Search Results

Search found 34688 results on 1388 pages for 'default document'.

Page 269/1388 | < Previous Page | 265 266 267 268 269 270 271 272 273 274 275 276  | Next Page >

  • Drawing on a webpage – HTML5 - IE9

    - by nmarun
    So I upgraded to IE9 and continued exploring HTML5. Now there’s this ‘thing’ called Canvas in HTML5 with which you can do some cool stuff. Alright what IS this Canvas thing anyways? The Web Hypertext Application Technology Working Group says this: “The canvas element provides scripts with a resolution-dependent bitmap canvas, which can be used for rendering graphs, game graphics, or other visual images on the fly.” The Canvas element has two only attributes – width and height and when not specified they take up the default values of 300 and 150 respectively. Below is what my HTML file looks like: 1: <!DOCTYPE html> 2: <html lang="en-US"> 3: <head> 4: <script type="text/javascript" src="CustomScript.js"></script> 5: <script src="jquery-1.4.4.js" type="text/javascript"></script 6:  7: <title>Draw on a webpage</title> 8: </head> 9: <body> 10: <canvas id="canvas" width="500" height="500"></canvas> 11: <br /> 12: <input type="submit" id="submit" value="Clear" /> 13: <h4 id="currentPosition"> 14: 0, 0 15: </h4> 16: <div id="mousedownCoords"></div> 17: </body> 18: </html> In case you’re wondering, this is not a MVC or any kind of web application. This is plain ol’ HTML even though I’m writing all this in VS 2010. You see this is a very simple, ‘gimmicks-free’ html page. I have declared a Canvas element on line 10 and a button on line 11 to clear the drawing board. I’m using jQuery / JavaScript show the current position of the mouse on the screen. This will get updated in the ‘currentPosition’ <h4> tag and I’m using the ‘mousedownCoords’ to write all the places where the mouse was clicked. This is what my page renders as: The rectangle with a background is our canvas. The coloring is due to some javascript (which we’ll see in a moment). Now let’s get to our CustomScript.js file. 1: jQuery(document).ready(function () { 2: var isFirstClick = true; 3: var canvas = document.getElementById("canvas"); 4: // getContext: Returns an object that exposes an API for drawing on the canvas 5: var canvasContext = canvas.getContext("2d"); 6: fillBackground(); 7:  8: $("#submit").click(function () { 9: clearCanvas(); 10: fillBackground(); 11: }); 12:  13: $(document).mousemove(function (e) { 14: $('#currentPosition').html(e.pageX + ', ' + e.pageY); 15: }); 16: $(document).mouseup(function (e) { 17: // on the first click 18: // set the moveTo 19: if (isFirstClick == true) { 20: canvasContext.beginPath(); 21: canvasContext.moveTo(e.pageX - 7, e.pageY - 7); 22: isFirstClick = false; 23: } 24: else { 25: // on subsequent clicks, draw a line 26: canvasContext.lineTo(e.pageX - 7, e.pageY - 7); 27: canvasContext.stroke(); 28: } 29:  30: $('#mousedownCoords').text($('#mousedownCoords').text() + '(' + e.pageX + ',' + e.pageY + ')'); 31: }); 32:  33: function fillBackground() { 34: canvasContext.fillStyle = '#a1b1c3'; 35: canvasContext.fillRect(0, 0, 500, 500); 36: canvasContext.fill(); 37: } 38:  39: function clearCanvas() { 40: // wipe-out the canvas 41: canvas.width = canvas.width; 42: // set the isFirstClick to true 43: // so the next shape can begin 44: isFirstClick = true; 45: // clear the text 46: $('#mousedownCoords').text(''); 47: } 48: })   The script only looks long and complicated, but is not. I’ll go over the main steps. Get a ‘hold’ of your canvas object and retrieve the ‘2d’ context out of it. On mousemove event, write the current x and y coordinates to the ‘currentPosition’ element. On mouseup event, check if this is the first time the user has clicked on the canvas. The coloring of the canvas is done in the fillBackground() function. We first need to start a new path. This is done by calling the beginPath() function on our context. The moveTo() function sets the starting point of our path. The lineTo() function sets the end point of the line to be drawn. The stroke() function is the one that actually draws the line on our canvas. So if you want to play with the demo, here’s how you do it. First click on the canvas (nothing visible happens on the canvas). The second click draws a line from the first click to the current coordinates and so on and so forth. Click on the ‘Clear’ button, to reset the canvas and to give your creativity a clean slate. Here’s a sample output: Happy drawing! Verdict: HTML5 and IE9 – I think we’re on to something big and great here!

