Search Results

Search found 9286 results on 372 pages for 'transfer speed'.

Page 337/372 | < Previous Page | 333 334 335 336 337 338 339 340 341 342 343 344  | Next Page >

  • usb_modeswitch not switching

    - by deniz
    After I upgraded from kernel 2.6.18 to 3.5.3 modeswitch started not to work for me. Although lsusb shows my usb modem, usb_modeswitch does not switch it. My system information is like below. I ran lsusb, dmesg, usb-devices and usb_modeswitch their output is like below. usb_modeswitch instead of switching my modem it says "No devices in default mode found. Nothing to do. Bye.". Can you offer a solution? Kernel: Linux 3.5.3 usb_modeswitch: 1.2.3-1 usb_modeswitch-data: 20120120-1 usbutils: 006-1 libusb: 1.0.8-0.1 root@localhost$ lsusb Bus 002 Device 029: ID 12d1:1446 Huawei Technologies Co., Ltd. root@localhost$ dmesg [70112.477080] usb 2-1.4: new high-speed USB device number 30 using ehci_hcd [70112.567757] scsi49 : usb-storage 2-1.4:1.0 [70112.567842] scsi50 : usb-storage 2-1.4:1.1 [70113.571433] scsi 49:0:0:0: CD-ROM HUAWEI Mass Storage 2.31 PQ: 0 ANSI: 2 [70113.572304] scsi 50:0:0:0: Direct-Access HUAWEI TF CARD Storage PQ: 0 ANSI: 2 [70113.574169] sr0: scsi-1 drive [70113.574223] sr 49:0:0:0: Attached scsi CD-ROM sr0 [70113.574250] sr 49:0:0:0: Attached scsi generic sg1 type 5 [70113.574350] sd 50:0:0:0: Attached scsi generic sg2 type 0 [70113.577173] sd 50:0:0:0: [sdb] Attached SCSI removable disk root@localhost$ usb-devices T: Bus=02 Lev=02 Prnt=02 Port=03 Cnt=01 Dev#= 30 Spd=480 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=12d1 ProdID=1446 Rev=00.00 S: Manufacturer=Huawei Technologies S: Product=HUAWEI Mobile C: #Ifs= 2 Cfg#= 1 Atr=c0 MxPwr=500mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage I: If#= 1 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage root@localhost$ cat /etc/usb_modeswitch.d/12d1\:1446 # Huawei, newer modems TargetVendor= 0x12d1 TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" MessageContent="55534243123456780000000000000011062000000100000000000000000000" root@localhost$ usb_modeswitch -c /etc/usb_modeswitch.d/12d1:1446 -v 12d1 -p 1446 -W * usb_modeswitch: handle USB devices with multiple modes * Version 1.2.3 (C) Josua Dietze 2012 * Based on libusb0 (0.1.12 and above) ! PLEASE REPORT NEW CONFIGURATIONS ! DefaultVendor= 0x12d1 DefaultProduct= 0x1446 TargetVendor= 0x12d1 TargetProduct= not set TargetClass= not set TargetProductList="1001,1406,140b,140c,1412,141b,1433,1436,14ac,1506" DetachStorageOnly=0 HuaweiMode=0 SierraMode=0 SonyMode=0 QisdaMode=0 GCTMode=0 KobilMode=0 SequansMode=0 MobileActionMode=0 CiscoMode=0 MessageEndpoint= not set MessageContent="55534243123456780000000000000011062000000100000000000000000000" NeedResponse=0 ResponseEndpoint= not set InquireDevice enabled (default) Success check disabled System integration mode disabled usb_set_debug: Setting debugging level to 15 (on) usb_os_find_busses: Skipping non bus directory devices usb_os_find_busses: Skipping non bus directory drivers usb_os_find_busses: Skipping non bus directory uevent usb_os_find_busses: Skipping non bus directory drivers_probe usb_os_find_busses: Skipping non bus directory drivers_autoprobe Looking for target devices ... No devices in target mode or class found Looking for default devices ... No devices in default mode found. Nothing to do. Bye. Thanks in advance.

    Read the article

  • Brand new Mac Pro tower fan suddenly runs full-tilt

    - by Caffeine Coma
    My Quad-Core Mac Pro tower is two days old. Initially, I was impressed with how quiet it was compared to my older Macbook Pro. Then on day two, for some reason it started running very loudly. It's not just a "little" loud- my wife walked into the room and asked what the noise was. At first I thought this was just because I was hitting the CPU a bit (importing my iPhone library into iLife '09, and running Eclipse). But now that that's done, Activity Monitor shows a virtually idle CPU; there's nothing running that ought to be causing this, as far as I can tell. I tried powering it off & letting it cool down for a few minutes to no avail; about 10 seconds after powering up, the box gets loud again. I took a look at it with the side cover off, and it seems to be the fan near the top middle, between the power supply and the disk drive. It can't be a dust issue, as the machine is only 2 days old (and I peeked inside anyway just to be sure- clean). I did do a software update over the past 24 hours or so, but I can't say that it occurred immediately after that. I also did a migration of my old apps and data from my MBPro, for what it's worth. Why is it suddenly so loud? How can I monitor the fan speed and various system temperatures? Here's a link to my temps and fan speeds. UPDATE 1: Took it to the Apple Store. They took it in the back (where it's presumably quieter) and ran a fan diagnostic; no problems were found. The guy also told me that it was "a little loud", but normal. I don't buy it. It was virtually silent the first 24 hours I was using it. They would not replace/service it in the store (grrr... that's why I went there, as directed by Apple Care) but said I could get a replacement from the online store, as it was just purchased. I think I will try that. UPDATE 2: Apple is letting me send it back for a replacement. Glad to see so many responses to this question mentioning that the MacPros are usually silent; it's not all just in my head. :-)

    Read the article

  • Revolutionary brand powder packing machine price from affecting marketplace boom and put on uniform in addition to a lengthy service life

    - by user74606
    In mining in stone crushing, our machinery company's encounter becomes much more apparent. As a consequence of production capacity in between 600~800t/h of mining stone crusher, stone is mine Mobile Cone Crushing Plant Price 25~40 times, effectively solved the initially mining stone crusher operation because of low yield prices, no upkeep problems. Full chunk of mining stone crusher. Maximum particle size for crushing 1000x1200mm, an effective answer for the original side is mine stone provide, storing significant chunks of stone can not use complications in mines. Completed goods granularity is modest, only 2~15mm, an effective option for the original mine stone size, generally blocking chute production was an issue even the grinding machine. Two types of material mixed great uniformity, desulfurization of mining stone by adding weight considerably. Present quantity added is often reached 60%, effectively minimizing the cost of raw supplies. Electrical energy consumption has fallen. Dropped 1~2KWh/t tons of mining stone electrical energy consumption, annual electricity savings of one hundred,000 yuan. Efficient labor intensity of workers and also the atmosphere. Due to mine stone powder packing machine price a high degree of automation, with out human make contact with supplies, workers working circumstances enhanced significantly. Positive aspects, and along with mine for stone crushing, CS series cone Crusher has the following efficiency traits. CS series cone Crusher Chamber is divided into 3 unique designs, the user is usually chosen in accordance with the scenario on site crushing efficiency is high, uniform item size, grain shape, rolling mortar wall friction and put on uniform in addition to a extended service life of crushing cavity-. CS series cone Crusher utilizes a one of a kind dust-proof seal, sealing dependable, properly extend the service life of the lubricant replacement cycle and parts. CS series Sprial Sand washer price manufacture of important components to choose unique materials. Each and every stroke left rolling mortar wall of broken cone distances, by permitting a lot more products into the crushing cavity, as well as the formation of big discharge volume, speed of supplies by way of the crushing Chamber. This machine makes use of the principle of crushing cavity, also as unique laminated crushing, particle fragmentation, so that the completed product drastically improved the proportions of a cube, needle-shaped stones to lower particle levels extra evenly.

