  • Spring-mvc project can't select from a particular mysql table

    - by Dan Ray
    I'm building a Spring-mvc project (using JPA and Hibernate for DB access) that is running just great locally, on my dev box, with a local MySQL database. Now I'm trying to put a snapshot up on a staging server for my client to play with, and I'm having trouble. Tomcat (after some wrestling) deploys my war file without complaint, and I can get some response from the application over the browser. When I hit my main page, which is behind Spring Security authentication, it redirects me to the login page, which works perfectly. I have Security configured to query the database for user details, and that works fine. In fact, a change to a password in the database is reflected in the behavior of the login form, so I'm confident it IS reaching the database and querying the user table. Once authenticated, we go to the first "real" page of the app, and I get a "data access failure" error. The server's console log gets this line (redacted): ERROR org.hibernate.util.JDBCExceptionReporter - SELECT command denied to user 'myDbUser'@'localhost' for table 'asset' However, if I go to MySQL from the shell using exactly the same creds, I have no problem at all selecting from the asset table: [development@tomcat01stg]$ mysql -u myDbUser -pmyDbPwd dbName ... mysql> \s -------------- mysql Ver 14.12 Distrib 5.0.77, for redhat-linux-gnu (i686) using readline 5.1 Connection id: 199 Current database: dbName Current user: myDbUser@localhost ... UNIX socket: /var/lib/mysql/mysql.sock -------------- mysql> select count(*) from asset; +----------+ | count(*) | +----------+ | 19 | +----------+ 1 row in set (0.00 sec) I've broken down my MySQL access settings, cleaned out the user and re-run the grant commands, set up a version of the user from 'localhost' and another from '%', making sure to flush permissions.... Nothing is changing the behavior of this thing. What gives?

    Read the article

  • How to set up RAID-0 first time on new PC?

    - by jasondavis
    I have built basic PC's in the past but have never used a RAID array at all. SO now I am buying parts to build my new PC, it will be an intel i7 processor. My motherboard will have RAID support which I will use instead of an aftermarket raid controller for now. Also I plan to use 2 SSD drives in RAID-0 for my windows 7 OS. (Please note that I am aware of the issues with doing this, including lack of TRIM support when using RAID with SSD drives. I am OK with it not working as I can just re[place the drives in a year or so or wheneer they become more sluggish). SO here is my question part. If I assemble the motherboard, PSU, processor, RAM, vidm card, etc and then go to turn the PC on, it will have the 2 SSD drives hooked up. so I assume I will then soon the BIOS screen before I install windows? How to I go about making the 2 drives work in RAID-0 at this point? I do the raid part before installing my OS right? Please help with the steps involved from assembling the parts of the PC and then turning it on, to the part of getting the RAID-0 set up between the 2 drives and then installing my windows 7 OS from a Optical drive? Please help, all advice, instructions, tips appreciated as long as on topic. I do not need to be told that this is a bad idea as far as if 1 drive fails I losse it all, I plan on having a disk IMAGE to be able to restore my OS and software to a new set of drives at anytime needed in the event of drive failure. Same goes for lack of TRIM support. Thanks for reading and help =)

    Read the article

  • Identifying Service Error in Fedora 16

    - by Cerin
    How do you find the cause of a failed service start in Fedora 16? The new systemctl command in Fedora 16 seems to horribly obscure any useful logging info. [root@host ~]# systemctl start httpd.service Job failed. See system logs and 'systemctl status' for details. [root@host ~]# systemctl status httpd.service httpd.service - The Apache HTTP Server (prefork MPM) Loaded: loaded (/lib/systemd/system/httpd.service; enabled) Active: failed since Thu, 21 Jun 2012 16:26:56 -0400; 1min 23s ago Process: 2119 ExecStop=/usr/sbin/httpd $OPTIONS -k stop (code=exited, status=0/SUCCESS) Process: 2215 ExecStart=/usr/sbin/httpd $OPTIONS -k start (code=exited, status=1/FAILURE) Main PID: 1062 (code=exited, status=0/SUCCESS) CGroup: name=systemd:/system/httpd.service So the first command fails...and it tells me to run another command...which simply tells me that the command returned an error code. Where's the actual error? Even more frustrating is nothing seems to have been written to the logs: [root@host ~]# ls -lah /var/log/httpd/ total 8.0K drwx------. 2 root root 4.0K Jun 21 16:19 . drwxr-xr-x. 21 root root 4.0K Jun 20 16:33 .. -rw-r----- 1 root root 0 Jun 21 16:19 modsec_audit.log -rw-r----- 1 root root 0 Jun 21 16:19 modsec_debug.log

    Read the article

  • Is execution of sync(8) still required before shutting down linux?

