Search Results

Search found 8410 results on 337 pages for 'hardware reserved'.

Page 316/337 | < Previous Page | 312 313 314 315 316 317 318 319 320 321 322 323  | Next Page >

  • Dangers of Running Computers w/o Air Conditioning

    - by Daniel Bingham
    I recently moved in to an apartment with out air conditioning. This is fine most of the time as I am in upstate New York. It only ever gets above the high 70s during the hottest of the summer months. And when it does, I'm stubborn enough that I'll just deal with wearing minimal clothing around the house. However, I'm worried about my computers. I'm a software developer and gamer, so many of my machines are very high powered. And at least one of them is a server that must be left on 24/7 (not just a game server - also serves multiple websites). I've never before had to worry about the heat too much, as I always lived in buildings with central air. The in building temperature rarely got much above 70 F. All of the machines I built had good enough air cooling that I never saw a problem. Now the temperature in building is pushing 100F and I'm worried that the machines will not be able to keep themselves cool enough by simply blowing already hot air over themselves. The hottest of them I've turned off. However, the server I cannot. It's an old Dell (not custom build) that runs on a Pentium 4 (2.2GHz). It only has a single hard drive, integrated video. And it'd not running any processor intensive servers. Just basic LAMP. It used to run a MUD server, but that's off for now. So it should be idling most of the time. I haven't been able to find any sort of built in temperature sensors in the hardware... at least not any that the programs I've found in the Debian repository can read. And it's an inherited machine to which I do not have the full specs, so I don't know the tolerances anyway. How worried should I be about it melting down on me? How worried should I be about the hard drive melting or becoming corrupted? To generalize the question for other people, what are the safe temperature tolerances for most machines. How widely does it vary, and how does one go about determining when their machine is running too hot and needs to be shut down?

    Read the article

  • How to get wireless working (properly) with Sitecom Wireless USB micro adapter 300N on Windows 7?

    - by Timo
    The question says it all, but more detail follows ;) I've got a new computer that runs Windows 7 64-bits (Home Edition) and I'd like to connect it to my wireless home network (Sitecom wireless gigabit router 300N wl-352 v1 002) with a Sitecom wireless USB micro adaptapter 300 wl-352 V2 001. After installing the router (i.e. connected to the modem and power) and ensuring that wireless is indeed enabled, I've installed the driver of the USB adapter on the new computer described above. After the installation (drivers and utility on CD) completes successfull I rebooted my computer and inserted the USB adapter. After discovering the right network and connecting to it using the network key, a connection is succesfully made. (Using the Sitecom 300N USB Wireless LAN utility). In the LAN utility I can see that the signal strength is approximately 50% and connection quality is approximately 80%. Judging from these numbers I assumed that all was fine and started to use the connection (reading news on nu.nl, a dutch news site), but noticed that the connection was lost several times in a very short time span, but each time the connections was resumed, resulting in the 50/80 percent numbers described above. However, the website was not loaded completely and often a timeout would be reported. When inspecting the drivers through Device Management (Windows' Apparaatbeheer in dutch) there were no errors/warnings; everything seemed to be in order. In an attempt to solve this, I downloaded the latest drivers for the USB adapter, but the problems remained. Finally I tried to connect the computer with a Siemens Gigaset USB Adapter 108. This process was a troublesome since I had to download a driver (from the site above) and tell Windows (7) to use the Windows Vista driver when installing the new hardware, since there is (was) no Windows 7 driver available. This resulted in a usable connection, although not very stable when reconfiguring the router. Which took the form of selecting a different wireless channel on the router, even using the Sitecom utility mentioned above to check if there were other networks communicating on that channel (and thus picking a channel that was not used by other networks). Again no result when changing back to the Sitecom USB adapter. Note that this means (I think) that I could use the internet connection with the Siemens adapter, meaning the problem was not in the router. So: How to get wireless working (properly) with Sitecom Wireless USB micro adapter 300N on Windows 7? PS Sorry, but should be able to post one link, while I had links in place for the USB adapter, router and the siemens adapter in place as well, but I'm not (yet) allowed to post these... (The site says I can post one link, but only when no links are present will it allow me to post the question...)

    Read the article

  • Laptop turning off when fan is spinning hard

    - by Ieyasu Sawada
    My laptop seems to have reach its lifespan. Its an Acer laptop so I guess that's normal. But I'd like to hear your opinions about this. My laptop is only 2 years old. I haven't heard the fan spinning like crazy not until these past 5 months. What I did: Hoping that its just the applications that I have installed that's consume the life of my laptop from the background. I used PC Decrapifier to uninstall some of the things that I don't need. Reformatted my computer but only the primary partition since my files are on the second partition. Bought a cooling pad. None of these works. I noticed the fan spins so hard when: I have a lot of browser tabs open. Full screen mode a flash video that I'm viewing online. Using VLC to watch encoded videos. There's this thing called minicoder http://sourceforge.net/projects/minicoder/ to reduce the size of videos without affecting much of the quality. I'm suspecting that it needs additional software(to make life easier for the hardware) even though the video is working fine in VLC. VLC consumes about 300,000K and above(as seen from task manager) while watching videos (.mkv). The problem: Laptop suddenly turns off when the fan spins like crazy for about 20 minutes. I'm always checking to see if its already too hot(using my fingers to feel the side of the laptop) but its not so I continued watching and then poof! computer turns off. Laptop won't turn on immediately when I turn it on after it turning off by itself. The light for the power goes on but its turns off immediately. I have to wait for about 10-20 seconds before it boots up without problems. So how do I go about this? Is this just normal for Acer laptops after about 2 years of heavy usage (8-12 hours a day)? My usage is heavy but I normally only have a text-editor(sublime) and browser open(chrome). Here's what I got from HW monitor:

    Read the article

  • What other tool is using my hotkey?

