Search Results

Search found 7107 results on 285 pages for 'rotate monitor'.

Page 241/285 | < Previous Page | 237 238 239 240 241 242 243 244 245 246 247 248  | Next Page >

  • "Unable to open MRTG log file" error with nagios and mrtg

    - by Simone Magnaschi
    We have a strange issue with our setup of icinga / nagios and mrtg. Icinga is working great and has no problem, it can monitor basically everything without issues. We setup mrtg to gather bandwith data from our routers and switches. MRTG is working fine: it stores the log data in the /var/www/mrtg/ directory and displays the graph data via web. We assume so MRTG is doing great. We tried to setup bandwidth checks in nagios: define service{ use generic-service ; Inherit values from a template host_name zywall-agora service_description ZYWALL AGORA TRAFFICO check_command check_local_mrtgtraf!/var/www/mrtg/x.x.x.x_2.log!AVG!1000000,2000000!5000000,5000000!1000 check_interval 1 ; Check the service every 1 minute under normal conditions retry_interval 1 ; Re-check every minute until its final/hard state is determined } Where /var/www/mrtg/x.x.x.x_2.log is the correct log path file. We keep on getting Unable to open MRTG log file error in the test result in icinga web interface. We tried everything: give ownership to user nagios or icinga to the log file give chmod 777 to the file try to copy the file in another directory and give it full permission Same error. The strange thing is that if we use the command that nagios generate in a bash session the command works like a charm: /usr/lib64/nagios/plugins/check_mrtgtraf -F /var/www/mrtg/x.x.x.x_2.log -a AVG -w 10,20 -c 5000000,5000000 -e 10 Result: Traffic WARNING - Avg. In = 17.9 KB/s, Avg. Out = 5.0 KB/s|in=17.877930KB/s;10.000000;5000000.000000;0.000000 out=5.000000KB/s;20.000000;5000000.000000;0.000000 We ran that command line as root, as user nagios and as user icinga and all three worked ok. We thought that the command that nagios perform maybe has something wrong in it, so we debugged nagios but we found out that the generated command from nagios is the same as above. Searching on google for these kind of problem returns only issues of systems where mrtg is not installed or issues with the wrong path to the log file, but these seems not to be our case. We are stuck, can somebody help?

    Read the article

  • Implement QoS/Bandwidth Management or Upgrade Bandwidth?

    - by Michael
    A question that I'm faced with currently. Here's my setup: Cisco ASA 5510 15Mbps Internet Connection @ $1350/month The bandwidth was originally meant for 35-45 people but we've grown quite quickly to roughly 60-65 people. Needless to say, when I check bandwidth logs it's almost always spiked at 15Mbps. I did use Wireshark to do some poking around to see what was hogging up our bandwidth but with everything running through CDNs and Cloud Services it proved difficult to get a good grasp of where our bandwidth was going. So the question is do I ONLY implement bandwidth management through ASA OR upgrade the Internet to 50Mbps ($1600/month) and then implement bandwidth management through ASA? Any suggestions on how to segment the 15Mbps connection if we decided ONLY to go with the bandwidth management solution? Thanks. UPDATE 1 Installed PRTG and used packet content to monitor the traffic. As I suspected still pretty vague. My Top Connections include the following: a204-2-160-16.deploy.akamaitechnologies.com ec2-50-16-212-159.compute-1.amazonaws.com a204-2-160-48.deploy.akamaitechnologies.com a72-247-247-133.deploy.akamaitechnologies.com mediaserver-sv5-t1-1.pandora.com Other than the Pandora destination, the rest doesn't tell me much on how to properly control the bandwidth. Any thoughts or suggestions? Thanks. M

    Read the article

  • Benchmarking a file server

    - by Joel Coel
    I'm working on building a new file server... a simple Windows Server box with a few terabytes of disk space to share on the LAN. Pain for current hard drive prices aside :( -- I would like to get some benchmarks for this device under load compared to our old server. The old server was installed in 2005 and had 5 136GB 10K disks in RAID 5. The new server has 8 1TB disks in two RAID 10 volumes (plus a hot spare for each volume), but they're only 7.2K rpm, and of course with a much larger cache size. I'd like to get an idea of the performance expectations of the new server relative to the old. Where do I get started? I'd like to know both raw potential under different kinds of load for each server, as well an idea of what our real-world load looks like and how it will translate. Will disk load even matter, or will performance be more driven by the network connection? I could probably fumble through some disk i/o and wait counters in performance monitor, but I don't really know what to look for, which counters to watch, or for how long and when. FWIW, I'm expecting a nice improvement because of the benefits of having two different volumes and the better RAID 10 performance vs RAID 5, in spite of using slower disks... but I'd like to get an idea of how much.

