Search Results

Search found 8185 results on 328 pages for 'capture card'.

Page 276/328 | < Previous Page | 272 273 274 275 276 277 278 279 280 281 282 283  | Next Page >

  • What is the advantage of not running as root? [closed]

    - by Shmuel Brill
    Possible Duplicate: What's wrong with always being root? All modern brands of Linux highly discourage (or disable) one from running as root instead of a normal user. I do not understand why. As a "normal" user, one could Download a rouge program from the internet. Run it (After all, one isn't root, what can it do). It installs itself in .bashrc or .xinitrc It writes a rouge "sudo" and "su" and adds . to the path Not noticing that . is in path, one runs sudo. The rouge program now has root password and can do anything it wants in the system. Even if 3-6 doesn't happen, the program could still Be part of a botnet. Read all files in the home directory and send them back (mine for SS#, Credit Card numbers, bank account numbers, etc). Send spam. Run a backdoor server to allow an attacker a chance to connect to the machine to determine vulnerabilities. It seems that the whole "permissions" thing (root/non-root) is just to prevent amateur crackers from getting into the system, so the question is: Is there a point in avoiding running as root, and is there a way to protect oneself if one wants to run unsafe code?

    Read the article

  • switchless Infiniband between two servers on RHEL 6.3

    - by exfizik
    I have 2 servers running RHEL 6.3 which have 2 port Infiniband cards >lspci | grep -i infini 07:00.0 InfiniBand: QLogic Corp. IBA7322 QDR InfiniBand HCA (rev 02) I'm interested in connecting them directly to each other bypassing an Infiniband switch (which I don't have). Quick googling showed that at least in some configurations it's possible. I installed all RedHat Infiniband packages with yum groupinstall "Infiniband Support". However, ibv_devinfo shows that both ports in each card are down, which indicates that cables are not connected. But the cable is connected, although the LEDs are off on the cards (not a good sign). Another source of confusion for me is that according to this, RedHat doesn't come with OFED packages and I'm slightly hesitant to install them from source due to the lack of RedHat support for them... So where am I going with this? The questions I have are: is it possible to have a switchless/direct Infiniband connection between two servers the way I described above? If it's possible, do I have to use the OFED packages or can I configure everything with just the packages coming with RHEL. Why are the LEDs off on my servers even though the cable is connected? Any additional input/advice/pointers would be appreciated. P.S. I followed this guide for installation instructions. The Infiniband cards are clearly recognized by my OS and the rdma service is running. Update: I have opensm installed. When I run it it says: OpenSM 3.3.13 Command Line Arguments: Log File: /var/log/opensm.log ------------------------------------------------- OpenSM 3.3.13 Entering DISCOVERING state Using default GUID 0x1175000076e4c8 SM port is down and stays at that point.

    Read the article

  • Howo to get Multipath IO with Dell MD3600i into active/active setup?

    - by Disco
    I'm desperately trying to improve performance of my SAN connection. Here's what i have: [root@xnode1 dell]# multipath -ll mpath1 (36d4ae520009bd7cc0000030e4fe8230b) dm-2 DELL,MD36xxi [size=5.5T][features=3 queue_if_no_path pg_init_retries 50][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=200][active] \_ 18:0:0:0 sdb 8:16 [active][ready] \_ 19:0:0:0 sdd 8:48 [active][ghost] \_ 20:0:0:0 sdf 8:80 [active][ghost] \_ 21:0:0:0 sdh 8:112 [active][ready] And multipath.conf : defaults { udev_dir /dev polling_interval 5 prio_callout none rr_min_io 100 max_fds 8192 user_friendly_names yes path_grouping_policy multibus default_features "1 fail_if_no_path" } blacklist { device { vendor "*" product "Universal Xport" } } devices { device { vendor "DELL" product "MD36xxi" path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And sessions. [root@xnode1 dell]# iscsiadm -m session tcp: [13] 10.0.51.220:3260,1 iqn.1984-05.com.dell:powervault.md3600i.6d4ae520009bd7cc000000004fd7507c tcp: [14] 10.0.50.221:3260,2 iqn.1984-05.com.dell:powervault.md3600i.6d4ae520009bd7cc000000004fd7507c tcp: [15] 10.0.51.221:3260,2 iqn.1984-05.com.dell:powervault.md3600i.6d4ae520009bd7cc000000004fd7507c tcp: [16] 10.0.50.220:3260,1 iqn.1984-05.com.dell:powervault.md3600i.6d4ae520009bd7cc000000004fd7507c I'm getting very poor read performance : dd if=/dev/mapper/mpath1 of=/dev/null bs=1M count=1000 The SAN is configured as follows: CTRL0,PORT0 : 10.0.50.220 CTRL0,PORT1 : 10.0.50.221 CTRL1,PORT0 : 10.0.51.220 CTRL1,PORT1 : 10.0.51.221 And on the host : IF0 : 10.0.50.1 IF1 : 10.0.51.1 (Dual 10GbE Ethernet Card Intel DA2) It's connected to a 10gbE switch dedicated for SAN traffic. My questions being; why the connection is set up as 'ghost' and not 'ready' like an active/active configuration ?

