  • Troubleshooting failover cluster problem in W2K8 / SQL05

    - by paulland
    I have an active/passive W2K8 (64) cluster pair, running SQL05 Standard. Shared storage is on a HP EVA SAN (FC). I recently expanded the filesystem on the active node for a database, adding a drive designation. The shared storage drives are designated as F:, I:, J:, L: and X:, with SQL filesystems on the first 4 and X: used for a backup destination. Last night, as part of a validation process (the passive node had been offline for maintenance), I moved the SQL instance to the other cluster node. The database in question immediately moved to Suspect status. Review of the system logs showed that the database would not load because the file "K:\SQLDATA\whatever.ndf" could not be found. (Note that we do not have a K: drive designation.) A review of the J: storage drive showed zero contents -- nothing -- this is where "whatever.ndf" should have been. Hmm, I thought. Problem with the server. I'll just move SQL back to the other server and figure out what's wrong.. Still no database. Suspect. Uh-oh. "Whatever.ndf" had gone into the bit bucket. I finally decided to just restore from the backup (which had been taken immediately before the validation test), so nothing was lost but a few hours of sleep. The question: (1) Why did the passive node think the whatever.ndf files were supposed to go to drive "K:", when this drive didn't exist as a resource on the active node? (2) How can I get the cluster nodes "re-syncd" so that failover can be accomplished? I don't know that there wasn't a "K:" drive as a cluster resource at some time in the past, but I do know that this drive did not exist on the original cluster at the time of resource move.

    Read the article

  • Caching Authentication Data

    - by PartlyCloudy
    Hi, I'm currently implementing a REST web service using CouchDB and RESTlet. The RESTlet layer is mainly for authentication and some minor filtering of the JSON data served by CouchDB: Clients <= HTTP = [ RESTlet <= HTTP = CouchDB ] I'm using CouchDB also to store user login data, because I don't want to add an additional database server for that purpose. Thus, each request to my service causes two CouchDB requests conducted by RESTlet (auth data + "real" request). In order to keep the service as efficent as possible, I want to reduce the number of requests, in this case redundant requests for login data. My idea now is to provide a cache (i.e.LRU-Cache via LinkedHashMap) within my RESTlet application that caches login data, because HTTP caching will probabily not be enough. But how do I invalidate the cache data, once a user changes the password, for instance. Thanks to REST, the application might run on several servers in parallel, and I don't want to create a central instance just to cache login data. Currently, I save requested auth data in the cache and try to auth new requests by using them. If a authentication fails or there is now entry available, I'll dispatch a GET request to my CouchDB storage in order to obtain the actual auth data. So in a worst case, users that have changed their data will perhaps still be able to login with their old credentials. How can I deal with that? Or what is a good strategy to keep the cache(s) up-to-date in general? Thanks in advance.

    Read the article

  • Very weird C file-handling anomaly

    - by KáGé
    Hello, I got a very weird issue that I cant figure out in my school project, which is the simulation of a simple filesystem in a human-readable textfile. Unfortunately I don't yet have enough time to translate the comments in my code or make it less gibberish, so if you are bothered by that, you don't have to help, I understand. See the code HERE. Now in drive.h, at line 574 is this part: i = getline(); #ifdef DEBUG printf("Free space in all found at %d.\n\n", i); if(drive.disk != NULL){ printf("Disk OK\n\n"); } #endif //write in data state = seekline(i); Before this it finds place for the allocation database entry in the ALL sector (see the "image files" in the mounts folder, this issue was tested on mount_30.efs-dbf), then gets the line with i = getline() fine (getline is in lglobal.h, line 39), but after that any file manipulation (in this case seekline's fseek, but if I comment that out, then the first fprintf after that) crashes the program straight away. I think the file gets somehow corrupted (though the Disk OK message appears) but can't figure out how. I've tried putting i = getline(); into comment, but it didn't make any difference. I've also tried asking at local programming forums but they didn't really help either. The last few lines of the output before it crashes: Dir written. (drive.h line 562) Seekline entered: 268 (called at drive.h line 564) Getline entered. (called at drive.h line 574) Line got: 268. Free space in all found at 268. (drive.h line 576) Seekline entered: 268 (called at drive.h line 582, note that this exact call was run successfully less than 20 lines back. This one should set the pointer to the beginning of the line it is currently in) After this it crashes. Does anyone has any idea of what causes this and how could I fix it? Thank you.

