Search Results

Search found 16188 results on 648 pages for 'connection broker'.

Page 308/648 | < Previous Page | 304 305 306 307 308 309 310 311 312 313 314 315  | Next Page >

  • Exploring packages in code

    In my previous post Searching for tasks with code you can see how to explore the control flow side of packages, drilling down through containers, task, and event handlers, but it didn’t cover the data flow. I recently saw a post on the MSDN forum asking how to edit an existing package programmatically, and the sticking point was how to find the the data flow and the components inside. This post builds on some of the previous code and shows how you can explore all objects inside a package. I took the sample Task Search application I’d written previously, and came up with a totally pointless little console application that just walks through the package and writes out the basic type and name of every object it finds, starting with the package itself e.g. Package – MyPackage . The sample package we used last time showed nested objects as well an event handler; a OnPreExecute event tucked away on the task SQL In FEL. The output of this sample tool would look like this: PackageObjects v1.0.0.0 (1.0.0.26627) Copyright (C) 2009 Konesans Ltd Processing File - Z:\Users\Darren Green\Documents\Visual Studio 2005\Projects\SSISTestProject\EventsAndContainersWithExe cSQLForSearch.dtsx Package - EventsAndContainersWithExecSQLForSearch For Loop - FOR Counter Loop Task - SQL In Counter Loop Sequence Container - SEQ For Each Loop Wrapper For Each Loop - FEL Simple Loop Task - SQL In FEL Task - SQL On Pre Execute for FEL SQL Task Sequence Container - SEQ Top Level Sequence Container - SEQ Nested Lvl 1 Sequence Container - SEQ Nested Lvl 2 Task - SQL In Nested Lvl 2 Task - SQL In Nested Lvl 1 #1 Task - SQL In Nested Lvl 1 #2 Connection Manager – LocalHost The code is very similar to what we had previously, but there are a couple of extra bits to deal with connections and to look more closely at a task and see if it is a Data Flow task. For connections your just examine the package's Connections collection as shown in the abridged snippets below. First you can see the call to the ProcessConnections method, followed by the method itself. // Load the package file Application application = new Application(); using (Package package = application.LoadPackage(filename, null)) { // Write out the package name Console.WriteLine("Package - {0}", package.Name); ... More ... // Look and the connections ProcessConnections(package.Connections); } private static void ProcessConnections(Connections connections) { foreach (ConnectionManager connectionManager in connections) { Console.WriteLine("Connection Manager - {0}", connectionManager.Name); } } What we didn’t see in the sample output above was anything to do with the Data Flow, but rest assured the code now handles it too. The following snippet shows how each task is examined to see if it is a Data Flow task, and if so we can then loop through all of the components inside the data flow. private static void ProcessTaskHost(TaskHost taskHost) { if (taskHost == null) { return; } Console.WriteLine("Task - {0}", taskHost.Name); // Check if the task is a Data Flow task MainPipe pipeline = taskHost.InnerObject as MainPipe; if (pipeline != null) { ProcessPipeline(pipeline); } } private static void ProcessPipeline(MainPipe pipeline) { foreach (IDTSComponentMetaData90 componentMetadata in pipeline.ComponentMetaDataCollection) { Console.WriteLine("Pipeline Component - {0}", componentMetadata.Name); // If you wish to make changes to the component then you should really use the managed wrapper. // CManagedComponentWrapper wrapper = componentMetadata.Instantiate(); // wrapper.SetComponentProperty("PropertyName", "Value"); } } Hopefully you can see how we get a reference to the Data Flow task, and then use the ComponentMetaDataCollection to find out what components we have inside the pipeline. If you wanted to know more about the component you could look at the ObjectType or ComponentClassID properties. After that it gets a bit harder and you should get a reference to the wrapper object as the comment suggest and start using the properties, just like you would in the create packages samples, see our Code Development category for some for these examples. Download Sample code project PackageObjects.zip (5KB)

    Read the article

  • Lessons from a SAN Failure

    - by Bill Graziano
    At 1:10AM Sunday morning the main SAN at one of my clients suffered a “partial” failure.  Partial means that the SAN was still online and functioning but the LUNs attached to our two main SQL Servers “failed”.  Failed means that SQL Server wouldn’t start and the MDF and LDF files mostly showed a zero file size.  But they were online and responding and most other LUNs were available.  I’m not sure how SANs know to fail at 1AM on a Saturday night but they seem to.  From a personal standpoint this worked out poorly: I was out with friends and after more than a few drinks.  From a work standpoint this was about the best time to fail you could imagine.  Everything was running well before Monday morning.  But it was a long, long Sunday.  I started tipsy, got tired and ended up hung over later in the day. Note to self: Try not to go out drinking right before the SAN fails. This caught us at an interesting time.  We’re in the process of migrating to an entirely new set of servers so some things were partially moved.  This made it difficult to follow our procedures as cleanly as we’d like.  The benefit was that we had much better documentation of everything on the server.  I would encourage everyone to really think through the process of implementing your DR plan and document as much as possible.  Following a checklist is much easier than trying to remember at night under pressure in a hurry after a few drinks. I had a series of estimates on how long things would take.  They were accurate for any single server failure.  They weren’t accurate for a SAN failure that took two servers down.  This wasn’t bad but we should have communicated better. Don’t forget how many things are outside the database.  Logins, linked servers, DTS packages (yikes!), jobs, service broker, DTC (especially DTC), database triggers and any objects in the master database are all things you need backed up.  We’d done a decent job on this and didn’t find significant problems here.  That said this still took a lot of time.  There were many annoyances as a result of this.  Small settings like a login’s default database had a big impact on whether an application could run.  This is probably the single biggest area of concern when looking to recreate a server.  I’d encourage everyone to go through every single node of SSMS and look for user created objects or settings outside the database. Script out your logins with the proper SID and already encrypted passwords and keep it updated.  This makes life so much easier.  I used an approach based on KB246133 that worked well.  I’ll get my scripts posted over the next few days. The disaster can cause your DR process to fail in unexpected ways.  We have a job that scripts out all logins and role memberships and writes it to a file.  This runs on the DR server and pulls from the production server.  Upon opening the file I found that the contents were a “server not found” error.  Fortunately we had other copies and didn’t need to try and restore the master database.  This now runs on the production server and pushes the script to the DR site.  Soon we’ll get it pushed to our version control software. One of the biggest challenges is keeping your DR resources up to date.  Any server change (new linked server, new SQL Server Agent job, etc.) means that your DR plan (and scripts) is out of date.  It helps to automate the generation of these resources if possible. Take time now to test your database restore process.  We test ours quarterly.  If you have a large database I’d also encourage you to invest in a compressed backup solution.  Restoring backups was the single larger consumer of time during our recovery. And yes, there’s a database mirroring solution planned in our new architecture. I didn’t have much involvement in things outside SQL Server but this caused many, many things to change in our environment.  Many applications today aren’t just executables or web sites.  They are a combination of those plus network infrastructure, reports, network ports, IP addresses, DTS and SSIS packages, batch systems and many other things.  These all needed a little bit of attention to make sure they were functioning properly. Profiler turned out to be a handy tool.  I started a trace for failed logins and kept that running.  That let me fix a number of problems before people were able to report them.  I also ran traces to capture exceptions.  This helped identify problems with linked servers. Overall the thing that gave me the most problem was linked servers.  In order for a linked server to function properly you need to be pointed to the right server, have the proper login information, have the network routes available and have MSDTC configured properly.  We have a lot of linked servers and this created many failure points.  Some of the older linked servers used IP addresses and not DNS names.  This meant we had to go in and touch all those linked servers when the servers moved.

    Read the article

  • Juju stuck in "pending" state when using LXC

    - by Andre
    So I'm trying to get started with Juju, and tried to do this locally using LXC. I followed the instructions here: How do I configure juju for local usage? Unfortunately this doesn't seem to work for me. status shows the following: $ juju status machines: 0: agent-state: running dns-name: localhost instance-id: local instance-state: running services: mysql: charm: cs:precise/mysql-1 relations: db: - wordpress units: mysql/0: agent-state: pending machine: 0 public-address: null wordpress: charm: cs:precise/wordpress-0 exposed: true relations: db: - mysql units: wordpress/0: agent-state: pending machine: 0 open-ports: [] public-address: null 2012-05-10 14:09:38,155 INFO 'status' command finished successfully As you can see the agent-state is 'pending' and there is no public address where I'm able to access the newly created site. Am I missing something here? UPDATE: Tried destroying the environment an doing everything again (multiple times). This is the output for debug-log: ~$ juju debug-log 2012-05-11 08:50:23,790 INFO Enabling distributed debug log. 2012-05-11 08:50:23,806 INFO Tailing logs - Ctrl-C to stop. 2012-05-11 08:50:42,338 Machine:0: juju.agents.machine DEBUG: Units changed old:set([]) new:set(['mysql/0']) 2012-05-11 08:50:42,339 Machine:0: juju.agents.machine DEBUG: Starting service unit: mysql/0 ... 2012-05-11 08:50:42,459 Machine:0: unit.deploy DEBUG: Downloading charm cs:precise/mysql-1 to /home/andre/.juju/data/andre-local/charms 2012-05-11 08:50:42,620 Machine:0: unit.deploy DEBUG: Using <juju.machine.unit.UnitContainerDeployment object at 0x9c54b6c> for mysql/0 in /home/andre/.juju/data/andre-local 2012-05-11 08:50:42,648 Machine:0: unit.deploy DEBUG: Starting service unit mysql/0... 2012-05-11 08:50:42,649 Machine:0: unit.deploy DEBUG: Creating master container... 2012-05-11 08:54:33,992 Machine:0: unit.deploy DEBUG: Created master container andre-local-0-template 2012-05-11 08:54:33,993 Machine:0: unit.deploy INFO: Creating container mysql-0... 2012-05-11 08:56:18,760 Machine:0: unit.deploy INFO: Container created for mysql/0 2012-05-11 08:56:19,466 Machine:0: unit.deploy DEBUG: Charm extracted into container 2012-05-11 08:56:19,569 Machine:0: unit.deploy DEBUG: Starting container... 2012-05-11 08:56:22,707 Machine:0: unit.deploy INFO: Started container for mysql/0 2012-05-11 08:56:22,707 Machine:0: unit.deploy INFO: Started service unit mysql/0 2012-05-11 08:56:23,012 Machine:0: juju.agents.machine DEBUG: Units changed old:set(['mysql/0']) new:set(['wordpress/0', 'mysql/0']) 2012-05-11 08:56:23,039 Machine:0: juju.agents.machine DEBUG: Starting service unit: wordpress/0 ... 2012-05-11 08:56:23,154 Machine:0: unit.deploy DEBUG: Downloading charm cs:precise/wordpress-0 to /home/andre/.juju/data/andre-local/charms 2012-05-11 08:56:23,396 Machine:0: unit.deploy DEBUG: Using <juju.machine.unit.UnitContainerDeployment object at 0x9c519cc> for wordpress/0 in /home/andre/.juju/data/andre-local 2012-05-11 08:56:23,620 Machine:0: unit.deploy DEBUG: Starting service unit wordpress/0... 2012-05-11 08:56:23,621 Machine:0: unit.deploy INFO: Creating container wordpress-0... 2012-05-11 08:58:24,739 Machine:0: unit.deploy INFO: Container created for wordpress/0 2012-05-11 08:58:25,163 Machine:0: unit.deploy DEBUG: Charm extracted into container 2012-05-11 08:58:25,397 Machine:0: unit.deploy DEBUG: Starting container... 2012-05-11 08:58:27,982 Machine:0: unit.deploy INFO: Started container for wordpress/0 2012-05-11 08:58:27,983 Machine:0: unit.deploy INFO: Started service unit wordpress/0 This is the result for the status command (with verbose flag): ~$ juju -v status 2012-05-11 08:51:53,464 DEBUG Initializing juju status runtime 2012-05-11 08:51:53,625:4030(0xb7345b00):ZOO_INFO@log_env@658: Client environment:zookeeper.version=zookeeper C client 3.3.5 2012-05-11 08:51:53,625:4030(0xb7345b00):ZOO_INFO@log_env@662: Client environment:host.name=andre-ufo 2012-05-11 08:51:53,625:4030(0xb7345b00):ZOO_INFO@log_env@669: Client environment:os.name=Linux 2012-05-11 08:51:53,625:4030(0xb7345b00):ZOO_INFO@log_env@670: Client environment:os.arch=3.2.0-24-generic-pae 2012-05-11 08:51:53,625:4030(0xb7345b00):ZOO_INFO@log_env@671: Client environment:os.version=#37-Ubuntu SMP Wed Apr 25 10:47:59 UTC 2012 2012-05-11 08:51:53,626:4030(0xb7345b00):ZOO_INFO@log_env@679: Client environment:user.name=andre 2012-05-11 08:51:53,626:4030(0xb7345b00):ZOO_INFO@log_env@687: Client environment:user.home=/home/andre 2012-05-11 08:51:53,626:4030(0xb7345b00):ZOO_INFO@log_env@699: Client environment:user.dir=/home/andre 2012-05-11 08:51:53,626:4030(0xb7345b00):ZOO_INFO@zookeeper_init@727: Initiating client connection, host=192.168.122.1:41779 sessionTimeout=10000 watcher=0xb7780620 sessionId=0 sessionPasswd=<null> context=0x9242ee8 flags=0 2012-05-11 08:51:53,627:4030(0xb6b90b40):ZOO_INFO@check_events@1585: initiated connection to server [192.168.122.1:41779] 2012-05-11 08:51:53,649:4030(0xb6b90b40):ZOO_INFO@check_events@1632: session establishment complete on server [192.168.122.1:41779], sessionId=0x1373ae057d90007, negotiated timeout=10000 2012-05-11 08:51:53,651 DEBUG Environment is initialized. machines: 0: agent-state: running dns-name: localhost instance-id: local instance-state: running services: mysql: charm: cs:precise/mysql-1 relations: db: - wordpress units: mysql/0: agent-state: pending machine: 0 public-address: null wordpress: charm: cs:precise/wordpress-0 relations: db: - mysql units: wordpress/0: agent-state: pending machine: 0 public-address: null