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • Is my Cisco switch port bad?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced last week, however the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link (switchport configuration pastebin). We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Set up lnux box for hosting a-z

    - by microchasm
    I am in the process of reinstalling the OS on a machine that will be used to host a couple of apps for our business. The apps will be local only; access from external clients will be via vpn only. The prior setup used a hosting control panel (Plesk) for most of the admin, and I was looking at using another similar piece of software for the reinstall - but I figured I should finally learn how it all works. I can do most of the things the software would do for me, but am unclear on the symbiosis of it all. This is all an attempt to further distance myself from the land of Configuration Programmer/Programmer, if at all possible. I can't find a full walkthrough anywhere for what I'm looking for, so I thought I'd put up this question, and if people can help me on the way I will edit this with the answers, and document my progress/pitfalls. Hopefully someday this will help someone down the line. The details: CentOS 5.5 x86_64 httpd: Apache/2.2.3 mysql: 5.0.77 (to be upgraded) php: 5.1 (to be upgraded) The requirements: SECURITY!! Secure file transfer Secure client access (SSL Certs and CA) Secure data storage Virtualhosts/multiple subdomains Local email would be nice, but not critical The Steps: Download latest CentOS DVD-iso (torrent worked great for me). Install CentOS: While going through the install, I checked the Server Components option thinking I was going to be using another Plesk-like admin. In hindsight, considering I've decided to try to go my own way, this probably wasn't the best idea. Basic config: Setup users, networking/ip address etc. Yum update/upgrade. Upgrade PHP: To upgrade PHP to the latest version, I had to look to another repo outside CentOS. IUS looks great and I'm happy I found it! cd /tmp #wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/epel-release-1-1.ius.el5.noarch.rpm #rpm -Uvh epel-release-1-1.ius.el5.noarch.rpm #wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/ius-release-1-4.ius.el5.noarch.rpm #rpm -Uvh ius-release-1-4.ius.el5.noarch.rpm yum list | grep -w \.ius\. [will list all packages available in the IUS repo] rpm -qa | grep php [will list installed packages needed to be removed. the installed packages need to be removed before you can install the IUS packages otherwise there will be conflicts] #yum shell >remove php-gd php-cli php-odbc php-mbstring php-pdo php php-xml php-common php-ldap php-mysql php-imap Setting up Remove Process >install php53 php53-mcrypt php53-mysql php53-cli php53-common php53-ldap php53-imap php53-devel >transaction solve >transaction run Leaving Shell #php -v PHP 5.3.2 (cli) (built: Apr 6 2010 18:13:45) This process removes the old version of PHP and installs the latest. To upgrade mysql: Pretty much the same process as above with PHP #/etc/init.d/mysqld stop [OK] rpm -qa | grep mysql [installed mysql packages] #yum shell >remove mysql mysql-server Setting up Remove Process >install mysql51 mysql51-server mysql51-devel >transaction solve >transaction run Leaving Shell #service mysqld start [OK] #mysql -v Server version: 5.1.42-ius Distributed by The IUS Community Project The above upgrade instructions courtesy of IUS wiki: http://wiki.iuscommunity.org/Doc/ClientUsageGuide Create a chroot jail to hold sftp user via rssh. This will force SCP/SFTP and will circumvent traditional FTP server setup. #cd /tmp #wget http://dag.wieers.com/rpm/packages/rssh/rssh-2.3.2-1.2.el5.rf.x86_64.rpm #rpm -ivh rssh-2.3.2-1.2.el5.rf.x86_64.rpm #useradd -m -d /home/dev -s /usr/bin/rssh dev #passwd dev Edit /etc/rssh.conf to grant access to SFTP to rssh users. #vi /etc/rssh.conf Uncomment line allowscp This allows me to connect to the machine via SFTP protocol in Transmit (my FTP program of choice; I'm sure it's similar with other FTP apps). Above instructions for SFTP appropriated (with appreciation!) from http://www.cyberciti.biz/tips/linux-unix-restrict-shell-access-with-rssh.html And this is where I'm at. I will keep editing this as I make progress. Any tips on how to Configure virtual interfaces/ip based virtual hosts for SSL, setting up a CA, or anything else would be appreciated.

    Read the article

  • Why is my new Phenom II 965 BE not significantly faster than my old Athlon 64 X2 4600+?

    - by Software Monkey
    I recently rebuilt my 5 year old computer. I upgraded all core components, in particular from an Athlon 64 X2 4600+ at 2.4 GHz with DDR2 800 to a Phenom II 965 BE (quad core) at 3.6 GHz with DDR3 1333 (actually 1600, but testing consistently detected memory errors at 1600). The motherboard is also much newer and better. The HDD's (x3), DVD writer and card reader are the same. The BIOS memory config is auto-everything except the base timing which I overrode to 1T instead of 2T. The BIOS CPU multiplier is slightly over-clocked to 3.6 GHz from the stock 3.4 GHz. I noticed compiling Java is slower than I expected. As it happens I have some (single-threaded) Java pattern-matching code which is CPU and memory bound and for which I have performance numbers recorded on a number of hardware platforms, including my old system. So I did a test run on the new equipment and was stunned to find that the numbers are only slightly better than my old system, about 25%. The data set it is operating on is a 148,975 character array, which should easily fit in caches, but in any event the new CPU has larger caches all around. The system was, of course, otherwise idle for the test and the test run is a timed 10 seconds to eliminate scheduling anomalies. A long while ago, when I upgraded only memory from DD2 667 to DDR2 800 there was no change in performance of this test, which subjectively supports that the test cycle does not need to (significantly) access main memory, but yes it is creating and garbage collecting a large number of objects in the process of this test (low millions of matches are found for the pattern set). I am about 99.999% certain the code hasn't changed since I last ran it on 2009-03-17 - but I can't easily retest the old hardware, because it is currently in pieces on my work-bench waiting to be built into a new computer for my kids. Note that Windows (XP) reports a CPU speed of 795 MHz unless I have some thing running. With stuff running it seems to jump all over the place each time I use ALT-Pause to display the system properties, everywhere from 795 MHz to 3.4 Ghz. So why might my shiny new hardware under-performing so badly? EDIT: The old memory was Mushkin DDR2 800 with timings set for auto which should have been 5-5-5-12. The new memory is Corsair DDR3 1600, running at 1333 with timings also auto which are 9-9-9-21. In both cases they are a paired set of dual channel DIMMs. I was waiting to ensure my system was stable before tweaking with memory timings.