    Read the article

  • C# delegate or Func for 'all methods'?

    - by Michel
    Hi, i've read something about Func's and delegates and that they can help you to pass a method as a parameter. Now i have a cachingservice, and it has this declaration: public static void AddToCache<T>(T model, double millisecs, string cacheId) where T : class public static T GetFromCache<T>(string cacheId) where T : class So in a place where i want to cache some data, i check if it exists in the cache (with GetFromCache) and if not, get the data from somewhere, and the add it to the cache (with AddToCache) Now i want to extend the AddToCache method with a parameter, which is the class+method to call to get the data Then the declaration would be like this public static void AddToCache<T>(T model, double millisecs, string cacheId, Func/Delegate methode) where T : class Then this method could check wether the cache has data or not, and if not, get the data itself via the method it got provided. Then in the calling code i could say: AddToCache<Person>(p, 10000, "Person", new PersonService().GetPersonById(1)); AddToCache<Advert>(a, 100000, "Advert", new AdvertService().GetAdverts(3)); What i want to achieve is that the 'if cache is empty get data and add to cache' logic is placed on only one place. I hope this makes sense :) Oh, by the way, the question is: is this possible?

    Read the article

  • curl not returning content length header

    - by Michael P. Shipley
    Trying to get image file size using curl but content length header is not returned: $url ="http://www.collegefashion.net/wp-content/plugins/feed-comments-number/image.php?1263"; $fp = curl_init(); curl_setopt($fp, CURLOPT_NOBODY, true); curl_setopt($fp, CURLOPT_RETURNTRANSFER, 1); curl_setopt($fp, CURLOPT_FAILONERROR,1); curl_setopt($fp, CURLOPT_REFERER,''); curl_setopt($fp, CURLOPT_URL, $url); curl_setopt($fp, CURLOPT_HEADER,1); curl_setopt($fp, CURLOPT_USERAGENT,'Mozilla/5.0'); $body = curl_exec($fp); var_dump($body): HTTP/1.1 200 OK Date: Sun, 02 May 2010 02:50:20 GMT Server: Apache/2.0.63 (CentOS) X-Powered-By: W3 Total Cache/0.8.5.2 X-Pingback: http://www.collegefashion.net/xmlrpc.php Cache-Control: no-cache, must-revalidate Expires: Sat, 26 Jul 1997 05:00:00 GMT Content-Type: image/png It works via ssh though: curl -i http://www.collegefashion.net/wp-content/plugins/feed-comments-number/image.php?1263 HTTP/1.1 200 OK Date: Sun, 02 May 2010 03:38:43 GMT Server: Apache/2.0.63 (CentOS) X-Powered-By: W3 Total Cache/0.8.5.2 X-Pingback: http://www.collegefashion.net/xmlrpc.php Cache-Control: no-cache, must-revalidate Expires: Sat, 26 Jul 1997 05:00:00 GMT Content-Length: 347 Content-Type: image/png

