Search Results

Search found 7387 results on 296 pages for 'master detail'.

Page 243/296 | < Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >

  • Migrate from MySQL to PostgreSQL on Linux (Kubuntu)

    - by Dave Jarvis
    Storyline Trying to migrate a database from MySQL to PostgreSQL. All the documentation I have read covers, in great detail, how to migrate the structure. I have found very little documentation on migrating the data. The schema has 13 tables (which have been migrated successfully) and 9 GB of data. MySQL version: 5.1.x PostgreSQL version: 8.4.x I want to use the R programming language to analyze the data using SQL select statements; PostgreSQL has PL/R, but MySQL has nothing (as far as I can tell). A long time ago in a galaxy far, far away... Create the database location (/var has insufficient space; also dislike having the PostgreSQL version number everywhere -- upgrading would break scripts!): sudo mkdir -p /home/postgres/main sudo cp -Rp /var/lib/postgresql/8.4/main /home/postgres sudo chown -R postgres.postgres /home/postgres sudo chmod -R 700 /home/postgres sudo usermod -d /home/postgres/ postgres All good to here. Next, restart the server and configure the database using these installation instructions: sudo apt-get install postgresql pgadmin3 sudo /etc/init.d/postgresql-8.4 stop sudo vi /etc/postgresql/8.4/main/postgresql.conf Change data_directory to /home/postgres/main sudo /etc/init.d/postgresql-8.4 start sudo -u postgres psql postgres \password postgres sudo -u postgres createdb climate pgadmin3 Use pgadmin3 to configure the database and create a schema. A New Hope The episode began in a remote shell known as bash, with both databases running, and the installation of a command with a most unusual logo: SQL Fairy. perl Makefile.PL sudo make install sudo apt-get install perl-doc (strangely, it is not called perldoc) perldoc SQL::Translator::Manual Extract a PostgreSQL-friendly DDL and all the MySQL data: sqlt -f DBI --dsn dbi:mysql:climate --db-user user --db-password password -t PostgreSQL > climate-pg-ddl.sql mysqldump --skip-add-locks --complete-insert --no-create-db --no-create-info --quick --result-file="climate-my.sql" --databases climate --skip-comments -u root -p The Database Strikes Back Recreate the structure in PostgreSQL as follows: pgadmin3 (switch to it) Click the Execute arbitrary SQL queries icon Open climate-pg-ddl.sql Search for TABLE " replace with TABLE climate." (insert the schema name climate) Search for on " replace with on climate." (insert the schema name climate) Press F5 to execute This results in: Query returned successfully with no result in 122 ms. Replies of the Jedi At this point I am stumped. Where do I go from here (what are the steps) to convert climate-my.sql to climate-pg.sql so that they can be executed against PostgreSQL? How to I make sure the indexes are copied over correctly (to maintain referential integrity; I don't have constraints at the moment to ease the transition)? How do I ensure that adding new rows in PostgreSQL will start enumerating from the index of the last row inserted (and not conflict with an existing primary key from the sequence)? Resources A fair bit of information was needed to get this far: https://help.ubuntu.com/community/PostgreSQL http://articles.sitepoint.com/article/site-mysql-postgresql-1 http://wiki.postgresql.org/wiki/Converting_from_other_Databases_to_PostgreSQL#MySQL http://pgfoundry.org/frs/shownotes.php?release_id=810 http://sqlfairy.sourceforge.net/ Thank you!

    Read the article

  • Why can't I play DVDs on Windows 8 Pro with Media Center Pack?

    - by ligos
    I have a laptop with Windows 8 Pro with Media Center (64 bit), but neither Media Player or Media Center can play DVDs. Have I done something wrong? Did the Feature Pack not install correctly? Should this work? Can I somehow uninstall and reinstall the Media Pack? Details So I upgraded by Windows 7 Home Premium laptop to Windows 8 Pro based on Microsoft's low pricing. I also grabbed my free upgrade to Media Pack and followed the instructions on that page to add my feature pack. Alas! I still cannot play DVDs via either Media Center or Player. Various Context Thinking I might need to re-install the pack, I found that I could no longer add any more feature packs (searching for add features settings only shows Turn Windows Features On and Off). Media Centre and Media Player are both enabled in Windows Features. I cannot see any way to remove or downgrade from the Media Pack, nor to add any more feature packs. I installed a codec pack (32bit) from Shark007, which has not allowed me to play DVDs (although did allow me to play various other media files). Media Player can play DTV recorded on another Windows 7 box, but Media Center cannot. VLC plays DVDs OK, but I'd prefer to figure out what the root cause of this problem is. There were no errors or other indications that the Media Pack failed to install; the installation itself was quite smooth. Although I have not checked my event log in detail. Before upgrading to Windows 7, I could play DVDs OK. Screenshots System Information, showing I have Windows 8 Pro with Media Center When playing a DVD, Media Player gives and error: The selected file has an extension that is not recognised by windows... When you click Yes, it fails saying: Windows Media Player cannot find the file... Media Center says: The file type is not recognisd and cannot be played, along with some codec related stuff. I can browse the files OK via My Computer on any video DVD.

    Read the article

  • How to connect SAN from CentOS through two iSCSI Targets

    - by garconcn
    I had asked the similar question before. This time I want to use subnet for two iSCSI Targets, hence I start a new question. I have an old Promise VTrak M500i SAN Server. It comes with 2 iSCSI ports. I want to connect to two LUNs on the SAN server through two separate Targets from CentOS 5.7 64bits server. My network setup is as follows: CentOS server: Management network - 192.168.1.1 Storage network 1 - 192.168.5.2 Storage network 2 - 192.168.6.2 Promise SAN server: Management network - 192.168.1.2 iSCSI Port 1 - 192.168.5.1 iSCSI Port 2 - 192.168.6.1 I have two Logical Drives on this SAN and they are mapped as follows: Index Initiator Name LUN Mapping 0 iqn.2011-11:backup (LD0,0) 1 iqn.2011-11:template (LD1,1) Basically, I want the traffic to iqn.2011-11:backup LUN 0 through 192.168.5.1 network the traffic to iqn.2011-11:template LUN 1 through 192.168.6.1 network I don't use MPIO, just want to separate the traffic to avoid traffic jam. How do I achieve this? I am new to SAN stuff, please explain as much detail as you can. Thank you. The following are what I am doing now. After mapping the LUN to my pre-defined Initiators, the CentOS server can discover both Targets. [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.5.1 192.168.5.1:3260,1 iscsi-1 192.168.6.1:3260,2 iscsi-1 [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.6.1 192.168.6.1:3260,2 iscsi-1 192.168.5.1:3260,1 iscsi-1 [root@centos ~]# /etc/init.d/iscsi start iscsid is stopped Starting iSCSI daemon: [ OK ] [ OK ] Setting up iSCSI targets: Logging in to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] Logging in to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] Login to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] successful. Login to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] successful. [ OK ] [root@centos ~]# iscsiadm -m session tcp: [1] 192.168.6.1:3260,2 iscsi-1 tcp: [2] 192.168.5.1:3260,1 iscsi-1 When I check the LUN mapping on the SAN server for the two Logical Drives, both LUNs are connected through Port0-192.168.5.2 with the Initiator defined in CentOS. Assigned Initiator List: Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port1-192.168.5.2 1 I assume the following is what I want: Initiator Name Alias IP Address LUN iqn.2011-11.backup centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.template centos.mydomain.com Port0-192.168.6.2 1

    Read the article

  • Apache2 cgi's crash on odbc db access (but run fine from shell)