    Read the article

  • Unexplained CPU and Disk activity spikes in SQL Server 2005

    - by Philip Goh
    Before I pose my question, please allow me to describe the situation. I have a database server, with a number of tables. Two of the biggest tables contain over 800k rows each. The majority of rows are less than 10k in size, though roughly 1 in 100 rows will be 1 MB but <4 MB. So out of the 1.6 million rows, about 16000 of them will be these large rows. The reason they are this big is because we're storing zip files binary blobs in the database, but I'm digressing. We have a service that runs constantly in the background, trimming 10 rows from each of these 2 tables. In the performance monitor graph above, these are the little bumps (red for CPU, green for disk queue). Once ever minute we get a large spike of CPU activity together with a jump in disk activity, indicated by the red arrow in the screenshot. I've run the SQL Server profiler, and there is nothing that jumps out as a candidate that would explain this spike. My suspicion is that this spike occurs when one of the large rows gets deleted. I've fed the results of the profiler into the tuning wizard, and I get no optimisation recommendations (i.e. I assume this means my database is indexed correctly for my current workload). I'm not overly worried as the server is coping fine in all circumstances, even under peak load. However, I would like to know if there is anything else I can do to find out what is causing this spike? Update: After investigating this some more, the CPU and disk usage spike was down to SQL server's automatic checkpoint. The database uses the simple recovery model, and this truncates the log file at each checkpoint. We can see this demonstrated in the following graph. As described on MSDN, the checkpoints will occur when the transaction log becomes 70% full and we are using the simple recovery model. This has been enlightening and I've definitely learned something!

    Read the article

  • What's the right way to start a node.js service?

    - by elliot42
    I'm running a node.js service (statsd) on CentOS 6. What's the proper way to daemonize and start such a service? Potential Daemonizers--are daemonizers supposed to be language-specific or general?: forever (node-specific) daemonize nohup (presumably wrong) start-stop-daemon(debian-only? is this for daemonizing or starting/stopping? what is the Centos equivalent?) Should the app itself really know how to daemonize itself and then have a -d flag? (e.g. via node-daemonize2 or forever-monitor?) Service starters--should these be from the system/distro, or should they be from monitoring tools such as monit?: service? is really /etc/init.d on CentOS? service? is really Upstart on Ubuntu? monit? daemontools? runit? I'm unfortunately new to this--where can I read up on what is the most standard, classic, reliable way of doing this?

    Read the article

  • VLAN support on Juniper EX - 2200 switches

    - by liv2hak
    I have 6 Juniper switches (EX - 2200) connected to each other as shown in the network topology below. I have two PC's that I am using PC1 - (used for configuring the 6 switches via minicom) PC2 - to monitor the traffic between the switches via the Ports that are marked with arrows in the diagram. STEP 1: I create a new vlan On Switch 3 (SW3) that includes Port 12 and Port 22. I also assign l3-interface to the vlan (vlan_2) with ip address - 192.168.1.7. Now I plug-in Port 0 of Switch 3 on PC2. Now I try pinging 192.168.1.7 from PC2 (192.168.1.10) I want to know what will happen? My postulation is that I will not be able to ping SW3 from PC2.This is because SW3 (Port 12 and Port 22) is a part of a vlan_2 and vlan_2 logically breaks up broadcast domains and so 192.168.1.7 will not be reachable from 192.168.1.10. Now I have an l3-interface on SW1 with IP 192.168.1.1 using default vlan( vlan-id 0). Similarly I have enabled IP on SW2 - 192.168.1.2 SW3 - 192.168.1.3 SW4 - 192.168.1.4 SW5 - 192.168.1.5 SW6 - 192.168.1.6 all using default vlan. Now I plug in Port 12 of SW3 (blue cable) into the PC2. I try to ping 192.168.1.1 from PC2. What will happen at this stage.? My postulation is that I will be able to ping switch 1.Is this correct? Also another question is that can a single port on a Switch be added multiple VLANS? I am a beginner at network configuration? Any help would be highly appreciated. (Please ignore the CISCO symbol on the switches in the diagram.All swithes are Junper EX 22-00.)

