  • Should use EXT4 or XFS to be able to 'sync'/backup to S3?

    - by Rafa
    It's my first message here, so bear with me... (I have already checked quite a few of the "Related Questions" suggested by the editor) Here's the setup, a brand new dedicated server (8GB RAM, some 140+ GB disk, Raid 1 via HW controller, 15000 RPM) it's a production web server (with MySQL in it, too, not just serving web requests); not a personal desktop computer or similar. Ubuntu Server 64bit 10.04 LTS We have an Amazon EC2+EBS setup with the EBS volume formatted as XFS for easily taking snapshots to S3, via AWS' console. We are now migrating to the dedicated server and I want to be able to backup our data to Amazon's S3. The main reason being the possibility of using the latest snapshot from an EC2 instance in case of hardware failure on the dedicated server. There are two approaches I am thinking of: do a "simple" file-based backup with rsync, dumping the database' and other files, and uploading to amazon via S3 API commands, or to an EC2 instance, or something. do a file-system "freeze" (using XFS) with the usual ebs/ec2 snapshot tool to take part of the file system, take a snapshot, and upload it to Amazon. Here's my question (or series of questions): Can I safely use XFS for the whole system as the main and only format on the dedicated server? If not, is it safe to use EXT4? Or should I use something else? would then be possible to make snapshots of the system to upload to Amazon? Is it possible/feasible/practical to do what I want to do, anyway? any recommendations? When searching around for S3/EBS/XFS, anything relevant to my problem is usually focused on taking snapshots of a XFS system that is already an EBS volume. My intention is to do it in a "real"/metal dedicated server. Update: I just saw this on Wikipedia: XFS does not provide direct support for snapshots, as it expects the snapshot process to be implemented by the volume manager. I had always assumed that I could choose 2 ways of doing snapshots: via LVM or via XFS (without LVM). After reading this, I realize these 2 options are more like it: With XFS: 1) do xfs_freeze; 2) copy the frozen files via, eg, rsync; 3) unfreeze xfs With LVM and XFS: 1) do xfs_freeze; 2) make a binary copy of the frozen fs via lvcreate and related commands; 3) unfreeze xfs; 4) somehow backup the LVM snapshot. Thanks a lot in advance, Let me know if I need to clarify something.

    Read the article

  • Problem with USB drivers (Windows-XP)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • SQL Clustering on Hyper V - is a cluster within a cluster a benefit.

    - by Chris W
    This is a re-hash of a question I asked a while back - after a consultant has come in firing ideas in to other teams in the department the whole issue has been raised again hence I'm looking for more detailed answers. We're intending to set-up a multi-instance SQL Cluster across a number of physical blades which will run a variety of different systems across each SQL instance. In general use there will be one virtual SQL instance running on each VM host. Again, in general operation each VM host will run on a dedicated underlying blade. The set-up should give us lots of flexibility for maintenance of any individual VM or underlying blade with all the SQL instances able to fail over as required. My original plan had been to do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Within the VMs - create a failover cluster and then install SQL Server clustering. The consultant has suggested that we instead do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Create a cluster on the HOST machines which will host all the VMs. Within the VMs - create a failover cluster and then install SQL Server clustering. The big difference is the addition of step 4 whereby we cluster all of the guest VMs as well. The argument is that it improves maintenance further since we have no ties at all between the SQL cluster and physical hardware. We can in theory live migrate the guest VMs around the hosts without affecting the SQL cluster at all so we for routine maintenance physical blades we move the SQL cluster around without interruption and without needing to failover. It sounds like a nice idea but I've not come across anything on the internet where people say they've done this and it works OK. Can I actually do the live migrations of the guests without the SQL Cluster hosted within them getting upset? Does anyone have any experience of this set up, good or bad? Are there some pros and cons that I've not considered? I appreciate that mirroring is also a valuable option to consider - in this case we're favouring clustering since it will do the whole of each instance and we have a good number of databases. Some DBs are for lumbering 3rd party systems that may not even work kindly with mirroring (and my understanding of clustering is that fail overs are completely transparent to the clients). Thanks.

    Read the article

  • Windows 2003 Storage Server Hanging on Large File Transfers

    - by user25272
    In one of our offices we have a Dell PowerVault 745N NAS device which acts as the main file server. Its running 32bit Windows 2003 Storage Server SP2 with 3GB RAM. The server holds around 60 users HOME folders, which are mapped via AD. The office clients are a mix of XP SP3, Vista and Windows 7. Occasionally the server will completely hang when transferring large files. When the hang happens the console becomes unresponsive with only the mouse active and blank wallpaper. Sometimes stopping the copy frees the server, sometimes not. The hanging can last around 20 minutes. During this time other servers also become unresponsive with blank wallpaper at the console. If you do manage to get onto another server the taskbar and run commands are unresponsive. This also transcends to the client computers sometimes with explorer crashing. I'm guessing this is due to the HOME folder mapping. Eventually the NAS server with free up and everything will be back to normal. The server is configured as follows: PERC 4/DC DATA 2 - 12 SCSI HDD - RAID5 SHADOWCOPY 2 SCSI HDD - RAID1 CERC SATA DATA 11 4 SATA HDD - RAID5 OS 4 SATA HDD - RAID5 All the drivers and firmware is up to date. I've been through all the diagnostics with Dell and the hardware has come up clean including full HDD tests on the arrays. The server has NOD32 installed as the AV, but the hanging happens when it is uninstalled. There are no errors in the event log when this happens and we don't have any errors logged on any of our ProCurve switches. DNS is fine on the domain and AD from what I can tell is running happily. There are no DFS or NFS shares setup either. All the shares are standard Windows. I've unchecked the allow the computer to turn off this device to save power box under Power Management on the NIC. "Set Link Speed and Duplex to Auto-negotiate 1000 " Increased Receive Descriptors buffer from 256 to 352 (reserves more CPU resource for handling data) I've run network traces using network monitor and have found the following: 417 8.078125 {SMB:192, NbtSS:25, TCP:24, IPv4:23} 192.168.2.244 192.168.5.35 SMB SMB:R; Nt Create Andx - NT Status: System - Error, Code = (52) STATUS_OBJECT_NAME_NOT_FOUND I've tried different cabling; NICs and switch ports all with the same result. Transferring files from other servers on the domain is fine. All I haven't done is run CHKDSK on the drives to look for any file system errors. On the Vista clients I have also run netsh interface tcp set global autotuning=disabled with no result. Could it be that the server has a faulty drive or that the I/O is too much for it to handle? Any ideas why would the hang cause issues with the other servers on the LAN? Many Thanks.

