Search Results

Search found 14212 results on 569 pages for 'video production'.

Page 217/569 | < Previous Page | 213 214 215 216 217 218 219 220 221 222 223 224  | Next Page >

  • Grayed-Out Sleep and Hibernate Options on Windows 7 After Updating Graphics Driver

    - by Maxim Zaslavsky
    I have a Gateway M275 Tablet PC, on which I've installed Windows 7 Ultimate. The laptop is quite old, so there aren't any Win7 drivers for it, not to mention any Vista drivers. Win7 has been working for some time, but I noticed that my video output wasn't working. I went into Device Manager and found that I didn't have a driver for my video card: it just recognized it as the standard one. I searched online and found an XP driver for it, released by Gateway. Device Manager accepted this driver and prompted me to reboot. After that, I noticed that my Sleep and Hibernate options in the Shut Down menu have been grayed-out. I looked online and found that many people are attributing this to display drivers, as such an old driver would surely not be compatible with the standby procedures Windows 7 uses. To make it clear: I was able to Sleep and Hibernate before updating the drivers; now, I can't. Running powercfg /a gives me, "An internal system component has disabled this standby state," for each available standby mode. Is there some way that the driver can be modified to support hibernation? The new driver fixed my video output problem, but I guess hibernation is more important for me. If not, what steps should I take to remove the driver and just leave the standard Windows one, which previously supported hibernation and sleep on this computer? Thanks in advance.

    Read the article

  • USB-to-Serial showing gibberish at 115200 Baud

    - by Mose
    I've got a serious problem which drives me crazy because I tried everything I could think of. First of all, I made a video: http://youtu.be/boghkuq7L_s but please read the following text for more information, not only view the video! When using a USB-to-Serial interface everything works as long as I don't go beyond 57600 Baud. At higher rates I only get giberish like this: év.­b0JNLYÆÿ¿iëd0U²(kßÞb! ú]/xscB!ï¯!BoXûÿ1ïâÖCÿ6ÌAnè*íÌC)º¿BíÞØ.C.@ÆÃwHJÂs "YE:ñ.èFðÌCÊ÷ÞÄ !x H w6@BtbHJ ̪ Ì6ì H¾a¿bH.">îvy®;f<ßBÌ p­L¨fæH­E ­þ¼MBÞI What makes the problem so strange is, I exchanged every component and the problem still presists. I tried differtent OSes (Ubuntu, WinXP, Win7, OSX 10.7) with 32 and 64 Bit. I tried USB-to-Serial interface from FTDI and Prolific. I tried reading the output from my Raspberry PI and from an Asterisk Appliance. I changed the cables and the wiring. Nothing helped. In the video I made a example with a old Notebook with native COM and put the USB-to-Serial to the same connection as "sniffer" (only Rx and GND connected) to make sure the output and everything is ok as one can see on the native port. The voltage is ok. Settings for both are 115200 Baud, 8 Bit with 1 Stop and no flow control. Native is ok. USB is messed up. I used the newest drivers and double checked all connections. I have no idea what is wrong here. As I couldn't find anyone describing problems like this I question my long experiance in computer science and think I'm doing some completly wrong... Please help :-/

    Read the article

  • Grayed-Out Sleep and Hibernate Options on Windows 7 After Updating Graphics Driver

    - by Maxim Z.
    I have a Gateway M275 Tablet PC, on which I've installed Windows 7 Ultimate. The laptop is quite old, so there aren't any Win7 drivers for it, not to mention any Vista drivers. Win7 has been working for some time, but I noticed that my video output wasn't working. I went into Device Manager and found that I didn't have a driver for my video card: it just recognized it as the standard one. I searched online and found an XP driver for it, released by Gateway. Device Manager accepted this driver and prompted me to reboot. After that, I noticed that my Sleep and Hibernate options in the Shut Down menu have been grayed-out. I looked online and found that many people are attributing this to display drivers, as such an old driver would surely not be compatible with the standby procedures Windows 7 uses. To make it clear: I was able to Sleep and Hibernate before updating the drivers; now, I can't. Running powercfg /a gives me, "An internal system component has disabled this standby state," for each available standby mode. Is there some way that the driver can be modified to support hibernation? The new driver fixed my video output problem, but I guess hibernation is more important for me. If not, what steps should I take to remove the driver and just leave the standard Windows one, which previously supported hibernation and sleep on this computer? Thanks in advance.