    Read the article

  • Hardware reserved memory issue

    - by Robert Koritnik
    I've seen lots of folks having problem with hardware reserved memory issue in Windows 7/Server 2008 R2. I have it myself but not as huge as others have. Problem description When you install Windows 7 (or its bigger brother Windows Server 2008 R2) your memory may not be fully utilised. If you look at Task Manager > Performance Tab > Resource Monitor > Memory Tab And scroll to the bottom of the list you will see a graphical representation of your memory. Some of it may be hardware reserved. Previous Windows versions didn't have this problem. System was able to utilise all memory available. Question Is there any solution to lower/remove hardware reserved memory? Sidenote I tried installing 32 and 64 bit versions but to no avail. I also tried both Windows: 7 and Server 2008 R2. But always get the same amount reserved by HW. On previous Windows versions I had more memory available because I'm simultaneously running 2 VMs on host (so three machines all together). And my memory peaks much higher now as it did on older versions.

    Read the article

  • How do I locate the app generating this network traffic?

    - by Christopher Bartels
    I don't know what this process is doing on my computer. I run Windows 7 Professional w/ all its updates running current non-free antivirus. I only see it in Resource Monitor, where you can see the Network Service process connected to bitum.nnov.ru. When my PC's network traffic generating apps are idle, this process is using the most of all the idle processes using the network. Screenshot hosted here: http://sss.proinbox.com/bitum-nnov-ru.jpg Does anyone recognize this? The page source mentions a control port & a stream port: Page Source for http://bitum.nnov.ru : <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"> <html> <head> <title>DVR WebViewer</title> <meta http-equiv="Content-Type" content="text/html; charset=euc-kr"> </head> <body topmargin="0" leftmargin="0"> <OBJECT classid="clsid:EE479A40-C128-40DD-93DA-000556AF9607" codebase="CtrWeb.cab#version=1,0,2,2" width=875 height=585 align=center hspace=0 vspace=0 > <param name="CmdPort" value="5920"> <param name="StreamPort" value="5921"> </body> </html> When I google this page's title, I see a number of other domains that host the same page. Whois: domain: NNOV.RU nserver: ns.kis.ru. nserver: ns.nnov.ru. 78.25.80.210 nserver: ns1.kis.ru. nserver: ns2.kis.ru. state: REGISTERED, DELEGATED, VERIFIED org: "Agentstvo Delovoj Svjazi", Ltd registrar: RU-CENTER-REG-RIPN admin-contact: https://www.nic.ru/whois created: 1996.10.23 paid-till: 2012.11.01 free-date: 2012.12.02 source: TCI Last updated on 2012.06.16 04:20:46 MSK

    Read the article

  • Intel Core i7 QuadCore on HP Pavilion dv7 Overheating Issues

    - by kellax
    I bought a brand new HP notebook: HP Pavilion dv7-6b21em BeatsAudio edition. The notebook is about 2 months old and has pretty nasty overheating problem. I mainly use it for development however i do play some games. The disturbing thing is that the computer is loud on pretty simple tasks. Here are the specs: CPU: Intel Core i7-2670QM QuadCore ( 8 threads ) @ 2.20 GHz RAM: ( 8GB ) 2x 4GB @ 1066 HDD: 1TB 7200 GPU: ATI Radeon HD 6770M 1GB Dedicated DDR OS: Windows 7 64bit Enterprise I have an external monitor runing on VGA port an 22' Samsung SyncMaster S24B300 CPU Heat Statistics Platform: rPGA 988B (Socket G2) Frequency: cca. 3000 Mhz VID: 1.1809 - 1.2059 v Revision: D2 CPUID: 0x206A7 TDP: 45.0 Wats, Lithographu: 32 nm Heat: Tj. Max: 100*C, Power 4.5 - 5.9 Wats Core #0: 63*C Load on all is about 0 to 2% Core #1: 65*C Core #2: 66*C Core #3: 67*C I opened the notebook the fan is working fine there is no dust but still right now the fan is pretty loud even tho all i have open is FireFox. When i run a game the heat jumps to whopping 90-97*C. It has not shut down due to overheating yet but the loud fan is pretty annoying considering I'm not really doing anything stressfull. Is there anything i can do to fix this is it maybe a BIOS issue ? I have all drivers updated tho to the latest. I have very few background processes running consuming bare 2GB of RAM and about 2% of CPU. I had it serviced they said there is nothing wrong with it. But i feel that a Notebook that costs 1.2k Euros cant be like this.