    Read the article

  • Yahoo is sending our server's transactional email to the Spam folder, even though we have set up SPF and DKIM

    - by Derrick Miller
    Yahoo Mail is sending our server's transactional emails to the Spam folder, even though we have taken quite a few anti-spam steps. By contrast, Gmail allows the messages through to the inbox just fine. Here are the things which are in place: SPF is set up for the domain holsteinplaza.com. Yahoo reports spf=pass in the message headers. DKIM is set up for the domain holsteinplaza.com. Yahoo reports dkim=pass in the message headers. We have a proper reverse DNS entry for the sending mail server. Name - IP matches IP - Name. Neither Domainkeys nor SenderID are set up. From what I can tell, DKIM is the way of the future, and there is not much to be gained from adding Domainkeys or SenderID. Following are the headers. Any ideas what more I should do to get Yahoo to stop flagging the emails as spam? From Holstein Plaza Auctions Sat Jun 25 18:30:08 2011 X-Apparently-To: [email protected] via 98.138.90.132; Sat, 25 Jun 2011 18:30:11 -0700 Return-Path: <[email protected]> X-YahooFilteredBulk: 70.32.113.42 Received-SPF: pass (domain of holsteinplaza.com designates 70.32.113.42 as permitted sender) X-YMailISG: i_vaA_QWLDuLOmXhDjUv3aBKJl5Un6EiP6Yk2m4yn3jeEuYK MkhpqIt9zDUbHARCwXrhl9pqjTANurGVca7gytSs.mryWVQcbWBx.DaItWRb VcyrIzwMzXKCSeu06H2a.cJ7HG5vJLJaKmHUUI_1ttXKn_Aegiu5yHvFX83R Lpth0witO9zfaKvOMaJV3LAxpIpFOydwvq1cqjZ8nURxQbxM3Cl.QW7MxxrC 09qLVn_D_xSdU94QdU22IsVmlaRHv.uU5dnIazu.KSkhKpYykDoZA2SH0SY4 JmTZj3LP8N926xXVDzYQ5K6QvKuJL5g0d9pYZx3KC59sgIu5oHlJ3Q15RdKb f3OJw0PR6oIyJ2yStVr8vfbDgOfj3qig03.Tw6g6MMNpv1G7Cuol4oJeUaYP xELxX6dHgBgCSuWMcbsrxbK4BIXcS2qhpMqYQ4Isk.XXyA8uvmFXyvgc1ds5 8jo0rW.Wsw.55Z.KTPaQ0gHXj0T3OGppYMELSJv1iuhPyyAnZpmq01CU0Qd5 CcRgdyW3HaqhmpXqJCS0Clo16zXA4HmAjR0tgIQrHRLc3D9N02AOzvmDgCb1 vCh0p00QeKVq8UNkcShPRxZFKi9khtkLhPBlXEKkhJ76zyDmHUxTY.dQHVVD 8D2hx7BxbqI9DINI8x5oR5Q8hYkZqHYQsmGNkaU77O2BnsEv5WxMEmzrBJ4Z h8zGCidgYPiZycZfnfaBp0Xb4tya2WMTN45W02JFcO1qq_UMJ9xPeqZhPEj. j9YvBAC8324GGF.c8eWcNB2VB34QHgTcVUl3.c0XUCuncls9Cyg4L7AoIdCi HvAklSzDDu9nW6732VEipV9FJ_JkDupDNQU2hfiPG.3OeF8GwTnVYnEn0EiZ aO0NCnZhXuLDcN3K7ml3846yRdASvzPFs9s4aJkzR0FkhVvptiMBEOdRkKdG wHWmvWpK4GTZpW4yU7CnKpW2MiWWn1MP0h_CCZFKs5.3mfmfPjPVIABN_RuU Q8ex5hdKnKlQiqK56LzcPRnYmNtrwdsUX9CYn9d6cPpXR_Bi5jrNJMNzdFvq lGO0CBT4QPe2V45U8PtpMitttuDA1cCvmyBPFswxNlL0jyX0a_W.vl0YW5.d HhDItpHhDxKRUscM28IR.exetq4QCzyM X-Originating-IP: [70.32.113.42] Authentication-Results: mta1267.mail.ac4.yahoo.com from=holsteinplaza.com; domainkeys=neutral (no sig); from=holsteinplaza.com; dkim=pass (ok) Received: from 127.0.0.1 (EHLO predator.axis80.com) (70.32.113.42) by mta1267.mail.ac4.yahoo.com with SMTP; Sat, 25 Jun 2011 18:30:11 -0700 Received: (qmail 1440 invoked by uid 48); 25 Jun 2011 21:30:09 -0400 To: [email protected] Subject: this is a test X-PHPMAILER-DKIM: phpmailer.worxware.com DKIM-Signature: v=1; a=rsa-sha1; q=dns/txt; l=203; s=auction; t=1309051808; c=relaxed/simple; h=From:To:Subject; d=holsteinplaza.com; [email protected]; z=From:=20Holstein=20Plaza=20Auctions=20<[email protected]> |To:[email protected] |Subject:=20this=20is=20a=20test; bh=B3Tw5AQb1va627KEoazuFEBZ0fg=; b=oQ5uFq+oekPTGhszyIritjuuIAi3qPNyeitu+aWMhdx3oC6O2j5hJsDFpK0sS5fms7QdnBkBcEzT0iekEvn9EfAdCkGZ2KrtEC0yv7QKQcrjXxy07GJpj9nq0LYbgOuPdw8mGvKxlRZ+jFBX0DRJm0xXFLkr+MEaILw7adHTCCM= Date: Sat, 25 Jun 2011 21:30:08 -0400 From: Holstein Plaza Auctions <[email protected]> Reply-to: Holstein Plaza Auctions <[email protected]> Message-ID: <[email protected]> X-Priority: 3 X-Mailer: PHPMailer 5.1 (phpmailer.sourceforge.net) MIME-Version: 1.0 Content-Transfer-Encoding: 8bit Content-Type: text/plain; charset="iso-8859-1" Content-Length: 195

