Search Results

Search found 14345 results on 574 pages for 'hamiltonian path'.

Page 329/574 | < Previous Page | 325 326 327 328 329 330 331 332 333 334 335 336  | Next Page >

  • CentOS - PHP - Yum Install with Custom ./configure params

    - by Mike Purcell
    I have successfully configured and compiled php on my dev server, and works great, but after talking to a sysadmin buddy, he informed that custom compiles of the latest builds are not recommended for production (or even development) systems. He noted a situation where they custom configured and compiled PHP 5.3.6, only to find that there was some issue with a low-level Postgres driver, so they had to revert back to 5.3.3. So I am considering going back to yum to install PHP, however I have several custom configuration settings and was wondering if it's possible to pass or configure how PHP will be compiled through YUM? My current configure line: Configure Command => './configure' '--with-libdir=lib64' '--prefix=/usr/local/_custom/app/php' '--with-config-file-path=/usr/local/_custom/app/php/etc' '--with-config-file-scan-dir=/usr/local/_custom/app/php/etc/modules' '--disable-all' '--with-apxs2=/usr/sbin/apxs' '--with-curl=/usr/sbin/curl' '--with-gd' '--with-iconv' '--with-jpeg-dir=/usr/lib' '--with-mcrypt=/usr/bin' '--with-pcre-regex' '--with-pdo-mysql=mysqlnd' '--with-png-dir=/usr/lib' '--with-zlib' '--enable-ctype' '--enable-dom' '--enable-hash' '--enable-json' '--enable-libxml' '--enable-mbstring' '--enable-mbregex' '--enable-pdo' '--enable-session' '--enable-simplexml' '--enable-xml' '--enable-xmlreader' '--enable-xmlwriter'

    Read the article

  • Click Once Deployment Process and Issue Resolution

    - by Geordie
    Introduction We are adopting Click Once as a deployment standard for Thick .Net application clients.  The latest version of this tool has matured it to a point where it can be used in an enterprise environment.  This guide will identify how to use Click Once deployment and promote code trough the dev, test and production environments. Why Use Click Once over SCCM If we already use SCCM why add Click Once to the deployment options.  The advantages of Click Once are their ability to update the code in a single location and have the update flow automatically down to the user community.  There have been challenges in the past with getting configuration updates to download but these can now be achieved.  With SCCM you can do the same thing but it then needs to be packages and pushed out to users.  Each time a new user is added to an application, time needs to be spent by an administrator, to push out any required application packages.  With Click Once the user would go to a web link and the application and pre requisites will automatically get installed. New Deployment Steps Overview The deployment in an enterprise environment includes several steps as the solution moves through the development life cycle before being released into production.  To make mitigate risk during the release phase, it is important to ensure the solution is not deployed directly into production from the development tools.  Although this is the easiest path, it can introduce untested code into production and result in unexpected results. 1. Deploy the client application to a development web server using Visual Studio 2008 Click Once deployment tools.  Once potential production versions of the solution are being generated, ensure the production install URL is specified when deploying code from Visual Studio.  (For details see ‘Deploying Click Once Code from Visual Studio’) 2. xCopy the code to the test server.  Run the MageUI tool to update the URLs, signing and version numbers to match the test server. (For details see ‘Moving Click Once Code to a new Server without using Visual Studio’) 3. xCopy the code to the production server.  Run the MageUI tool to update the URLs, signing and version numbers to match the production server. The certificate used to sign the code should be provided by a certificate authority that will be trusted by the client machines.  Finally make sure the setup.exe contains the production install URL.  If not redeploy the solution from Visual Studio to the dev environment specifying the production install URL.  Then xcopy the install.exe file from dev to production.  (For details see ‘Moving Click Once Code to a new Server without using Visual Studio’) Detailed Deployment Steps Deploying Click Once Code From Visual Studio Open Visual Studio and create a new WinForms or WPF project.   In the solution explorer right click on the project and select ‘Publish’ in the context menu.   The ‘Publish Wizard’ will start.  Enter the development deployment path.  This could be a local directory or web site.  When first publishing the solution set this to a development web site and Visual basic will create a site with an install.htm page.  Click Next.  Select weather the application will be available both online and offline. Then click Finish. Once the initial deployment is completed, republish the solution this time mapping to the directory that holds the code that was just published.  This time the Publish Wizard contains and additional option.   The setup.exe file that is created has the install URL hardcoded in it.  It is this screen that allows you to specify the URL to use.  At some point a setup.exe file must be generated for production.  Enter the production URL and deploy the solution to the dev folder.  This file can then be saved for latter use in deployment to production.  During development this URL should be pointing to development site to avoid accidently installing the production application. Visual studio will publish the application to the desired location in the process it will create an anonymous ‘pfx’ certificate to sign the deployment configuration files.  A production certificate should be acquired in preparation for deployment to production.   Directory structure created by Visual Studio     Application files created by Visual Studio   Development web site (install.htm) created by Visual Studio Migrating Click Once Code to a new Server without using Visual Studio To migrate the Click Once application code to a new server, a tool called MageUI is needed to modify the .application and .manifest files.  The MageUI tool is usually located – ‘C:\Program Files\Microsoft SDKs\Windows\v6.0A\Bin’ folder or can be downloaded from the web. When deploying to a new environment copy all files in the project folder to the new server.  In this case the ‘ClickOnceSample’ folder and contents.  The old application versions can be deleted, in this case ‘ClickOnceSample_1_0_0_0’ and ‘ClickOnceSample_1_0_0_1’.  Open IIS Manager and create a virtual directory that points to the project folder.  Also make the publish.htm the default web page.   Run the ManeUI tool and then open the .application file in the root project folder (in this case in the ‘ClickOnceSample’ folder). Click on the Deployment Options in the left hand list and update the URL to the new server URL and save the changes.   When MageUI tries to save the file it will prompt for the file to be signed.   This step cannot be bypassed if you want the Click Once deployment to work from a web site.  The easiest solution to this for test is to use the auto generated certificate that Visual Studio created for the project.  This certificate can be found with the project source code.   To save time go to File>Preferences and configure the ‘Use default signing certificate’ fields.   Future deployments will only require application files to be transferred to the new server.  The only difference is then updating the .application file the ‘Version’ must be updated to match the new version and the ‘Application Reference’ has to be update to point to the new .manifest file.     Updating the Configuration File of a Click Once Deployment Package without using Visual Studio When an update to the configuration file is required, modifying the ClickOnceSample.exe.config.deploy file will not result in current users getting the new configurations.  We do not want to go back to Visual Studio and generate a new version as this might introduce unexpected code changes.  A new version of the application can be created by copying the folder (in this case ClickOnceSample_1_0_0_2) and pasting it into the application Files directory.  Rename the directory ‘ClickOnceSample_1_0_0_3’.  In the new folder open the configuration file in notepad and make the configuration changes. Run MageUI and open the manifest file in the newly copied directory (ClickOnceSample_1_0_0_3).   Edit the manifest version to reflect the newly copied files (in this case 1.0.0.3).  Then save the file.  Open the .application file in the root folder.  Again update the version to 1.0.0.3.  Since the file has not changed the Deployment Options/Start Location URL should still be correct.  The application Reference needs to be updated to point to the new versions .manifest file.  Save the file. Next time a user runs the application the new version of the configuration file will be down loaded.  It is worth noting that there are 2 different types of configuration parameter; application and user.  With Click Once deployment the difference is significant.  When an application is downloaded the configuration file is also brought down to the client machine.  The developer may have written code to update the user parameters in the application.  As a result each time a new version of the application is down loaded the user parameters are at risk of being overwritten.  With Click Once deployment the system knows if the user parameters are still the default values.  If they are they will be overwritten with the new default values in the configuration file.  If they have been updated by the user, they will not be overwritten. Settings configuration view in Visual Studio Production Deployment When deploying the code to production it is prudent to disable the development and test deployment sites.  This will allow errors such as incorrect URL to be quickly identified in the initial testing after deployment.  If the sites are active there is no way to know if the application was downloaded from the production deployment and not redirected to test or dev.   Troubleshooting Clicking the install button on the install.htm page fails. Error: URLDownloadToCacheFile failed with HRESULT '-2146697210' Error: An error occurred trying to download <file>   This is due to the setup.exe file pointing to the wrong location. ‘The setup.exe file that is created has the install URL hardcoded in it.  It is this screen that allows you to specify the URL to use.  At some point a setup.exe file must be generated for production.  Enter the production URL and deploy the solution to the dev folder.  This file can then be saved for latter use in deployment to production.  During development this URL should be pointing to development site to avoid accidently installing the production application.’