    - by Amos Shapira
    I still see people recommend use of "sync; sync; sync; sleep 30; halt" incantations when talking about shutting down or rebooting Linux. I've been running Linux since its inception and although this was the recommended procedure in the BSD 4.2/4.3 and SunOS 4 days, I can't recall that I had to do that for at least the last ten years, during which I probably went through shutdown/reboot of Linux maybe thousands of times. I suspect that this is an anachronism since the days that the kernel couldn't unmount and sync the root filesystem and other critical filesystems required even during single-user mode (e.g. /tmp), and therefore it was necessary to tell it explicitly to flush as much data as it can to disk. These days, without finding the relevant code in the kernel source yet (digging through http://lxr.linux.no and google), I suspect that the kernel is smart enough to cleanly unmount even the root filesystem and the filesystem is smart enough to effectively do a sync(2) before unmounting itself during a normal "shutdown"/"reboot"/"poweorff". The "sync; sync; sync" is only necessary in extreme cases where the filesystem won't unmount cleanly (e.g. physical disk failure) or the system is in a state that only forcing a direct reboot(8) will get it out of its freeze (e.g. the load is too high to let it schedule the shutdown command). I also never do the "sync" procedure before unmounting removable devices, and never hit a problem. Another example - Xen allows the DomU to be sent a "shutdown" command from the Dom0, this is considered a "clean shutdown" without anyone having to login and type the magical "sync; sync; sync" first. Am I right or was I lucky for a few thousands of system shutdowns?

    Read the article

  • Should I use "Raid 5 + spare" or "Raid 6"?

    - by Trevor Boyd Smith
    What is "Raid 5 + Spare" (excerpt from User Manual, Sect 4.17.2, P.54): RAID5+Spare: RAID 5+Spare is a RAID 5 array in which one disk is used as spare to rebuild the system as soon as a disk fails (Fig. 79). At least four disks are required. If one physical disk fails, the data remains available because it is read from the parity blocks. Data from a failed disk is rebuilt onto the hot spare disk. When a failed disk is replaced, the replacement becomes the new hot spare. No data is lost in the case of a single disk failure, but if a second disk fails before the system can rebuild data to the hot spare, all data in the array will be lost. What is "Raid 6" (excerpt from User Manual, Sect 4.17.2, P.54): RAID6: In RAID 6, data is striped across all disks (minimum of four) and a two parity blocks for each data block (p and q in Fig. 80) is written on the same stripe. If one physical disk fails, the data from the failed disk can be rebuilt onto a replacement disk. This Raid mode can support up to two disk failures with no data loss. RAID 6 provides for faster rebuilding of data from a failed disk. Both "Raid 5 + spare" and "Raid 6" are SO similar ... I can't tell the difference. When would "Raid 5 + Spare" be optimal? And when would "Raid 6" be optimal"? The manual dumbs down the different raid with 5 star ratings. "Raid 5 + Spare" only gets 4 stars but "Raid 6" gets 5 stars. If I were to blindly trust the manual I would conclude that "Raid 6" is always better. Is "Raid 6" always better?

    Read the article

  • Intermittent extrememly long response times when downloading documents

    - by pap
    I have a Java web application running om Tomcat 7 with an Apache httpd 2.2 fronting with mod_jk/AJP. One part of the application is serving files (up to 4mb size). Now, normally this all runs very smooth with stable, low response-times. However, in rare instances (<0.1% of downloads), the downloadtime will go beyond 1 minute. After activating the ThreadStuckValve in Tomcat, I can see that the long responses seem to be stuck at org.apache.tomcat.jni.Socket.sendbb(Native method) i.e network I/O. At most, these long-running downloads take 5 minutes, which I strongly suspect is because of the default 300 second timout in Apache 2.2 (http://httpd.apache.org/docs/2.2/mod/core.html, "TimeOut directive"). To me, this looks like network problems. The Apache timeout (if that is what is kicking in at the 5 minute mark) indicates that ACK packets are not being transmitted correctly. My questions are what could be causing this? Closed browser at receiving end but socket not signaled as closed properly? Packet loss or some other network failure in transit? Where would I start troubleshooting this? We're running Tomcat and Apache on Windows server 2008-R2 in a vmware virtualized server.

