Search Results

Search found 23480 results on 940 pages for '32 bit'.

Page 278/940 | < Previous Page | 274 275 276 277 278 279 280 281 282 283 284 285  | Next Page >

  • Strange File-Server I/O Spikes - What Is Causing This?

    - by CruftRemover
    I am currently having a problem with a small Linux server that is providing file-sharing services to four Windows 7 32-bit clients. The server is an AMD PhenomX3 with two Western Digital 10EADS (1TB) drives, attached to a Gigabyte GA-MA770T-UD3 mainboard and running Ubuntu Server 10.04.1 LTS. The client machines are taking an extremely long time to access/transfer data on the file server. Applications often become non-responsive while trying to open files located remotely, or one program attempting to open a file but having to wait will prevent other software from accessing network resources at all. Other examples include one image taking 20 seconds or more to open, and in one instance a user waited 110 seconds for Microsoft Word 2007 to save a document. I had initially thought the problem was network-related, but this appears not to be the case. All cables and switches have been tested (one cable was replaced) for verification. This was additionally confirmed when closing down all client machines and rebooting the server resulted in the hard-drive light staying on solid during the startup process. For the first 15 minutes during boot, logon and after logging on (with no client machines attached), the system displayed a load average of 4 or higher. Symptoms included waiting several minutes for the logon prompt to appear, and then several minutes for the password prompt to appear after typing in a user name. After logon, it also took upwards of 45 seconds for the 'smartctl' man page to appear after the command 'man smartctl' was issued. After 15 minutes of this behaviour, the load average dropped to around 0.02 and the machine behaved normally. I have also considered that the problem is hard-drive-related, however diagnostic programs reveal no drive problems. Western Digital DLG, Spinrite and SMARTUDM show no abnormal characteristics - the drives are in perfect health as far as the hardware is concerned. I have thus far been completely unable to track down the cause of this problem, so any help is greatly appreciated. Requested Information: Output of 'free' hxxp://pastebin.com/mfsJS8HS (stupid spam filter) The command 'hdparm -d /dev/sda1' reports: HDIO_GET_DMA failed: Inappropriate ioctl for device (the BIOS is set to AHCI - I probably should have mentioned that).

    Read the article

  • Viability of Mac OS X 10.9 Time Machine Server in office environment

    - by user197609
    Currently we have about 20 Mac OS 10.9 MacBook Pros (almost all with SSDs) backing up to individual USB drives. I'd like to consolidate these to one drobo thunderbolt drive array attached to a Mac Mini server (running 10.9 server) using time machine server. My question is, will this scale to 20 users? Examples I have seen seem to be 5 or 6 users tops, and this isn't easy for me to test (I'd rather not ask everyone to backup to the array and then switch back to USB drives if it brings our network to its knees). My primary concern is saturating our gigabit network, as time machine backs up every hour for every machine, so there would usually be a couple people backing up at any given time. We also have some people occasionally on our 802.11ac network and not on ethernet (usually connected via 802.11n until people upgrade to newer machines), but most of the time people are connected to our thunderbolt displays which have a gigabit ethernet connection on them. Our network topology is one 32 port gigabit switch with 5 smaller gigabit switches at each desk cluster. The mac mini server is connected directly to the top level switch. Update: Failing information from someone who has done this in practice, I suppose my question is really around how switches work. If three or four people are backing up simultaneously, and then other two (different) users transfer a file between each other, will they be able to transfer the file at gigabit speeds?

    Read the article

  • 2 routers at home- how to connect with VNC?

    - by Charles Leviton
    I have two routers at home. First router is upstairs and is connected to the cable modem. 2nd router is downstairs and acts as "signal booster" for the 1st router. Devices connected to the upstairs router have IP addresses of the form 192.168.1.n Devices connected to the upstairs router have IP addresses of the form 192.168.2.n. I blindly followed instructions from a website to do this set up, just glad it works! Upstairs I have a PC running Win 7 64 bit. Its assigned IP is 192.168.1.7. I have a VNC viewer running on this. Downstairs I have a 2nd PC running Vista 32 Home edition bit that is connected to the 2nd router and has IP Address 192.168.2.114. VNC server is running on this. It's listening on 5900. There is no firewall. When I try to connect to this downstairs PC from upstairs it fails with message "Failed to connect to server". I cannot ping to this either. If I try to connect to this downstairs PC using VNC Viewer from another computer that's connected to the same downstairs router then it works like a charm. So what's the work around if the viewer is on a different "network"? I don't have any problems doing remote desktop connection from the downstairs PC to the upstairs PC even if they are connected to different routers. Router information- Upstairs- ASUS RTN13U, downstairs- DD-WRT v24 RC-5 Thanks! P.S. I posted this on the Ultra VNC forum as well but that doesn't seem to have a lot of activity, so taking the liberty to multipost.

