Search Results

Search found 21659 results on 867 pages for 'welcome always'.

Page 176/867 | < Previous Page | 172 173 174 175 176 177 178 179 180 181 182 183  | Next Page >

  • Copy/Pasting data from SQL Server to Excel splits up text into multiple columns?

    - by Paul
    I've got a problem pasting data from the result grid of SQL Server 2005 to an excel 2007 spreadsheet. I have a query in SQL Server that returns 2 columns (a number column and a text column) On one computer here i can happily copy (right-click copy) and then just right-click and paste into an excel spreadsheet. no problem. On another computer here when i try and paste into excel it splits the text column up and pastes the text into multiple columns based on spaces between words. For example if one of the rows has... Paste me please ...in it then when pasting into excel it splits the text and pastes each work into a seperate column within excel. We've tried comparing options in both SQL Server & excel with the computer it works fine on but can see no differences. Any ideas welcome Thanks

    Read the article

  • DIrect videos and slideshows fullscreen from another display

    - by neurino
    I have 3 displays: 1 control display I can see 2 40" Full HD displays I can't see my need is to play videos and presentations fullscreen on the two 40" screens while being able to control them from the control display. So far I am able to achieve this with a cumbersome set of keyboard shortcuts like: open VLC on control display send to left display with Win + Shift + Left go fullscreen with f and more combinations to restore, get VLC on control display etc. This is really error prone and not professional. Also I wish I have a media player and a slideshow player that can: send the same video / slideshow to the two 40" displays at the same time send two different videos / slideshows, one each 40" display having all controls on the central display, the only one I can see. Any advice welcome, thank you for your support.

    Read the article

  • DNS problems : correct nameserver, namserver working, but not resolving

    - by user1719624
    My problem is as follows. Any suggestions are welcome. [domain].org is not resolving whois and checking the registry information shows that the correct nameserver is set. The primary nameserver is also the server on which domain.org is hosted. The primary nameserver is also used for a number of other domains, and is working fine for those. Logging into the server, I can ping [domain].org and it resolves correctly. Setting the nameserver as my own DNS server on my laptop, and the URL resolves correctly. If the domain has the correct nameserver set, and the nameserver can resolve the URL to the correct IP address, and if I use the nameserver as my DNS then it resolves correctly, AND the nameserver is used for other domains which are resolving correctly, then why isn't it working? NB : this is a new domain registration and has been set up for around 10 days now, so it's not simple slow propagation. Any ideas? thanks

    Read the article

  • Hack/software to easily move screen mapping of a wacom tablet?

    - by Riyaah
    I would like to move/manipulate the mapping of my Wacom tablet to my screen as easily as with Inklet: http://tenonedesign.com/inklet.php Is anyone aware of any software or hack to acheive this on Mac OS X? If not I'm thinking about trying to write a script that centers the mapping on the current cursor position, and then bidning that to a button on my tablet. Combined with a script for toggling between fullscreen/part of screen-mapping that should be enough. My idea so far is to edit the .prefs file since it's plain XML, and then restart the tablet driver. But any pointers relating to this would be most welcome, since my knowledge of this kind of things is rudimentary.

    Read the article

  • DVD/CD-ROM drives stop working in Windows 7

    - by Marcus L
    All of a sudden Windows 7 (64 bit) lost all DVD and CD-ROM drives. It worked fine for about a month, then I don't know what happened. At first I thought it was a hardware problem - that my DVD-ROM had malfunctioned. But then I realized that Windows 7 no longer picked up on Demon Tools drives either. I can boot both Windows installation and Knoppix from the DVD-drive. So it seems to be a general problem with "disc-media". When trying to reinstall the hardware DVD-ROM Windows recognizes the drive (though sometimes simply label it as "CD-ROM drive"), but then says something went wrong - with from what I understand is a default error message (39), claiming the driver has become corrupt. I've tried every Microsoft recommended action, i.e. uninstall, reinstall, look for driver updates etc. etc., but with no luck. Any tip most welcome!