    - by Sammy
    I use Greenshot for screenshots, and it's been nagging about some other software tool using the same hotkey. I started receiving this warning message about two days ago. It shows up each time I reboot and log on to Windows. The hotkey(s) "Ctrl + Shift + PrintScreen" could not be registered. This problem is probably caused by another tool claiming usage of the same hotkey(s)! You could either change your hotkey settings or deactivate/change the software making use of the hotkey(s). What's this all about? The only software I recently installed is CPU-Z Core Temp Speed Fan HD Tune Epson Print CD NetStress What I would like to know is how to find out what other tool is causing this conflict? Do I really have to uninstall each program, one by one, until there is no conflict anymore? I see no option for customizing any hotkeys in CPU-Z, and according to docs there are only a few keyboard shortcuts. These are F5 through F9, but they are no hotkeys. There is nothing in Core Temp, and from what I can see... nothing in Speed Fan. Is any of these programs known to use Ctrl + Shift + PrintScreen hotkey for screenshots? I am actually suspecting the Dropbox client. I think I saw a warning recently coming from Dropbox program, something to do with hotkeys or keyboard shortcuts. I see that it has an option for sharing screenshots under Preferences menu, but I see no option for hotkeys. Core Temp actually also has an option for taking screenshots (F9) but it's just that - a keyboard shortcut, not a hotkey. And again, there's no option actually for changing this setting in Options/Settings menu. How do you resolve this type of conflicts? Are there any general methods you can use to pinpoint the second conflicting software? Like... is there some Windows registry key that holds the hotkeys? Or is it just down to mere luck and trial and error? Addendum I forgot to mention, when I do use the Ctrl + Shift + PrintScreen hotkey, what happens is that the Greenshot context menu shows up, asking me where I want to save the screenshot. So it appears to be working. But I am still getting the darn warning every time I reboot and log on to Windows?! I actually tried changing the key bindings in Greenshot preferences, but after a reboot it seems to have returned back to the settings I had previously. Update I can't see any hotkey conflicts in the Widnows Hotkey Explorer. The aforementioned hotkey is reserved by Greenshot, and I don't see any other program using the same hotkey binding. But when I went into Greenshot preferences, this is what I discovered. As you can see it's the Greenshot itself that uses the same hotkey twice! I guess that's why no other program was listed above as using this hotkey. But how can Greenshot be so stupid to use the same hotkey more than once? I didn't do this! It's not my fault... I'm not that stupid. This is what it's set to right now: Capture full screen: Ctrl + Skift + Prntscrn Capture window: Alt + Prntscrn Capture region: Ctrl + Prntscrn Capture last region: Skift + Prntscrn Capture Internet Explorer: Ctrl + Skift + Prntscrn And this is my preferred setting: Capture full screen: Prntscrn Capture window: Alt + Prntscrn Capture region: Ctrl + Prntscrn Capture last region: Capture Internet Explorer: I don't use any hotkey for "last region" and IE. But when I set this to my liking, as listed here, Greenshot gives me the same warning message, even as I tab through the hotkey entry fields. Sometimes it even gives me the warning when I just click Cancel button. This is really crazy! On the side note... You might have noticed that I have "update check" set to 0 (zero). This is because, in my experience, Greenshot changes all or only some of my preferences back to default settings whenever it automatically updates to a new version. So I opted to stay off updates to get rid of the problem. It has done so for the past three updates or so. I hoped to receive a new update that would fix the issue, but I think it still reverts back to default settings after each update to a new version, including setting default hotkeys. Update 2 I'll give you just one example of how Greenshot behaves. This is the dialog I have in front of me right now. As you can see, I have removed the last two hotkeys and changed the first one to my own liking. While I was clicking in the fields and removing the two hotkeys I was getting the warning message. So let's say I click in the "capture last region" field. Then I get this: Note that none of the entries include "Ctrl + Shift + PrintScreen" that it's warning about. Now I will change all the hotkeys so I get something like this: So now I'm using QWERTY letters for binding, like Ctrl+Alt+Q, Ctrl+Alt+W and so on. As far as I know no Windows program is using these. While I was clicking through the different fields it was giving me the warning. Now when I try to click OK to save the changes, it once again gives me a warning about "ctrl + shift + printscreen". Update 3 After setting the above key bindings (QWERTY) and saving changes, and then rebooting, the conflict seems to have been resolved. I was then able to set following key bindings. Capture full screen: Prntscrn Capture window: Alt + Prntscrn Capture region: Ctrl + Prntscrn I was not prompted with the warning message this time. Perhaps changing key binding required a system reboot? Sounds far fetched but that appears to be the case. I'm still not sure what caused this conflict, but I know for sure that it started after installing aforementioned programs. It might just have to do with Greenshot itself, and not some other program. Like I said, I know from experience that Greenshot likes to mess with users' settings after each update. I wouldn't be surprised if it was actually silently updated, even though I have specified not to check for updates, then it changed the key bindings back to defaults and caused a conflict with the hotkeys that were registered with the operating system previously. I rarely reboot the system, so that could have added to the conflict. Next time if I see this I will run Hotkey Explorer immediately and see if there is another program causing the conflict.

    Read the article

  • Pxe net install Centos with Static IP

    - by Stu2000
    I seem to be unable to perform a kickstart installation of centos5.8 with a netinstall. It correctly gets into the text installer, but keeps sending out a request for the dhcp server and failing. I have tried to manually set the IP everywhere. Here is my pxelinux.cfg file DEFAULT menu PROMPT 0 MENU TITLE Ubuntu MAAS TIMEOUT 200 TOTALTIMEOUT 6000 ONTIMEOUT local LABEL centos5.8-net kernel /images/centos5.8-net/vmlinuz MENU LABEL centos5.8-net append initrd=/images/centos5.8-net/initrd.img ip=192.168.1.163 netmask=255.255.255.0 hostname=client101 gateway=192.168.1.1 ksdevice=eth0 dns=8.8.8.8 ks=http://192.168.1.125/cblr/svc/op/ks/profile/centos5.8-net MENU end and here is my kickstart file: # Kickstart file for a very basic Centos 5.8 system # Assigns the server ip: 192.211.48.163 # DNS 8.8.8.8, 8.8.4.4 # London TZ install url --url http://mirror.centos.org/centos-5/5.8/os/i386 lang en_US.UTF-8 keyboard us network --device=eth0 --bootproto=static --ip=192.168.1.163 --netmask=255.255.255.0 --gateway=192.168.1.1 --nameserver=8.8.8.8,8.8.4.4 --hostname=client1-server --onboot=on rootpw --iscrypted $1$Snrd2bB6$CuD/07AX2r/lHgVTPZyAz/ firewall --enabled --port=22:tcp authconfig --enableshadow --enablemd5 selinux --enforcing timezone --utc Europe/London bootloader --location=mbr --driveorder=xvda --append="console=xvc0" # The following is the partition information you requested # Note that any partitions you deleted are not expressed # here so unless you clear all partitions first, this is # not guaranteed to work part /boot --fstype ext3 --size=100 --ondisk=xvda part pv.2 --size=0 --grow --ondisk=xvda volgroup VolGroup00 --pesize=32768 pv.2 logvol swap --fstype swap --name=LogVol01 --vgname=VolGroup00 --size=528 --grow --maxsize=1056 logvol / --fstype ext3 --name=LogVol00 --vgname=VolGroup00 --size=1024 --grow %packages @base @core @dialup @editors @text-internet keyutils iscsi-initiator-utils trousers bridge-utils fipscheck device-mapper-multipath sgpio emacs Here is my dhcp file: ddns-update-style interim; allow booting; allow bootp; ignore client-updates; set vendorclass = option vendor-class-identifier; subnet 192.168.1.0 netmask 255.255.255.0 { host tower { hardware ethernet 50:E5:49:18:D5:C6; fixed-address 192.168.1.163; option routers 192.168.1.1; option domain-name-servers 8.8.8.8,8.8.4.4; option subnet-mask 255.255.255.0; filename "/pxelinux.0"; default-lease-time 21600; max-lease-time 43200; next-server 192.168.1.125; } } Is it impossible to prevent it asking for a dynamic ip before trying to install from the net? Perhaps there is an error in of my files? My dhcp server is set to ignore client-updates, and is set to only works with one mac address whilst testing.

