Search Results

Search found 48589 results on 1944 pages for 'system requirements'.

Page 256/1944 | < Previous Page | 252 253 254 255 256 257 258 259 260 261 262 263  | Next Page >

  • VB .Net - Reflection: Reflected Method from a loaded Assembly executes before calling method. Why?

    - by pu.griffin
    When I am loading an Assembly dynamically, then calling a method from it, I appear to be getting the method from Assembly executing before the code in the method that is calling it. It does not appear to be executing in a Serial manner as I would expect. Can anyone shine some light on why this might be happening. Below is some code to illustrate what I am seeing, the code from the some.dll assembly calls a method named PerformLookup. For testing I put a similar MessageBox type output with "PerformLookup Time: " as the text. What I end up seeing is: First: "PerformLookup Time: 40:842" Second: "initIndex Time: 45:873" Imports System Imports System.Data Imports System.IO Imports Microsoft.VisualBasic.Strings Imports System.Reflection Public Class Class1 Public Function initIndex(indexTable as System.Collections.Hashtable) As System.Data.DataSet Dim writeCode As String MessageBox.Show("initIndex Time: " & Date.Now.Second.ToString() & ":" & Date.Now.Millisecond.ToString()) System.Threading.Thread.Sleep(5000) writeCode = RefreshList() End Function Public Function RefreshList() As String Dim asm As System.Reflection.Assembly Dim t As Type() Dim ty As Type Dim m As MethodInfo() Dim mm As MethodInfo Dim retString as String retString = "" Try asm = System.Reflection.Assembly.LoadFrom("C:\Program Files\some.dll") t = asm.GetTypes() ty = asm.GetType(t(28).FullName) 'known class location m = ty.GetMethods() mm = ty.GetMethod("PerformLookup") Dim o as Object o = Activator.CreateInstance(ty) Dim oo as Object() retString = mm.Invoke(o,Nothing).ToString() Catch Ex As Exception End Try return retString End Function End Class

    Read the article

  • java - coding errors causing endless loop

    - by Daniel Key
    Im attempting to write a program that takes a population's birthrate and deathrate and loops the annual population until it either reaches 0 or doubles. My problem it that it continuously loops an endless amount of illegible numbers and i cant fix it. please help. //***************************************** //This program displays loop statements //Written by: Daniel Kellogg //Last Edited: 9/28/12 //**************************************** import java.util.Scanner; public class Hwk6 { public static void main (String[] args) { int currentYear, currentPopulation; double birthRate, deathRate; Scanner stdin = new Scanner(System.in); System.out.println("\nPopulation Estimator\n"); System.out.println("Enter Year"); currentYear = stdin.nextInt(); System.out.println("Enter Current Population"); currentPopulation = stdin.nextInt(); System.out.println("Enter Birthrate of Population"); birthRate = stdin.nextDouble(); System.out.println("Enter Deathrate of Population"); deathRate = stdin.nextDouble(); int counter = currentPopulation; System.out.println("Population: "); while (currentPopulation != -1) while (counter < currentPopulation * 2) { System.out.print(counter + " "); counter = counter + (int)(counter * birthRate - counter * deathRate); } System.exit(0); } }

    Read the article

  • SharePoint extensions for VS - which version have I got?

    - by Javaman59
    I'm using Visual Studio 2008, and have downloaded VSeWSS.exe 1.2, to enable Web Part development. I am new to SP development, and am already bewildered by the number of different versions of SP, and the VS add-ons. This particular problem has come up, which highlights my confusion. I selected Add - New Project - Visual C# - SharePoint- Web Part, accepted the defaults, and VS created a project, with the main file WebPart1.cs using System; using System.Runtime.InteropServices; using System.Web.UI; using System.Web.UI.WebControls; using System.Web.UI.WebControls.WebParts; using System.Xml.Serialization; using Microsoft.SharePoint; using Microsoft.SharePoint.WebControls; using Microsoft.SharePoint.WebPartPages; namespace WebPart1 { [Guid("9bd7e74c-280b-44d4-baa1-9271679657a0")] public class WebPart1 : System.Web.UI.WebControls.WebParts.WebPart { public WebPart1() { } protected override void CreateChildControls() // <-- This line { base.CreateChildControls(); // TODO: add custom rendering code here. // Label label = new Label(); // label.Text = "Hello World"; // this.Controls.Add(label); } } } The book I'm following, Essential SharePoint 2007, by Jeff Webb, has the following for the default project - using System; <...as previously> namespace WebPart1 { [Guid("9bd7e74c-280b-44d4-baa1-9271679657a0")] public class WebPart1 : System.Web.UI.WebControls.WebParts.WebPart { // ^ this is a new style (ASP.NET) web part! [author's comment] protected override void Render(HtmlTextWriter writer) // <-- This line { // This method draws the web part // TODO: add custom rendering code here. // Label label = new Label(); // writer.Write("Output HTML"); } } } The real reason for my concern is that in this chapter of the book the author frequently mentions the distinction between "old style" web parts, and "new style" web parts, as noted in his comment on the Render method. What's happened? Why has my default Web Part got a different signature to the authors?