    Read the article

  • Making firefox refresh images faster

    - by Earlz
    I have a thing I'm doing where I need a webpage to stream a series of images from the local client computer. I have a very simple run here: http://jsbin.com/idowi/34 The code is extremely simple setTimeout ( "refreshImage()", 100 ); function refreshImage(){ var date = new Date() var ticks = date.getTime() $('#image').attr('src','http://127.0.0.1:2723/signature?'+ticks.toString()); setTimeout ("refreshImage()", 100 ); } Basically I have a signature pad being used on the client machine. We want for the signature to show up in the web page and for them to see themselves signing it within the web page(the pad does not have an LCD to show it to them right there). So I setup a simple local HTTP server which grabs an image of what the current state of the signature pad looks like and it gets sent to the browser. This has no problems in any browser(tested in IE7, 8, and Chrome) but Firefox where it is extremely laggy and jumpy and doesn't keep with the 10 FPS rate. Does anyone have any ideas on how to fix this? I've tried creating very simple double buffering in javascript but that just made things worse. Also for a bit more information it seems that Firefox is executing the javascript at the correct framerate as on the server the requests are coming in at a constant speed. But the images are only refreshed inconsistently ranging from 5 times per second all the way down to 0 times per second(taking 2 seconds to do a refresh) Also I have tried using different image formats all with the same results. The formats I've tried include bitmaps, PNGs, and GIFs (GIFs caused a minor problem in Chrome with flicker though) Could it be possible that Firefox is somehow caching my images causing a slight lag? I send these headers though: Pragma-directive: no-cache Cache-directive: no-cache Cache-control: no-cache Pragma: no-cache Expires: 0

    Read the article

  • HTTP Headers: Max-Age vs Expires – Which One To Choose?

    - by Gopinath
    Caching of static content like images, scripts, styles on the client browser reduces load on the webservers and also improves end users browsing experience by loading web pages quickly. We can use HTTP headers Expires or Cache-Control:max-age to cache content on client browser and set expiry time for them. Expire header is HTTP/1.0 standard and Cache-Control:max-age is introduced in HTTP/1.1 specification to solve the issues and limitation with Expire  header. Consider the following headers.   Cache-Control: max-age=24560 Expires: Tue, 15 May 2012 06:17:00 GMT The first header instructs web browsers to cache the content for 24560 seconds relative to the time the content is downloaded and expire it after the time period elapses. The second header instructs web browser to expiry the content after 15th May 2011 06:17. Out of these two options which one to use – max-age or expires? I prefer max-age header for the following reasons As max-age  is a relative value and in most of the cases it makes sense to set relative expiry date rather than an absolute expiry date. Expire  header values are complex to set – time format should be proper, time zones should be appropriate. Even a small mistake in settings these values results in unexpected behaviour. As Expire header values are absolute, we need to  keep changing them at regular intervals. Lets say if we set 2011 June 1 as expiry date to all the image files of this blog, on 2011 June 2 we should modify the expiry date to something like 2012 Jan 1. This add burden of managing the Expire headers. Related: Amazon S3 Tips: Quickly Add/Modify HTTP Headers To All Files Recursively cc image flickr:rogue3w This article titled,HTTP Headers: Max-Age vs Expires – Which One To Choose?, was originally published at Tech Dreams. Grab our rss feed or fan us on Facebook to get updates from us.

    Read the article

  • Unable to run Ubuntu Software center in 12.04

    - by Noye
    I think I've tried everything found. It is on just for a second. I can't even send an error report. What should I do? thanks in advance. so this is what I get after typing software-center in terminal (sorry, not as a code): 2012-06-16 22:54:17,610 - softwarecenter.ui.gtk3.app - INFO - setting up proxy 'None' 2012-06-16 22:54:17,617 - softwarecenter.db.database - INFO - open() database: path=None use_axi=True use_agent=True 2012-06-16 22:54:18,142 - softwarecenter.backend.reviews - WARNING - Could not get usefulness from server, no username in config file 2012-06-16 22:54:18,697 - softwarecenter.db.pkginfo_impl.aptcache - INFO - aptcache.open() Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 243, in open self._cache = apt.Cache(GtkMainIterationProgress()) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 102, in __init__ self.open(progress) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 149, in open self._list.read_main_list() SystemError: E:Typ „ain“ je neznámy na riadku 2 v zozname zdrojov /etc/apt/sources.list.d/yannubuntu-boot-repair-precise.list 2012-06-16 22:54:21,916 - softwarecenter.db.enquire - ERROR - _get_estimate_nr_apps_and_nr_pkgs failed Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/enquire.py", line 115, in _get_estimate_nr_apps_and_nr_pkgs tmp_matches = enquire.get_mset(0, len(self.db), None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__' Traceback (most recent call last): File "/usr/bin/software-center", line 176, in app.run(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1358, in run self.show_available_packages(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1288, in show_available_packages self.view_manager.set_active_view(ViewPages.AVAILABLE) File "/usr/share/software-center/softwarecenter/ui/gtk3/session/viewmanager.py", line 149, in set_active_view view_widget.init_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/panes/availablepane.py", line 168, in init_view self.apps_filter) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 240, in __init__ self.build(desktopdir) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 491, in build self._build_homepage_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 266, in _build_homepage_view self._append_whats_new() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 430, in _append_whats_new whats_new_cat = self._update_whats_new_content() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 419, in _update_whats_new_content docs = whats_new_cat.get_documents(self.db) File "/usr/share/software-center/softwarecenter/db/categories.py", line 124, in get_documents nonblocking_load=False) File "/usr/share/software-center/softwarecenter/db/enquire.py", line 317, in set_query self._blocking_perform_search() File "/usr/share/software-center/softwarecenter/db/enquire.py", line 212, in _blocking_perform_search matches = enquire.get_mset(0, self.limit, None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__'