    Read the article

  • Logs show lots of user attempts from unknown IP

    - by rodling
    I lost access to my instance which I host on AWS. Keypairing stopped to work. I detached a volume and attached it to a new instance and what I found in logs was a long list of Nov 6 20:15:32 domU-12-31-39-01-7E-8A sshd[4925]: Invalid user cyrus from 210.193.52.113 Nov 6 20:15:32 domU-12-31-39-01-7E-8A sshd[4925]: input_userauth_request: invalid user cyrus [preauth] Nov 6 20:15:33 domU-12-31-39-01-7E-8A sshd[4925]: Received disconnect from 210.193.52.113: 11: Bye Bye [preauth] Where "cyrus" is changed by hundreds if not thousands of common names and items. What could this be? Brute force attack or something else malicious? I traced IP to Singapore, and I have no connection to Singapore. May thought is that this was a DoS attack since I lost access and server seemed to stop working. Im not to versed on this, but ideas and solutions for this issue are welcome.

    Read the article

  • Issues with new graphics card and drivers

    - by Ortund
    With my onboard graphics card (Intel HD 4000) I was able to use 1680x1050 screen resolution. Using the same screen and an Asus ENGTS250 graphics card with 296.10 drivers installed, I'm not able to use that resolution anymore. Also, I've been having other trouble with driver installations. Using 340.52 or 337.88, I can't boot into Windows 7. I see the Windows Welcome screen and then the screen goes black, loses signal and the computer locks up. I think the drivers issues and the resolution problems go hand-in-hand. I have a feeling I could use a newer driver than 296.10 which would give me access to use the 1680x1050 resolution I want to use, but I'm terrified that if I update or install another driver, that the computer will lock up again. Can anyone recommend a [better] driver for me to use?

    Read the article

  • What's better for deploying a website + DB on EC2: 2 small VM or a large one?

    - by devguy
    I'm planning the deployment of a mid-sized website with a SQL Server Standard DB. I've chosen Amazon EC2 to deploy it. I now have to choose between these 2 options: 1) get 2 small instances (1 core each, 1.7 GB of ram each): one for the IIS front-end, one for running the DB. Note: these "small instances" can only run the 32-bit version of Win2008 Server 2) a single large instance (4 cores, 7.5 gb of ram) where I'd install both IIS and the SQL Server. Note: this large instance can only run the 64-bit version of Win2008 Server What's better in terms on performance, scalability, ease of management (launch up a new instance while I backup the principal instance) etc. All suggestions and points of view are welcome!

    Read the article

  • DBD::CSV: Problem with userdefined functions

    - by sid_com
    From the SQL::Statement::Functions documentation: Creating User-Defined Functions ... More complex functions can make use of a number of arguments always passed to functions automatically. Functions always receive these values in @_: sub FOO { my( $self, $sth, $rowhash, @params ); } #!/usr/bin/env perl use 5.012; use warnings; use strict; use DBI; my $dbh = DBI->connect( "DBI:CSV:", undef, undef, { RaiseError => 1, } ); my $table = 'wages'; my $array_ref = [ [ 'id', 'number' ], [ 0, 6900 ], [ 1, 3200 ], [ 2, 1800 ], ]; $dbh->do( "CREATE TEMP TABLE $table AS import( ? )", {}, $array_ref ); sub routine { my $self = shift; my $sth = shift; my $rowhash = shift; # return $_[0] / 30; }; $dbh->do( "CREATE FUNCTION routine" ); my $sth = $dbh->prepare( "SELECT id, routine( number ) AS result FROM $table" ); $sth->execute(); $sth->dump_results(); When I try this I get an error-message: DBD::CSV::st execute failed: Use of uninitialized value $_[0] in division (/) at ./so.pl line 27. [for Statement "SELECT id, routine( number ) AS result FROM "wages""] at ./so.pl line 34. When I comment out the third argument I works as expected ( because it looks as if the third argument is missing ): #!/usr/bin/env perl ... sub routine { my $self = shift; my $sth = shift; #my $rowhash = shift; return $_[0] / 30; }; ... 0, 230 1, 106.667 2, 60 3 rows Is this a bug?