    Read the article

  • KVM machine does not start ssh, network is started, used to work

    - by lleto
    have been searching an pulling my hear out for the last 6 hours. I have a virtual machine that has been running fine for the last six months. I was happy ssh'ing into it and it was running a database and some small apps. Tonight ssh stopped working, so I decided to reboot the machine. I now have the following situation: virsh list --all states machine as running I can ping the machine and get a reply When I ssh to the machine I see "ssh: connect to host [myserver] port 22: Connection refused" nmap does not show port 22 as open I have tried to: - reboot the machine once more (no luck) - mount the filesystem and check /etc/ssh/sshd.conf (has not changed since working situation) - install virsh console, however this does not seem to work When I mount the fs directly using losetup the strange thing is that file dates seem to be frozen in /var/log/ around the time of the crash. If I look in /var/run/ I can see an sshd.pid, but the time is 6 hours ago (and numerous reboots). My virsh xml looks like this: <domain type='kvm' id='21'> <name>myserver</name> <uuid>09678c8d-a99b-1d18-a7af-88d027cc8f93</uuid> <memory>1048576</memory> <currentMemory>1048576</currentMemory> <vcpu>1</vcpu> <os> <type arch='x86_64' machine='pc-1.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> </features> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>destroy</on_crash> <devices> <emulator>/usr/bin/kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/dev/disk01/myserver'/> <target dev='hda' bus='ide'/> <alias name='ide0-0-0'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <controller type='ide' index='0'> <alias name='ide0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:e3:13:86'/> <source bridge='br0'/> <target dev='vnet0'/> <model type='virtio'/> <alias name='net0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <serial type='pty'> <source path='/dev/pts/1'/> <target port='0'/> <alias name='serial0'/> </serial> <console type='pty' tty='/dev/pts/1'> <source path='/dev/pts/1'/> <target type='serial' port='0'/> <alias name='serial0'/> </console> <input type='mouse' bus='ps2'/> <graphics type='vnc' port='5900' autoport='yes' listen='127.0.0.1'> <listen type='address' address='127.0.0.1'/> </graphics> <video> <model type='cirrus' vram='9216' heads='1'/> <alias name='video0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </video> <memballoon model='virtio'> <alias name='balloon0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </memballoon> </devices> <seclabel type='dynamic' model='apparmor' relabel='yes'> <label>libvirt-09678c8d-a99b-1d18-a7af-88d027cc8f93</label> <imagelabel>libvirt-09678c8d-a99b-1d18-a7af-88d027cc8f93</imagelabel> </seclabel> </domain> I'm sort of lost as to where I can look to get the machine up and running again. On the same instance of kvm I have another server running which is working fine. Both are Ubuntu 12.04. All help is welcome....