    Read the article

  • How powerful of a PC do you need to edit HD videos?

    - by Xeoncross
    I have a Core2Quad Q8200 (2.3GHz) with 4GB of RAM, a 512MB PCIe video card, and a SATA-2 HD. Yet it still isn't fast enough to edit 720i/p video in Sony Vegas or Adobe Premiere/Aftereffects. My RAM usage never peaks over 1.6GB, but my CPU cores make it to 95% quick! Right now the preview panes in all these programs lag to bad to actually work on the videos. I get to see 1-3 frames every second or two! So how fast do I have to go? At what point will my CPU be fast enough to actually edit these videos? I have to assume that regular people and their regular sub $2k computers can actually work with this footage. Another way to answer this is, how fast is the PC you used to edit videos? Update: I'ts worth noting that now that I have Adobe Pre/AF CS4 I am more interested in getting that working than my older Vegas 6. If you didn't have to re-run RAM preview every, single, time you made one change it would be my answer. But since I like to test many filters and effects before choosing one - I have to re-render a 1-sec section of footage over-and-over and it drives me nuts waiting. Perhaps a motherboard with Dual Xeon chips or something would be able to handle this. It would probably be as much as a dual-crossfire setup and would also speed up other applications.

    Read the article

  • Bash Script - Traffic Shaping

    - by Craig-Aaron
    hey all, I was wondering if you could have a look at my script and help me add a few things to it, How do I get it to find how many active ethernet ports I have? and how do I filter more than 1 ethernet port How I get this to do a range of IP address? Once I have a few ethenet ports I need to add traffic control to each one #!/bin/bash # Name of the traffic control command. TC=/sbin/tc # The network interface we're planning on limiting bandwidth. IF=eth0 # Network card interface # Download limit (in mega bits) DNLD=10mbit # DOWNLOAD Limit # Upload limit (in mega bits) UPLD=1mbit # UPLOAD Limit # IP address range of the machine we are controlling IP=192.168.0.1 # Host IP # Filter options for limiting the intended interface. U32="$TC filter add dev $IF protocol ip parent 1:0 prio 1 u32" start() { # Hierarchical Token Bucket (HTB) to shape bandwidth $TC qdisc add dev $IF root handle 1: htb default 30 #Creates the root schedlar $TC class add dev $IF parent 1: classid 1:1 htb rate $DNLD #Creates a child schedlar to shape download $TC class add dev $IF parent 1: classid 1:2 htb rate $UPLD #Creates a child schedlar to shape upload $U32 match ip dst $IP/24 flowid 1:1 #Filter to match the interface, limit download speed $U32 match ip src $IP/24 flowid 1:2 #Filter to match the interface, limit upload speed } stop() { # Stop the bandwidth shaping. $TC qdisc del dev $IF root } restart() { # Self-explanatory. stop sleep 1 start } show() { # Display status of traffic control status. $TC -s qdisc ls dev $IF } case "$1" in start) echo -n "Starting bandwidth shaping: " start echo "done" ;; stop) echo -n "Stopping bandwidth shaping: " stop echo "done" ;; restart) echo -n "Restarting bandwidth shaping: " restart echo "done" ;; show) echo "Bandwidth shaping status for $IF:" show echo "" ;; *) pwd=$(pwd) echo "Usage: tc.bash {start|stop|restart|show}" ;; esac exit 0 thanks

    Read the article

  • Not recognizing second monitor after hibernate (Windows 7, Dell D630 laptop)