    Read the article

  • ATI firepro will not detect a second DVI-D monitor

    - by John
    OK so weird issue here. I have previously been running 6 screens off of 3 of the older ATI firepro graphics cards but they had a problem with the heat sink getting too hot and warping the PCB resulting in total failure of the card, to replace my three dead cards I purchased a new-type ATI firepro with the newer heat sink design. I'm only using one at the moment to make sure they've fixed the problem before I waste more money on 2 more cards but this is where things start to get weird. The Firepro's only have one port on them, they connect to two monitors via a splitter cable going from the one port to two DVI connectors for the screens. When I plug two identical monitors in via their DVI inputs not matter what I do windows and Catalyst will only detect one screen. However if I use the VGA input on one of the screens with a VGA - DVI adaptor to plug it in to the card it works fine. This confuses me greatly. I'm currently using the ATI Firepro 2270 Graphics card with identical DELL U2311H screens. I can post the rest of the system spec as well if needed but I wouldn't have thought it would make much difference as it had no problem handling 6 screens before the graphics cards failed. Naturally both catalyst and ATI drivers are the most current version. ATI tech support has been absolutely zero help, they seemed to get stumped as soon as I verified that both screens were plugged in and connected properly. Anyone have any ideas?

    Read the article

  • Mailman delivery troubles

    - by stanigator
    I have apparently posted at the wrong place (superuser.com) for this question, so I'll just repost it here. Hope those of you who read both sites are not going to be offended. It's about mailing list management software called Mailman from GNU. Here are the details: Hosting provider: Vlexofree Domain: www.sysil.com with Google Apps Mailing List created from hosting cpanel: [email protected] I have registered a list of subscribers, and tried sending an email to [email protected]. I got the following error message: Delivery to the following recipient failed permanently: [email protected] Technical details of permanent failure: Google tried to deliver your message, but it was rejected by the recipient domain. We recommend contacting the other email provider for further information about the cause of this error. The error that the other server returned was: 550 550-5.1.1 The email account that you tried to reach does not exist. Please try 550-5.1.1 double-checking the recipient's email address for typos or 550-5.1.1 unnecessary spaces. Learn more at 550 5.1.1 http://mail.google.com/support/bin/answer.py?answer=6596 23si6479194ewy.44 (state 14). ----- Original message ----- MIME-Version: 1.0 Received: by 10.216.90.136 with SMTP id e8mr1469147wef.110.1264220118960; Fri, 22 Jan 2010 20:15:18 -0800 (PST) Date: Fri, 22 Jan 2010 20:15:18 -0800 Message-ID: <[email protected]> Subject: From: Stanley Lee <[email protected]> To: [email protected] Content-Type: multipart/alternative; boundary=0016e6dab0931bccc3047dcd2f1e - Show quoted text - Is there any way of fixing this problem? I would like to be able to have this mailing list to work through my hosting and domain. Thanks in advance.

    Read the article

  • SSL connection error for only one site (of many) on server

    - by Matt Lacey
    I have a server running many websites, each with SSL. One of the sites is now refusing connections over SSL. This was previously working and I'm looking for assistance in determining what has been changed. Here's the situation: http://site1.com/ - works https://site1.com/ - works http://site2.com/ - works https://site2.com/ - Doesn't work (but did previously) Both sites are on the same server (Win Server 2003 SP2 - IIS6) Both sites use certificates from the same authority and are both valid (according to IIS). As far as I can tell, both sites have certificates configured identically in IIS. (Checked by a manual/visual check of properties, side by side) Through use of OpenSSL I can see that there's a "ssl handshake failure" when trying to connect to site2 using https. What could be the cause of this? How can I investigate further? Without SSL connections being available to this site, users are unable to log in or register. :( disclaimer: I'm not a server admin and not responsible for the box. Yes, there are wider issues here but I need to get this working again first.

    Read the article

  • How to restart boot Windows 7 after upgrading to a SSHD on SONY VAIO with recovery discs?