    Read the article

  • Windows 7 x64 support for Intel GMA 3650 (or GMA 3600)

    - by Loom
    I recently purchased an Intel D2700 MUD motherboard and I cannot find drivers for the Win7 x64 integrated graphics (Intel GMA 3650 aka PowerVR sgs545). The accompanying CD contains Win7 x32 version only. When I run it I got an error: This computer does not meet the minimum requirements for installing the software. I tried to use online utility Intel Driver Update Utility Graphics. I used Chrome, Firefox, Internet Explorer without success. First, UAC prompt appear, and then endlessly spinning progress-bar with text "Analyzing computer...". The text in UAC prompt is: Program file name: System Requirements Lab Verified publisher: Husdawg, LLC I downloaded this utility (intel_srldetect_4.5.5.0) and started it from my hard disk. I got an error: A network error occured while attempting to read from the file: C:\Users\Loom\Downloads\SystemRequirementsLab_intel_4.5.5.0.msi Standard VGA driver works for this video card but without hardware acceleration: Hardware acceleration is either disabled or not supported by your video card driver, which could slow game performance. Make sure you have the latest video card driver installed and that hardware acceleration is turned on. Where I can get appropriate driver?

    Read the article

  • Intel HD Graphics vs NVIDIA Quadro FX 380 PCI-E

    - by Michael
    I recently purchased an Acer Veriton which has an i5-650 processor, Windows 7 Pro (64 bit) and Intel HD Graphics listed as the video card. I also purchased a PNY nVIDIA Quadro FX 380 PCI-E card for improved picture and home video viewing and editing. I have already replaced the original 300 wattt power supply to a 430 watt Antec Truepower I had on hand and boosted the RAM to 8 gigs from the original 4. Question 1) Am I getting any improvement in visual quality or system speed with the Quadro or is it a waste of money and I should just save up to buy a bigger video card? This card was on sale for $115. If I am getting improvement then I need to ask another question. Question 2) Instructions for the Quadro installation are as follows... 1--Uninstall the existing VGA driver. -Remove the existing Display Driver via "Add or Remove Porgrams". -Shut down your computer. 2--Remove your Existing Graphics Board (or Disable Integrated 3D Graphics Controller). skipping instructions on how to remove existing graphics board -Systems with integrated (also know as on-board) 3D graphics may require you to disable the integrated 3D graphics system. Consult the owners or vendor manual that came with your PC on how to properly do this. So is the Intel HD Graphics considered a 3D graphics controller? If so should I just contact Acer or can anyone give me instructions? Thanks in advance for any help.

    Read the article

  • Constant crashes in windows 7 64bit when playing games

    - by yx.
    I've tried everything I can possibly think of in trying to fix this problem and I'm totally out of ideas, so any help would be appreciated: The problem: whenever I fire up a game, it works for a short while with no problems and then it would crash. Either its a hard crash, forcing me to reboot, or windows would report that the display driver has stopped working and recovered. Here is a list of things I've already tried: Drivers - tried the latest drivers (catalyst 9.12) as well as the stock drivers that came with the video card. Also have the latest BIOS/chipset Memtest - Ran Memtest86+ overnight, had no problems, the windows diagnostic tool also does not find any problems. Overheating - Video card/cpu temperatures are well below peak (42 and 31 Celsius receptively) PSU Voltage - CPUID shows that the voltage levels are all above what they should be. The PSU itself is only roughly 16 months old and is a good model. HDD - No errors when checked GPU - Brand new (replaced previous card since I thought it was the problem, apparently not) Overclocking - Everything is at stock levels, memory voltage is set to manufacturer's standard Specs: Motherboard: ASUS P5Q Pro CPU: Core 2 Duo E8400 3.0 ghz OS: Windows 7 home premium 64 bit Memory: Mushkin Enhanced 4GB DDR2 GPU: Sapphire HD 5850 1GB PSU: SeaSonic M12 600W ATX12V DirectX: DX11 Event Viewer after a crash always has these logged: A fatal hardware error has occurred. Reported by component: Processor Core Error Source: Machine Check Exception Error Type: Bus/Interconnect Error Processor ID: 1 The details view of this entry contains further information. A fatal hardware error has occurred. Reported by component: Processor Core Error Source: Machine Check Exception Error Type: Bus/Interconnect Error Processor ID: 0 The details view of this entry contains further information. A previous card that I had (4850x2) also had these errors, so I changed video cards, but the same thing is happening.