    Read the article

  • Log Blog

    - by PointsToShare
    © 2011 By: Dov Trietsch. All rights reserved Logging – A log blog In a another blog (Missing Fields and Defaults) I spoke about not doing a blog about log files, but then I looked at it again and realized that this is a nice opportunity to show a simple yet powerful tool and also deal with static variables and functions in C#. My log had to be able to answer a few simple logging rules:   To log or not to log? That is the question – Always log! That is the answer  Do we share a log? Even when a file is opened with a minimal lock, it does not share well and performance greatly suffers. So sharing a log is not a good idea. Also, when sharing, it is harder to find your particular entries and you have to establish rules about retention. My recommendation – Do Not Share!  How verbose? Your log can be very verbose – a good thing when testing, very terse – a good thing in day-to-day runs, or somewhere in between. You must be the judge. In my Blog, I elect to always report a run with start and end times, and always report errors. I normally use 5 levels of logging: 4 – write all, 3 – write more, 2 – write some, 1 – write errors and timing, 0 – write none. The code sample below is more general than that. It uses the config file to set the max log level and each call to the log assigns a level to the call itself. If the level is above the .config highest level, the line will not be written. Programmers decide which log belongs to which level and thus we can set the .config differently for production and testing.  Where do I keep the log? If your career is important to you, discuss this with the boss and with the system admin. We keep logs in the L: drive of our server and make sure that we have a directory for each app that needs a log. When adding a new app, add a new directory. The default location for the log is also found in the .config file Print One or Many? There are two options here:   1.     Print many, Open but once once – you start the stream and close it only when the program ends. This is what you can do when you perform in “batch” mode like in a console app or a stsadm extension.The advantage to this is that starting a closing a stream is expensive and time consuming and because we use a unique file, keeping it open for a long time does not cause contention problems. 2.     Print one entry at a time or Open many – every time you write a line, you start the stream, write to it and close it. This work for event receivers, feature receivers, and web parts. Here scalability requires us to create objects on the fly and get rid of them as soon as possible.  A default value of the onceOrMany resides in the .config.  All of the above applies to any windows or web application, not just SharePoint.  So as usual, here is a routine that does it all, and a few simple functions that call it for a variety of purposes.   So without further ado, here is app.config  <?xml version="1.0" encoding="utf-8" ?> <configuration>     <configSections>         <sectionGroup name="applicationSettings" type="System.Configuration.ApplicationSettingsGroup, System, Version=2.0.0.0, Culture=neutral, ublicKeyToken=b77a5c561934e089" >         <section name="statics.Properties.Settings" type="System.Configuration.ClientSettingsSection, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" requirePermission="false" />         </sectionGroup>     </configSections>     <applicationSettings>         <statics.Properties.Settings>             <setting name="oneOrMany" serializeAs="String">                 <value>False</value>             </setting>             <setting name="logURI" serializeAs="String">                 <value>C:\staticLog.txt</value>             </setting>             <setting name="highestLevel" serializeAs="String">                 <value>2</value>             </setting>         </statics.Properties.Settings>     </applicationSettings> </configuration>   And now the code:  In order to persist the variables between calls and also to be able to persist (or not to persist) the log file itself, I created an EventLog class with static variables and functions. Static functions do not need an instance of the class in order to work. If you ever wondered why our Main function is static, the answer is that something needs to run before instantiation so that other objects may be instantiated, and this is what the “static” Main does. The various logging functions and variables are created as static because they do not need instantiation and as a fringe benefit they remain un-destroyed between calls. The Main function here is just used for testing. Note that it does not instantiate anything, just uses the log functions. This is possible because the functions are static. Also note that the function calls are of the form: Class.Function.  using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.IO; namespace statics {       class Program     {         static void Main(string[] args)         {             //write a single line             EventLog.LogEvents("ha ha", 3, "C:\\hahafile.txt", 4, true, false);             //this single line will not be written because the msgLevel is too high             EventLog.LogEvents("baba", 3, "C:\\babafile.txt", 2, true, false);             //The next 4 lines will be written in succession - no closing             EventLog.LogLine("blah blah", 1);             EventLog.LogLine("da da", 1);             EventLog.LogLine("ma ma", 1);             EventLog.LogLine("lah lah", 1);             EventLog.CloseLog(); // log will close             //now with specific functions             EventLog.LogSingleLine("one line", 1);             //this is just a test, the log is already closed             EventLog.CloseLog();         }     }     public class EventLog     {         public static string logURI = Properties.Settings.Default.logURI;         public static bool isOneLine = Properties.Settings.Default.oneOrMany;         public static bool isOpen = false;         public static int highestLevel = Properties.Settings.Default.highestLevel;         public static StreamWriter sw;         /// <summary>         /// the program will "print" the msg into the log         /// unless msgLevel is > msgLimit         /// onceOrMany is true when once - the program will open the log         /// print the msg and close the log. False when many the program will         /// keep the log open until close = true         /// normally all the arguments will come from the app.config         /// called by many overloads of logLine         /// </summary>         /// <param name="msg"></param>         /// <param name="msgLevel"></param>         /// <param name="logFileName"></param>         /// <param name="msgLimit"></param>         /// <param name="onceOrMany"></param>         /// <param name="close"></param>         public static void LogEvents(string msg, int msgLevel, string logFileName, int msgLimit, bool oneOrMany, bool close)         {             //to print or not to print             if (msgLevel <= msgLimit)             {                 //open the file. from the argument (logFileName) or from the config (logURI)                 if (!isOpen)                 {                     string logFile = logFileName;                     if (logFileName == "")                     {                         logFile = logURI;                     }                     sw = new StreamWriter(logFile, true);                     sw.WriteLine("Started At: " + DateTime.Now.ToString("yyyy-MM-dd HH:mm:ss"));                     isOpen = true;                 }                 //print                 sw.WriteLine(msg);             }             //close when instructed             if (close || oneOrMany)             {                 if (isOpen)                 {                     sw.WriteLine("Ended At: " + DateTime.Now.ToString("yyyy-MM-dd HH:mm:ss"));                     sw.Close();                     isOpen = false;                 }             }         }           /// <summary>         /// The simplest, just msg and level         /// </summary>         /// <param name="msg"></param>         /// <param name="msgLevel"></param>         public static void LogLine(string msg, int msgLevel)         {             //use the given msg and msgLevel and all others are defaults             LogEvents(msg, msgLevel, "", highestLevel, isOneLine, false);         }                 /// <summary>         /// one line at a time - open print close         /// </summary>         /// <param name="msg"></param>         /// <param name="msgLevel"></param>         public static void LogSingleLine(string msg, int msgLevel)         {             LogEvents(msg, msgLevel, "", highestLevel, true, true);         }           /// <summary>         /// used to close. high level, low limit, once and close are set         /// </summary>         /// <param name="close"></param>         public static void CloseLog()         {             LogEvents("", 15, "", 1, true, true);         }           }     }   }   That’s all folks!