    - by Boris Okun
    The original HDD on my Sony VAIO still works, but has a damaged sector 0 and I was constantly prompted to replace the HDD because of the imminent failure. I created recovery discs as instructed, used a USB external HDD for complete back up (including Windows image back up). After installing the SSHD and using recovery discs to upload Windows and boot, I am getting the Windows welcome screen. Right after that, I'm getting the following message: Windows couldn't complete the installation. To install Windows on this computer, restart the installation. I have tried repeating the process many times all kinds of different ways and I still receive the same message. Also, when I tried to change to partitioning as the other option offered, I get the message: Windows Setup could not configure Windows to run on this computer's hardware. All troubleshooting for hardware and PCU came out solid. I tried to load the image back up from the external drive, but can't load the driver. The computer doesn't see it. Does anyone have a clue or has encountered something similar?

    Read the article

  • Linux Live CD only works when Windows is in Legacy mode?

    - by Vee
    I have asked a similar question before and no one was able to help me but I think it was because I wasn't phrasing it properly. This is a better restatement of the question. I have Windows 8 and Linux Mint dual booted on my pc. When I tried to boot the Linux from a CD ROM only, it would give me the following error: error: failure reading sector 0x0 from 'hd1' error: you need to load the kernel first. Press any key to continue... The Linux Mint works fine but otherwise, but it gives this error when I try to boot from CD. The boot Linux from CD only worked when I changed the Windows to Legacy mode in the BIOS settings. When I changed it back to UEFI, it would give the same error. Why is this? How can I fix it? I am somewhat new so is there anything else I should know about all of this? NOTE: I changed the Linux into UEFI mode using boot-repair but that still did not solve the problem when I tried to boot from CD ROM.

    Read the article

  • Generalized strategy for file server virtualization in Xenserver

    - by Jamie
    I'm not shopping as much as I'm looking for some guidance on good idea / bad idea strategies. I'm sure I'm not in the "best practices" budget range. Currently, I have 3 dell poweredges running xenserver in a pool. Each node has a ubuntu file server, serving about 6TB. One is the primary, the other two are rsync targets for backup. The 6TB is stored on their respective local storage disks as an LVM of 3x2tb virtual disks. The fileserver VM disks are also stored on the node local disks. Each node also runs a smattering of light-weight VMs for web, development, windows VMs, and stuff like that. Several of those VM's disks reside on a QNAP NAS to play with live migration. These VM's are often clients of the primary file server (like all the mail, web content, user files are stored on the file server, not on the mail, web, and samba VMs). This all works fine, and is a major step up for us. The downside is that the QNAP is a single point of failure. And the only thing the QNAP is doing is serving migratable VM images, not client data. Someday the poweredge local arrays will be full, and we will have to reinvent ourselves again. Is it wise to have heavywieght vms (like the fileserver, with its 6+ TB disks) on a SAN or NAS? Would it be better to keep the VMs lightweight, have the VM images on a SAN or NAS, and use 2 or more NAS act as NFS-serving file appliances? A hybrid SAN/NAS that can serve iscsi for images and NFS for the client vms? It seems like live-magration would be a misnomer if you have to migrate a fileserver with its entire 6+ TB disk. I recognize there are plenty of ways to skin the cat. We've already skinned it a few ways. What makes sense?

    Read the article

  • Strange Internet Connection issues

    - by Nodren
    I'm attempting to troubleshoot problems with a laptop computer(HP 8510w) while it's connected to a server of mine via Remote Desktop. I double checked all the settings on the win2k3 server for remote desktop to verify that remote desktop isn't what's causing the disconnect issues, and other people using different computers/laptops can all connect to remote desktop correctly with no issues. These problems happen specifically when the laptop is connected via wifi(several different wifi sources, so it's not an ISP issue) as well as connected via a Verizon data card. However there's no network downtime when the laptop is resting in the docking station and plugged into the network with the remote desktop server. These problems have also only recently occurred since a recent hard drive failure in which a new hard drive was purchased and the laptop had a fresh install of windows xp professional. There's no special software used on this machine, just office 2003. So my question is, what could cause two types of internet access to fail while other types do not? If it is infact related to the win2k3 server, why is this particular laptop getting disconnected when others are not and are all on at the same time?