    - by Martin
    Problem overview (details below): I'm having an apache2 + ruby integration problem when trying to connect to an ODBC data source. The main problem boils down to the fact that scripts that run fine from an interactive shell crash ruby on the database connect line when run as a cgi from apache2. Ruby cgi's that don't try to access the ODBC datasource work fine. And (again) ruby scripts that connect to a database with ODBC do fine when executed from the command line (or cron). This behavior is identical when I use perl instead of ruby. So, the issue seems to be with the environment provided for ruby (perl) by apache2, but I can't figure out what is wrong or what to do about it. Does anyone have any suggestions on how to get these cgi scripts to work properly? I've tried many different things to get this to work, and I'm happy to provide more detail of any aspect if that will help. Details: Mac OS X Server 10.5.8 Xserve 2 x 2.66 Dual-Core Intel Xeon (12 GB) Apache 2.2.13 ruby 1.8.6 (2008-08-11 patchlevel 287) [universal-darwin9.0] ruby-odbc 0.9997 dbd-odbc (0.2.5) dbi (0.4.3) mod_ruby 1.3.0 Perl -- 5.8.8 DBI -- 1.609 DBD::ODBC -- 1.23 odbc driver: DataDirect SequeLink v5.5 (/Library/ODBC/SequeLink.bundle/Contents/MacOS/ivslk20.dylib) odbc datasource: FileMaker Server 10 (v10.0.2.206) ) a minimal version of a script (anonymized) that will crash in apache but run successfully from a shell: #!/usr/bin/ruby require 'cgi' require 'odbc' cgi = CGI.new("html3") aConnection = ODBC::connect('DBFile', "username", 'password') aQuery = aConnection.prepare("SELECT zzz_kP_ID FROM DBTable WHERE zzz_kP_ID = 81044") aQuery.execute aRecord = aQuery.fetch_hash.inspect aQuery.drop aConnection.disconnect # aRecord = '{"zzz_kP_ID"=>81044.0}' cgi.out{ cgi.html{ cgi.body{ "<pre>Primary Key: #{aRecord}</pre>" } } } Example of running this from a shell: gamma% ./minimal.rb (offline mode: enter name=value pairs on standard input) Content-Type: text/html Content-Length: 134 <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2 Final//EN"><HTML><BODY><pre>Primary Key: {"zzz_kP_ID"=>81044.0}</pre></font></BODY></HTML>% gamma% ) typical crash log lines: Dec 22 14:02:38 gamma ReportCrash[79237]: Formulating crash report for process perl[79236] Dec 22 14:02:38 gamma ReportCrash[79237]: Saved crashreport to /Library/Logs/CrashReporter/perl_2009-12-22-140237_HTCF.crash using uid: 0 gid: 0, euid: 0 egid: 0 Dec 22 14:03:13 gamma ReportCrash[79256]: Formulating crash report for process perl[79253] Dec 22 14:03:13 gamma ReportCrash[79256]: Saved crashreport to /Library/Logs/CrashReporter/perl_2009-12-22-140311_HTCF.crash using uid: 0 gid: 0, euid: 0 egid: 0

    Read the article

  • How to tell if a freebsd jail is up to date?

    - by Martin Torhage
    I've set up a "Service Jail" in FreeBSD 8.0 according to the FreeBSD Handbook (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html). After upgrading the host to the latest patch level and then performed a jail-upgrade, freebsd-fetch still reports that there are files in need of an update in the jail. Is this expected? Then how do I know if a jail is up to date? This is what I've done in more detail: After the initial setup of the jail freebsd-update fetch reported that there were no updates available neither in the host system nor in the jail. This was expected. A while later freebsd-update fetch reported that the following files where in need of an update both in the host and in the jail. /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a I updated the host and followed the upgrade guide for the jail (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html#JAILS-SERVICE-JAILS-UPGRADING). freebsd-update fetch now reports that there are no updates available in the host but the following is the output from freebsd-update fetch in the jail: [root@bb /]# freebsd-update fetch Looking up update.FreeBSD.org mirrors... 3 mirrors found. Fetching metadata signature for 8.0-RELEASE from update5.FreeBSD.org... done. Fetching metadata index... done. Inspecting system... done. Preparing to download files... done. The following files are affected by updates, but no changes have been downloaded because the files have been modified locally: /var/db/mergemaster.mtree The following files will be updated as part of updating to 8.0-RELEASE-p2: /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a Shouldn't freebsd-update know that the jail is up to date or have I failed upgrading it? How am I supposed to know if a jail is up to date if freebsd-update can't tell? I'm sure I ran make cleandir twice before make buildworld. TIA

    Read the article

  • missing files after reassemble of RAID-5

    - by Kris_R
    I had to open my file-server's housing on Sunday to replace a faulty fan. What I didn't see was that one of the sata-cables was not properly connected. The 1st thing I did after a reboot was a check of the RAID status and it showed immediately that one drive is missing. Till this moment the device was not used (however it was mounted, so I'm not 100% sure that system did nothing). I stopped md0 and re-plugged the cable: mdadm --stop /dev/md0 poweroff After another reboot I checked the removed drive: mdadm --examine /dev/sdd1 ... Checksum : 3276bc1d - correct Events : 315782 Layout : left-symmetric Chunk Size : 32K Number Major Minor RaidDevice State this 0 8 49 0 active sync /dev/sdd1 0 0 8 49 0 active sync /dev/sdd1 1 1 8 65 1 active sync /dev/sde1 2 2 8 33 2 active sync /dev/sdc1 3 3 8 17 3 active sync /dev/sdb1 I was a bit surprised that it was shown as active (even if earlier mdadm said, that this device was removed from array) and its checksum was OK. I recreated RAID with: mdadm --assemble /dev/md0 --scan The command mdadm --detail /dev/md0 showed that all drives were running and system was in "clean" state. I mounted the device md0 and then came hic-cup. I wanted to work on one of the last files that I had been using before all the situation and it was not there. In another place I missed actually all files from the directory where I was working. As far as I can see most of the files that are older than a few days are intact but some newer ones are missing. Now the big question: what would be your advice? Is there a way to get these data? I thought about removing the drive that was earlier labeled by mdadm and rebuild array with another empty HDD. I've found that after re-assemble the "broken" drive has another label (changed from sdd to sdb). Can this have influence on rebuilt process? If yes, how to reassemble the array properly? I'm sure the SATA-cables are connected still in the same order to the controller. p.s. Please no advises like "restore from backup". I'm doing back-ups on Sunday's night and this happened in the late afternoon, so backup is not really options for me. p.s.s. I asked this question on Unix&Linux but no answer came up during last two days. I'm getting quite anxious. Sorry for duplicating if any of you reading the other forum.

    Read the article

  • freebsd-update reports an upgraded jail as not upgraded

    - by Martin Torhage
    I've set up a "Service Jail" in FreeBSD 8.0 according to the FreeBSD Handbook (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html). After upgrading the host to the latest patch level and then performed a jail-upgrade, freebsd-fetch still reports that there are files in need of an update in the jail. Is this expected? Then how do I know if a jail is up to date? This is what I've done in more detail: After the initial setup of the jail freebsd-update fetch reported that there were no updates available neither in the host system nor in the jail. This was expected. A while later freebsd-update fetch reported that the following files where in need of an update both in the host and in the jail. /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a I updated the host and followed the upgrade guide for the jail (http://www.freebsd.org/doc/en_US.ISO8859-1/books/handbook/jails-application.html#JAILS-SERVICE-JAILS-UPGRADING). freebsd-update fetch now reports that there are no updates available in the host but the following is the output from freebsd-update fetch in the jail: [root@bb /]# freebsd-update fetch Looking up update.FreeBSD.org mirrors... 3 mirrors found. Fetching metadata signature for 8.0-RELEASE from update5.FreeBSD.org... done. Fetching metadata index... done. Inspecting system... done. Preparing to download files... done. The following files are affected by updates, but no changes have been downloaded because the files have been modified locally: /var/db/mergemaster.mtree The following files will be updated as part of updating to 8.0-RELEASE-p2: /usr/lib/libssl.a /usr/lib/libssl_p.a /usr/lib/libzpool.a /usr/lib32/libssl.a /usr/lib32/libssl_p.a /usr/lib32/libzpool.a Shouldn't freebsd-update know that the jail is up to date or have I failed upgrading it? How am I supposed to know if a jail is up to date if freebsd-update can't tell? I'm sure I ran make cleandir twice before make buildworld. TIA