    Read the article

  • InfoPath FormControl on STA worker thread

    - by Rob Ford
    I have a .NET class that exposes two public methods: one to create an InfoPath form and another to Export to one of the supported formats. I’m using the Microsoft FormControl to do this. It’s hosted by a Form that does not get displayed. I get called by a Winforms app, but on an MTA worker thread instead of the UI thread. So I create an STA thread and execute on that, which works exactly once and then results in this exception: System.InvalidOperationException was unhandled Message="Unable to get the window handle for the 'FormControl' control. Windowless ActiveX controls are not supported." Source="System.Windows.Forms" StackTrace: at System.Windows.Forms.AxHost.EnsureWindowPresent() at System.Windows.Forms.AxHost.InPlaceActivate() at System.Windows.Forms.AxHost.TransitionUpTo(Int32 state) at System.Windows.Forms.AxHost.CreateHandle() at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible) at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible) at System.Windows.Forms.AxHost.EndInit() at InfoPathCreateStaThreadTest.FormControlHost.InitializeComponent() in C:\Windows\Temp\InfoPathCreateStaThreadTest\InfoPathCreateStaThreadTest\FormControlHost.Designer.cs:line 65 After some experimenting, I started to suspect this is a message pumping problem. I then came across this, which makes me more strongly suspect so: http://blogs.msdn.com/cbrumme/archive/2004/02/02/66219.aspx I tried various methods of pumping messages with no luck. I should mention that the alternative of automating the InfoPath app is not viable unless I can figure out how to hide the app. Any help would be much appreciated.

    Read the article

  • multi-threaded proxy checker having problems

    - by Paul
    hello everyone, I am trying to create a proxy checker. This is my first attempt at multithreading and it's not going so well, the threads seem to be waiting for one to complete before initializing the next. Imports System.Net Imports System.IO Imports System.Threading Public Class Form1 Public sFileName As String Public srFileReader As System.IO.StreamReader Public sInputLine As String Public Class WebCall Public proxy As String Public htmlout As String Public Sub New(ByVal proxy As String) Me.proxy = proxy End Sub Public Event ThreadComplete(ByVal htmlout As String) Public Sub send() Dim myWebRequest As HttpWebRequest = CType(WebRequest.Create("http://www.myserver.com/ip.php"), HttpWebRequest) myWebRequest.Proxy = New WebProxy(proxy, False) Try Dim myWebResponse As HttpWebResponse = CType(myWebRequest.GetResponse(), HttpWebResponse) Dim loResponseStream As StreamReader = New StreamReader(myWebResponse.GetResponseStream()) htmlout = loResponseStream.ReadToEnd() Debug.WriteLine("Finished - " & htmlout) RaiseEvent ThreadComplete(htmlout) Catch ex As WebException If (ex.Status = WebExceptionStatus.ConnectFailure) Then End If Debug.WriteLine("Failed - " & proxy) End Try End Sub End Class Private Sub Button1_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button1.Click Dim proxy As String Dim webArray As New ArrayList() Dim n As Integer For n = 0 To 2 proxy = srFileReader.ReadLine() webArray.Add(New WebCall(proxy)) Next Dim w As WebCall For Each w In webArray Threading.ThreadPool.QueueUserWorkItem(New WaitCallback(AddressOf w.send), w) Next w End Sub Private Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load srFileReader = System.IO.File.OpenText("proxies.txt") End Sub End Class

    Read the article

  • Help decoupling Crystal Report from CrystalReportViewer

    - by John at CashCommons
    I'm using Visual Studio 2005 with VB.NET. I have a number of Crystal Reports, each with their own associated dialog resource containing a CrystalReportViewer. The class definitions look like this: Imports System.Windows.Forms Imports CrystalDecisions.CrystalReports.Engine Imports CrystalDecisions.Shared Public Class dlgForMyReport Private theReport As New myCrystalReport Public theItems As New List(Of MyItem) Private Sub OK_Button_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles OK_Button.Click Me.DialogResult = System.Windows.Forms.DialogResult.OK Me.Close() End Sub Private Sub Cancel_Button_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Cancel_Button.Click Me.DialogResult = System.Windows.Forms.DialogResult.Cancel Me.Close() End Sub Private Sub dlgForMyReport_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load theReport.SetDataSource(theItems) 'Do a bunch of stuff here to set data items in theReport Me.myCrystalReportViewer.ReportSource = theReport End Sub End Class I basically instantiate the dialog, set theItems to the list I want, and call ShowDialog. I now have a need to combine several of these reports into one report (possibly like this) but the code that loads up the fields in the report is in the dialog. How would I go about decoupling the report initialization from the dialog? Thanks!

    Read the article

  • How to change a Linux user password from python

    - by Vaulor
    I'm having problems with changing a Linux user's password from python. I've tried so many things, but I couldn't manage to solve the issue, here is the sample of things I've already tried: sudo_password is the password for sudo, sudo_command is the command I want the system to run, user is get from a List and is the user who I want to change the password for, and newpass is the pass I want to assign to 'user' user = list.get(ANCHOR) sudo_command = 'passwd' f = open("passwordusu.tmp", "w") f.write("%s\n%s" % (newpass, newpass)) f.close() A=os.system('echo -e %s|sudo -S %s < %s %s' % (sudo_password, sudo_command,'passwordusu.tmp', user)) print A windowpass.destroy() 'A' is the return value for the execution of os.system, in this case 256. I tried also A=os.system('echo %s|sudo -S %s < %s %s' % (sudo_password, sudo_command,'passwordusu.tmp', user)) but it returns the same error code. I tried several other ways with 'passwd' command, but whithout succes. With 'chpasswd' command I 've tried this: user = list.get(ANCHOR) sudo_command = 'chpasswd' f = open("passwordusu.tmp", "w") f.write("%s:%s" % (user, newpass)) f.close() A=os.system('echo %s|sudo -S %s < %s %s' % (sudo_password, sudo_command,'passwordusu.tmp', user)) print A windowpass.destroy() also with: A=os.system('echo %s|sudo -S %s:%s|%s' % (sudo_password, user, newpass, sudo_command)) @;which returns 32512 A=os.system("echo %s | sudo -S %s < \"%s\"" % (sudo_password, sudo_command, "passwordusu.tmp")) @;which returns 256 I tried 'mkpasswd' and 'usermod' too like this: user = list.get(ANCHOR) sudo_command = 'mkpasswd -m sha-512' os.system("echo %s | sudo -S %s %s > passwd.tmp" % (sudo_password,sudo_command, newpass)) sudo_command="usermod -p" f = open('passwd.tmp', 'r') for line in f.readlines(): newpassencryp=line f.close() A=os.system("echo %s | sudo -S %s %s %s" % (sudo_password, sudo_command, newpassencryp, user)) @;which returns 32512 but, if you go to https://www.mkpasswd.net , hash the 'newpass' and substitute for 'newpassencryp', it returns 0 which theoretically means it has gone right, but so far it doesn't changes the password. I've searched on internet and stackoverflow for this issue or similar and tried what solutions exposed, but again,without success. I would really apreciate any help, and of course, if you need more info i'll be glad to supply it! Thanks in advance.