    Read the article

  • Coherence Based WebLogic Server Session Management

    - by [email protected]
    Specifications Supported Configurations WebLogic Server 10.3.2( or 10.3.1 ) Coherence 3.5.2/463 If you use other verion above, then please check the following matrix:   WebLogic Server 9.2 MP1 Weblogic Server 10.3 WebLogic Smart Update Patch ID: AJQB Patch ID: 6W2W Minimum Coherence Release Level/MetaLink Patch ID 3.4.2 Patch 2-Patch ID:8429415 3.4.2 Patch6-Patch ID:11399293 Environment Variables %COHERENCE_HOME%: coherence installation directory %DOMAIN_HOME%: weblogic domain foler. Instructions We Will create to weblogic domains: domain_a, domain_b. To configure those domains with coherence-based session management . Then the changings of session variable value in one domain will propagate to another domain. Main Steps WebLogic Server create domain_a The process is ignored copy %COHERENCE_HOME%\lib\coherence.jar to %DOMAIN_HOME%\lib startup domain deploy %COHERENCE_HOME%\lib\coherence-web-spi.war as a Shared Library repeat step 1~4 at domain_b Coherence duplicate %COHERENCE_HOME%\bin\cache-server.cmd at the same folder and rename it to web-cache-server.cmd modify web-cache-server.cmd java -server -Xms512m -Xmx512m -cp %coherence_home%/lib/coherence.jar;%coherence_home%/lib/coherence-web-spi.war -Dtangosol.coherence.management.remote=true -Dtangosol.coherence.cacheconfig=WEB-INF/classes/session-cache-config.xml -Dtangosol.coherence.session.localstorage=true com.tangosol.net.DefaultCacheServer startup web-cache-server.cmd Testing develop a web app  with OEPE or JDeveloper and implment functions: changing, viewing, listing  session variables. ( or download sample codes here ) modify weblogic.xml with following content: <?xml version="1.0" encoding="UTF-8"?> <wls:weblogic-web-app xmlns:wls=http://xmlns.oracle.com/weblogic/weblogic-web-app xmlns:xsi=http://www.w3.org/2001/XMLSchema-instance xsi:schemaLocation="http://java.sun.com/xml/ns/javaee http://java.sun.com/xml/ns/javaee/web-app_2_5.xsd http://xmlns.oracle.com/weblogic/weblogic-web-app http://xmlns.oracle.com/weblogic/weblogic-web-app/1.0/weblogic-web-app.xsd"> <wls:weblogic-version>10.3.2</wls:weblogic-version> <wls:context-root>CoherenceWeb</wls:context-root> <wls:library-ref> <wls:library-name>coherence-web-spi</wls:library-name> <wls:specification-version>1.0.0.0</wls:specification-version> <wls:exact-match>true</wls:exact-match> </wls:library-ref> </wls:weblogic-web-app> deploy the web app to domain_a and domain_b change session varaible vlaue at domain_a and check whethe if changed at domain_b References Using Oracle Coherence*Web 3.4.2 with Oracle WebLogic Server 10gR3 Oracle Coherence*Web 3.4.2 with Oracle WebLogic Server 10gR3