    Read the article

  • Windows Vista: Networking can only connect "local only"

    - by Damien
    I am attempting to debug a problem on a Windows Vista laptop - not mine! Until just recently (last week or so), it was operating normally for about 4 years :) The problem is that I am having issues connecting to the local network (a basic wireless home router; more later) and the internet (via ADSL). This is both for wired [Broadcom chipset] and wireless [Intel chipset]. I will elaborate further later. To detail the network. I have three other clients (HTC phone, Ubuntu 12.04 desktop [wired] and Ubuntu 10.04 laptop [wireless]), all of whom are able to connect to the network and internet normally. A windows 7 virtual machine running on said desktop connects normally. I have tried two different wireless routers - Netgear DG834G and Netgear DGN3500. The same error mode is common to both. Updating the firmware to the latest on both routers does not help. Overall, it seems safe to say it's localised to the laptop in question. I do not have another Vista client to test with. The specific symptoms are as follows: When "connected", it says "Local Only", and says it cannot connect to the internet. This is true for both wired and wireless. It can get an IP address (192.168.0.5), and the router (192.168.0.1) reports that it can see the device. When I try to ping, I get the following results: ping 192.168.0.1 - (router) all packets lost ping 192.168.0.5 - (laptop's address) OK ping 192.168.0.4 - (desktop) all packets lost Pinging from the desktop to the problematic laptop results in "From 192.168.0.4 icmp_seq=1 Destination Host Unreachable" The most promising "fix" from trawling forums is KB928233 which does not work for me. The problem is persistent across reports (both full shutdown and hibernate) so it appears not to be sleep related. I am not a regular vista user, though I can fumble my way about a bit. Is there any other suggestions as to what I should do? Is there any further information I can provide?

    Read the article

  • How is incoming SMTP mail being delivered despite blocked port

    - by Josh
    I setup a MX mail server, everything works despite port 25 being blocked, I'm stumped as to why I am able to receive email with this setup, and what the consequences might be if I leave it this way. Here are the details: Connections to SMTP over port 25 and 587 both reliably connect over my local network. Connections to SMTP over port 25 are blocked from external IPs (the ISP is blocking the port). Connections to Submission SMTP over port 587 from external IPs are reliable. Emails sent from gmail, yahoo, and a few other addresses all are being delivered. I haven't found an email provider that fails to deliver mail to my MX. So, with port 25 blocked, I am assuming other MTA servers fallback to port 587, otherwise I can't imagine how the mail is received. I know port 25 shouldn't be blocked, but so far it works. Are there mail servers that this will not work with? Where can I find more about how this is working? -- edit More technical detail, to validate that I'm not missing something silly. Obviously in the transcript below I've replaced my actual domain with example.com. # DNS MX record points to the A record. $ dig example.com MX +short 1 example.com $ dig example.com A +short <Public IP address> # From a public server (not my ISP hosting the mail server) # We see port 25 is blocked, but port 587 is open $ telnet example.com 25 Trying <public ip>... telnet: Unable to connect to remote host: Connection refused # Let's try openssl $ openssl s_client -starttls smtp -crlf -connect example.com:25 connect: Connection refused connect:errno=111 # Again from a public server, we see port 587 is open $ telnet example.com 587 Trying <public ip>... Connected to example.com. Escape character is '^]'. 220 example.com ESMTP Postfix ehlo example.com 250-example.com 250-PIPELINING 250-SIZE 10485760 250-VRFY 250-ETRN 250-STARTTLS 250-ENHANCEDSTATUSCODES 250-8BITMIME 250-DSN 250-BINARYMIME 250 CHUNKING quit 221 2.0.0 Bye Connection closed by foreign host. Here is a portion from the mail log when receiving a message from gmail: postfix/postscreen[93152]: CONNECT from [209.85.128.49]:48953 to [192.168.0.10]:25 postfix/postscreen[93152]: PASS NEW [209.85.128.49]:48953 postfix/smtpd[93160]: connect from mail-qe0-f49.google.com[209.85.128.49] postfix/smtpd[93160]: 7A8C31C1AA99: client=mail-qe0-f49.google.com[209.85.128.49] The log shows that a connection was made to the local IP on port 25 (I'm not doing any port mapping, so it is port 25 on the public IP too). Seeing this leads me to hypothesize that the ISP block on port 25 only occurs when a connection is made from an IP address that is not known to be a mail server. Any other theories?

    Read the article

  • How to configure nginx so it works with Express?

    - by Michal Stefanow
    I'm trying to configure nginx so it proxy_pass requests to my node apps. Question on StackOverflow got many upvotes: http://stackoverflow.com/questions/5009324/node-js-nginx-and-now and I'm using config from there. (but since question is about server configuration it is supposed to be on ServerFault) Here is the nginx configuration: server { listen 80; listen [::]:80; root /var/www/services.stefanow.net/public_html; index index.html index.htm; server_name services.stefanow.net; location / { try_files $uri $uri/ =404; } location /test-express { proxy_pass http://127.0.0.1:3002; } location /test-http { proxy_pass http://127.0.0.1:3003; } } Using plain node: var http = require('http'); http.createServer(function (req, res) { res.writeHead(200, {'Content-Type': 'text/plain'}); res.end('Hello World\n'); }).listen(3003, '127.0.0.1'); console.log('Server running at http://127.0.0.1:3003/'); It works! Check: http://services.stefanow.net/test-http Using express: var express = require('express'); var app = express(); // app.get('/', function(req, res) { res.redirect('/index.html'); }); app.get('/index.html', function(req, res) { res.send("blah blah index.html"); }); app.listen(3002, "127.0.0.1"); console.log('Server running at http://127.0.0.1:3002/'); It doesn't work :( See: http://services.stefanow.net/test-express I know that something is going on. a) test-express is NOT running b) text-express is running (and I can confirm it is running via command line while ssh on the server) root@stefanow:~# service nginx restart * Restarting nginx nginx [ OK ] root@stefanow:~# curl localhost:3002 Moved Temporarily. Redirecting to /index.html root@stefanow:~# curl localhost:3002/index.html blah blah index.html I tried setting headers as described here: http://www.nginxtips.com/how-to-setup-nginx-as-proxy-for-nodejs/ (still doesn't work) proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_set_header X-NginX-Proxy true; I also tried replacing '127.0.0.1' with 'localhost' and vice versa Please advise. I'm pretty sure I miss some obvious detail and I would like to learn more. Thank you.