    Read the article

  • Can anyone help me make my reverse proxy actually cache?

    - by Lenary
    Hi folks, I'm trying to configure a Reverse Caching Proxy but so far have had no luck. I would preferrably like to use apache (that will be all it will be used for), but am open to solutions using other software that can also run on Mac OS X 10.6 (I have also tried using Varnish and Squid, but with no more luck). We're running a system with about 80 mac mini clients that will be requesting lots of video from a server. To reduce load, we thought we could use Apache (which comes on the macs by default) to cache this video forever (or at least as long as possible) onto the macs' disks. I have managed to get a reverse proxy set up with apache using ProxyPass etc, but when i tried to add CacheEnable disk / to the configuration, nothing happened (i do have mod_disk_cache included). Can anyone help with my issue? The apache config file is here Thanks in advance Edit: So far I have been testing it with smaller text files, and it hasn't been caching properly. This suggests it is nothing to do with us actually downloading video, but actually to do with the cache configuration.

    Read the article

  • sybase bcp import fails

    - by chromeplatedbanana
    We're trying to export some tables from our production database to our test database using bcp. The bcp export seems to work fine, but the import always fails with a data type error (see below). We tested on our test database exporting the table content to a file, then importing it in again immediately, but that failed too. e.g., bcp TABLENAME out ~/tempfile -S servername -U username generates a file as expected. If we use -c option then the number of lines is as expected. However, bcp TABLENAME in ~/tempfile -S servername -U username fails with CTLIB Message: - L0/0D/S0/N0/0/0: blk_int(): blk_layer: CT library error: Cannot find an equivalent CS_TYPE for this TDS data type 49 blk_init failed. We get this whenever we try to copy into TABLENAME, whether from the production or test table dump file. I don't understand why export and import for the same TABLENAME is generating a data type error. What am I doing wrong here? Thanks

    Read the article

  • Module configuration and layout configuration in zend framework.