    Read the article

  • Server 2008/Windows 7/Samba Unspecified error 80004005

    - by ancillary
    I have a Samba share on a LAN with 2008 PDC/DNS. Smb authenticates with AD and I have several Win7 Machines that can connect fine. I recently added a couple of new computers to the LAN which were imaged the same way (same software, etc.; different hardware so different drivers) as the other machines and they have the same policies set. I can not get the new machines to connect to the samba share no matter what. I am always met with either Unspecified Error 0x80004005 or Network Path not found. I've turned off the firewall; set LANMAN auth to respond to NTLM only/send LM & NTLM responses/use NTLM session security if negotiated in Local Sec Policy SEcurity Options; tried both ip and hostname to connect. SMB log shows that authentication succeeds; but then connection is immediately killed by the client. tcpdump shows nothing remarkable except that when trying to connect from the client via hostname there is an unknown packet type error: ack 201 win 255 NBT Session Packet: Unknown packet type 0xABData: (41 bytes) Here's a couple of lines from that error: 11:18:37.964991 IP 001-client.domain.local.49372 > smb.domain.local.netbios-ssn: P 1670:2146(476) ack 201 win 255 NBT Session Packet: Unknown packet type 0xABData: (41 bytes) [000] AA 46 96 FA D5 99 33 75 0C C4 20 CE 26 42 F3 61 \252F\226\372\325\2313u \014\304 \316&B\363a [010] F0 8C FB 65 18 17 40 A5 DB 42 BB 94 37 53 92 EC \360\214\373e\030\027@\245 \333B\273\2247S\222\354 [020] 55 98 7F C4 AE 3D 6B 10 C4 U\230\177\304\256=k\020 \304 11:18:37.964998 IP smb.domain.local.netbios-ssn > 001-client.domain.local.49372: . ack 2146 win 100 Here's smb.conf just in case (though don't see how if other machines are working fine): [global] workgroup = MYDOMAIN realm = MYDOMAIN.LOCAL server string = domain|smb share interfaces = eth1 security = ADS password server = 192.168.1.3 log level = 2 log file = /var/log/samba/%m.log smb ports = 139 strict locking = no load printers = No local master = No domain master = No wins server = 192.168.1.3 wins support = Yes idmap uid = 500-10000000 idmap gid = 500-10000000 winbind separator = + winbind enum users = Yes winbind enum groups = Yes winbind use default domain = Yes [samba-share1] comment = SMB Share path = /home/share/smb/ valid users = @"MYDOMAIN+Domain Users" admin users = @"MYDOMAIN+Domain Admins" guest ok = no read only = No create mask = 0765 force directory mode = 0777 Any ideas what else I could try or look for? Or what might be the problem? Thanks.

    Read the article

  • How to resolve `bootpd` crashing constantly on Mac OS X 10.6.4 Snow Leopard Server?

    - by morgant
    I've got a Mac Pro running Mac OS X 10.6.4 Snow Leopard Server and it's recently started getting numerous 'kNetworkError's in Server Admin.app when viewing services. It's acting as a gateway w/NAT and has been so for quite some time. There is one glaring issue, bootpd crashes all the time with the following errors in `/var/log/system.log/: Aug 12 16:54:59 servername bootpd[3572]: server starting Aug 12 16:54:59 servername bootpd[3572]: server name servername.domain.tld Aug 12 16:54:59 servername bootpd[3572]: interface en0: ip 10.0.1.9 mask 255.255.255.0 Aug 12 16:54:59 servername bootpd[3572]: bsdpd: re-reading configuration Aug 12 16:54:59 servername bootpd[3572]: bsdpd: shadow file size will be set to 48 megabytes Aug 12 16:54:59 servername bootpd[3572]: bsdpd: age time 00:15:00 Aug 12 16:54:59 servername bootpd[3572]: [3572] detected buffer overflow Aug 12 16:54:59 servername com.apple.launchd[1] (com.apple.bootpd[3572]): Job appears to have crashed: Abort trap Aug 12 16:54:59 servername com.apple.ReportCrash.Root[3571]: 2010-08-12 16:54:59.828 ReportCrash[3571:2807] Saved crash report for bootpd[3572] version ??? (???) to /Library/Logs/DiagnosticReports/bootpd_2010-08-12-165459_localhost.crash It is correctly configured to serve DHCP through en1 (not en0), the "LAN" port. This happens even with no hardware (even switches) connected to the "LAN" port. There are no DHCP clients listed. Oddly, the "Overview" shows 1 static map, but nothing is listed under "Static Maps" and there are no "Computers" in Open Directory. /var/db/dhcp_leases is empty. /Library/Logs/DiagnosticReports/bootpd_2010-08-12-165459_localhost.crash is as follows: Process: bootpd [3572] Path: /usr/libexec/bootpd Identifier: bootpd Version: ??? (???) Code Type: X86-64 (Native) Parent Process: launchd [1] Date/Time: 2010-08-12 16:54:59.713 -0400 OS Version: Mac OS X Server 10.6.4 (10F569) Report Version: 6 Exception Type: EXC_CRASH (SIGABRT) Exception Codes: 0x0000000000000000, 0x0000000000000000 Crashed Thread: 0 Dispatch queue: com.apple.main-thread Application Specific Information: __abort() called Thread 0 Crashed: Dispatch queue: com.apple.main-thread 0 libSystem.B.dylib 0x00007fff803c13d6 __kill + 10 1 libSystem.B.dylib 0x00007fff80461913 __abort + 103 2 libSystem.B.dylib 0x00007fff80456157 mach_msg_receive + 0 3 libSystem.B.dylib 0x00007fff803b92cf __strncpy_chk + 14 4 bootpd 0x0000000100014e5d PLCache_read + 782 5 bootpd 0x0000000100004a3d BSDPClients_init + 68 6 bootpd 0x00000001000053b5 bsdp_init + 2396 7 bootpd 0x000000010000200b S_update_services + 1228 8 bootpd 0x0000000100002344 S_server_loop + 571 9 bootpd 0x0000000100003963 main + 1766 10 bootpd 0x0000000100000984 start + 52 Thread 0 crashed with X86 Thread State (64-bit): rax: 0x0000000000000000 rbx: 0x00007fff5fbfe220 rcx: 0x00007fff5fbfe218 rdx: 0x0000000000000000 rdi: 0x0000000000000df4 rsi: 0x0000000000000006 rbp: 0x00007fff5fbfe240 rsp: 0x00007fff5fbfe218 r8: 0x0000000000000001 r9: 0x0000000100114280 r10: 0x00007fff803bd412 r11: 0xffffff80002e1680 r12: 0xffffffffffffffff r13: 0x00007fff5fbfe330 r14: 0x00007fff5fbfe33b r15: 0x00007fff7009bec0 rip: 0x00007fff803c13d6 rfl: 0x0000000000000202 cr2: 0x000000010004c000 Any thoughts or suggestions as to resolving this?

    Read the article

  • GPU not powering on

    - by Lerp
    So I got home from work yesterday and went to turn my computer on as per usual to be greeted by this: The screens remained black, so I rebooted; I go as far as GRUB before my screens went black again. I rebooted again, they didn't turn on. I rebooted again, I got as far as the windows login screen. This time I unplugged it, opened it up and cleaned it but to no luck. The GPU was still being tempermental. I repeated the process of turning off and on several times until one time it work as normal. I happily played games for the rest of the night (5-6 hours?) thinking everything was jolly good now. Well I get home from work today and it is doing the SAME thing. Sometimes everything displays normally for a few seconds to minutes then the screens go black; then sometimes the screens don't come on at all. Summary and additional points Screens sometimes turn on before shortly turning off, sometimes they don't; I cannot seem to determine any pattern between when they do or do not turn off. The build has been working fine for about 8 months now so I know it's not hardware incompatibility. If I plug a monitor into the on board graphics I can use the PC normally (just in low graphics mode) I have two monitors and it's a case of they both turn on or not. So I think I can rule out the monitors being dead. I have tried replacing the GPU I have tried replacing the RAM I have tried flashing the CMOS I have tried cleaning the inside The GPU is a Radeon HD 7870 My questions Is my GPU dead? It's not very old and I would rather have a method of being certain it's the GPU before I fork out some money I can't really afford. I do not have a second PC here to test it in. If my GPU is dead why does it sometimes work and sometimes not? Update Okay, it was working again.. at least I thought it was. I left it running for 10-20minutes with the screens black. Turned it off and straight back on and it worked for all of 10minutes. I was then updating the post in joy thinking I could play some games for the rest of the night when BAM it went black again. So yeah, I don't know :C