    Read the article

  • SQL server 2008 R2 installation error

    - by Sonia
    I have a windows 7,32 bit laptop. I am the administrator with all permissions. when I click on the SQL server 2008R2 set up file,it says : "SQL server set up has encountered the following error:Failed to retreive data for this request" click on OK. I have uninstalled all the components of SQL from control panel. I used Windows installer clean up to remove the files(which I must have not done ),but still no go. The summary.txt log says: Overall summary: Final result: Failed: see details below Exit code (Decimal): 847168662 Exit facility code: 638 Exit error code: 50326 Exit message: Failed to retrieve data for this request. Start time: 2012-05-25 14:59:15 End time: 2012-05-25 15:00:09 Requested action: RunRules Log with failure: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20120525_145905\Detail.txt Exception help link: http%3a%2f%2fgo.microsoft.com%2ffwlink%3fLinkId%3d20476%26ProdName%3dMicrosoft%2bSQL%2bServer%26EvtSrc%3dsetup.rll%26EvtID%3d50000%26ProdVer%3d10.0.5500.0%26EvtType%3d0xEF814B06%400x92D13C14 Machine Properties: Machine name: EWAN-PC Machine processor count: 4 OS version: Windows Vista OS service pack: Service Pack 1 OS region: Australia OS language: English (United States) OS architecture: x86 Process architecture: 32 Bit OS clustered: No Package properties: Description: SQL Server Database Services 2008 SQLProductFamilyCode: {628F8F38-600E-493D-9946-F4178F20A8A9} ProductName: SQL2008 Type: RTM Version: 10 SPLevel: 0 Installation location: c:\385030d65c6ff61fb9\x86\setup\ Installation edition: EXPRESS User Input Settings: ACTION: RunRules CONFIGURATIONFILE: FEATURES: HELP: False INDICATEPROGRESS: False INSTANCENAME: QUIET: False QUIETSIMPLE: False RULES: GLOBALRULES,SqlUnsupportedProductBlocker,PerfMonCounterNotCorruptedCheck,Bids2005InstalledCheck,BlockInstallSxS,AclPermissionsFacet,FacetDomainControllerCheck,SSMS_IsInternetConnected,FacetWOW64PlatformCheck,FacetPowerShellCheck X86: False Configuration file: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20120525_145905\ConfigurationFile.ini Detailed results: Rules with failures: Global rules: There are no scenario-specific rules. Rules report file: The rule result report file is not available. Exception summary: The following is an exception stack listing the exceptions in outermost to innermost order Inner exceptions are being indented Exception type: Microsoft.SqlServer.Management.Sdk.Sfc.EnumeratorException Message: Failed to retrieve data for this request. Data: HelpLink.ProdName = Microsoft SQL Server HelpLink.BaseHelpUrl = http://go.microsoft.com/fwlink HelpLink.LinkId = 20476 DisableWatson = true Stack: at Microsoft.SqlServer.Setup.Chainer.Workflow.PendingActions.InvokeActions(WorkflowObject metaDb, TextWriter loggingStream) at Microsoft.SqlServer.Setup.Chainer.Workflow.ActionEngine.RunActionQueue() at Microsoft.SqlServer.Setup.Chainer.Workflow.Workflow.RunWorkflow(HandleInternalException exceptionHandler) at Microsoft.SqlServer.Chainer.Setup.Setup.RunRequestedWorkflow() at Microsoft.SqlServer.Chainer.Setup.Setup.Run() at Microsoft.SqlServer.Chainer.Setup.Setup.Start() at Microsoft.SqlServer.Chainer.Setup.Setup.Main() Inner exception type: Microsoft.SqlServer.Configuration.Sco.ScoException Message: Attempted to perform an unauthorized operation. Data: WatsonData = HKEY_LOCAL_MACHINE@SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\Microsoft SQL Server 10 Stack: at Microsoft.SqlServer.Configuration.Sco.InternalRegistryKey.OpenSubKey(String subkey, RegistryAccess requestedAccess) at Microsoft.SqlServer.Configuration.Sco.SqlRegistryKey.OpenSubKey(String subkey, RegistryAccess requestedAccess) at Microsoft.SqlServer.Discovery.RegistryKeyExistsPropertyValueProvider.GetPropertyValue(Object[] context) at Microsoft.SqlServer.Discovery.DiscoveryEnumObject.GetPropertyValueFromProvider(IPropertyValueProvider propertyValueProvider, String machineName, Object[] context) at Microsoft.SqlServer.Discovery.ObjectInstanceSettings.IsObjectFound(String machineName, String idFilter) at Microsoft.SqlServer.Discovery.Product.FilterObjectSet(ArrayList objects, String idFilter) at Microsoft.SqlServer.Discovery.Product.GetData(EnumResult erParent) at Microsoft.SqlServer.Management.Sdk.Sfc.Environment.GetData() at Microsoft.SqlServer.Management.Sdk.Sfc.Environment.GetData(Request req, Object ci) at Microsoft.SqlServer.Management.Sdk.Sfc.Enumerator.GetData(Object connectionInfo, Request request) at Microsoft.SqlServer.Management.Sdk.Sfc.Enumerator.Process(Object connectionInfo, Request request) Inner exception type: System.UnauthorizedAccessException Message: Attempted to perform an unauthorized operation. Stack: at Microsoft.SqlServer.Configuration.Sco.InternalRegistryKey.OpenSubKey(String subkey, RegistryAccess requestedAccess) Ineed to install SQL server 2008 R2 for one of the company softwares to work. Any immediate help will be greatly appreciated. Thanks Sonia

    Read the article

  • Forms authentication failed between web server and sql server

    - by Matt Bear
    I've actually found the solution, but I'm trying to understand why it failed, and why my solution fixed the problem. We have an application that uses forms authentication between a web server and sql server, web server runs server 2008, sql server runs 2008 r2, and sql server 2008. In august the sql server was patched with .net 3.5.1, the web server was untouched, and the forms authentication continued to work. 1 week ago we virtualized the web server onto our vSphere server because of failing hardware. Afterwards the form authentication failed with event code 4005, detail code 50201, The ticket supplied was invalid (on the sql server). In fact the sql server started generating Schannel errors and began blue screening 3-4 times a day. At this point I touched the sql server for the first time(ever), the errors were non specific, any reference to them I could find had to do with either zone alarm(which we don't run), or memory errors. So I applied service pack 1, which stopped the blue screening, but did not fix the forms authentication. At this point we had a work around, so we put it on the back burner while we completed another project, and I was able to get back on it last night. First thing was to adjust some code in the webconfig file on the sql server, nothing, next was regenerate and change out the machine key, still no change. Update the DNS servers, no change. Finally I went through and installed all windows updates, two reboots, (over RDP installed a network card driver which failed, and did not have my server room key, that was fun). After that, forms authentication was working again. And the sql server stopped generating as many errors, I've gotten two schannel errors since then. In short, forms authentication began failing when the web server was cloned onto a virtual machine, which caused the sql server to blue sceen? and forms authentication to fail. And could only be fixed by applying patches to the sql server?(I'm wishing I had patched the servers one at a time so I could know for sure which patch on which server fixed it). My question is why did it fail, and why did patching fix it? I hate fixing something without fully understanding the why and how.

    Read the article

  • Video memory buswidth vs video memory Bandwidth

    - by Mixxiphoid
    My current video card (9600GT) is dying and I'm searching for a new video card. Between acquiring my current one and now, I got a lot more knowledge about hardware and I want to use that to pick my new card. So I decided to not just buy some popular card blindly, but to search for a card able to handle my hardware requirements. I searched the specs at the NVidia site for the GT640 and was confused by the memory section and some questions raised. My current card's memory bus width is 256bit and has 1GB of memory. I checked Google about the importance of bus width. And all the links basically said the same 'The higher the number the more potential simultaneously traffic can be transferred'. This was already clear to me, yet there are currently a lot of new cards which are considered better than my current one with a lower bus width. To go in more detail about my question I copied the memory info from the NVidia site: GT 640 GT640 GDDR5 Memory Specs: Memory Clock 1.8 Gbps 5.0 Gbps Standard Memory Config 2048 MB 1024 MB Memory Interface DDR3 GDDR5 Memory Interface Width 128-bit 64-bit Memory Bandwidth (GB/sec) 28.5 40.0 What puzzled me is that the Memory Bandwidth seems to me the most important part, yet the lower bus width has the higher 'performance'. Is this due to the fact the memory interface is GDDR5 and is therefore able to have a higher memory clock speed (5Gbps)? If I am to buy a new video card, should I check the bus width? Memory clock? Bandwith? Amount of memory? My current card ahs 1GB memory, so I was searching for a 2GB memory card, but now I'm not so sure any more whether that is really 'better'. My main question: To me it seems that memory performance is made up by the combination of bus width and frequency. Is this true? If yes, why are there so many sites telling me I need to get a card with a high bus width? If no, then what IS important when it goes about memory performance on a video card. NOTE: The memory bandwidth is (almost) never displayed on vendor sites. How can I determine which card is better without knowing the bandwith?