    Read the article

  • CIFS(Samba) + ACL = not working

    - by tst
    I have two servers with Debian 5.0. server1: samba 2:3.2.5-4lenny9 smbfs 2:3.2.5-4lenny9 smb.conf: [test] comment = test path = /var/www/_test/ browseable = no only guest = yes writable = yes printable = no create mask = 0644 directory mask = 0755 server1:~# mount | grep sda3 /dev/sda3 on /var/www type ext3 (rw,acl,user_xattr) # getfacl /var/www/_test/ # file: var/www/_test/ # owner: www-data # group: www-data user::rwx group::rwx other::r-x default:user::rwx default:user:www-data:rw- default:user:testuser:rw- default:group::rwx default:mask::rwx default:other::r-x server2: samba-common 2:3.2.5-4lenny9 smbfs 2:3.2.5-4lenny9 server2:~# mount.cifs //server1/test /media/smb/test -o rw,user_xattr,acl server2:~# mount | grep test //server1/test on /media/smb/test type cifs (rw,mand) server2:~# getfacl /media/smb/test/ # file: media/smb/test/ # owner: www-data # group: www-data user::rwx group::rwx other::r-x default:user::rwx default:user:www-data:rw- default:user:testuser:rw- default:group::rwx default:mask::rwx default:other::r-x And there is the problem: server2:~# su - testuser (reverse-i-search)`touch': touch 123 testuser@server2:~$ touch /media/smb/ testuser@server2:~$ touch /media/smb/test/123 touch: cannot touch `/media/smb/test/123': Permission denied Whats wrong?!

    Read the article

  • How do I install Apache Tomcat 7?

    - by Anupesh
    Troubleshooting with apache Tomcat 7 steps should be followed .... after downloading apache-Tomcat 7 // open terminal go to that downloading file folder in which tar.gz file is still. Untar the tar file tar -xzvf filename.tar.gz move a extracted directory of apache-Tomcat7 in current path sudo mv Directory_Name(Extracted eg.apache-Tomcat 7.0.32) /usr/local/Tomcat7 to set environment variable for Tomcat7 sudo nano /usr/local/Tomcat7/bin/setenv.sh then Nano editor will open .. JAVA_HOME =/usr/lib/jvm/java-6-sun export CATALINA_OPTS="$CATALINA_OPTS -Xms128m -Xmx1024m -XX:MaxPermSize=256m after hit ctrl+X to save file to set the role and username and password. sudo nano /usr/local/Tomcat7/conf/./tomcat-users.xml <role rolename="manager-gui" /> <role rolename="manager-script" /> <role rolename="manager-jmx" /> <role rolename="manager-status" /> <user username="admin" password="admin" roles="manager-gui,manager-script,manager-jmx,manager-status"/> Ctrl+X to save file If Port no confliction comes in a way then open file to change the port no. sudo nano /usr/local/Tomcat7/conf/./server.xml then change the connector port as you want....

    Read the article

  • Create a Shortcut To Group Policy Editor in Windows 7

    - by Mysticgeek
    If you’re a system administrator and find yourself making changes in Group Policy Editor, you might want to make a shortcut to it. Here we look at creating a shortcut, pinning it to the Taskbar, and adding it to Control Panel. Note: Local Group Policy Editor is not available in Home versions of Windows 7. Typing gpedit.msc into the search box in the Start menu to access Group Policy Editor can get old fast. To create a shortcut, right-click on the desktop and select New \ Shortcut. Next type or copy the following path into the location field and click Next. c:\windows\system32\gpedit.msc Then give your shortcut a name…something like Group Policy, or whatever you want it to be and click Finish. Now you have your Group Policy shortcut… If you want it on the Taskbar just drag it there to pin it. And that’s all there is to it!   If you want to change the icon, you can use one of the following guides… Customize Icons in Windows 7 Change a File Type Icon in Windows 7 Add Group Policy to Control Panel If you’re using non Home versions of XP, Vista, or Windows 7, check out The Geek’s article on how to Add Group Policy Editor to Control Panel. Similar Articles Productive Geek Tips Add Group Policy Editor to Control PanelQuick Tip: Disable Search History Display in Windows 7Remove Shutdown and Restart Buttons In Windows 7How To Disable Control Panel in Windows 7Allow Users To Run Only Specified Programs in Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Acronis Online Backup DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows Fun with 47 charts and graphs Tomorrow is Mother’s Day Check the Average Speed of YouTube Videos You’ve Watched OutlookStatView Scans and Displays General Usage Statistics How to Add Exceptions to the Windows Firewall Office 2010 reviewed in depth by Ed Bott

    Read the article

  • What changes can be made to a Microsoft Account using net user on Windows 8?

    - by nhinkle
    In Windows 8, you can log on with a local account or with a Microsoft Account. Both types show up in the Users control panel, but there are different options that you can change for each type. An administrator can change basically any aspect of a local user - name, password, access level, etc. For a Microsoft Account, you can only change the access level (admin/standard) or remove the account. From the command line though, there don't appear to be any restrictions on what you can do a Microsoft Account. Using the net user tool or the Local Users and Groups MMC snap-in, it looks like an administrator would be able to change the password, display name, profile path, etc. of Microsoft Accounts (as well as local accounts of course). Will these commands actually work when applied to a Microsoft Account? Will using them in some way break the link to the Microsoft Account, or will nothing happen at all? I'm hesitant to test since I don't want to mess up my account permanently.

    Read the article

  • Iomega Home Media Network Hard Drive: Accesing the data in the disk?