    Read the article

  • Dell Management Packs in System Center Operations Manager 2007 R2?

    - by bwerks
    Hey all, I recently set up SCOM in a small business network environment. The root management server is a Dell Poweredge 2950, and I'd like to use SCOM to monitor it using Dell's management packs. I've imported the management packs into the SCOM deployment and followed Dell's installation instructions, but it doesn't seem to be fully working yet. Currently, the Diagram views in the Dell tree (Monitoring tab) seem to show me the server's place in the network topology, so it seems that at least part of it is working. However, none of the reports under "Performance and Power Monitoring Views" provide any information. When clicking on one of them (Power Consumption (Watts), for instance), the display area is blank and there is a tooltip visible that reads "No performance counter is selected. To select a counter, place a check mark in the Show column in legend below." However, in the legend, there's nothing there for me to check. I've installed OpenManage 6.2 on the server as per the Dell documentation, but I don't know what else I could have done that I missed. Does this sound like a familiar problem to anyone?

    Read the article

  • nginx with stub_status.. need help with nginx.conf

    - by Amar
    Hello I am trying to setup nginx with stub status so I can monitor nginx requests etc.. with serverdensity.com. I needed to put something like this in nginx.conf server { listen 82.113.147.xxx; location /nginx_status { stub_status on; access_log off; allow 82.113.147.xxx; deny all; } } And with this monitoring acctualy works. However It seems I lost "include" part in my nginx.conf and now none of vhosts in sites-enabled work. Here is a bit more of my nginx.conf http { include /etc/nginx/mime.types; default_type application/octet-stream; server_tokens off; access_log /var/log/nginx/access.log; sendfile on; #tcp_nopush on; #keepalive_timeout 0; keepalive_timeout 65; tcp_nodelay on; gzip on; gzip_comp_level 2; gzip_proxied any; gzip_types text/plain text/css application/x-javascript text/xml application/xml application/xml+rss text/javascript; include /etc/nginx/conf.d/*.conf; include /etc/nginx/sites-enabled/*; server { listen 82.113.147.226; location /nginx_status { stub_status on; access_log off; allow 82.113.147.226; deny all; } } } Hope someone can help me with this , as I belive its minor issue, its just that "I dont see it" ty

    Read the article

  • How do I force Windows 7 to recognize my Projector?

    - by user63564
    I have a new Dell XPS with an NVIDIA GeForce GT 445M and an old (several years) Epson PowerLite Cinema 550 projector. Windows 7 refuses to recognize that the projector is connected under normal conditions (I'll get to the strange condition in a moment). Here are some things that I have already tried: Confirm that the projector continues to work well on my old Windows XP laptop. Confirm that the video cable (HDMI to HDMI) is connected Make sure the Dell laptop is plugged in to wall power at all times Reboot both the computer and the projector Click "Detect" under the "Connect to an External Display" Windows dialog (no reaction) Click "Rigorous Display Detection" under NVIDIA Control Panel (dialog: none found) Checked "Force Television Detection on startup" under "My display is not shown..." in NVIDIA Control Panel (no effect) Here's where it gets weird... My projector has three states: off, standby and on. Standby means the power switch on the back is on, but the projector is effectively off (no picture, no access to menu or controls). When I plug in the HDMI cable while the projector is in standby, Windows detects the projector! It lets me switch to Duplicate, Extend, or Project Only mode, and adjusts the resolution appropriately. A new Generic Plug-n-Play monitor shows up in my device manager. A "Seiko EPSON PJ" display shows up in my NVIDIA control panel. Then if I turn my projector on, Windows no longer recognizes the display. This is true whether I turn the projector on while the HDMI cable is plugged in, or if I unplug the HDMI cable while turning on the projector. Anyone have any ideas, because I'm completely stumped...?