    Read the article

  • Windows 7 - Can't get my TV working as primary display with nVidia 7900GS

    - by Daniel Schaffer
    I just installed Windows 7 Ultimate 64 RTM (from MSDN) on my HTPC, which is connected to a 42" Magnavox LCD TV via component cables to my nVidia 7900GS. Everything was fine through the installation until I went to install the official driver from nVidia. Towards the end of the installation, the TV blinked off and wouldn't come back on. I went and got an LCD monitor and plugged it into a DVI port and the monitor came right up, but was automatically selected as the primary display. Now, if I set the TV to be the primary display, the TV just blanks until I hit escape to cancel the "settings have changed, do you want to keep them" dialog. Any suggestions? Update: I'm able to set the TV as the primary display using the Windows 7 "screen resolution" configuration panel. However, if I try to remove the LCD monitor either by unplugging it or using the configuration, the TV blanks out again. Update 2: This setup was working correctly in Vista Home Premium 32-bit. Update 3: I've uninstalled the nVidia driver and am using the driver that Windows Update installed. As much as this offends my geek sensibilities (must use the "right" driver!!), well, It Works™.

    Read the article

  • USB-to-Serial showing gibberish at 115200 Baud

    - by Mose
    I've got a serious problem which drives me crazy because I tried everything I could think of. First of all, I made a video: http://youtu.be/boghkuq7L_s but please read the following text for more information, not only view the video! When using a USB-to-Serial interface everything works as long as I don't go beyond 57600 Baud. At higher rates I only get giberish like this: év.­b0JNLYÆÿ¿iëd0U²(kßÞb! ú]/xscB!ï¯!BoXûÿ1ïâÖCÿ6ÌAnè*íÌC)º¿BíÞØ.C.@ÆÃwHJÂs "YE:ñ.èFðÌCÊ÷ÞÄ !x H w6@BtbHJ ̪ Ì6ì H¾a¿bH.">îvy®;f<ßBÌ p­L¨fæH­E ­þ¼MBÞI What makes the problem so strange is, I exchanged every component and the problem still presists. I tried differtent OSes (Ubuntu, WinXP, Win7, OSX 10.7) with 32 and 64 Bit. I tried USB-to-Serial interface from FTDI and Prolific. I tried reading the output from my Raspberry PI and from an Asterisk Appliance. I changed the cables and the wiring. Nothing helped. In the video I made a example with a old Notebook with native COM and put the USB-to-Serial to the same connection as "sniffer" (only Rx and GND connected) to make sure the output and everything is ok as one can see on the native port. The voltage is ok. Settings for both are 115200 Baud, 8 Bit with 1 Stop and no flow control. Native is ok. USB is messed up. I used the newest drivers and double checked all connections. I have no idea what is wrong here. As I couldn't find anyone describing problems like this I question my long experiance in computer science and think I'm doing some completly wrong... Please help :-/

    Read the article

  • CPU usage always below 10% in windows server 2008 r2 x64

    - by ???
    I am using a server with windows server 2008 r2 running on it to run my program. The CPU of the server is Intel xeon x5570 2.93GHz with 2 processors, 8 cores per processer. However, I found that the cpu usage is almost always below 10% even I use 32 threads in my program. And I also found that sometimes the cpu usage could reach as high as 93% through the task manager when running my program and at that moment my program has processed over 1000 files per second while normally, it only processed over 50 files per second. However, this does not happen often. I use tools downloaded from the internet to make sure no core sleeps when the server is on, nothing changed. Also, I edited the windows register to make sure that I, as an administer, have no cpu usage limit. But it changed nothing. Is there anyway that I can make full use of my cpu? That is to say that each core runs a thread of my program and the total cpu usage could reach over 50% when I use a reasonable number of threads in my program. Did this happen to anyone of you? And could you help me with this ? Thank you!