    Read the article

  • Ubuntu GUI crash when LightDM enters, unable to login

    - by Cesar
    This issue happened spounteniously, i don´t know what could have cause it as i wasn´t using the PC when it happened. I ruled out any messing around with the setting as the user doesn´t know how to enter the BIOS, doesn´t have the sudo password and was only using firefox and libreoffice when it happened. After the plymouth sequence i get this error. https://www.dropbox.com/s/uf1xdkqkw9alvcu/IMAG0252.jpg And this option: https://www.dropbox.com/s/tpivkgjkx2spa3v/IMAG0253.jpg I follow each option and nothing happens after that. The issue persist after rebooting. I choose the other options to see if anything happens, i either get back to option 1 or doesn´t show anything anormal. (I have pictures i someone wants to know) What i found weird is that event though the error is possitioned in the chip, however ubuntu 10.04 and 12.04 run fine in a live CD I saw that some people are having issues when LightDM has a non default wallpaper, but i use a default one. Thanks in advance.

    Read the article

  • blurry lines between web application context layer, service layer and data access layer in spring

    - by thenaglecode
    I Originally asked this question in SO but on advice I have moved the question here... I'll admit I'm a spring newbie, but you can correct me if I'm wrong, this one liner looks kinda fishy in a best practices sort of way: @RepositoryRestResource(collectionResourceRel="people"...) public interface PersonRepository extends PagingAndSortingRepository<Person, Long> For those who are unaware, the following does many things: It is an interface definition that can be registered in an application context as a jpa repository, automagically hooking up all the default CRUD operations within a persistence context (that is externally configured). and also configures default controller/request-mapping/handler functionality at the namespace "/people" relative to your configured dispatcher servlet-mapping. Here's my point. I just crossed 3 conceptual layers with one line of code! this feels against my seperation-of-concern instincts but i wanted to hear your opinion. And for the sake of being on a question and answer site, I would like to know whether there is a better way of seperating these different layers - Service, Data, Controllers - whilst maintaining as minimal configuration as possible

    Read the article

  • An Epic Question "How to call a method when the page loads"

    - by Arunkumar Ramamoorthy
    Quite often, there comes a question in OTN, with different subjects, all meaning "How to call a method when my ADF page loads?". More often, people tend to take the approach of ADF Phase Listener by overriding before/afterPhase methods.In this blog, we will go through different options in achieving it.1. Method Call Activity as default activity in Taskflow :If the application is built with taskflows, then this is the best suited approach to take. 1.a. Calling a Data Control Method :To call a Data Control method (ex: A method in AMImpl exposed as client interface), simply Drag and Drop the method as Default Method Call Activity, then draw a control flow case from the method to your page. Once after this, drop the taskflow as region in main page. When we run the main page, the Method Call Activity would be called first, and then the page will be rendered.1.b. Calling a Method in Backing Bean: To call a method in the backing bean before pageload, we can follow the similar approach as above. Instead of binding the Method Call Activity to an action/method binding in pagedef, we bind to the method. Insert a Method Call Activity (and make it as default) from the Component Palette. Double click on to select a method to bind. This approach can also be used, to perform some action in backing bean along with calling a method Data Control (just need to add bindings code in backing bean to execute DC method). 2. Using invokeAction Executable :If the application is built with pages and no taskflows are involved, then this option can be taken into consideration.In the page definition of the page, add an invokeAction Executable and bind it to the method needed to be executed. 3. Using combination of Server and Client Listeners : If the page does not have any page definition, then to call a method in backing bean, this approach can be taken. In this, a serverListener would be added at the document level, which would be calling the method in backing bean. Along with this, a clientListener would be added with "load" type (i.e will be triggered when the page loads), which would queue a serverEvent to trigger the method. 4. Using Page Phase Listener :This should be the last resort. Care should be taken when using this approach since the Phase Listener would be called for each request sent by the client.Zeeshan Baig's blog covers this scenario.