    Read the article

  • Getting the data inside the C# web service from Jsonified string

    - by gnomixa
    In my JS I use Jquery's $ajax functions to call the web service and send the jsonified data to it. The data is in the following format: var countries = { "1A": { id: "1A", name: "Andorra" }, "2B": { id: 2B name: "Belgium" }, ..etc }; var jsonData = JSON.stringify({ data: data }); //then $ajax is called and it makes the call to the c# web service On the c# side the web service needs to unpack this data, currently it comes in as string[][] data type. How do I convert it to the format so I can refer to the properties such as .id and .name? Assuming I have a class called Sample with these properties? Thanks! EDIT: Here is my JS code: var jsonData = JSON.stringify(countries); $.ajax({ type: 'POST', url: 'http://localhost/MyService.asmx/Foo', contentType: 'application/json; charset=utf-8', data: jsonData, success: function (msg) { alert(msg.d); }, error: function (xhr, status) { switch (status) { case 404: alert('File not found'); break; case 500: alert('Server error'); break; case 0: alert('Request aborted'); break; default: alert('Unknown error ' + status); } } }); inside c# web service I have: using System; using System.Collections.Generic; using System.Linq; using System.Web; using System.Web.Services; using System.Data; using System.Collections; using System.IO; using System.Web.Script.Services; [WebMethod] [ScriptMethod] public string Foo(IDictionary<string, Country> countries) { return "success"; }

    Read the article

  • Sending Email over VPN SmtpException net_io_connectionclosed

    - by Holy Christ
    I am sending an email from a WPF application. When sending as a domain user on the network, the emails sends as expected. However, when I attempt to send email over a VPN connection, I get the following exception: Exception: System.Net.Mail.SmtpException: Failure sending mail. --- System.IO.IOException: Unable to read data from the transport connection: net_io_connectionclosed. at System.Net.Mail.SmtpReplyReaderFactory.ProcessRead(Byte[] buffer, Int32 offset, Int32 read, Boolean readLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLines(SmtpReplyReader caller, Boolean oneLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLine(SmtpReplyReader caller) at System.Net.Mail.SmtpConnection.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpTransport.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpClient.GetConnection() at System.Net.Mail.SmtpClient.Send(MailMessage message) I have tried using impersonation as well as setting the Credentials on the SmtpClient. Neither seem to work: using (new ImpersonateUser("myUser", "MYDOMAIN", "myPass")) { var client = new SmtpClient("myhost.com"); client.UseDefaultCredentials = true; client.Credentials = new NetworkCredential("myUser", "myPass", "MYDOMAIN"); client.Send(mailMessage); } I've also tried using Wireshark to view the message over the wire, but I don't know enough about SMTP to know what I'm looking for. One other variable is that the machine I'm using on the VPN is Vista Business and the machine on the network is Win7. I don't think it's related, but then I wouldn't be asking if I knew the issue! :) Any ideas?

    Read the article

  • Is a control's OnInit called even when attaching it during parent's OnPreRender?

    - by Xerion
    My original understanding was that the asp.net page lifecycle is run once for all pages and controls under normal circumstances. When I attached a control during a container's OnPreRender, I encountered a situation where the control's OnInit was not called. OK, I considered that a bug in my code and fixed as such, by attaching the control earlier. But just today, I encountered a situation where OnInit for a control seems to be called after the normal OnInit has been done for everyone else. See stack below. It seems that during the page's PreRender, the control's OnInit is called as it is being dynamically added. So I just want to confirm exactly what ASP.NET's behavior is? Does it actually keep track of the stage of each control's lifecycle, and upon adding a new control, it will run from the very beginning? [HttpException (0x80004005): The control collection cannot be modified during DataBind, Init, Load, PreRender or Unload phases.] System.Web.UI.ControlCollection.Add(Control child) +8678663 MyCompany.Web.Controls.SetStartPageWrapper.Initialize() MyCompany.Web.Controls.SetStartPageWrapper.OnInit(EventArgs e) System.Web.UI.Control.InitRecursive(Control namingContainer) +333 System.Web.UI.Control.InitRecursive(Control namingContainer) +210 System.Web.UI.Control.AddedControl(Control control, Int32 index) +198 System.Web.UI.ControlCollection.Add(Control child) +80 MyCompany.Web.Controls.PageHeader.OnPreRender(EventArgs e) in System.Web.UI.Control.PreRenderRecursiveInternal() +80 System.Web.UI.Control.PreRenderRecursiveInternal() +171 System.Web.UI.Control.PreRenderRecursiveInternal() +171 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +842