    Read the article

  • Migrating ODBC information through a batch file

    - by DeskSide
    I am a desktop support technician currently working on a large scale migration project across multiple sites. I am looking at a way to transfer ODBC entries from Windows XP to Windows 7. If anyone knows of a program or anything prebuilt that already does this, please redirect me. I've already looked but haven't found anything, so I'm trying to build my own. I know enough basic programming to read the work of others and monkey around with something that already exists, but not much else. I have come across a custom batch file written at one site that (among other things) exports ODBC information from the old computer and stores it on a server (labelled as y: through net use at the beginning of the file), then later transfers it from the server to a new computer. The pre-existing code is for Windows XP to XP migrations. Here are the pertinate bits of code: echo Exporting ODBC Information start /wait regedit.exe /e "y:\%username%\odbc.reg" HKEY_LOCAL_MACHINE\SOFTWARE\ODBC\ODBC.INI (and later on) echo Importing ODBC start /wait regedit /s "y:\%username%\odbc.reg" We are now migrating from Windows XP to 7, and this part of the batch file still seems to work for this particular site, where Oracle 8i and 10g are used. I'm looking to use my cut down version of this code at multiple sites, and I'm wondering if the same lines of code will still work for anything other than Oracle. Also, my research on this issue has shown that there are different locations in 64 bit operating systems for 32/64 bit entries, and I'm wondering what effect that would have on the code. Could I copy the same data to both parts of the registry, in hopes of catching everything? Any assistance would be appreciated. Thank you for your time.

    Read the article

  • Updating ASUS BIOS on Windows 7 64bit

    - by joesavage
    I've recently decided that I want to try and utilize my two graphics cards so that I can have a dual monitor setup. Unfortunately Windows only seems to notice my most recent graphics card installation - and so I've been told that I should look into my BIOS and try to enable two graphics cards. I could not find this setting anywhere in my M2N68-AM Plus v0210 BIOS. After some further research I figured that I should perhaps upgrade my BIOS, so I searched and managed to download the latest version (v1804) as a ROM file. However I am having difficulty figuring out how to install it. I've tried using the Asus EZFlash feature built into my BIOS, but when trying to load up a variety of different ROMs that are for my motherboard/BIOS I get the error: Boot block in file is not valid! I'm not totally sure what I should do to fix this, so I'm looking into other methods of upgrading my BIOS - however I can't really find any solutions that seem to work. Asus Update is for 32-bit only, AFUDOS doesn't appear to work on my Windows 7 64-bit system (I think it's supposed to run in DOS or something - but that just sounds confusing since I know nothing about DOS). Could anybody help me with this?

    Read the article

  • Embedded Windows XP

    - by Kyle
    My company acquired a brake press for bending large structural steel plates. We received it second hand and it came with an embedded copy of windows XP. Now for the part that's driving me nuts: plug and play has been turned off, also accessibility options has been disabled. What does this mean for me? Keyboards will not work! Nothing that plugs into a USB port will work and it does not have a CD ROM drive. I have tried to turn on plug and play using the on screen keyboard but it is not there since accessibility options is turned off. I would just get an updated copy of the the embedded OS but they come from Sweden and are extremely expensive. I assume there has got to be a way to get a USB devices to work. We need to get a wifi adapter on it so I can use team viewer and remotely configure it for our needs. Things to keep in mind: There is no keyboard so everything has to be done with the mouse There is no PS2 port for a keyboard just a mouse. Odd. I am 5 states away from this location and have been working with a tech who is physically installing the machine. System 32 seems to be missing A LOT of files, the tech told me there is only 8 folders in there and no other files (I don't even understand how Windows is running like this). If anyone has ANY ideas I would appreciate it, I am unsure where to go from here.