    Read the article

  • An Epic Question "How to call a method when the page loads"

    - by Arunkumar Ramamoorthy
    Quite often, there comes a question in OTN, with different subjects, all meaning "How to call a method when my ADF page loads?". More often, people tend to take the approach of ADF Phase Listener by overriding before/afterPhase methods.In this blog, we will go through different options in achieving it.1. Method Call Activity as default activity in Taskflow :If the application is built with taskflows, then this is the best suited approach to take. 1.a. Calling a Data Control Method :To call a Data Control method (ex: A method in AMImpl exposed as client interface), simply Drag and Drop the method as Default Method Call Activity, then draw a control flow case from the method to your page. Once after this, drop the taskflow as region in main page. When we run the main page, the Method Call Activity would be called first, and then the page will be rendered.1.b. Calling a Method in Backing Bean: To call a method in the backing bean before pageload, we can follow the similar approach as above. Instead of binding the Method Call Activity to an action/method binding in pagedef, we bind to the method. Insert a Method Call Activity (and make it as default) from the Component Palette. Double click on to select a method to bind. This approach can also be used, to perform some action in backing bean along with calling a method Data Control (just need to add bindings code in backing bean to execute DC method). 2. Using invokeAction Executable :If the application is built with pages and no taskflows are involved, then this option can be taken into consideration.In the page definition of the page, add an invokeAction Executable and bind it to the method needed to be executed. 3. Using combination of Server and Client Listeners : If the page does not have any page definition, then to call a method in backing bean, this approach can be taken. In this, a serverListener would be added at the document level, which would be calling the method in backing bean. Along with this, a clientListener would be added with "load" type (i.e will be triggered when the page loads), which would queue a serverEvent to trigger the method. 4. Using Page Phase Listener :This should be the last resort. Care should be taken when using this approach since the Phase Listener would be called for each request sent by the client.Zeeshan Baig's blog covers this scenario.

    Read the article

  • What would be the best approach to make revisions of user content?

    - by Kevin Simper
    I have searched and could not find any information about it. What is the best approach to storing revisions? I have a website where the user can write a document which can be fairly long (200-300 lines). How do you determine when to make a revision? Is it not a scalable solution to make a new one whenever the save, because that would be useless to the user when the want to look back, and it would require quite a lot of space. You could use time and say for every 15 minute they are working on it there would be a revision, but that would sometimes be nothing or the whole document have completely changed. I could make a diff from the previous revision, and compare by line and look at how many percent of the lines have been changed. What are other doing revisions?

    Read the article

  • Preventing adult content in a forum

    - by John Doe
    I'm working on a forum that allows images attached to the posts and doesn't require registration. Thing is, I'd like to provide a work-safe navigation option in which the posts with porn images attached aren't shown. The ideas I've come up with are: Making the work-safe option the default and treating all posts with images attached as pornographic, and making them visible only if the user "unchecks" it. Making all posts with images attached not work-safe by default and changing their status to work-safe only after a moderator approved it. Only then they would be visible if the user has the "work-safe" option checked. Does anyone else have an idea? Also, how the big web services deal with this? (YouTube, CraigsList, even StackExchange). By the way, I don't think that "nudity detector" libraries are accurate and they give plenty of false positives and negatives. Thanks!