    Read the article

  • I changed the repository and now my ubuntu software center crashes

    - by Paul Menz
    paul@ubuntu:~$ software-center 2012-10-24 18:11:04,665 - softwarecenter.ui.gtk3.app - INFO - setting up proxy 'None' 2012-10-24 18:11:04,671 - softwarecenter.db.database - INFO - open() database: path=None use_axi=True use_agent=True 2012-10-24 18:11:05,191 - softwarecenter.backend.reviews - WARNING - Could not get usefulness from server, no username in config file 2012-10-24 18:11:05,403 - softwarecenter.ui.gtk3.app - INFO - show_available_packages: search_text is '', app is None. 2012-10-24 18:11:05,920 - softwarecenter.db.pkginfo_impl.aptcache - INFO - aptcache.open() Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 243, in open self._cache = apt.Cache(GtkMainIterationProgress()) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 102, in __init__ self.open(progress) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 149, in open self._list.read_main_list() SystemError: E:Malformed line 63 in source list /etc/apt/sources.list (dist parse) 2012-10-24 18:11:07,255 - softwarecenter.db.enquire - ERROR - _get_estimate_nr_apps_and_nr_pkgs failed Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/enquire.py", line 115, in _get_estimate_nr_apps_and_nr_pkgs tmp_matches = enquire.get_mset(0, len(self.db), None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__' Traceback (most recent call last): File "/usr/bin/software-center", line 176, in <module> app.run(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1422, in run self.show_available_packages(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1352, in show_available_packages self.view_manager.set_active_view(ViewPages.AVAILABLE) File "/usr/share/software-center/softwarecenter/ui/gtk3/session/viewmanager.py", line 154, in set_active_view view_widget.init_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/panes/availablepane.py", line 171, in init_view self.apps_filter) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 238, in __init__ self.build(desktopdir) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 511, in build self._build_homepage_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 271, in _build_homepage_view self._append_whats_new() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 450, in _append_whats_new whats_new_cat = self._update_whats_new_content() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 439, in _update_whats_new_content docs = whats_new_cat.get_documents(self.db) File "/usr/share/software-center/softwarecenter/db/categories.py", line 124, in get_documents nonblocking_load=False) File "/usr/share/software-center/softwarecenter/db/enquire.py", line 317, in set_query self._blocking_perform_search() File "/usr/share/software-center/softwarecenter/db/enquire.py", line 212, in _blocking_perform_search matches = enquire.get_mset(0, self.limit, None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__'