    - by Brooks Moses
    I have a Dell Latitude D630 laptop which I've recently updated to Windows 7 64-bit. (The Dell site confirms that it's Windows-7-compatible.) Normally it lives in a docking station with a second monitor connected to the DVI port on the docking station, and I use the second monitor in a multi-monitor configuration with the laptop screen. Sometimes I undock the laptop and use it separately. Here's the problem: If I hibernate the laptop while undocked, and then power it back up in the docking station, it does not recognize the second monitor. By which I mean that not only does it not share the desktop onto the second monitor, but if I go into the control panel for display settings and press "Detect", it does not even detect the existence of the second monitor. I can tell it to "use the VGA port anyway" for a second monitor, but the monitor is connected to a DVI port on the docking station, so that doesn't do anything useful. If I entirely reboot the laptop while it's connected to the docking station, it has no problem recognizing the second monitor and using it. But then, if I hibernate, undock, de-hibernate while undocked and rehibernate, and then re-dock and de-hibernate, it's back to not recognizing the second monitor again. I'm reasonably certain that this is not a limitation of the hardware; this worked fine on Windows XP. I'm currently using the Windows 7 driver for my video card. I attempted to use the video driver from the Dell website for this laptop, but Dell only provides Vista 64-bit drivers, not Windows 7 64-bit drivers. Their "Windows 7 compatibility" page suggests that the Vista drivers should work, but when I attempted to install the driver, it gave me a "this operating system not supported" error and refused to install. Any further ideas?

    Read the article

  • SIP and NAT routers?

    - by OverTheRainbow
    Hello SIP was not built with NAT routers in mind, and I'd like to get to the bottom of this issue to check what needs to be done on all devices so it works with NAT routers, and understand in what context it just can't be used and I should check more NAT-friendly alternatives like IAX. A picture being worth a thousand words, here's the layout I need to use: http://img62.imageshack.us/img62/4077/sipandnatrouters.jpg The PBX server is located in the private LAN behind a NAT router connected to the Internet (I know it'd be easier if it were located in the public network, but this router doesn't support DMZ's so the server has to be in the private network) A couple of (soft|hard)phones are located on the same LAN and connected to the PBX server, along with a PSTN gateway (Linksys 3102 or a Digium PCI card) Remote users using (soft|hard)phones are located somewhere on the Net with dynamic IP's and are also located behind NAT routers I may or may not have control over the local NAT router where the PBX server is located, but I have no control over the remote NAT routers, either because the users don't have the computer knowledge to map ports or because the routers are off-limit (eg. web cafés, hotel LAN's, etc.) Is it possible to configure the PBX server, the (soft|hard)phones, and the PSTN gateway so that the all conversations work fine, no matter the endpoints (POTS caller/local phone, POTS caller/remote phone, local phones, remote phone/local phone)? In which cases may I expect problems, and are there solutions? FWIW, I'm leaning toward using Freeswitch, but I could end up using Asterisk if there are technical advantages to it in this context. Thank you for any info.

    Read the article

  • Windows Server 2008 R2 SP1 Drivers Missing Would Not Install?

    - by bleepzter
    I am building my dev machine with WS2008R2SP1. I consider Windows Server as the best development environment for C# since I tend to focus on server-centric (integration) applications. The desktop flavor of Windows (7) doesn't play nicely with things like Commerce Server or BizTalk... so I to like stick to the environment I develop for. Previously I used to develop inside of VM's but I've found that it is super inefficient and tends to take a toll on the laptops. (I've gone through two of them in 6 months). Problem is that I multiple devices that do not want to be recognized by Windows: My machine is Dell Precision M4500: Intel Core i7-Q740, 1TB HDD, 8GB RAM, Dell re-branded Broadcom DW1501 802x11n Half-Mini Card, Dell re-branded Broadcom DW375 Bluetooh Module, Intel 82577LM Gigabit Network connection NVidia Quadro FX1800 Graphics The devices in question are the Dell rebranded broadcom network and bluetooth adapters: Broadcom USH: USB\VID_0A5C&PID_5800&REV_0101&MI_00 USB\VID_0A5C&PID_5800&MI_00 DW375 Bluetooth Module USB\VID_413C&PID_8187&REV_0517 USB\VID_413C&PID_8187 When I ran the broadcom installers I get "Operating System not supported" which I think is a big oversight on Broadcom's part. Why check for system version string? UGHGHGH Moreover if I try to manually force the driver in windows... I get an error: Driver Management concluded the process to install driver FileRepository\btwampsecfl.inf_amd64_neutral_d8fc2b85d035ed47\btwampsecfl.inf for Device Instance ID USB\VID_0A5C&PID_5800&MI_00\7&66DE6C9&0&0000 with the following status: 0xe0000217. '- or - Driver Management concluded the process to install driver FileRepository\btwampfl.inf_amd64_neutral_d4c4acf036c61299\btwampfl.inf for Device Instance ID USB\VID_413C&PID_8187\90004EEEF5A6 with the following status: 0xe0000217. I googled the 0xe0000217 error code and it says Bad service install section in the driver inf file... Any ideas on how to fix this? I also tried the post by BetaIQ on MSDN Forum, unfortunately the links to the driver package included in the post were dead :( PS. On a side note I also do mobile development for Android, iOS, and Windows Phone, and BB. Having the bluetooth is quite useful with mobile devices.