    Read the article

  • Mystery 0xc0000142 error on starting java from a service, as a different user.

    - by cpf
    This is a very convoluted setup, but effectively this is what goes down: Manager service (which I don't have control over) running as admin user X starts my executable, which then starts Java as user Y using the standard c# StartInfo.Username/Password controls. Now, from a basic (not elevated or anything, just admin) command prompt I can run that executable, and Java pops up and works fine, running perfectly under the user it should be. When the service runs the same executable, however, Java silently fails. The only hint I see is this series of events in the event viewer: Service starts "Application popup: java.exe - Application Error : The application was unable to start correctly (0xc0000142). Click OK to close the application. " (googling this reveals a lot of scam sites telling me to use their "free antivirus to fix 0xc0000142 errors easy!"... sigh) Service stops (the java shutdown propagated, which is supposed to happen) And here's what process explorer has for the failure: As you can see, everything shows as a success. Now, I think this might have something to do with the permissions (the user java.exe is running under has traverse permission for the entire drive and full permissions to Directory A, which is where the .jar is), but I just can't fathom how something that works fine from the command line (and, this is an upgrade, the previous system without the user-switching aspect works fine from the service) can fail with such a cryptic message and little showing up in logs.

    Read the article

  • Running KVM/XEN/Hyper-V VMs from a RAM disk, is this possible? Practical?

    - by Ausmith1
    Currently I'm using ESX (v3 and v4) to test a scripted OS (Windows 2003) and application install DVD. The DVD ISO (8GB) is mounted on a 1Gbps NFS datastore and the VMDK's (20GB) are on an SSD mounted via NFS over a 10Gbps link. It still takes a lot longer than I'd really like for to run through a test iteration and I'm wondering if mounting the virtual disks and ISO on a RAM disk on the same server as the hypervisor is running on would be worth my while. I can dedicate a server to this VM and 32GB of RAM in the system should be adequate to do the trick I'd guess. (1GB hypervisor OS, 28GB RAM disk and 2GB for the VM is < the 32GB available to me) Since hosting a RAM disk within ESX does not seem possible I'm open to trying KVM/Xen/Hyper-V. KVM would probably be my first choice of these three. Anyone out there tried this? Bear in mind this is purely for a test run of the installer, the VM will be discarded as soon as the test is completed so I'm not worried about losing data from the remote possibility of a power failure.

    Read the article

  • Standards for documenting/designing infrastructure

    - by Paul
    We have a moderately complex solution for which we need to construct a production environment. There are around a dozen components (and here I'm using a definition of "component" which means "can fail independently of other components" - e.g. an Apache server, a Weblogic web app, an ftp server, an ejabberd server, etc). There are a number of weblogic web apps - and one thing we need to decide is how many weblogic containers to run these web apps in. The system needs to be highly available, and communications in and out of the system are typically secured by SSL Our datacentre team will handle things like VLAN design, racking, server specification and build. So the kinds of decisions we still need to make are: How to map components to physical servers (and weblogic containers) Identify all communication paths, ensure all are either resilient or there's an "upstream" comms path that is resilient, and failover of that depends on all single-points of failure "downstream". Decide where to terminate SSL (on load balancers, or on Apache servers, for instance). My question isn't really about how to make the decisions, but whether there are any standards for documenting (especially in diagrams) the design questions and the design decisions. It seems odd, for instance, that Visio doesn't have a template for something like this - it has templates for more physical layout, and for more logical /software architecture diagrams. So right now I'm using a basic Visio diagram to represent each component, the commms between them with plans to augment this with hostnames, ports, whether each comms link is resilient etc, etc. This all feels like something that must been done many times before. Are there standards for documenting this?