    Read the article

  • Changing the Game: Why Oracle is in the IT Operations Management Business

    - by DanKoloski
    v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif"; mso-bidi-font-family:"Times New Roman";} Next week, in Orlando, is the annual Gartner IT Operations Management Summit. Oracle is a premier sponsor of this annual event, which brings together IT executives for several days of high level talks about the state of operational management of enterprise IT. This year, Sushil Kumar, VP Product Strategy and Business Development for Oracle’s Systems & Applications Management, will be presenting on the transformation in IT Operations required to support enterprise cloud computing. IT Operations transformation is an important subject, because year after year, we hear essentially the same refrain – large enterprises spend an average of two-thirds (67%!) of their IT resources (budget, energy, time, people, etc.) on running the business, with far too little left over to spend on growing and transforming the business (which is what the business actually needs and wants). In the thirtieth year of the distributed computing revolution (give or take, depending on how you count it), it’s amazing that we have still not moved the needle on the single biggest component of enterprise IT resource utilization. Oracle is in the IT Operations Management business because when management is engineered together with the technology under management, the resulting efficiency gains can be truly staggering. To put it simply – what if you could turn that 67% of IT resources spent on running the business into 50%? Or 40%? Imagine what you could do with those resources. It’s now not just possible, but happening. This seems like a simple idea, but it is a radical change from “business as usual” in enterprise IT Operations. For the last thirty years, management has been a bolted-on afterthought – we pick and deploy our technology, then figure out how to manage it. This pervasive dysfunction is a broken cycle that guarantees high ongoing operating costs and low agility. If we want to break the cycle, we need to take a more tightly-coupled approach. As a complete applications-to-disk platform provider, Oracle is engineering management together with technology across our stack and hooking that on-premise management up live to My Oracle Support. Let’s examine the results with just one piece of the Oracle stack – the Oracle Database. Oracle began this journey with the Oracle Database 9i many years ago with the introduction of low-impact instrumentation in the database kernel (“tell me what’s wrong”) and through Database 10g, 11g and 11gR2 has successively added integrated advisory (“tell me how to fix what’s wrong”) and lifecycle management and automated self-tuning (“fix it for me, and do it on an ongoing basis for all my assets”). When enterprises take advantage of this tight-coupling, the results are game-changing. Consider the following (for a full list of public references, visit this link): British Telecom improved database provisioning time 1000% (from weeks to minutes) which allows them to provide a new DBaaS service to their internal customers with no additional resources Cerner Corporation Saved $9.5 million in CapEx and OpEx AND launched a brand-new cloud business at the same time Vodafone Group plc improved response times 50% and reduced maintenance planning times 50-60% while serving 391 million registered mobile customers Or the recent Database Manageability and Productivity Cost Comparisons: Oracle Database 11g Release 2 vs. SAP Sybase ASE 15.7, Microsoft SQL Server 2008 R2 and IBM DB2 9.7 as conducted by independent analyst firm ORC. In later entries, we’ll discuss similar results across other portions of the Oracle stack and how these efficiency gains are required to achieve the agility benefits of Enterprise Cloud. Stay Connected: Twitter |  Face book |  You Tube |  Linked in |  Newsletter

    Read the article

  • Computacenter first partner to offer Oracle Exadata proof-of-concept environment for real-world test

    - by kimberly.billings
    Computacenter (http://www.computacenter.com/), Europe's leading independent provider of IT infrastructure services, recently announced that it is the first partner to offer an Oracle Exadata 'proof-of concept' environment for real-world testing. This new center, combined with Computacenter's extensive database storage skills, will enable organisations to accurately test Oracle Exadata with their own workloads, clearly demonstrating the case for migration. For more information, read the press release. Are you planning to migrate to Oracle Exadata? Tell us about it! var gaJsHost = (("https:" == document.location.protocol) ? "https://ssl." : "http://www."); document.write(unescape("%3Cscript src='" + gaJsHost + "google-analytics.com/ga.js' type='text/javascript'%3E%3C/script%3E")); try { var pageTracker = _gat._getTracker("UA-13185312-1"); pageTracker._trackPageview(); } catch(err) {}

    Read the article

  • Expanding on requestaudit - Tracing who is doing what...and for how long

    - by Kyle Hatlestad
    One of the most helpful tracing sections in WebCenter Content (and one that is on by default) is the requestaudit tracing.  This tracing section summarizes the top service requests happening in the server along with how they are performing.  By default, it has 2 different rotations.  One happens every 2 minutes (listing up to 5 services) and another happens every 60 minutes (listing up to 20 services).  These traces provide the total time for all the requests against that service along with the number of requests and its average request time.  This information can provide a good start in possibly troubleshooting performance issues or tracking a particular issue.   [Read More] 

    Read the article

  • Changes to File Store Provider in UCM PS3

    - by Kevin Smith
    In the recent PS3 release of UCM (11.1.1.4.0) there are some significant changes to the File Store Provider (FSP) configuration. For new PS3 installs (not upgrades from PS2) the FSP default storage rule includes a dispersion rule that will change the web-layout and vault paths by adding dispersion directories to the paths to limit the number of files in the vault and web-layout directories. What that means is that if you install a new PS3 UCM instance and migrate content in from a previous version of UCM the web URL will change. That is a critical problem for web sites and just general document management. See below for some details on the FSP configuration in PS3 and how you can change the default behavior. use the link below to read the rest of this post where I describe the issue in detaill and provide instructions for how to modify a PS3 instance to use the old format for the web-layout path.