    Read the article

  • Vim configuration slow in Terminal & iTerm2 but not in MacVim

    - by Jey Balachandran
    Ideally, I want to use Vim from Terminal or iTerm2. However, it becomes unbearably slow so I had to resort to using MacVim. There is nothing wrong with MacVim, however my workflow would be much smoother if I used only Terminal/iTerm2. When its slow Loading files, in particular Rails files takes about 1 - 1.5s. Removing rails.vim decreases this time to 0.5 - 1s. In MacVim this is instantaneous. Scrolling through the rows and columns via h, j, k, l. It progressively gets slower the longer I hold down the keys. Eventually, it starts jumping rows. I have my Key Repeat set to Fast and Delay Until Repeat set to Short. After 10 - 15 minutes of usage, using plugins such as ctrlp or Command-T gets very laggy. I'd type a letter, wait 2 - 3s, then type the next. My Setup 11" MacBook Air running Mac OS X Version 10.7.3 (1.6 Ghz Intel Core 2 Duo, 4 GB DDR3) My dotfiles. > vim --version VIM - Vi IMproved 7.3 (2010 Aug 15, compiled Nov 16 2011 16:44:23) MacOS X (unix) version Included patches: 1-333 Huge version without GUI. Features included (+) or not (-): +arabic +autocmd -balloon_eval -browse ++builtin_terms +byte_offset +cindent -clientserver +clipboard +cmdline_compl +cmdline_hist +cmdline_info +comments +conceal +cryptv -cscope +cursorbind +cursorshape +dialog_con +diff +digraphs -dnd -ebcdic +emacs_tags +eval +ex_extra +extra_search +farsi +file_in_path +find_in_path +float +folding -footer +fork() -gettext -hangul_input +iconv +insert_expand +jumplist +keymap +langmap +libcall +linebreak +lispindent +listcmds +localmap -lua +menu +mksession +modify_fname +mouse -mouseshape +mouse_dec -mouse_gpm -mouse_jsbterm +mouse_netterm -mouse_sysmouse +mouse_xterm +multi_byte +multi_lang -mzscheme +netbeans_intg +path_extra -perl +persistent_undo +postscript +printer +profile +python -python3 +quickfix +reltime +rightleft +ruby +scrollbind +signs +smartindent -sniff +startuptime +statusline -sun_workshop +syntax +tag_binary +tag_old_static -tag_any_white -tcl +terminfo +termresponse +textobjects +title -toolbar +user_commands +vertsplit +virtualedit +visual +visualextra +viminfo +vreplace +wildignore +wildmenu +windows +writebackup -X11 -xfontset -xim -xsmp -xterm_clipboard -xterm_save system vimrc file: "$VIM/vimrc" user vimrc file: "$HOME/.vimrc" user exrc file: "$HOME/.exrc" fall-back for $VIM: "/usr/local/Cellar/vim/7.3.333/share/vim" Compilation: /usr/bin/llvm-gcc -c -I. -Iproto -DHAVE_CONFIG_H -DMACOS_X_UNIX -no-cpp-precomp -O3 -march=core2 -msse4.1 -w -pipe -D_FORTIFY_SOURCE=1 Linking: /usr/bin/llvm-gcc -L. -L/usr/local/lib -o vim -lm -lncurses -liconv -framework Cocoa -framework Python -lruby I've tried running without any plugins or syntax highlighting. It opens files a lot faster but still not as fast as MacVim. But the other two problems still exist. Why is my vim configuration slow? How can I improve the speed of my vim configuration within Terminal or iTerm2?

    Read the article

  • Why many applications close after opening a document or doing a specific actions?

    - by Mohsen Farjami
    I have some encrypted pdf files that have no problem and in my last windows, I could open them easily with Adobe Reader 9.2 and other pdf readers. But now, I can only open non-encrypted pdf files and one encrypted file with Adobe Reader. every time I open almost any encrypted pdf, it closes itself. Also, when I try to search a folder for a keyword with Foxit Reader, once it closed. This is not related to Adobe Reader, because I have the same problem with Word 2007. When I open a document, sometimes it closes instantly and sometimes it closes after a few seconds and sometimes it is stable. My windows is Fresh. I have installed it a few days ago. I have ESET Smart Security 5.2 and I have updated it today. OS: XP Pro SP3, RAM: 3 GB, CPU: 2 GHZ, HDD: 320 GB My installed applications: Adobe AIR Adobe Flash Player 11 ActiveX Adobe Flash Player 11 Plugin Adobe Photoshop CS4 Adobe Reader 9.2 Atheros Wireless LAN Client Adapter Babylon Bluetooth Stack for Windows by Toshiba CCleaner Conexant HD Audio Dell Touchpad ESET Smart Security Farsi (101) Custom Foxit Reader Framing Studio 3.27 Google Chrome Hard Disk Sentinel PRO HDAUDIO Soft Data Fax Modem with SmartCP Intel(R) Graphics Media Accelerator Driver IrfanView (remove only) Java(TM) 6 Update 18 K-Lite Mega Codec Pack 8.8.0 Microsoft .NET Framework 2.0 Service Pack 1 Microsoft .NET Framework 3.0 Service Pack 1 Microsoft .NET Framework 3.5 Microsoft Data Access Components KB870669 Microsoft Office 2007 Primary Interop Assemblies Microsoft Office Enterprise 2007 Microsoft User-Mode Driver Framework Feature Pack 1.0.0 (Pre-Release 5348) Mozilla Firefox 7.0.1 (x86 en-US) Notepad++ Office Tab FreeEdition 8.50 ParsQuran PerfectDisk 12 Professional Registry First Aid RICOH R5C83x/84x Flash Media Controller Driver Ver.3.54.06 Sahar Money Manager 2.5 Stickies 7.1d The KMPlayer (remove only) TurboLaunch 5.1.2 Unlocker 1.9.1 USB Safely Remove 4.2 Virastyar Visual Studio 2005 Tools for Office Second Edition Runtime Winamp Windows Internet Explorer 8 Windows Media Player 11.0.5358.4826 Windows XP Service Pack 3 WinRAR 4.11 (32-bit) WorkPause 1.2 Z Dictionary My startup applications: WorkPause USB Safely Remove TurboLaunch SunJavaUpdateSched Stickies rfagent Persistence ParsQuran Daily Verse ITSecMng IgfxTray HotKeysCmds Hard Disk Sentinel egui disable shift+delete CTFMON.EXE Bluetooth Manager Babylon Client Apoint AdobeCS4ServiceManager Adobe Reader Speed Launcher Adobe ARM What should I do to solve it? If you recommend installing Windows again, what guarantees that it won't happen again?

    Read the article

  • Core i7 c1e and speedstepping - BSOD on shutdown

    - by DeaconDesperado
    I'm having an interesting problem with my recent Core i7 Digital Audio workstation build that I am curious to see if others have encountered. First, here are the specs on the machine. ASUS P6TD Deluxe Intel X58 Socket LGA1366 MB Intel Core i7-950 3.06Ghz 8M LGA1366 CPU CORSAIR DOMINATOR 6GB (3 x 2GB) 240-Pin DDR3 SDRAM DDR3 1600 Western Digital Caviar Black WD5001AALS 500GB Plus a couple ASUS optical drives and a 750W Corsair PSU. Running Windows 7 x64. All this is connected to the nefarious Digi 002 firewire audio interface for use with Pro Tools. I following mostly the specs posted by many other I7 users in the digidesign community who pooled their collective knowledge in this thread. Now after completing my build, I fell victim to the "UD5 squeal" described at that forum thread. So taking the advice posted, I disabled c1e advanced halt state and Intel speed stepping (I would likely have done this anyway to maintain a stable clock, power consumption isn't really a relevant concern on this machine.) I enabled XMP to set the ram timings properly as well. What I am experiencing is a BSOD upon shutdown, but only immediately after windows fully exits and ends all processes. The error is a MACHINE_CHECK_EXCEPTION 0x000000. The funny thing is that it is extremely intermitent and only occurs if the shutdown immediately followed a period of relative idleness. It does not a generate a minidump, I suspect because windows monitoring has terminated by the time this error occurs. No damage is evident and one can simply turn off manually and the system will act as though a proper shutdown had occurred. If anything it is a annoyance, I just want to be certain it is not affecting my long term stability. I have read that the i7 950 does not like DRAM voltages past 1.65, but that they are acceptable if they are within .5 of the BLCK setting. I have tried disabling XMP and setting all timings to auto and the problem still manifests in an identical way. It is suspect that the cpu idleness preceding shutdown is the determining factor, as both c1e and speedstepping are both settings intended to modify handling of this state. Any suggestions or prior experiences would be greatly appreciated. EDIT: The behavior very closely resembles what's described in this thread: http://www.tomshardware.com/forum/12003-63-shut-problem-windows The benign nature of it of is identical. I can't seem to download the hotfix cited there however.