    Read the article

  • Questions on Juval Lowy's IDesign C# Coding Standard

    - by Jan
    We are trying to use the IDesign C# Coding standard. Unfortunately, I found no comprehensive document to explain all the rules that it gives, and also his book does not always help. Here are the open questions that remain for me (from chapter 2, Coding Practices): No. 26: Avoid providing explicit values for enums unless they are integer powers of 2 No. 34: Always explicitly initialize an array of reference types using a for loop No. 50: Avoid events as interface members No. 52: Expose interfaces on class hierarchies No. 73: Do not define method-specific constraints in interfaces No. 74: Do not define constraints in delegates Here's what I think about those: I thought that providing explicit values would be especially useful when adding new enum members at a later point in time. If these members are added between other already existing members, I would provide explicit values to make sure the integer representation of existing members does not change. No idea why I would want to do this. I'd say this totally depends on the logic of my program. I see that there is alternative option of providing "Sink interfaces" (simply providing already all "OnXxxHappened" methods), but what is the reason to prefer one over the other? Unsure what he means here: Could this mean "When implementing an interface explicitly in a non-sealed class, consider providing the implementation in a protected virtual method that can be overridden"? (see Programming .NET Components 2nd Edition, end of chapter “Interfaces and Class Hierarchies”). I suppose this is about providing a "where" clause when using generics, but why is this bad on an interface? I suppose this is about providing a "where" clause when using generics, but why is this bad on a delegate?

    Read the article

  • How to avoid Remove-Item PowerShell errors "process cannot access the file"?

    - by Michael Freidgeim
    We are using TfsDeployer and PowerShell script to remove the folders ising Remove-Item before deployment of a new version. Sometimes the PS script failed with the error Remove-Item : Cannot remove item Services\bin: The process cannot access the file Services\bin' because it is being used by another proc Get-ChildItem -Path $Destination -Recurse | Remove-Item <<<< -force -recurse + CategoryInfo : WriteError: (C:\Program File..\Services\bin:DirectoryInfo) [Remove-Item], IOException FullyQualifiedErrorId : RemoveFileSystemItemIOError,Microsoft.PowerShell.Commands.RemoveItemCommand I’ve tried to follow the answer from PowerShell remove force to pipe get-childitem -recurse into remove-item. get-childitem * -include *.csv -recurse | remove-item ,but the error still happens periodically. We are using unlocker to manually kill locking application, (it’s usually w3wp), but I prefer to find automated solution. Another (not ideal) option is to-suppress-powershell-errors get-childitem -recurse -force -erroraction silentlycontinue Any suggestions are welcome.

    Read the article

  • How to verify if my copy operation is complete in Windows 7?

    - by Tim
    Yesterday, I was leaving some job of copying a directory to run overnight. This morning however, I found the computer had restarted because of Windows Update or something. I was wondering if there is some way to check if the copy is complete? One way I guess would be check the last modified time of the copy, and when the system restarted. But I was wondering where to find the time when the system restarted? I was also wondering if where to find some logging files that have the records. I know Event Viewer, but don't know where to find within it. Other methods are welcome too. I also would like to hear suggestions for other ways to accomplish the copy instead of just simple copy and paste. Thanks and regards!

    Read the article

  • How to boot directly into an application

    - by denonth
    I have an application that I want to boot in directly when windows xp starts. So after that "welcome" screen I don't want to see anything and load directly into the app. How can I do that? I tried adding a exe file to startup folder. But he is loading some 2-3 thing and then my app and I see windows desktop normally. Is it possible to load it directly? It is a windows form application not an cmd.

    Read the article

  • How to expand Raid 5 on ICH10 - Gigabyte ex58-ds4?