    Read the article

  • Oracle 10g for Windows does not start up on system boot

    - by Mike Dimmick
    We have an Oracle 10g Enterprise Edition installation (10.2.0.1.0) on a Windows Server 2003 virtual machine. It was initially created with Virtual Server 2005 R2 SP1 but has now been migrated to Windows Server 2008 Hyper-V. The services start on system boot, but the instance does not start up. This problem was actually occurring on Virtual Server after a migration from one server to another, but I managed to fix it then with: oradim -edit -sid ORCL -startmode auto However, this now has no effect. oradim.log (in %OracleHome%\database\oradim.log) says: Thu Jun 10 14:14:48 2010 C:\oracle\product\10.2.0\db_3\bin\oradim.exe -startup -sid orcl -usrpwd * -log oradim.log -nocheck 0 Thu Jun 10 14:14:48 2010 ORA-12560: TNS:protocol adapter error sqlnet.log in the same folder has: Fatal NI connect error 12560, connecting to: (DESCRIPTION=(ADDRESS=(PROTOCOL=BEQ)(PROGRAM=oracle)(ARGV0=oracleorcl)(ARGS='(DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq)))'))(CONNECT_DATA=(SID=orcl)(CID=(PROGRAM=C:\oracle\product\10.2.0\db_3\bin\oradim.exe)(HOST=ORACLE-VM)(USER=SYSTEM)))) VERSION INFORMATION: TNS for 32-bit Windows: Version 10.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 32-bit Windows: Version 10.2.0.1.0 - Production Time: 10-JUN-2010 14:14:48 Tracing not turned on. Tns error struct: ns main err code: 12560 TNS-12560: TNS:protocol adapter error ns secondary err code: 0 nt main err code: 530 TNS-00530: Protocol adapter error nt secondary err code: 2 nt OS err code: 0 The ORA_ORCL_AUTOSTART registry value is set to TRUE, so it should be auto-starting - and you can see that it's trying to. The problem also occurs when stopping and restarting the OracleServiceORCL service. I've enabled SQL*Net tracing which shows: [10-JUN-2010 15:09:33.919] snlpcss: entry [10-JUN-2010 15:09:34.419] snlpcss: Unable to spawn Oracle oracle (DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq))) orcl, error 2. [10-JUN-2010 15:09:34.419] snlpcall: exit On a hunch that error 2 is Windows error 2 (file not found) I tried restarting the service with Process Monitor watching oradim.exe, but this appears to delay things just enough that it always works. Right now I have a horrible hack where I've created a Scheduled Task to run oradim -startup -sid ORCL when the Administrator account logs on, and set the VM to auto-logon. I'd still like to work out why it's not working.

    Read the article

  • 426 Connection closed; transfer aborted.

    - by Jiaoziren
    Hi, I have an IIS FTP set up on Windows 2003 SP2 (S1). Everyday in the early morning, a script on another server (S2) will run and initiate FTP transfer of pulling log files from S1 to S2. The FTP client we're using is built-in FTP.exe in Windows 2000 on S2. Recently we replaced S1 with a new server however we kept the IP address. There are multiple IP addresses on new S1. Ever since the new S1 was in place, the '426 Connection closed; transfer aborted.' errors haven been occuring randomly. The log indicated that the transfer started ok however the file cannot be transferred completely, as per log below: mget access*.log 200 Type set to A. 200 PORT command successful. 150 Opening ASCII mode data connection for access02232010.log(205777167 bytes). 426 Connection closed; transfer aborted. ftp: 20454832 bytes received in 283.95Seconds 72.04Kbytes/sec. The firewall monitor suggested that the connection was setup in passive mode however I've been told that MS FTP.exe doesn't support passive mode. Though I can see the response of 'entering passive mode' from server when typing in 'quote pasv'. My network admin has told me to try the transfer in active mode however I don't know how to open active mode on client side. It's getting really frustrating. Wish someone here has the right knowledge/experience could shed me a light. Cheers.

    Read the article

  • Azure can't ping or telnet VM from client

    - by Raif
    I have a VM on Azure with an instance sqlserver 2012 running on it. From my work computer and my home computer I can't get sqlserver management studio connect to it. I have looked at ALL the settings recommended in numerous articles. everything is setup correctly. endpoint 1433 Private and public sqlserver tcp enabled. sqlserver tcp listening on right port sqlserver using mixed auth windows fire wall, holes poked and then disabled on both client and VM can log in from VM using the credentials that I'm trying to use remotely further more I can't ping the dns or ip or tellnet address from my local machines. I can however hit the iis from a browser using the ip. strange. CS asked me to download MS Network Monitor, which I did and pinged and telneted. I have the results saved but can't really make heads or tails of them. CS hasn't responded yet. I can post some info here that would help. EDIT Never one to shrink from a challenge, I deleted my VM and re-did everything. Now it works although my confidence azure is somewhat shaken.