    Read the article

  • Can't get DHCPd to assign IPs to unknown clients

    - by Jakobud
    I'm using Webmin to admin our DHCPd server. But I'm having a hard time getting it to assign IP addresses to unknown clients. The only way I can get it to assign an IP is to make sure a host is added to DHCPd as a host so that it gets a static-lease IP assigned to it. I thought "Allow Unknown Clients" was the key, but it still isn't assigning IPs to unknown clients. I have a pool setup so that the unknown clients should get an IP between 10.20.0.200 - 10.20.0.249. Here is the config file. What am I missing here? allow unknown-clients; # Primary DHCP server config authoritative; ddns-update-style none; failover peer "dhcp-failover" { primary; address 10.20.0.30; port 647; peer address 10.20.0.25; peer port 647; max-response-delay 60; max-unacked-updates 10; load balance max seconds 3; mclt 3600; split 128; } subnet 10.20.0.0 netmask 255.255.255.0 { allow unknown-clients; option subnet-mask 255.255.255.0; option broadcast-address 10.20.0.255; option routers 10.20.0.100; option domain-name "ourdomain.com"; option domain-name-servers 192.168.10.20; default-lease-time 86400; max-lease-time 86400; option ntp-servers 192.168.10.20; option time-offset -25200; pool { allow unknown-clients; failover peer "dhcp-failover"; max-lease-time 86400; range 10.20.0.200 10.20.0.249; deny dynamic bootp clients; } host Server-myserver { option host-name "whatever.ourdomain.com"; hardware ethernet 00:89:D4:35:4F:13; fixed-address 10.20.0.23; } }

    Read the article

  • Transient network dropout for Xen DomU's

    - by Stephen C
    We've got a CentOS server running a cluster of virtuals. Occasionally the cluster's internal network drops out for a minute or so ... and then comes back. The problem is somehow related to the actual network traffic, but it is not a simple load issue. (The system is generally lightly loaded, and the problem occurs irrespective of actual load.) The setup: CentOS 5.6 on Dom0, various CentOS on the DomU's Hardware - a Dell R710 with a BroadCom NextXpress 2 NIC (sigh) using the latest drivers for the NIC from BroadCom Xen configured to use network-bridge and vif-bridge Some iptable tweaks to route an unrelated port to one of the virtuals. The system has one externally visible IP address, and Dom0 runs an Apache httpd configured with a number of virtual hosts each of which reverse proxies to web servers running on the virtuals. (The virtuals have to be NAT'ed, primarily because we don't have enough allocated public IP addresses.) The symptoms: Works fine most of the time. When someone tries to UPLOAD a large file to one virtuals, the internal network drops out ... for all virtuals: The Dom0 httpd sees a network timeout talking to the backend server on the virtual and reports a 502. A previously established ssh connection from Dom0 to any of the DomU's freezes. Our monitoring shows ping failures for traffic between virtuals. The Xen consoles to the DomU's do not freeze. No log messages in any log files that I can see, on either Dom0 or the DomU's ... apart from the Dom0 httpd logs. After a minute or so, the problem clears by itself. This is 100% reproducible. What we've tried: Downloading, building and installing the latest BNX2 driver on Dom0 Turning off MSI on the NIC - adding "options bnx2 disable_msi=1" to /etc/modprobe.conf Turning off tcp segmentation offload - "ethtool -K eth0 tso off". Sacrificing a black rooster at midnight. I've exhausted all my options apart from switching to KVM ... or slaughtering more roosters. Any suggestions?

    Read the article

  • Linux per-process resource limits - a deep Red Hat Mystery

    - by BobBanana
    I have my own multithreaded C program which scales in speed smoothly with the number of CPU cores.. I can run it with 1, 2, 3, etc threads and get linear speedup.. up to about 5.5x speed on a 6-core CPU on a Ubuntu Linux box. I had an opportunity to run the program on a very high end Sunfire x4450 with 4 quad-core Xeon processors, running Red Hat Enterprise Linux. I was eagerly anticipating seeing how fast the 16 cores could run my program with 16 threads.. But it runs at the same speed as just TWO threads! Much hair-pulling and debugging later, I see that my program really is creating all the threads, they really are running simultaneously, but the threads themselves are slower than they should be. 2 threads runs about 1.7x faster than 1, but 3, 4, 8, 10, 16 threads all run at just net 1.9x! I can see all the threads are running (not stalled or sleeping), they're just slow. To check that the HARDWARE wasn't at fault, I ran SIXTEEN copies of my program independently, simultaneously. They all ran at full speed. There really are 16 cores and they really do run at full speed and there really is enough RAM (in fact this machine has 64GB, and I only use 1GB per process). So, my question is if there's some OPERATING SYSTEM explanation, perhaps some per-process resource limit which automatically scales back thread scheduling to keep one process from hogging the machine. Clues are: My program does not access the disk or network. It's CPU limited. Its speed scales linearly on a single CPU box in Ubuntu Linux with a hexacore i7 for 1-6 threads. 6 threads is effectively 6x speedup. My program never runs faster than 2x speedup on this 16 core Sunfire Xeon box, for any number of threads from 2-16. Running 16 copies of my program single threaded runs perfectly, all 16 running at once at full speed. top shows 1600% of CPUs allocated. /proc/cpuinfo shows all 16 cores running at full 2.9GHz speed (not low frequency idle speed of 1.6GHz) There's 48GB of RAM free, it is not swapping. What's happening? Is there some process CPU limit policy? How could I measure it if so? What else could explain this behavior? Thanks for your ideas to solve this, the Great Xeon Slowdown Mystery of 2010!

    Read the article

  • EMC/Legato/Networker Failed to recover files : Cross Platform Recovery not supported.

    - by marc.riera
    Software used to backup: EMC / Legato Networker legato server : windows legato clients: same hardware (2 years ago fedora something , now ubuntu ) Trying to recover from an old client, which is no longer available. So this is the thing. On 07/20/2008 we backed up a samba server(fedora something) to a tape , setting 1 year as browse policy and retention policy. Now this tape is recyclable. We took down the dns name. We deleted the legato client configuration. That legato client was reinstalled and is doing other stuff on ubuntu 10.04, with a different name but same ip. Now, 2 years and some month later #### Now we need to recover a folder from 2008 backup, on the fedora-samba-server. First thing, legato does not show the client name because the config was deleted. We create it again. We just set the old dns back on track, pointing the same ip, where the old server was, same MAC address ;). We created a new 'old client configuration' pointing to the new server. (different legato ip for client "I suppose" ) The ssid where the needed folder is on 2 tapes, 20 and 22. The index for that backup is on tape 21. We put this tapes on the jukebox (IBMT4000) -- not important for the issue -- All three tapes expired its browsable and recoverable time. So they are on recyclable. We get the clone id from the ssid with following command: mminfo -avot -q "ssid=<ssid>" -r cloneid We set the tapes to notrecyclable nsrmm -S <ssid>/<cloneid> -o notrecyclable We change the retention for the tapes for a future date nsrmm -S <ssid> -e 01/20/2011 We check the dates are correct : mminf -avV -q "ssid=<ssid>" -r ssbrowse(26),ssretent(26),savetime So far its OK. We close the terminal. Restart the server, just for being sure. Finally, we recover the index for that ssid where the folder should be. nsrck -L7 -t "07/20/2008" oldservername.domain.org There, we open the Networker User, select the server, select the old client as source, select the new client as destination. And this is what I get. imgur image of output -- http://i.imgur.com/1nOr8.png Should I understand that I need to install whatsoever operating system that was running on the old "linux server"/"networker client" to be able to restore 26Mb of files? thanks

