clustering to trigger on failure of custom window service?

    - by melaos
    i'm a total newbie on windows failover clustering. and what i want to do now is to setup the FC (failover clustering) on two win 2008 R2 server. and right now i have my custom window service running on both machine. But they cannot run concurrently as it will mess up the DB, thus i just want one to be available at all time (high availability). so i'm wondering if there's any way to set the failover policy to include this custom window service that i've installed on these machines so that if this service goes down or die, then it will automatically trigger the failover to the second node. is this possible? or must it be done programatically? and if so what is the best way? thanks ~m

    Read the article

  • Failure to install NetFX3 on Windows Server 2012: Error 3017 -- Am I missing something here?

    - by Nick
    I am really struggling to get this installed. I have tried the suggestions here in an attempt to rectify any possible corruption. I mounted the disk image to 'G' to do an offline install. I also attempted an online install with similar results. Output as follows: Microsoft Windows [Version 6.2.9200] (c) 2012 Microsoft Corporation. All rights reserved. C:\Users\Administrator>dism /online /enable-feature /featurename:NetFX3 /All /So urce:G:\sources\sxs /LimitAccess Deployment Image Servicing and Management tool Version: 6.2.9200.16384 Image Version: 6.2.9200.16384 Enabling feature(s) [==========================100.0%==========================] Error: 3017 The requested operation failed. A system reboot is required to roll back changes made. The DISM log file can be found at C:\Windows\Logs\DISM\dism.log Log as follows (Errors/Warnings Only): 2013-04-08 23:40:17, Error DISM DISM Package Manager: PID=3756 TID=3768 Failed finalizing changes. - CDISMPackageManager::Internal_Finalize(hr:0x80070bc9) 2013-04-08 23:40:17, Error DISM DISM Package Manager: PID=3756 TID=3768 Failed processing package changes with session options - CDISMPackageManager::ProcessChangesWithOptions(hr:0x80070bc9) 2013-04-08 23:40:17, Error DISM DISM Package Manager: PID=3756 TID=3768 Failed ProcessChanges. - CPackageManagerCLIHandler::Private_ProcessFeatureChange(hr:0x80070bc9) 2013-04-08 23:40:17, Error DISM DISM Package Manager: PID=3756 TID=3768 Failed while processing command enable-feature. - CPackageManagerCLIHandler::ExecuteCmdLine(hr:0x80070bc9) 2013-04-08 23:40:17, Error DISM DISM.EXE: DISM Package Manager processed the command line but failed. HRESULT=80070BC9 2013-04-08 23:38:10, Warning DISM DISM Provider Store: PID=3160 TID=3172 Failed to Load the provider: C:\Windows\TEMP\505F54F1-4977-4233-835C-8B6DA83BCAEB\PEProvider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x8007007e) 2013-04-08 23:39:23, Warning DISM DISM Provider Store: PID=3756 TID=3768 Failed to Load the provider: C:\Users\ADMINI~1\AppData\Local\Temp\2\F1B7A223-F380-4F42-84BF-396D374EE80B\PEProvider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x8007007e) 2013-04-08 23:39:23, Warning DISM DISM Provider Store: PID=3756 TID=3768 Failed to Load the provider: C:\Users\ADMINI~1\AppData\Local\Temp\2\F1B7A223-F380-4F42-84BF-396D374EE80B\IBSProvider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x8007007e) 2013-04-08 23:39:23, Warning DISM DISM Provider Store: PID=3756 TID=3768 Failed to get the IDismObject Interface - CDISMProviderStore::Internal_LoadProvider(hr:0x80004002) 2013-04-08 23:39:23, Warning DISM DISM Provider Store: PID=3756 TID=3768 Failed to Load the provider: C:\Users\ADMINI~1\AppData\Local\Temp\2\F1B7A223-F380-4F42-84BF-396D374EE80B\Wow64provider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x80004002) 2013-04-08 23:39:23, Warning DISM DISM Provider Store: PID=3756 TID=3768 Failed to Load the provider: C:\Users\ADMINI~1\AppData\Local\Temp\2\F1B7A223-F380-4F42-84BF-396D374EE80B\EmbeddedProvider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x8007007e) None of my error codes align with any of those on this MS support page. I would really appreciate your assistance. I am really struggling with a solution. Am I missing something obvious here? EDIT: I have verified the checksum of my ISO image: File Name: en_windows_server_2012_x64_dvd_915478.iso SHA1: D09E752B1EE480BC7E93DFA7D5C3A9B8AAC477BA

    Read the article

  • SOS, i erased a disk,1T.by mistake

    - by gabriel
    i tried to make bootable a flash drive from the startup disk creator, and i wanted to copy an iso of the 11.10 ubuntu, and when i tried to erase the flash drive i pressed erase on another removable drive 1T storage by mistake, VVVery very very quickly less than one second and with no warning everything was erased i suppose.Is that thing possible?When i tried before theis to erase the flash drive it took around a minute to erase the 8GB.But now less than a second for 1T? Please help, Gabriel

    Read the article

  • Mac OS X printing to CUPS - More intuitive authentication failure?

    - by Moduspwnens
    We have a network-wide CUPS server that offers authenticated printer access to all our campus users. We've been pretty disappointed with the way Mac clients handle bad printing authentication, though. In any other authentication dialog, when a user types in a bad username or password, the window shakes briefly, allowing the user to re-enter. With printers, this isn't the case. It'll happily accept (and even save to the keychain, if specified) bad credentials. The authentication dialog is dismissed, and the user then has to deal with the print jobs showing up as "On hold (authentication required)". To get their job printed, they need to select it in the printer's queue, click "Resume", then re-enter appropriate credentials. Is there a way to get failed printing authentication to work more intuitively for Mac OS X clients? We're trying to support a BYOD environment, but our end users have been really confused by this. It's made even worse by the way it pre-populates the user's full login name (e.g. "Smith, John"), which tends to make them think to use their local machine passwords.

    Read the article

< Previous Page | 170 171 172 173 174 175 176 177 178 179 180 181  | Next Page >