    Read the article

  • What is the risk of introducing non standard image machines to a corporate environment

    - by Troy Hunt
    I’m after some feedback from those in the managed desktop or network security space on the risks of introducing machines that are not built on a standard desktop image into a large corporate environment. This particular context relates to the standard corporate image (32 bit Win XP) in a large multi-national not being suitable for a particular segment of users. In short, I’m looking at what hurdles we might come across by proposing the introduction of machines which are built and maintained by a handful of software developers and not based on the corporate desktop image (proposing 64 bit Win 7). I suspect the barriers are primarily around virus definition updates, the rollout of service packs and patches and the compatibility of existing applications with the newer OS. In terms of viruses and software updates, if machines were using common virus protection software with automated updates and using Windows Update for service packs and patches, is there still a viable risk to the corporate environment? For that matter, are large corporate environments normally vulnerable to the introduction of a machine not based on a standard image? I’m trying to get my head around how real the risk of infection and other adverse events are from machines being plugged into the network. There are multiple scenarios outside of just the example above where this might happen (i.e. a vendor plugging in a machine for internet access during a presentation). Would a large corporate network normally be sufficiently hardened against such innocuous activity? I appreciate the theory as to why policies such as standard desktop images exist, I’m just interested in the actual, practical risk and how much a network should be protected by means other than what is managed on individual PCs.

    Read the article

  • Missing Boot Manager in Vista

    - by Selase
    I am in really deep trouble here and would need advice. A message just pop up on my screen and I had to restart my laptop. Upon restarting the Boot Manager got corrupted. I am running Windows Vista 32 bit by the way. I got onto Google with a friend's PC and found two basic ways of fixing it. The first one that requires Windows to automatically fix it using Startup repair ends up with the error message: Startup REpair cannot repair this computer automatically The second option that requires me to rebuild the BCD scans my system and finds the operating system on drive D:\Windows which I believe should be C:. If I hit Y(yes) for the rebuild process to take place I get the message The required system device cannot be found I then try the second option which requires me to recreate the BCD Store. It ends up with an error message that says: The store export operation has failed. The requested system device cannot be found Proceeding from there is meaningless since the system device cannot be found. I somehow believe the device cannot be found because it's identifying the Windows installation on D: instead of C: but how to change that I have no idea. I don't know how it happens to identify an operating system on D: when there's none there. How do I go about fixing the Boot Manager? I have very important files on my system and can't afford to reinstall Windows. I really need to fix this.

    Read the article

  • Boot stuck at blinking cursor before GRUB - only works via BIOS boot menu

    - by delta1
    I have a new box running Debian Squeeze. Grub is installed on /dev/sda, but when booting up I just get a blinking cursor, before the Grub menu. I can only boot to grub successfully when I choose boot options (during post) and select that specific drive! I have made sure the correct drive is set to boot first in the BIOS. So Grub works, but the system won't boot to that drive automatically? Any ideas on what could cause this? Drives sda/b/c are all 2TB (sda runs the system with b/c as raid device md0) with the following partitions: $ cat /proc/partitions major minor #blocks name 8 0 1953514584 sda 8 1 977 sda1 8 2 9765625 sda2 8 3 6445313 sda3 8 4 1937302627 sda4 8 32 1953514584 sdc 8 16 1953514584 sdb 9 0 1953513424 md0 but # fdisk -l /dev/sda gives WARNING: GPT (GUID Partition Table) detected on '/dev/sda'! The util fdisk doesn't support GPT. Use GNU Parted. Disk /dev/sda: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sda1 1 243202 1953514583+ ee GPT Any insight into this strange behaviour would be greatly appreciated.

    Read the article

  • How to find out which process is hogging the linux server?