    Read the article

  • A generic error occurred in GDI+, JPEG Image to MemoryStream

    - by madcapnmckay
    Hi, This seems to be a bit of an infamous error all over the web. So much so that I have been unable to find an answer to my problem as my scenario doesn't fit. An exception gets thrown when I save the image to the stream. Weirdly this works perfectly with a png but gives the above error with jpg and gif which is rather confusing. Most similar problem out there relate to saving images to files without permissions. Ironically the solution is to use a memory stream as I am doing.... public static byte[] ConvertImageToByteArray(Image imageToConvert) { using (var ms = new MemoryStream()) { ImageFormat format; switch (imageToConvert.MimeType()) { case "image/png": format = ImageFormat.Png; break; case "image/gif": format = ImageFormat.Gif; break; default: format = ImageFormat.Jpeg; break; } imageToConvert.Save(ms, format); return ms.ToArray(); } } More detail to the exception. The reason this causes so many issues is the lack of explanation :( System.Runtime.InteropServices.ExternalException was unhandled by user code Message="A generic error occurred in GDI+." Source="System.Drawing" ErrorCode=-2147467259 StackTrace: at System.Drawing.Image.Save(Stream stream, ImageCodecInfo encoder, EncoderParameters encoderParams) at System.Drawing.Image.Save(Stream stream, ImageFormat format) at Caldoo.Infrastructure.PhotoEditor.ConvertImageToByteArray(Image imageToConvert) in C:\Users\Ian\SVN\Caldoo\Caldoo.Coordinator\PhotoEditor.cs:line 139 at Caldoo.Web.Controllers.PictureController.Croppable() in C:\Users\Ian\SVN\Caldoo\Caldoo.Web\Controllers\PictureController.cs:line 132 at lambda_method(ExecutionScope , ControllerBase , Object[] ) at System.Web.Mvc.ActionMethodDispatcher.Execute(ControllerBase controller, Object[] parameters) at System.Web.Mvc.ReflectedActionDescriptor.Execute(ControllerContext controllerContext, IDictionary`2 parameters) at System.Web.Mvc.ControllerActionInvoker.InvokeActionMethod(ControllerContext controllerContext, ActionDescriptor actionDescriptor, IDictionary`2 parameters) at System.Web.Mvc.ControllerActionInvoker.<>c__DisplayClassa.<InvokeActionMethodWithFilters>b__7() at System.Web.Mvc.ControllerActionInvoker.InvokeActionMethodFilter(IActionFilter filter, ActionExecutingContext preContext, Func`1 continuation) InnerException: OK things I have tried so far. Cloning the image and working on that. Retrieving the encoder for that MIME passing that with jpeg quality setting. Please can anyone help.

    Read the article

  • Visual Studio 2008 Installer, Custom Action. Breakpoint not firing.

    - by Snake
    Hi, I've got an installer with a custom action project. I want the action to fire at install. The action fires, when I write something to the event log, it works perfectly. But I really need to debug the file since the action is quite complicated. So I've got the following installer class: namespace InstallerActions { using System; using System.Collections; using System.Collections.Generic; using System.ComponentModel; using System.Configuration.Install; using System.Diagnostics; using System.IO; [RunInstaller(true)] // ReSharper disable UnusedMember.Global public partial class DatabaseInstallerAction : Installer // ReSharper restore UnusedMember.Global { public DatabaseInstallerAction() { InitializeComponent(); } public override void Install(IDictionary stateSaver) { base.Install(stateSaver); System.Diagnostics.Debugger.Launch(); System.Diagnostics.Debugger.Break(); // none of these work Foo(); } private static void Foo() { } } } The installer just finalizes without warning me, it doesn't break, it doesn't ask me to attach a debugger. I've tried debug and release mode. Am I missing something? Thanks -Snake

    Read the article

  • Preselection in the save dialog (c#)

    - by FullmetalBoy
    Goal: Save a notepad file in the computer. (C#) Problem: I don't know how to make a preselection as "TXT Files(*.txt)" in the "Save as type:" when save dialog display? // Fullmetalboy using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.IO; namespace Labb2_application { public partial class MainForm : Form { public MainForm() { InitializeComponent(); } private void mnuFileOpen_Click(object sender, EventArgs e) { OpenFileDialog fDialog = new OpenFileDialog(); fDialog.Title = "Öppna"; fDialog.Filter = "Text files|*.txt"; fDialog.InitialDirectory = @"C:\Windows"; fDialog.ShowHelp = true; DialogResult result = fDialog.ShowDialog(); // Show the dialog and get result. if (result == DialogResult.OK) { string fileAdress = fDialog.FileName; try { string textContent = File.ReadAllText(fileAdress); rtxtDisplay.Text = textContent; } catch (IOException) { } } // If syntax } private void mnuFileSave_Click(object sender, EventArgs e) { saveAsFileDialog.ShowDialog(); } private void mnuFileSaveAs_Click(object sender, EventArgs e) { saveAsFileDialog.Filter = "Text files|*.txt"; saveAsFileDialog.ShowDialog(); } private void mnuFileExit_Click(object sender, EventArgs e) { Application.Exit(); } private void saveAsFileDialog_FileOk(object sender, CancelEventArgs e) { string fileNameAddress = saveAsFileDialog.FileName; File.WriteAllText(fileNameAddress, rtxtDisplay.Text); } } // Partial Class }

    Read the article

  • Use of RegularExpressionValidator in MS .Net Framework

    - by Lawk Salih
    Hi- I am trying to use the RegularExpressionValidator Control in Visual Studio to validate a textbox for email address expressions. Here's my code (very basic) Email:&nbsp; <input id="Text1" type="text" /><br /> <br /> <input id="Validate" type="button" value="Validate" runat="server" /><br /> <br /> <asp:RegularExpressionValidator ID="RegularExpressionValidator1" runat="server" ErrorMessage="RegularExpressionValidator" ControlToValidate="Validate" ValidationExpression="\w+([-+.']\w+)*@\w+([-.]\w+)*\.\w+([-.]\w+)*"></asp:RegularExpressionValidator> Now, when I set controlToValidate to Validate, I get the following error message: Server Error in '/' Application. Control 'Validate' referenced by the ControlToValidate property of 'RegularExpressionValidator1' cannot be validated. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Web.HttpException: Control 'Validate' referenced by the ControlToValidate property of 'RegularExpressionValidator1' cannot be validated. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [HttpException (0x80004005): Control 'Validate' referenced by the ControlToValidate property of 'RegularExpressionValidator1' cannot be validated.] System.Web.UI.WebControls.BaseValidator.CheckControlValidationProperty(String name, String propertyName) +8734357 System.Web.UI.WebControls.BaseValidator.ControlPropertiesValid() +40 System.Web.UI.WebControls.BaseValidator.get_PropertiesValid() +21 System.Web.UI.WebControls.BaseValidator.OnPreRender(EventArgs e) +27 System.Web.UI.Control.PreRenderRecursiveInternal() +80 System.Web.UI.Control.PreRenderRecursiveInternal() +171 System.Web.UI.Control.PreRenderRecursiveInternal() +171 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +842 Version Information: Microsoft .NET Framework Version:2.0.50727.3607; ASP.NET Version:2.0.50727.3082 I have tried the same mechanism before and have worked; however, this time I am on a new machine, WinXP Pro running IIS v5.1. Any direction would be appreciated.