    Read the article

  • MBPro, mid 2010 can't see Dlink DIR655 signal after sleep etc

    - by user88114
    This is my son's MBP 7,1 running Snow Leopard 10.6.7. Router signal is fine since iPad, Wintel on same table 20 feet from router are fine. the MBP however frequently wakes and fails to find the internet. iStumbler can see 1 neighbours hub and my garden hub are there but can't get to the normal DIR655 wifi... no ping no en0 or en1 device seems to exist. Airport off and on does not help. He just resets router and it all works but this does not please me! I must admit the winter sometimes seems to loose connect too, but less so. The DIR655 (hardware rev A3) is on the original EU firmware 1.10, I'm cautious about jumping to latest 1.31EU since no downgrade seems to be possible and that feels a bit risky as so much is set up and working fine. If I use the DIR655 admin web and release the lease the MBP has then wake it all worked OK. So I suspect lease timing/locking issue but unsure how to check up, plus why iStumbler seems to say the network is not visible at all when I sit on the iPad right next to it just fine.. I do not think there are any channel overlaps and we also have RFquiet DECT phones (Orchid) that are silent until lifted or called. Anyway signals all show low interference and high throughput except for this failure to connect. Just walked the MBP to the garden office and iStumbler now sees the more distant DIR655 signal although it will not connect to it (does not show under Sys Prefs NetNetwork names) even after airport off & on... It also refuses to connect to my garden network (an old Belkin acting as AP wired to DIR655), the signal it can see and even net name in Sys Prefs NetNetwork names (2 mins later):NOW both names ARE visible, but both fail to accept the correct WPA2 password and keep asking again after failing to connect. IT ALL MAKES NO SENSE TO ME. Just revoked the lease for the MBP on DIR655 and no changes although this seemed to help MBP wake into connection 1 hour ago. OK a bit of walking about to report. Carried MBP across garden towards DIR655, a few other wifis show up on iStumbler, low signals all channel 1. Right next to DIR655 but iStumbler not showing it, although most other wifi's have gone. I'd say iStubler is suffering timeouts&hangs but hard to be sure. Lots of attempts to Airport on/off, join other etc and suddenly I get to connect, get given new IP (I revoked), can browse. Walk away, connection drops quite soon at 30 feet then reconnected briefly then died again. MUST ATTEND ELSEWHERE FOR A BIT...

    Read the article

  • OpenVPN multiple servers on the same subnet, high availability

    - by andre
    Hey everyone. Let me start by saying that my Linux experience isn't super awesome but I can usually find my way around things easily. Over at work we have an OpenVPN setup that's been due for some improvement for a while now. The main server (tap mode) runs in our office, behind a rather slow DSL connection. The main problem is that, since I'm usually out of the office, every time I want to access something on the virtual network I have to go through that server to get anywhere else. We have two servers up on 100 Mbit connections that we use for development and production purposes, about 3 more servers in the office (one of them behind a different T1 line for VOIP) and about two dozen clients who use the network on a daily basis from various locations. We've had situations where network routing (outside of our control) would not allow people to reach our main OpenVPN server whilst the other locations were connectable. Also any time someone outside the office wants to fetch something from any of the servers (say, a 500 MB code repository), a whopping 20 KB/s download speed is just unacceptable these days (did I mention slow DSL? ok). We had to implement traffic shaping on this server since maxing out this connection was fairly trivial. I had the thought of running two (or more) OpenVPN servers in the network. These would have to have the same subnet though, as our application relies on virtual network's IP addresses for some of its core functionality. The clients would also preferably retain the same IP addresses but that's not vital. For simplicity, lets call the current server office and the second server I'm setting up, cloud. Call the server on the T1 phone. This proved to be rather complex because as soon as I connect to cloud, I cannot see office. Any routes to a server that would go through office also do not work while I'm connected to cloud (no ping, nothing) and vice-versa. There's no rules for iptables that would be blocking the traffic either. Recently I came across this article on linuxjournal but the solution they provide seems to only cover the use of two servers and somewhat outdated (can't even find much documentation, their wiki is offline). They also state that adding more servers would be a complex task. Ideally I would like to keep the existing server office running the virtual network and also run the OpenVPN daemon on the cloud and phone servers (100 Mbit and very reliable connection, respectively) so that we're on safe ground in case of a hardware failure, DSL failure, etc. So, in essence, I'm looking for a highly available OpenVPN solution (fix, patch, hack, tweak, whatever you want to call it) that will accept connections on multiple hosts (2 or more) whilst keeping the same IP address subnet regardless of the server to which you connect to. Thanks for reading and sorry for the long post, I hope it gets the point across :P

    Read the article

  • Bluetooth not detecting any devices in Windows 7

    - by underDog
    My Lenovo ThinkPad E320 Laptop running Windows 7 64bit has recently been refusing to detect any Bluetooth devices. I have tried to connect, using 'Add devices' under 'devices and printers' to two different Bluetooth mice and my HTC Wildfire android (2.2.1) phone and none of them are detected in the 'Add a device' dialog. History - Bluetooth initially seemed OK when I first got this laptop. I was able to connect to and use my android phone as a remote with no issues. I got my first Bluetooth mouse, it paired, but after each restart, or even after sleeping, it would not 're-connect' (even though it was listed under Bluetooth devices and supposedly 'working'), and I would need to remove the device and add it again. A week or two ago it stopped working all together. It is not detected at all. I gave up on the mouse and bought another (Lenovo ThinkPad brand) only to find that it was not detected either. I subsequently tested my Android phone and discovered it would not detect either. One thing of note is under 'Devices and Printers' there is listed a 'HID Keyboard Device' which under properties is listed as a 'Bluetooth HID Device'. This was not previously there before this problem started. Each time I remove it, or uninstall it from Device Manager it will quickly re-install itself, even with all my Bluetooth devices switched off. My (Google and searching this site) research of this issue has not yielded any definitive answers. I have changed the setting under Device Manager - Bluetooth - Properties - Power Management - 'Allow the computer to turn off this device to save power' to off. I have attempted to un-install and re-install the Bluetooth hardware, including the 'remove drivers' option and downloading and running the Lenovo Bluetooth installer package (found @ http://support.lenovo.com/en_US/downloads/detail.page?DocID=DS014997). Bluetooth is turned on. All items under Bluetooth properties (Discovery and Connections) are checked. I have tried changing the batteries. I'm not sure what else I can try, apart from perhaps doing a fresh install of Windows. Any suggestions?

    Read the article

  • Can't validate mine, sudo nor root in Debian "Jessie" Gnome anymore?