    - by Prasanth P
    Hi all, I got some codes from other articles for configuring module and layout in zend framework. I tried with in my local. i didn't get different layout for default and admin module. Here is my code for configuring module and layout for zend framework. configs/application.ini [production] # Debug output phpSettings.display_startup_errors = 0 phpSettings.display_errors = 0 # Include path includePaths.library = APPLICATION_PATH "/../library" # Bootstrap bootstrap.path = APPLICATION_PATH "/Bootstrap.php" bootstrap.class = "Bootstrap" admin.bootstrap.path = APPLICATION_PATH "/modules/admin/Bootstrap.php" admin.bootstrap.class = "admin_Bootstrap" # Front Controller resources.frontController.controllerDirectory = APPLICATION_PATH "/controllers" resources.frontController.env = APPLICATION_ENV # Session resources.session.name = "ZendSession" resources.session.save_path = APPLICATION_PATH "/../data/session" resources.session.remember_me_seconds = 86400 # Layout resources.layout.layout = "layout" resources.layout.layoutPath = APPLICATION_PATH "/layouts" admin.resources.layout.layout = "admin" admin.resources.layout.layoutPath = APPLICATION_PATH "/modules/admin/layouts" # Views resources.view.encoding = "UTF-8" resources.view.basePath = APPLICATION_PATH "/views/" resources.view[] = resources.frontController.moduleDirectory = APPLICATION_PATH "/modules" resources.modules[] = resources.view[] = admin.resources.view[] = [staging : production] [testing : production] phpSettings.display_startup_errors = 1 phpSettings.display_errors = 1 [development : production] phpSettings.display_startup_errors = 1 phpSettings.display_errors = 1 application/Bootstrap.php <?php /** * Ensure all communications are managed by sessions. */ require_once ('Zend/Session.php'); Zend_Session::start(); class Bootstrap extends Zend_Application_Bootstrap_Bootstrap { protected function _initDoctype() { $this->bootstrap( 'view' ); $view = $this->getResource( 'view' ); $view->navigation = array(); $view->subnavigation = array(); $view->headTitle( 'Module One' ); $view->headLink()->appendStylesheet('/css/clear.css'); $view->headLink()->appendStylesheet('/css/main.css'); $view->headScript()->appendFile('/js/jquery.js'); $view->doctype( 'XHTML1_STRICT' ); //$view->navigation = $this->buildMenu(); } /*protected function _initAppAutoLoad() { $autoloader = new Zend_Application_Module_Autoloader(array( 'namespace' => 'default', 'basePath' => APPLICATION_PATH )); return $autoloader; }*/ protected function _initLayoutHelper() { $this->bootstrap('frontController'); $layout = Zend_Controller_Action_HelperBroker::addHelper( new ModuleLayoutLoader()); } public function _initControllers() { $front = Zend_Controller_Front::getInstance(); $front->addModuleDirectory(APPLICATION_PATH . '/modules/admin/', 'admin'); } protected function _initAutoLoadModuleAdmin() { $autoloader = new Zend_Application_module_Autoloader(array( 'namespace' => 'Admin', 'basePath' => APPLICATION_PATH . '/modules/admin' )); return $autoloader; } protected function _initModuleutoload() { $autoloader = new Zend_Application_Module_Autoloader ( array ('namespace' => '', 'basePath' => APPLICATION_PATH ) ); return $autoloader; } } class ModuleLayoutLoader extends Zend_Controller_Action_Helper_Abstract // looks up layout by module in application.ini { public function preDispatch() { $bootstrap = $this->getActionController() ->getInvokeArg('bootstrap'); $config = $bootstrap->getOptions(); echo $module = $this->getRequest()->getModuleName(); /*echo "Configs : <pre>"; print_r($config[$module]);*/ if (isset($config[$module]['resources']['layout']['layout'])) { $layoutScript = $config[$module]['resources']['layout']['layout']; $this->getActionController() ->getHelper('layout') ->setLayout($layoutScript); } } } application/modules/admin/Bootstrap.php <?php class Admin_Bootstrap extends Zend_Application_Module_Bootstrap { /*protected function _initAppAutoload() { $autoloader = new Zend_Application_Module_Autoloader(array( 'namespace' => 'admin', 'basePath' => APPLICATION_PATH . '/modules/admin/' )); return $autoloader; }*/ protected function _initDoctype() { $this->bootstrap( 'view' ); $view = $this->getResource( 'view' ); $view->navigation = array(); $view->subnavigation = array(); $view->headTitle( 'Module One' ); $view->headLink()->appendStylesheet('/css/clear.css'); $view->headLink()->appendStylesheet('/css/main.css'); $view->headScript()->appendFile('/js/jquery.js'); $view->doctype( 'XHTML1_STRICT' ); //$view->navigation = $this->buildMenu(); } } Please go through it and let me know any knows how do configure module and layout in right way.. Thanks and regards, Prasanth P

    Read the article

  • Getting problem while capturing image through web cam in Java -OpenCV code.