    Read the article

  • How do multiple displays work on a AMD 785G / ATI HD 4200 motherboard?

    - by aireq
    I just ordered a ASUS M4A785TD-V EVO which has the AMD 785G chipset and HD4200 integrated graphic. The board has VGA, DVI, and HDMI outputs. I'm wondering how many outputs I can run at once, and from what connectors? My guess is that I can only use the VGA, and either the DVI or the HDMI in a dual setup. But not the HDMI and the DVI at the same time. Is this correct? If I have devices plugged into both the HDMI and the DVI ports is there a way to choose between which port I want to use? I have a dual 19" monitor setup, as well as a LCD TV. I'd like to run the VGA and the DVI into my two monitors, and then the HDMI to my TV. Then when I want to watch something on the TV I'd like to be able to switch over from the DVI to the HDMI. Is this possible with out crawling under my desk and unplugging/plugging things in? Update I found the following in the manual off ASUS's website, which confirms my original suspicion that HDMI and DVI can't be used at the same time. But I'd still like to know if it's possible through software to switch between using the HDMI and DVI.

    Read the article

  • How can I filter /var/adm/wtmpx on Solaris 10?

    - by Yanick Girouard
    Some of our Solaris 10 servers are monitored using SiteScope, which uses Telnet to probe certain ports (SSH is one of them) every few minutes. This is creating an insane amount of lines in /var/adm/wtmpx, and eventually make it so big (2,5G+) that we can no longer run the last command, or that the uptime command is unable to accurately show the true uptime of the server. The error we get when trying to run the last command is this: /var/adm/wtmpx: Value too large for defined data type I have found ways we can clean this accounting log using a cron job (with the command /usr/lib/acct/fwtmp), and this works. This is not the issue. I was wondering if there would be a way to simply prevent connections from the monitoring user (in our case, user monsite) from creating entries in this accounting log at all. Is this possible, and if so, how can I do it? I've looked around and searched Google for a while, but couldn't find an answer to this question. NOTE: We are very well aware that the monitoring solution we employ is perhaps not the best one, but we cannot change it at this time. Therefore, suggesting that we change it is not pertinent to this question. If you want to read more on the Sitescope monitoring solution we employ for those servers, please see its documentation here and look for Port Monitor, and Connecting to remote UNIX servers, which explains how it works.

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • authbind, privbind or iptables REDIRECT (port 80 to 8080)?

    - by chris_l
    Hi, I'd like to run Glassfish v3 as a non-privileged user on Linux (Debian), but make it available on port 80. I'm currently doing this with iptables: iptables -t nat -I PREROUTING -p tcp -d x.x.x.x --dport 80 -j REDIRECT --to-port 8080 This works, but I wonder: If this has any significant performance impact compared to binding directly to port 80 If I could make a similar setup also work for HTTPS (or if that must run on 443) If there's a way to avoid other users from binding to port 8080 (in case my server crashes) - maybe block that port permanently to other users somehow? ...or if I should use authbind/privbind instead? Problem: I couldn't make it work with authbind or privbind so far. For authbind, I edited asadmin's last line to: exec authbind --deep "$JAVA" -Djava.net.preferIPv4Stack=true -jar ... For privbind: exec privbind -u glassfish "$JAVA" -Djava.net.preferIPv4Stack=true -jar ... (Only) with these settings, I can successfully perform a create-domain --domainport 80. This proves, that authbind and privbind actually work (the authbind version of the script is called by the glassfish user; the privbind version is called by root of course). However, in both cases I get the following exception, when starting the domain (start-domain): [#|2010-03-20T13:25:21.925+0100|SEVERE|glassfishv3.0|javax.enterprise.system.core.com.sun.enterprise.v3.server|_ThreadID=11;_ThreadName=FelixStartLevel;|Shutting down v3 due to startup exception : Permission denied: 80=com.sun.enterprise.v3.services.impl.monitor.MonitorableSelectorHandler@1fc25e5|#] I haven't found a solution for that yet (after searching the web, it seems, that this isn't so easy?) But maybe, the solution with iptables is good enough - what do you think? Thanks, Chris