    Read the article

  • calculating the index of an array C#

    - by Kerry G
    I want to display a list of the answers a student entered incorrectly. How do I identify the index of these questions? I am hoping to change the contents of a textbox to a list of the questions answered incorrectly, which would require calculating the index of each incorrect question. using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Threading.Tasks; using System.Windows.Forms; namespace WindowsFormsApplication5 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } //return a pass/fail //return number of correct answers //return number of incorrect answers //return index figures of incorrect values public void examResults () { string[] correctAnswers = {B,D,A,A,C,A,B,A,C,D,B,C,D,A,D,C,C,B,D,A}; string[] studentResults = File.ReadAllLines("studentResults.txt"); var c = correctAnswers.Where((x, i) => x.Equals(studentResults[i])).Count(); if ( c <= 14) passFailBox.Text = "Student has failed the exam"; else passFailBox.Text = "Student has passed the exam"; numberCorrectBox.Text = "Student has answered" + c + "answers correctly"; int f; f= 21-c; numberIncorrectBox.Text = "Student has answered" + f + "answers incorrectly"; } } }

    Read the article

  • Load Testing Java Web Application - find TPS / Avg transaction response time

    - by Steve
    I would like to build my own load testing tool in Java with the goal of being able to load test a web application I am building throughout the development cycle. The web application will be receiving server to server HTTP Post requests and I would like to find its starting transaction per second (TPS) capacity along with the avgerage response time. The Post request and response messages will be in XML (I dont' think that's really applicable though :) ). I have written a very simple Java app to send transactions and count how many transactions it was able to send in one second (1000 ms) however I don't think this is the best way to load test. Really what I want is to send any number of transactions at exactly the same time - i.e. 10, 50, 100 etc. Any help would be appreciated! Oh and here is my current test app code: Thread[] t = new Thread[1]; for (int a = 0; a < t.length; a++) { t[a] = new Thread(new MessageLoop()); } startTime = System.currentTimeMillis(); System.out.println(startTime); for (int a = 0; a < t.length; a++) { t[a].start(); } while ((System.currentTimeMillis() - startTime) < 1000 ) { } if ((System.currentTimeMillis() - startTime) > 1000 ) { for (int a = 0; a < t.length; a++) { t[a].interrupt(); } } long endTime = System.currentTimeMillis(); System.out.println(endTime); System.out.println("Total time: " + (endTime - startTime)); System.out.println("Total transactions: " + count); private static class MessageLoop implements Runnable { public void run() { try { //Test Number of transactions while ((System.currentTimeMillis() - startTime) < 1000 ) { // SEND TRANSACTION HERE count++; } } catch (Exception e) { } } }

    Read the article

  • How to find a function of application with ollydbg?

    - by user3725506
    Let's say i released the application below. using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Threading.Tasks; using System.Windows.Forms; namespace WindowsFormsApplication2 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void button1_Click(object sender, EventArgs e) { MessageBox.Show("Hello World!","Message Box"); } } } Now here is my questions: How to find the function of button which is responsible to show message box after pressing the button with ollydbg? How to disable the button click ? Notes:this must be done with ollydbg only. Assume that i don't have access to the code. A step-by-step example would be greatly appreciated.

    Read the article

  • How to fix “The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated.”

    - by ybbest
    Problem: When I try to publish a SharePoint2013 workflow, I received the error: The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated. After that, my workflow stopped working and every time I start a work I receive the following error message: System.ApplicationException: PreconditionFailed ---> System.ApplicationException: Error in the application. --- End of inner exception stack trace --- at System.Activities.Statements.Throw.Execute(CodeActivityContext context) at System.Activities.CodeActivity.InternalExecute(ActivityInstance instance, ActivityExecutor executor, BookmarkManager bookmarkManager) at System.Activities.Runtime.ActivityExecutor.ExecuteActivityWorkItem.ExecuteBody(ActivityExecutor executor, BookmarkManager bookmarkManager, Location resultLocation) Analysis: After analysis, I found the error by visiting the http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc and the error I got on the message is                                                                                                                                              Solution: The solution is basically getting more memory to the server. For development environment, you can restart your noderunner.exe or some other services to release some memories. To verify you have enough memory    you can browse to http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc , it should return the information below. Then you can republish your workflow and it will work like a charm.

    Read the article

  • How to fix “The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated.”