    - by JJarava
    Hi all! I have an Iomega Home Media Network Hard Drive, 1TB, and lately I can't access the data on the drive. The shares (both built-in and created by me) are there, the security works, but when trying to access the data I get a "The network path was not found" message which is worrying, to say the least. I'd like to know if there is a way to get the data off the disks somehow, as some of the data in the drive (ie, pictures and videos of my 1.5 yrs old son) is hard if not impossible to find otherwise. Thanks a lot Javier

    Read the article

  • Apache not running from rc.d on FreeBSD

    - by Oksana Molotova
    I'm using FreeBSD 8.3 and Apache 2.2. I didn't install Apache from ports, instead compiled it from source because I wanted to move the binary and configuration to a different path (I'm centering all of the major production daemons and their configurations in a single place). In any case, I based the /usr/local/etc/rc.d/apache22 file on one from a different server where it was installed from ports, I only modified the binary and config paths within. I can manually execute it with /usr/local/etc/rc.d/apache22 start, however even with apache22_enable="YES" in /etc/rc.conf it fails to start. All permissions and ownership are identical to the other server where it works. What am I missing and is there a way to debug this kind of thing?

    Read the article

  • Identifying the version of ATI Catalyst drivers

    - by snark
    I have bought a new video card based on the ATI Radeon HD 5670 chipset. I couldn't make it work with the latest ATI Catalyst drivers found on their website, only the drivers found on the CD delivered with the card worked. How can I know the version of Catalyst that is installed on my PC (running Windows 7 64-bits)? The ATI Catalyst Control Center returns the following information: Driver Packaging Version 8.673-091110a-092263C Provider ATI Technologies Inc. 2D Driver Version 8.01.01.973 2D Driver File Path /REGISTRY/MACHINE/SYSTEM/ControlSet001/Control/CLASS/{4D36E968-E325-11CE-BFC1-08002BE10318}/0000 Direct3D Version 8.14.10.0708 OpenGL Version 6.14.10.9120 Catalyst™ Control Center Version 2009.1110.2225.40230 I do not recognize anything pointing to a "marketing version". The website says the current version of Catalyst is 10.2.

    Read the article

  • Want to execute an arm compiled executable on adb shell of android

    - by user37977
    I stuck in a problem. I want a chmreader executable file to be used in android application. Now whenever I tried to execute it from adb shell, it gives error "permission denied" Now, whenever I use "su" it just executes the file, but doesn't do anything. And whenever I give the argument as the path of the file to be read, "# su /sdcard/extract_chmLib /sdcard/docs/HArdcore.chm" it shows "su: exec failed for /sdcard/docs/HArdcore.chm Error:Permission denied" where "/sdcard/extract_chmLib" is the executable file and "/sdcard/docs/HArdcore.chm" is the chm file to be read. Can you please help me???

    Read the article

  • Email Deliverability on Yahoo is very poor. Any suggestions please?

    - by xarejay28x
    All other ISPs (Google, AOL, Hotmail) are fantastic, hitting 98-100% in the inbox. Yahoo is very random, and lately our deliverability has dropped drastically. All IPs are senders certified by Return Path and supposedly that automatically whitelists our IPs and allows us to send as many emails as we want (from what my boss says). Do I bother with applying to Yahoo's bulk sender form? I run every email campaign through: SpamAssassin (Excellent Scores) Test Accounts (for test deliverability) Old school HTML format I'm running out of ideas and I'm starting to be in the hot seat and I am very fearful for my job position. If you can offer any wise words i will be very grateful. Thank you in advance.

    Read the article

  • How can I tell what user account is being used by a service to access a network share on a Windows 2008 server?

    - by Mike B
    I've got a third-party app/service running on a Windows 2003 SP2 server that is trying to fetch something from a network share on Windows 2008 box. Both boxes are members of an AD domain. For some reason, the app is complaining about having insufficient permissions to read/write to the store. The app itself doesn't have any special options for acting on the authority of another user account. It just asks for a UNC path. The service is running with a "log on as" setting of Local System account. I'd like to confirm what account it's using when trying to communicate with the network share. Conversely, I'd also like more details on if/why it's being rejected by the Windows 2008 network share. Are there server-side logs on 2008 that could tell me exactly why a connection attempt to a share was rejected?

    Read the article

  • install headers-more-nginx-module to existing nginx

    - by Hunt
    i have installed nginx but now i want to install headers-more-nginx-module into existing installation of nginx , so can someone tell me how to do it ? i have found following commands but it is with the new installation of nginx and then headers-more-nginx-module wget 'http://nginx.org/download/nginx-1.2.4.tar.gz' tar -xzvf nginx-1.2.4.tar.gz cd nginx-1.2.4/ # Here we assume you would install you nginx under /opt/nginx/. ./configure --prefix=/opt/nginx \ --add-module=/path/to/headers-more-nginx-module make make install currently i guess my nginx is under where the nginx.conf is placed etc/nginx