    Read the article

  • Network monitoring tools with API features

    - by Kev
    We use ks-soft's Advanced Hostmonitor package to monitor around 2000 items on our network. We think it's great, the chap that supports it is fantastic, the product is fast, stable and mature but I feel as as we grow as a company it's beginning to show some friction points in the area of integration with our back office admin systems. One of the things we'd like to do is be able to add new tests to whatever monitoring tool we use via an API. For example, when orders for servers come from our retail interface, the server gets built automatically, and as part of the automated build process we'd like to automatically add new tests to the network monitoring systems. Hostmonitor has some support for this via a feature called HM Script but we're starting to encounter some speedbumps - we can't add new operators/users we can't define new "Action Profiles" - these are the actions to be taken when a test goes good or bad. What we love about hostmonitor though are the Action Profiles. For example if a Windows IIS box goes bad our action profile for a bad test does something like: Check host again (one time) Wait another 30 seconds then test again Try restart app pool on remote machine (up to two times) Send an email to ops about the restart failure Try restarting IIS on remote machine (up to four times) Page duty admin (up to 5 times - stops after duty admin ACKS alert) Page backup duty admin (5 times - stops after duty admin ACKS alert) I'm starting to look around at other network monitoring tools and I'm looking for: a comprehensive API to be able to add/remove/control tests/test "action profiles"/operators (not just plugins, we need control and admin interfaces) the ability to have quite detailed action/escalation profiles (and define these via an API) I've looked at Nagios and Icinga but Ican't seem to glean from their documentation whether we could have these features or not, or if we could, how much work would be involved to implement/customise. Can anyone provide any advice, guidance or experiences?

    Read the article

  • How to configure Hyper-V failover cluster to live migrate when dynamic memory runs out?

    - by Matt Johnson
    Appologies in advance that this is not a direct programming question, but I have a feeling that the solution involves custom powershell scripts (maybe), so this is as good a place to ask as any. I maintain a website that has a large Hyper-V cluster for SQL Servers. We are using Windows 2008 R2 SP1, and the new "dynamic memory" feature. I've already ready reviewed the Best Practices Guide, and implemented it's suggested configuration. Everything works well, except that when SQL demand increases memory pressure to expand to more memory than is available on the physical machine, the memory status goes into the "Warning" state and stays there. I assume the hypervisor is using a swapfile on the host to fulfill the memory requirement, thus slowing the virtual machine down. When this happens, there are plenty of other nodes in the cluster that have available resources. I can live-migrate the virtual server over there and everything works, and the warnings go away. Now how can I automate this? I see no menu options in either Hyper-V or the Failover Cluster Manager for performing a migration or shutdown when dynamic memory goes into the warning state. Any ideas about how to script this, or monitor it and invoke the action directly, would be helpful. If the solution involves coding, powershell would be ideal, but I could envison this as a .Net Service that monitors for this state and kicks off the migration request. I just don't know what objects are involved in doing the monitoring or kicking off the live migration. Thanks in advance.

    Read the article

  • What DBus signal is sent on system suspend?

    - by Paul Robinson
    Hello, I need to detect when a machine is going to sleep in Ubuntu 9.10 and Fedora 13. Both use UPower, so I've been looking on the "org.freedesktop.UPower" DBus bus for such signals. I've been listening for the "sleeping" signal on the UPower bus with the following command: dbus-monitor --system "type='signal',interface='org.freedesktop.UPower',member='Sleeping'" When I sleep the machine (either by closing the lid, selecting "shutdown - suspend" or sending a DBus message) I don't see a "sleeping" event. I notice that the "Sleeping" event is sent when the "org.freedesktop.UPower.AboutToSleep" method is invoked. I can do this manually by calling: dbus-send --print-reply --system --dest=org.freedesktop.UPower /org/freedesktop/UPower org.freedesktop.UPower.AboutToSleep And I notice the "sleeping" signal is fired. My understanding is that anything that sleeps the PC must send the "AboutToSleep" signal before hand. It doesn't seem like this is happening. I've tried these steps on both Fedora 13 and Ubuntu 9.10 and I see the same results. Can anyone explain what's happening or provide me with an alternative DBus signal to listen for? Many thanks, Paul

    Read the article

  • Automatically check for Security Updates on CentOS or Scientific Linux?