    Read the article

  • Scripting Part 1

    - by rbishop
    Dynamic Scripting is a large topic, so let me get a couple of things out of the way first. If you aren't familiar with JavaScript, I can suggest CodeAcademy's JavaScript series. There are also many other websites and books that cover JavaScript from every possible angle.The second thing we need to deal with is JavaScript as a programming language versus a JavaScript environment running in a web browser. Many books, tutorials, and websites completely blur these two together but they are in fact completely separate. What does this really mean in relation to DRM? Since DRM isn't a web browser, there are no document, window, history, screen, or location objects. There are no events like mousedown or click. Trying to call alert('hello!') in DRM will just cause an error. Those concepts are all related to an HTML document (web page) and are part of the Browser Object Model or Document Object Model. DRM has its own object model that exposes DRM-related objects. In practice, feel free to use those sorts of tutorials or practice within your browser; Many of the concepts are directly translatable to writing scripts in DRM. Just don't try to call document.getElementById in your property definition!I think learning by example tends to work the best, so let's try getting a list of all the unique property values for a given node and its children. var uniqueValues = {}; var childEnumerator = node.GetChildEnumerator(); while(childEnumerator.MoveNext()) { var propValue = childEnumerator.GetCurrent().PropValue("Custom.testpropstr1"); print(propValue); if(propValue != null && propValue != '' && !uniqueValues[propValue]) uniqueValues[propValue] = true; } var result = ''; for(var value in uniqueValues){ result += "Found value " + value + ","; } return result;  Now lets break this down piece by piece. var uniqueValues = {}; This declares a variable and initializes it as a new empty Object. You could also have written var uniqueValues = new Object(); Why use an object here? JavaScript objects can also function as a list of keys and we'll use that later to store each property value as a key on the object. var childEnumerator = node.GetChildEnumerator(); while(childEnumerator.MoveNext()) { This gets an enumerator for the node's children. The enumerator allows us to loop through the children one by one. If we wanted to get a filtered list of children, we would instead use ChildrenWith(). When we reach the end of the child list, the enumerator will return false for MoveNext() and that will stop the loop. var propValue = childEnumerator.GetCurrent().PropValue("Custom.testpropstr1"); print(propValue); if(propValue != null && propValue != '' && !uniqueValues[propValue]) uniqueValues[propValue] = true; } This gets the node the enumerator is currently pointing at, then calls PropValue() on it to get the value of a property. We then make sure the prop value isn't null or the empty string, then we make sure the value doesn't already exist as a key. Assuming it doesn't we add it as a key with a value (true in this case because it makes checking for an existing value faster when the value exists). A quick word on the print() function. When viewing the prop grid, running an export, or performing normal DRM operations it does nothing. If you have a lot of print() calls with complicated arguments it can slow your script down slightly, but otherwise has no effect. But when using the script editor, all the output of print() will be shown in the Warnings area. This gives you an extremely useful debugging tool to see what exactly a script is doing. var result = ''; for(var value in uniqueValues){ result += "Found value " + value + ","; } return result; Now we build a string by looping through all the keys in uniqueValues and adding that value to our string. The last step is to simply return the result. Hopefully this small example demonstrates some of the core Dynamic Scripting concepts. Next time, we can try checking for node references in other hierarchies to see if they are using duplicate property values.

    Read the article

  • Fiscal Cliff

    - by Carolyn Cozart
    As December 31, 2012 quickly approaches, so does the deadline to extend the Bush Era Tax Cuts which were extended under the Budget Control Act of 2011.  PeopleSoft realizes that there may be some customer anxiety over the delayed withholding tables. PeopleSoft is unable to move forward with delivering the tax changes until we get the official ruling and withholding tables from the IRS.  Please be assured that our legislative analysts are in the loop and are monitoring this situation daily.  Any changes will be included in a special posting. We have created a Knowledge Document in My Oracle Support, Document ID 1332295.1 to keep you up to date on the pending changes.

    Read the article

  • How to Navigate Directly From One Table to Another in Word 2013

    - by Lori Kaufman
    Jumping to a specific page in Word is a common task and easy to do using the Find and Replace dialog box. You can also use this same tab to jump from one table directly to the next table in your document. Your cursor does not have to be in a table to jump to the next table. Put the cursor in any paragraph or table and press F5 or use the Ctrl + G keystroke combination to open the Find and Replace dialog box. The Go To tab is automatically selected. Select Table from the Go to what list and click Next. The next table in your document is selected and the Find and Replace dialog box stays open.    

    Read the article

  • OUD as a OAM Identity Store

    - by Sylvain Duloutre
    Since 11gR2, OUD can be used natively as a OAM Identity Store. Select  "OUD: Oracle Unified Directory" as Store Type as described here. As an alternate solution, you can also configure OVD as Identity Store with OAM and then configure LDAP adapter for OVD with OUD details.Configuring Identity store for OAM is documented here. Choose "OVD: Oracle Virtual Directory" as store type and provide store details as per the document. Configuring LDAP adapter for OVD is documented here. Provide your OUD details required as per the document.

    Read the article

  • How do I remove SUN Java and use OpenJDK instead?