    Read the article

  • Delay of mail delivery - Hosted exchange provider

    - by alex
    Hi, I recently signed up to a new hosted email provider. When I send mail (from OWA, OR Outlook) there is a delay of up to 3 minutes from when i send the message, to when it's received (in my gmail account for example) I've listed the headers below. Is there anything I can advise my new email host to do? My previous email host delivers within 5 seconds!! New email provider: Delivered-To: ****.*****@******.co.uk.test-google-a.com Received: by 10.223.120.148 with SMTP id d20cs333125far; Mon, 30 Nov 2009 08:49:43 -0800 (PST) Received: by 10.213.106.202 with SMTP id y10mr4864870ebo.35.1259599782838; Mon, 30 Nov 2009 08:49:42 -0800 (PST) Return-Path: Received: from relay005.apm-internet.net (relay005.apm-internet.net [85.119.248.8]) by mx.google.com with SMTP id 26si13016480ewy.43.2009.11.30.08.49.42; Mon, 30 Nov 2009 08:49:42 -0800 (PST) Received-SPF: neutral (google.com: 85.119.248.8 is neither permitted nor denied by best guess record for domain of ****@*******.com) client-ip=85.119.248.8; Authentication-Results: mx.google.com; spf=neutral (google.com: 85.119.248.8 is neither permitted nor denied by best guess record for domain of ****@*******.com) smtp.mail=****@*******.com Received: (qmail 63915 invoked from network); 30 Nov 2009 16:49:41 -0000 Received: from unknown (HELO mx-out-manc2.simplymailsolutions.com) (88.151.129.22) by relay005.apm-internet.net with SMTP; 30 Nov 2009 16:49:42 -0000 X-APM-IP: 88.151.129.22 X-APM-Score: 4 Received-SPF: none (relay005.apm-internet.net: domain at alexjamesbrown.com does not designate permitted sender hosts) Received: from [10.1.20.1] (helo=win-s-manc1.shared.ifeltd.com) by mx-out-manc2.simplymailsolutions.com with esmtp (Exim 4.63) (envelope-from ) id 1NF9QZ-0005By-Hw for ****.*****@******.co.uk; Mon, 30 Nov 2009 16:48:46 +0000 Received: from sha-exch8.shared.ifeltd.com ([10.1.20.8]) by win-s-manc1.shared.ifeltd.com with Microsoft SMTPSVC(6.0.3790.3959); Mon, 30 Nov 2009 16:48:34 +0000 Received: from sha-exch9.shared.ifeltd.com ([10.1.20.9]) by sha-exch8.shared.ifeltd.com with Microsoft SMTPSVC(6.0.3790.3959); Mon, 30 Nov 2009 16:48:34 +0000 Received: from SHA-EXCH13.shared.ifeltd.com (10.1.20.13) by sha-exch9.shared.ifeltd.com (10.1.20.9) with Microsoft SMTP Server (TLS) id 8.1.393.1; Mon, 30 Nov 2009 16:48:25 +0000 Received: from SHA-EXCH12.shared.ifeltd.com ([fe80::ecba:36d0:eec5:c928]) by SHA-EXCH13.shared.ifeltd.com ([fe80::212b:916c:70c7:a4e5%11]) with mapi; Mon, 30 Nov 2009 16:48:05 +0000 From: Alex Brown To: "****.*****@*****.co.uk" Date: Mon, 30 Nov 2009 16:48:04 +0000 Subject: testing Thread-Topic: testing Thread-Index: AQHKcdzZg4oiDsOYIEio/7k6bCk8BQ== Message-ID: Accept-Language: en-US, en-GB Content-Language: en-GB X-MS-Has-Attach: X-MS-TNEF-Correlator: acceptlanguage: en-US, en-GB Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: quoted-printable MIME-Version: 1.0 X-OriginalArrivalTime: 30 Nov 2009 16:48:34.0235 (UTC) FILETIME=[F48178B0:01CA71DC] Here are the headers using my previous exchange host: Delivered-To: ****.*****@******.co.uk.test-google-a.com Received: by 10.223.120.148 with SMTP id d20cs333076far; Mon, 30 Nov 2009 08:48:35 -0800 (PST) Received: by 10.213.2.70 with SMTP id 6mr4797985ebi.25.1259599715739; Mon, 30 Nov 2009 08:48:35 -0800 (PST) Return-Path: Received: from relay005.apm-internet.net (relay005.apm-internet.net [85.119.248.8]) by mx.google.com with SMTP id 26si13030993ewy.23.2009.11.30.08.48.35; Mon, 30 Nov 2009 08:48:35 -0800 (PST) Received-SPF: neutral (google.com: 85.119.248.8 is neither permitted nor denied by best guess record for domain of ****@*********.com) client-ip=85.119.248.8; Authentication-Results: mx.google.com; spf=neutral (google.com: 85.119.248.8 is neither permitted nor denied by best guess record for domain of ****@*********.com) smtp.mail=****@*********.com Received: (qmail 60920 invoked from network); 30 Nov 2009 16:48:34 -0000 Received: from unknown (HELO MTAb.MsExchange2007.com) (89.31.236.50) by relay005.apm-internet.net with SMTP; 30 Nov 2009 16:48:35 -0000 X-APM-IP: 89.31.236.50 X-APM-Score: 1 Received-SPF: none (relay005.apm-internet.net: domain at alexjamesbrown.com does not designate permitted sender hosts) Received: from EXHUB02.SL.local (no.ptr.hostlogic.biz [89.31.236.28]) by MTAb.MsExchange2007.com (Spam Firewall) with ESMTP id B677A34FE0F for ; Mon, 30 Nov 2009 16:48:33 +0000 (GMT) Received: from EXHUB02.SL.local (no.ptr.hostlogic.biz [89.31.236.28]) by MTAb.MsExchange2007.com with ESMTP id 8X5B8V4tExVzoNyU for ; Mon, 30 Nov 2009 16:48:34 +0000 (GMT) Received: from EXCCR03STORE.SL.local ([10.0.0.2]) by EXHUB02.SL.local ([192.168.92.64]) with mapi; Mon, 30 Nov 2009 16:48:31 +0000 From: Alex James Brown To: "****.*****@******.co.uk" Date: Mon, 30 Nov 2009 16:48:30 +0000 Subject: testing from o Thread-Topic: testing from o Thread-Index: AQHKcdzyY1iBFWiol0ykG6xPQUZiTg== Message-ID: Accept-Language: en-US, en-GB Content-Language: en-GB X-MS-Has-Attach: X-MS-TNEF-Correlator: acceptlanguage: en-US, en-GB Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: quoted-printable MIME-Version: 1.0

    Read the article

  • BizTalk: mapping with Xslt

    - by Leonid Ganeline
    BizTalk Map Editor (Mapper) is a good editor, especially in the last 2010 version of the BizTalk. But still sometimes it cannot do the tasks easily. It is time for the Xslt code, It is time to remember that the maps are executed by the Xslt engine.  Right-click the Mapper Grid (a field between the source and target schemas) and choose Properties /Custom XSLT Path.  Input here a name of the file with Xslt code. Only this code will be executed, forget the picture in the Mapper, all those links and functoids.  Let’s see the real-life example. There are two source Addresses. One is on the top level and the second is inside the Member_Address record with MaxOccurs=* . The target address is placed inside the Locator record with MaxOccurs=*. The requirement is to map all source address to the one target address structure. The source Xml document looks like: The result Xml should be like this: Try to do this mapping with the Mapper and you will spent good amount of time and the result map would be tricky. If we use the Xslt code, the mapping will be simple and unambiguous, like this: Simple, elegant.