    - by user1149518
    We have a RHEL server. Today it suddenly became slow. Symptoms - It was responding slow to ping queries from other server. When I try to login using ssh, it was taking about 10 seconds to login. I was able to resolve the problem by doing some guess work. I killed one process which I thought was culprit. Which resolved the problem. Though I would like to know what's proper approach to detect the culprit in such kind of "slow server" situations. Le me know proper way to resolving such slowness issues and decting the process causing the slowness. These were the conditions when the server was slow - # vmstat 3 3 procs -----------memory---------- ---swap-- -----io---- --system-- -----cpu------ r b swpd free buff cache si so bi bo in cs us sy id wa st 1 1 176 6730868 285052 4899676 0 0 3 4 0 0 1 1 97 1 0 0 0 176 6751576 285064 4899704 0 0 0 115 15307 37171 1 1 96 3 0 0 0 176 6751948 285068 4899700 0 0 0 23 14813 39559 1 1 98 1 0 # top top - 16:38:18 up 150 days, 19:36, 64 users, load average: 1.68, 1.46, 1.44 Tasks: 1287 total, 2 running, 1284 sleeping, 1 stopped, 0 zombie Cpu(s): 1.3%us, 1.7%sy, 0.1%ni, 95.9%id, 0.7%wa, 0.0%hi, 0.2%si, 0.0%st Mem: 16620824k total, 9867124k used, 6753700k free, 287424k buffers Swap: 8193140k total, 176k used, 8192964k free, 4898996k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 26258 khk 34 19 130m 47m 7088 S 11.2 0.3 385:32.42 edm Though I would like to know what's proper approach to detect the culprit in such kind of "slow server" situations. Le me know proper way to resolving such slowness issues and decting the process causing the slowness.

    Read the article

  • Windows Vista freezes

    - by Kakurady
    Windows Vista (32-bit) would randomly freeze on my computer, usually 15-30 minutes after login but can happen just after login. All applications would stop responding and the hard drive will not make any sound, and after a while, the mouse cursor will also stop moving. I dual-boot Ubuntu, and that still works fine. It started with the computer freezing when loading Team Fortress 2. Alt-Tab and Ctrl-Alt-Del have no effect, and the hard drive does not make any sound. I tried to verify the game data using Steam and that freezes the computer too. So I stupidly reinstalled the game. Now the game doesn't freeze when it starts, but instead the whole computer randomly freezes. This computer is a Dell XPS M1530 with a 320GB (298GiB) drive (WDC WD3200BEVT-7) split 5-ways, with Windows and Linux a partition each, one more for Linux swap space, and another two partitions for Dell diagnostic program and factory image and drivers. There was once where the hard drive would make clicking noises all day, and only stopped when I rebooted the computer. Since then, the BIOS diagnostics would fail the drive (for "self-test log contains previous errors") whenever ran. (The on-disk diagnostics cannot be run because I overwrote the MBR with GRUB.) Naturally, I thought the hard drive could be the problem. CHKDSK found one bad sector, but this seems to have no effect. System File Checker found two protected files with wrong hashes, one is some kind of IE manifest, and the other is a tcpmon.ini. Neither of them can be restored because their back up copy also have wrong hashes. Nothing about system failures in the event viewer. What should I do next?

    Read the article

  • Tuning up a MySQL server

    - by NinjaCat
    I inherited a mysql server, and so I've started with running the MySQLTuner.pl script. I am not a MySQL expert but I can see that there is definitely a mess here. I'm not looking to go after every single thing that needs fixing and tuning, but I do want to grab the major, low hanging fruit. Total Memory on the system is: 512MB. Yes, I know it's low, but it's what we have for the time being. Here's what the script had to say: General recommendations: Run OPTIMIZE TABLE to defragment tables for better performance MySQL started within last 24 hours - recommendations may be inaccurate Enable the slow query log to troubleshoot bad queries When making adjustments, make tmp_table_size/max_heap_table_size equal Reduce your SELECT DISTINCT queries without LIMIT clauses Increase table_cache gradually to avoid file descriptor limits Your applications are not closing MySQL connections properly Variables to adjust: query_cache_limit (> 1M, or use smaller result sets) tmp_table_size (> 16M) max_heap_table_size (> 16M) table_cache (> 64) innodb_buffer_pool_size (>= 326M) For the variables that it recommends that I adjust, I don't even see most of them in the mysql.cnf file. [client] port = 3306 socket = /var/run/mysqld/mysqld.sock [mysqld_safe] socket = /var/run/mysqld/mysqld.sock nice = 0 [mysqld] innodb_buffer_pool_size = 220M innodb_flush_log_at_trx_commit = 2 innodb_file_per_table = 1 innodb_thread_concurrency = 32 skip-locking big-tables max_connections = 50 innodb_lock_wait_timeout = 600 slave_transaction_retries = 10 innodb_table_locks = 0 innodb_additional_mem_pool_size = 20M user = mysql socket = /var/run/mysqld/mysqld.sock port = 3306 basedir = /usr datadir = /var/lib/mysql tmpdir = /tmp skip-external-locking bind-address = localhost key_buffer = 16M max_allowed_packet = 16M thread_stack = 192K thread_cache_size = 4 myisam-recover = BACKUP query_cache_limit = 1M query_cache_size = 16M log_error = /var/log/mysql/error.log expire_logs_days = 10 max_binlog_size = 100M skip-locking innodb_file_per_table = 1 big-tables [mysqldump] quick quote-names max_allowed_packet = 16M [mysql] [isamchk] key_buffer = 16M !includedir /etc/mysql/conf.d/