    - by Janar
    I'm Debian beginner & GUI guy in a bit of trouble? Can't login as sudo/gksu/root/su nor as (main/super)user after removed user password via Gnome-user-settings. History of actions (Probably irrelevant though) Installed Debian "Jessie" GNU/Linux with xFce GUI (en-US) as only OS. HardWare is ThinkPad w510. Skipped root user password in setup, to get sudo for superuser easily. Logged in (as always had) with Gnome (3.4.x), not once with xFCE. (installed Xfce. Installed xFce only to achieve more control (easier management) over packages this way, to set-up gnome much more by mine likes. Added more jessie repros (same ones as in Wheesy stable by default but for Jessie as, Jessie only had repros for security updates by default). Installed lots of gtk(3) & gnome(3) based soft; (- restarted again after this) Installed propietary graphics card driver for mine nvidia quadro. (- restarted once again after that one) Installed more stuff related to mine work/school/devel. The actual problem Had a plan to restart again, but wanted to set up auto-login first, instead set user password to none (don't ask why / perhaps caused by being awake for a looooong time), noticed it, and set also to auto-login, but couldn't undo mine previous mistake to create new password for me. As mine password is set to none I would have expected that simply return in pass prompt for emty password field would do, but it won't authenticate. I tried Alt+F2 "gksu gedit" as well as: sudo wget "https://www.some-page.eu/file.ext" and "su" in terminals, none has applied (quite logical actually - as I'm sudoer and highest ranked super user, besides only user in computer). Current stand Everything worked & still works nice after this accident, besides this password prompts part. To spoked to log-out nor restart. Synaptic package-manager is still open with root rights (only one, that has left open prior to the issue and not closed since, just in case). Goggled for help and read some manuals/faqs/how-tos - mostly lead to sudoers file management, but not found one specifically for mine issue - so still not any smarter. Really hope, that I don't have to redo OS inst all over again, by just one stupid mistake. Thanks for your reply :-)

    Read the article

  • Ubuntu getting wrong hostname from DHCP

    - by sam
    When provisioning new Ubuntu Precise (12.04) servers, the hostname they're getting seems to be generated from the DNS search path, not a reverse lookup on the hostname. Take the following configuration BIND is configured with the hostname, and reverse name Normal zone $TTL 600 $ORIGIN srv.local.net. @ IN SOA ns0.local.net. hostmaster.local.net. ( 2014082101 10800 3600 604800 600 ) @ IN NS ns0.local.net. @ IN MX 5 mail.local.net. my-new-server IN A 10.32.2.30 And reverse @ IN SOA ns0.local.net. hostmaster.local.net. ( 2014082101 10800 3600 604800 600 ) @ IN NS ns0.local.net. $ORIGIN 32.10.in-addr.arpa. 30.2 IN PTR my-new-server.srv.local.net. Then DHCPD is configured to hand out static leases based on mac addresses like so subnet 10.32.2.0 netmask 255.255.254.0 { option subnet-mask 255.255.254.0; option routers 10.32.2.1; option domain-name-servers 10.32.2.1; option domain-name "util.of1.local.net of1.local.net srv.local.net"; site-option-space "pxelinux"; option pxelinux.magic f1:00:74:7e; if exists dhcp-parameter-request-list { option dhcp-parameter-request-list = concat(option dhcp-parameter-request-list,d0,d1,d2,d3); } group { option pxelinux.configfile "pxelinux.cfg/pxeboot"; host my-new-server { fixed-address my-new-server.srv.local.net; hardware ethernet aa:aa:aa:bb:bb:bb; } } } So the hostname should be my-new-server.srv.local.net, however when building a Ubuntu 12.04 node, the hostname ends up as my-new-server.util.of1.local.net When building Lucid (10.04) hosts, the hostname will be correct, it's only on Precise/12.04 nodes we have the problem. Doing a normal and reverse lookup on the host and IP returns the correct result Sams-MacBook-Pro:~ sam$ host my-new-server my-new-server.srv.local.net has address 10.32.2.30 Sams-MacBook-Pro:~ sam$ host my-new-server.srv.local.net my-new-server.srv.local.net has address 10.32.2.30 Sams-MacBook-Pro:~ sam$ host 10.32.2.30 30.2.32.10.in-addr.arpa domain name pointer my-new-server.srv.local.net. The contents of the hosts file is incorrect too 127.0.0.1 localhost 127.0.1.1 my-new-server.util.of1.local.net of1.local.net srv.local.net my-new-server So it looks like when it creates the hosts file, it puts the entire contents of the DNS search path into the local address so the FQDN according to the server is the short hostname as defined, then the first domain in the search path. Is there a way to get around this behaviour, or fix this so it gets the hostname correctly? It's picking up the first part of the hostname, then the rest is wrong.

    Read the article

  • XCP Project Kronos syslog error: "irq ... : nobody cared" on Dom0 host

    - by Vlad Fedin
    One of our production clusters driven by XCP suddenly went uresponsive. After restart and some investigation we found such logs in dom0 machine syslog: Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659040] irq 339: nobody cared (try booting with the "irqpoll" option) Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659058] Pid: 0, comm: swapper/3 Tainted: G C O 3.2.0-24-generic #37-Ubuntu Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659060] Call Trace: Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659062] <IRQ> [<ffffffff810db37d>] __report_bad_irq+0x3d/0xe0 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659071] [<ffffffff810db605>] note_interrupt+0x135/0x190 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659074] [<ffffffff810d8e69>] handle_irq_event_percpu+0xa9/0x220 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659078] [<ffffffff8130ff3b>] ? radix_tree_lookup+0xb/0x10 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659081] [<ffffffff810d9031>] handle_irq_event+0x51/0x80 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659084] [<ffffffff810dc187>] handle_edge_irq+0x87/0x140 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659089] [<ffffffff813a8829>] __xen_evtchn_do_upcall+0x199/0x250 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659092] [<ffffffff813aa96f>] xen_evtchn_do_upcall+0x2f/0x50 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659096] [<ffffffff81666d3e>] xen_do_hypervisor_callback+0x1e/0x30 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659097] <EOI> [<ffffffff810013aa>] ? hypercall_page+0x3aa/0x1000 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659104] [<ffffffff810013aa>] ? hypercall_page+0x3aa/0x1000 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659107] [<ffffffff8100a1d0>] ? xen_safe_halt+0x10/0x20 Oct 26 20:32:03 hetzner-2-mrx kernel: [1797931.659110] [<fff IRQ 339 in cat /proc/interrupts: 339: ... xen-pirq-msi-x eth0 where eth0 is hardware NIC. While host machine seems to hang, guest machines continue to work, so our tiny internal monitoring on one of the virtual hosts logged something like that: [2012-10-26 20:31:51] [OK......] 200 OK : 113159149 ns [2012-10-26 20:32:40] [DISASTER] 500 Can't connect to [hostname]:80 (No route to host) : 47763284432 ns ... [2012-10-26 20:34:40] [DISASTER] 500 Can't connect to [hostname]:80 (No route to host) : 46894835070 ns [2012-10-26 20:34:57] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 16821741955 ns ... [2012-10-26 20:38:18] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 20103298289 ns [2012-10-26 20:38:37] [DISASTER] 500 Can't connect to [hostname]:80 (Bad hostname) : 17895754943 ns Host and guest OS: Ubuntu 12.04 LTS, 05:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection Subsystem: ASUSTeK Computer Inc. Device 8369 Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx+ Latency: 0, Cache Line Size: 64 bytes Interrupt: pin A routed to IRQ 17 Region 0: Memory at fe500000 (32-bit, non-prefetchable) [size=128K] Region 2: I/O ports at e000 [size=32] Region 3: Memory at fe520000 (32-bit, non-prefetchable) [size=16K] Capabilities: <access denied> Kernel driver in use: e1000e Kernel modules: e1000e Any hints how to debug this?