    Read the article

  • Windows DHCP Server - get notification when a non-AD joined device gets an IP address

    - by TheCleaner
    SCENARIO To simplify this down to it's easiest example: I have a Windows 2008 R2 standard DC with the DHCP server role. It hands out IPs via various IPv4 scopes, no problem there. WHAT I'D LIKE I would like a way to create a notification/eventlog entry/similar whenever a device gets a DHCP address lease and that device IS NOT a domain joined computer in Active Directory. It doesn't matter to me whether it is custom Powershell, etc. Bottom line = I'd like a way to know when non-domain devices are on the network without using 802.1X at the moment. I know this won't account for static IP devices. I do have monitoring software that will scan the network and find devices, but it isn't quite this granular in detail. RESEARCH DONE/OPTIONS CONSIDERED I don't see any such possibilities with the built in logging. Yes, I'm aware of 802.1X and have the ability to implement it long-term at this location but we are some time away from a project like that, and while that would solve network authentication issues, this is still helpful to me outside of 802.1X goals. I've looked around for some script bits, etc. that might prove useful but the things I'm finding lead me to believe that my google-fu is failing me at the moment. I believe the below logic is sound (assuming there isn't some existing solution): Device receives DHCP address Event log entry is recorded (event ID 10 in the DHCP audit log should work (since a new lease is what I'd be most interested in, not renewals): http://technet.microsoft.com/en-us/library/dd759178.aspx) At this point a script of some kind would probably have to take over for the remaining "STEPS" below. Somehow query this DHCP log for these event ID 10's (I would love push, but I'm guessing pull is the only recourse here) Parse the query for the name of the device being assigned the new lease Query AD for the device's name IF not found in AD, send a notification email If anyone has any ideas on how to properly do this, I'd really appreciate it. I'm not looking for a "gimme the codez" but would love to know if there are alternatives to the above list or if I'm not thinking clear and another method exists for gathering this information. If you have code snippets/PS commands you'd like to share to help accomplish this, all the better.

    Read the article

  • Configured MySQL for SSL , but SLL is still not in use..!

    - by Sunrays
    I configured SSL for MySQL using the following script. #!/bin/bash # mkdir -p /root/abc/ssl_certs cd /root/abc/ssl_certs # echo "--> 1. Create CA cert, private key" openssl genrsa 2048 > ca-key.pem echo "--> 2. Create CA cert, certificate" openssl req -new -x509 -nodes -days 1000 -key ca-key.pem > ca-cert.pem echo "--> 3. Create Server certificate, key" openssl req -newkey rsa:2048 -days 1000 -nodes -keyout server-key.pem > server-req.pem echo "--> 4. Create Server certificate, cert" openssl x509 -req -in server-req.pem -days 1000 -CA ca-cert.pem -CAkey ca-key.pem -set_serial 01 > server-cert.pem echo "" echo echo "" echo "--> 5. Create client certificate, key. Use DIFFERENT common name then server!!!!" echo "" openssl req -newkey rsa:2048 -days 1000 -nodes -keyout client-key.pem > client-req.pem echo "6. Create client certificate, cert" openssl x509 -req -in client-req.pem -days 1000 -CA ca-cert.pem -CAkey ca-key.pem -set_serial 01 > client-cert.pem exit 0 The following files were created: ca-key.pem ca-cert.pem server-req.pem server-key.pem server-cert.pem client-req.pem client-key.pem client-cert.pem Then I combined server-cert.pem and client-cert.pem into ca.pem (I read in a post to do so..) I created a ssl user in MySQL: GRANT ALL ON *.* to sslsuer@hostname IDENTIFIED BY 'pwd' REQUIRE SSL; Next I added the following in my.cnf [mysqld] ssl-ca = /root/abc/ssl_certs/ca.pem ssl-cert = /root/abc/ssl_certs/server-cert.pem ssl-key = /root/abc/ssl_certs/server-key.pem After restarting the server,I connected to mysql but SSL was still not in use :( mysql -u ssluser -p SSL: Not in use Even the have_ssl parameter was still showing disabled.. :( mysql> show variables like '%ssl%'; +---------------+---------------------------------------------+ | Variable_name | Value | +---------------+---------------------------------------------+ | have_openssl | DISABLED | | have_ssl | DISABLED | | ssl_ca | /root/abc/ssl_certs/ca.pem | | ssl_capath | | | ssl_cert | /root/abc/ssl_certs/server-cert.pem | | ssl_cipher | | | ssl_key | /root/abc/ssl_certs/server-key.pem | +---------------+---------------------------------------------+ Have I missed any step, or whats wrong.. Answers with missed steps in detail will be highly appreciated..

    Read the article

  • WIndows 7 cannot boot - bootrec reports FS not found or corrupt

    - by purecharger
    For 3 days now I've been unable to boot into my Windows 7 partition, and all my research has been to no avail. I'm hoping someone here has more ideas on how to fix this. When I boot up now, I get the black screen with BCD error that says theres no valid file system or it may be corrupt (pardon my lack of detail, no copy/paste is available then). When I boot with the Windows 7 disc and go into repair tools, no operating system is found, and attempting to automatically repair the problem fails with Unknown Operating System (Unknown Disk) or something similar. When I drop into the command prompt, I am able to see and navigate my C:\ drive without issue. I attempt to use bootrec: C:\> bootrec /ScanOS Finds C:\Windows as a system partition. C:\> bootrec /RebuildBCD Fails with volume does not contain a recognized file system. please make sure that all required file system drivers are loaded and that the volume is not corrupted. So then I attempt to fix the bootsector: C:\> bootsect /nt60 C: /force Which completes successfully (sorry, no output..) Upon rebooting, I have the same problem. I've also tried all of the above after making my Windows partition active: C:\> diskpart DISKPART> select disk 1 DISKPART> select partition 1 DISKPART> active DISKPART> exit Then bootrec as above, both with and without a reboot after the DISKPART commands. Then I've also tried rebuilding the BCD store by hand: set systemdrive=C: set tempbcd=C:\boot\bcd.temp set tempfile=C:\boot\temp.txt bcdedit -createstore %tempbcd% bcdedit.exe -store %tempbcd% -create {bootmgr} -d "Windows Boot Manager" bcdedit -store %tempbcd% -create -d "Windows Vista" -application osloader>%tempfile% set /p winvistaguid= <%tempfile% set winvistaguid=%winvistaguid:~10,38% bcdedit -store %tempbcd% -set %winvistaguid% osdevice partition=%systemdrive% bcdedit -store %tempbcd% -set %winvistaguid% device partition=%systemdrive% bcdedit -store %tempbcd% -set %winvistaguid% path \Windows\system32\winload.exe bcdedit -store %tempbcd% -set %winvistaguid% systemroot \Windows bcdedit -import %tempbcd% However on the import, I get my familiar friendly message: volume does not contain a recognized file system. please make sure that all required file system drivers are loaded and that the volume is not corrupted I'm at my wits end here, and I cannot understand why Windows refuses to see this as a valid install. When I list the disk/partition in DISKPART, it shows up as NTFS and "Healthy", and I can navigate the directory structure from DOS with no problems. I really, really do not want to reformat and reinstall. I know this problem can be solved!

    Read the article

  • How to get wireless working (properly) with Sitecom Wireless USB micro adapter 300N on Windows 7?