    - by Chetan
    Hi.. I am developing Face detector using OpenCV library in java... I have written sample code for this,but it is giving Error while capturing image. can any one help please. Here is the code import java.awt.; import java.awt.event.; import java.awt.image.MemoryImageSource; import hypermedia.video.OpenCV; @SuppressWarnings("serial") public class FaceDetection extends Frame implements Runnable { ///Main method. public static void main(String[] args) { //System.out.println( "\nOpenCV face detection sample\n" ); new FaceDetection(); } // program execution frame rate (millisecond) final int FRAME_RATE = 1000/30; OpenCV cv = null; // OpenCV Object Thread t = null; // the sample thread // the input video stream image Image frame = null; // list of all face detected area Rectangle[] squares = new Rectangle[0]; //** Setup Frame and Object(s). FaceDetection() { super( "Face Detection" ); // OpenCV setup cv = new OpenCV(); //cv.capture(1, 1, 100); cv.capture( 320, 240 ); cv.cascade( OpenCV.CASCADE_FRONTALFACE_ALT ); // frame setup this.setBounds( 100, 100, cv.width, cv.height ); this.setBackground( Color.BLACK ); this.setVisible( true ); this.addKeyListener( new KeyAdapter() { public void keyReleased( KeyEvent e ) { if ( e.getKeyCode()==KeyEvent.VK_ESCAPE ) { // ESC : release OpenCV resources cv.dispose(); System.exit(0); } } } ); // start running program t = new Thread( this ); t.start(); } // Draw video frame and each detected faces area. public void paint( Graphics g ) { // draw image g.drawImage( frame, 0, 0, null ); // draw squares g.setColor( Color.RED ); for( Rectangle rect : squares ) g.drawRect( rect.x, rect.y, rect.width, rect.height ); } @SuppressWarnings("static-access") public void run() { while( t!=null && cv!=null ) { try { t.sleep( FRAME_RATE ); // grab image from video stream cv.read(); // create a new image from cv pixels data MemoryImageSource mis = new MemoryImageSource( cv.width, cv.height, cv.pixels(), 0, cv.width ); frame = createImage( mis ); // detect faces squares = cv.detect( 1.2f, 2, OpenCV.HAAR_DO_CANNY_PRUNING, 20, 20 ); // of course, repaint repaint(); } catch( InterruptedException e ) {;} } } } Error while starting capture : device 0

    Read the article

  • I need to get VMWare Server running inside of a VMWare ESXi virtual machine

    - by Josh Moore
    Yes, I know running a virtual machine inside of a virtual machine is a bad idea. Yes, I know it will be very slow. However, our production system required VMs in VMWare server and I do not want to setup a real server for each of our developers for testing. I would like to be able to setup all of the VMWare servers (that mimic our production environment) on one ESXi server. I have found as much info as I can about this topic and I have tried what was suggested here and here. I have not been able to get any of these suggestions to work, I still get the VM cannot run inside of a VM error. If there are any other suggestions that anybody else have that would be great thanks.

    Read the article

  • Socket(TCPIP) Unstable

    - by Lee Kwan Wee
    I have a setup of a SCPI server in a Win7 PC and have 2 other programs talking to it locally(127.0.0.1) over TCPIP socket 5025 and 5029. This worked well and stable in a fresh PC, but when we moved it into our production lines and the IT dept added their policies and stuff, it became unstable. The PC is connected to the production floor server but both of the programs are running locally in the PC. The connection tends to be disconnected when there is an idle period. And it takes 5-6times to refreshing the connection to get it back. I'm not a programmer myself, so I'm hoping to see if anyone here can help with some answers. Thank you very much!! Regards, KwanWee.