    Read the article

  • Thinkpad speaker turns mute - Linux Codec issue?

    - by Curlew
    At some point a few days ago the speakers on my Lenovo Thinkpad T410 (Model number: 2537A11) suddenly stopped working randomly. This error happens every time I watch a video or listen to a music file. The sound just abruptly stops. At the moment, I can't produce a single sound no matter what I do. I am using Debian GNU/Linux on this laptop and there doesn't appear to be anything else wrong (the fan is working, no abnormal heat (staying around ~40°C), no other obvious errors or problems). Here is the output of a nice program someone pointed me to: martin@martin:~/Downloads$ sudo python run.py --monitor Using temporary directory: /dev/shm/hda-analyzer You may remove this directory when finished or if you like to download the most recent copy of hda-analyzer tool. Downloading file hda_analyzer.py Downloading file hda_guilib.py Downloading file hda_codec.py Downloading file hda_proc.py Downloading file hda_graph.py Downloading file hda_mixer.py Downloaded all files, executing hda_analyzer.py Watching 1 cards ====================================== Sound is working normally and then it stops and the following lines appear: Diff for codec 0/0 (0x14f15069): --- +++ @@ -164,17 +164,17 @@ Power: setting=D0, actual=D0 Node 0x1f [Pin Complex] wcaps 0x400501: Stereo Pincap 0x00000010: OUT Pin Default 0x901701f0: [Fixed] Speaker at Int N/A Conn = Analog, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT - Power: setting=D0, actual=D0 + Power: setting=D3, actual=D3 Connection: 2 0x10* 0x11 Node 0x20 [Pin Complex] wcaps 0x400781: Stereo Digital Pincap 0x00000010: OUT Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE And now there is also an error in the dmesg output hda-intel: IRQ timing workaround is activated for card #0. Suggest a bigger bdl_pos_adj. I changed the bdl_pos_adj to various numbers (-1, 0, 64, 1024) and either there is no change at all or dmesg reports that the adjustment is too big. I wonder if this bdl_pos_adj is the real reason for the error. Here is my hardware information provided by alsa-info.sh website. Okay, i did some serious testing and even installed Windows and now i officially conclude that this is a hard-ware related issue with my Laptop speakers. Reason: The error occurs in my installed Debian Linux, an Ubuntu Live distribution and Windows XP No error-message appears in all of the OS. The sound just keeps running and i can't hear a thing. I tested different setups, including OSS, ALSA and the pulseaudio server on top If i use my new usb-headphones i can hear sound all the time without any sudden silences. So obviously, although hard to believe, my laptop speakers are not okay (never heard of similar cases). I'll award the bounty to anyone who can point me to good tutorials or the procedure how to exchange my T410 speakers (i still have warranty. The laptop was bought in Germany, but now i am in Denmark). Or to someone who can explain me the output from hda-analyzer (big log above).

    Read the article

  • Triple (3) Monitors under Linux

    - by widgisoft
    I have a 3 monitor setup (each 1680x1050) via an Nvidia NVS440 (2 GPUs, 2 outputs per GPU totalling 4 outputs); this works fine under Windows XP,7 but caused considerable headaches under Linux (Ubuntu 9.04). I had previously used an XFX 9600GT and the onboard XFX 9300GS to produce the same result but the card was noisy and power hungry and I was hoping that there was some magical switch in the NVS4400 that got rid of this annoying problem - turns out the NVS440 is just 2 cards on one physical PCB :-p (I searched the net high and low for people using this card under Linux but found nothing, if anything the card uses less power and is fan less so I was to benefit from it either way) Anyway, using either set up there were 5 solutions available: Have 3 separate X instances, all un joined Have 3 separate X instances, adjoined by Xinerama Have 2 separate X instances - One using twin-view, both adjoined by Xinerama Have 2 separate X instances - One using twin-view but no Xinerama Have a single Twin-view setup and leave the 3rd screen unplugged :-p The 4rd option, using 2 separate X instances and twinview (but no xinerama) was the best balance in terms of performance and usability but caused 2 really annoying issues You couldn't control (without altering the shortcuts) which screen an application opened onto - and once it was opened you couldn't move it to another screen without opening up terminal and forcing it to move Nvidia's overriding or falsifying of Xinerama breaks and the 2 screens joined by Twin view behave like a single huge screen causing popups to open in the middle of both screens and maximising of windows stretches to the width of the first 2 screens Firefox can only run one instance as the same user so having multiple firefox windows requires at least 2 users The second option "feels" like the right option, but OpenGL is basically disabled and playing any sort of game or even running anything graphical causes a huge performance drop and instability - even trying to run a basic emulator for gba or gens just causes the system to fall over. It works just enough to stare at your desktop and do nothing but as soon as you start doing some work - opening windows, dragging things around - running multiple copies of firefox it just really feels slow. The last open, only going dual screen works perfectly and everything performs as required, full GPU acceleration - two logical screen spaces - perfect, just make it work across GPUs like windows! :-p Anyway, I know RandR was supposed to pick up the slack when it would introduced GPU objects of sorts to allow multiple GPUs to be stitched together to create one huge desktop at a much deeper layer than Xinerama. I was wondering if this has now been fixed (I noticed X server 1.7 is out) and whether anyone has got it running successfully? Again, my requirements are: One huge desktop to drag any window across Maximising of windows to each screen (as XP does) Running fullscreen apps on the primary screen and disabling the mouse from moving onto the others or on all 3 stretched Finally as a side note; I am aware of the Matrox triple (and dual) head splitter but even the price they go for on eBay is more than I can afford atm, my argument: I shouldn't have to buy extra hardware to get something to work on Linux when it's something that's existed in the windows world for a long time (can you tell I don't get on with X :-p); If I had the cash I'd have bought the latest version of this box already (the new version finally supports large resolutions as the displays I have 1680x1050 each).

    Read the article

  • SQL Clustering on Hyper V - is a cluster within a cluster a benefit.

    - by Chris W
    This is a re-hash of a question I asked a while back - after a consultant has come in firing ideas in to other teams in the department the whole issue has been raised again hence I'm looking for more detailed answers. We're intending to set-up a multi-instance SQL Cluster across a number of physical blades which will run a variety of different systems across each SQL instance. In general use there will be one virtual SQL instance running on each VM host. Again, in general operation each VM host will run on a dedicated underlying blade. The set-up should give us lots of flexibility for maintenance of any individual VM or underlying blade with all the SQL instances able to fail over as required. My original plan had been to do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Within the VMs - create a failover cluster and then install SQL Server clustering. The consultant has suggested that we instead do the following: Install 2008 R2 on each blade Add Hyper V to each blade Install a 2008 R2 VM to each blade Create a cluster on the HOST machines which will host all the VMs. Within the VMs - create a failover cluster and then install SQL Server clustering. The big difference is the addition of step 4 whereby we cluster all of the guest VMs as well. The argument is that it improves maintenance further since we have no ties at all between the SQL cluster and physical hardware. We can in theory live migrate the guest VMs around the hosts without affecting the SQL cluster at all so we for routine maintenance physical blades we move the SQL cluster around without interruption and without needing to failover. It sounds like a nice idea but I've not come across anything on the internet where people say they've done this and it works OK. Can I actually do the live migrations of the guests without the SQL Cluster hosted within them getting upset? Does anyone have any experience of this set up, good or bad? Are there some pros and cons that I've not considered? I appreciate that mirroring is also a valuable option to consider - in this case we're favouring clustering since it will do the whole of each instance and we have a good number of databases. Some DBs are for lumbering 3rd party systems that may not even work kindly with mirroring (and my understanding of clustering is that fail overs are completely transparent to the clients). Thanks.