    - by Timo
    The question says it all, but more detail follows ;) I've got a new computer that runs Windows 7 64-bits (Home Edition) and I'd like to connect it to my wireless home network (Sitecom wireless gigabit router 300N wl-352 v1 002) with a Sitecom wireless USB micro adaptapter 300 wl-352 V2 001. After installing the router (i.e. connected to the modem and power) and ensuring that wireless is indeed enabled, I've installed the driver of the USB adapter on the new computer described above. After the installation (drivers and utility on CD) completes successfull I rebooted my computer and inserted the USB adapter. After discovering the right network and connecting to it using the network key, a connection is succesfully made. (Using the Sitecom 300N USB Wireless LAN utility). In the LAN utility I can see that the signal strength is approximately 50% and connection quality is approximately 80%. Judging from these numbers I assumed that all was fine and started to use the connection (reading news on nu.nl, a dutch news site), but noticed that the connection was lost several times in a very short time span, but each time the connections was resumed, resulting in the 50/80 percent numbers described above. However, the website was not loaded completely and often a timeout would be reported. When inspecting the drivers through Device Management (Windows' Apparaatbeheer in dutch) there were no errors/warnings; everything seemed to be in order. In an attempt to solve this, I downloaded the latest drivers for the USB adapter, but the problems remained. Finally I tried to connect the computer with a Siemens Gigaset USB Adapter 108. This process was a troublesome since I had to download a driver (from the site above) and tell Windows (7) to use the Windows Vista driver when installing the new hardware, since there is (was) no Windows 7 driver available. This resulted in a usable connection, although not very stable when reconfiguring the router. Which took the form of selecting a different wireless channel on the router, even using the Sitecom utility mentioned above to check if there were other networks communicating on that channel (and thus picking a channel that was not used by other networks). Again no result when changing back to the Sitecom USB adapter. Note that this means (I think) that I could use the internet connection with the Siemens adapter, meaning the problem was not in the router. So: How to get wireless working (properly) with Sitecom Wireless USB micro adapter 300N on Windows 7? PS Sorry, but should be able to post one link, while I had links in place for the USB adapter, router and the siemens adapter in place as well, but I'm not (yet) allowed to post these... (The site says I can post one link, but only when no links are present will it allow me to post the question...)

    Read the article

  • How to get an inactive RAID device working again?

    - by Jonik
    After booting, my RAID1 device (/dev/md_d0 *) sometimes goes in some funny state and I cannot mount it. * Originally I created /dev/md0 but it has somehow changed itself into /dev/md_d0. # mount /opt mount: wrong fs type, bad option, bad superblock on /dev/md_d0, missing codepage or helper program, or other error (could this be the IDE device where you in fact use ide-scsi so that sr0 or sda or so is needed?) In some cases useful info is found in syslog - try dmesg | tail or so The RAID device appears to be inactive somehow: # cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md_d0 : inactive sda4[0](S) 241095104 blocks # mdadm --detail /dev/md_d0 mdadm: md device /dev/md_d0 does not appear to be active. Question is, how to make the device active again (using mdmadm, I presume)? (Other times it's alright (active) after boot, and I can mount it manually without problems. But it still won't mount automatically even though I have it in /etc/fstab: /dev/md_d0 /opt ext4 defaults 0 0 So a bonus question: what should I do to make the RAID device automatically mount at /opt at boot time?) This is an Ubuntu 9.10 workstation. Background info about my RAID setup in this question. Edit: My /etc/mdadm/mdadm.conf looks like this. I've never touched this file, at least by hand. # by default, scan all partitions (/proc/partitions) for MD superblocks. # alternatively, specify devices to scan, using wildcards if desired. DEVICE partitions # auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes # automatically tag new arrays as belonging to the local system HOMEHOST <system> # instruct the monitoring daemon where to send mail alerts MAILADDR <my mail address> # definitions of existing MD arrays # This file was auto-generated on Wed, 27 Jan 2010 17:14:36 +0200 In /proc/partitions the last entry is md_d0 at least now, after reboot, when the device happens to be active again. (I'm not sure if it would be the same when it's inactive.) Resolution: as Jimmy Hedman suggested, I took the output of mdadm --examine --scan: ARRAY /dev/md0 level=raid1 num-devices=2 UUID=de8fbd92[...] and added it in /etc/mdadm/mdadm.conf, which seems to have fixed the main problem. After changing /etc/fstab to use /dev/md0 again (instead of /dev/md_d0), the RAID device also gets automatically mounted!

    Read the article

  • Raid1 with active and spare partition

    - by Daniel Baron
    I am having the following problem with a RAID1 software raid partition on my Ubuntu system (10.04 LTS, 2.6.32-24-server in case it matters). One of my disks (sdb5) reported I/O errors and was therefore marked faulty in the array. The array was then degraded with one active device. Hence, I replaced the harddisk, cloned the partition table and added all new partitions to my raid arrays. After syncing all partitions ended up fine, having 2 active devices - except one of them. The partition which reported the faulty disk before, however, did not include the new partition as an active device but as a spare disk: md3 : active raid1 sdb5[2] sda5[1] 4881344 blocks [2/1] [_U] A detailed look reveals: root@server:~# mdadm --detail /dev/md3 [...] Number Major Minor RaidDevice State 2 8 21 0 spare rebuilding /dev/sdb5 1 8 5 1 active sync /dev/sda5 So here is the question: How do I tell my raid to turn the spare disk into an active one? And why has it been added as a spare device? Recreating or reassembling the array is not an option, because it is my root partition. And I can not find any hints to that subject in the Software Raid HOWTO. Any help would be appreciated. Current Solution I found a solution to my problem, but I am not sure that this is the actual way to do it. Having a closer look at my raid I found that sdb5 was always listed as a spare device: mdadm --examine /dev/sdb5 [...] Number Major Minor RaidDevice State this 2 8 21 2 spare /dev/sdb5 0 0 0 0 0 removed 1 1 8 5 1 active sync /dev/sda5 2 2 8 21 2 spare /dev/sdb5 so readding the device sdb5 to the array md3 always ended up in adding the device as a spare. Finally I just recreated the array mdadm --create /dev/md3 --level=1 -n2 -x0 /dev/sda5 /dev/sdb5 which worked. But the question remains open for me: Is there a better way to manipulate the summaries in the superblock and to tell the array to turn sdb5 from a spare disk to an active disk? I am still curious for an answer.

    Read the article

  • WIndows 7 cannot boot - bootrec reports FS not found or corrupt

    - by purecharger
    For 3 days now I've been unable to boot into my Windows 7 partition, and all my research has been to no avail. I'm hoping someone here has more ideas on how to fix this. When I boot up now, I get the black screen with BCD error that says theres no valid file system or it may be corrupt (pardon my lack of detail, no copy/paste is available then). When I boot with the Windows 7 disc and go into repair tools, no operating system is found, and attempting to automatically repair the problem fails with Unknown Operating System (Unknown Disk) or something similar. When I drop into the command prompt, I am able to see and navigate my C:\ drive without issue. I attempt to use bootrec: C:\> bootrec /ScanOS Finds C:\Windows as a system partition. C:\> bootrec /RebuildBCD Fails with volume does not contain a recognized file system. please make sure that all required file system drivers are loaded and that the volume is not corrupted. So then I attempt to fix the bootsector: C:\> bootsect /nt60 C: /force Which completes successfully (sorry, no output..) Upon rebooting, I have the same problem. I've also tried all of the above after making my Windows partition active: C:\> diskpart DISKPART> select disk 1 DISKPART> select partition 1 DISKPART> active DISKPART> exit Then bootrec as above, both with and without a reboot after the DISKPART commands. Then I've also tried rebuilding the BCD store by hand: set systemdrive=C: set tempbcd=C:\boot\bcd.temp set tempfile=C:\boot\temp.txt bcdedit -createstore %tempbcd% bcdedit.exe -store %tempbcd% -create {bootmgr} -d "Windows Boot Manager" bcdedit -store %tempbcd% -create -d "Windows Vista" -application osloader>%tempfile% set /p winvistaguid= <%tempfile% set winvistaguid=%winvistaguid:~10,38% bcdedit -store %tempbcd% -set %winvistaguid% osdevice partition=%systemdrive% bcdedit -store %tempbcd% -set %winvistaguid% device partition=%systemdrive% bcdedit -store %tempbcd% -set %winvistaguid% path \Windows\system32\winload.exe bcdedit -store %tempbcd% -set %winvistaguid% systemroot \Windows bcdedit -import %tempbcd% However on the import, I get my familiar friendly message: volume does not contain a recognized file system. please make sure that all required file system drivers are loaded and that the volume is not corrupted I'm at my wits end here, and I cannot understand why Windows refuses to see this as a valid install. When I list the disk/partition in DISKPART, it shows up as NTFS and "Healthy", and I can navigate the directory structure from DOS with no problems. I really, really do not want to reformat and reinstall. I know this problem can be solved!