    Read the article

  • Tuxedo 11gR1 Client Server Affinity

    - by todd.little
    One of the major new features in Oracle Tuxedo 11gR1 is the ability to define an affinity between clients and servers. In previous releases of Tuxedo, the only way to ensure that multiple requests from a client went to the same server was to establish a conversation with tpconnect() and then use tpsend() and tprecv(). Although this works it has some drawbacks. First for single-threaded servers, the server is tied up for the entire duration of the conversation and cannot service other clients, an obvious scalability issue. I believe the more significant drawback is that the application programmer has to switch from the simple request/response model provided by tpcall() to the half duplex tpsend() and tprecv() calls used with conversations. Switching between the two typically requires a fair amount of redesign and recoding. The Client Server Affinity feature in Tuxedo 11gR1 allows by way of configuration an application to define affinities that can exist between clients and servers. This is done in the *SERVICES section of the UBBCONFIG file. Using new parameters for services defined in the *SERVICES section, customers can determine when an affinity session is created or deleted, the scope of the affinity, and whether requests can be routed outside the affinity scope. The AFFINITYSCOPE parameter can be MACHINE, GROUP, or SERVER, meaning that while the affinity session is in place, all requests from the client will be routed to the same MACHINE, GROUP, or SERVER. The creation and deletion of affinity is defined by the SESSIONROLE parameter and a service can be defined as either BEGIN, END, or NONE, where BEGIN starts an affinity session, END deletes the affinity session, and NONE does not impact the affinity session. Finally customers can define how strictly they want the affinity scope adhered to using the AFFINITYSTRICT parameter. If set to MANDATORY, all requests made during an affinity session will be routed to a server in the affinity scope. Thus if the affinity scope is SERVER, all subsequent tpcall() requests will be sent to the same server the affinity scope was established with. If the server doesn't offer that service, even though other servers do offer the service, the call will fail with TPNOENT. Setting AFFINITYSTRICT to PRECEDENT tells Tuxedo to try and route the request to a server in the affinity scope, but if that's not possible, then Tuxedo can try to route the request to servers out of scope. All of this begs the question, why? Why have this feature? There many uses for this capability, but the most common is when there is state that is maintained in a server, group of servers, or in a machine and subsequent requests from a client must be routed to where that state is maintained. This might be something as simple as a database cursor maintained by a server on behalf of a client. Alternatively it might be that the server has a connection to an external system and subsequent requests need to go back to the server that has that connection. A more sophisticated case is where a group of servers maintains some sort of cache in shared memory and subsequent requests need to be routed to where the cache is maintained. Although this last case might be able to be handled by data dependent routing, using client server affinity allows the cache to be partitioned dynamically instead of statically.

    Read the article

  • Silverlight 5 &ndash; What&rsquo;s New? (Including Screenshots &amp; Code Snippets)

    - by mbcrump
    Silverlight 5 is coming next year (2011) and this blog post will tell you what you need to know before the beta ships. First, let me address people saying that it is dead after PDC 2010. I believe that it’s best to see what the market is doing, not the vendor. Below is a list of companies that are developing Silverlight 4 applications shown during the Silverlight Firestarter. Some of the companies have shipped and some haven’t. It’s just great to see the actual company names that are working on Silverlight instead of “people are developing for Silverlight”. The next thing that I wanted to point out was that HTML5, WPF and Silverlight can co-exist. In case you missed Scott Gutherie’s keynote, they actually had a slide with all three stacked together. This shows Microsoft will be heavily investing in each technology.  Even I, a Silverlight developer, am reading Pro HTML5. Microsoft said that according to the Silverlight Feature Voting site, 21k votes were entered. Microsoft has implemented about 70% of these votes in Silverlight 5. That is an amazing number, and I am crossing my fingers that Microsoft bundles Silverlight with Windows 8. Let’s get started… what’s new in Silverlight 5? I am going to show you some great application and actual code shown during the Firestarter event. Media Hardware Video Decode – Instead of using CPU to decode, we will offload it to GPU. This will allow netbooks, etc to play videos. Trickplay – Variable Speed Playback – Pitch Correction (If you speed up someone talking they won’t sound like a chipmunk). Power Management – Less battery when playing video. Screensavers will no longer kick in if watching a video. If you pause a video then screensaver will kick in. Remote Control Support – This will allow users to control playback functions like Pause, Rewind and Fastforward. IIS Media Services 4 has shipped and now supports Azure. Data Binding Layout Transitions – Just with a few lines of XAML you can create a really rich experience that is not using Storyboards or animations. RelativeSource FindAncestor – Ancestor RelativeSource bindings make it much easier for a DataTemplate to bind to a property on a container control. Custom Markup Extensions – Markup extensions allow code to be run at XAML parse time for both properties and event handlers. This is great for MVVM support. Changing Styles during Runtime By Binding in Style Setters – Changing Styles at runtime used to be a real pain in Silverlight 4, now it’s much easier. Binding in style setters allows bindings to reference other properties. XAML Debugging – Below you can see that we set a breakpoint in XAML. This shows us exactly what is going on with our binding.  WCF & RIA Services WS-Trust Support – Taken from Wikipedia: WS-Trust is a WS-* specification and OASIS standard that provides extensions to WS-Security, specifically dealing with the issuing, renewing, and validating of security tokens, as well as with ways to establish, assess the presence of, and broker trust relationships between participants in a secure message exchange. You can reduce network latency by using a background thread for networking. Supports Azure now.  Text and Printing Improved text clarity that enables better text rendering. Multi-column text flow, Character tracking and leading support, and full OpenType font support.  Includes a new Postscript Vector Printing API that provides control over what you print . Pivot functionality baked into Silverlight 5 SDK. Graphics Immediate mode graphics support that will enable you to use the GPU and 3D graphics supports. Take a look at what was shown in the demos below. 1) 3D view of the Earth – not really a real-world application though. A doctor’s portal. This demo really stood out for me as it shows what we can do with the 3D / GPU support. Out of Browser OOB applications can now create and manage childwindows as shown in the screenshot below.  Trusted OOB applications can use P/Invoke to call Win32 APIs and unmanaged libraries.  Enterprise Group Policy Support allow enterprises to lock down or up the sandbox capabilities of Silverlight 5 applications. In this demo, he tore the “notes” off of the application and it appeared in a new window. See the black arrow below. In this demo, he connected a USB Device which fired off a local Win32 application that provided the data off the USB stick to Silverlight. Another demo of a Silverlight 5 application exporting data right into Excel running inside of browser. Testing They demoed Coded UI, which is available now in the Visual Studio Feature Pack 2. This will allow you to create automated testing without writing any code manually. Performance: Microsoft has worked to improve the Silverlight startup time. Silverlight 5 provides 64-bit browser support.  Silverlight 5 also provides IE9 Hardware acceleration.   I am looking forward to Silverlight 5 and I hope you are too. Thanks for reading and I hope you visit again soon.  Subscribe to my feed CodeProject

    Read the article

  • How to install SharePoint Server 2013 Preview

    - by ybbest
    The Office 2013 and SharePoint Server 2013 Preview is announced yesterday and as a SharePoint Developer, I am really excited to learn all the new features and capabilities. Today I will show you how to install the preview. 1. Create a service account called SP2013Install and give this account Dbcreator and SecurityAdmin in SQL Server 2012 2. You need to run the following script to set the ‘maxdegree of parellism’ setting to the required value of 1 in SQL Server 2012(using sysadmin privilege) before configure the SharePoint Farm. Otherwise , you might get the error ‘This SQL Server Instance does not have the required maxdegree of parellism setting of 1’ sp_configure 'show advanced options', 1; GO RECONFIGURE WITH OVERRIDE; GO sp_configure 'max degree of parallelism', 1; GO RECONFIGURE WITH OVERRIDE; GO 3. Download the SharePoint preview from here and I am going to install it on Windows Server 2008R2 with SQL2012. 4. Click the Install software prerequisites, this works fine with the internet connection. (However, if you do not have internet connection, it is a bit tricky to install window azure AppFabric as it has to be installed using the prerequisite installer. Your computer might reboot a few times in the process.) 5.After the prerequisites are installed `completely, you can then install the Preview. Click the Install SharePoint Server and Enter the Product key you get from the Preview download page. 6. Accept the License terms and Click Next. 7. Leave the default path for the file location. 8. You can now start the installation process 9. After binary files are installed, you then can configure your farm using the farm configuration wizard. 10.Specify the Database server and the install account 11. Specify SharePoint farm passphrase. 12 Specify the port number , you should choose your own favorite port number. 13. Choose Create a New Server Farm and click next. 14. Double-check with the settings and click Next to Configure the farm install. 15. Finally, your farm is configured successfully and you now are able to go to your Central Admin site http://sp2010:6666/ 16. You should configure the services manually or automate using PowerShell (If you like to understand why,you can read the blog post here) ,however I will use the wizard to configure automatically here  as  this is a test machine. After the configuration is complete, you now be able to see your SharePoint Site. 17.To start the evaluate the Preview , you need to install Visual Studio 2012 RC , Microsoft Office Developer Tools for Visual Studio 2012,SharePoint 2013 Designer Preview , Office 2013 Preview. References: Download SharePoint2013 Server 2013 Download Microsoft Visio Professional 2013 Preview Install SharePoint 2013 Preview Hardware and software requirements for SharePoint 2013 Preview SharePoint 2013 IT Pro and Developer training materials released Plan for SharePoint 2013 Preview Microsoft Office Developer Tools for Visual Studio 2012 SharePoint 2013 Preview Office365 for the SharePoint 2013 preview SharePoint Designer 2013 Download: Microsoft Office 2013 Preview Language Pack Try Office