    - by Stefan Lasiewski
    We have machines running RedHat-based distros such as CentOS or Scientific Linux. We want the systems to automatically notify us if there are any known vulnerabilities to the installed packages. FreeBSD does this with the ports-mgmt/portaudit port. RedHat provides yum-plugin-security, which can check for vulnerabilities by their Bugzilla ID, CVE ID or advisory ID. In addition, Fedora recently started to support yum-plugin-security. I believe this was added in Fedora 16. Scientific Linux 6 did not support yum-plugin-security as of late 2011. It does ship with /etc/cron.daily/yum-autoupdate, which updates RPMs daily. I don't think this handles Security Updates only, however. CentOS does not support yum-plugin-security. I monitor the CentOS and Scientific Linux mailinglists for updates, but this is tedious and I want something which can be automated. For those of us who maintain CentOS and SL systems, are there any tools which can: Automatically (Progamatically, via cron) inform us if there are known vulnerabilities with my current RPMs. Optionally, automatically install the minimum upgrade required to address a security vulnerability, which would probably be yum update-minimal --security on the commandline? I have considered using yum-plugin-changelog to print out the changelog for each package, and then parse the output for certain strings. Are there any tools which do this already?

    Read the article

  • Building new computer, turns on, but no post

    - by addybojangles
    Pardon my ignorance here, finally decided to put together a computer and egads. I purchased a new motherboard, power supply, processor, video card and memory. ASUS M4A79XTD EVO AM3 AMD 790X ATX AMD Motherboard OCZ Fatal1ty OCZ550FTY 550W ATX12V v2.2 / EPS12V SLI Ready 80 PLUS Certified Modular Active PFC Power Supply AMD Phenom II X4 965 Black Edition Deneb 3.4GHz 4 x 512KB L2 Cache 6MB L3 Cache Socket AM3 125W Quad-Core Processor XFX HD-577A-ZNFC Radeon HD 5770 (Juniper XT) 1GB 128-bit GDDR5 PCI Express 2.0 x16 HDCP Ready CrossFireX Support Video Card G.SKILL 4GB (2 x 2GB) 240-Pin DDR3 SDRAM DDR3 1600 (PC3 12800) Dual Channel Kit Desktop Memory Model F3-12800CL9D-4GBNQ (originally had links for you guys, but I lack the rep, sorry!!) And I've got it all in the tower. I put in power supply, installed processor on motherboard, installed heatsink, put in ram, and I am using an older IDE hard disk. When I start the computer, the monitor tells me "check signal cable." As far as I can tell, the heatsink on the processor is spinning, the power supply is on (obviously), and the green LED on the motherboard is on. I originally only had the bigger output plugged in to the motherboard (what I saw in a YouTube vid as well as the mobo instructions), but after doing some research, it said plug in the other ATX power supply. Which I did. And trying to power the computer results in nothing. No beeps on startup, no post, anyone have any ideas? Your ideas and help is greatly appreciated.

    Read the article

  • Migrate installation from one HDD to another?

    - by dougoftheabaci
    I have a server with a 64 GB SSD inside. It runs just fine, but occasionally there's a hiccup that causes it to nearly fill up. When that happens my server starts to lockup and generally misbehave. I'm looking to buy a bigger SSD (either 128 GB or 256 GB) but I'm a bit unsure of how best to make the transition. For a start, I don't have an external monitor. If I need one I'll have to borrow it from work. Most of the time I just SSH into the server from my iMac. The only solution I can think of would be to buy two FW800 2.5" cases, boot from the 64 GB SSD and clone it to the 128 GB SSD. Seem a bit excessive but it might be my best option. I do have more than one SATA port on my server, but they're all currently being use for storage drives. They don't mount by default, so I could unplug them and just have the two SSDs and do the whole thing via SSH. This is another option I'm considering. My main concern with either is how best to make sure everything goes across. I want a carbon copy of the first one onto the second. This is especially important because I have a ZFS volume (my storage) and I'm a bit unfamiliar with how to move everything across. I could just start fresh and reinstall everything on the SSD, but that seems like extra trouble I don't need. So any advice on how best to achieve my goals would be appreciated. Thanks! Server is running Ubuntu Server 12.04. The iMac has 10.8.1.

    Read the article

< Previous Page | 237 238 239 240 241 242 243 244 245 246 247 248  | Next Page >