    Read the article

  • Windows 2003 Storage Server Hanging on Large File Transfers

    - by user25272
    In one of our offices we have a Dell PowerVault 745N NAS device which acts as the main file server. Its running 32bit Windows 2003 Storage Server SP2 with 3GB RAM. The server holds around 60 users HOME folders, which are mapped via AD. The office clients are a mix of XP SP3, Vista and Windows 7. Occasionally the server will completely hang when transferring large files. When the hang happens the console becomes unresponsive with only the mouse active and blank wallpaper. Sometimes stopping the copy frees the server, sometimes not. The hanging can last around 20 minutes. During this time other servers also become unresponsive with blank wallpaper at the console. If you do manage to get onto another server the taskbar and run commands are unresponsive. This also transcends to the client computers sometimes with explorer crashing. I'm guessing this is due to the HOME folder mapping. Eventually the NAS server with free up and everything will be back to normal. The server is configured as follows: PERC 4/DC DATA 2 - 12 SCSI HDD - RAID5 SHADOWCOPY 2 SCSI HDD - RAID1 CERC SATA DATA 11 4 SATA HDD - RAID5 OS 4 SATA HDD - RAID5 All the drivers and firmware is up to date. I've been through all the diagnostics with Dell and the hardware has come up clean including full HDD tests on the arrays. The server has NOD32 installed as the AV, but the hanging happens when it is uninstalled. There are no errors in the event log when this happens and we don't have any errors logged on any of our ProCurve switches. DNS is fine on the domain and AD from what I can tell is running happily. There are no DFS or NFS shares setup either. All the shares are standard Windows. I've unchecked the allow the computer to turn off this device to save power box under Power Management on the NIC. "Set Link Speed and Duplex to Auto-negotiate 1000 " Increased Receive Descriptors buffer from 256 to 352 (reserves more CPU resource for handling data) I've run network traces using network monitor and have found the following: 417 8.078125 {SMB:192, NbtSS:25, TCP:24, IPv4:23} 192.168.2.244 192.168.5.35 SMB SMB:R; Nt Create Andx - NT Status: System - Error, Code = (52) STATUS_OBJECT_NAME_NOT_FOUND I've tried different cabling; NICs and switch ports all with the same result. Transferring files from other servers on the domain is fine. All I haven't done is run CHKDSK on the drives to look for any file system errors. On the Vista clients I have also run netsh interface tcp set global autotuning=disabled with no result. Could it be that the server has a faulty drive or that the I/O is too much for it to handle? Any ideas why would the hang cause issues with the other servers on the LAN? Many Thanks.

    Read the article

  • Problem with USB drivers (Windows-XP)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Should use EXT4 or XFS to be able to 'sync'/backup to S3?

    - by Rafa
    It's my first message here, so bear with me... (I have already checked quite a few of the "Related Questions" suggested by the editor) Here's the setup, a brand new dedicated server (8GB RAM, some 140+ GB disk, Raid 1 via HW controller, 15000 RPM) it's a production web server (with MySQL in it, too, not just serving web requests); not a personal desktop computer or similar. Ubuntu Server 64bit 10.04 LTS We have an Amazon EC2+EBS setup with the EBS volume formatted as XFS for easily taking snapshots to S3, via AWS' console. We are now migrating to the dedicated server and I want to be able to backup our data to Amazon's S3. The main reason being the possibility of using the latest snapshot from an EC2 instance in case of hardware failure on the dedicated server. There are two approaches I am thinking of: do a "simple" file-based backup with rsync, dumping the database' and other files, and uploading to amazon via S3 API commands, or to an EC2 instance, or something. do a file-system "freeze" (using XFS) with the usual ebs/ec2 snapshot tool to take part of the file system, take a snapshot, and upload it to Amazon. Here's my question (or series of questions): Can I safely use XFS for the whole system as the main and only format on the dedicated server? If not, is it safe to use EXT4? Or should I use something else? would then be possible to make snapshots of the system to upload to Amazon? Is it possible/feasible/practical to do what I want to do, anyway? any recommendations? When searching around for S3/EBS/XFS, anything relevant to my problem is usually focused on taking snapshots of a XFS system that is already an EBS volume. My intention is to do it in a "real"/metal dedicated server. Update: I just saw this on Wikipedia: XFS does not provide direct support for snapshots, as it expects the snapshot process to be implemented by the volume manager. I had always assumed that I could choose 2 ways of doing snapshots: via LVM or via XFS (without LVM). After reading this, I realize these 2 options are more like it: With XFS: 1) do xfs_freeze; 2) copy the frozen files via, eg, rsync; 3) unfreeze xfs With LVM and XFS: 1) do xfs_freeze; 2) make a binary copy of the frozen fs via lvcreate and related commands; 3) unfreeze xfs; 4) somehow backup the LVM snapshot. Thanks a lot in advance, Let me know if I need to clarify something.

    Read the article

  • Spotlight Infinite Indexing issue (external data drive)

    - by Manca Weeks
    This is an external drive, formerly a boot drive which is now in use only to access music files (sibelius, audio, midi, live, logic etc.) without transferring the data into a new boot system, partly because of the issue I am about to describe, but mostly because the majority of the data is mainly there for archival purposes. The user is a composer and prominent musician and needs to be able to rehash the data at will. I have tried several things - here is a list: - make complete filesystem clone with antonio diaz's ddrescue - run Disk Warrior on copy, repair whatever errors occurred - wipe out all ACLs on entire drive - set all permissions to the same value - wide open 777 - remove any system data (applications, system files, including hidden files to the best of my knowledge) by selecting only non-system/app data and using Carbon Copy Cloner to put only the data of interest onto a newly formatted drive - transfer data to newly formatted drive folder by folder, resetting the spotlight index in between adding each to observe for issues (interesting here is that no issues occurred except for in Documents folder - when I transferred only the Documents folder to a newly formatted drive on its own - no trouble. It appears almost as thought it may not be the content but the quantity or specific combination of data that results in problems) - use DataRescue to transfer the data to yet another newly formatted drive to expose any missed hidden files Between each of the above steps I stopped Spotlight (search for anything beginning with md in Activity Monitor - All Processes and quitting it), deleted the .Spotlight-V100 directory from the affected drive. Restart Splotlight indexing by adding drive to Spotlight privacy list and removing it. In each case the same issue occurs - Spotlight begins indexing normally (or so it seems), then the index estimated time increases, usually to 4 hours remaining. This is where it gets stuck and continues to predict 4 hours remaining but never finishes. Sometimes I can't eject the drive and have to quit the md.. processes from Activity Monitor to be able to eject the drive without Force Eject. Once I disconnect the drive after the 4 hours remaining situation - if I reattach it, Spotlight forever estimates remaining time and never gets going again. So there it is. It is apparently not a filesystem issue, not a permissions issue and not tied to any particular piece of hardware or protocol (used USB and FW drives). I have tried this on several machines (3 to be precise) and in 10.5.8 and 10.6.5. Simply disabling Spotlight on this volume is not an option because the owner has no clue where things are as the data on the volume dates back to music projects and compositions from 2003 and before. He needs to be able to query for results. Anyone got any ideas? Thanks, M

    Read the article

< Previous Page | 312 313 314 315 316 317 318 319 320 321 322 323  | Next Page >