    Read the article

  • Role of Microsoft certifications ADO.Net, ASP.Net, WPF, WCF and Career?

    - by Steve Johnson
    I am a Microsoft fan and .Net enthusiast. I want to align my career in the lines of current and future .Net technologies. I have an MCTS in ASP.Net 3.5. The question is about the continuation of certifications and my career growth and maybe a different job! I want to keep pace with future Microsoft .Net technologies. My current job however doesn't allow so.So i bid to do .Net based certifications to stay abreast with latest .Net technologies. My questions: What certifications should i follow next? I have MCTS .Net 3.5 WPF(Exam 70-502) and MCTS .Net 3.5 WCF(Exam 70-504) in my mind so that i can go for Silverlight development and seek jobs related to Silverlight development. What other steps i need to take in order to develop professional expertise in technologies such as WPF, WCF and Silverlight when my current employer is reluctant to shift to latest .Net technologies? I am sure that there are a lot of people of around here who are working with .Net technologies and they have industrial experience. I being a new comer and starter in my career need to take right decision and so i am seeking help from this community in guiding me to the right path. Expert replies are much appreciated and thanks in advance. Best Regards Steve.

    Read the article

  • Executing a Batch file from remote Ax client on an AOS server

    - by Anisha
    Is it possible to execute a batch file on an AOS server from a remote AX client? Answer is yes, provided you have necessary permission for this execution on the server. Please create a batch file on your AOS server. Some thing as below for creating a directory on the server.    Insert a command something like this in a .BAT file (batch file) and place any were on the server.   Mkdir “c:\test”      Copy the following code into your server static method of your class and call this piece of code from a button click on Ax form. Please execute this button click from a remote AX client and see the result . This should execute the batch file on the server and should create a directory called ‘test’ on the root directoryof the server.     server static void AOS_batch_file_create() { boolean b; System.Diagnostics.Process process; System.Diagnostics.ProcessStartInfo processStartInfo; ; b = Global::isRunningOnServer(); infolog.add(0, int2str(b)); new InteropPermission(InteropKind::ClrInterop).assert(); process = new System.Diagnostics.Process(); processStartInfo = new System.Diagnostics.ProcessStartInfo(); processStartInfo.set_FileName("C:\\create_dir.bat"); // batch file path on the AOS server process.set_StartInfo(processStartInfo); process.Start(); //process.Refresh(); //process.Close(); //process.WaitForExit(); info("Finished"); }

    Read the article

  • KVM CLI install for CentOS 6.3 defaults to Minimal Install

    - by i.h4d35
    So I now I've installed KVM (and its associated tools and packages- libvirt, VMM etc.). On the GUI (i.e using the VMM), installation works as its supposed to. However, when I try to create a VM using the command line interface, the OS (I am working with CentOS 6.3) defaults to a Minimal Install instead of giving me options to choose from at the time of installation. I am trying to install using the following command: virt-install \ --connect qemu:///system \ --virt-type kvm --name testVM2 \ --ram 512 --disk path=/var/lib/libvirt/images/testVM2.img,size=8 --vnc \ --cdrom /media/db18de8e-0853-49fb-80de-5c794d58a46f/CentOS-6.3- x86_64-bin-DVD1.iso \ --network network=default Specifying the OS-type or the OS-variant parameters doesn't make a difference. Is there something that I am missing out on or some other parameter that I must specify? Thanks in advance.

    Read the article

  • Publish Static Content to WebLogic

    - by James Taylor
    Most people know WebLogic has a built in web server. Typically this is not an issue as you deploy java applications and WebLogic publishes to the web. But what if you just want to display a simple static HTML page. In WebLogic you can develop a simple web application to display static HTML content. In this example I used WLS 10.3.3. I want to display 2 files, an HTML file, and an xsd for reference. Create a directory of your choice, this is what I will call the document root. mkdir /u01/oracle/doc_root Copy the static files to this directory  In the document root directory created in step 1 create the directory WEB-INF mkdir WEB-INF In the WEB-INF directory create a file called web.xml with the following content <?xml version="1.0" encoding="UTF-8"?> <!DOCTYPE web-app PUBLIC "-//Sun Microsystems, Inc.//DTD Web Application 2.3//EN" "http://java.sun.com/j2ee/dtds/web-app_2_3.dtd"> <web-app> </web-app> Login to the WebLogic console to deploy application Click on Deployments Click on Lock & Edit Click Install and set the path to the directory created in step 1 Leave default "Install this deployment as an application" and click Next Select a Managed Server to deploy to and click Next Accept the defaults and click Finish  Deployment completes successfully, now click the Activate Changes You should now see the application started in the deployments You can now access your static content via the following URL http://localhost:7001/doc_root/helloworld.html

    Read the article

  • Jailkit - allowing use of Java/Python

    - by James hooker
    I'm looking to allow Jailed users to use JAVA (JRE) to execute their own Java files, similarly with Python to execute py scripts. I've tried adding the JAVA binary (/usr/bin/java) to a jail using the following jk_cp /path/to/jail /usr/bin/java This seems to copy some of the libraries across, aswell as the Java binary itself, however the jailed user is still unable to execute Java. It complains first of all of a missing lib called libsli.so. I copied that across and it then complains about libjava.so which I proceeded to copy across to, to no avail. Does anyone have experience with enabling the execution of Java within a jailed environment? This is under Ubuntu 10.04 64-bit, with Jailkit 2.11.