    Read the article

  • Spotlight Infinite Indexing issue (external data drive)

    - by Manca Weeks
    This is an external drive, formerly a boot drive which is now in use only to access music files (sibelius, audio, midi, live, logic etc.) without transferring the data into a new boot system, partly because of the issue I am about to describe, but mostly because the majority of the data is mainly there for archival purposes. The user is a composer and prominent musician and needs to be able to rehash the data at will. I have tried several things - here is a list: - make complete filesystem clone with antonio diaz's ddrescue - run Disk Warrior on copy, repair whatever errors occurred - wipe out all ACLs on entire drive - set all permissions to the same value - wide open 777 - remove any system data (applications, system files, including hidden files to the best of my knowledge) by selecting only non-system/app data and using Carbon Copy Cloner to put only the data of interest onto a newly formatted drive - transfer data to newly formatted drive folder by folder, resetting the spotlight index in between adding each to observe for issues (interesting here is that no issues occurred except for in Documents folder - when I transferred only the Documents folder to a newly formatted drive on its own - no trouble. It appears almost as thought it may not be the content but the quantity or specific combination of data that results in problems) - use DataRescue to transfer the data to yet another newly formatted drive to expose any missed hidden files Between each of the above steps I stopped Spotlight (search for anything beginning with md in Activity Monitor - All Processes and quitting it), deleted the .Spotlight-V100 directory from the affected drive. Restart Splotlight indexing by adding drive to Spotlight privacy list and removing it. In each case the same issue occurs - Spotlight begins indexing normally (or so it seems), then the index estimated time increases, usually to 4 hours remaining. This is where it gets stuck and continues to predict 4 hours remaining but never finishes. Sometimes I can't eject the drive and have to quit the md.. processes from Activity Monitor to be able to eject the drive without Force Eject. Once I disconnect the drive after the 4 hours remaining situation - if I reattach it, Spotlight forever estimates remaining time and never gets going again. So there it is. It is apparently not a filesystem issue, not a permissions issue and not tied to any particular piece of hardware or protocol (used USB and FW drives). I have tried this on several machines (3 to be precise) and in 10.5.8 and 10.6.5. Simply disabling Spotlight on this volume is not an option because the owner has no clue where things are as the data on the volume dates back to music projects and compositions from 2003 and before. He needs to be able to query for results. Anyone got any ideas? Thanks, M

    Read the article

  • Windows7 issue in mutli- tasking and memory

    - by Nitesh
    I seeming some problem in my windows OS recently, let me first say my system configuration. processor - Intel(R) Core(TM)2 Quad CPU Q8400 @ 2.66 GHz Installed memory (RAM) - 4.00 GB (3.00 GB usable) System type - 32 bit operating system I am using two OS in this system, first one is Windows7 and the other is centOS. Well, I am using this from a long time there was no problem , and all of a sudden since from couple weeks I am facing problems in my Windows7 OS. In windows7 i was nearing using multiple jobs almost every time i log in, there was no problem but now i don't no what happen I am not able to do multiple jobs at same time. For example- 1 I am now not able to listen to music in windows media player and view photo's. All of a sudden the system stops working and does not respond and then respond after 5mins and the music get played where it got stopped after 5 mins. 2 When i start browersing internet it hangs all of sudden and doesn't respond for 2 or 3 mins and gets loading. I mean it just happens for every operation i do in the system. Even now typing was also difficult, it gets hanged very frequently even though i am doing single task. I have never come across this kind of problem before. So the first thing i did was to see the useage of the processor and the memory. Well, i thick the useage of the processor was fine, for single task the useage was some where around 3 to 5%. Well, it was something weird i found in the memory, in spite of no task that i was running it was using somewhere around 34 to 41% of memory. So i opened the task manager and click on resource monitor in performance tab. And in the memory section of the monitoring tool i found the usage of my RAM, it was something like this. Hardware reserved - 1029 MB In Use - 1430 MB Modified - 49 MB Standby - 1566 MB free - 22 MB And i could also see Available 1588 MB Cached 1615 MB Total 3067 MB Installed 4096 MB well, this if all i could find out and i have no idea why my computer is acting so weird all of a sudden and the performance problem is growing day by day and i also don't know if there is problem in Bios, i have let it for default settings from long time. please help me and Thank you in advance for reading this and helping me.

    Read the article

  • Broadcom HT1100 SATA controller not working properly with 1TB drives

    - by Jeff C
    I've been using RHEL distro's for several years and always managed to find the answers until now. I know this is more of a hardware issue, but I've been working on this for over a week and trust Linux and the IT community to help more then HP. I have CentOS 6.3 installed on an HP ProLiant DL145 G3 server with the BroadCom HT1100 IO controller and ServerWorks SATA Controller MMIO BIOS v3.0.0015.6 Firmware. This controller does not support large drives fully. Here's what I've tried and the results; Stock setup - Freezes on the ServerWorks POST screen. Can't even enter CMOS without disconnecting the drives. If I simply disconnect the SATA cables before it gets to the ServerWorks screen and reconnect afterwards I can boot from a CD, USB, PXE fine. However fiddling with cables at ever boot isn't practical. If I enter the BIOS config I can set it to not try booting the drives but leave the controller enabled. This lets me boot normally but the drives are not visible in the OS (live CDs or USB installed). I used method #2 to install and update CentOS. I have the /boot partition on a USB drive (everything else is on the SATA drives in software RAID1) hoping that would work around the issue but I get this Kernel panic - not syncing:Attempted to kill init! Pid: 1, comm: init Not tainted 2.6.32-279.9.1.el6.x86_6 #1 Call Trace: [<ffffffff814fd6ba>] ? panic+0xa0/0x168 [<ffffffff81070c22>] ? do_exit+0x862/0x870 [<ffffffff8117cdb5>] ? fput+0x25/0x30 [<ffffffff81070c88>] ? do_group_exit+0x58/0xd0 [<ffffffff81070d17>] ? sys_exit_group+0x17/0x20 [<ffffffff8100b0f2>] ? system_call_fastpath+0x16/0x1b panic occured, switching back to text console I'm sure it should be possible to talk to the drives without the BIOS boot check since the BIOS doesn't see them in method #2 either, their disconnected when it checks, but Linux sees them fine. If anyone could help figure out how I would greatly appreciate it! The other possible option I've come across is a complex firmware update. Tyan has a few boards on their website with the HT1100 and a ServerWorks v3.0.0015.7 update which says "adds support for TB drives" in the release notes. If someone could help me get the Tyan SATA firmware into the HP ROM file so I could just reflash that would also be very much appreciated. Thanks for any help you guys can offer!