    Read the article

  • How to Watch NCAA March Madness Online

    - by DigitalGeekery
    You’ve filled out your brackets and now you are ready for one of America’s most popular sporting events. But what if you are you stuck at work or away from your TV?  Or your local affiliate is showing a different game? Today we show how to catch all the March Madness online. March Madness on Demand You’ll need a broadband connection, 512 MB RAM or higher, with cookies and Javascript enabled in your browser. March Madness on Demand offers two viewing options, a Standard Player and a High Quality player. The High Quality player is not, unfortunately, high definition. Standard Player Requirements Windows XP/Vista/7 or Mac OS X IE 6+ (We also successfully tested it in Firefox, Chrome, & Opera) Adobe Flash Player 9 or higher High Quality Player Requirements 2.4 GHz Pentium 4 or Intel-based Macintosh Mac OS 10.4.8+ (Intel-based) Windows: XP SP2, Vista, Server 2003, Server 2008, Windows 7 Firefox 1.5+ or IE 6/7/8 Silverlight 3 browser plug-in Watching March Madness on Demand Go to the March Madness on Demand website. (Link below) Check the “Watch in High Quality” section to see if your browser is ready and compatible for the High Quality viewer. If not, you’ll see a message indicating either your browser and system are incompatible… Or that you need to install Silverlight. To install Silverlight, click on the “Get HQ” button and follow the prompts to download and install Silverlight. To launch the player, click the large red “Launch Player” button. At the top of the screen, you’ll see the current and upcoming games. Click on “Watch Now” below to begin watching. At the bottom left, is where you click to watch with the High Quality player. If to many people are watching the High Quality player, you’ll see the following message and have to go back to the Standard Player. At the lower right are volume controls, a “Full Screen” button, and a “Share” button which allows you to share the game you are watching on various social networking sites like Facebook and Twitter. Perhaps most importantly for those who want to steal a bit of viewing time while at work is the “Boss Button” at the top right. Clicking on the “Boss Button” will open a fake Office document so it may appear at first glance like you’re actually doing legitimate work. To return to the game, click anywhere on the screen with your mouse. You’ll be able to catch every single game of the tournament from the first round all the way through the championship with March Madness on Demand. If your computer and Internet connection can handle it, you can even watch multiple games at the same time by opening March Madness on Demand in multiple browser windows. Watch March Madness online Similar Articles Productive Geek Tips Weekend Fun: Watch Television on Your PC with AnyTVWatch NFL Sunday Night Football On Your PCWatch TV On Your PC with FreeZ Online TVGeek Fun: Download Favorite NBC Programs for FreeDitch the RealPlayer Bloat with Real Alternative TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional How to Browse Privately in Firefox Kill Processes Quickly with Process Assassin Need to Come Up with a Good Name? Try Wordoid StockFox puts a Lightweight Stock Ticker in your Statusbar Explore Google Public Data Visually The Ultimate Excel Cheatsheet

    Read the article

  • Exploring packages in code

    In my previous post Searching for tasks with code you can see how to explore the control flow side of packages, drilling down through containers, task, and event handlers, but it didn’t cover the data flow. I recently saw a post on the MSDN forum asking how to edit an existing package programmatically, and the sticking point was how to find the the data flow and the components inside. This post builds on some of the previous code and shows how you can explore all objects inside a package. I took the sample Task Search application I’d written previously, and came up with a totally pointless little console application that just walks through the package and writes out the basic type and name of every object it finds, starting with the package itself e.g. Package – MyPackage . The sample package we used last time showed nested objects as well an event handler; a OnPreExecute event tucked away on the task SQL In FEL. The output of this sample tool would look like this: PackageObjects v1.0.0.0 (1.0.0.26627) Copyright (C) 2009 Konesans Ltd Processing File - Z:\Users\Darren Green\Documents\Visual Studio 2005\Projects\SSISTestProject\EventsAndContainersWithExe cSQLForSearch.dtsx Package - EventsAndContainersWithExecSQLForSearch For Loop - FOR Counter Loop Task - SQL In Counter Loop Sequence Container - SEQ For Each Loop Wrapper For Each Loop - FEL Simple Loop Task - SQL In FEL Task - SQL On Pre Execute for FEL SQL Task Sequence Container - SEQ Top Level Sequence Container - SEQ Nested Lvl 1 Sequence Container - SEQ Nested Lvl 2 Task - SQL In Nested Lvl 2 Task - SQL In Nested Lvl 1 #1 Task - SQL In Nested Lvl 1 #2 Connection Manager – LocalHost The code is very similar to what we had previously, but there are a couple of extra bits to deal with connections and to look more closely at a task and see if it is a Data Flow task. For connections your just examine the package's Connections collection as shown in the abridged snippets below. First you can see the call to the ProcessConnections method, followed by the method itself. // Load the package file Application application = new Application(); using (Package package = application.LoadPackage(filename, null)) { // Write out the package name Console.WriteLine("Package - {0}", package.Name); ... More ... // Look and the connections ProcessConnections(package.Connections); } private static void ProcessConnections(Connections connections) { foreach (ConnectionManager connectionManager in connections) { Console.WriteLine("Connection Manager - {0}", connectionManager.Name); } } What we didn’t see in the sample output above was anything to do with the Data Flow, but rest assured the code now handles it too. The following snippet shows how each task is examined to see if it is a Data Flow task, and if so we can then loop through all of the components inside the data flow. private static void ProcessTaskHost(TaskHost taskHost) { if (taskHost == null) { return; } Console.WriteLine("Task - {0}", taskHost.Name); // Check if the task is a Data Flow task MainPipe pipeline = taskHost.InnerObject as MainPipe; if (pipeline != null) { ProcessPipeline(pipeline); } } private static void ProcessPipeline(MainPipe pipeline) { foreach (IDTSComponentMetaData90 componentMetadata in pipeline.ComponentMetaDataCollection) { Console.WriteLine("Pipeline Component - {0}", componentMetadata.Name); // If you wish to make changes to the component then you should really use the managed wrapper. // CManagedComponentWrapper wrapper = componentMetadata.Instantiate(); // wrapper.SetComponentProperty("PropertyName", "Value"); } } Hopefully you can see how we get a reference to the Data Flow task, and then use the ComponentMetaDataCollection to find out what components we have inside the pipeline. If you wanted to know more about the component you could look at the ObjectType or ComponentClassID properties. After that it gets a bit harder and you should get a reference to the wrapper object as the comment suggest and start using the properties, just like you would in the create packages samples, see our Code Development category for some for these examples. Download Sample code project PackageObjects.zip (5KB)

    Read the article

  • How to create a PeopleCode Application Package/Application Class using PeopleTools Tables

    - by Andreea Vaduva
    This article describes how - in PeopleCode (Release PeopleTools 8.50) - to enable a grid without enabling each static column, using a dynamic Application Class. The goal is to disable the following grid with three columns “Effort Date”, ”Effort Amount” and “Charge Back” , when the Check Box “Finished with task” is selected , without referencing each static column; this PeopleCode could be used dynamically with any grid. If the check box “Finished with task” is cleared, the content of the grid columns is editable (and the buttons “+” and “-“ are available): So, you create an Application Package “CLASS_EXTENSIONS” that contains an Application Class “EWK_ROWSET”. This Application Class is defined with Class extends “ Rowset” and you add two news properties “Enabled” and “Visible”: After creating this Application Class, you use it in two PeopleCode Events : Rowinit and FieldChange : This code is very ‘simple’, you write only one command : ” &ERS2.Enabled = False” → and the entire grid is “Enabled”… and you can use this code with any Grid! So, the complete PeopleCode to create the Application Package is (with explanation in [….]) : ******Package CLASS_EXTENSIONS : [Name of the Package: CLASS_EXTENSIONS] --Beginning of the declaration part------------------------------------------------------------------------------ class EWK_ROWSET extends Rowset; [Definition Class EWK_ROWSET as a subclass of Class Rowset] method EWK_ROWSET(&RS As Rowset); [Constructor is the Method with the same name of the Class] property boolean Visible get set; property boolean Enabled get set; [Definition of the property “Enabled” in read/write] private [Before the word “private”, all the declarations are publics] method SetDisplay(&DisplaySW As boolean, &PropName As string, &ChildSW As boolean); instance boolean &EnSW; instance boolean &VisSW; instance Rowset &NextChildRS; instance Row &NextRow; instance Record &NextRec; instance Field &NextFld; instance integer &RowCnt, &RecCnt, &FldCnt, &ChildRSCnt; instance integer &i, &j, &k; instance CLASS_EXTENSIONS:EWK_ROWSET &ERSChild; [For recursion] Constant &VisibleProperty = "VISIBLE"; Constant &EnabledProperty = "ENABLED"; end-class; --End of the declaration part------------------------------------------------------------------------------ method EWK_ROWSET [The Constructor] /+ &RS as Rowset +/ %Super = &RS; end-method; get Enabled /+ Returns Boolean +/; Return &EnSW; end-get; set Enabled /+ &NewValue as Boolean +/; &EnSW = &NewValue; %This.InsertEnabled=&EnSW; %This.DeleteEnabled=&EnSW; %This.SetDisplay(&EnSW, &EnabledProperty, False); [This method is called when you set this property] end-set; get Visible /+ Returns Boolean +/; Return &VisSW; end-get; set Visible /+ &NewValue as Boolean +/; &VisSW = &NewValue; %This.SetDisplay(&VisSW, &VisibleProperty, False); end-set; method SetDisplay [The most important PeopleCode Method] /+ &DisplaySW as Boolean, +/ /+ &PropName as String, +/ /+ &ChildSW as Boolean +/ [Not used in our example] &RowCnt = %This.ActiveRowCount; &NextRow = %This.GetRow(1); [To know the structure of a line ] &RecCnt = &NextRow.RecordCount; For &i = 1 To &RowCnt [Loop for each Line] &NextRow = %This.GetRow(&i); For &j = 1 To &RecCnt [Loop for each Record] &NextRec = &NextRow.GetRecord(&j); &FldCnt = &NextRec.FieldCount; For &k = 1 To &FldCnt [Loop for each Field/Record] &NextFld = &NextRec.GetField(&k); Evaluate Upper(&PropName) When = &VisibleProperty &NextFld.Visible = &DisplaySW; Break; When = &EnabledProperty; &NextFld.Enabled = &DisplaySW; [Enable each Field/Record] Break; When-Other Error "Invalid display property; Must be either VISIBLE or ENABLED" End-Evaluate; End-For; End-For; If &ChildSW = True Then [If recursion] &ChildRSCnt = &NextRow.ChildCount; For &j = 1 To &ChildRSCnt [Loop for each Rowset child] &NextChildRS = &NextRow.GetRowset(&j); &ERSChild = create CLASS_EXTENSIONS:EWK_ROWSET(&NextChildRS); &ERSChild.SetDisplay(&DisplaySW, &PropName, &ChildSW); [For each Rowset child, call Method SetDisplay with the same parameters used with the Rowset parent] End-For; End-If; End-For; end-method; ******End of the Package CLASS_EXTENSIONS:[Name of the Package: CLASS_EXTENSIONS] About the Author: Pascal Thaler joined Oracle University in 2005 where he is a Senior Instructor. His area of expertise is Oracle Peoplesoft Technology and he delivers the following courses: For Developers: PeopleTools Overview, PeopleTools I &II, Batch Application Engine, Language Oriented Object PeopleCode, Administration Security For Administrators : Server Administration & Installation, Database Upgrade & Data Management Tools For Interface Users: Integration Broker (Web Service)