    Read the article

  • Simple mdadm RAID 1 not activating spare

    - by Nick Liu
    I had created two 2TB HDD partitions (/dev/sdb1 and /dev/sdc1) in a RAID 1 array called /dev/md0 using mdadm on Ubuntu 12.04 LTS Precise Pangolin. The command sudo mdadm --detail /dev/md0 used to indicate both drives as active sync. Then, for testing, I failed /dev/sdb1, removed it, then added it again with the command sudo mdadm /dev/md0 --add /dev/sdb1 watch cat /proc/mdstat showed a progress bar of the array rebuilding, but I wouldn't spend hours watching it, so I assumed that the software knew what it was doing. After the progress bar was no longer showing, cat /proc/mdstat displays: md0 : active raid1 sdb1[2](S) sdc1[1] 1953511288 blocks super 1.2 [2/1] [U_] And sudo mdadm --detail /dev/md0 shows: /dev/md0: Version : 1.2 Creation Time : Sun May 27 11:26:05 2012 Raid Level : raid1 Array Size : 1953511288 (1863.01 GiB 2000.40 GB) Used Dev Size : 1953511288 (1863.01 GiB 2000.40 GB) Raid Devices : 2 Total Devices : 2 Persistence : Superblock is persistent Update Time : Mon May 28 11:16:49 2012 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 Name : Deltique:0 (local to host Deltique) UUID : 49733c26:dd5f67b5:13741fb7:c568bd04 Events : 32365 Number Major Minor RaidDevice State 1 8 33 0 active sync /dev/sdc1 1 0 0 1 removed 2 8 17 - spare /dev/sdb1 I've been told that mdadm automatically replaces removed drives with spares, but /dev/sdb1 isn't being moved into the expected position, RaidDevice 1. UPDATE (30 May 2012): A badblocks destructive read-write test of the entire /dev/sdb yielded no errors as expected; both HDDs are new. As of the latest edit, I assembled the array with this command: sudo mdadm --assemble --force --no-degraded /dev/md0 /dev/sdb1 /dev/sdc1 The output was: mdadm: /dev/md0 has been started with 1 drive (out of 2) and 1 rebuilding. Rebuilding looks like it's progressing normally: md0 : active raid1 sdc1[1] sdb1[2] 1953511288 blocks super 1.2 [2/1] [U_] [>....................] recovery = 0.6% (13261504/1953511288) finish=2299.7min speed=14060K/sec unused devices: <none> I'm now waiting on this rebuild, but I'm expecting /dev/sdb1 to become a spare just like the five or six times that I've tried rebuilding before. UPDATE (31 May 2012): Yeah, it's still a spare. Ugh! UPDATE (01 June 2012): I'm trying Adrian Kelly's suggested command: sudo mdadm --assemble --update=resync /dev/md0 /dev/sdb1 /dev/sdc1 Waiting on the rebuild now... My questions are: Why isn't the spare drive becoming active sync? How can I make the spare drive become active?

    Read the article

  • Email sent from Centos end up in user spam folder

    - by oObe
    I am facing this issue, I use the default postfix MTA in centos but the mail end up in user spam folder, but this does not seem to be a problem in Debian using exim4, both host have hostname and domain name configured, and relay mail through external smtp host. Both configuration and recieving email header are attached. The different seems that Debian has this additional (envelope tag) and (from) tag other than some minor syntax differences. Any help to resolve is appreciated. The IP address and DNS is masked as follow: 1.2.3.4 = My IP address smtp.host.com = external smtp host for my company [email protected] = account at smtp host centos.abc.com = Local centos server debian.abc.com = Local debian server Thanks. Centos main.cf config with the following params configured myhostname = centos.abc.com mydomain = abc.com myorigin = centos.abc.com relayhost = smtp.host.com Centos - User receiving mail header Return-Path: <[email protected]> Received: from 1.2.3.4 [1.2.3.4] by smtp.host.com with SMTP; Thu, 27 Sep 2012 13:36:49 +0800 Received: by centos.abc.com (Postfix, from userid 0) id 1E0637B89; Fri, 28 Sep 2012 13:36:39 +0800 (SGT) Return-Path: <[email protected]> Received: from 1.2.3.4 [1.2.3.4] by smtp.host.com with SMTP; Thu, 27 Sep 2012 13:36:49 +0800 Received: by centos.abc.com (Postfix, from userid 0) id 1E0637B89; Fri, 28 Sep 2012 13:36:39 +0800 (SGT) Date: Fri, 28 Sep 2012 13:36:39 +0800 To: [email protected] Subject: Test mail from centos User-Agent: Heirloom mailx 12.4 7/29/08 MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Transfer-Encoding: 7bit Message-Id: <[email protected]> From: [email protected] (root) X-SmarterMail-TotalSpamWeight: 0 X-Antivirus: avast! (VPS 120926-1, 27/09/2012), Inbound message X-Antivirus-Status: Clean http://i.imgur.com/7WAYX.jpg Debain exim4 config .... # This is a Debian specific file dc_eximconfig_configtype='smarthost' dc_other_hostnames='debian.abc.com' dc_local_interfaces='127.0.0.1 ; ::1' dc_readhost='debian.abc.com' dc_relay_domains='smtp.host.com' dc_minimaldns='false' dc_relay_nets='127.0.0.1' dc_smarthost='smtp.host.com' CFILEMODE='644' dc_use_split_config='false' dc_hide_mailname='true' dc_mailname_in_oh='true' dc_localdelivery='mail_spool' debian - User receiving mail header Return-Path: <[email protected]> Received: from 1.2.3.4 [1.2.3.4] by smtp.host.com with SMTP; Thu, 27 Sep 2012 15:02:53 +0800 Received: from root by debian.abc.com with local (Exim 4.72) (envelope-from <[email protected]>) id 1TH86d-00010v-G9 for [email protected]; Thu, 27 Sep 2012 15:01:55 +0800 Return-Path: <[email protected]> Received: from 1.2.3.4 [1.2.3.4] by smtp.host.com with SMTP; Thu, 27 Sep 2012 15:02:53 +0800 Received: from root by debian.abc.com with local (Exim 4.72) (envelope-from <[email protected]>) id 1TH86d-00010v-G9 for [email protected]; Thu, 27 Sep 2012 15:01:55 +0800 Date: Thu, 27 Sep 2012 15:01:55 +0800 Message-Id: <[email protected]> To: [email protected] Subject: Test from debian From: root <[email protected]> X-SmarterMail-TotalSpamWeight: 0 X-Antivirus: avast! (VPS 120926-1, 27/09/2012), Inbound message X-Antivirus-Status: Clean http://imgur.com/nMsMA.jpg