    Read the article

  • Windows Server 2008 - one MAC Address, assign multiple external IP's to VirtualBoxes running as guests on host

    - by Sise
    Couldn't find any help @ google or here. The scenario: Windows Server 2008 Std x64 on i7-975, 12 GB RAM. The server is running in a data centre. One hardware NIC - RealTek PCIe GBE - one MAC Address. The data centre provides us 4 static external IP's. The first is assigned to the host by default of course. I have ordered all 4 IP's, the data centre can assign the available IP's to the physical MAC address of the given NIC only. This means one NIC, one MAC Address, 4 IP's. Everything works fine so far. Now, what I would like to have: Installed VirtualBox with 1-3 guests running, each gets it's own external IP assigned. Each of it should be an standalone Win Server 2008. It looks like the easiest way would be to put the guests into an virtual subnet and routing all data coming to the 2nd till 4th external IP through to this guests using there subnet IP's. I have been through the VirtualBox User Manuel regarding networking. What's not working: I can't use bridged networking without anything else, because the IP's are assigned to the one MAC address only. I can't use NAT networking because it does not allow access from outside or the host to the guest. I do not wanna use port forwarding. Host-only networking itself would not allow internet access, by sharing the default internet connection of the host, internet is granted from the guest to the outside but not from outside or the host to the guest. InternalNetworking is not really an option here. What I have tried is to create an additional MS Loopback adapter for a routed subnet, where the Vbox guests are in, now the idea was to NAT the internet connection to the loopback 'subnet'. But I can't ping the gateway from the guests. By using route command in the command shell or RRAS (static route, NAT) I didn't get there as well. Solutions like the following do work for the one way, but not for the way back: For your situation, it might be best to use the Host-Only adapter for ICS. Go to the preferences of VB itself and select network. There you can change the configuration for the interface. Set the IP address to 192.168.0.1, netmask 255.255.255.0. Disable the DHCP server if it isn't already and that's it. Now the Guest should get an IP from Windows itself and be able to get onto the internet, while you can also access the Host. Slowly I'm pretty stucked with this topic. There is a possibility I've just overlooked something or just didn't getting it by trying, especially using RRAS, but it's kinda hard to find useful howto's or something in the web. Thanks in advance! Best regards, Simon

    Read the article

  • Some services refusing to start on Win 7 machine. What could the root cause be?

    - by BombDefused
    When I check msconfig, there are no services that are blocked from starting up. When I look in services.msc, the problem services have a start up type of 'Automatic', but have a blank space where others will show 'Started'. Attempting to start them manually results in the following pop up error messages. I have no idea what's causing this, looks like some sort of cascade effect from another problem service. It's affecting scheduled tasks, SQL server agent and windows back up services. How can I resolve this? I don't know how to work out what the root cause is. Task Scheduler Service Start Error: "Windows could not start the Task Scheduler service on local computer. 1068: The dependecy service or group failed to start. SQL Server Service Start Error: "The SQL Server Agent service on Local Computer started and then stopped. Some services stop automatically if they are not in use by other services or programs." UPDATE: I've just noticed some other services have a description of "Failed to Read Description. Error Code: 2" They are: NetMsmqActivator, NetPipeActivator, NetTcpActivator, NetTcpPortSharing UPDATE 2: As joeqwerty says the Event Log service does seem to be the root of the problem. This service will not start either. It fails with 'Error 31 - A device attached to the system is not functioning correctly'. I've tried detaching all devices. I've also followed the advice here, where the same problem is described, but with no luck: http://social.technet.microsoft.com/Forums/en/w7itprosecurity/thread/44479c49-55e6-4bd7-b25e-3f2a6497306e Update 3 @ Pacey - The following was a good tip, really clear instruction. However, I found that those reg keys do not exist on my system. "Your Problem might also derive from the UpperFilter or LowerFilter Settings of the CDROM Drive. These are a known cause for Errorcode 31. You can find step-by-step instructions on removing the filters on about.com" I followed the advice through to checking every component in device manager separately, but everything is reported as working correctly!? These services did all work at one point. The hardware set up hasn't changed much. Guess I'm looking at a repair install maybe???!

    Read the article

  • Alienware m15x (older model) BSOD investigation

    - by Crishu
    A frined of mine asked me to help him with an Alienware m15x laptop that had a little service history. It was bought in june 2008, serviced in january 2009 for a random fps drop problem, Alienware returned it saying nothing was wrong. The laptop still had hiccups, but after juggling a few drivers and settings, the fps drops weren't as noticeable. Eventually it died in Sept. 2009. It would not boot up locking itself on a white/gray screen. (i think it was overheating .. clocking in 100 degrees Celsius). So back to Alienware it went. They replaced the GPU and all was fine. Up until these blue screens started showing up. One other thing that was updated was the HDD and a Windows 7 reinstall, in August. From then on it seems to have started its BSOD. Could this be the culprit? Why? 0_o The original Windows was Vista but it was upgraded with a digital download/purchase of Windows 7 Home Premium and activated after installing windows. No errors on the old HDD, just on the latest installation. LE:Due note that now the old HDD is used to see if issues re-occur. So please, I am in need of someone who can interpret these windows dump files: Minidump I may have come to some conflicting conclusions. So if someone can clarify each dump/date and the probable cause/error it had; and a final conclusion or solution, we would be very grateful. Also please consult report for other system info I omitted: same link,code: XRWIVLWG If I missed something or if you have any other questions I'll be happy to answer them. Thank you. Good day. Processor: Intel(R) Core(TM)2 Duo CPU T9300 @ 2.50GHz Network Adapter Properties: Broadcom NetLink (TM) Gigabit Ethernet Intel(R) Wireless WiFi Link 4965AGN Video Adapter Properties: Driver Description NVIDIA GeForce 8800M GTX Driver Date 19.08.2009 Driver Version 8.16.11.8681 Driver Provider NVIDIA INF File oem19.inf Hardware ID PCI\VEN_10DE&DEV_060C&SUBSYS_0770152D&REV_A2 Location Information @system32\DRIVERS\pci.sys,#65536;PCI bus %1, device %2, function %3;(1,0,0) PCI Device NVIDIA GeForce 8800M GTX [NoDB] BIOS String Version 62.92.34.0.8 Installed Drivers nvd3dum (8.16.11.8681), nvwgf2um, nvwgf2um Hard Dik Drive: Model ID ST9120823ASG (**older one 120gb**) Model ID WD32000BEKT (new 320gb with fresh OS)