    Read the article

  • Cannot get Virtualbox to install properly on Ubuntu 12.04

    - by lopac1029
    I cannot get Virtualbox to install properly on my 12.04. I first went with a manual install for the .deb from the old builds section of the Virtualbox page. That .deb opened up the Software Center and installed. Then I got the error coming up of VT-x/AMD-V hardware acceleration is not available on your system. Your 64-bit guest will fail to detect a 64-bit CPU and will not be able to boot. which I can only assume was due to my Ubuntu version being 32-bit (System Details - Overview - OC type: 32-bit, right?) So I followed these instructions to remove the .deb manually, restarted my laptop, and then FOUND the actual Virtualbox install in the Software Center and installed from that (assuming it would give me the correct version I need for my system) So after all that (and then some), I'm still getting the same error when I connect to my new job's project in Virtualbox. Can anyone point me in the right direction of what to do here? This is the first time I've ever worked with Virtualbox, and no one at this company is using Ubuntu, so I'm on my own here. EDIT: Here is the direct info from running the 2 suggested commands Inspiron-1750-brick:~ $lscpu Architecture: i686 CPU op-mode(s): 32-bit, 64-bit Byte Order: Little Endian CPU(s): 2 On-line CPU(s) list: 0,1 Thread(s) per core: 1 Core(s) per socket: 2 Socket(s): 1 Vendor ID: GenuineIntel CPU family: 6 Model: 23 Stepping: 10 CPU MHz: 2100.000 BogoMIPS: 4189.45 L1d cache: 32K L1i cache: 32K L2 cache: 2048K Inspiron-1750-brick:~ $cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 6 model : 23 model name : Intel(R) Core(TM)2 Duo CPU T6500 @ 2.10GHz stepping : 10 microcode : 0xa07 cpu MHz : 1200.000 cache size : 2048 KB physical id : 0 siblings : 2 core id : 0 cpu cores : 2 apicid : 0 initial apicid : 0 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 13 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts aperfmperf pni dtes64 monitor ds_cpl est tm2 ssse3 cx16 xtpr pdcm sse4_1 xsave lahf_lm dtherm bogomips : 4189.80 clflush size : 64 cache_alignment : 64 address sizes : 36 bits physical, 48 bits virtual power management: processor : 1 vendor_id : GenuineIntel cpu family : 6 model : 23 model name : Intel(R) Core(TM)2 Duo CPU T6500 @ 2.10GHz stepping : 10 microcode : 0xa07 cpu MHz : 1200.000 cache size : 2048 KB physical id : 0 siblings : 2 core id : 1 cpu cores : 2 apicid : 1 initial apicid : 1 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 13 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm constant_tsc arch_perfmon pebs bts aperfmperf pni dtes64 monitor ds_cpl est tm2 ssse3 cx16 xtpr pdcm sse4_1 xsave lahf_lm dtherm bogomips : 4189.45 clflush size : 64 cache_alignment : 64 address sizes : 36 bits physical, 48 bits virtual power management:

    Read the article

  • Rebuilding array on 3ware 9690SA-8I

    - by Tim Jones
    I have a RAID10 (8x1TB) array on a 3ware 9690 card running on an Ubuntu 1110 server. There was a kernel update so I scheduled a reboot after which the array was inaccessible. I checked the status a drive has died in the array, but the controller has thrown the entire array into an 'inoperable' state instead of simply degraded (what's the point of the RAID now ;-). After taking out the 'dead' drive I run a quick test to find it completely functional without a bad sector to be found. I try to put the drive back in but the array still marks the disk as degraded (remembering serial number or something??) and the entire array as inoperable... So I swap it out for a known working drive (not the same capacity but higher - should still work) and initiate a rebuild with the the new drive as a replacement. This fails instantly with the error "(0x0B:0x0033): Unit busy : Failed to start Rebuild on Unit 0". The unit shouldn't be busy as it is not mounted (the card itself is listed with lshw but the array it provides is not). I'm pretty much at an impasse now, I don't understand how I can have a single drive failure on a RAID10 that makes the entire array inaccessible, degraded I could understand but inaccessible?? I don't think the controller as prior to the reboot it was completely functional.

    Read the article

  • Problem booting virtual machine after converting VMDK to VHD

    - by vg1890
    I used the VMWare VCenter Converter Standalone Client to convert a physical drive on my old PC to a virtual drive. The conversion worked fine and I ended up with a valid VMDK file. Next, I wanted to convert the VMDK to a VHD for use with Microsoft Virtual PC, since that's what I use on my new box. I used WinImage for the conversion and that worked fine, too. I can access the files from the virtual drive through WinImage. However, when I create a new virtual machine using Virtual PC and add the existing VHD file, the machine doesn't boot. The initial boot screen flashes with the amount of RAM and then the screen goes black. If I turn off the VM and reboot in safe mode I can see the drivers being loaded until eventually it gets to crcdisk.sys and hangs indefinitely. Any ideas how to fix this? I'm not opposed to starting over from scratch if there's another method to turn my physical machine into a Virtual PC VM. Thanks! EDIT - I should add that the virtual drive is a system boot drive and not a secondary drive. EDIT - I tried booting from the install CD and doing a repair. The result was that the system could not be repaired due to a "driver error."

    Read the article

  • Solaris: detect hotswap SATA disk insert

    - by growse
    What's the method used on Solaris to get the system to rescan for new disks that have been hot-plugged on a SATA controller? I've got an HP X1600 NAS which had 9 drives configred in a ZFS pool. I've added 3 disks, but the format command still only shows the original 9. When I plugged them in, I saw this: cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=12 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=11 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=10 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO But can't figure out how to get the format command to see them so I know they've been detected by the system.