    Read the article

  • Oracle WebLogic Server and Oracle Database: A Robust Infrastructure for your Applications

    - by Ruma Sanyal
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 It has been said that a chain is as strong as its weakest link. Well, this is also true for your application infrastructure. Not only are the various components that constitute your infrastructure, like database and application server critical, the integration between these things [whether coming out of the box from your vendor or done in-house] is paramount. Imagine your database being down and your application server not knowing about it and as a result your application waiting indefinitely for a database response – not a great situation if high availability is critical to your application. Or one of your database nodes is very busy, but your application server doesn’t have the intelligence to decipher that – it keeps pinging the busy node when it can in fact get a response from another idle node much faster. This is what Oracle WebLogic and Database integration provides: Intelligent integration out of the box. Tight integration between Oracle WebLogic and Database makes your infrastructure robust enough that not only does each of your infrastructure component provide you with improved RASP [reliability availability, scalability, and performance] but these components work together to offer improved performance & availability, better resource sharing, inherent scalability, ease of configuration and automated management for your entire infrastructure. Oracle WebLogic Server is the only application server with this degree of integration to Oracle Database. With Oracle WebLogic Server 11g, we introduced Active GridLink for Real Application Clusters (RAC). In conjunction with Oracle Database, this powerful software technology simplifies management, increases availability, and ensures fast connection failover with runtime connection, load balancing and affinity capabilities. With the release of Oracle Database 12c this summer, even tighter integration between Oracle WebLogic Server 12c (12.1.2) and Oracle Database 12c has been achieved and this further optimizes the integration for a global cloud environment. Read about these capabilities in detail in the Oracle WebLogic-Database Integration Whitepaper. Get in depth ‘how-to’ details from this YouTube video on the topic from our resident expert, Monica Roccelli. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

    Read the article

  • Process Centric Banking: Loan Origination Solution

    - by Manish Palaparthy
    There is an old proverb that goes, "The difference between theory and practice is greater in practice than in theory". So, we keep doing numerous "Proof of Concepts" with our own products on various business cases to analyze them deeply, understand and explain to our customers. We then present our learnings as they happened. The awareness of each PoC should help readers increase the trustworthiness of the results coming out of these PoCs. I present one such PoC where we invested a lot of time&effort.  Process Centric Banking : Loan Origination Solution Loan Origination is a process by which a borrower applies for a new loan and the lender processes that application. Loan origination includes the series of steps taken by the bank from the point the customer shows interest in a loan product all the way to disbursal of funds. The Loan Origination process is relevant for many kind of lenders in Financial services: Banks, Credit Unions, NBFCs(Non Banking Financial Companies) and so on. For simplicity sake, I will use "Bank" as the lending institution in the rest of my article.  Loan Origination is one of the core processes for Banks as it is the process by which the it creates assets against which the Institution earns most of its profits from. A well tuned loan origination process can affect the Bank in many positive ways. Banks have always shown great interest in automating the loan origination process for the above reason. However, due the constant changes in customer environment, market dynamics, prevailing economic conditions, cost pressures & regulatory environment they run into lot of challenges. Let me categorize some of these challenges for you Customer Environment Multiple Channels: Customer can use any of the available channels (Internet Banking, Email, Fax, Branch, Phone Banking, ATM, Broker, Mobile, Snail Mail) to perform all or some of the activities related to her Visibility into the origination process: Expect immediate update on the status of loan processing & alert messages Reduced Turn Around Time: Expect loans to be processed with least turn around time Reduced loan processing fees: Partly due to market dynamics the customer expects the loan processing fee to be negligible Market Dynamics Competitive environment:  The competition keeps creating many variants of loan products to attract customers, the bank needs to create similar product variants with better offers to attract customers or keep existing ones Ability to migrate loans from one vendor to another: It has become really easy for retail customers to move from one bank to the other given the low fee of loan processing and highly attractive offers. How does the bank protect it's customer base while actively engaging with potential customers banking with competitor banks Flexibility to react to market developments: Market development greatly influence loan processing, underwriting, asset valuation, risk mitigation rules. Can the bank modify rules and policies, the idea is not just to react to market developments but to pro-actively manage new developments Economic conditions Constant change in various rates and their implications on the rates and rules applied when on-boarding a loan: How quickly can the bank apply changes to rates offered to customers when the central bank changes various rates Requirements of Audit by the central banker: Tough economic conditions have demanded much more stringent audit rules and tests. The banks needs to produce ready reports(historic & operational) for audit compliance Risk Mitigation: While risk mitigation has always been a key concern for the bank, this is the area where the bank's underwriters & risk analysts spend the maximum time when processing a loan application. In order to reduce TAT the bank cannot compromise on its risk mitigation strategies Cost pressures Reduce Cost of processing per application: To deliver a reduced loan processing fee to the customer, the bank needs to keep its cost per processing loan application low. Meet customer TAT expectations while reducing the queues and the systems being used to process the loan application: The loan application could potentially be spending a lot of time waiting in the queue for further processing. Different volumes & patterns of applications demand different queuing algorithms. The bank needs to have real-time visibility into these queues and have the flexibility to change queuing algorithms at runtime  Increase the use of electronic communication and reduce the branch channel usage: Lesser automation leads not only leads to Increased turn around time, it also impacts more costs to reach out to customers The objective of our PoC was to implement a Loan Origination Solution whose ownership lies with the bank and effectively meet the challenges listed above. We built a simple story board for the solution We then went about implementing our storyboard using Oracle BPM Suite, Webcenter Content : Imaging. The web UI has been built on ADF technolgies, while the integration with core-services has been implemented using the underlying SOA infrastructure. The BPM process model is quite exhaustive can meet all the challenges listed above to reasonable degree. A bank intending to implement an end-to-end Loan Origination Solution has multiple options at it's disposal. It can Develop a customer Loan Origination Application from scratch: Gives maximum opportunity to build what you want but inflexible to upgrade and maintain. Higher TCO in long term Buy a Packaged application & customize it: Customizing a generic loan application can be tedious and prove as difficult as above. Build it using many disparate & un-integrated tools: Initially seems easier than developing from scratch. But, without integrated tool sets this is not a viable approach either or A solution based on a Framework: Independent Services and Business Process Modeling provide decoupled architecture that is flexible. We built this framework end-to-end with processes the core process of loan origination & several sub-processes such as Analyse and define customer needs, customer credit verification, identity check processes, legal review process, New customer registration & risk assessment.

    Read the article

  • Ajax Autocomplete Extender

    - by Jason Ulloa
    El objetivo de este post es preparar un ejemplo sobre un tema que es planteado muy frecuentemente en los Foros de MSDN, como realizar un Autocomplete contra una base de datos. Qué requerimos? Antes de poder realizar un Autocomplete debemos tener en cuenta los elementos principales que requerimos para poder hacerlo funcionar, descritos de la siguiente manera: 1. Textbox: Nuestro grandioso amigo Textbox, que será donde el usuario ingresará los datos a buscar. 2. Un Webservice: que contendrá el método que se conectara a la base de datos y devolverá una lista con la información encontrada. 3. Ajax Autocomplete Extender: este es por decirlo así, el elemento más importante. Nos servirá como medio de enlace entre el webservice que expone el método y el textbox recuperando y mostrando los datos en forma de lista desplegable. La implementación Si bien parecierá complicado, crear un autocomplete extender es bastante sencillo. Empezaremos creando un nuevo sitio asp.net, en este sitio agregaremos un textbox y dos controles muy importantes de Ajax el ToolkitScriptManager para controlar el rende rizado de los script de ajax y el AutocompleteExtender que, como mencione anteriormente, será el medio de enlace. Antes de mostrar como quedará el código de lo anterior, explicaré algunas propiedades del AutocompleteExtender para que se entienda de mejor manera: 1. El ServicePath: contiene la ruta relativa al webservice que utilizaremos. 2. MinimumPrefixLength: se refiere al número de caracteres que deben ser digitados antes de iniciar la búsqueda. 3. ServiceMethod: el nombre del metodo de nuestro webservice que se encargará de devolver los datos. 4. EnableCaching: para mantener en cache los datos consultados, obteniendo mayor velocidad. 5. TargetControlID: una de las propiedades más importantes, acá se coloca el nombre del textbox al cual se unirá el Autocomplete 6. CompletionInterval: tiempo que debe transcurrir antes de iniciar con el trabajo de los datos. Una vez, explicadas las propiedades básicas, veamos como queda implementada la primer parte de nuestro autocomplete: <form id="form1" runat="server"> <div> <asp:ToolkitScriptManager ID="manager" runat="server" /> <asp:TextBox ID="TextBox1" runat="server"></asp:TextBox> <asp:AutoCompleteExtender ID="AutoCompleteExtender1" runat="server" ServicePath="WebService.asmx" MinimumPrefixLength="1" ServiceMethod="PersonasInfo " EnableCaching="true" TargetControlID="TextBox1" UseContextKey="True" CompletionSetCount="10" CompletionInterval="0"> </asp:AutoCompleteExtender> </div> </form>   Ahora que nuestro código html está completo, es hora de trabajar directamente con nuestro webservice, este deberá contener un método que devuelva una lista o arreglo de datos, los cuales por supuesto, serán traídos desde la base de datos. Antes de implementar este método, debemos asegurarnos de que nuestra clase del webservice tiene habilitados los espacios para ser utilizada [System.Web.Script.Services.ScriptService()] [WebService(Namespace = "http://tempuri.org/")] [WebServiceBinding(ConformsTo = WsiProfiles.BasicProfile1_1)] public class WebService : System.Web.Services.WebService {}   Ahora si, nuestro metodo principal [WebMethod()] [System.Web.Script.Services.ScriptMethod()] public string[] PersonasInfo(string prefixText, int count) { string connstring = ConfigurationManager.ConnectionStrings["LocalSqlServer"].ConnectionString;   using (SqlConnection conn = new SqlConnection(connstring)) { SqlCommand comando = new SqlCommand("select nombre from personas where nombre LIKE '%' + @param + '%' ", conn); comando.Parameters.AddWithValue("@param", prefixText); SqlDataReader dr = default(SqlDataReader); comando.Connection.Open(); dr = comando.ExecuteReader(); List<string> items = new List<string>();   while (dr.Read()) { items.Add(dr["nombre"].ToString()); } comando.Connection.Close(); return items.ToArray(); } }   Del método anterior no explicaré en profundidad, pues es bastante sencillo. Una consulta a la base de datos utilizando un datareader y devolviendo los datos en una lista como arreglo. Lo más importante serían las 2 primeras líneas [WebMethod()] y el [ScriptMethod()] las cuales habilitan nuestro método para poder ser accedido y utilizado. Por último, el código de ejemplo en C# (VB Autcomplete):

    Read the article

  • Remote Desktop (Vino-Server) connects but display doesn't work?

