Search Results

Search found 16628 results on 666 pages for 'setup kit'.

Page 229/666 | < Previous Page | 225 226 227 228 229 230 231 232 233 234 235 236  | Next Page >

  • How can order of IP addresses issued be controlled?

    - by warren
    Every home router I've setup/used issues addresses from low to high. However, dhcpd from the Internet Systems Consortium seems to issue addresses in reverse order - ie, high to low. Is there a way to change this so that addresses are issued starting at the bottom of the range, and progress higher?

    Read the article

  • APPCMD syntax issue

    - by Adam
    I am trying to setup recycling logging events, using the following: appcmd set config /section:applicationPools /[name=' AppPoolName '].recycling.logEventOnRecycle:time But I am getting this error: Failed to process input: The parameter ''].recycling.logEventOnRecycle:time' mus t begin with a / or - (HRESULT=80070057). I used this technet article but I cannot figure out where I went wrong. Any ideas?

    Read the article

  • New monitor connected to HDMI adaptor doesn't show output after booting

    - by Paul
    Hello out there in the multiple monitors’ world. I am a very old newbie in your world and need help. I just purchased a new Asus VH236H monitor and hooked it up the HDMI port of an ATI Radeon HD4300 / 4500 Series display adaptor. I left the old Princeton LCD19 (TMDS) hooked up to the DVI port of the same display adaptor. Both monitors displayed the boot sequence, after I fired good old Sarastro2 (Asus P5Q Pro Turbo – Dual Core E5300 – 2.60 GHz) up. The Asus lacked one half of a second behind the Princeton until the Windows 7 Ultimate SP 1 boot up was complete. Then the Asus displayed “HDMI NO SIGNAL” and went into hibernation. The Princeton stayed lit up as before. Both monitors are displayed on the “Screen Resolution Setup Display” and I plaid around with them for a while. The only thing I accomplished was to shove the desktop icons from the Princeton to the still hibernating Asus. The “Multiple displays:” is set to “Extend these displays”, the Orientation is “Landscape” and the Resolutions are set on both to the “recommended” one. Both monitors show that they work properly in the advanced Properties display. What am I doing wrong, what am I missing? Never mind the opinions about the different resolutions of the two monitors. I always can unhook the Princeton and give it to a Goodwill Store if I do not like the setup. I just would like to make it work. Any constructive help is very much appreciated, Thank you. Thank you Anees Bakrain Only the ATI Radeon HD 4300/4500 Series adapter is displayed in the Device Manager, for that reason I have to assume that the onboard display adaptor is not active. All 40 drivers of Sarastro2 are up to date and the HDMI cable can not be the problem because both monitors displayed the boot sequence up to the moment when Windows 7 was loaded completely. This was the moment, when the Asus monitor lost its signal. Both connectors, HDMI and DVI are connected and removing the DVI connector would not solve my problem of running both monitors simultaneously. However, your suggestions shifted my seventy one year old brain into the next gear. The only question remaining is; “Why the signals to the Asus monitor stop after the sequence is complete”. The ATI Radeon HD 4300/4500 Series adapter seems to be capable of sending simultaneous HDMI and DVI signals, what is done during the boot sequence. Why do the signals change after the boot sequence is complete is the key question or der springende Punkt? Is this a correct assumption slhck?

    Read the article

  • grouping two sites under domain and sub domain

    - by Dave
    I have 2 websites a main website hosted at fasthosts and an e-commerce website hosted at Vidahost. I want to combine both websites under the same domain set. Main site would be www.mydomain.com Store site would be shop.mydomain.com I want to keep the directory path showing on the shop subdomain so what was previously www.mystore.com/product/hat would become shop.mydomain.com/product/hat How can I accomplish this, have already created the subdomain on fasthosts and setup web forwarding to the store but the directory paths do not show.

    Read the article

  • Are memory leaks really something to worry about?

    - by chuck final
    I came across this post today, arguably debatable/wrong somewhat, but worth a shot looking over: http://andyharglesiscodebase.wordpress.com/2013/11/01/why-programmers-shouldnt-worry-about-memory-leaks/ The poster claims that modern OSes automatically have garbage collection implemented in the kernel memory, and that any unfreed user heap memory is managed during "post partum cleanup". It seems like rubbish, but I can't be 100% sure since I am not that knowledgeable on the kernel's memory management setup, etc.

    Read the article

  • I have a new seagate 3tb hard drive and when i installed it it says 349gb free

    - by Joseph Sexton
    my new seagate sata drive keeps showing as a 249gb drive but in the setup part when i press del at the boot up it states there a 3000gb drive and i have searched for a solution but havent found one yet. I havent tried in a different pc yet and I have an asus gaming board with 2 video cards sli'ed and i have windows 7 ultimate 64 bit with 8gb ram and a hp 23" widescreen monitor and the sniper gaming case and a salitek lighted up gaming keyboard and a razor death adder gaming mouse and a corsair 850 watt power supply. Any help would be great and appriciated

    Read the article

  • Multi-site email relay based on email address (in AD?)