    - by ybbest
    Problem: When I try to publish a SharePoint2013 workflow, I received the error: The requested service, ‘net.pipe://localhost/SecurityTokenServiceApplication/appsts.svc’ could not be activated. After that, my workflow stopped working and every time I start a work I receive the following error message: System.ApplicationException: PreconditionFailed ---> System.ApplicationException: Error in the application. --- End of inner exception stack trace --- at System.Activities.Statements.Throw.Execute(CodeActivityContext context) at System.Activities.CodeActivity.InternalExecute(ActivityInstance instance, ActivityExecutor executor, BookmarkManager bookmarkManager) at System.Activities.Runtime.ActivityExecutor.ExecuteActivityWorkItem.ExecuteBody(ActivityExecutor executor, BookmarkManager bookmarkManager, Location resultLocation) Analysis: After analysis, I found the error by visiting the http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc and the error I got on the message is                                                                                                                                              Solution: The solution is basically getting more memory to the server. For development environment, you can restart your noderunner.exe or some other services to release some memories. To verify you have enough memory    you can browse to http://localhost:32843/SecurityTokenServiceApplication/securitytoken.svc , it should return the information below. Then you can republish your workflow and it will work like a charm.

    Read the article

  • Windows Azure Use Case: Agility

    - by BuckWoody
    This is one in a series of posts on when and where to use a distributed architecture design in your organization's computing needs. You can find the main post here: http://blogs.msdn.com/b/buckwoody/archive/2011/01/18/windows-azure-and-sql-azure-use-cases.aspx  Description: Agility in this context is defined as the ability to quickly develop and deploy an application. In theory, the speed at which your organization can develop and deploy an application on available hardware is identical to what you could deploy in a distributed environment. But in practice, this is not always the case. Having an option to use a distributed environment can be much faster for the deployment and even the development process. Implementation: When an organization designs code, they are essentially becoming a Software-as-a-Service (SaaS) provider to their own organization. To do that, the IT operations team becomes the Infrastructure-as-a-Service (IaaS) to the development teams. From there, the software is developed and deployed using an Application Lifecycle Management (ALM) process. A simplified view of an ALM process is as follows: Requirements Analysis Design and Development Implementation Testing Deployment to Production Maintenance In an on-premise environment, this often equates to the following process map: Requirements Business requirements formed by Business Analysts, Developers and Data Professionals. Analysis Feasibility studies, including physical plant, security, manpower and other resources. Request is placed on the work task list if approved. Design and Development Code written according to organization’s chosen methodology, either on-premise or to multiple development teams on and off premise. Implementation Code checked into main branch. Code forked as needed. Testing Code deployed to on-premise Testing servers. If no server capacity available, more resources procured through standard budgeting and ordering processes. Manual and automated functional, load, security, etc. performed. Deployment to Production Server team involved to select platform and environments with available capacity. If no server capacity available, standard budgeting and procurement process followed. If no server capacity available, systems built, configured and put under standard organizational IT control. Systems configured for proper operating systems, patches, security and virus scans. System maintenance, HA/DR, backups and recovery plans configured and put into place. Maintenance Code changes evaluated and altered according to need. In a distributed computing environment like Windows Azure, the process maps a bit differently: Requirements Business requirements formed by Business Analysts, Developers and Data Professionals. Analysis Feasibility studies, including budget, security, manpower and other resources. Request is placed on the work task list if approved. Design and Development Code written according to organization’s chosen methodology, either on-premise or to multiple development teams on and off premise. Implementation Code checked into main branch. Code forked as needed. Testing Code deployed to Azure. Manual and automated functional, load, security, etc. performed. Deployment to Production Code deployed to Azure. Point in time backup and recovery plans configured and put into place.(HA/DR and automated backups already present in Azure fabric) Maintenance Code changes evaluated and altered according to need. This means that several steps can be removed or expedited. It also means that the business function requesting the application can be held directly responsible for the funding of that request, speeding the process further since the IT budgeting process may not be involved in the Azure scenario. An additional benefit is the “Azure Marketplace”, In effect this becomes an app store for Enterprises to select pre-defined code and data applications to mesh or bolt-in to their current code, possibly saving development time. Resources: Whitepaper download- What is ALM?  http://go.microsoft.com/?linkid=9743693  Whitepaper download - ALM and Business Strategy: http://go.microsoft.com/?linkid=9743690  LiveMeeting Recording on ALM and Windows Azure (registration required, but free): http://www.microsoft.com/uk/msdn/visualstudio/contact-us.aspx?sbj=Developing with Windows Azure (ALM perspective) - 10:00-11:00 - 19th Jan 2011

    Read the article

  • DLL-s needed to run ASP.NET MVC 3 RC on Windows Azure

    - by DigiMortal
    In this weekend I made one of my new apps run on Windows Azure. I am building this application using ASP.NET MVC 3 RC and Razor view engine. In this posting I will list DLL-s you need to have as local copies to get ASP.NET MVC 3 RC run on Windows Azure web role. Besides assemblies that are already references you may need to add references to some more assemblies. List of assemblies is here: Microsoft.Web.Infrastructure System.Web.Helpers System.Web.Mvc System.Web.Razor System.Web.WebPages System.Web.WebPages.Razor WebMatrix.Data You can find Razor and ASP.NET Web Pages related assemblies from folder: C:\Program Files\Microsoft ASP.NET\ASP.NET Web Pages\v1.0\Assemblies\ NB! If your project is using dynamically loaded assemblies that are not referenced from any of your project make sure you are including them as project items that are located in bin folder. This way these DLL-s are also put to deployment package and you don’t have to create code level references to them.

    Read the article

  • How to manage security cameras in Ubuntu?

    - by Josh
    I am setting up a server of sorts and chose ubuntu for the OS as my dad has it on a few computers. I am unimpressed with Windows or MAC due to all the add-ons and complexity of it when all I want is something simple. The system will have 3 purposes, storing my wife's photography work (she is a professional photographer) storing music for quick access to our entertainment system (will be running the system through the tv in our living room and thus through our surround sound) and will also serve as a DVR unit for a home security system I am going to put together. My question is what sort of software options are there for the Ubuntu system as far as a DVR with frame by frame playback. It does not need to be fancy but of course a variety of options are a nice touch.