    Read the article

  • I can't run uwsgi as normal user

    - by atomAltera
    I want to run uwsgi server as www user, but if I write: uwsgi --socket $SOCKET --chmod-socket 666 --pidfile $PIDFILE --daemonize $LOGFILE --chdir $CHDIR --pp $PYTHONPATH --module main --post-buffering 8192 --workers 1 --threads 10 --uid www --gid www A socket creation error occurs: Log: 1 *** Starting uWSGI 1.4.1 (64bit) on [Mon Dec 10 22:15:23 2012] *** 2 compiled with version: 4.4.5 on 17 November 2012 23:31:14 3 os: Linux-2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 4 nodename: autoblog 5 machine: x86_64 6 clock source: unix 7 pcre jit disabled 8 detected number of CPU cores: 2 9 current working directory: / 10 writing pidfile to /tmp/uwsgi_mysite.pid 11 detected binary path: /usr/local/bin/uwsgi 12 setgid() to 1002 13 set additional group 1004 (files) 14 setuid() to 1002 15 *** WARNING: you are running uWSGI without its master process manager *** 16 your memory page size is 4096 bytes 17 detected max file descriptor number: 1024 18 lock engine: pthread robust mutexes 19 unlink(): Operation not permitted [core/socket.c line 109] 20 bind(): Address already in use [core/socket.c line 141]

    Read the article

  • Cannot set MemOpMode or ProcVirtualization with syscfg.exe

    - by EGr
    When attempting to set MemOpMode or ProcVirtualization with syscfg.exe, I get the following error: C:\Users\EGr>syscfg --MemOpMode=AdvEccMode System Services or CSIOR disabled In the past, I have been told that this can be resolved by forcefully reinstalling the Dell Lifecycle controller firmware, and then trying again; however, I cannot find my notes on how to do that. Has anyone ever run into this issue, and does anyone know how I can fix it? If it is possible to forcefully reinstall the firmware, how would I do that? I've tried running the installer, but it fails after running for ~2 min. I believe there is a way to fix this as well, by adding/modifying a registry value at HKLM\System\Control\CurrentControlSet\Services\IPMIDRV (that might not be the correct path, but I know it is IPMIDRV). Is this a common issue? What is the actual cause of it?