    Read the article

  • Macbook Pro 2010 Ethernet Jumbo Frame(9k MTU) Support?

    - by Troggy
    Has anyone been able to use jumbo frame support on their 2010 Macbook Pros? This is kind of negative news here, but I am seeing many reports that this is not available anymore due to Apple's choice of network card in the new machines. I cannot set my MTU speed over 1500 on my new 2010 MBP i7, but my old early 2008 MBP (Core2) has the 9000 MTU setting for use. Everything I have is setup to use jumbo frames and I thought apple kept that feature in their "pro" lineup. It sounds like the Mac Pro still has it. Did they decide to use a chipset that doesn't support it? I am trying to pinpoint some solid chipset numbers and the feature support. Maybe they just need to update the drivers? Is there some more official information about this feature? This might seem minor, but this is really frustrating if apple removed this feature from their pro laptop line. From what I have read so far, it sounds like I am not alone in my frustrations with this. http://discussions.info.apple.com/message.jspa?messageID=12258067 http://discussions.apple.com/thread.jspa?messageID=12130158 Anyone have any experience or further knowledge about this issue ... beyond typing my question into google and giving the top 5 results as answers? :)

    Read the article

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Increasing SQL Server / Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/SQL Server VM all the RAM I can (12GB) & SQL Server RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL Server VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • how to grep ip from ifconfig output

    - by Registered User
    Following is my ifconfig output eth0 Link encap:Ethernet UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:28 Base address:0x2000 eth1 Link encap:Ethernet inet addr:192.168.1.2 Bcast:192.168.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:36497 errors:0 dropped:0 overruns:0 frame:14515 TX packets:44884 errors:1352 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:20781745 (20.7 MB) TX bytes:17776225 (17.7 MB) Interrupt:17 Base address:0xc000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:12 errors:0 dropped:0 overruns:0 frame:0 TX packets:12 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:720 (720.0 B) TX bytes:720 (720.0 B) virbr0 Link encap:Ethernet inet addr:192.168.122.1 Bcast:192.168.122.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:24 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:4416 (4.4 KB) vmnet1 Link encap:Ethernet inet addr:192.168.185.1 Bcast:192.168.185.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:24 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) vmnet8 Link encap:Ethernet inet addr:192.168.207.1 Bcast:192.168.207.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:25 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) I want to do some thing grep that I see the IP corresponding to each LAN card? Is that possible? How can it be achieved?

    Read the article

  • Installing SATA dvd burner on machine with no spare SATA ports/connectors

    - by Faheem Mitha
    Greetings. I have the following motherboard Tyan Thunder K8WE S2895A2NRF Motherboard - extended ATX - nForce Pro 2200/2050 - Socket 940 - UDMA133, Serial ATA-300 (RAID) - 2 x Gigabit Ethernet - FireWire - 6-1 channel audio This is part of a computer that was assembled in the winter of 2006/2007. The user manual says the following with regard to SATA Integrated SATAII Generation 1 Controllers (from NForce Professional 2200) Two integrated dual port SATA II controllers Four SATA connectors support up to four drives 3 Gb/s per direction per channel NvRAID v2.0 support Supports RAID 0, 1, 0+1 and JBOD. I just purchased a SATA DVD burner. Here is the page for the product http://www.amazon.ca/gp/product/B002QGDWLK/ The problem I am facing is that I already have 4 SATA drives installed. I don't want to remove any of them. However, I want the DVD burner above installed as well. The person I am consulting with here (Bombay, India) tells me that my four available SATA ports are filled, and that my only option is to install a SATA card into the one free PCI slot on the motherboard. However, he says that with this setup I will not be able to boot from the DVD drive. Are these statements correct, and what are my other options if any? Even it the statements in the last para are true, I suppose I could use one of the motherboard connectors/ports there are currently being used with the hard drives with the DVD drive, and use the "add-on" connector with one of the hard drives. Not all the 4 hard drives need to be bootable. BTW, despite having read through http://en.wikipedia.org/wiki/Serial_ATA#Cables.2C_connectors.2C_and_ports I am fuzzy on the differences between connectors, cables and ports. Thanks in advance.