    Read the article

  • csync2 ERROR: Connection to remote host failed

    - by Emil Salama
    I was unable to find any articles to answer this question, so my best bet was to post this here: Scenario We have 2x application servers in production hosting a PHP website and I would like some folders to be syncronized between the 2, the same was setup for the development environment with no issues, I've followed all instructions from the URL "http://www.cloudedify.com/synchronising-files-in-cloud-with-csync2/", I still seem to have the same result, firewall has been disabled on both boxes for troubeshooting purposes: Config Files: cysnc2.cfg nossl * *; group production { host server1; host server2; key /etc/csync-production-group.key; include /etc/httpd/sites-available; include /xxxxxx/public_html/files include /xxxxxxx/magento/media/catalog/product include /xxxxxxx/magento/media/brands exclude *.log; exclude /xxxx/public_html/file/cache; exclude /xxxxx/public_html/magento/var/cache; exclude /xxxx/public_html/logs; exclude /xxxxx/public_html/magento/var/log; backup-directory /data/sync-conflicts/; backup-generations 2; auto younger; } /etc/xinetd.d/csync2 csync2.cfg service csync2 { disable = no flags = REUSE socket_type = stream wait = no user = root group = root server = /usr/sbin/csync2 server_args = -i -D /data/sync-db/ port = 30865 type = UNLISTED log_type = FILE /data/logs/csync2/csync2-xinetd.log log_on_failure += USERID } I've made sure that the daemon is listening on both server on port 30865 and the keys matched on both servers I've run a tcpdump on each server, output as follows: 12:20:31.366771 IP server1.49919 server2.csync2: Flags [S], seq 445156159, win 14600, options [mss 1460,sackOK,TS val 794864936 ecr 0,nop,wscale 7], length 0 12:20:31.366810 IP server2.csync2 server1.49919: Flags [S.], seq 450593575, ack 445156160, win 14480, options [mss 1460,sackOK,TS val 794798911 ecr 794864936,nop,wscale 7], length 0 12:20:31.367101 IP server1.49919 server2.csync2: Flags [.], ack 1, win 115, options [nop,nop,TS val 794864937 ecr 794798911], length 0 12:20:31.367138 IP server1.49919 server2.csync2: Flags [P.], seq 1:9, ack 1, win 115, options [nop,nop,TS val 794864937 ecr 794798911], length 8 12:20:31.367147 IP server2.csync2 server1.49919: Flags [.], ack 9, win 114, options [nop,nop,TS val 794798912 ecr 794864937], length 0 12:20:31.368625 IP server2.csync2 server1.49919: Flags [R.], seq 1, ack 9, win 114, options [nop,nop,TS val 794798913 ecr 794864937], length 0 Is there anything else i'm missing or should be doing?

    Read the article

  • Unable to set nginx to serve my staging website

    - by user100778
    I'm having some troubles setting up nginx to serve my staging website. What I did is change the server_name but for some reasons it just doesn't work. The url scheme is "domain.foo" is production, "staging.domain.foo" is staging, "foobar.domain.foo" is a web service, "foobar.staging.domain.foo" is the staging version of the same webserver, ".domain.foo" is routed to serve some s3 static HTML, ".staging.domain.foo" is routed to serve some s3 static HTML in another bucket. All production urls work and are correctly configured, all staging urls doesn't work. Here is my conf file. You will see some duplication, I will gladly accept any correction/optimization, I'm a coder and configuring servers is definitely not my thing (but I'm eager to learn and improve...). server { listen 80; ## listen for ipv4 server_name "domain.foo" "www.domain.foo" default_server; access_log /var/log/nginx/access.log; client_max_body_size 5M; location / { proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_redirect off; location ~* \.(jpg|jpeg|gif|png|ico|css|bmp|js|html)$ { access_log off; expires max; root /home/foo/Foo/current/public; break; } if ($host ~ 'www.domain.foo') { rewrite ^/(.*)$ http://domain/foo/$1 permanent; } proxy_pass http://production; break; } } server { listen 80; server_name "staging.domain.foo"; access_log /var/log/nginx/access.staging.log; error_log /var/log/nginx/error.staging.log; client_max_body_size 5M; location / { proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_redirect off; proxy_pass http://staging; break; } } server { listen 80; ## listen for ipv4 server_name "foobar.domain.foo"; access_log /var/log/nginx/access.log; location / { proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_redirect off; if ($host = 'foobar.domain.foo') { proxy_pass http://foobar; break; } } } server { listen 80; ## listen for ipv4 server_name foobar.staging.domain.foo; location / { proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_redirect off; proxy_pass http://foobar_staging; break; } } server { listen 80; server_name "~^(.+)\.domain\.foo$"; location / { proxy_intercept_errors on; error_page 404 = http://domain.foo/404; set $subdomain $1; rewrite /$ "/$subdomain/index.html" break; rewrite ^ /$subdomain$request_uri? break; proxy_pass http://bucket.domain.foo.s3.amazonaws.com; } } server { listen 80; server_name "~^(.+)\.staging\.domain\.foo$"; location / { proxy_intercept_errors on; set $subdomain $1; rewrite /$ "/$subdomain/index.html" break; rewrite ^ /$subdomain$request_uri? break; proxy_pass http://bucket.staging.domain.foo.s3.amazonaws.com; } } upstream production { server 111.255.111.110:8000; server 111.255.111.110:8001; server 111.255.111.110:8002; server 111.255.111.110:8003; } upstream staging { server 222.255.222.222:8000; server 222.255.222.222:8001; } upstream foobar { server 111.255.222.165:9000; server 111.255.222.165:9001; server 111.255.222.165:9002; } upstream foobar_staging { server 222.255.222.222:9000; } What happens now when I point my browser to staging.domain.foo is that it hangs. Can't find anything in the logs, but for example the access.staging.log and errors.staging.log are created. Anybody has an idea? :)