    Read the article

  • Separated virtual networks with same subnet range with 2 interface

    - by Coolpet
    I'm having some problems with routing with the following: I have a server with 2 interfaces. It has 1-1 alias contains the same subnet. the 2 interface is connected to 2 switch, which are separated from each other. Infrastructure: Eth0 192.168.16.2/20 Eth0:eth0 192.168.1.222/20 Eth1 192.168.32.3/20 Eth1:eth1 192.168.1.223/20 I have a PC which has the IP address: 192.168.1.3/24 The problem is the next: If PC is on subnet 1, I can ping it. If PC is on subnet 2, I can't ping it. traceroute shows the route is across 192.168.1.222 ping -I 192.168.1.223 192.168.1.3 is not working on subnet 2. arp entries show the MAC address belonging to the correct interface (eth1 on subnet 2) How can I force the server to look on both interface same ranged subnet for specific IP? It searches only in the first subnet. The routing table has these 2 entries: 192.168.0.0/20 dev eth0 proto kernel scope link src 192.168.1.222 192.168.0.0/20 dev eth1 proto kernel scope link src 192.168.1.223

    Read the article

  • Windows 8 install from USB freezes

    - by Rafael Almeida
    I'm trying to install Windows 8 from an 8GB Kingston Data Traveler. I'm currently using the Windows 7 USB DVD Download Tool to put the iso into the flash drive. It copies the files, but in the end it says it 'had a problem with bootsect' and could not make the flash drive bootable. This seems to be because my current system is Windows 7 32bits, and the bootsect.exe in the ISO is a 64-bit executable. Then I downloaded the 32-bit bootsect.exe and made the drive bootable by running: bootsect /nt60 E: /mbr Then I restarted and managed to boot via the flash drive, but now everything is very slow. It takes about two minutes for the initial black screen with the Windows logo and the spinner go away, then it goes to a purple-ish blank screen that stays on for about five more minutes and then it finally shows a dialog asking for the installation, date/time and keyboard languages. I input then, click "Install Now" and it takes about three more minutes with a "Setup is starting" screen. After that, the PC apparently reboots, the CPU fan speeds up considerably, and there's no video and nothing more happens even after more than ten minutes. What is happening? I already tried using another USB port and even installing from a Samsung G3 Station 2TB external hard disk, but the same thing happens. The file transfer speed to the Kingston drive was about only 3 megabytes per second.

    Read the article

  • Seagate 3TB hard drive loses format information

    - by Victor Bugarin
    I have a Windows 7x64 Ultimate, 6 GB memory, 1 TB HD. 3TB Barracuda XT HDD. The HDD is installed on a StarTech 4 bays external enclosure I had troubles so I converted to a GPT, created 1 partition and formatted as NTFS. The hard drive I can write and read to and from the hard drive but it will become unreadable at some point while I am copying files or after I have copied files to it. I have copied large Bluray movies and diverse video files, I have also copied 32 GB of pictures, and I have copied about 86 thousand music files in different formats. At some point the partition becomes unreadable and I have to format the partition again (all files lost) and I have to start the whole process again. At some point I have been unable to copy large ISO (Bluray movies) file images. I have partitioned the HDD in 2 partitions P1 - 2TB, P2 - 1TB and I have lost every single file in either partition the same way. I reformat the HDD and it seems fine. I have run seatools to check the hard drive and it reports to be OK. What gives?