    Read the article

  • Model M Keyboard inputs incorrect characters after logging in to Fedora

    - by mickburkejnr
    I recently bought a 24 year old IBM Model M keyboard. From what I gather, it'd been left on a shelf for the last 5 years, so you can imagine the amount of dust dirt and crap that was on it. Before cleaning it, I plugged it in to my laptop (running Fedora 17) using a PS/2 to USB adapter. What I found was, while it still works, the keys I press don't correspond to what is displayed on the screen. So for example, when I type S on the keyboard, I get ß display on the screen instead. At the time, I put this down to the adapter not working properly. Since then, I stripped the keys off the keyboard and cleaned the whole thing. It looks like it's just come out of a box! I then plugged it in to my computer (also running Fedora 17) via a standard PS/2 plug. The computer loaded up to the login screen, and I typed in my password. Pressed enter, and I logged straight in to my machine. At this point, I opened up a text editor and started typing some stuff. To my horror, the keystrokes I was entering weren't coming up as intended. What came up instead were characters that would map to the pressed key but only under a different keyboard language setting. I opened up a program to see what keyboard language had been selected, and the correct one for the keyboard was selected (which is UK in my case). I opened up a window that would show what characters mapped to what keys, and I pressed every single key on the keyboard, and every corresponding block representing each key lit up. I went back to the text editor to try again, but I was still getting these random characters. Whats more is that the backspace key would not work, although in the other utility it would flash when pressed. What I know is that at the login screen the keyboard must have entered the correct characters, otherwise I wouldn't have been able to log in. Further more, keys that don't respond while using a text editor as sending signals to the computer, as illustrated in that keyboard utility. The question is why random characters are displayed when they really shouldn't be? Would this be a hardware fault or a software issue?

    Read the article

  • What are the most likely bottlenecks determining the performance of CamStudio screen recording?

    - by Steve314
    When doing screen recording, I can get a frame rate of maybe 15 frames per second for the full screen on my 1080p monitor using the XVID codec. I can increase the speed a bit by recording a region, changing screen modes, and tweaking other settings, but I'm curious what hardware upgrades might give me the biggest bang for my buck. My PC is budget, but modern... Athlon 2 X4 645 (3.1GHz, quad core, limited cache) processor. 4GB single channel DDR3 1066 RAM. ASRock motherboard with NVidia GeForce 7025/nForce 630a Chipset. ATI Radeon HD 5450 graphics card - 512MB on board, not configured to steal system RAM. I dual-boot Windows XP and Windows 7. For the moment, XP is my bigger performance concern as it's still my getting-things-done O/S as opposed to my browser-host O/S. My goal is to make a few programming-related tutorials. For a lot of that I don't need screen recording - I can make up some slides, record audio with the PC switched off, yada yada. When I do need screen recording, I'll mostly be recording Notepad++, Visual Studio or a command prompt. Occasionally, I may be recording some kind of graphics or diagram program and using my pre-Bamboo cheap Wacom tablet - I have the CS2 versions of Photoshop and Illustrator, but I'd much more likely be using Microsoft Paint. Basically, what I'll be recording won't be making huge demands on the machine - but recording a fair number of pixels (720p preferred) will be useful. What's particularly wierd - not so long ago I still had a five-year-old Pentium 4 based PC. And (with the same 1080p monitor) it could record at not far from the same frame rate. So clearly the performance issues are more subtle than just throw-money-at-it. My first guess would be that the main bottleneck is the bandwidth for transferring data to/from the graphics card. Is that likely to be correct? In support of that, see this [Radeon HD 5450 review][1] - the memory bandwidth is only 12.8 GB/s. If you can't get data out of graphics memory quickly, you can't transfer it back to the system memory quickly. Apparently, that's slower than some top-end cards in 2002.

    Read the article

  • SMBfs mounting OK, listing OK, Read KO, smbclient OK

    - by Kwaio
    I've tried to make the title the most meaningfull I could but it still looks ugly. The premises. We are using RHEL3-U8 as OS on most servers here, don't ask me why or suggest to upgrade, it's not on today's schedule. That means kernel used is 2.4.21 I have no access to the remote server, but I know it is a netApp NAS rack. $> smbclient --version Version 3.0.9-1.3E.9 Here is the /etc/fstab line : //NASHOSTNAME/share /mnt/mydir smbfs ro,uid=123,gid=123,workgroup=XXXX,credentials=/somefile 0 0 Here is the following mount output line //NASHOSTNAME/share on /mnt/mydir type smbfs (0) The symptoms. I can list the share without problems, even cd in there. The issue appears if I try to read any file : $> cat /mnt/mydir/fileX.txt cat: /mnt/mydir/fileX.txt: Input/output error In the system logs (/var/log/kernel for example) the following errors appear. Jul 30 15:40:02 hostname kernel: smb_errno: class ERRHRD, code 31 from command 0x2 Jul 30 15:40:02 hostname kernel: smb_errno: class ERRHRD, code 31 from command 0x2 Jul 30 15:40:02 hostname kernel: smb_open: fileX.txt open failed, result=-5 Jul 30 15:40:02 hostname kernel: smb_errno: class ERRHRD, code 31 from command 0x2 Jul 30 15:40:02 hostname kernel: smb_errno: class ERRHRD, code 31 from command 0x2 Jul 30 15:40:02 hostname kernel: smb_open: fileX.txt open failed, result=-5 Jul 30 15:40:02 hostname kernel: smb_readpage_sync: fileX.txt open failed, error=-5 The ERRHRD code 0x001F error is "General hardware failure" although it seems samba sometimes uses it for a different purpose, see http://www.ubiqx.org/cifs/SMB.html [Strange behaviour Alert] Additionnal informations : There is another SMB mountpoint on the system pointing to a (linux) host using samba and this one works. What I have tried. I have tried adding debug=4 to the mounting options and remounting the share and the logs still look the same. I have tried to mount the share with smbclient and I am able to fetch files with the get command. Both targets are in the same subnet, so network problem should be out, even if the LAN goes through a VPN with optimizers, MTU has already been decreased to 1450. I can also mount the share through NFS but then the files are all root.root 700 and I need to read them with another user...