    - by NeverEatAlone
    I was wondering if there is a relatively simple way to expand my HD space. My setup is 4 x 640 GB drives. Motherboard has 4 ports on 1 controller and 2 ports on another controller, however they cant be joined. I would like to somehow get more store space in raid configuration. One scenario that I can see working is replacing one 640 drive for a 2TB drive. Waiting for Raid to rebuild. Rinse and repeat. However, I have no idea if I would be able to even see/access the new space. All alternatives / ideas are welcome. Thank you

    Read the article

  • Application process never terminates on each run

    - by rockyurock
    I am seeing an application always remains live even after closing the application using my Perl script below. Also, for the subsequent runs, it always says that "The process cannot access the file because it is being used by another process. iperf.exe -u -s -p 5001 successful. Output was:" So every time I have to change the file name $file used in script or I have to kill the iperf.exe process in the Task Manager. Could anybody please let me know the way to get rid of it? Here is the code I am using ... my @command_output; eval { my $file = "abc6.txt"; $command = "iperf.exe -u -s -p 5001"; alarm 10; system("$command > $file"); alarm 0; close $file; }; if ($@) { warn "$command timed out.\n"; } else { print "$command successful. Output was:\n", $file; } unlink $file;

    Read the article

  • Problem with Google Calendar API "getTimes()" method

    - by Raffo
    I'm trying to get several informations from google calendar's API in JAVA. While trying to access to informations about the time of an event I got a problem. I do the following: CalendarService myService = new CalendarService("project_name"); myService.setUserCredentials("user", "pwd"); URL feedUrl = new URL("http://www.google.com/calendar/feeds/default/private/full"); CalendarQuery q = new CalendarQuery(feedUrl); CalendarEventFeed resultFeed = myService.query(q, CalendarEventFeed.class); for (int i = 0; i < resultFeed.getEntries().size(); i++) { CalendarEventEntry g = resultFeed.getEntries().get(i); List<When> t = g.getTimes(); //other operations } The list t obtained with getTimes() on a CalendarEventEntry is always empty and I can't figure out why. This seems strange to me since for a calendar event it should always exist a description of when it should happen... what am I missing??

    Read the article

  • Which is better Span that runat server or default asp lable ?

    - by Space Cracker
    I have a simple asp.net web page that contain a table with about 5 TR and each row have 2 TD .. in the page load I get user data ( 5 property ) and view them in this page the following are first 2 rows : <table> <tr> <td> FullName </td> <td> <span id="fullNameSpan" runat="server"></span> </td> </tr> <tr> <td> Username </td> <td> <span id="userNameSpan" runat="server"></span> </td> </tr> </table> I always used <asp:Label to set value by code but i always notice that label converted in runtime to span so i decided to user span by making him runat=server to be accessed by code, so Which is better to use asp:label or span with runat=server ??

    Read the article

  • Help with Corrupt version of IE8 on WinXPsp3

    - by Anon
    I've upgrade from IE6 to 7 to 8 and back down and back up, but still have critical issues in IE such as * cannot see any version info in "about internet explorer" * cannot run windows update * cannot load SharePoint pages (and other pages using ActiveX or IE-specific dhtml) I've also re-installed sp3, but still no luck. Also, also - I've changed security settings to be most permissive. Next step is blowing it all away and starting with windows7. Short of that, any suggestions are welcome. Thanks in advance.