    Read the article

  • InstallShield or Windows installer corrupted

    - by Bobby S
    Just recently I've been unable to install any software on my Windows 7 machine. Anything that uses InstallShield or the Windows installer will just hang or give a weird error. I noticed there will be many duplicate isbew64.exe processes (like 25) that launch and then just sit there or else a lot of msiexec.exe *32 processes, depending on what I'm trying to install. One piece of software specifically is the Logitech Harmony software. It gives me an *is_string_not_defined* error, saying c:\program files (x86)\:\ the filename, directory name, or volume label syntax is incorrect. The other thing I was trying to install was Battlefield: Bad Company 2, and that just hangs as well, and then just leaves all the Windows installer processes running in the background after I quit the install process. Very odd. I've checked well and googled these issues, it doesn't appear to be any sort of malware issue. I feel like it's related to some kind of corrupted installer application. I've rebooted, deleted the InstallShield folder in program files/common files as some places online suggested but to no avail. I have no idea what to do, any ideas?

    Read the article

  • Almost All Logical Volumes Disappeared - Recovery?

    - by Alex
    We had a hard disc crash of one of two hard discs in a software raid with a LVM on top. The server is running Citrix xenserver. On the hard disk which is still intact, the volume group gets detected well, but only one LV is left. (some hashes replaced by "x") # lvdisplay --- Logical volume --- LV Name /dev/VG_XenStorage-x-x-x-x-408b91acdcae/MGT VG Name VG_XenStorage-x-x-x-x-408b91acdcae LV UUID x-x-x-x-x-x-vQmZ6C LV Write Access read/write LV Status available # open 0 LV Size 4.00 MiB Current LE 1 Segments 1 Allocation inherit Read ahead sectors auto - currently set to 256 Block device 253:0 root@rescue ~ # vgdisplay --- Volume group --- VG Name VG_XenStorage-x-x-x-x-408b91acdcae System ID Format lvm2 Metadata Areas 1 Metadata Sequence No 4 VG Access read/write VG Status resizable MAX LV 0 Cur LV 1 Open LV 0 Max PV 0 Cur PV 1 Act PV 1 VG Size 698.62 GiB PE Size 4.00 MiB Total PE 178848 Alloc PE / Size 1 / 4.00 MiB Free PE / Size 178847 / 698.62 GiB VG UUID x-x-x-x-x-x-53w0kL I could understand if a full physical volume is lost - but why only the logical volumes? Is there any explanation for this? Is there any way to recover the logical volumes? EDIT We are here in a rescue system. The problem is that the whole server does not boot (GRUB error 22) What we are trying to do is to access the root filesystem. But everything was in the LVM. We have only this: (parted) print Model: ATA SAMSUNG HD753LJ (scsi) Disk /dev/sdb: 750GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 32.3kB 750GB 750GB primary boot, lvm And this 750GB LVM volume is exactly what we see on top.

    Read the article

  • Slow, choppy video playback with nVidia 8600GT

    - by user5351
    I have an nVidia 8600GT card (made by EVGA) on a machine with Windows Vista (AMD Athlon X2 processors) and four gigs of ram. It runs pretty good, but I have had some slow/choppy/stuterring video playback issues whenever watching flash videos on Youtube or other sites. The problem is there with both Firefox and IE flash videos, but is maybe worse with Firefox. I also tried Linux with nVidia's binary drivers and it was about the same. I downloaded EVGA precision which allows me to control stuff like the fan and clock speed. The card's temp (in both Vista and Linux) is usually at 66C when idle (not playing a game or watching anything). It goes up a little when watching a video (maybe 68-72C). Any ideas on how to fix this? UPDATE: The issues are both with full screen and embedded flash videos. I have Flash 10.0.32.18 (always make sure I use most recent for security), and the CPU is an AMD Athlon 64 X2 Dual Core Processor 4000+ at 2.11 GHZ. The current GPU driver installed is the most recent GeForce one from last July.

    Read the article

  • linux networking: how to redirect incoming connections from old server to new server?