    - by kmassada
    Ubuntu comes default with vino-server, I can remote into my machine, and connect to it, however, the display inside my remote client, is a mirror of my own desktop. I tried using one monitor, thinking that's what is the issue but still won't work. (vino-server:3608): EggSMClient-CRITICAL **: egg_sm_client_set_mode: assertion `global_client == NULL || global_client_mode == EGG_SM_CLIENT_MODE_DISABLED' failed 25/07/2012 12:23:58 PM Autoprobing TCP port in (all) network interface 25/07/2012 12:23:58 PM Listening IPv6://[::]:5900 25/07/2012 12:23:58 PM Listening IPv4://0.0.0.0:5900 25/07/2012 12:23:58 PM Autoprobing selected port 5900 25/07/2012 12:23:58 PM Advertising security type: 'TLS' (18) 25/07/2012 12:23:58 PM Re-binding socket to listen for VNC connections on TCP port 5900 in (all) interface 25/07/2012 12:23:58 PM Listening IPv6://[::]:5900 25/07/2012 12:23:58 PM Listening IPv4://0.0.0.0:5900 25/07/2012 12:23:58 PM Clearing securityTypes 25/07/2012 12:23:58 PM Advertising security type: 'TLS' (18) 25/07/2012 12:23:58 PM Clearing securityTypes 25/07/2012 12:23:58 PM Advertising security type: 'TLS' (18) 25/07/2012 12:23:58 PM Advertising authentication type: 'No Authentication' (1) 25/07/2012 12:23:58 PM Re-binding socket to listen for VNC connections on TCP port 5900 in (all) interface 25/07/2012 12:23:58 PM Listening IPv6://[::]:5900 25/07/2012 12:23:58 PM Listening IPv4://0.0.0.0:5900 25/07/2012 12:23:58 PM Clearing securityTypes 25/07/2012 12:23:58 PM Clearing authTypes 25/07/2012 12:23:58 PM Advertising security type: 'TLS' (18) 25/07/2012 12:23:58 PM Advertising authentication type: 'VNC Authentication' (2) 25/07/2012 12:23:58 PM Clearing securityTypes 25/07/2012 12:23:58 PM Clearing authTypes 25/07/2012 12:23:58 PM Advertising security type: 'TLS' (18) 25/07/2012 12:23:58 PM Advertising authentication type: 'VNC Authentication' (2) 25/07/2012 12:23:58 PM Advertising security type: 'VNC Authentication' (2) (vino-server:3608): LIBDBUSMENU-GLIB-WARNING **: Trying to remove a child that doesn't believe we're it's parent. (vino-server:3608): LIBDBUSMENU-GLIB-WARNING **: Trying to remove a child that doesn't believe we're it's parent. 25/07/2012 12:24:16 PM [IPv4] Got connection from client static-XXXX.bltmmd.fios.verizon.net 25/07/2012 12:24:16 PM other clients: 25/07/2012 12:24:29 PM Client Protocol Version 3.7 25/07/2012 12:24:29 PM Advertising security type 18 25/07/2012 12:24:29 PM Advertising security type 2 25/07/2012 12:24:30 PM Client returned security type 18 25/07/2012 12:24:30 PM Advertising authentication type 2 25/07/2012 12:24:30 PM Client returned authentication type 2 25/07/2012 12:24:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -258 25/07/2012 12:24:37 PM Enabling NewFBSize protocol extension for client static-XXXX.bltmmd.fios.verizon.net 25/07/2012 12:24:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type 1464686185 25/07/2012 12:24:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -259 25/07/2012 12:24:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -257 (vino-server:3608): LIBDBUSMENU-GLIB-WARNING **: Trying to remove a child that doesn't believe we're it's parent. 25/07/2012 12:24:55 PM Client static-XXXX.bltmmd.fios.verizon.net gone 25/07/2012 12:24:55 PM Statistics: 25/07/2012 12:24:55 PM key events received 0, pointer events 80 25/07/2012 12:24:55 PM framebuffer updates 43, rectangles 152, bytes 292401 25/07/2012 12:24:55 PM tight rectangles 152, bytes 292401 25/07/2012 12:24:55 PM raw bytes equivalent 11621332, compression ratio 39.744502 25/07/2012 12:25:21 PM [IPv4] Got connection from client static-XXXX.bltmmd.fios.verizon.net 25/07/2012 12:25:21 PM other clients: 25/07/2012 12:25:28 PM Client Protocol Version 3.7 25/07/2012 12:25:28 PM Advertising security type 18 25/07/2012 12:25:28 PM Advertising security type 2 25/07/2012 12:25:28 PM Client returned security type 18 25/07/2012 12:25:29 PM Advertising authentication type 2 25/07/2012 12:25:29 PM Client returned authentication type 2 25/07/2012 12:25:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -258 25/07/2012 12:25:37 PM Enabling NewFBSize protocol extension for client static-XXXX.bltmmd.fios.verizon.net 25/07/2012 12:25:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type 1464686185 25/07/2012 12:25:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -259 25/07/2012 12:25:37 PM rfbProcessClientNormalMessage: ignoring unknown encoding type -257 (vino-server:3608): LIBDBUSMENU-GLIB-WARNING **: Trying to remove a child that doesn't believe we're it's parent. 25/07/2012 12:25:47 PM Client static-XXXX.bltmmd.fios.verizon.net gone 25/07/2012 12:25:47 PM Statistics: 25/07/2012 12:25:47 PM key events received 0, pointer events 7283 25/07/2012 12:25:47 PM framebuffer updates 27, rectangles 82, bytes 113354 25/07/2012 12:25:47 PM tight rectangles 82, bytes 113354 25/07/2012 12:25:47 PM raw bytes equivalent 5831432, compression ratio 51.444431 couple of things I notice, the following error occurs over and over again. the menu error seems to be caused by ubuntu, similar problems occur http://trac.wxwidgets.org/ticket/14292, (vino-server:3608): LIBDBUSMENU-GLIB-WARNING **: Trying to remove a child that doesn't believe we're it's parent. the second one also seem to be a display related issue, can't seem to figure out a solution. I really rather try to fix this issue than have to use the other vnc clients most suggest. (vino-server:3608): EggSMClient-CRITICAL **: egg_sm_client_set_mode: assertion `global_client == NULL || global_client_mode == EGG_SM_CLIENT_MODE_DISABLED' failed

    Read the article

  • Application Module Extension in Oracle Application R12

    - by Manoj Madhusoodanan
    In this blog I will describe how to Extend Application Module.I will explain this based on my previous blog PL/SQL based EO.  I want to extend FndUserAM to add a procedure to raise a custom business event when the FND_USER has created successfully. Here I am using a custom business event "xxcust.oracle.apps.demo_event". Please find the code used in Business Event. TablePackage Following steps needs to perform. 1) Download all files pertaining to "Entity Object Based on PL/SQL" to JDEV_USER_HOME/myprojects and JDEV_USER_HOME/myclasses.If you want to see the content of source java file decompile it and save it in JDEV_USER_HOME/myprojects. 2) Create XXFndUserAM as follows. 3) Add following method to XXFndUserAMImpl.    import oracle.apps.fnd.framework.OAException;   import oracle.apps.fnd.framework.server.OADBTransactionImpl;   import oracle.apps.fnd.wf.bes.BusinessEvent;   import oracle.apps.fnd.wf.bes.BusinessEventException;    import java.sql.Connection;     public void raiseEvent(String userName) {        String eventName = "xxcust.oracle.apps.demo_event";        String eventKey = userName;        Connection conn = ((OADBTransactionImpl)getOADBTransaction()).getJdbcConnection();         BusinessEvent event = null;         try{             event = new BusinessEvent(eventName, eventKey);             /* Setting Parameters */             event.setStringProperty("USER_NAME",userName);             event.setStringProperty("STATUS","User has created sucessfully");             event.raise(conn);             }             catch (BusinessEventException e) {                 throw new OAException("Exception occured when invoking web service - "+e.getMessage());             }             getOADBTransaction().commit();    } 4) Create a controller which extends from xxcust.oracle.apps.fnd.user.webui.CreateFndUserCO.Call raiseEvent method from new controller. 5) Create substitution for FndUserAM. 6) Migrate following files to $JAVA_TOP. xxcustom.oracle.apps.fnd.user.server.FndUserAMImpl.javaxxcustom.oracle.apps.fnd.user.server.XXFndUserAM.xmlxxcustom.oracle.apps.fnd.user.webui.XXCreateFndUserCO.java 8) Migrate the substitution. 9) Restart the server. 10) Personalize the page /xxcust/oracle/apps/fnd/user/webuiCreateFndUserPG and set the new controller. 11) Verify the substitution has properly applied by clicking About the Page. 12) Access the page and create a user. You can the the result of the Business Event.

    Read the article

  • saving and retrieving a text file in java?

    - by user3319432
    import java.sql. ; import java.awt.; import javax.swing.; import java.awt.event.; public class saving extends JFrame implements ActionListener{ JTextField edpno=new JTextField(10); JLabel l0= new JLabel ("EDP Number: "); JComboBox fname = new JComboBox(); JLabel l1= new JLabel("First Name: "); JTextField lname= new JTextField(20); JLabel l2= new JLabel("Last Name: "); // JTextField contno= new JTextField(20); // JLabel l3= new JLabel("Contact Number: "); JComboBox contno = new JComboBox(); JLabel l3 = new JLabel ("Contact Number: "); JButton bOK = new JButton("Save"); JButton bRetrieve = new JButton("Retrieve"); private ImageIcon icon; JPanel C=new JPanel(){ protected void paintComponent(Graphics g){ g.drawImage(icon.getImage(),0,0,null); super.paintComponent(g); } }; public Search Record (){ icon=new ImageIcon("images/canres.png"); C.setOpaque(false); C.setLayout(new GridLayout(5,2,4,4)); setTitle("Search Record"); C.add (l0); C.add (edpno); edpno.addActionListener(this); C.add (l1); C.add (fname); fname.setForeground(Color.BLUE); fname.setFont(new Font(" ", Font.BOLD,15)); C.add (l2); C.add (lname); C.add (l3); C.add (contno); contno.setForeground(Color.BLUE); contno.setFont(new Font(" ", Font.BOLD,15)); C.add(bOK); bOK.addActionListener(this); C.add (bRetrieve); bRetrieve.addActionListener(this); bOK.setBackground(Color.white); bRetrieve.setBackground(Color.white); } public void saverecord(){ try{ //Connect to the Database Class.forName("sun.jdbc.odbc.JdbcOdbcDriver"); String path ="jdbc:odbc:;DRIVER=Microsoft Access Driver (*.mdb);DBQ=Database/roomassign.mdb"; String DBPassword =""; String DBUserName =""; Connection con = DriverManager.getConnection(path,"",""); Statement s = con.createStatement(); s.executeQuery("select firstname, Lastname, contact number from name WHERE edpno ='"+edpno.getText()+"'"); ResultSet rs = s.getResultSet(); ResultSetMetaData md = rs.getMetaData(); while(rs.next()) { fname.setSelectedItem(rs.getString(1)); lname.setText(rs.getString(2)); contno.setSelectedItem(rs.getString(3)); // crs.setSelectedItem(rs.getString(4)); } s.close(); con.close(); } catch(Exception Q) { JOptionPane.showMessageDialog(this,Q); } } public void SaveRecord(){ try{ Class.forName("sun.jdbc.odbc.JdbcOdbcDriver"); String path = "jdbc:odbc:;DRIVER=Microsoft Access Driver (*.mdb);DBQ=Database/roomassign.mdb"; String DBPassword =""; String DBUsername =""; Connection con = DriverManager.getConnection(path,"",""); Statement s = con.createStatement(); String sql = "UPDATE rooms SET Firstname='"+fname.getSelectedItem()+"',Lastname='"+lname.getText()+"',Contactnumber='"+contno.getSelectedItem()+"' WHERE '"+edpno.getText()+"'=edpno"; s.executeUpdate(sql); JOptionPane.showMessageDialog(this,"New room Record has been successfully saved"); dispose(); s.close(); con.close(); } catch(Exception Mismatch){ JOptionPane.showMessageDialog(this,Mismatch); } } public void actionPerformed (ActionEvent ako){ if (ako.getSource() == bRetrieve){ dispose(); } else if (ako.getSource() == bOK){ SaveRecord(); } } public static void main (String [] awtsave){ new Search(); } }