    Read the article

  • How can I stream audio signals from various devices/computers to my home server?

    - by Breakthrough
    I currently have a headless home server set up (running Ubuntu 12.04 server edition) running a simple Apache HTTP server. The server is near an audio receiver, which controls a set of indoor and outdoor speakers in my home. Recently, my father purchased a Bluetooth adapter, which our various laptops and cellphones can connect to, outputting the music to the speakers. I was hoping to find a solution that worked over Wi-Fi, namely because it won't cost anything (I already have a server with an audio card), and it doesn't depend on Bluetooth. Is there any cross-platform (preferably free and open-source) solution that I can use which will allow me to stream audio to my home server, over my home network, from a wide variety of devices (laptops running Windows/Linux or cellphones running Android/BB/iOS)? I need something that works at least with Windows and Android. Also, just to clairfy, I want something that simply allows devices to connect to my server and output an audio signal without any action on the server end (since it's a server hidden away near my receiver). Any subsequent connection attempt should be dropped, so only one device can be in control of the stereo at once.

    Read the article

  • My hard drive seems to be overheating... what should I do?

    - by George Edison
    After a cold boot, the hard drive in my notebook jumps to 56? within an hour or so of idling. Is 56? a cause for alarm? Notes: The notebook is on a flat desk and none of the vents are obstructed. The video card is currently at 55? and the CPU at 50?. It's a Western Digital 250GB hard drive. SMART reports the drive healthy but does warn that: Edit: this problem had a very surprise ending. I inverted the notebook and unscrewed some of the panels on the back (there was one covering the hard drive, and one that provided access to the memory). I couldn't see any dust, so I simply screwed everything back together and powered it on... and it worked! The temperature is now staying at 46?, and it feels notable cooler to the touch. So I can only assume that some internal fan was malfunctioning or something. Whatever the case, it's working now so I won't complain. Edit: I have an SSD now, so temperature isn't as big an issue as it was when I had a mechanical drive.

    Read the article

  • Wireless disconnect randomly with wpa_supplicant reason=2

    - by renenglish
    I installed ubuntu-server 12.04 on my PC , and I use an usb wireless card to join the network. It works ok when I boot up my PC , but the wireless disconnects after a while. I pkill wpa_supplicant and reload the driver rtl8192cu , then it works a again. Then it disconnect again after about a random minutes. Here is the syslog: 22384 May 29 21:49:27 homecenter kernel: [ 6450.459313] wlan1: authenticated 22385 May 29 21:49:27 homecenter kernel: [ 6450.459535] wlan1: associate with f4:ec:38:45:62:74 (try 1) 22386 May 29 21:49:27 homecenter kernel: [ 6450.469080] wlan1: RX AssocResp from f4:ec:38:45:62:74 (capab=0 x431 status=0 aid=3) 22387 May 29 21:49:27 homecenter kernel: [ 6450.469085] wlan1: associated 22388 May 29 21:49:27 homecenter wpa_supplicant[2342]: Associated with f4:ec:38:45:62:74 22389 May 29 21:49:27 homecenter kernel: [ 6450.481933] ADDRCONF(NETDEV_CHANGE): wlan1: link becomes ready 22390 May 29 21:49:27 homecenter wpa_supplicant[2342]: WPA: Key negotiation completed with f4:ec:38:45:62:7 4 [PTK=CCMP GTK=CCMP] 22391 May 29 21:49:27 homecenter wpa_supplicant[2342]: CTRL-EVENT-CONNECTED - Connection to f4:ec:38:45:62: 74 completed (auth) [id=0 id_str=] 22392 May 29 21:49:38 homecenter kernel: [ 6461.472014] wlan1: no IPv6 routers present 22393 May 29 21:49:38 homecenter ntpdate[2263]: step time server 91.189.94.4 offset 0.012758 sec 22394 May 29 21:49:51 homecenter ntpdate[2404]: step time server 91.189.94.4 offset -0.001190 sec 22395 May 29 21:54:38 homecenter kernel: [ 6762.052030] wlan1: deauthenticated from f4:ec:38:45:62:74 (Reas on: 2) 22396 May 29 21:54:38 homecenter wpa_supplicant[2342]: CTRL-EVENT-DISCONNECTED bssid=f4:ec:38:45:62:74 reas on=2 22397 May 29 21:54:38 homecenter kernel: [ 6762.064744] cfg80211: All devices are disconnected, going to re store regulatory settings 22398 May 29 21:54:38 homecenter kernel: [ 6762.064752] cfg80211: Restoring regulatory settings 22399 May 29 21:54:38 homecenter kernel: [ 6762.064757] cfg80211: Calling CRDA to update world regulatory d omain 22400 May 29 21:54:38 homecenter kernel: [ 6762.069938] cfg80211: Ignoring regulatory request Set by core s ince the driver uses its own custom regulatory domain 22401 May 29 21:54:38 homecenter kernel: [ 6762.069943] cfg80211: World regulatory domain updated: 22402 May 29 21:54:38 homecenter kernel: [ 6762.069945] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) 22403 May 29 21:54:38 homecenter kernel: [ 6762.069949] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KH z), (300 mBi, 2000 mBm) 22404 May 29 21:54:38 homecenter kernel: [ 6762.069952] cfg80211: (2457000 KHz - 2482000 KHz @ 20000 KH z), (300 mBi, 2000 mBm) 22405 May 29 21:54:38 homecenter kernel: [ 6762.069956] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KH z), (300 mBi, 2000 mBm) 22406 May 29 21:54:38 homecenter kernel: [ 6762.069959] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KH z), (300 mBi, 2000 mBm) 22407 May 29 21:54:38 homecenter kernel: [ 6762.069962] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KH z), (300 mBi, 2000 mBm)