    Read the article

  • Organizations &amp; Architecture UNISA Studies &ndash; Chap 7

    - by MarkPearl
    Learning Outcomes Name different device categories Discuss the functions and structure of I/.O modules Describe the principles of Programmed I/O Describe the principles of Interrupt-driven I/O Describe the principles of DMA Discuss the evolution characteristic of I/O channels Describe different types of I/O interface Explain the principles of point-to-point and multipoint configurations Discuss the way in which a FireWire serial bus functions Discuss the principles of InfiniBand architecture External Devices An external device attaches to the computer by a link to an I/O module. The link is used to exchange control, status, and data between the I/O module and the external device. External devices can be classified into 3 categories… Human readable – e.g. video display Machine readable – e.g. magnetic disk Communications – e.g. wifi card I/O Modules An I/O module has two major functions… Interface to the processor and memory via the system bus or central switch Interface to one or more peripheral devices by tailored data links Module Functions The major functions or requirements for an I/O module fall into the following categories… Control and timing Processor communication Device communication Data buffering Error detection I/O function includes a control and timing requirement, to coordinate the flow of traffic between internal resources and external devices. Processor communication involves the following… Command decoding Data Status reporting Address recognition The I/O device must be able to perform device communication. This communication involves commands, status information, and data. An essential task of an I/O module is data buffering due to the relative slow speeds of most external devices. An I/O module is often responsible for error detection and for subsequently reporting errors to the processor. I/O Module Structure An I/O module functions to allow the processor to view a wide range of devices in a simple minded way. The I/O module may hide the details of timing, formats, and the electro mechanics of an external device so that the processor can function in terms of simple reads and write commands. An I/O channel/processor is an I/O module that takes on most of the detailed processing burden, presenting a high-level interface to the processor. There are 3 techniques are possible for I/O operations Programmed I/O Interrupt[t I/O DMA Access Programmed I/O When a processor is executing a program and encounters an instruction relating to I/O it executes that instruction by issuing a command to the appropriate I/O module. With programmed I/O, the I/O module will perform the requested action and then set the appropriate bits in the I/O status register. The I/O module takes no further actions to alert the processor. I/O Commands To execute an I/O related instruction, the processor issues an address, specifying the particular I/O module and external device, and an I/O command. There are four types of I/O commands that an I/O module may receive when it is addressed by a processor… Control – used to activate a peripheral and tell it what to do Test – Used to test various status conditions associated with an I/O module and its peripherals Read – Causes the I/O module to obtain an item of data from the peripheral and place it in an internal buffer Write – Causes the I/O module to take an item of data form the data bus and subsequently transmit that data item to the peripheral The main disadvantage of this technique is it is a time consuming process that keeps the processor busy needlessly I/O Instructions With programmed I/O there is a close correspondence between the I/O related instructions that the processor fetches from memory and the I/O commands that the processor issues to an I/O module to execute the instructions. Typically there will be many I/O devices connected through I/O modules to the system – each device is given a unique identifier or address – when the processor issues an I/O command, the command contains the address of the address of the desired device, thus each I/O module must interpret the address lines to determine if the command is for itself. When the processor, main memory and I/O share a common bus, two modes of addressing are possible… Memory mapped I/O Isolated I/O (for a detailed explanation read page 245 of book) The advantage of memory mapped I/O over isolated I/O is that it has a large repertoire of instructions that can be used, allowing more efficient programming. The disadvantage of memory mapped I/O over isolated I/O is that valuable memory address space is sued up. Interrupts driven I/O Interrupt driven I/O works as follows… The processor issues an I/O command to a module and then goes on to do some other useful work The I/O module will then interrupts the processor to request service when is is ready to exchange data with the processor The processor then executes the data transfer and then resumes its former processing Interrupt Processing The occurrence of an interrupt triggers a number of events, both in the processor hardware and in software. When an I/O device completes an I/O operations the following sequence of hardware events occurs… The device issues an interrupt signal to the processor The processor finishes execution of the current instruction before responding to the interrupt The processor tests for an interrupt – determines that there is one – and sends an acknowledgement signal to the device that issues the interrupt. The acknowledgement allows the device to remove its interrupt signal The processor now needs to prepare to transfer control to the interrupt routine. To begin, it needs to save information needed to resume the current program at the point of interrupt. The minimum information required is the status of the processor and the location of the next instruction to be executed. The processor now loads the program counter with the entry location of the interrupt-handling program that will respond to this interrupt. It also saves the values of the process registers because the Interrupt operation may modify these The interrupt handler processes the interrupt – this includes examination of status information relating to the I/O operation or other event that caused an interrupt When interrupt processing is complete, the saved register values are retrieved from the stack and restored to the registers Finally, the PSW and program counter values from the stack are restored. Design Issues Two design issues arise in implementing interrupt I/O Because there will be multiple I/O modules, how does the processor determine which device issued the interrupt? If multiple interrupts have occurred, how does the processor decide which one to process? Addressing device recognition, 4 general categories of techniques are in common use… Multiple interrupt lines Software poll Daisy chain Bus arbitration For a detailed explanation of these approaches read page 250 of the textbook. Interrupt driven I/O while more efficient than simple programmed I/O still requires the active intervention of the processor to transfer data between memory and an I/O module, and any data transfer must traverse a path through the processor. Thus is suffers from two inherent drawbacks… The I/O transfer rate is limited by the speed with which the processor can test and service a device The processor is tied up in managing an I/O transfer; a number of instructions must be executed for each I/O transfer Direct Memory Access When large volumes of data are to be moved, an efficient technique is direct memory access (DMA) DMA Function DMA involves an additional module on the system bus. The DMA module is capable of mimicking the processor and taking over control of the system from the processor. It needs to do this to transfer data to and from memory over the system bus. DMA must the bus only when the processor does not need it, or it must force the processor to suspend operation temporarily (most common – referred to as cycle stealing). When the processor wishes to read or write a block of data, it issues a command to the DMA module by sending to the DMA module the following information… Whether a read or write is requested using the read or write control line between the processor and the DMA module The address of the I/O device involved, communicated on the data lines The starting location in memory to read from or write to, communicated on the data lines and stored by the DMA module in its address register The number of words to be read or written, communicated via the data lines and stored in the data count register The processor then continues with other work, it delegates the I/O operation to the DMA module which transfers the entire block of data, one word at a time, directly to or from memory without going through the processor. When the transfer is complete, the DMA module sends an interrupt signal to the processor, this the processor is involved only at the beginning and end of the transfer. I/O Channels and Processors Characteristics of I/O Channels As one proceeds along the evolutionary path, more and more of the I/O function is performed without CPU involvement. The I/O channel represents an extension of the DMA concept. An I/O channel ahs the ability to execute I/O instructions, which gives it complete control over I/O operations. In a computer system with such devices, the CPU does not execute I/O instructions – such instructions are stored in main memory to be executed by a special purpose processor in the I/O channel itself. Two types of I/O channels are common A selector channel controls multiple high-speed devices. A multiplexor channel can handle I/O with multiple characters as fast as possible to multiple devices. The external interface: FireWire and InfiniBand Types of Interfaces One major characteristic of the interface is whether it is serial or parallel parallel interface – there are multiple lines connecting the I/O module and the peripheral, and multiple bits are transferred simultaneously serial interface – there is only one line used to transmit data, and bits must be transmitted one at a time With new generation serial interfaces, parallel interfaces are becoming less common. In either case, the I/O module must engage in a dialogue with the peripheral. In general terms the dialog may look as follows… The I/O module sends a control signal requesting permission to send data The peripheral acknowledges the request The I/O module transfers data The peripheral acknowledges receipt of data For a detailed explanation of FireWire and InfiniBand technology read page 264 – 270 of the textbook

    Read the article

  • Keyboard locking up in Visual Studio 2010, Part 2

    - by Jim Wang
    Last week I posted about looking into the keyboard locking up issue in Visual Studio.  So far it looks like not a lot of people have replied to provide concrete repro steps, which confirms my suspicion that this is somewhat of a random issue. So at this point, I have a couple of choices.  I can either wait for somebody in the community to provide a repro of the problem that I can reliably run into, or I can do the work myself. I’m going to do both, so while I’m waiting for more possible bug reports, I’m going to write a tool that models the behavior of a typical Visual Studio user and use that to hopefully isolate the problem. I’ve chosen to go with this path since given the information in the bug reports, it seems people hit the issue with many different configurations in many different scenarios.  This means that me sitting down without any solid repro steps is likely not going to be a good use of time.  Instead, I’m going to go with a model-based testing approach where I will define a series of actions that a user in VS can do, and then proceed to run my model.  I’ll let you guys know how this works out for isolating bugs :) I’m using an internal tool for the model engine and AutoIt for the UI automation (I want something lightweight for a one-off).  One of the challenges will be getting feedback: AutoIt is great at driving, but not so great at understanding what success and failure means.

    Read the article

< Previous Page | 325 326 327 328 329 330 331 332 333 334 335 336  | Next Page >