    Read the article

  • Session Sharing with another User on *NIX and Windows

    - by Giri Mandalika
    Oracle Solaris Since Solaris is not widely known for its graphical interface, let's just focus on sharing a terminal session in read-only mode with another user on the same system. Here is an example. eg., % finger Login Name TTY Idle When Where root Super-User pts/1 Sat 16:57 dhcp-amer-vpn-rmdc-a sunperf ??? pts/2 4 Sat 16:41 pitcher.sfbay.sun.com In this example, two users root and sunperf are connected to the same system from two different terminals pts/1 and pts/2 respectively. If the root user wants to show something to sunperf user -- what s/he is doing in her/his terminal, for example, it can be accomplished with the following command. script -a /dev/null | tee -a <target_terminal eg., # script -a /dev/null | tee -a /dev/pts/2 Script started, file is /dev/null # # uptime 5:04pm up 1 day(s), 2:56, 2 users, load average: 0.81, 0.81, 0.81 # # isainfo -v 64-bit sparcv9 applications crc32c cbcond pause mont mpmul sha512 sha256 sha1 md5 camellia kasumi des aes ima hpc vis3 fmaf asi_blk_init vis2 vis popc 32-bit sparc applications crc32c cbcond pause mont mpmul sha512 sha256 sha1 md5 camellia kasumi des aes ima hpc vis3 fmaf asi_blk_init vis2 vis popc v8plus div32 mul32 # # exit Script done, file is /dev/null After the script .. | tee .. command, sunperf user should be able to see the root user's stdin and stdout contents in her/his own terminal until the script session exits in root user's terminal. Since this kind of sharing is based on capturing and redirecting the contents to the target terminal, the users on the receiving end won't be able to see whatever is being edited on initiators' terminal [using editors such as vi]. Also it is not possible to share the session with any connected user on the system unless the initiator has the necessary permissions and privileges. The script utility records everything printed in a terminal session, while the tee utility replicates the contents of the screen capture on to the standard output of the target terimal. The tee utility does not buffer the output - so, the screen capture from the initiators' terminal appears almost right away in the target terminal. Though I never tested, this technique may work on all *NIX and Linux flavors with little or no changes. Also there might be other ways to accomplish this. [Thanks to Sujeet for sharing this tip] Microsoft Windows Most of the Windows users may rely on VNC services to share a desktop session. Another way to share the desktop session is to use the Remote Desktop Connection (RDC) client. Here are the steps. Connect to the target Windows system using Remote Desktop Connection client Launch Windows Task Manager Navigate to the "Users" tab Find the user session that you want to connect to and have full control over as the other user who is currently holding that session Select the user name in Windows Task Manager, right click and choose the option "Remote Control" A window pops up on the other user's session with the message "<USER is requesting to control your session remotely. Do you accept the request?" Once the other user says "Yes", you will be granted access to that session. Since then both users should be able to see the same screen and even control the session from their respective workstations.

    Read the article

  • A Knights Tale

    - by Phil Factor
    There are so many lessons to be learned from the story of Knight Capital losing nearly half a billion dollars as a result of a deployment gone wrong. The Knight Capital Group (KCG N) was an American global financial services firm engaging in market making, electronic execution, and institutional sales and trading. According to the recent order (File No.3.15570) against Knight Capital by U.S. Securities and Exchange Commission?, Knight had, for many years used some software which broke up incoming “parent” orders into smaller “child” orders that were then transmitted to various exchanges or trading venues for execution. A tracking ‘cumulative quantity’ function counted the number of ‘child’ orders and stopped the process once the total of child orders matched the ‘parent’ and so the parent order had been completed. Back in the mists of time, some code had been added to it  which was excuted if a particular flag was set. It was called ‘power peg’ and seems to have had a similar design and purpose, but, one guesses, would have shared the same tracking function. This code had been abandoned in 2003, but never deleted. In 2005, The tracking function was moved to an earlier point in the main process. It would seem from the account that, from that point, had that flag ever been set, the old ‘Power Peg’ would have been executed like Godzilla bursting from the ice, making child orders without limit without any tracking function. It wasn’t, presumably because the software that set the flag was removed. In 2012, nearly a decade after ‘Power Peg’ was abandoned, Knight prepared a new module to their software to cope with the imminent Retail Liquidity Program (RLP) for the New York Stock Exchange. By this time, the flag had remained unused and someone made the fateful decision to reuse it, and replace the old ‘power peg’ code with this new RLP code. Had the two actions been done together in a single automated deployment, and the new deployment tested, all would have been well. It wasn’t. To quote… “Beginning on July 27, 2012, Knight deployed the new RLP code in SMARS in stages by placing it on a limited number of servers in SMARS on successive days. During the deployment of the new code, however, one of Knight’s technicians did not copy the new code to one of the eight SMARS computer servers. Knight did not have a second technician review this deployment and no one at Knight realized that the Power Peg code had not been removed from the eighth server, nor the new RLP code added. Knight had no written procedures that required such a review.” (para 15) “On August 1, Knight received orders from broker-dealers whose customers were eligible to participate in the RLP. The seven servers that received the new code processed these orders correctly. However, orders sent with the repurposed flag to the eighth server triggered the defective Power Peg code still present on that server. As a result, this server began sending child orders to certain trading centers for execution. Because the cumulative quantity function had been moved, this server continuously sent child orders, in rapid sequence, for each incoming parent order without regard to the number of share executions Knight had already received from trading centers. Although one part of Knight’s order handling system recognized that the parent orders had been filled, this information was not communicated to SMARS.” (para 16) SMARS routed millions of orders into the market over a 45-minute period, and obtained over 4 million executions in 154 stocks for more than 397 million shares. By the time that Knight stopped sending the orders, Knight had assumed a net long position in 80 stocks of approximately $3.5 billion and a net short position in 74 stocks of approximately $3.15 billion. Knight’s shares dropped more than 20% after traders saw extreme volume spikes in a number of stocks, including preferred shares of Wells Fargo (JWF) and semiconductor company Spansion (CODE). Both stocks, which see roughly 100,000 trade per day, had changed hands more than 4 million times by late morning. Ultimately, Knight lost over $460 million from this wild 45 minutes of trading. Obviously, I’m interested in all this because, at one time, I used to write trading systems for the City of London. Obviously, the US SEC is in a far better position than any of us to work out the failings of Knight’s IT department, and the report makes for painful reading. I can’t help observing, though, that even with the breathtaking mistakes all along the way, that a robust automated deployment process that was ‘all-or-nothing’, and tested from soup to nuts would have prevented the disaster. The report reads like a Greek Tragedy. All the way along one wants to shout ‘No! not that way!’ and ‘Aargh! Don’t do it!’. As the tragedy unfolds, the audience weeps for the players, trapped by a cruel fate. All application development and deployment requires defense in depth. All IT goes wrong occasionally, but if there is a culture of defensive programming throughout, the consequences are usually containable. For financial systems, these defenses are required by statute, and ignored only by the foolish. Knight’s mistakes weren’t made by just one hapless sysadmin, but were progressive errors by an  IT culture spanning at least ten years.  One can spell these out, but I think they’re obvious. One can only hope that the industry studies what happened in detail, learns from the mistakes, and draws the right conclusions.

    Read the article

  • Setup and configure a MVC4 project for Cloud Service(web role) and SQL Azure

    - by MagnusKarlsson
    I aim at keeping this blog post updated and add related posts to it. Since there are a lot of these out there I link to others that has done kind of the same before me, kind of a blog-DRY pattern that I'm aiming for. I also keep all mistakes and misconceptions for others to see. As an example; if I hit a stacktrace I will google it if I don't directly figure out the reason for it. I will then probably take the most plausible result and try it out. If it fails because I misinterpreted the error I will not delete it from the log but keep it for future reference and for others to see. That way people that finds this blog can see multiple solutions for indexed stacktraces and I can better remember how to do stuff. To avoid my errors I recommend you to read through it all before going from start to finish.The steps:Setup project in VS2012. (msdn blog)Setup Azure Services (half of mpspartners.com blog)Setup connections strings and configuration files (msdn blog + notes)Export certificates.Create Azure package from vs2012 and deploy to staging (same steps as for production).Connections string error Set up the visual studio project:http://blogs.msdn.com/b/avkashchauhan/archive/2011/11/08/developing-asp-net-mvc4-based-windows-azure-web-role.aspx Then login in to Azure to setup the services:Stop following this guide at the "publish website" part since we'll be uploading a package.http://www.mpspartners.com/2012/09/ConfiguringandDeployinganMVC4applicationasaCloudServicewithAzureSQLandStorage/ When set up (connection strings for debug and release and all), follow this guide to set up the configuration files:http://msdn.microsoft.com/en-us/library/windowsazure/hh369931.aspxTrying to package our application at this step will generate the following warning:3>MvcWebRole1(0,0): warning WAT170: The configuration setting 'Microsoft.WindowsAzure.Plugins.Diagnostics.ConnectionString' is set up to use the local storage emulator for role 'MvcWebRole1' in configuration file 'ServiceConfiguration.Cloud.cscfg'. To access Windows Azure storage services, you must provide a valid Windows Azure storage connection string. Right click the web role under roles in solution manager and choose properties. Choose "Service configuration: Cloud". At "specify storage account credentials" we will copy/paste our account name and key from the Azure management platform.3.1 4. Right click Remote desktop Configuration and select certificate and export to file. We need to allow it in Portal manager.4.15 Now right click the cloud project and select package.5.1 Showing dialogue box. 5.2 Package success Now copy the path to the packaged file and go to management portal again. Click your web role and choose staging (or production). Upload. 5.3Tick the box about the single instance if that's what you want or you don't know what it means. Otherwise the following will happen (see image 4.6)5.4 Dialogue box When you have clicked the symbol for accept- button you will see the following screen with some green indicators down at the right corner. Click them if you want to see status.5.5 Information screen.5.6 "Failed to deploy application. The upload application has at least one role with only one instance. We recommend that you deploy at least two instances per role to ensure high availability in case one of the instances becomes unavailable. "To fix, go to step 5.4If you forgot to (or just didn't know you were supposed to) export your certificates. The following error will occur. Side note, the following thread suggests. To prevent: "Enable Remote Desktop for all roles" when right-clicking BIAB and choosing "Package". But in my case it was the not so present certificates. I fund the solution here.http://social.msdn.microsoft.com/Forums/en-US/dotnetstocktradersampleapplication/thread/0e94c2b5-463f-4209-86b9-fc257e0678cd5.75.8 Success! 5.9 Nice URL n' all. (More on that at another blog post).6. If you try to login and getWhen this error occurs many web sites suggest this is because you need:http://nuget.org/packages/Microsoft.AspNet.Providers.LocalDBOr : http://nuget.org/packages/Microsoft.AspNet.ProvidersBut it can also be that you don't have the correct setup for converting connectionstrings between your web.config to your debug.web.config(or release.web.config, whichever your using).Run as suggested in the "ordinary project in your solution. Go to the management portal and click update.