    - by MarkRobinson
    We have a multi site setup currently based around Exchange 2003, but we are getting a lot of traffic over the vpn as only one server has an internet facing IP. Is there such a product that could sit on a hosted rack somewhere that would look at an incoming email and from information in AD determine which mail server to relay the message to?

    Read the article

  • Setting up Mail Server (mx.domain.com) using MailEnable in IIS 7.5

    - by Zee Tee
    I have setup MailEnable Standard on my server and have created the PostOffice (domain/mailbox) for the domain which I intend to be using. I have the DNS settings in GoDaddy like this: A (Host) Host: '@' Points To: IP MX Record Priority: 0 Host: 'mx' Points To: @ Is there anything in IIS that needs to be done to make mx.domain.com work as a mail server that can be used in other domain names? Additionally, On the firewall, I have the Outbound port 25 open, not sure, should I be opening port 25 on Inbound as well?

    Read the article

  • Ubuntu Desktop system restore ?

    - by neolix
    Hello Geeks, We are using all the desktop ubuntu 8.04 to 10.04, we are looking same thing like system resorting to back date like windows feature. Around 500 desktop and 79 server we want to setup. Thanks

    Read the article

  • HTML notes in freemind

    - by asdf
    Hi, I wonder if the following things can be done with the HTML notes pane of freemind: Is it possible on the layout view to decrease the separation between lines? The panel is horizontal, is it possible to setup a vertical view? (I have a big, horizontal-like monitor) By the way, when I move the mouse pointer over a node, i can see the HTLM note associated with it, but its view (as a yellow square) only lasts for some seconds. Can it be made permament? Thanks a lot

    Read the article

  • Image backup with two Macs

    - by Konzepz
    Hi, My setup is as follows: iMac + Ext. HD in the living room A MacBook I want to create a regular weekly backup flow, that will create an image file for the MacBook (the entire disk image), and save it to the ext. HD on the iMac, meaning -- connect via local network and save the file. What's the best practice/application for this? Thank you.

    Read the article

  • Complete stack traces from Hyperic

    - by Mike Kushner
    I've setup Hyperic to run on our CI-machine, and every once in a while it reacts to some random stack trace and sends of an alert. So far so good, we've caught a lot of intermittent bugs that way. My only issue is that the alert only contains the first error line and not the entire stack trace, which requires me to access the machine and look at the logs manually. Is there any way to modify the alert message to contain more information, alternatively to include the log file in the alert mail?

    Read the article

  • Can I enable discards on a LUKS-encrypted ssd drive in RHEL6 (and do I need to)?

    - by Dan Nestor
    I have a RHEL 6.4 workstation, running on a LUKS-encrypted LV residing on a SSD. I found RedHat documentation stating that dm_crypt does not currently support TRIM passthrough, however I also found other sources that state the opposite (albeit for other distributions) and even that discards are not needed for recent SSD drives which use some sort of automatic garbage collection. So: 1) Can I enable TRIM/discards with my setup? 2) Do I need to, for optimal disk performance? Thanks for your thoughts.

    Read the article

  • Setting a Preferred Network Adapter for browsing

    - by ala
    My PC at work is connected to 2 networks; LAN: local corporate network for remote desktop access and very slow internet connection WAN: wireless faster internet browsing Is there a way to setup the default/preferred network adapter for the internet browsing?

    Read the article

  • A compression program that handles files with unusual extensions

    - by ripper234
    WAR files are simply ZIP files with a renamed extension. I'd like to configure a compression program to handle these (on double-clicking the file), but jZip doesn't recognize them unless I rename them to .ZIP. I have setup Windows file associations, but jZip just wants to 'add them to archive' instead of opening them. Which compression program would you recommend?

    Read the article

  • How can I make monodevelop render text in KDE?

    - by Spikolynn
    Monodevelop from git in KDE 4.10.2 does not render text in code edit tabs I tried with xfce and text is rendered ok there. I tried disabling composition with alt shift f12 and restarting x server but it was no better. I also tried disabling font softening in monodevelop options and disabling plugins. I also tried temporarily deleting my KDE profile. This is dual screen setup on Nvidia with nouveau. OS is slackware64-current.

    Read the article

  • Cannot install grub to RAID1 (md0)