    - by Adel Ramadan
    As a programmer I use java for learning to code in Netbeans. I installed Sun java 6 long time ago over openJDK that came with my ubuntu just cause it seemed more responsive... Now that oracle left the repos I wanted something easy to handle to install and uninstall, so I want to Remove completely sun java 6 from my computer and set as default OPENjdk....and openjre. I already have installed OpenJDK and OPENjre...but not marked as default. Besides I want to clean Sun java from here, dont wanna get messy ^^. Running ubuntu 11.10

    Read the article

  • Does Bing support anything like Google's First Click Free program?

    - by Dan Fabulich
    Google has a program for webmasters called First Click Free. To implement First Click Free, you need to allow all users who find a document on your site via Google search to see the full text of that document, even if they have not registered or subscribed to see that content. The user's first click to your content area is free. However, once that user clicks a link on the original page, you can require them to sign in or register to read further. The user must be able to see the full content of a multi-page article. You can allow this by displaying all content on a single page to both Googlebot and users. Alternatively, you can use cookies to make sure that a user can visit each page of a multi-page article before being asked for registration or payment. Does Bing support anything like this?

    Read the article

  • PostgreSQL 9.1, pgadmin III, Ubuntu 12.04 LTS, support functions

    - by Chaz SLiger
    When pgAdmin III is used to open a PostgreSQL database the following message appears. There does not seem to be any obvious package listed in the Ubuntu Software Center for this. The server lacks instrumentation functions. pgadmin III uses some support functions that are not available by default in all PostgreSQL versions. These enable some tasks that make life easier when dealing with log files and configuration files. The adminpack is installed and activated by default if you are running the one-click installer of PostgreSQL. On Unix, you may have to install the contrib package, either with your package installer tool or by compilation.

    Read the article

  • Ubuntu 14.04LTS - runtime video card configuration through Radeon driver

    - by RJVB
    How does one configure Radeon video cards when using the open source Radeon driver - power profile, vsync, etc? Why I try the widely documented solution (against overheating) that worked for me under LMDE (confirmed with kernels up to 3.12.6), I get the following error: $ sudo cat /sys/class/drm/card0/device/power_profile default $ sudo sh -c "echo mid > /sys/class/drm/card0/device/power_profile" sh: echo: I/O error Exit 1 And when I try suggestions from Arch's ATI wiki my modifications are simply ignored: $ sudo cat /sys/class/drm/card0/device/power_dpm_force_performance_level auto $ sudo sh -c "echo high> /sys/class/drm/card0/device/power_dpm_force_performance_level" $ sudo cat /sys/class/drm/card0/device/power_dpm_force_performance_level auto Is this something Ubuntu specific, or something introduced with the 3.13 version of the Radeon driver? I'm encountering this on 2 laptops, one with a Radeon HD6290 (integrated GPU), the other with a discrete RV710 card. The RV710 needs a specific power setting to prevent overheating under LMDE, fortunately it doesn't seem to overheat with the Ubuntu default setting.

    Read the article

  • Oracle Database 11g Release 2 Now Available on 32-bit and x64 Windows

    - by jenny.gelhausen
    Oracle Database 11g Release 2 provides the foundation for IT to successfully deliver more information with higher quality of service, reduce the risk of change within IT, and make more efficient use of their IT budgets. By deploying Oracle Database 11g Release 2 as their data management foundation, organizations can utilize the full power of the world's leading database. Now Oracle Database 11g Release 2 is available for organizations using 32-bit and x64 Windows. Download either on OTN var gaJsHost = (("https:" == document.location.protocol) ? "https://ssl." : "http://www."); document.write(unescape("%3Cscript src='" + gaJsHost + "google-analytics.com/ga.js' type='text/javascript'%3E%3C/script%3E")); try { var pageTracker = _gat._getTracker("UA-13185312-1"); pageTracker._trackPageview(); } catch(err) {}