    Read the article

  • Starting over and new to Ubuntu

    - by 2funnyyone
    We have been having repeated problems with our interent service and using windows xp & sp3 (users and premissions) I see no need for them. I started with computers long before windows. Every since sp 3 come out in 2009 I have had nothing but problems. I have lost so many computers to virius and trojans, we just stack them up. We are with Qwest/ Century link which is using advertising servers which I think is causing the problem. All the computers are networked together which is not how I set them up. I beleive Century link is networking them through assignment of a domain for our home. This causes all the computers to crash twice. This is getting expensive. We tried buying new harddrives but reinfect with hours of connecting to internet. I also beleive the modem, router and all computers are infected. I put combofix on this one and that is the only reason we are still online with this laptop. I am afraid to install new equipment because my partner and I are on SSDI and this cost a lot. I go to school at UOP and had to run off a flash and reboot this laptop to recovery every other day or so, this pass month. New plan is: We are getting ready to install new equipment but afraid to reinfect again. Need help to install new equipment. The plan is to use current internet services from Qwest/ now Century Link. The list of New equipment in order: Century link wireless modem is ZyXEL PK5000Z with 4 direct connect Ethernet ports Next Dell Optiplex 210L ( used auction purchase ) 2 gb ram 80 g hard drive Ubuntu 11.10 operating system Next Wireless D-Link router WBR-1310 with 4 direct connect Ethernet ports OK-------- Purchased Dell OEM disk for Repair or Reinstalling Windows XP Professional Operating system (2 roommates as well) All infected computers are Dell desktops or laptops with XP Pro Also purchasing Ubuntu 12.04 for 3 computers. We like the way it runs but still learning it. Questions 1] How do we fdisk the infected computers without infecting new system. We have Dos disks, but none have floppy dish drive. We do have a new floppy disk drive and usb adapter we purchased from Amazon. 2] We are thinking Avast internet security because of the boot scan. We want all software loaded before reconnecting. We can manually load our internet provider information. We purchased StopZilla $100 for 5 computers, but not sure that is what we need. But need how to setup ports security and services we will need. Really lost at this part. So we are safe when we go back on the internet. 3] Want to connect reloaded fdisk systems to router as public connection and no sharing. Do not want to network all computers. 4] Want parental/ ownership control from Ubuntu system for internet connection (Children and friends). Do we restrict at the modem and/ or router? Any help would be a blessing. I do not want to go alone on this anymore.

    Read the article

  • What's wrong with my wireless?

    - by dazzle
    I am having issues with my wireless connection. My connection is constantly disconnecting, then attempting to reconnect, reconnecting momentarily, then disconnecting etc. on times scales that range from seconds to minutes. In the meantime, needless to say I'm having significant packet loss. I'm running Ubuntu 14.04 64bit, updated and upgraded to today. Here is my card and driver: delta@sager:~$ lspci -vq | grep -i wireless -B 1 -A 5 04:00.0 Network controller: Intel Corporation Wireless 7260 (rev 73) Subsystem: Intel Corporation Dual Band Wireless-AC 7260 Flags: bus master, fast devsel, latency 0, IRQ 47 Memory at f7d00000 (64-bit, non-prefetchable) [size=8K] Capabilities: Kernel driver in use: iwlwifi Here is my kernel: delta@sager:~$ uname -r 3.13.0-34-generic None of the other machines on my home network are having these issues. Windows Vista is networking without issue for goodness sake ;-) Here is a small clipping from the output of dmesg. As you can see, I am getting a cfg80211 message of some sort over and over again (FYI, I've replaced my MAC address with a series of dashes, so anytime there is a ---------------, that was where the MAC address was: [ 1881.739161] wlan1: authenticate with --------------- [ 1881.741561] wlan1: send auth to --------------- (try 1/3) [ 1881.743440] wlan1: authenticated [ 1881.746027] wlan1: associate with --------------- (try 1/3) [ 1881.749244] wlan1: RX AssocResp from --------------- (capab=0x411 status=0 aid=4) [ 1881.754727] wlan1: associated [ 1881.754827] cfg80211: Calling CRDA for country: US [ 1881.761552] cfg80211: Regulatory domain changed to country: US [ 1881.761559] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 1881.761564] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2700 mBm) [ 1881.761568] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 1700 mBm) [ 1881.761571] cfg80211: (5250000 KHz - 5330000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1881.761574] cfg80211: (5490000 KHz - 5600000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1881.761577] cfg80211: (5650000 KHz - 5710000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1881.761580] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 3000 mBm) [ 1881.761584] cfg80211: (57240000 KHz - 63720000 KHz @ 2160000 KHz), (N/A, 4000 mBm) [ 1882.391038] cfg80211: Calling CRDA to update world regulatory domain [ 1882.396254] cfg80211: World regulatory domain updated: [ 1882.396260] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 1882.396265] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1882.396268] cfg80211: (2457000 KHz - 2482000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1882.396271] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 1882.396274] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1882.396277] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1886.148252] wlan1: authenticate with --------------- [ 1886.150005] wlan1: send auth to --------------- (try 1/3) [ 1886.151807] wlan1: authenticated [ 1886.154847] wlan1: associate with --------------- (try 1/3) [ 1886.158147] wlan1: RX AssocResp from --------------- (capab=0x411 status=0 aid=4) [ 1886.163464] wlan1: associated [ 1886.163520] wlan1: Limiting TX power to 30 (30 - 0) dBm as advertised by --------------- [ 1886.163588] cfg80211: Calling CRDA for country: US [ 1886.170500] cfg80211: Regulatory domain changed to country: US [ 1886.170508] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 1886.170513] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2700 mBm) [ 1886.170517] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 1700 mBm) [ 1886.170520] cfg80211: (5250000 KHz - 5330000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1886.170523] cfg80211: (5490000 KHz - 5600000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1886.170526] cfg80211: (5650000 KHz - 5710000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1886.170529] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 3000 mBm) [ 1886.170533] cfg80211: (57240000 KHz - 63720000 KHz @ 2160000 KHz), (N/A, 4000 mBm) [ 1887.200197] cfg80211: Calling CRDA to update world regulatory domain [ 1887.203655] cfg80211: World regulatory domain updated: [ 1887.203659] cfg80211: (start_freq - end_freq @ bandwidth), (max_antenna_gain, max_eirp) [ 1887.203662] cfg80211: (2402000 KHz - 2472000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1887.203664] cfg80211: (2457000 KHz - 2482000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1887.203666] cfg80211: (2474000 KHz - 2494000 KHz @ 20000 KHz), (300 mBi, 2000 mBm) [ 1887.203668] cfg80211: (5170000 KHz - 5250000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) [ 1887.203670] cfg80211: (5735000 KHz - 5835000 KHz @ 40000 KHz), (300 mBi, 2000 mBm) I've poked around on AskUbuntu, and have not found any adequate solutions; have also found similar threads that were left unanswered. Any advice/experience/threads I might be able to pull on would be greatly appreciated. In your opinion, is this a kernel issue, hardware issue, etc.? Thanks in advance. EDIT: chili, here's the output of iwconfig: delta@sager:~$ iwconfig wlan1 IEEE 802.11abg ESSID:"LANbeforetime" Mode:Managed Frequency:2.412 GHz Access Point: ----------- Bit Rate=48 Mb/s Tx-Power=16 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off Link Quality=44/70 Signal level=-66 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:80 Missed beacon:0 eth0 no wireless extensions. lo no wireless extensions.

    Read the article

  • My shiny new gadget

    - by TechTwaddle
    About 3 months ago when I had tweeted (or twit?) that the HD7 could be my next phone I wasn’t a 100 percent sure, and when the HTC Mozart came out it was switch at first sight. I wanted to buy the Mozart mainly for three reasons; its unibody construction, smaller screen and the SLCD display. But now, holding a HD7 in my hand, I reminisce and think about how fate had its own plan. Too dramatic for a piece of gadget? Well, sort of, but seriously, this has been most exciting. So in short, I bought myself a HTC HD7 and am really loving it so far. Here are some pics (taken from my HD2 which now lies in a corner, crying),     Most of my day was spent setting up the device. Email accounts, Facebook, Marketplace etc. Since marketplace isn’t officially launched in India yet, my primary live id did not work. Whenever I tried launching marketplace it would say ‘marketplace is not currently supported in your country’. Searching the forums I found an easy work around. Just create a dummy live id with the country set to UK or US and log in to the device using this id. I was worried if the contacts and feeds from my primary live account would not be updated but that was not a problem. Adding another live account into the device does import your contacts, calendar and feeds from it. And that’s it, marketplace now works perfectly. I installed a few trial and free applications; haven’t checked if I can purchase apps though, will check that later and update this post. There is one issue I am still facing with the device, I can’t access the internet over GPRS. Windows Phone 7 only gives you the option to add an ‘APN’ and nothing else. Checking the connection settings on my HD2, I found out that there is also a proxy server I need to add to access GPRS, but so far I haven’t found a way to do that on WP7. Ideally HTC should have taken care of this, detect the operator and apply that operators settings on the device, but looks like that’s not happening. I also tried the ‘Connection Settings’ application that HTC bundled with the device, but it did nothing magical. If you’re reading this and know how to fix this problem please leave a comment. The next thing I did is install apps, a lot of apps. Read Engadget’s guide to essential apps for WP7. The apps and games I installed so far include Beezz (twitter app with push notifications), twitter (the official twitter app), Facebook, Youtube, NFS Undercover, Rocket Riot, Krashlander, Unite and the list goes on. All the apps run super smooth. The display looks fine indoors but I know it’s going to suck in bright sunlight. Anyhow, I am really impressed with what I’ve seen so far. I leave you with a few more photos. Have a great year ahead. Ciao!