    - by Andrew Answer
    I have a RAID1 array on my Ubuntu 12.04 LTS and my /sda HDD has been replaced several days ago. I use this commands to replace: # go to superuser sudo bash # see RAID state mdadm -Q -D /dev/md0 # State should be "clean, degraded" # remove broken disk from RAID mdadm /dev/md0 --fail /dev/sda1 mdadm /dev/md0 --remove /dev/sda1 # see partitions fdisk -l # shutdown computer shutdown now # physically replace old disk by new # start system again # see partitions fdisk -l # copy partitions from sdb to sda sfdisk -d /dev/sdb | sfdisk /dev/sda # recreate id for sda sfdisk --change-id /dev/sda 1 fd # add sda1 to RAID mdadm /dev/md0 --add /dev/sda1 # see RAID state mdadm -Q -D /dev/md0 # State should be "clean, degraded, recovering" # to see status you can use cat /proc/mdstat This is the my mdadm output after sync: /dev/md0: Version : 0.90 Creation Time : Wed Feb 17 16:18:25 2010 Raid Level : raid1 Array Size : 470455360 (448.66 GiB 481.75 GB) Used Dev Size : 470455360 (448.66 GiB 481.75 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Thu Nov 1 15:19:31 2012 State : clean Active Devices : 2 Working Devices : 2 Failed Devices : 0 Spare Devices : 0 UUID : 92e6ff4e:ed3ab4bf:fee5eb6c:d9b9cb11 Events : 0.11049560 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 17 1 active sync /dev/sdb1 After bebuilding completion "fdisk -l" says what I have not valid partition table /dev/md0. This is my fdisk -l output: Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00057d19 Device Boot Start End Blocks Id System /dev/sda1 * 63 940910984 470455461 fd Linux raid autodetect /dev/sda2 940910985 976768064 17928540 5 Extended /dev/sda5 940911048 976768064 17928508+ 82 Linux swap / Solaris Disk /dev/sdb: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000667ca Device Boot Start End Blocks Id System /dev/sdb1 * 63 940910984 470455461 fd Linux raid autodetect /dev/sdb2 940910985 976768064 17928540 5 Extended /dev/sdb5 940911048 976768064 17928508+ 82 Linux swap / Solaris Disk /dev/md0: 481.7 GB, 481746288640 bytes 2 heads, 4 sectors/track, 117613840 cylinders, total 940910720 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table This is my grub install output: root@answe:~# grub-install /dev/sda /usr/sbin/grub-setup: warn: Attempting to install GRUB to a disk with multiple partition labels or both partition label and filesystem. This is not supported yet.. /usr/sbin/grub-setup: error: embedding is not possible, but this is required for cross-disk install. root@answe:~# grub-install /dev/sdb Installation finished. No error reported. So 1) "update-grub" find only /sda and /sdb Linux, not /md0 2) "dpkg-reconfigure grub-pc" says "GRUB failed to install the following devices /dev/md0" I cannot load my system except from /sdb1 and /sda1, but in DEGRADED mode... Anybody can resolve this issue? I have big headache with this.

    Read the article

  • Custom hostname instead ISP's

    - by JohnZ
    Hi! I have setup a Centos 5.5 server and a domain name (say mydomain.com) pointing to it (using bind9) with custom nameservers (like ns1.mydomain.com and ns2.mydomain.com). Everything works fine but there is something more I would like to have and don't know if it is possible. Is it possible to have the returned host to be mydomain.com (PHP gethostbyaddr()), not host-static-x-y-a-b.myisp-provider.com? And how do I implement it if it's possible?

    Read the article

  • Any tool to check which ports/protocols firewalls prevent?

    - by Jus12
    Suppose I have a setup as: host_1 --- Firewall_1 --- Internet --- Firewall_2 --- host_2 I need to check which ports are open on host_2 from host_1 (which may be blocked by either firewalls) If there a tool that comes in two parts (one running on host_1 and other on host_2) that does this for me? It should be something like: 1 Listen to all ports on host_2 2 Try to connect to every port on host_2 from host_1 3 Give a report what ports are allowed.

    Read the article

  • Operative systems on SD cards

    - by HisDudeness
    I was getting some wild ideas the last days, like putting some operative systems into SD cards rather than on my hard drive. I'll go further into details now and explain what lead me to consider this probably abominable decision. I am on a laptop (that means I have a native SD-card reader) which is currently running a cross-distro setup, with a bunch of Linux systems (placed in dedicated ext4 logical partitions into a huge extended one) regulated by an unique GRUB. Since today, my laptop haven't even seen any Windows system with binoculars. I was thinking about placing all the os part of my setup into a Secure Digital to save all my 500 Gb Hard Drive for documents, music, videos and so on, and being able to just remove the SD and boot my system into another computer too, as well as having the possibility of booting other systems into mine by just plugging in another SD, without having to keep it constantly placed in my PC. Also, in the remote case in the near future I just wanted to boot Windows 8 in it, I read it causes major boot incompatibility issues with other systems by needing a digital signature in order for them to start. By having it in a removable drive, I could just get rid of it when I'm needing him and switch its card with Linux one, and so not having any obstacles to their boot. Now, my questions are: I know unlikely traditional rotating disk drives, integrated circuits ones have a limited lifespan in terms of cluster rewriting. Is it an obstacle to that kind of usage? I mean, some Ultrabooks are using SSD now, is it the same issue, or there are some differences between Solid State Drives and Secure Digitals in that sense? Maybe having them to store system files which are in fixed positions (making the even-usage of cluster technology useless) constantly being re-read and updated and similar things just gets them soon unserviceable, do it? Second question: are all motherboards and BIOSes able to boot from SDs just like they are from USB pen drives (I mean, provided card reader is USB-connected, isn't it)? Or can't bootloaders like GRUB be installed on SDs working? If they can't, is it a solution installing GRUB to MBR and making boot option pointing to SD? Will it work? Are there any other problems to installing OSs on a Secure Digital?

    Read the article

< Previous Page | 225 226 227 228 229 230 231 232 233 234 235 236  | Next Page >