    Read the article

  • Computer does not switch on after power outage

    - by cristian
    VOLTAGE DROP OFF FOR PC does not restart The other day my pc was turned off due to power outage. Since that time the computer would not turn on again, no sign of life, it seems dead. I did several tests, changed the power outlet and disconnect the wires ... also I have reseated the cards ... but the result is that nothing changes. What can I do? Could there may be damage to the hardware due to the power outage? Note: the voltage drop is not due to a lightning storm and so is not due to damaged components (burnt card etc ...) Original Text: l'altro giorno il pc mi si è spento improvvisamente per calo tensione.... da quel momento non si è piu' riacceso...nessun segnale di vita...sembra proprio morto. Ho fatto diverse prove, cambio presa di alimentazione, scollegare i fili...insomma ho "mischiato le carte"...ma il risultato è che non cambia nulla. Cosa posso fare? cosa puo' essere successo? Possono esserci danni hardware per il calo di tensione? NB: il calo di tensione non e' dovuto ad una saetta e quindi escluderei danni causa temporale (bruciature scheda ecc...) Grazie mille

    Read the article

  • SQL Server 2008 cluster freezing

    - by Ed Leighton-Dick
    We have run into a strange situation in which a SQL Server 2008 single-node cluster hangs. As background, we are rebuilding a Windows Server 2003/SQL Server 2005 two-node cluster using Windows 2008 and SQL Server 2008. Here's the timeline: Evicted the passive node (server B) from the Windows 2003/SQL 2005 cluster. The active node now functions as a single-node cluster with no problems. Wiped server B's disks and installed Windows 2008 and SQL Server 2008 as a single-node cluster. Since we do not want to the two clusters to communicate yet, we left the cluster's private network "heartbeat" adapter unconfigured. The cluster comes up and functions normally. Moved all databases to the new cluster. Cluster continues to function normally. Turned off server A (old cluster) in preparation for rebuilding as the second node of the new cluster. SQL Server instance on server B (new cluster) locks up, even though it should have no knowledge of or interaction with server A. Restarted server A. SQL Server instance on server B (new cluster) immediately begins working again. Things we have tried: The new cluster's name responds to ping and NETBIOS requests, even while the SQL Server is hung. We have confirmed that no IP address is assigned to the old heartbeat adapter, and it is not pulling an IP address from DHCP. Disabling the heartbeat's network card has the same effect. No errors were generated in any logs - Windows or SQL. When the error first occurred, it sat in the hung state for quite some time (well over 10 minutes) before anyone figured out what was going on. This would seem to eliminate any sort of normal cluster timeout in which it would have been searching for the other node (even if one had been configured). Server B is running Windows 2008 SP2, fully patched, and SQL Server 2008 SP1 CU7 (10.0.2775).