    Read the article

  • How to connect FreeBSD Jail to network

    - by jgtumusiime
    So recently I successfully installed and configured a freebsd jail and I would like to install software within my jail but I cannot connect to the network. I'm trying to setup an apache+php+mysql installation within the jail and have the webserver accessible by users. Here is my rc.conf for the jail. ... jail_enable="YES" # Set to NO to disable starting of any jails jail_list="mambo2" # Space separated list of names of jails jail_mambo2_rootdir="/usr/jails/j01" # jail's root directory jail_mambo2_hostname="mambo2.ug" # jail's hostname jail_mambo2_ip="192.168.100.174" # jail's IP address jail_mambo2_devfs_enable="YES" # mount devfs in the jail jail_mambo2_devfs_ruleset="mambo2_ruleset" # devfs ruleset to apply to jail here is my jail ifconfig output mambo2# ifconfig rl0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=8<VLAN_MTU> ether 00:c1:28:00:48:db media: Ethernet autoselect (100baseTX <full-duplex>) status: active plip0: flags=108810<POINTOPOINT,SIMPLEX,MULTICAST,NEEDSGIANT> metric 0 mtu 1500 lo0: flags=8049<UP,LOOPBACK,RUNNING,MULTICAST> metric 0 mtu 16384 mambo2# It does not show the IP address I configured within /etc/rc.conf. But, when I list the running jails, it shows the right IP address. Here is a list of jails running [root@mambo /usr/home/jtumusiime]# jls JID IP Address Hostname Path 5 192.168.100.174 mambo2.ug /usr/jails/j01 I also created a /etc/resolv.conf for nameservers. This was not in existence so I'm not quite sure if it is necessary? mambo2# cat /etc/resolv.conf nameserver 192.168.100.251 nameserver 8.8.8.8 mambo2# my host has 4 ip addresses, 3 public and one private: 192.168.100.173 I tried creating a jail using ezjail and this does not work out. [root@mambo /usr/src]# ezjail-admin update -p -i Error: Cannot find your copy of the FreeBSD source tree in . Consider using 'ezjail-admin install' to create the base jail from an ftp server. [root@mambo /usr/src]# I have an updated copy of freebsd 7.1 source tree from SVN in /usr/src/ [root@mambo /usr/src]# svn info Path: . URL: http://svn.freebsd.org/base/release/7.1.0 Repository Root: http://svn.freebsd.org/base Repository UUID: ccf9f872-aa2e-dd11-9fc8-001c23d0bc1f Revision: 243371 Node Kind: directory Schedule: normal Last Changed Author: kensmith Last Changed Rev: 186660 Last Changed Date: 2009-01-01 01:57:14 +0300 (Thu, 01 Jan 2009) [root@mambo /usr/src]# and I did #make buildworld while building the first jail i.e mambo2 Here is an excerpt of ouput of ezjail-admin install ... 221 Goodbye. Trying 193.162.146.4... Connected to ftp.freebsd.org. 220 ftp.beastie.tdk.net FTP server (Version 6.00LS) ready. 331 Guest login ok, send your email address as password. 230 Guest login ok, access restrictions apply. Remote system type is UNIX. Using binary mode to transfer files. 200 Type set to I. 550 pub/FreeBSD-Archive/old-releases/i386/7.1-RELEASE/base: No such file or directory. 221 Goodbye. Could not fetch base from ftp.freebsd.org. Maybe your release (7.1-RELEASE) is specified incorrectly or the host ftp.freebsd.org does not provide that release build. Use the -r option to specify an existing release or the -h option to specify an alternative ftp server. Querying your ftp-server... The ftp server you specified (ftp.freebsd.org) seems to provide the following builds: Trying 193.162.146.4... total 10 drwxrwxr-x 13 1006 1006 512 Feb 20 2011 8.2-RELEASE drwxrwxr-x 13 1006 1006 512 Apr 10 2012 8.3-RELEASE lrwxr-xr-x 1 1006 1006 16 Jan 7 2012 9.0-RELEASE -> i386/9.0-RELEASE drwxrwxr-x 7 1006 1006 1024 Feb 19 2012 ISO-IMAGES -rw-rw-r-- 1 1006 1006 637 Nov 23 2005 README.TXT drwxrwxr-x 5 1006 1006 512 Nov 2 02:59 i386 I do not want to upgrade my freebsd installation. I have googled around; but all in vail. Thank you

    Read the article

  • Why does writing a file to an NFS share send a COMMIT operation to the NFS server?

    - by Antonis Christofides
    I have a Debian squeeze (2.6.32-5-amd64) which is at the same time a NFS4 server and client (it mounts itself through NFS4). The local directory that leads directly to disk is /nfs4exports/mydir, whereas /nfs4mounts/mydir is the same thing mounted through NFS, using the machine's external IP address. Here is the line from fstab: 192.168.1.75:/mydir /nfs4mounts/mydir nfs4 soft 0 0 I have an application that writes many small files. If I write directly to /nfs4exports/mydir, it writes thousands of files per second; but if I write to /nfs4mounts/mydir, it writes 4 files per second or so. I can greatly increase speed if I add async to /etc/exports. (Writing a single large file to the NFS-mounted directory goes at more than 100 MB/s.) I examine the server statistics and I see that whenever a file is written, it is "committed" (this also happens with NFSv3): root@debianvboxtest:~# mount -t nfs4 192.168.1.75:/mydir /mnt root@debianvboxtest:~# nfsstat|grep -A 2 'nfs v4 operations' Server nfs v4 operations: op0-unused op1-unused op2-future access close commit 0 0% 0 0% 0 0% 10 4% 1 0% 1 0% root@debianvboxtest:~# echo 'hello' >/mnt/test1056 root@debianvboxtest:~# nfsstat|grep -A 2 'nfs v4 operations' Server nfs v4 operations: op0-unused op1-unused op2-future access close commit 0 0% 0 0% 0 0% 11 4% 2 0% 2 0% Now in the RFC, I read this: The COMMIT operation is similar in operation and semantics to the POSIX fsync(2) system call that synchronizes a file's state with the disk (file data and metadata is flushed to disk or stable storage). COMMIT performs the same operation for a client, flushing any unsynchronized data and metadata on the server to the server's disk or stable storage for the specified file. I don't understand why the client commits. I don't think that the "echo" shell built-in command runs fsync; if echo wrote to a local file and then the machine went down, the file might be lost. In contrast, the NFS client appears to be sending a COMMIT upon completion of the echo. Why? I am reluctant to use the async NFS server option, because it would apparently ignore COMMIT. I feel as if I had a local filesystem and I had to choose between syncing every file upon close and ignoring fsync altogether. What have I understood wrong?

    Read the article

  • How to diagnose and solve an erratic "HDCP Support Required"?