    Read the article

  • ZFS Recover from Faulted Pool State

    - by nickv2002
    I have a six disk ZFS raidz1 pool and had a recent failure requiring a disk replacement. No problem normally, but this time my server hardware died before I could do the replacement (but after and unrelated to the drive failure as far as I can tell). I was able to get another machine from a friend to rebuild the system, but in the process of moving my drives over I had to swap their cables around a bunch until I got the right configuration where the remaining 5 good disks were seen as online. This process seems to have generated some checksum errors for the pool/raidz. I have the 5 remaining drives set up now and a good drive installed and ready to take the place of the drive that died. However, since my pool state is FAULTED I'm unable to do the replacement. root@zfs:~# zpool replace tank 1298243857915644462 /dev/sdb cannot open 'tank': pool is unavailable Is there any way to recover from this error? I would think that having 5 of the 6 drives online would be enough to rebuild the right data, but that doesn't seem to be enough now. Here's the status log of my pool: root@zfs:~# zpool status tank pool: tank state: FAULTED status: One or more devices could not be used because the label is missing or invalid. There are insufficient replicas for the pool to continue functioning. action: Destroy and re-create the pool from a backup source. see: http://zfsonlinux.org/msg/ZFS-8000-5E scan: none requested config: NAME STATE READ WRITE CKSUM tank FAULTED 0 0 1 corrupted data raidz1-0 ONLINE 0 0 8 sdd ONLINE 0 0 0 sdf ONLINE 0 0 0 sdh ONLINE 0 0 0 1298243857915644462 UNAVAIL 0 0 0 was /dev/sdb1 sde ONLINE 0 0 0 sdg ONLINE 0 0 0 Update (10/31): I tried to export and re-import the array a few times over the past week and wasn't successful. First I tried: zpool import -f -R /tank -N -o readonly=on -F tank That produced this error immediately: cannot import 'tank': I/O error Destroy and re-create the pool from a backup source. I added the '-X' option to the above command to try to make it check the transaction log. I let that run for about 48 hours before giving up because it had completely locked up my machine (I was unable to log in locally or via the network). Now I'm trying a simple zpool import tank command and that seems to run for a while with no output. I'll leave it running overnight to see if it outputs anything.

    Read the article

  • Mouse Error Code 24. Windows 7

    - by Cj.
    I've had the same mouse for a while, and it's been working fine until one day, it started giving me a message about a device not working properly. I tried updating the drivers, and re-installing, I even deleted old drivers in case my computer should be a little confused. It never made a difference, and my mouse seemed to be working just fine despite getting the permanent error in my device manager, I looked it up several times online, but I never found anything I could actually use, when I go to official websites, I always get the same response "plug in so so into a different place - drivers - install silverlight before you can watch this tutorial, try it on a different machine". so I gave up on that. But now is where I have a real problem, lately, my little strange error evolved into a fullblown Error 24, and my mouse is starting to turn on and off randomely, especially when it is being used, but I do hear it go "badum..dadum" when I'm off doing something else. when I looked up error code 24, I really didn't find much other than it meaning: Code 24 This device is not present, is not working properly, or does not have all its drivers installed. (Code 24) Cause The device is installed incorrectly. The problem could be a hardware failure, or a new driver might be needed. Devices stay in this state if they have been prepared for removal. After you remove the device, this error disappears. But, I have tried uninstalling the device entirely several times, and it'll go right back to its previous state with error 24, and turning on and off randomely. what do I do? I cannot afford taking it to a repair place, I can't really afford a new mouse either, I refuse to buy cheap ones as I am a gamer, in need of more than 3 buttons, and a good grip is important. Could there possibly be some confusion in the registry? I do remember having gotten some early problems after I converted my vista to windows7. But I hardly dare going in there unless I'm 100% certain of what I'm going for, and I can honestly say I am at a loss here. Edit: it is a USB mouse we're talking about here. MX™518 Optical Gaming Mouse (logitech) Edit2: I am seeing no rupture, so it must be on the inside of my mouse, or inside the rubber, protecting the cable, that would be really inconvenient to search for

    Read the article

  • Holding off Windows 2000/3 Server in Shutdown

    - by user1668993
    We have a C# VS2010 application running on a Windows 2000 Server box (there is also a Windows 2003 Server box) as pretty much the only application running. We remove power from the box. There is a short duration battery (maybe 3 minutes of power) which then waits 10 seconds and then decides things are coming down and notifies Windows that it needs to shut down. Windows sends a CTRL_SHUTDOWN_EVENT event to the application which fields it and tries to keep Windows from going down for a while to let another computer which communicates with this one time to do some file work on the first computer. It does this by a timing loop and after the loop is over, it exits gracefully and the computer shuts down. Nice plan but it doesn't work. The application gets to maybe 20 seconds and the application is forcibly killed by Windows and Windows shuts down. At 90 seconds, the hardware firmware running the battery turns off power to the computer. I have tried searching to find out how to hold off Windows for a bit of time. I tried creating (it wasn't there) the HKEY_LOCAL_MACHINE subtree: \SYSTEM\CurrentControlSet\Control\WaitToKillAppTimeout registry key to 60000 but though it seemed to keep the popup from happening, Windows itself died at about the same amount of time -- we think without having the opportunity to shut itself down gracefully. Maybe the registry key worked but wasn't enough. Basically I have an "ill-mannered" application which is refusing to shut down (for the best of reasons) and without the registry key thing, Windows eventually shuts it down anyway and then shuts itself down. With the registry change, we think what is happening is that Windows doesn't shut down the application but Windows itself is killed suddenly without shutting down but power is still not pulled for about another minute, and then power is pulled. So maybe we have layers here. First there is how long the application tries to stay open. Then there is how long Windows is prepared to allow it to stay open. Then there is ... something... which kills windows. Then there is the power loss. Anyone have any ideas how we can get windows to stay open and in operation say to 70 seconds instead of about 20? Is our registry key right, but not enough? Is there some additional key we need to set to determine how long after windows is notified of a shutdown before it just kills itself? Thanks in advance.