    Read the article

  • IIS8 behind a VPN + Windows Server 2012 - how to properly bind IP+Port

    - by ryugen
    This is my first question so I hope I'm going to give you enough information. I'm running Windows Server 2012 within the Hyper-V environment of my Windows 8 machine. Within Windows Server 2012 I'm running a VPN tool based on openVPN to hide my real IP. When I run IIS8 with the VPN disconnected it works flawlessly through the Internet (port 80 forwarded correctly). But as soon as I connect to the VPN I can't reach my site through the domain anymore. Now I tried basically everything I know which is why I'm asking you guys. I tried binding IIS8 to the IP of my virtual ethernet card. I tried changing the priority of the NIC through the "Network and sharing center" via the advanced tab. I used ipconfig /flushdns in case there was something wrong in the DNS handling. Hell, I even turned off the Windows firewall. I also used a port scanner to verify the problem. The webserver is reachable on port 80 with VPN disconnected and immediately gets unreachable on connect. Theoretically both IPs (my regular one AND the VPN) should be reachable or at least not impair the other one right? Do you have any other suggestion? Do I have to route something somewhere somehow?

    Read the article

  • Can't view other computers on Network

    - by Darkart
    Systems: My Machine: Windows 7 Ultimate connected through ethernet into router Her Machine--Other Machine: Windows 7 Ultimate connected through wireless Router:F5D8236-4 N Wireless Router Version 1 Firmware: 2.01.03 (Apr 28 2009) ISP: Comcast Problem: I can not view the "Other Machine" on the network at all. I opened command prompt and ran net view and saw the pc name. I tried pinging the pc and it times out. Went inside the router and tried viewing the computer on the DHCP list and it can not be seen. I restored the router back to default settings and firmware and completely reset the modem and router, and created home group. I went to the other machine to configure home group settings and made sure that both PC's had identical settings. She was able to see my machine but I could not see hers. I restarted both machines and now we cant see each other at all. Also her PC ("Other Machine") had exclamation mark in the wireless icon but was connected just fine. There is no firewalls on currently or anti-virus enabled, and still can not see each other. Right now I am checking for updated drivers for the wireless card, but my question is could it be the router or something hardware related? I have went through all the settings in the Home group and visited most FAQ's and still no luck. Also as it stands I can not view her machine inside the router DHCP Client List :(

    Read the article

  • Increasing MSSQL/Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/MSSQL VM all the RAM I can (12GB) & SQL RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • Black Screen and System Hang - Possibly CPU overheating

    - by Mahesh
    I have this old computer - P4 2.0ghz, 1.2GB RAM and onboard graphics(no external card), 80GBHDD. It has xubuntu installed on it and it regularly hangs when it takes more system resources for say like graphical programs, too many tabs on firefox etc. It just either hangs the system or shows black screen. Tested if it was issue of HD but it wasn't because i have used linux livecd and problem is still the same even if I have removed the HD. I have also tested with USB linux (puppy linux and ubuntu linux on 8gb drives). Tested windows XP as well on this HD and results are the same. Tested another HD on this machine, results are still the same with it. System hangs or goes black screen and requires restart. I thought later it could be thermal heat issue and then applied thermal paste on heatsink but still it fails to work for me. It continues to show symptoms. Another thing which was yet to be tested is changing of CPU fan which was not done because I have not found any fan for old pentium 4 machine in the market. I have to hit online stores (but i am in india and it's hard to find it in online shops which can deliver it to me). So far I don't see this as HD or Monitor or OS issue because I have tested with other HD and results are the same. So it could be either CPU fan or motherboard? What could be possible issue with the hardware?