    - by Jom Orgstrom
    I am playing a digital tv broadcast on Windows Media Center for Windows 7. I built this system so it works with HDCP, and in fact I have been able to watch tv and bluray before with this same computer. However, I suddenly started getting an "HDCP Support Required" error from WMC. The entire message is as follows: HDCP Support Required High-bandwidth Digital Content Protection (HDCP) may not be supported by the current video card. Use an HDCP-compliant display, video card, and video driver. Or, connect using an analog connection such as component or VGA. Relevant specs are: CPU: Ivy Bridge Core i7-3770 Motherboard: Asus P8H77-I Memory: 16GB DDR3-1600 Graphics: Radeon HD 7850 (Driver by AMD, version 8.982.0.0 built on 2012/07/27) Display: Acer P243w connected by HDMI Sound: Roland Quad-Capture (It complains even when I use the bundled VIA HD Audio) TV Tuner: I-O Data GV-MC7/HZ3 OS: Windows 7 Professional SP1, Windows Update enabled. All patched and up to date. As you can see, there is nothing weird or old about my setup. I am also not doing anything strange, not doing any overclocking, weird system changes and so on. One thing that does happen from time to time, is that the display goes black for a few seconds (sometimes when watching media contents, sometimes when just using photoshop or Visual Studio). This happened with my previous setup as well, so I'd be inclined to think it is a display or cable issue (apart from the BD drive, these are the only things I kept from my previous setup to this one). But being a digital transfer, as far as I know, these things either work or not. Never erratically or with decreased quality. The thing is that sometimes I can watch the TV, sometimes not. This happens with recorded programs as well, so it's not a per-program thing. Sometimes rebooting helps, sometimes it doesn't. Sometimes unplugging and plugging back the HDMI connector helps, sometimes it doesn't. Sometimes doing so doesn't even turn the screen back on, so I have to reboot. Unfortunately, WMC's error message is quite unhelpful. I'd like to know exactly where the problem is, so I can solve it. I don't want to buy a brand new display just to then find out it was a registry setting that was misconfigured. I've tried looking at the system event viewer, but these errors don't show up at all in there. Other people who have this problem seem to have a setup that is not HDCP compliant, so I turn to you guys here. Anybody knows how to diagnose this problem? Edit: So I got the Cyberlink Blu-ray disc advisor. I ran it and told me everything was okay, except for the Video Connection Type, which showed as "Digital (without HDCP)". I then proceeded to unplug the power cable from the monitor, plugged it in again, ran the tool again, and now it's "Digital (with HDCP)". Needless to say, I can watch my TV and recorded programs on WMP again. I'm guessing that at some point, something may be slightly wrong with the HDCP setup, and Windows decides to reset the entire content protection path (which leads to the screen blanking out). Usually the reset succeeds, but sometimes it doesn't, so Windows defaults to turning HDCP off. There's no way to turn it back on, except by doing a hard reset of the display. I really want to know what the exact error was, so I can fix it. Is it the cable? is it the display? is it the video card? the driver? Also, is there any other way to try and turn HDCP on again without having to hard reset the display? Oh, questions, questions...

    Read the article

  • Radeon HD4850 serious issues when using DirectX 10

    - by ricsmania
    Hello, I have a problem with my video card. Whenever I run a DirectX 10 game, it works for a few seconds (10 or so) and then starts displaying nothing but big polygons. I have tested this with Crysis and Resident Evil 5, both have the same problems. The same games running under DirectX 9 work fine, except for some small black squares once in a while. I have the following specs: Asus P7P55D LE Intel Core i5 750 Sapphire Radeon HD4850 1GB 2x2GB Patriot Viper II Sector 5, DDR3 1600 MHz OCZ Stealth X Stream 500SXS 500W At first I thought it could be the video card overheating (it has stock cooling), but the game crashes even when it's running at 50 degrees C, and it's never been higher than 70. I also thought it could be the PSU, but as far as I know 500W is enough for this computer, especially because I haven't overclocked anything. My OS is Windows 7 X64 and I am using Catalyst 10.10, but I have also tried many older versions with no success. I don't think there is a problem with the card itself, or else it wouldn't run DirectX 9 games I believe. I have spent many hours searching for a solution but I couldn't, so any help is appreciated. Thank you. EDIT: I did some further investigation about the problem, and it seems taspeotis was right, it might be related to memory. I slightly underclocked the memory from 993 to 965 MHz and the problem went away completely. Both the black squares using DirectX 9 and the weird polygons using DirectX 10. I was using RE DirectX 10 Benchmark, as it consistently crashed around the same point, and now I can play the full benchmark with no artifacts at all. Unfortunately, the underclock has an obvious hit in performance. Although it's not critical, it's definitely noticeable. So, if the video memory test software showed no erros, but the card needs an underclock to work, what might be the problem? Temperature? Voltage? By the way, I couldn't find what the default voltage for this card is. And what is a good software to try and increase it? I tried Ati Tray Tools but it has a bug that increases the clock speed dramatically whenever I change something in the Overclock tab, so I'm afraid it might fry my card. Worst case scenario, if I don't find I solution I will try to slightly increase the GPU clock to compensate for the memory clock. Thank you again.

    Read the article

  • Server 2008, 2 NICs, 2 fixed IPs - big delays using internet

    - by user46055
    Hi geniuses I have an all in one Windows 2008 server, configured with AD/DHCP/DNS/RRAS - all set up with wizards and no specific tweaking. The server has 2 network adapters : one of which ("MyWAN") is plugged into our office's internet connection, the other ("MyLAN") is plugged into a local switch, which is also where all our desktops are connected. So this one server is doing everything. When first set up, MyLAN had a fixed IP of 192.168.2.1 and served the desktops with DHCP scope 192.168.2.50-99. It also told them to use 192.168.2.1 as DNS and gateway. MyWAN was setup to take its IP etc from DHCP, being handled by the building's router and ADSL modem etc. All desktops were setup to use DHCP. This all worked perfectly fine, until I recently changed MyWAN to have a static IP (I wanted to access it from home, and needed to give it a static IP to port map in the building's router). Things still work, but there is now a long delay when accessing the internet. The actual speed is as before when downloading, but there is a pause of 3-6 secs when connecting to new hosts (for example if I browse to slashdot from either a desktop or the server itself, it'll hang on connecting to slashdot.org, hang again on connecting to *.fsdn, *.google-analytics.com and all the other hosts referenced from the main page). If I ping slashdot.org from the server, I get the following : Pinging slashdot.org [216.34.181.45] with 32 bytes of data: Reply from 192.168.2.1: Destination host unreachable. Reply from 216.34.181.45: bytes=32 time=99ms TTL=239 Reply from 216.34.181.45: bytes=32 time=100ms TTL=239 Reply from 216.34.181.45: bytes=32 time=101ms TTL=239 Pinging anywhere external always seems to hit 192.168.2.1 first, which doesn't seem right. Trying tracert from the server gives the following : Tracing route to slashdot.org [216.34.181.45] over a maximum of 30 hops: 1 MYSERVER01.intranet [192.168.2.1] reports: Destination host unreachable Trying tracert from a desktop gives the following : Tracing route to slashdot.org [216.34.181.45] over a maximum of 30 hops: 1 <1 ms * <1 ms MYSERVER [192.168.2.1] 2 * * * Request timed out. 3 6 ms 6 ms 6 ms dsl-gw1.ge.mer.uk.webtapestry.net [217.151.111.17] 4 38 ms 239 ms 251 ms gw-router.ge.mer.uk.webtapestry.net [217.151.111.13] ...and then all is fine after that. I think that DNS is working fine because the domain names are getting translated to correct IPs immediately. DHCP seems to be okay? So perhaps it's something up with my RRAS setup - although I can't see any option during the setup wizard which I would have filled in differently. I've also tried changing the binding order of the two network connections, to prioritise MyWAN, but that doesn't seem to have done anything. Any idea what's up? Many thanks - Rob

    Read the article

  • Squid not caching files (Randomly)