    Read the article

  • Hot-swap drive got new name, can I change it on-the-fly?

    - by T.J. Crowder
    One of the HDDs in my server's RAID config failed, so I took it out of the array and had the data center hot-swap it. They've done that, but now the new drive is /dev/sdc rather than /dev/sda. I suspect — correct me if I'm wrong — that if I reboot the server, it will be /dev/sda again, so I'm hesitant to add it back to the array as /dev/sdc because I don't want to lay a trap for myself to fall into on the next reboot. I'd just as soon not reboot the server if I don't need to (if I do need to, well, too bad for me). Is there a way I can change the device name from /dev/sdc to /dev/sda without rebooting? This is on Ubuntu 10.04 LTS. It's an md array ("Linux Software RAID"), where currently one of the devices (there are a couple of them) looks like this ("degraded" because I've removed the old /dev/sda from it): # mdadm --detail /dev/md0 /dev/md0: Version : 00.90.03 Creation Time : Sun Oct 11 21:07:54 2009 Raid Level : raid1 Array Size : 97536 (95.27 MiB 99.88 MB) Used Dev Size : 97536 (95.27 MiB 99.88 MB) Raid Devices : 2 Total Devices : 1 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Thu Jun 30 09:31:16 2011 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 0 Spare Devices : 0 UUID : 496be7a5:ab9177ed:7792c71e:7dc17aa4 Events : 0.112 Number Major Minor RaidDevice State 0 8 17 0 active sync /dev/sdb1 1 0 0 1 removed Thanks, Update: Reading through the kernel md documentation, I suspect that if the name changes on reboot, it won't matter. (Good design, that.) Here's why: Boot time autodetection of RAID arrays When md is compiled into the kernel (not as module), partitions of type 0xfd are scanned and automatically assembled into RAID arrays. This autodetection may be suppressed with the kernel parameter "raid=noautodetect". As of kernel 2.6.9, only drives with a type 0 superblock can be autodetected and run at boot time. The kernel parameter "raid=partitionable" (or "raid=part") means that all auto-detected arrays are assembled as partitionable. I do have md compiled into the kernel, so I'm rebuilding the array now and will do the reboot to see what happens. Even if it works, the above doesn't answer the question I actually asked, so unless someone comes along and answers that question in the meantime (I'd be interested, even if it's not necessary for what I'm doing this very moment), I'll just delete the question to keep noise down.

    Read the article

  • C sockets, chat server and client, problem echoing back.

    - by wretrOvian
    Hi This is my chat server : #include <stdio.h> #include <stdlib.h> #include <unistd.h> #include <sys/types.h> #include <sys/socket.h> #include <netdb.h> #include <string.h> #define LISTEN_Q 20 #define MSG_SIZE 1024 struct userlist { int sockfd; struct sockaddr addr; struct userlist *next; }; int main(int argc, char *argv[]) { // declare. int listFD, newFD, fdmax, i, j, bytesrecvd; char msg[MSG_SIZE], ipv4[INET_ADDRSTRLEN]; struct addrinfo hints, *srvrAI; struct sockaddr_storage newAddr; struct userlist *users, *uptr, *utemp; socklen_t newAddrLen; fd_set master_set, read_set; // clear sets FD_ZERO(&master_set); FD_ZERO(&read_set); // create a user list users = (struct userlist *)malloc(sizeof(struct userlist)); users->sockfd = -1; //users->addr = NULL; users->next = NULL; // clear hints memset(&hints, 0, sizeof hints); // prep hints hints.ai_family = AF_INET; hints.ai_socktype = SOCK_STREAM; hints.ai_flags = AI_PASSIVE; // get srver info if(getaddrinfo("localhost", argv[1], &hints, &srvrAI) != 0) { perror("* ERROR | getaddrinfo()\n"); exit(1); } // get a socket if((listFD = socket(srvrAI->ai_family, srvrAI->ai_socktype, srvrAI->ai_protocol)) == -1) { perror("* ERROR | socket()\n"); exit(1); } // bind socket bind(listFD, srvrAI->ai_addr, srvrAI->ai_addrlen); // listen on socket if(listen(listFD, LISTEN_Q) == -1) { perror("* ERROR | listen()\n"); exit(1); } // add listfd to master_set FD_SET(listFD, &master_set); // initialize fdmax fdmax = listFD; while(1) { // equate read_set = master_set; // run select if(select(fdmax+1, &read_set, NULL, NULL, NULL) == -1) { perror("* ERROR | select()\n"); exit(1); } // query all sockets for(i = 0; i <= fdmax; i++) { if(FD_ISSET(i, &read_set)) { // found active sockfd if(i == listFD) { // new connection // accept newAddrLen = sizeof newAddr; if((newFD = accept(listFD, (struct sockaddr *)&newAddr, &newAddrLen)) == -1) { perror("* ERROR | select()\n"); exit(1); } // resolve ip if(inet_ntop(AF_INET, &(((struct sockaddr_in *)&newAddr)->sin_addr), ipv4, INET_ADDRSTRLEN) == -1) { perror("* ERROR | inet_ntop()"); exit(1); } fprintf(stdout, "* Client Connected | %s\n", ipv4); // add to master list FD_SET(newFD, &master_set); // create new userlist component utemp = (struct userlist*)malloc(sizeof(struct userlist)); utemp->next = NULL; utemp->sockfd = newFD; utemp->addr = *((struct sockaddr *)&newAddr); // iterate to last node for(uptr = users; uptr->next != NULL; uptr = uptr->next) { } // add uptr->next = utemp; // update fdmax if(newFD > fdmax) fdmax = newFD; } else { // existing sockfd transmitting data // read if((bytesrecvd = recv(i, msg, MSG_SIZE, 0)) == -1) { perror("* ERROR | recv()\n"); exit(1); } msg[bytesrecvd] = '\0'; // find out who sent? for(uptr = users; uptr->next != NULL; uptr = uptr->next) { if(i == uptr->sockfd) break; } // resolve ip if(inet_ntop(AF_INET, &(((struct sockaddr_in *)&(uptr->addr))->sin_addr), ipv4, INET_ADDRSTRLEN) == -1) { perror("* ERROR | inet_ntop()"); exit(1); } // print fprintf(stdout, "%s\n", msg); // send to all for(j = 0; j <= fdmax; j++) { if(FD_ISSET(j, &master_set)) { if(send(j, msg, strlen(msg), 0) == -1) perror("* ERROR | send()"); } } } // handle read from client } // end select result handle } // end looping fds } // end while return 0; } This is my client: #include <stdio.h> #include <stdlib.h> #include <unistd.h> #include <sys/types.h> #include <sys/socket.h> #include <netdb.h> #include <string.h> #define MSG_SIZE 1024 int main(int argc, char *argv[]) { // declare. int newFD, bytesrecvd, fdmax; char msg[MSG_SIZE]; fd_set master_set, read_set; struct addrinfo hints, *srvrAI; // clear sets FD_ZERO(&master_set); FD_ZERO(&read_set); // clear hints memset(&hints, 0, sizeof hints); // prep hints hints.ai_family = AF_INET; hints.ai_socktype = SOCK_STREAM; hints.ai_flags = AI_PASSIVE; // get srver info if(getaddrinfo(argv[1], argv[2], &hints, &srvrAI) != 0) { perror("* ERROR | getaddrinfo()\n"); exit(1); } // get a socket if((newFD = socket(srvrAI->ai_family, srvrAI->ai_socktype, srvrAI->ai_protocol)) == -1) { perror("* ERROR | socket()\n"); exit(1); } // connect to server if(connect(newFD, srvrAI->ai_addr, srvrAI->ai_addrlen) == -1) { perror("* ERROR | connect()\n"); exit(1); } // add to master, and add keyboard FD_SET(newFD, &master_set); FD_SET(STDIN_FILENO, &master_set); // initialize fdmax if(newFD > STDIN_FILENO) fdmax = newFD; else fdmax = STDIN_FILENO; while(1) { // equate read_set = master_set; if(select(fdmax+1, &read_set, NULL, NULL, NULL) == -1) { perror("* ERROR | select()"); exit(1); } // check server if(FD_ISSET(newFD, &read_set)) { // read data if((bytesrecvd = recv(newFD, msg, MSG_SIZE, 0)) < 0 ) { perror("* ERROR | recv()"); exit(1); } msg[bytesrecvd] = '\0'; // print fprintf(stdout, "%s\n", msg); } // check keyboard if(FD_ISSET(STDIN_FILENO, &read_set)) { // read data from stdin if((bytesrecvd = read(STDIN_FILENO, msg, MSG_SIZE)) < 0) { perror("* ERROR | read()"); exit(1); } msg[bytesrecvd] = '\0'; // send if((send(newFD, msg, bytesrecvd, 0)) == -1) { perror("* ERROR | send()"); exit(1); } } } return 0; } The problem is with the part where the server recv()s data from an FD, then tries echoing back to all [send() ]; it just dies, w/o errors, and my client is left looping :(