    Read the article

  • em.createQuery keeps returning null

    - by Developer106
    I have this application which i use JSF 2.0 and EclipseLink, i have entities created for a database made in MySQL, Created these entities using netbeans 7.1.2, it gets created automaticly. Then i use session beans to work with these entities, the thing is the em.createQuery always returns a null, though I checked NamedQueries in the entities and they perfectly match a sample from the entities named queries:- @NamedQueries({ @NamedQuery(name = "Users.findAll", query = "SELECT u FROM Users u"), @NamedQuery(name = "Users.findByUserId", query = "SELECT u FROM Users u WHERE u.userId = :userId"), @NamedQuery(name = "Users.findByUsername", query = "SELECT u FROM Users u WHERE u.username = :username"), @NamedQuery(name = "Users.findByEmail", query = "SELECT u FROM Users u WHERE u.email = :email"), notice how i use this findByEmail query in the session bean :- public Users findByEmail(String email){ em.getTransaction().begin(); String find = "Users.findByEmail"; Query query = em.createNamedQuery(find); query.setParameter("email", email); Users user = (Users) query.getSingleResult(); but it always returns null from this em.createNamedQuery, i tried using .createQuery first but it also was no good. the stacktrace of the exception Caused by: java.lang.NullPointerException at com.readme.entities.sessionBeans.UsersFacade.findByEmail(UsersFacade.java:48) at com.readme.user.signup.SignupBean.checkAvailability(SignupBean.java:137) at com.readme.user.signup.SignupBean.save(SignupBean.java:146) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:57) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43) at java.lang.reflect.Method.invoke(Method.java:601) What Seems To Be The Problem Here ?

    Read the article

  • What C# container is most resource-efficient for existence for only one operation?

    - by ccornet
    I find myself often with a situation where I need to perform an operation on a set of properties. The operation can be anything from checking if a particular property matches anything in the set to a single iteration of actions. Sometimes the set is dynamically generated when the function is called, some built with a simple LINQ statement, other times it is a hard-coded set that will always remain the same. But one constant always exists: the set only exists for one single operation and has no use before or after it. My problem is, I have so many points in my application where this is necessary, but I appear to be very, very inconsistent in how I store these sets. Some of them are arrays, some are lists, and just now I've found a couple linked lists. Now, none of the operations I'm specifically concerned about have to care about indices, container size, order, or any other functionality that is bestowed by any of the individual container types. I picked resource efficiency because it's a better idea than flipping coins. I figured, since array size is configured and it's a very elementary container, that might be my best choice, but I figure it is a better idea to ask around. Alternatively, if there's a better choice not out of resource-efficiency but strictly as being a better choice for this kind of situation, that would be nice as well.

    Read the article

  • Mac PPC_7100 ROM for SheepShaver?

    - by Good_quess
    Hello everybody, I still own a PPC 7100/80av, that I bought in early 1995. The Mac is still running fine, but I am not using it often these days. I recently came across SheepShaver and would like to take my old games and apps to the emulation. For SheepShaver I would like to use a copy of my 7100's ROM. Did anybody succeed in saving a working copy of this machines ROM? I tried CopyRom and GetRom, but all I ever saved was a 4MB file good for nothing. I am just wondering what I am missing. Any ideas would be very welcome. Thank you!

    Read the article

  • UpdatePanel reloads the whole page

    - by Emil D
    Hi.I'm building an asp.net cutom control inside which I have two dropdownlists: companyIdSelection and productFamilySelection.I populate the companyIdSelection at Page_Load and in order to populate the productFamilySelection depending on the selected item in companyIdSelection.I'm using UpdatePanels to achieve this, but for some reason every time I update companyIdSelection Page_Load is being called ( which as far as I know should happen only when the entire page is reloaded ), the list is being reloaded again and the item the user selected is lost( the selected item is always the top one ).Here's the code <asp:UpdatePanel ID="updateFamilies" runat="server" UpdateMode="Always"> <ContentTemplate> Company ID:<br> <br></br> <asp:DropDownList ID="companyIdSelection" runat="server" AutoPostBack="True" OnSelectedIndexChanged="companyIdSelection_SelectedIndexChanged"> </asp:DropDownList> <br></br> Product Family: <br></br> <asp:DropDownList ID="productFamilySelection" runat="server" AutoPostBack="True" onselectedindexchanged="productFamilySelection_SelectedIndexChanged"> </asp:DropDownList> <br> </ContentTemplate> </asp:UpdatePanel> protected void Page_Load(object sender, EventArgs e) { this.companyIdSelection.DataSource = companyIds(); //companyIds returns the object containing the initial data items this.companyIdSelection.DataBind(); } protected void companyIdSelection_SelectedIndexChanged(object sender, EventArgs e) { // Page_Load is called again for some reason before this method is called, so it // resets the companyIdSelection EngDbService s = new EngDbService(); productFamilySelection.DataSource = s.getProductFamilies(companyIdSelection.Text); productFamilySelection.DataBind(); } Also, I tried setting the UpdateMode of the UpdatePanel to "Conditional" and adding an asyncpostback trigger but the result was the same. What am I doing wrong? PS: I fixed the updating problem, by using Page.IsPostBack in the Page_Load method, but I would still want to avoid a full postback if possible