    Read the article

  • Possible HDD malfunction. Need help in diagnosing

    - by Protheus
    Today when using my PC as I did for almost 4 years I experienced the following: during opening new tab in Opera browser screen froze. Music (AIMP 3) continued to play for about 5 minutes and then stopped too. I tried Ctrl+Alt+Del, but win7 lock screen didn't appear. Caps\Scroll or Num locks didn't switch diodes on keyboard. I rebooted my PC and saw that BIOS suggests me to enter it's settings or load by default. I chose default. It don't see proper boot device (old faitful "insert proper boot" something). After second reboot it said that there is no ExpressGate installed (which i turned off in BIOS years ago). I went into BIOS setting to turn off ExpressGate and see configs: time was not set off, all hard drives present, temp and O.C. settings are nominal (no O.C.) I've inserted my Win7 install disk to try recovery. It did load awfully long (about few minutes) and didn't see current installation. PC was utilized in 24/7 mode for almost all these years. Hardware configuration: ASUS P5Q WS Core 2 Quad Q9300 (2.5GHz no O.C.) MSI geForce GTX 460 4x2 Gb GeIL EVO 2 (AFAIR) Seagate something 750Gb (4 years as system HDD 24/7) WD 1Tb (for random stuff, 5 y.o.) Hitachi 500Gb (for even more random stuff, 6 y.o.) NEC DVDRW (ALL DISKS ARE SATA) Cooler Master Silent Pro 700W Software: Windows 7 AND Kubuntu on the same drive with GRUB loader. Sorry I can't remember HDDs and can't see them right now, but I think their models aren't relevant anyway. My idea is that due to some system error or hard drive glitch i've wrecked my primary HDD's MBR. Nevertheless I don't exclude the possibility of other failure. May it's be that motherboard or it's SATA controller? Doubt it, because all drives are seen in BIOS and I could load from DVD. Maybe GRUB got bugged somehow, although I don't see how it's possible from Windows. But I did install KUbuntu from Windows (i wasn't myself then), maybe GRUB did write itself in some windows partition and got rewriteen in process? Right now I am at work with my flash drive with me and I need some advice how to fix MBR or to hear if it's not MBR. I'm going to buy new HDD (Hitachi 7k2000) because I think that my current HDD is compromised and it's unsafe to use it as system drive, especially 24/7.

    Read the article

  • Have a server, need to figure out a method of backup

    - by PolishHurricane
    My company has an older Dell 2650 server running ArchLinux x64: http://www.dell.com/downloads/global/products/pedge/en/2650_specs.pdf (2 x 2.4GHz Intel Xeon w/around 3287 RAM according to "free -m") We use it to host our internal company site and to post some information from our orders to and we'd like the ability to keep it up as much as possible. What we require: - It needs to always be functional from 8am to 4pm for our data entry person to use it and others to do other things required on it. - If it goes down, we need a quick way to get the machine running again. - If it goes down, we would like to have the data backed up. Some of the major problems include: - The servers old and it may have memory issues - We don't know when one of the hard drives could fail - Our power goes out here once in a while We have a battery backup, but that's pretty much it and it's not for long term. If the server does go down, we have another system in place to store order information that comes in while it's down and repost it when it's back, but we need it up during the day. So we're wondering, what should we get for options? These are the things we thought of, sort of: Setup RAID 1, but that would involve wiping everything right? If we do that, how would we transfer the data over without messing up the server? We could buy an extra server or 2 off eBay for $100, the same model, is that practical or should we get something else? Should we buy a PC or another better server and host off that because it is if anything easier to exchange parts? Should we keep extra parts handy incase it implodes? Should we buy/use backup software? We hear drobo's are cool, but suck. Perhaps there is a software solution to this problem that backs up to another machine or gets us up and running again quickly. Also, if we are to purchase hardware, what is decent? Does anybody know of one for ArchLinux/Linux? We both know a ton about computers but we're kind of unsure what step to take with this, especially with this type of server. Thanks

    Read the article

  • Laptops on Windows Domain sometimes have problems accessing internet when off-site

    - by FSUScoot
    Hi all-- We've had this problem for a long time. When users travel, sometimes they can't get internet access from a wired or wireless connection. Here are a couple examples: 1) A user goes to a hotel and tries to access the wireless in their room. They can connect to the access point. They open a web browser and they can't get re-directed to the hotel's login page. Because they can't log in, there's no internet access. 2) A user goes to another laboratory/university and tries to access the wired network. They connect, link is fine, PC gets IP from DHCP but no internet access. There's no login page to be re-directed to. It should just "work". What I've found is that it's a DNS issue. Because the computer is on a Windows Domain, it seems it MUST use our DNS servers. Even if you connect to an outside network and do an ipconfig /all, it looks like everything is ok. It'll even show their DNS servers listed in the config. The computer just won't use the other network's DNS server. I found a reg key that keeps our DNS servers listed and it seems that they take priority every time: HKLM\SOFTWARE\Policies\Microsoft\Windows NT\DNSClient All the values under that key are for our AD domain. NameServer and Searchlist never change. What I've found is if the user edits the NameServer string and puts the DNS server of the network they're on, everything works just fine. They get re-directed to the hotel's correct login page or their internet access starts working. It's only a problem if the network they're on blocks outside DNS or a hotel that uses an internal name in their front page redirection that only their DNS server knows about, i.e., not public. If the re-direct page starts with an IP, like 10.10.10.10, it'll work just fine. Obviously this isn't a fix for everyone. Most of my users are pretty knowledgeable so it’s easy for me to walk them through or send them a .reg file that they can edit and run. This problem isn't limited to Windows 7. It was like this with XP as well. It's not hardware related. The problem exists on both wired and wireless, Intel or Broadcom, laptops or desktops. Anyone else have this problem? Is there a GPO I can change that I missed? Got a good work-around for this? Thanks for any help!