    Read the article

  • Oracle Linux 6 Implementation Essentials Certification Exam Now Available

    - by Antoinette O'Sullivan
    Get proof of your linux system administration skills by taking the Oracle Linux 6 Implementation Essentials Certification exam. This certification is available to all candidates. Oracle Partner Members earning this certification will be recognized as OPN Certified Specialists. This certification takes under 3 hours, asking you between 120-150 questions on areas including: Introduction to Oracle Linux Installing Oracle Linux 6 Linux Boot Process Oracle Linux System Configuration and Process Management Oracle Linux Package Management Ksplice Zero Downtime Updates Automate Tasks and System Logging User and Group Administration Oracle Linux File Sytems and Storage Administration Network Administration Oracle Linux System Monitoring and Troubleshooting Oracle Certifications are among the most sought after badges of credibility for expertise in the Information Technology marketplace. See Benefits of Oracle Certification for more information. To prepare for this exam, you can take the Oracle Linux System Administration training.

    Read the article

  • Windows 7 doesn't boot after Ubuntu install

    - by Omu
    I had windows 7 installed on my pc, then I installed Ubuntu 10.10/ During the installation process I have chosen to manually set my partitions: I set a 10GB drive for ubuntu root 1GB drive for swap and for boot drive I've chosen the one used by windows 7 Now I can boot ubuntu, I have the windows 7 option in the boot list, but when I choose Windows 7, it shows me a black screen for a second and returns back to boot screen. Boot Info Script 0.55 dated February 15th, 2010 ============================= Boot Info Summary: ============================== = Windows is installed in the MBR of /dev/sda sda1: _________________________________________________________________________ File system: ntfs Boot sector type: Grub 2 Boot sector info: Grub 2 is installed in the boot sector of sda1 and looks at sector 304908237 of the same hard drive for core.img, but core.img can not be found at this location. No errors found in the Boot Parameter Block. Operating System: Windows 7 Boot files/dirs: /bootmgr /Boot/BCD /Windows/System32/winload.exe sda2: _________________________________________________________________________ File system: ntfs Boot sector type: Windows XP Boot sector info: No errors found in the Boot Parameter Block. Operating System: Boot files/dirs: sda3: _________________________________________________________________________ File system: Extended Partition Boot sector type: - Boot sector info: sda5: _________________________________________________________________________ File system: ext4 Boot sector type: - Boot sector info: Operating System: Ubuntu 10.10 Boot files/dirs: /boot/grub/grub.cfg /etc/fstab /boot/grub/core.img sda4: _________________________________________________________________________ File system: swap Boot sector type: - Boot sector info: =========================== Drive/Partition Info: ============================= Drive: sda ___________________ _____________________________________________________ Disk /dev/sda: 160.0 GB, 160041885696 bytes 255 heads, 63 sectors/track, 19457 cylinders, total 312581808 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes Partition Boot Start End Size Id System /dev/sda1 * 63 62,894,474 62,894,412 7 HPFS/NTFS /dev/sda2 62,894,478 291,579,749 228,685,272 7 HPFS/NTFS /dev/sda3 291,579,811 309,157,937 17,578,127 5 Extended /dev/sda5 291,579,813 309,157,937 17,578,125 83 Linux /dev/sda4 309,159,936 312,580,095 3,420,160 82 Linux swap / Solaris blkid -c /dev/null: ____________________________________________________________ Device UUID TYPE LABEL /dev/sda1 1266BB2766BB0A8D ntfs /dev/sda2 BEDBF1147C76F703 ntfs DATA /dev/sda3: PTTYPE="dos" /dev/sda4 dd38226d-c7c9-4ae5-a726-6d18d34a22e4 swap /dev/sda5 e1dafd1c-f855-406b-8f9a-f9d527c70255 ext4 /dev/sda: PTTYPE="dos" ============================ "mount | grep ^/dev output: =========================== Device Mount_Point Type Options /dev/sda5 / ext4 (rw,errors=remount-ro,commit=0) =========================== sda5/boot/grub/grub.cfg: =========================== # # DO NOT EDIT THIS FILE # # It is automatically generated by grub-mkconfig using templates # from /etc/grub.d and settings from /etc/default/grub # ### BEGIN /etc/grub.d/00_header ### if [ -s $prefix/grubenv ]; then set have_grubenv=true load_env fi set default="0" if [ "${prev_saved_entry}" ]; then set saved_entry="${prev_saved_entry}" save_env saved_entry set prev_saved_entry= save_env prev_saved_entry set boot_once=true fi function savedefault { if [ -z "${boot_once}" ]; then saved_entry="${chosen}" save_env saved_entry fi } function recordfail { set recordfail=1 if [ -n "${have_grubenv}" ]; then if [ -z "${boot_once}" ]; then save_env recordfail; fi; fi } function load_video { insmod vbe insmod vga } insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 if loadfont /usr/share/grub/unicode.pf2 ; then set gfxmode=640x480 load_video insmod gfxterm fi terminal_output gfxterm insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 set locale_dir=($root)/boot/grub/locale set lang=en insmod gettext if [ "${recordfail}" = 1 ]; then set timeout=-1 else set timeout=10 fi ### END /etc/grub.d/00_header ### ### BEGIN /etc/grub.d/05_debian_theme ### set menu_color_normal=white/black set menu_color_highlight=black/light-gray ### END /etc/grub.d/05_debian_theme ### ### BEGIN /etc/grub.d/10_linux ### menuentry 'Ubuntu, with Linux 2.6.35-22-generic' --class ubuntu --class gnu-linux --class gnu --class os { recordfail insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 linux /boot/vmlinuz-2.6.35-22-generic root=UUID=e1dafd1c-f855-406b-8f9a-f9d527c70255 ro quiet splash initrd /boot/initrd.img-2.6.35-22-generic } menuentry 'Ubuntu, with Linux 2.6.35-22-generic (recovery mode)' --class ubuntu --class gnu-linux --class gnu --class os { recordfail insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 echo 'Loading Linux 2.6.35-22-generic ...' linux /boot/vmlinuz-2.6.35-22-generic root=UUID=e1dafd1c-f855-406b-8f9a-f9d527c70255 ro single echo 'Loading initial ramdisk ...' initrd /boot/initrd.img-2.6.35-22-generic } ### END /etc/grub.d/10_linux ### ### BEGIN /etc/grub.d/20_linux_xen ### ### END /etc/grub.d/20_linux_xen ### ### BEGIN /etc/grub.d/20_memtest86+ ### menuentry "Memory test (memtest86+)" { insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 linux16 /boot/memtest86+.bin } menuentry "Memory test (memtest86+, serial console 115200)" { insmod part_msdos insmod ext2 set root='(hd0,msdos5)' search --no-floppy --fs-uuid --set e1dafd1c-f855-406b-8f9a-f9d527c70255 linux16 /boot/memtest86+.bin console=ttyS0,115200n8 } ### END /etc/grub.d/20_memtest86+ ### ### BEGIN /etc/grub.d/30_os-prober ### menuentry "Windows 7 (loader) (on /dev/sda1)" { insmod part_msdos insmod ntfs set root='(hd0,msdos1)' search --no-floppy --fs-uuid --set 1266bb2766bb0a8d chainloader +1 } ### END /etc/grub.d/30_os-prober ### ### BEGIN /etc/grub.d/40_custom ### # This file provides an easy way to add custom menu entries. Simply type the # menu entries you want to add after this comment. Be careful not to change # the 'exec tail' line above. ### END /etc/grub.d/40_custom ### ### BEGIN /etc/grub.d/41_custom ### if [ -f $prefix/custom.cfg ]; then source $prefix/custom.cfg; fi ### END /etc/grub.d/41_custom ### =============================== sda5/etc/fstab: =============================== # /etc/fstab: static file system information. # # Use 'blkid -o value -s UUID' to print the universally unique identifier # for a device; this may be used with UUID= as a more robust way to name # devices that works even if disks are added and removed. See fstab(5). # # proc /proc proc nodev,noexec,nosuid 0 0 /dev/sda5 / ext4 errors=remount-ro 0 1 # swap was on /dev/sda4 during installation UUID=dd38226d-c7c9-4ae5-a726-6d18d34a22e4 none swap sw 0 0 =================== sda5: Location of files loaded by Grub: =================== 156.1GB: boot/grub/core.img 156.3GB: boot/grub/grub.cfg 149.9GB: boot/initrd.img-2.6.35-22-generic 156.3GB: boot/vmlinuz-2.6.35-22-generic 149.9GB: initrd.img 156.3GB: vmlinuz