    Read the article

  • Recursive code Sorting in VB

    - by Peter
    Ages old question: You have 2 hypothetical eggs, and a 100 story building to drop them from. The goal is to have the least number of guaranteed drops that will ensure you can find what floor the eggs break from the fall. You can only break 2 eggs. Using a 14 drop minimum method, I need help writing code that will allow me to calculate the following: Start with first drop attempt on 14th floor. If egg breaks then drop floors 1-13 to find the floor that causes break. ElseIf egg does not break then move up 13 floors to floor number 27 and drop again. If egg breaks then drop floors 15-26 starting on 15 working up to find the floor egg breaks on. ElseIf egg does not break then move up 12 floors to floor number 39 and drop again. etc. etc. The way this increases is as follows 14+13+12+11+10+9+8+7+6+5+4+3+2+1 So always adding to the previous value, by one less. I have never written a sorting algorithm before, and was curious how I might go about setting this up in a much more efficient way than a mile long of if then statements. My original idea was to store values for the floors in an array, and pull from that, using the index to move up or down and subtract or add to the variables. The most elegant solution would be a recursive function that handled this for any selected floor, 1-100, and ran the math, with an output that shows how many drops were needed in order to find that floor. Maximum is always 14, but some can be done in less.

    Read the article

  • Javascript: click and dblclick deliver different parentNodes on same html. Why?

    - by user1658206
    currently I work on an very small wysiwyg editor based on jquery. I dont care about IE oder Chrome, just Firefox. My problem is to find if the selection is in a link for to get the value of the href attribute if is set. With click the node of the link is found, with double click always the body. It is in designMode. My event-handler for click and dblclick. The vars current_selection, current_node, iframe and container are global. selection_handler:function() { current_selection = iframe.getSelection(); current_node = current_selection.anchorNode; if(current_node.nodeName == "#text") { current_node = current_node.parentNode; } $('#log').text(current_node.nodeName); }, The log shows mit for example 'body', when I click in unformated text. When I add a link with execCommand('createLink',...) the log shows 'A'. That works. When I mark the linked word with 2 click from start to end, the log shows 'A'. But with double click I always get 'body'. So I can't get the href attribute. The handler is defined in the init: init:function(options) { ... iframe = $('#wysiwyg-'+container.attr('id'))[0].contentWindow; iframe.addEventListener('dblclick',methods.selection_handler,false); iframe.addEventListener('click',methods.selection_handler,false); ... } Has somebody an idea what is wrong?

    Read the article

  • Testifying that somaxconn change can make a difference

    - by petermolnar
    I got into an argument on the net.core.somaxconn parameter: I was told that it will not make any difference if we change the default 128. I believed this might be enough proof: "If the backlog argument is greater than the value in /proc/sys/net/core/somaxconn, then it is silently truncated to that value" http://linux.die.net/man/2/listen but it's not. So does anyone know a method to testify this with two machines, one running, for example MySQL or LVS and the other is hammering it in a GBit network? I'm opened to any solution, scripts are slightly more welcome.

    Read the article

< Previous Page | 172 173 174 175 176 177 178 179 180 181 182 183  | Next Page >