    Read the article

  • Windows 2003 Server Caching

    - by pablomedok
    We're experiencing almost everyday table index corruption on Windows Server 2003. We are running an old application which uses DBF/CDX tables. Everything was fine for ages, but 6 months after we've installed Advantage Database Server (which allows access to some tables to our website) we started to get index corruption problems. And we don't know whom to blame. We've tried to exclude all possible causes of this corruption. Now all users work in terminal mode - so no network problems can cause that, OpLocks also can't be a reason. We changed hardware, network cards, switches, reainstalled Server and even moved to new dedicated server. The only thing we can't exclude is ADS - because it should be working. Is that possible that local read/write caching that causes that problem? E.g. one user or process uses cached data, later another user/process changes it, and later the first user changes it again without knowing about the first change. Is it possible theoretically? Is it possible that this problem is caused by imporper file server or caching settings? Is it possible that normal users use non-cached data and ADS is using cached data? Or vice versa? Is it possible that each terminal user has its own cache? Or maybe the problem is about RAID caching somehow interfering with Windows Server caching? Or maybe there are some special settings for Windows Server for working with DBF tables that are being written simultaneously by several terminal users? Maybe there is a way to turn off caching for some certain files to check it? Sometimes we get index crash twice a day, sometimes everything is fine for 5 days in a row. Today only one user was working in the evening with the database (usually there are 30-50 users are working simultaneously on working hours). So it's almost zero load on server. , Syncronization with website is performed every 5 minutes during work hours and every 15 minutes in the evening and on weekend. We've done file access auditing and it shows that during website syncroniztions ADS server opens the table and index files for ReadEA and WriteEA though it performs only SELECT queries. ADS does UPDATE/INSERT queries but less freqently - not during regular synchronizations, but only when an order is placed by website visitor). Please help me. We are struggling with this problem for almost a year and still can't find any pattern or any clue about this problem. Here is my previous qestion about this issue on DBA: http://dba.stackexchange.com/questions/8646/foxpro-dbf-index-corruption

    Read the article

  • If Nvidia Shield can stream a game via wifi, why can I not do the same via ethernet to any other PC?

    - by Enigma
    I think it absurd that a wireless game streaming solution is the *first to hit the market when a 1000mbps+ Ethernet connection would accomplish the same feat with roughly 6x the available bandwidth. I can only assume that there must be some reason behind this or a limitation preventing this, but what? 150mbps wifi is in no way superior to a 1000mbps LAN connection aside from well wireless mobility. Not only that but I have a secondary laptop and desktop which should by hardware comparison completely outperform anything the Tegra in the Nvidia Shield can do. Is this all just a marketing scheme to force people to buy the shield for the streaming benefit? Chief among these is that NVIDIA’s Shield handheld game console will be getting a microconsole-like mode, dubbed “Shield Console Mode”, that will allow the handheld to be converted into a more traditional TV-connected console. In console mode Shield can be controlled with a Bluetooth controller, and in accordance with the higher resolution of TVs will accept 1080p game streaming from a suitably equipped PC, versus 720p in handheld mode. With that said 1080p streaming will require additional bandwidth, and while 720p can be done over WiFi NVIDIA will be requiring a hardline GigE connection for 1080p streaming (note that Shield doesn’t have Ethernet, so this is presumably being done over USB). Streaming aside, in console mode Shield will also support its traditional local gaming/application functionality. - http://www.anandtech.com/show/7435/nvidia-consolidates-game-streaming-tech-under-gamestream-brand-announces-shield-console-mode ^ This is not acceptable for me for a number of reasons not to mention the ridiculousness of having a little screen+controller unit sitting there while using a secondary controller and screen instead. That kind of redundant absurdity exemplifies how wrong of a solution that is. They need a second product for this solution without the screen or controller for it to make sense... at which point your just buying a little computer that does what most other larger computers do better. All that is required, by my understanding, is the ability to decode H.264 video compression and transmit control/feedback so by any logical comparison, one (Nvidia especially) should have no difficulty in creating an application for PC's (win32/64 environment) that does the exact same thing their android app does. I have 2 video cards capable of streaming (encoding) H.264 so by right they must be capable of decoding it I would think. I haven't found anything stating plans to allow non-shield owners to do this. Can a third party create this software or does it hinge on some limitation that only Nvidia can overcome? (*) - perhaps this isn't the first but afaik it is the first complete package.

    Read the article

  • How should we serve files in a small bioinformatics cluster?

    - by cespinoza
    We have a small cluster of six ubuntu servers. We run bioinformatics analyses on these clusters. Each analysis takes about 24 hours to complete, each core i7 server can handle 2 at a time, takes as input about 5GB data and outputs about 10-25GB of data. We run dozens of these a week. The software is a hodgepodge of custom perl scripts and 3rd party sequence alignment software written in C/C++. Currently, files are served from two of the compute nodes (yes, we're using compute nodes as file servers)-- each node has 5 1TB sata drives mounted separately (no raid) and is pooled via glusterfs 2.0.1. They each have as 3 bonded intel ethernet pci gigabit ethernet cards, attached to a d-link DGS-1224T switch ($300 24 port consumer-level). We are not currently using jumbo frames (not sure why, actually). The two file-serving compute nodes are then mirrored via glusterfs. Each of the four other nodes mounts the files via glusterfs. The files are all large (4gb+), and are stored as bare files (no database/etc) if that matters. As you can imagine, this is a bit of a mess that grew organically without forethought and we want to improve it now that we're running out of space. Our analyses are I/O intensive and it is a bottle neck-- we're only getting 140mB/sec between the two fileservers, maybe 50mb/sec from the clients (which only have single NICs). We have a flexible budget which I can probably get up $5k or so. How should we spend our budget? We need at least 10TB of storage fast enough to serve all nodes. How fast/big does the cpu/memory of such a file server have to be? Should we use NFS, ATA over Ethernet, iSCSI, Glusterfs, or something else? Should we buy two or more servers and create some sort of storage cluster, or is 1 server enough for such a small number of nodes? Should we invest in faster NICs (say, PCI-express cards with multiple connectors)? The switch? Should we use raid, if so, hardware or software? and which raid (5, 6, 10, etc)? Any ideas appreciated. We're biologists, not IT gurus.