    Read the article

  • ODEE Green Field (Windows) Part 3 - SOA Suite

    - by AndyL-Oracle
     So you're still here, are you? I'm sure you're probably overjoyed at the prospect of continuing with our green field installation of ODEE. In my previous post, I covered the installation of WebLogic - you probably noticed, like I did, that it's a pretty quick install. I'm pretty certain this had everything to do with how quickly the next post made it to the internet! So let's dig in. Make sure you've followed the steps from the initial post to obtain the necessary software and prerequisites! Unpack the RCU (Repository Creation Utility). This ZIP file contains a directory (rcuHome) that should be extracted into your ORACLE_HOME. Run the RCU – execute rcuHome/bin/rcu.bat. Click Next. Select Create and click Next. Enter the database connection details and click Next – any failure to connection will show in the Messages box. Click Ok Expand and select the SOA Infrastructure item. This will automatically select additional required components. You can change the prefix used, but DEV is recommended. If you are creating a sandbox that includes additional components like WebCenter Content and UMS, you may select those schemas as well but they are not required for a basic ODEE installation. Click Next. Click OK. Specify the password for the schema(s). Then click Next. Click Next. Click OK. Click OK. Click Create. Click Close. Unpack the SOA Suite installation files into a single directory e.g. SOA. Run the installer – navigate and execute SOA/Disk1/setup.exe. If you receive a JDK error, switch to a command line to start the installer. To start the installer via command line, do Start?Run?cmd and cd into the SOA\Disk1 directory. Run setup.exe –jreLoc < pathtoJRE >. Ensure you do not use a path with spaces – use the ~1 notation as necessary (your directory must not exceed 8 characters so “Program Files” becomes “Progra~1” and “Program Files (x86)” becomes “Progra~2” in this notation). Click Next. Select Skip and click Next. Resolve any issues shown and click Next. Verify your oracle home locations. Defaults are recommended. Click Next. Select your application server. If you’ve already installed WebLogic, this should be automatically selected for you. Click Next. Click Install. Allow the installation to progress… Click Next. Click Finish. You can save the installation details if you want. That should keep you satisfied for the moment. Get ready, because the next posts are going to be meaty! 

    Read the article

  • Observing flow control idle time in TCP

    - by user12820842
    Previously I described how to observe congestion control strategies during transmission, and here I talked about TCP's sliding window approach for handling flow control on the receive side. A neat trick would now be to put the pieces together and ask the following question - how often is TCP transmission blocked by congestion control (send-side flow control) versus a zero-sized send window (which is the receiver saying it cannot process any more data)? So in effect we are asking whether the size of the receive window of the peer or the congestion control strategy may be sub-optimal. The result of such a problem would be that we have TCP data that we could be transmitting but we are not, potentially effecting throughput. So flow control is in effect: when the congestion window is less than or equal to the amount of bytes outstanding on the connection. We can derive this from args[3]-tcps_snxt - args[3]-tcps_suna, i.e. the difference between the next sequence number to send and the lowest unacknowledged sequence number; and when the window in the TCP segment received is advertised as 0 We time from these events until we send new data (i.e. args[4]-tcp_seq = snxt value when window closes. Here's the script: #!/usr/sbin/dtrace -s #pragma D option quiet tcp:::send / (args[3]-tcps_snxt - args[3]-tcps_suna) = args[3]-tcps_cwnd / { cwndclosed[args[1]-cs_cid] = timestamp; cwndsnxt[args[1]-cs_cid] = args[3]-tcps_snxt; @numclosed["cwnd", args[2]-ip_daddr, args[4]-tcp_dport] = count(); } tcp:::send / cwndclosed[args[1]-cs_cid] && args[4]-tcp_seq = cwndsnxt[args[1]-cs_cid] / { @meantimeclosed["cwnd", args[2]-ip_daddr, args[4]-tcp_dport] = avg(timestamp - cwndclosed[args[1]-cs_cid]); @stddevtimeclosed["cwnd", args[2]-ip_daddr, args[4]-tcp_dport] = stddev(timestamp - cwndclosed[args[1]-cs_cid]); @numclosed["cwnd", args[2]-ip_daddr, args[4]-tcp_dport] = count(); cwndclosed[args[1]-cs_cid] = 0; cwndsnxt[args[1]-cs_cid] = 0; } tcp:::receive / args[4]-tcp_window == 0 && (args[4]-tcp_flags & (TH_SYN|TH_RST|TH_FIN)) == 0 / { swndclosed[args[1]-cs_cid] = timestamp; swndsnxt[args[1]-cs_cid] = args[3]-tcps_snxt; @numclosed["swnd", args[2]-ip_saddr, args[4]-tcp_dport] = count(); } tcp:::send / swndclosed[args[1]-cs_cid] && args[4]-tcp_seq = swndsnxt[args[1]-cs_cid] / { @meantimeclosed["swnd", args[2]-ip_daddr, args[4]-tcp_sport] = avg(timestamp - swndclosed[args[1]-cs_cid]); @stddevtimeclosed["swnd", args[2]-ip_daddr, args[4]-tcp_sport] = stddev(timestamp - swndclosed[args[1]-cs_cid]); swndclosed[args[1]-cs_cid] = 0; swndsnxt[args[1]-cs_cid] = 0; } END { printf("%-6s %-20s %-8s %-25s %-8s %-8s\n", "Window", "Remote host", "Port", "TCP Avg WndClosed(ns)", "StdDev", "Num"); printa("%-6s %-20s %-8d %@-25d %@-8d %@-8d\n", @meantimeclosed, @stddevtimeclosed, @numclosed); } So this script will show us whether the peer's receive window size is preventing flow ("swnd" events) or whether congestion control is limiting flow ("cwnd" events). As an example I traced on a server with a large file transfer in progress via a webserver and with an active ssh connection running "find / -depth -print". Here is the output: ^C Window Remote host Port TCP Avg WndClosed(ns) StdDev Num cwnd 10.175.96.92 80 86064329 77311705 125 cwnd 10.175.96.92 22 122068522 151039669 81 So we see in this case, the congestion window closes 125 times for port 80 connections and 81 times for ssh. The average time the window is closed is 0.086sec for port 80 and 0.12sec for port 22. So if you wish to change congestion control algorithm in Oracle Solaris 11, a useful step may be to see if congestion really is an issue on your network. Scripts like the one posted above can help assess this, but it's worth reiterating that if congestion control is occuring, that's not necessarily a problem that needs fixing. Recall that congestion control is about controlling flow to prevent large-scale drops, so looking at congestion events in isolation doesn't tell us the whole story. For example, are we seeing more congestion events with one control algorithm, but more drops/retransmission with another? As always, it's best to start with measures of throughput and latency before arriving at a specific hypothesis such as "my congestion control algorithm is sub-optimal".

    Read the article

  • Microsoft Sql Server 2008 R2 System Databases

    For a majority of software developers little time is spent understanding the inner workings of the database management systems (DBMS) they use to store data for their applications.  I personally place myself in this grouping. In my case, I have used various versions of Microsoft’s SQL Server (2000, 2005, and 2008 R2) and just recently learned how valuable they really are when I was preparing to deliver a lecture on "SQL Server 2008 R2, System Databases". Microsoft Sql Server 2008 R2 System DatabasesSo what are system databases in MS SQL Server, and why should I know them? Microsoft uses system databases to support the SQL Server DBMS, much like a developer uses config files or database tables to support an application. These system databases individually provide specific functionality that allows MS SQL Server to function. Name Database File Log File Master master.mdf mastlog.ldf Resource mssqlsystemresource.mdf mssqlsystemresource.ldf Model model.mdf modellog.ldf MSDB msdbdata.mdf msdblog.ldf Distribution distmdl.mdf distmdl.ldf TempDB tempdb.mdf templog.ldf Master DatabaseIf you have used MS SQL Server then you should recognize the Master database especially if you used the SQL Server Management Studio (SSMS) to connect to a user created database. MS SQL Server requires the Master database in order for DBMS to start due to the information that it stores. Examples of data stored in the Master database User Logins Linked Servers Configuration information Information on User Databases Resource DatabaseHonestly, until recently I never knew this database even existed until I started to research SQL Server system databases. The reason for this is due largely to the fact that the resource database is hidden to users. In fact, the database files are stored within the Binn folder instead of the standard MS SQL Server database folder path. This database contains all system objects that can be accessed by all other databases.  In short, this database contains all system views and store procedures that appear in all other user databases regarding system information. One of the many benefits to storing system views and store procedures in a single hidden database is the fact it improves upgrading a SQL Server database; not to mention that maintenance is decreased since only one code base has to be mainlined for all of the system views and procedures. Model DatabaseThe Model database as the name implies is the model for all new databases created by users. This allows for predefining default database objects for all new databases within a MS SQL Server instance. For example, if every database created by a user needs to have an “Audit” table when it is  created then defining the “Audit” table in the model will guarantees that the table will be located in every new database create after the model is altered. MSDB DatabaseThe MSDBdatabase is used by SQL Server Agent, SQL Server Database Mail, SQL Server Service Broker, along with SQL Server. The SQL Server Agent uses this database to store job configurations and SQL job schedules along with SQL Alerts, and Operators. In addition, this database also stores all SQL job parameters along with each job’s execution history.  Finally, this database is also used to store database backup and maintenance plans as well as details pertaining to SQL Log shipping if it is being used. Distribution DatabaseThe Distribution database is only used during replication and stores meta data and history information pertaining to the act of replication data. Furthermore, when transactional replication is used this database also stores information regarding each transaction. It is important to note that replication is not turned on by default in MS SQL Server and that the distribution database is hidden from SSMS. Tempdb DatabaseThe Tempdb as the name implies is used to store temporary data and data objects. Examples of this include temp tables and temp store procedures. It is important to note that when using this database all data and data objects are cleared from this database when SQL Server restarts. This database is also used by SQL Server when it is performing some internal operations. Typically, SQL Server uses this database for the purpose of large sort and index operations. Finally, this database is used to store row versions if row versioning or snapsot isolation transactions are being used by SQL Server. Additionally, I would love to hear from others about their experiences using system databases, tables, and objects in a real world environments.

    Read the article

  • BizTalk 2009 - The Community ODBC Adapter: Schema Generation

    - by Stuart Brierley
    Having previously detailed the installation of the Community ODBC Adapter for BizTalk 2009, the next thing I will be looking at is the generation of schemas using this ODBC adapter. Within your BizTalk 2009 project, right click the project and select Add Generated Items.  In the resultant window choose Add Adapter Metadata and click Add to open the Add Adapter Wizard. Check that the BizTalk Server and Database names are correct, select the ODBC adapter and click next. You must now set the connection string. To start with choose set, then new DSN (data source name). You now need to define the Data Source you will be connecting to.  On the User DSN tab select Add add then driver you want to use. In this case I am going to use the MySQL ODBC Driver.  A User DSN will only be visible on the current machine with you as a user. * Although I initially set up a User DSN and this was fine for creating schemas with, I later realised that you actually need a system DSN as the BizTalk host service needs this to be able connect to the database on a receive or send port. You will then be asked to Set up the MySQL ODBC Data Source.  In my case this is a local database making use of named pipes, so I had to make sure that I ticked the "Force use of named pipes" check box and removed the "# The Pipe the MySQL Server will use socket=mysql" line from the mysql.ini; with this is place the connection would fail as there is no apparent way to specify the pipe name in the ODBC driver configuration. This will then update the User DSN tab with the new Data Source.  Make sure that you select it and press OK. Select it again in the Choose Data Source window and press OK.  On the ODBC transport window select next. You will now be presented with the Schema Information window, where you must supply the namespace, type and root element names for your schema. Next choose the type of statement that you will be using to create your schema - in this case I am using a stored procedure. *I later discovered that this option is fine for MySQL stored procedures without input parameters, but failed for MySQL stored procedures with input parameters.  (I will be posting on the way to handle input parameters soon) Next you will need to specify the name of the stored procedure.  In this case I have a simple stored procedure to return all the data held by my TestTable in MySQL. Select * from TestTable; The table itself has three columns: Name, Sex and Married. Selecting finish should now hopefully create your schemas based on the input and output from your stored procedure. In my case I have:   An empty schema for the request; after all I have no parameters for the stored procedure.  A response schema comprised of a Table Record with Name, Sex and Married children. Next I will be looking at the use of the ODBC adpater with: Receive ports Send ports

    Read the article

< Previous Page | 304 305 306 307 308 309 310 311 312 313 314 315  | Next Page >