    Read the article

  • New Computer freezing up at random

    - by Benjamin Frost
    Since I built my system about 4 weeks ago I'v been getting random freezes, Sometimes it can happen directly after startup and sometimes it wont freeze up for 3-4 days of 24/7 running. It seems to be happening under all stress loads but mainly when the CPU is under 10% load. It doesn't give me a BSOD or anything, it simply just freezes and repeats the last sound before the freeze until I shut it down by the power button. I'v re-seated everything in the system except the CPU, Cleaned the RAM sockets and gold fittings. None of the components have been clocked above their factory settings as of yet, don't want to overclock them until I sort out these freezes. Temps are all well under the rated max temps, the highest the temps have been are below CPU: Low load: 16-21°C Full Load (100%) 40-43°C *(From HWMonitor by CPUID) GPU 1: Low Load: 25-30°C Full Load (100%): 45-50°C GPU 2: Low Load: 23-27°C Full Load (100%): 45-50°C *(GPU Temps from Catalyst Control Center) General Case temps Rear: 18-20°C Mid: 20-21°C Front (HDD/SSD Bays): 14-19°C (Case temps may be a little off as it's from the Kaze master pro fan controller) I have Un-installed EVERY driver for Motherboard, GPU & Soundcard and Re-installed twice. Windows is all up to date. To date i'v tried the following Running Memtest for 24 hrs straight, No errors Running Memtest on each individual RAM modules, No errors Reseated everything except the CPU Cleaned DIMM Sockets and Gold inputs Tested the Graphics cards 1 at a time Re-arranged all the SATA devices to run on Chipset controlled ports Re-installing all drivers OS: Win7 Professional 64bit Motherboard: ASRock X79 Extreme9 CPU: i7 3930k 3.2GHz GPU: Sapphire 7950 OC Edition V2 (2 card Crossfire) RAM: G.Skill Ripjaws Z F3-17000CL11Q-16GBZL 16GB (4x4GB) DDR3 Boot Drive: OCZ Agility 4 128GB Data Drive 1: Western Digital Black 2TB Data Drive 2: Western Digital Black 2TB Data Drive 3: Western Digital Green 3TB Power Supply: Corsair AX1200 Gold

    Read the article

  • Display stretches 4:3 ratios; Adds scrolling to other ratios

    - by Matt
    I have a dual monitor setup. Normally, they both display at 1680x1050. They have been setup this way for about a year. I'm using Windows XP Professional 2003 x64 SP2. Today, out of nowhere, one of the monitors kicked back to a lower resolution. I was not playing with any configuration at the time.. in fact all I had done was close a window (maybe a browser). But the thing is that the resolution is still preserved partially by the fact that the screen will scroll when you move the mouse. So it's like looking through a 1024x768 window into a 1680x1050 world. The monitor itself does not appear to be damaged, because I also have it connected to my netbook (via KVM) and higher resolutions work fine. I tried uninstalling/reinstalling the drivers to no avail. System restore doesn't help either. I'm unsure of the exact ATI card I'm using.. Device Manager lists it as "Radeon X300/X550/X1050". There is no Catalyst Control Center software installed. I tried to install it, but there doesn't seem to be a way to install it by itself ... it forces you to install another driver, which breaks both of my displays, forcing me to go into safe mode and run system restore again. Any ideas? Thanks EDIT: After playing around more, I discovered that the "scrolling" behavior is only present for aspect ratios that are not 4:3. For 4:3 ratios, it just stretches out to fit the wide screen. My monitor's native ratio is 16:9 .. what could be causing it to think it needs to scroll?

    Read the article

  • I must clear my cmos to be able to boot

    - by Fredou
    I have this Asus p7p55d-e pro for about 8 months(got it last July) and for this last 3-4 days I cannot boot without clearing my CMOS what I have is: Seasonic M12D 750W ASUS P7P55D-E Pro Intel Core i5 760 Quad Core Processor Lynnfield LGA1156 XFX GeForce® 8800 GT Alpha Dog 512MB DDR3 Standard (PV-T88P-YDF4) 2x Corsair XMS3 CMX4GX3M2A1600C7 4GB DDR3 2X2GB DDR3-1600 CL 7-8-7-20 I tried to remove all the unnecessary stuff: HD/dvd/pci card/usb cable/etc I tried with only 1 dimm filled, instead of my 4, each one individually it didn't work I tried changing the battery, here goes a few dollars to nowhere, didn't work if I don't reset the CMOS it sometime stock on RAM led, sometime on BOOT DEVICE led, when this happen, it stuck on CPU speed detection when I boot right after the reset, i MUST click on the F2 option (boot with default bios setting) if i go into the bios and save/restart, i have to reset it again when booted, everything is rock solid stable, tried memtest, cpu stress, etc, etc. without issue what should be my next step? trying a new psu? (i need to find one..) doing rma? (i need this mb since it's my only computer...) something else?

    Read the article

< Previous Page | 272 273 274 275 276 277 278 279 280 281 282 283  | Next Page >