    Read the article

  • Software Architecture verses Software Design

    Recently, I was asked what the differences between software architecture and software design are. At a very superficial level both architecture and design seem to mean relatively the same thing. However, if we examine both of these terms further we will find that they are in fact very different due to the level of details they encompass. Software Architecture can be defined as the essence of an application because it deals with high level concepts that do not include any details as to how they will be implemented. To me this gives stakeholders a view of a system or application as if someone was viewing the earth from outer space. At this distance only very basic elements of the earth can be detected like land, weather and water. As the viewer comes closer to earth the details in this view start to become more defined. Details about the earth’s surface will start to actually take form as well as mane made structures will be detected. The process of transitioning a view from outer space to inside our earth’s atmosphere is similar to how an architectural concept is transformed to an architectural design. From this vantage point stakeholders can start to see buildings and other structures as if they were looking out of a small plane window. This distance is still high enough to see a large area of the earth’s surface while still being able to see some details about the surface. This viewing point is very similar to the actual design process of an application in that it takes the very high level architectural concept or concepts and applies concrete design details to form a software design that encompasses the actual implementation details in the form of responsibilities and functions. Examples of these details include: interfaces, components, data, and connections. In review, software architecture deals with high level concepts without regard to any implementation details. Software design on the other hand takes high level concepts and applies concrete details so that software can be implemented. As part of the transition between software architecture to the creation of software design an evaluation on the architecture is recommended. There are several benefits to including this step as part of the transition process. It allows for projects to ensure that they are on the correct path as to meeting the stakeholder’s requirement goals, identifies possible cost savings and can be used to find missing or nonspecific requirements that cause ambiguity in a design. In the book “Evaluating Software Architectures: Methods and Case Studies”, they define key benefits to adding an architectural review process to ensure that an architecture is ready to move on to the design phase. Benefits to evaluating software architecture: Gathers all stakeholders to communicate about the project Goals are clearly defined in regards to the creation or validation of specific requirements Goals are prioritized so that when conflicts occur decisions will be made based on goal priority Defines a clear expectation of the architecture so that all stakeholders have a keen understanding of the project Ensures high quality documentation of the architecture Enables discoveries of architectural reuse  Increases the quality of architecture practices. I can remember a few projects that I worked on that could have really used an architectural review prior to being passed on to developers. This project was to create some new advertising space on the company’s website in order to sell space based on the location and some other criteria. I was one of the developer selected to lead this project and I was given a high level design concept and a long list of ever changing requirements due to the fact that sales department had no clear direction as to what exactly the project was going to do or how they were going to bill the clients once they actually agreed to purchase the Ad space. In my personal opinion IT should have pushed back to have the requirements further articulated instead of forcing programmers to code blindly attempting to build such an ambiguous project.  Unfortunately, we had to suffer with this project for about 4 months when it should have only taken 1.5 to complete due to the constantly changing and unclear requirements. References  Clements, P., Kazman, R., & Klein, M. (2002). Evaluating Software Architectures. Westford, Massachusetts: Courier Westford. 

    Read the article

< Previous Page | 252 253 254 255 256 257 258 259 260 261 262 263  | Next Page >