    Read the article

  • Mongo daemon restarts after replica set issue

    - by Matt Beckman
    We had a recent election in our replica set (2 read nodes; 1 write node) that changed the primary node. Curious as to why this occurred, I started looking through the logs to find out what happened. It appears that mongoNode2 could not communicate with mongoNode3. When both nodes could not communicate, it appears that this caused the services on mongoNode2 and mongoNode3 to restart, eventually resulting in a new primary after the services had been started again. Thu Jun 23 08:27:28 [ReplSetHealthPollTask] DBClientCursor::init call() failed Thu Jun 23 08:27:28 [ReplSetHealthPollTask] replSet info mongoNode3:27017 is down (or \ slow to respond): DBClientBase::findOne: transport error: mongoNode3:27017 query: { \ replSetHeartbeat: "myReplSet", v: 3, pv: 1, checkEmpty: false, from: \ "mongoNode2:27017" } Thu Jun 23 08:27:29 got kill or ctrl c or hup signal 15 (Terminated), will \ terminate after current cmd ends Thu Jun 23 08:27:29 [interruptThread] now exiting Thu Jun 23 08:27:29 dbexit: Is there any reason that the mongo service would restart due to a DBClientCursor::init call() failure? Is this a known bug? It should be noted that mongoNode2 and mongoNode3 are VMs on the same VMware host. MongoNode1 is not on the same host, and it did not have any issues with the service. However, I did not have any other reports of issues with other VMs on the VMware host.

    Read the article

  • Reliable custom Windows shortcut keys?

    - by Peter Baer
    I have global Windows shortcut keys assigned to several different cmd.exe instances. I do this by creating shortcuts to cmd.exe on my desktop, and assigning each one a unique shortcut key (for example, CTRL + SHIFT + U). Pretty basic stuff. I'm using Win2K8 (R1 and R2). This works just fine... most of the time. But with infuriating regularity, sometimes it doesn't. Or it will work with a long delay (many seconds). It doesn't matter what app currently has focus (it can even be one of the command prompts). It doesn't matter what keys I assign (I've tried a few variations of WIN, CTRL and SHIFT). I did notice that this is often, but not always, correlated with explorer.exe struggling in some way or another (say, an explorer window opened to a file share that's unavailable, or an app being unresponsive, or whatever). In other words the shortcut key handling appears to be very sensitive to unrelated system activity. Note that whenever I have this problem I can always successfully ALT + TAB to the window I want to get to, but that's tedious. I use the shortcuts to these command windows hundreds of times a day so even a 1% failure rate becomes really annoying. Is there a way to fix this, or is there some third-party utility out there that will RELIABLY intercept custom key combinations to bring focus to whatever apps I want, in a way that is independent of other system activity? ADDENDUM: There is a property of the Windows shortcuts that I would not want to lose if switching to a third-party hotkey tool: Windows shortcuts are idempotent. Once you've launched a shortcut to some app, pressing the shortcut key combo again takes you to the already launched process - it does not launch a new process.

    Read the article

  • Problems installing Windows service via Group Policy in a domain

    - by CraneStyle
    I'm reasonably new to Group Policy administration and I'm trying to deploy an MSI installer via Active Directory to install a service. In reality, I'm a software developer trying to test how my service will be installed in a domain environment. My test environment: Server 2003 Domain Controller About 10 machines (between XP SP3, and server 2008) all joined to my domain. No real other setup, or active directory configuration has been done apart from things like getting DNS right. I suspect that I may be missing a step in Group Policy that says I need to grant an explicit permission somewhere, but I have no idea where that might be or what it will say. What I've done: I followed the documentation from Microsoft in How to Deploy Software via Group Policy, so I believe all those steps are correct (I used the UNC path, verified NTFS permissions, I have verified the computers and users are members of groups that are assigned to receive the policy etc). If I deploy the software via the Computer Configuration, when I reboot the target machine I get the following: When the computer starts up it logs Event ID 108, and says "Failed to apply changes to software installation settings. Software changes could not be applied. A previous log entry with details should exist. The error was: An operations error occurred." There are no previous log entries to check, which is weird because if it ever actually tried to invoke the windows installer it should log any sort of failure of my application's installer. If I open a command prompt and manually run: msiexec /qb /i \\[host]\[share]\installer.msi It installs the service just fine. If I deploy the software via the User Configuration, when I log that user in the Event Log says that software changes were applied successfully, but my service isn't installed. However, when deployed via the User configuration even though it's not installed when I go to Control Panel - Add/Remove Programs and click on Add New Programs my service installer is being advertised and I can install/remove it from there. (this does not happen when it's assigned to computers) Hopefully that wall of text was enough information to get me going, thanks all for the help.