    Read the article

  • How can I get my SATA DVDs working again?

    - by user269051
    My hard drive crashed (WinXPpro), so I took a C drive from a broken PC. The new C drive is Win7pro. Motherboard is MSI K8N Neo4 Platinum, with 4 hard drives installed on SATA 1-4 (nForce4 Ultra); the two DVD drives are loaded on SATA 7-8 (Silicon Image SATARAID5). I've tweaked BIOS settings every which way. The closest thing to success was when each DVD had both a CD and a DVD icon, and blinked green. No CD or DVD could be read in either drive. I assume that the problem resulted from the fact that my new C drive does not have the RAID drivers? I've tried loading from the floppy (doesn't work). I can't boot off the DVD/CD, and switching the DVD's SATA cable to the SATA 3 slot (and pulling one of the hard discs) didn't work. I'd like to be able to use the other two available SATA slots for a mirrored RAID drive, and get my DVDs working again. Any suggestions?

    Read the article

  • restoring a failed SBS 2000 box...

    - by Brad Pears
    Hi there, I read a post where you had mentioned you have had a PERC card blow up on you in an SBS box... I've got a similar situation where one of my RAID drives failed and then the power supply failed before I could replace the drive... I then replaced the power supply and the failed drive and reconfigured the RAID array. I had a recent full backup of the my Win2k SBS's C: drive stored on my SYmantec backup exec server so I installed win2K server on the c: partition and then once I had that up and running, installed the backup exec agent so as to do a restore of the entire c drive including system state. THis all worked just fine, until I had to reboot. I received an "incorrect drive configuration" error and then it hangs. I figure that likely makes sense becasue I think my RAID array is configured slightly different now in that the partitions may be sizeded ever so slightly differently now than they were before I think... Is there a way I can just restore from my backup BUT maybe exclude some of the registry and hidden boot files it wants to restore so that it is booting with the current configuration now active on that machine - not the pre blow up configuration files? I also read a post that indicated you might have to install the exact same service pack etc... etc.. before attemting a restore but that does not make sense to me being as the entire c drive contents are going to be overwritten by the restore anyway? THe basic OS install is just to be able to get the backup exec agent installed . I can;t understand why one would need to install the exact same SP level. CAn you shed some light on what I might be able to do to get this thing up and running? Thanks,Brad

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article

  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • How do I fix a super slow MacBook?

    - by MakingScienceFictionFact
    I'm running a black MacBook 4.1. Intel Core 2 Duo @ 2.4 GHz, 2 GB RAM, 250 GB hard disk drive, bus speed is 800 MHz. It's about three years old in excellent shape externally. I treat this thing like a baby. It used to run awesome, but now it's super slow at everything. I get the spinning pizza of death constantly. It takes a long time to boot up or load any program, even Safari and iTunes. iPhoto is terribly slow. The Internet doesn't work properly and it reminds me of a buggy PC. I've formatted it and re-installed Mac OS X 10.6 (with all updates), and I've done the disk repairs process. As an iOS developer this is driving me crazy, but luckily I have an iMac to work on in the day which is fast. I'm ready to format it again, but that didn't work last time. After the last format, I copied back files from an external drive so maybe the offending files were hidden in there somewhere. Here are the hard disk drive and RAM specifications. It is upgrade-able to 4 GB of RAM. Hard disk drive: The Fujitsu Mobile MHY2250BH is a 250 GB, standard hard disk drive. Its burst transfer rate is 150 Mbyte/s. This is a 5400 RPM drive and comes with an 8 MB buffer. RAM: two sticks of 1 GB DDR2 SDRAM, speed: 667 MHz.