    Read the article

  • iphone - manipulating movies

    - by Mike
    Is there a way to manipulate movies in iphone in a way I can have, for example, the exact timecode in realtime of a movie being played? or the timecode of a movie being scrubbed? And, btw, there's a way to scrub a video like the video edit mode of iPhone 3GS? Can you guys pinpoint me a way to follow, if any? thanks for any help.

    Read the article

  • UIModalPresentationFormSheet and MPMoviePlayer on iPhone/iPad OS 3.2?

    - by user325699
    I have a UIModalPresentationFormSheet which has a movie player inside of it. When the user hits the button to play it in full screen, my UIModalPresentationFormSheet is still there ontop of the video while it's playing in full screen, behind the window and behind the shadow. What do I need to do to get rid of the dim so the video is playing in fullscreen with being able to select buttons and not having an annoying dim ontop of it?

    Read the article

  • IE Kerberos failure on some machines with CNAME web server (with SPN for host's A record)

    - by Eric Thames
    It's fairly well known that IE doesn't like to do Kerberos against hosts that are registered in DNS as CNAMEs. What happens is that IE turns around and uses the underlying A record for the host for looking up the Service Principal Name (SPN). On a test network we are able to get Kerberos working by having the SPN registered for the A record of the host, so that Kerberos authentication happens successfully when accessing the web server via it's CNAME in the browser. Kerberos authentication works properly when directly accessing the web server with the A record host in the URL, but for various reasons that are beyond my control, it is desired to use the CNAME. On the production network, this same configuration fails though and I can't figure out why. Any thoughts? This is a java web application using the SPNEGO library - not IIS. Kerberos authentication is working properly in both the test and production networks (and has been confirmed to not fail back to NTLM), but the CNAME access only works in test.

    Read the article

  • Configure Nagios To Alert Depending On Host Group That Service Alert Originates From

    - by StrangeWill
    So my setup: Services are shared between all hosts (CPU/RAM/Disk/Services). Hosts are split into two main groups: "Production" and "Development". We have two contact groups: "Production" and "Development". Lets say my development SQL server runs low on RAM, I want it to only alert those in "Development" contact group (this service is of course assigned to a host in the "Development" host group, using the shared RAM monitoring service). I'm pretty much stumped on this... I can't configure it at the service level (they're shared there), and I can't seem to get escalations to do it for me either... Do I need to use service groups along with escalations and bite the bullet on building that list? Or am I missing something stupidly simple? I'm using Centreon for configuration if that helps.

    Read the article

  • WP Oembed not passing through the “autoplay=1” variable

    - by criticerz
    Hi guys, I'm having a problem here.. I am passing this through a custom field: http://www.youtube.com/watch?v=E6P1Q-UycHA&autoplay=1 (notice the "autoplay=1") But when I load the video on my theme using wp_oembed_get... it displays the video fine, but it does not listen to the "autoplay=1" variable I am passing through. I need the videos to play on the load of the page. Any ideas? Thanks, Alain Fontaine

    Read the article

  • SQL Server 2008 R2 SQL Server has encountered x occurrence(s) of I/O requests taking longer than 15 seconds to complete on file

    - by Natalia
    When I alter or create a stored procedure directly on production or QA database, after a few seconds I start experience timeouts and application becomes unavailable. Log files shows this error: SQL Server has encountered 3 occurrence(s) of I/O requests taking longer than 15 seconds to complete on file [C:\Program Files\Microsoft SQL Server\MSSQL10_50.MSSQLSERVER\MSSQL\DATA\QA_Database.ldf] in database [QA_Database] (9). The OS file handle is 0x0000000000000568. The offset of the latest long I/O is: 0x0000002821a200 We have SQL Server 2008 R2 installed, including latest Service Pack. Production and staging environments are completely separated. I tried to reproduce it on QA, but to no avail. I have no clue what it could be. Appreciate your help.