    Read the article

  • Missing whole disk device in OpenSolaris

    - by Jeff Mc
    I have begun experimenting with Solaris and ZFS as a NAS. All was going very smoothly until I had a drive failure. When I replaced the drive, I no longer have a device file mapped to the whole disk. /dev/dsk/c7t3d0 does not exist but c7t2d0 and c7t4d0 both do. Also the sd@3,0:wd file under the /devices/ tree is non-existent. Do I have to prepare/partition the disk somehow to cause the whole disk device to exist? Here are a few outputs that might be useful. jeffmc@ats-ds2:/dev/dsk$ zpool status pool: datapool state: DEGRADED status: One or more devices could not be opened. Sufficient replicas exist for the pool to continue functioning in a degraded state. action: Attach the missing device and online it using 'zpool online'. see: http://www.sun.com/msg/ZFS-8000-2Q scrub: none requested config: NAME STATE READ WRITE CKSUM datapool DEGRADED 0 0 0 mirror-0 DEGRADED 0 0 0 c7t2d0 ONLINE 0 0 0 c7t3d0 UNAVAIL 0 0 0 cannot open mirror-1 ONLINE 0 0 0 c7t4d0 ONLINE 0 0 0 c7t5d0 ONLINE 0 0 0 jeffmc@ats-ds2:/dev/dsk$ zpool replace datapool c7t3d0 cannot open 'c7t3d0': no such device in /dev/dsk must be a full path or shorthand device name jeffmc@ats-ds2:/dev/dsk$ sudo format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c7t0d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@0,0 1. c7t1d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@1,0 2. c7t2d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@2,0 3. c7t3d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@3,0 4. c7t4d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@4,0 5. c7t5d0 /pci@0,0/pci8086,3599@6/pci8086,330@0/pci1014,2cc@7,1/sd@5,0

    Read the article

  • How to organise storage for media content such as video and music?

    - by thor
    Currently, we have a single server hosting all content: music, video and software. This content is downloaded by users through HTTP. Now free space is coming to an end and we are exploring different ways of extending our storage capacity. We want to do it cheap, simple and reliable (protected from disk/ server faults). Currenly, we see two ways: Add a couple of cheap servers with 4 disks (RAID1 ?), run some distributed file-system on top, like GlusterFS. Pros: hopefully, we will see all our disks as single flat file system, just dump content into it and be done. Cons: could be tricky in configuration and handling of faults. Add a couple of cheap servers, all running HTTP servers. Each piece of content (be it a music file or video) is placed on randomly selected two servers. Pros: don't have to deal with RAID, as content is duplicated; single server failure does not bring down any part of content; doubled distribution capacity (as any signle file could be downloaded from any of two servers hosting it). Cons: requires some scripting on part of distribution of content, adding/ removing servers. Do we miss any other ways? Which of the aforementioned options seems to be the best?

    Read the article

  • RPC Server Unavailable on Hyper-V cluster when moving resources after the host adapter has failed

    - by Doug Luxem
    On a Windows 2008 R2 SP1 cluster running Hyper-V, a lost network connectivity on the primary host interface. The interface was rapidly flapping up and down, and this was later determined to be caused by a faulty switch port. As this was a clustered server, the host interface was not fault tolerant (seeing as how the whole server was fault tolerant), so connectivity to the host was going up and down. The Hyper-V guests were completely unaffected by the network outage as they used a dedicated trunk on the server separate from the host interface. Additionally, dedicated interfaces for the cluster and live migration networks were fine. In order to diagnose the server, I tried to move all resources (Hyper-V Guests) to other nodes through Failover Cluster Manager. These moves failed with an error RPC Server Unavailable. The only way to move resources was by shutting down the guests, stopping the cluster service on the Node A, allowing other nodes to take ownership of the resources, and restarting the guests. A few other notes: All nodes have Client for MS Networks and File & Printer Sharing enabled on the Cluster and LM networks. Node A was accessible over cluster and LM networks from other nodes (these are private, cluster-only networks); pingable, CIFs, etc. Accessing \\NODEA is done over the Host adapters, as you would expect in this case and is the reason for the RPC Server Unavailable error with that adapter being down. My questions here are - Is there a way to still use Live Migration in a failure scenario such as this to prevent shutting down the Hyper-V guests? How can the network be reconfigured in the future so that the cluster service attempts to use the cluster and/or live migration networks to issue the RPC requests?