    Read the article

  • Cannot delete flash9.ocx

    - by Kara Marfia
    Some kinda voodoo, indeed. Bought a new boot drive, and it's time to use the old drive for data. I thought I'd save some time by just wiping the unneeded system folders, instead of backing up, formatting, and restoring. Wups! I have a single Adobe file that absolutely will not be deleted. G:\Windows\SysWOW64\Macromed\Flash\flash9.ocx - though it may have started with a different file name. I'm able to rename it, oddly enough. To be clear, the drive is currently plugged in externally. So I can boot the computer, plug this drive in afterward, and immediately attempt to delete. "File in use" box reads "the action can't be completed because the file is open in another program". I'd format at this point, but it's my white whale, and I have to know if Adobe has inserted some nasty little registry hack - or whatever it is - making this impossible. Since I'm sure it'll come up, I've taken ownership of the file - and this was the trick preventing me from deleting anything else on the drive - full rights on the file permissions, you name it, I've fiddled with the file itself. I'm about to try uninstalling flash from the system drive, in case that aligns the planets properly. Sometimes I wish I were less stubborn, and could just format already.

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Power supply switch like stays off motherboard light turns on

    - by Sion
    I bought a computer at the thrift store yesterday. The computer powered on without any error beeps. Getting it back to the house determined that the CD and hard drive needed to be changed. Put in a populated hard drive to check, the computer turned on and seemed to function. Put in a new CD drive, and just put in a new Hard drive. I plugged it in to check and I noticed that the light for the power supply switch did not come on. But I did notice that the light on the motherboard is lit. and I could not turn the computer on. To help troubleshoot it I unplugged the CD and Hard drive. then re-plugged the power supply and switched it on and off. Nothing changed. Parts: Motherboard: Digital Home PSW DH deluxe Power Supply: FSP-Group FX700-GLN Did I accidentally unplug something while installing the hard drive? Is the Power supply fried somehow?

    Read the article

  • Could hybrid SSD + HDD be made with fixed internal partitions?

    - by Aaron
    I was pretty close to getting Seagate's Momentus XT but have been scared off by the many problems reported on forums and feedback sites, especially in Mac Book Pros. So I'm waiting for mk 2 with some extra flash and better reliablilty I'm assuming will come out this year. What would suit me better though is a 32+500 hybrid drive where I have more control over what is on the flash drive and what is on the disk drive. So there are 2 physical partitions within the one 2.5" hard drive enclosure which use different media internally (32GB for core files and 500GB for data and multimedia). The partitions would be locked so they can't be changed. - Or even better, the disk driver just makes them appear as two disks to the OS that share the same bus... Perhaps it's ok if the bios just sees the first drive until the OS is loaded. Is either of it technically possible? Obviously difficult to market outside of the enthusiast market. The SSD memory modules can be pretty small right, so they could even make them a card that plugs into a secondary connection on the enclosure. That would be good for computer builders as well as for upgrading and recoverability. Then future operating systems could recognise these system SSD drives and automatically install the OS + swap files on it. While placing document libraries on the larger data drive. While in the longer term HDD will probably disapear there will always be a trade off between speed, storage size and expense.

    Read the article

  • How to migrate WinXP from failing old HD to new one

    - by Péter Török
    Following this issue, we have all our important data backed up now. I also bought and installed a new replacement hard disk (WD 160GB PATA) as secondary (slave) drive. I created two primary NTFS partitions on it: a 40 GB system partition, and a 110GB data partition. In theory I could start reinstalling WinXP from scratch on the new system partition, then copying over all user data from the old drive to the new data partition. Once this is done, I could even throw away the old drive, or keep it just to see what happens. (Note: I don't want to clone the whole drive as it contains a dual boot setup with an old Linux installation which I don't need anymore, and anyway, a fresh reinstall would do WinXP good to get rid of many years' clutter.) However, I am lazy :-) The old HD is still functioning, the problem has not manifested again since. So I feel there is no need to hurry with a complete OS reinstall. What I don't know though is whether I will be able to install WinXP on the new system partition at a later stage without affecting the contents of the data partition on the same drive. If this is possible, I can just move over all our data to the new data partition to have it safe, then continue running WinXP from the old drive as long as it works. Does anyone see any problems/risks with this plan?