    - by aliz
    hi I'm in the process of moving my old server to a new server, but i will keep the old server running for database replication and load balancing, etc. each server has a separate internet connection with a static ip, and they are connected through a local Ethernet connection. I've got Ubuntu 8.04 32-bit running on old server and Debian 6.0 64-bit on new one. shorewall firewall is installed on both servers. there are some outdoor devices which are periodically sending data to port 43597 for old server IP address. I can run multiple instances of the network service which is responsible for receiving data from devices on a server but on different ports. here's the question: how can I run the service on new server and have connections coming to old server redirected to it, and new devices can still connect to new server's IP address preferably on the same port and same service? until all devices get updated to send to new server. I've tried a shorewall DNAT rule, but seems like new server's default route should be changed to ethernet connection, which breaks other things. I also found about redir utility, but still haven't tried it. is there any best practice or simple solution for such a scenario, i'm not aware of? thanks in advance.

    Read the article

  • Nvidia RAID 1 Problem. Degraded drives...

    - by Vedat Kursun
    I had a RAID 1 on my system which has a Gigabyte GA 8N SLI motherboard with a Nvidia chipset.(Nvidia Raid IDE ROM BIOS 4.84) When the system was working probably there used to be an icon on the system try which showed my two RAID disks. Bu after my friend accidentally clicked on the "Remove drive safely" icon while trying to disconnect her USB, I noticed that the RAID system wasn't working. After a reboot there was suddenly a failure message during boot screen. When I enter the Nvidia RAID setup utility (F10) I can see that both drives are degraded and that won't change even if I get into them and press R for Rebuild. Other options are only Delete and Exit. When I boot to Windows (XP Pro 32 Bit) I can see both my disks with the same data on each of them but my RAID 1 is broken. It's a relief to see that at least my RAID 1 was active but it's annoying not being able to rebuild it. Is there a way where I can rebuild my RAID 1 without having to delete the array and build it again? Cause I don't want to backup 400 Gigs of data and then recopy it to my drives... (Disks 2 x Seagate ST3500418 AS SATA Drives)

    Read the article

  • Nvidia RAID 1 Problem. Degraded drives...

    - by Vedat Kursun
    I had a RAID 1 on my system which has a Gigabyte GA 8N SLI motherboard with a Nvidia chipset.(Nvidia Raid IDE ROM BIOS 4.84) When the system was working probably there used to be an icon on the system try which showed my two RAID disks. Bu after my friend accidentally clicked on the "Remove drive safely" icon while trying to disconnect her USB, I noticed that the RAID system wasn't working. After a reboot there was suddenly a failure message during boot screen. When I enter the Nvidia RAID setup utility (F10) I can see that both drives are degraded and that won't change even if I get into them and press R for Rebuild. Other options are only Delete and Exit. When I boot to Windows (XP Pro 32 Bit) I can see both my disks with the same data on each of them but my RAID 1 is broken. It's a relief to see that at least my RAID 1 was active but it's annoying not being able to rebuild it. Is there a way where I can rebuild my RAID 1 without having to delete the array and build it again? Cause I don't want to backup 400 Gigs of data and then recopy it to my drives... (Disks 2 x Seagate ST3500418 AS SATA Drives)

    Read the article

  • Windows 7 / TCP/IP network share guide - looking for to resolve failure to mount lacie network drive but works on XP,Linux,Mac.

    - by Rob
    Can anyone advise me of a really good, readable, Windows 7 TCP/IP network share guide, book, or reference. I want this because I cannot mount my Lacie 2big ethernet network drive in Windows 7 (32 bit home), but I can mount it in Windows XP Home 32bit, Ubuntu Linux 10.04 and Apple MacOS X. This drive is being mounted via the accompanying Lacie Ethernet Agent in XP (which I believe uses "Bonjour" protocol), on Mac and Linux it works without further need for software. Another Super User user has the same problem, but no answer: Trouble accessing network drives in Windows 7 I hope my take on the question shows a better willingness to investigate and do some digging - and therefore invite some suggestions to help with this. The drive is detected by Windows 7 (i.e. speech bubble "network drive found") but on trying to open an Explorer window, this remains blank with the Windows busy pointer. I'd prefer not to reinstall Windows 7 to see if that cures the problem, I'd rather understand what is happening/not happening, perhaps even compare differences with Windows XP. Suggestions, please for such guides or even the original problem itself. Update Edit Rewrote question more comprehensively here: Mhttp://superuser.com/questions/304209/looking-for-definitive-answer-to-accessing-a-network-share-via-windows-7-home-and

    Read the article

< Previous Page | 274 275 276 277 278 279 280 281 282 283 284 285  | Next Page >