    Read the article

  • Bluetooth not detecting any devices in Windows 7

    - by underDog
    My Lenovo ThinkPad E320 Laptop running Windows 7 64bit has recently been refusing to detect any Bluetooth devices. I have tried to connect, using 'Add devices' under 'devices and printers' to two different Bluetooth mice and my HTC Wildfire android (2.2.1) phone and none of them are detected in the 'Add a device' dialog. History - Bluetooth initially seemed OK when I first got this laptop. I was able to connect to and use my android phone as a remote with no issues. I got my first Bluetooth mouse, it paired, but after each restart, or even after sleeping, it would not 're-connect' (even though it was listed under Bluetooth devices and supposedly 'working'), and I would need to remove the device and add it again. A week or two ago it stopped working all together. It is not detected at all. I gave up on the mouse and bought another (Lenovo ThinkPad brand) only to find that it was not detected either. I subsequently tested my Android phone and discovered it would not detect either. One thing of note is under 'Devices and Printers' there is listed a 'HID Keyboard Device' which under properties is listed as a 'Bluetooth HID Device'. This was not previously there before this problem started. Each time I remove it, or uninstall it from Device Manager it will quickly re-install itself, even with all my Bluetooth devices switched off. My (Google and searching this site) research of this issue has not yielded any definitive answers. I have changed the setting under Device Manager - Bluetooth - Properties - Power Management - 'Allow the computer to turn off this device to save power' to off. I have attempted to un-install and re-install the Bluetooth hardware, including the 'remove drivers' option and downloading and running the Lenovo Bluetooth installer package (found @ http://support.lenovo.com/en_US/downloads/detail.page?DocID=DS014997). Bluetooth is turned on. All items under Bluetooth properties (Discovery and Connections) are checked. I have tried changing the batteries. I'm not sure what else I can try, apart from perhaps doing a fresh install of Windows. Any suggestions?

    Read the article

  • open source knowledge base CMS system

    - by Thomi
    I'm looking for an open source knowledge base system that uses tags, rather than free-text search to identify articles (a lot like serverfault does). I've looked at twiki, which many people suggested, but haven't found what I'm looking for. Basically I want to be able to create and tag articles, and provide an easy way for anonymous users to search based on tags. Edit: OK, here's some more detail regarding what I want. Basically, all the knowledge base systems I have seen so far are a collection of articles, each article with a title. Most of them allow you to categorise articles into groups and sub-groups. Users of the system can search for information using a title search, for example "How do I print from AwesomeProduct?" - which then shows a list of any articles that match that search text. This is fine and dandy when your KB is for one version of the software product (the mythical AwesomeProduct ver 1.0). However, the development team then go ahead and create a new version (ver 2.0) that adds many new features and changes some existing features. Now, how do we support both products in the same KB? The Naive method is to copy all articles from 1.0, and update them for 2.0, adding and removing articles in 2.0 as required. We can then add text at the top of every 1.0 article that says: "this articles applies to 1.0 only, to see the 2.0 version, click here" (or something similar) The problem with articles being indexed in the system by title is that it's very hard to filter based on meta-data like version. What happens when we create version 3.0 or 4.0? The end-situation here is that you have a mess of articles. They're hard to search, hard to filter, and even harder to manage. The solution (it seems to me) is to use tags, rather than text as the article index mechanism. So articles can be tagged with a tag representing the software version, topic area etc. etc. Users can then filter based on tag - an example search might be "version_1 printing" - which straight away gives a list of articles with all these tags. So that's what I'm looking for - a KB system that uses tags, rather than text to index many articles. I'm sure I could build something with drupal, but I was hoping for something that worked out-of-the-box.

    Read the article

  • What issues ensue from having multiple versions of Office installed?

    - by Michael Sorens
    My ultimate question is embodied in the title but I thought it might be helpful to others if I detail what instigated my inquiry and my examination of the problem. To me, the first rule of software updates is Primum non nocere -- first, do no harm. So with my Windows 7 system containing both Office 2003 and Office 2010 I blithely proceeded to install this month's updates from Microsoft, containing updates for both versions of Office. While Microsoft officially does not recommend running multiple versions (see, for example, Running Multiple Versions of Microsoft Excel it is possible; I have had two versions installed for a year or more and have never run into an issue before. One thing that is always mentioned is installation order, i.e., the one you want to open files by default should be installed last. I wanted 2010 as my default so I had indeed installed 2003 first then, years later, 2010. So with this round of Windows updates, either it installed patches to 2010 before 2003, knocking out the file association, or the 2003 patch was more comprehensive, in the sense of touching the file association while the 2010 did not. In any case, after updates, double-clicking a .xls file opened 2003 rather than 2010. Web search indicated either: Use the file associations control panel to re-associate .xls files with the correct version of excel. I looked at this first, but it showed what seemed to be an unversioned "Excel" associated with .xls files so I did not check further. (This turned out to be an error on my part; more later.) Re-install versions in the desired order; I find this unreasonable. Run the repair option of the Office installer on the desired version; still seems more work than one should need. Run excel from the command line with "/regserver" on the one to be the default and "/unregserver" on the other. Good idea, but further search indicated that neither 2007 nor 2010 support "/regserver" contrary to some posts (e.g. Default Program With Multiple Versions Installed). Since this was a Windows Update issue and Microsoft provides free support for such, I inquired there as well, but succeeded only in getting the suggestion to uninstall all other versions, period; not acceptable to me. What worked for me was going back to the file associations control panel and manually selected the Office 2010 version of Excel. While it appeared no different in the control panel, it did fix the double-click issue. So if all it takes is this simple fix after an update, I can live with that. What I am wondering is: Has anyone seen any other problems related to having multiple versions of Office installed?

    Read the article

< Previous Page | 239 240 241 242 243 244 245 246 247 248 249 250  | Next Page >