    Read the article

  • How to reliably map vSphere disks <-> Linux devices

    - by brianmcgee
    Task at hand After a virtual disk has been added to a Linux VM on vSphere 5, we need to identify the disks in order to automate the LVM storage provision. The virtual disks may reside on different datastores (e.g. sas or flash) and although they may be of the same size, their speed may vary. So I need a method to map the vSphere disks to Linux devices. Ideas Through the vSphere API, I am able to get the device info: Data Object Type: VirtualDiskFlatVer2BackingInfo Parent Managed Object ID: vm-230 Property Path: config.hardware.device[2000].backing Properties Name Type Value ChangeId string Unset contentId string "d58ec8c12486ea55c6f6d913642e1801" datastore ManagedObjectReference:Datastore datastore-216 (W5-CFAS012-Hybrid-CL20-004) deltaDiskFormat string "redoLogFormat" deltaGrainSize int Unset digestEnabled boolean false diskMode string "persistent" dynamicProperty DynamicProperty[] Unset dynamicType string Unset eagerlyScrub boolean Unset fileName string "[W5-CFAS012-Hybrid-CL20-004] l****9-000001.vmdk" parent VirtualDiskFlatVer2BackingInfo parent split boolean false thinProvisioned boolean false uuid string "6000C295-ab45-704e-9497-b25d2ba8dc00" writeThrough boolean false And on Linux I may read the uuid strings: [root@lx***** ~]# lsscsi -t [1:0:0:0] cd/dvd ata: /dev/sr0 [2:0:0:0] disk sas:0x5000c295ab45704e /dev/sda [3:0:0:0] disk sas:0x5000c2932dfa693f /dev/sdb [3:0:1:0] disk sas:0x5000c29dcd64314a /dev/sdc As you can see, the uuid string of disk /dev/sda looks somehow familiar to the string that is visible in the VMware API. Only the first hex digit is different (5 vs. 6) and it is only present to the third hyphen. So this looks promising... Alternative idea Select disks by controller. But is it reliable that the ascending SCSI Id also matches the next vSphere virtual disk? What happens if I add another DVD-ROM drive / USB Thumb drive? This will probably introduce new SCSI devices in between. Thats the cause why I think I will discard this idea. Questions Does someone know an easier method to map vSphere disks and Linux devices? Can someone explain the differences in the uuid strings? (I think this has something to do with SAS adressing initiator and target... WWN like...) May I reliably map devices by using those uuid strings? How about SCSI virtual disks? There is no uuid visible then... This task seems to be so obvious. Why doesn't Vmware think about this and simply add a way to query the disk mapping via Vmware Tools?

    Read the article

  • Can not get sound over hdmi in kubuntu 9.10

    - by user32509
    I have used a hdmi cable to connect my lcd (which is connected with my speakers) with my nvida 275 gtx grafic card. I can not get the sound output to work. The hardware itself is working probably - I tested it under windows. Currently I am running Kubuntu 9.10 64 with Nvidia 190.53. The sound output worked fine before I installed the hdmi connection. (German output - i can change it, if you tell me how :)) aplay -l **** Liste von PLAYBACK Geräten **** Karte 0: Intel [HDA Intel], Gerät 0: ALC889A Analog [ALC889A Analog] Untergeordnete Geräte: 1/1 Untergeordnetes Gerät '0: subdevice #0 Karte 0: Intel [HDA Intel], Gerät 1: ALC889A Digital [ALC889A Digital] Untergeordnete Geräte: 1/1 Untergeordnetes Gerät '0: subdevice #0 aplay -L front:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog Front speakers surround40:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 4.0 Surround output to Front and Rear speakers surround41:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 4.1 Surround output to Front, Rear and Subwoofer speakers surround50:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 5.0 Surround output to Front, Center and Rear speakers surround51:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 5.1 Surround output to Front, Center, Rear and Subwoofer speakers surround71:CARD=Intel,DEV=0 HDA Intel, ALC889A Analog 7.1 Surround output to Front, Center, Side, Rear and Woofer speakers iec958:CARD=Intel,DEV=0 HDA Intel, ALC889A Digital IEC958 (S/PDIF) Digital Audio Output null Discard all samples (playback) or generate zero samples (capture) pulse Playback/recording through the PulseAudio sound server And i disabled mute in kmix an all channels :) Edit: lspci -v ... 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 02) Subsystem: Giga-byte Technology Device a022 Flags: bus master, fast devsel, latency 0, IRQ 22 Memory at ea400000 (64-bit, non-prefetchable) [size=16K] Capabilities: [50] Power Management version 2 Capabilities: [60] Message Signalled Interrupts: Mask- 64bit+ Queue=0/0 Enable- Capabilities: [70] Express Root Complex Integrated Endpoint, MSI 00 Capabilities: [100] Virtual Channel <?> Capabilities: [130] Root Complex Link <?> Kernel driver in use: HDA Intel Kernel modules: snd-hda-intel ... cat /proc/asound/version Advanced Linux Sound Architecture Driver Version 1.0.20. lsmod | grep snd_hda_intel snd_hda_intel 31880 2 snd_hda_codec 87584 2 snd_hda_codec_realtek,snd_hda_intel snd_pcm 93160 3 snd_hda_intel,snd_hda_codec,snd_pcm_oss snd 77096 16 snd_hda_codec_realtek,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm_oss,snd_mixer_oss,snd_pcm,snd_seq_oss,snd_rawmidi,snd_seq,snd_timer,snd_seq_device snd_page_alloc 10928 2 snd_hda_intel,snd_pcm I think I am missing the something-hdmi module? Is there such a thing?

    Read the article

  • Tips for maximizing Nginx requests/sec?

    - by linkedlinked
    I'm building an analytics package, and project requirements state that I need to support 1 billion hits per day. Yep, "billion". In other words, no less than 12,000 hits per second sustained, and preferably some room to burst. I know I'll need multiple servers for this, but I'm trying to get maximum performance out of each node before "throwing more hardware at it". Right now, I have the hits-tracking portion completed, and well optimized. I pretty much just save the requests straight into Redis (for later processing with Hadoop). The application is Python/Django with a gunicorn for the gateway. My 2GB Ubuntu 10.04 Rackspace server (not a production machine) can serve about 1200 static files per second (benchmarked using Apache AB against a single static asset). To compare, if I swap out the static file link with my tracking link, I still get about 600 requests per second -- I think this means my tracker is well optimized, because it's only a factor of 2 slower than serving static assets. However, when I benchmark with millions of hits, I notice a few things -- No disk usage -- this is expected, because I've turned off all Nginx logs, and my custom code doesn't do anything but save the request details into Redis. Non-constant memory usage -- Presumably due to Redis' memory managing, my memory usage will gradually climb up and then drop back down, but it's never once been my bottleneck. System load hovers around 2-4, the system is still responsive during even my heaviest benchmarks, and I can still manually view http://mysite.com/tracking/pixel with little visible delay while my (other) server performs 600 requests per second. If I run a short test, say 50,000 hits (takes about 2m), I get a steady, reliable 600 requests per second. If I run a longer test (tried up to 3.5m so far), my r/s degrades to about 250. My questions -- a. Does it look like I'm maxing out this server yet? Is 1,200/s static files nginx performance comparable to what others have experienced? b. Are there common nginx tunings for such high-volume applications? I have worker threads set to 64, and gunicorn worker threads set to 8, but tweaking these values doesn't seem to help or harm me much. c. Are there any linux-level settings that could be limiting my incoming connections? d. What could cause my performance to degrade to 250r/s on long-running tests? Again, the memory is not maxing out during these tests, and HDD use is nil. Thanks in advance, all :)