    Read the article

  • Booting Ubuntu as VM with KVM on Ubuntu 12.04

    - by CrazycodeMonkey
    I am trying to boot my very first VM using KVM. I have Ubuntu 12.04 installed, i made sure the BIOS had the right virtualization flag enabled for intel processor by running kvm-ok. I have researched this on google and all the instructions that i have found so far are outdated. for e.g. most instructions talk about booting a virtual machine with the following commands qemu-img create -f qcow2 foo.img 100G --- create a virtual disk for your VM kvm --name foo -m 1024 -hda foo.img -cdrom whatever.iso -boot d -- This runs kvm. This command line is incomplete. First you need to be root to run this. Second- it is missing option for the video device. When you run this command you get the following error "Could not initialize SDL(No available video device) - exiting" Googled this error and looked it up on stackover flow http://stackoverflow.com/questions/4841908/sdl-init-failure-reason-is-no-available-video-device The answer provided here does not work on Ubuntu 12.04 Googled this problem further and found out that i need to specify a video device so I finally ran the following command sudo kvm --name mymachine -m 8096 -hda myimage.img --cdrom ubuntu.iso -boot d -vga cirruss -k en-us -vmc :0 This was after I had created the myimage.img image on the drive. Now this command does not give me an error but it just hangs. Does anyone have clear instructions on how to run a VM using KVM on Ubuntu?

    Read the article

  • LDAP Account Locked Out Sporadically after Password change - Finding the source of invalid attempts

    - by CityView
    On a small network of machines (<1000) we have a user whose account is being locked out after an indeterminate interval following a password change. We are having severe difficulties finding the source of the invalid logon attempts and I would appreciate it greatly if some of you could go through your thought process and the checks you would perform in order to fix the problem. All I know for sure is that the account is locked out several (5+) times a day, I can't even be sure it's due to failed login attempts as there is no record of failure until the account is locked. So far I have tried; Logging the account out of everything we can think of and back in with the new password Scanning the user's box for any non standard software which might perform an LDAP lookup Checking all installed services on our production boxes to check none are attempting to run under the account Changing the user back to their old password (Problem persists so perhaps password change is a red herring) Wireshark on a box where lots of LDAP authentication is performed - Rejects only occur after account is already locked out Clearing the credential cache in - Control Panel - User Accounts - Advanced Looking at the local I'm at a loss for what to try. I am happy to try any suggestions you have in order to diagnose the issue. I think my question boils down to a simple request; I need a technique for deriving the source (Application/Host) of the invalid login attempts which are causing the account to be locked. I'm not sure if that's even possible but I suspect there must be more I can try. Many thanks, CityView

    Read the article

  • SSD suddenly full

    - by Daniel
    Today the hard drive of our server was suddenly full. The disk usage always stayed around 50 % in the weeks and months before (old data is regularly expunged from the server). I deleted 10 GB of files in /tmp, which strangely freed 51 GB. Here is what I did: root@***:~# df -h Dateisystem Size Used Avail Use% Eingehängt auf /dev/sda3 139G 137G 0 100% / tmpfs 3,9G 0 3,9G 0% /lib/init/rw udev 3,9G 116K 3,9G 1% /dev tmpfs 3,9G 0 3,9G 0% /dev/shm /dev/sda1 985M 25M 910M 3% /boot root@***:/var# du -hs * 3,3M backups 438M cache 9,4G lib 4,0K local 12K lock 76M log 24K mail 4,0K opt 88K run 184K spool 10G tmp 12K www root@***:/var/tmp# find -type f -print0 | xargs -0 rm root@***:/var/tmp# df -h Dateisystem Size Used Avail Use% Eingehängt auf /dev/sda3 139G 81G 51G 62% / tmpfs 3,9G 0 3,9G 0% /lib/init/rw udev 3,9G 116K 3,9G 1% /dev tmpfs 3,9G 0 3,9G 0% /dev/shm /dev/sda1 985M 25M 910M 3% /boot Any explanation as to why deleting 10 GB in /tmp gave me back 51 GB on the disk? Could this point to an SSD failure? Are there any tools for Debian to test SSD health? I already have checked syslog. The first entry relating to this incidient is a mysql message: 1:22:02 [ERROR] /usr/sbin/mysqld: Disk is full writing... So I have absolutely no idea what caused this.

    Read the article