    Read the article

  • Silverlight Relay Commands

    - by George Evjen
    v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Normal 0 false false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} I am fairly new at Silverlight development and I usually have an issue that needs research every day. Which I enjoy, since I like the idea of going into a day knowing that I am  going to learn something new. The issue that I am currently working on centers around relay commands. I have a pretty good handle on Relay Commands and how we use them within our applications. <Button Command="{Binding ButtonCommand}" CommandParameter="NewRecruit" Content="New Recruit" /> Here in our xaml we have a button. The button has a Command and a CommandParameter. The command binds to the ButtonCommand that we have in our ViewModel RelayCommand _buttonCommand;         /// <summary>         /// Gets the button command.         /// </summary>         /// <value>The button command.</value>         public RelayCommand ButtonCommand         {             get             {                 if (_buttonCommand == null)                 {                     _buttonCommand = new RelayCommand(                         x => x != null && x.ToString().Length > 0 && CheckCommandAvailable(x.ToString()),                         x => ExecuteCommand(x.ToString()));                 }                 return _buttonCommand;             }         }   In our relay command we then do some checks with a lambda expression. We check if the command  parameter is null, is the length greater than 0 and we have a CheckCommandAvailable method that will tell  us if the button is even enabled. After we check on these three items we then pass the command parameter to an action method. This is all pretty straight forward, the issue that we solved a few days ago centered around having a control that needed to use a Relay Command and this control was a nested control and was using a different DataContext. The example below illustrates how we handled this scenario. In our xaml usercontrol we had to set a name to this control. <Controls3:RadTileViewItem x:Class="RecruitStatusTileView"     xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation"     xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml"     xmlns:d="http://schemas.microsoft.com/expression/blend/2008"     xmlns:mc="http://schemas.openxmlformats.org/markup-compatibility/2006"      xmlns:Controls1="clr-namespace:Telerik.Windows.Controls;assembly=Telerik.Windows.Controls"      xmlns:Controls2="clr-namespace:Telerik.Windows.Controls;assembly=Telerik.Windows.Controls.Input"      xmlns:Controls3="clr-namespace:Telerik.Windows.Controls;assembly=Telerik.Windows.Controls.Navigation"      mc:Ignorable="d" d:DesignHeight="400" d:DesignWidth="800" Header="{Binding Title,Mode=TwoWay}" MinimizedHeight="100"                             x:Name="StatusView"> Here we are using a telerik RadTileViewItem. We set the name of this control to “StatusView”. In our button control we set our command parameters and commands different than the example above. <HyperlinkButton Content="{Binding BigBoardButtonText, Mode=TwoWay}" CommandParameter="{Binding 'Position.PositionName'}" Command="{Binding ElementName=StatusView, Path=DataContext.BigBoardCommand, Mode=TwoWay}" /> This hyperlink button lives in a ListBox control and this listbox has an ItemSource of PositionSelectors. The Command Parameter is binding to the Position.Position property of that PositionSelectors object. This again is pretty straight forward again. What gets a bit tricky is the Command property in the hyperlink. It is binding to the element name we created in the user control (StatusView) Because this hyperlink is in a listbox and is in the item template it doesn’t have a direct handle on the DataContext that the RadTileViewItem has so we have to make sure it does. We do that by binding to the element name of status view then set the path to DataContext.BigBoardCommand. BigBoardCommand is the name of the RelayCommand in the view model. private RelayCommand _bigBoardCommand = null;         /// <summary>         /// Gets the big board command.         /// </summary>         /// <value>The big board command.</value>         public RelayCommand BigBoardCommand         {             get             {                 if (_bigBoardCommand == null)                 {                     _bigBoardCommand = new RelayCommand(x => true, x => AddToBigBoard(x.ToString()));                 }                 return _bigBoardCommand;             }         } From there we check for true again and then call the action and pass in the parameter that we had as the command parameter. What we are working on now is a bit trickier than this second example. In the above example we are only creating this TileViewItem with this name “StatusView” once. In another part of our application we are generating multiple TileViewItems, so we cannot set the name in the control as we cant have multiple controls with the same name. When we run the application we get an error that reads that the value is out of expected range. My searching has led me to think we cannot have multiple controls with the same name. This is today’s problem and Ill post the solution to this once it is found.

    Read the article

  • Ubuntu doesn't give the intended screen resolution

    - by JMCF125
    I have recently created a Ubuntu 12.04.2 64 bit virtual machine on VirtualBox, and I am not very used to Linux (I used Linux Mint for a few weeks some time ago), so please refer the full name of stuff, not just "the what-not-command". The problem is I can't set the full resolution my computer supports (I think it is 1366 by 768), I have found similar questions and tried most of the respective solutions, thy did not work. If I type xrandr to the terminal I get: xrandr: Failed to get size of gamma for output default Screen 0: minimum 640 x 480, current 1024 x 768, maximum 1024 x 768 default connected 1024x768+0+0 0mm x 0mm 1024x768 61.0* 800x600 61.0 640x480 60.0 As you can see, the maximum is too low. And in the settings of the screen (I mean, with GUI) only 1024x768 and 800x600 appear. I don't remember exactly which answer of those questions, but it was one in the terminal (again, with xrandr) that made the resolution I wanted appear (although it gave an error when selected, not even changing to the 1366x768 resolution first and then back to 1024x768).

    Read the article

  • Would you use UML if it kept stakeholders from requesting changes frequently?

    - by Huperniketes
    As much as programmers hate to document their code/system and draw UML (especially, Sequencing, Activity and State machine diagrams) or other diagramming notation, would you agree to do it if it kept managers from requesting a "minor change" every couple of weeks? IOW, would you put together visual models to document the system if it helped you demonstrate to managers what the effect of changes are and why it takes so long to implement them? (Edited to help programmers understand what type of answer I'm looking for.) 2nd edit: Restating my question again, "Would you be willing to use some diagramming notation, against your better nature as a programmer, if it helped you manage change requests?" This question isn't asking if there might be something wrong with the process. It's a given that there's something wrong with the process. Would you be willing to do more work to improve it?

    Read the article

< Previous Page | 265 266 267 268 269 270 271 272 273 274 275 276  | Next Page >