    Read the article

  • Windows Resource Monitoring Programs

    - by Sal
    I work at a small tech start up managing websites with our own in house server side code. (In production, we use Windows Server 2008 boxes, running Java 6. In our dev boxes, we use Windows 7 running Java 7.) Recently, we had an issue where some of our boxes in production failed, and we didn't have means of trouble shooting, since we keep little to no monitoring logs about a given box's CPU/memory/RAM usage, etc. So, I'm wondering if there is some commercial/freeware that's the standard for performance monitoring/logging. Essentially, I'm just looking for an analytics system that is similar to the Windows Task Manager or the Resource Monitor, that serializes all of its data periodically. Ideally, I'd like to find a program that's also extensible, in case I'd like to add addition monitors in the future.

    Read the article

  • Issue with VMWare vSphere and NFS: re occurring apd state

    - by Bastian N.
    I am experiencing issues with VMWare vSphere 5.1 and NFS storage on 2 different setups, which result in an "All Path Down" state for the NFS shares. This first happened once or twice a day, but lately it occurs much more frequent, as specially when Acronis Backup jobs are running. Setup 1 (Production): 2 ESXi 5.1 hosts (Essentials Plus) + OpenFiler with NFS as storage Setup 2 (Lab): 1 ESXi 5.1 host + Ubuntu 12.04 LTS with NFS as storage Here is an example from the vmkernel.log: 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 248: APD Timer started for ident [987c2dd0-02658e1e] 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 395: Device or filesystem with identifier [987c2dd0-02658e1e] has entered the All Paths Down state. 2013-05-28T08:07:33.479Z cpu0:2054)StorageApdHandler: 846: APD Start for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4cf28 3 2013-05-28T08:07:37.485Z cpu0:2052)NFSLock: 610: Stop accessing fd 0x410007e4d0e8 3 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 277: APD Timer killed for ident [987c2dd0-02658e1e] 2013-05-28T08:07:41.280Z cpu1:2049)StorageApdHandler: 402: Device or filesystem with identifier [987c2dd0-02658e1e] has exited the All Paths Down state. 2013-05-28T08:07:41.281Z cpu1:2049)StorageApdHandler: 902: APD Exit for ident [987c2dd0-02658e1e]! 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4d0e8 again 2013-05-28T08:07:52.300Z cpu1:3679)NFSLock: 570: Start accessing fd 0x410007e4cf28 again As long as the issue occurred once or twice a day it really wasn't a problem, but now this issue has impact on the VMs. The VMs get slow or even hang, resulting in a reset through vCenter in the production environment. I searched the web extensively and asked in forums, but till now nobody was able to help me. Based on blog posts and VMWare KB articles I tried the following NFS settings: Net.TcpipHeapSize = 32 Net.TcpipHeapMax = 128 NFS.HartbeatFrequency = 12 NFS.HartbeatMaxFailures = 10 NFS.HartbeatTimeout = 5 NFS.MaxQueueDepth = 64 Instead of NFS.MaxQueueDepth = 64 I already tried other settings like NFS.MaxQueueDepth = 32 or even NFS.MaxQueueDepth = 1. Unfortunately without any luck. It would be great if someone could help me on this issue. It is really annoying. Thanks in advance for all the help. [UPDATE] As I explained in the comment below, here is the network setup: On the production setup the NFS traffic is bound to a separate VLAN with ID 20. I am using a HP 1810 24 Port Switch. The OpenFiler system is connected to the VLAN with 4 Intel GbE NICs with dynamic LACP. The ESXis both have 4 Intel GbE NICs using 2 static LACP trunks containing 2 NICs each. One pair is connected to the regular LAN and the other one to the VLAN 20. And here is a screenshot of the vSwitch: Switch configuration: Port configuration: On the lab setup its a single Intel NIC on each side without VLAN, but with different IP subnet.

    Read the article

< Previous Page | 213 214 215 216 217 218 219 220 221 222 223 224  | Next Page >