    - by Heinrich
    I want to use an intercepting squid server to cache specific large zip files that users in my network download frequently. I have configured squid on a gateway machine and caching is working for "static" zip files that are served from an Apache web server outside our network. The files that I want to have cached by squid are zip files 100MB which are served from a heroku-hosted Rails application. I set an ETag header (SHA hash of the zip file on the server) and Cache-Control: public header. However, these files are not cached by squid. This, for example, is a request that is not cached: $ curl --no-keepalive -v -o test.zip --header "X-Access-Key: 20767ed397afdea90601fda4513ceb042fe6ab4e51578da63d3bc9b024ed538a" --header "X-Customer: 5" "http://MY_APP.herokuapp.com/api/device/v1/media/download?version=latest" * Adding handle: conn: 0x7ffd4a804400 * Adding handle: send: 0 * Adding handle: recv: 0 ... > GET /api/device/v1/media/download?version=latest HTTP/1.1 > User-Agent: curl/7.30.0 > Host: MY_APP.herokuapp.com > Accept: */* > X-Access-Key: 20767ed397afdea90601fda4513ceb042fe6ab4e51578da63d3bc9b024ed538a > X-Customer: 5 > 0 0 0 0 0 0 0 0 --:--:-- 0:00:09 --:--:-- 0< HTTP/1.1 200 OK * Server Cowboy is not blacklisted < Server: Cowboy < Date: Mon, 18 Aug 2014 14:13:27 GMT < Status: 200 OK < X-Frame-Options: SAMEORIGIN < X-Xss-Protection: 1; mode=block < X-Content-Type-Options: nosniff < ETag: "95e888938c0d539b8dd74139beace67f" < Content-Disposition: attachment; filename="e7cce850ae728b81fe3f315d21a560af.zip" < Content-Transfer-Encoding: binary < Content-Length: 125727431 < Content-Type: application/zip < Cache-Control: public < X-Request-Id: 7ce6edb0-013a-4003-a331-94d2b8fae8ad < X-Runtime: 1.244251 < X-Cache: MISS from AAA.fritz.box < Via: 1.1 vegur, 1.1 AAA.fritz.box (squid/3.3.11) < Connection: keep-alive In the logs squid is reporting a TCP_MISS. This is the relevant excerpt from my squid file: # Squid normally listens to port 3128 http_port 3128 http_port 3129 intercept # Uncomment and adjust the following to add a disk cache directory. maximum_object_size 1000 MB maximum_object_size_in_memory 1000 MB cache_dir ufs /usr/local/var/cache/squid 10000 16 256 cache_mem 2000 MB # Leave coredumps in the first cache dir coredump_dir /usr/local/var/cache/squid cache_store_log daemon:/usr/local/var/logs/cache_store.log #refresh_pattern -i (/cgi-bin/|\?) 0 0% 0 refresh_pattern -i .(zip) 525600 100% 525600 override-expire ignore-no-cache ignore-no-store refresh_pattern . 0 20% 4320 ## DNS Configuration dns_nameservers 8.8.8.8 8.8.4.4 After trying around for some time I realized that squid is sometimes deciding that my file is cacheable, sometimes not, depending on whether and when I enable/disable the dns_nameservers directive. What could be wrong here?

    Read the article

  • Email from my new vps is marked as spam

    - by Chriswede
    I got a new vps from x10vps (x10hosting) and set up the domain via cloudflare. This is what the email looks like: Delivered-To: [email protected] Received: by 10.64.19.240 with SMTP id i16csp357708iee; Tue, 9 Oct 2012 01:29:48 -0700 (PDT) Received: by 10.50.57.130 with SMTP id i2mr908846igq.56.1349771387599; Tue, 09 Oct 2012 01:29:47 -0700 (PDT) Return-Path: <[email protected]> Received: from power.SOURCEAPE.COM ([198.91.90.116]) by mx.google.com with ESMTPS id v8si25630942ica.46.2012.10.09.01.29.46 (version=TLSv1/SSLv3 cipher=OTHER); Tue, 09 Oct 2012 01:29:47 -0700 (PDT) Received-SPF: temperror (google.com: error in processing during lookup of [email protected]: DNS timeout) client-ip=198.91.90.116; Authentication-Results: mx.google.com; spf=temperror (google.com: error in processing during lookup of [email protected]: DNS timeout) [email protected] Received: from nk11p03mm-asmtp010.mac.com ([17.158.232.169]:54276) by power.SOURCEAPE.COM with esmtp (Exim 4.80) (envelope-from <[email protected]>) id 1TLVBD-0004Ig-1Y for [email protected]; Tue, 09 Oct 2012 12:28:43 +0400 I then tried to enable SPF and DKIM and got following massage In order to ensure that SPF or DKIM takes effect, you must confirm that this server is an authoritative nameserver for chvw.de. If you need help, contact your hosting provider. Status: Enabled Warning: cPanel is unable to verify that this server is an authoritative nameserver for chvw.de. [?] and the email header now looks like this: Delivered-To: [email protected] Received: by 10.50.183.227 with SMTP id ep3csp14506igc; Tue, 9 Oct 2012 01:55:23 -0700 (PDT) Received: by 10.50.40.133 with SMTP id x5mr992934igk.32.1349772923717; Tue, 09 Oct 2012 01:55:23 -0700 (PDT) Return-Path: <[email protected]> Received: from power.SOURCEAPE.COM ([198.91.90.116]) by mx.google.com with ESMTPS id ng8si25688859icb.42.2012.10.09.01.55.23 (version=TLSv1/SSLv3 cipher=OTHER); Tue, 09 Oct 2012 01:55:23 -0700 (PDT) Received-SPF: temperror (google.com: error in processing during lookup of [email protected]: DNS timeout) client-ip=198.91.90.116; Authentication-Results: mx.google.com; spf=temperror (google.com: error in processing during lookup of [email protected]: DNS timeout) [email protected]; dkim=neutral (bad format) [email protected] DKIM-Signature: v=1; a=rsa-sha256; q=dns/txt; c=relaxed/relaxed; d=chvw.de; s=default; h=Message-ID:Subject:To:From:Date:Content-Transfer-Encoding:Content-Type:MIME-Version; bh=iugsx3Lx0KnqjR7dj3wyQHnJ9pe/z3ntYEVk80k8rx4=; b=IrYsCtHdoPubXVOvLqxd7sLE/TyQTS5P3OrEg5SSUSKnQQcQ/fWWyBrmsrgkFSsw6jCmmRWMDR09vH5bQRpFPMA57B7pf8QRKhwXOWFBV+GnVUqICsfRjnNPvhx/lNp5; Received: from localhost ([127.0.0.1]:46539 helo=direct.chvw.de) by power.SOURCEAPE.COM with esmtpa (Exim 4.80) (envelope-from <[email protected]>) id 1TLVb0-0004dZ-Kd for [email protected]; Tue, 09 Oct 2012 12:55:22 +0400

    Read the article

  • OpenVPN multiple servers on the same subnet, high availability

    - by andre
    Hey everyone. Let me start by saying that my Linux experience isn't super awesome but I can usually find my way around things easily. Over at work we have an OpenVPN setup that's been due for some improvement for a while now. The main server (tap mode) runs in our office, behind a rather slow DSL connection. The main problem is that, since I'm usually out of the office, every time I want to access something on the virtual network I have to go through that server to get anywhere else. We have two servers up on 100 Mbit connections that we use for development and production purposes, about 3 more servers in the office (one of them behind a different T1 line for VOIP) and about two dozen clients who use the network on a daily basis from various locations. We've had situations where network routing (outside of our control) would not allow people to reach our main OpenVPN server whilst the other locations were connectable. Also any time someone outside the office wants to fetch something from any of the servers (say, a 500 MB code repository), a whopping 20 KB/s download speed is just unacceptable these days (did I mention slow DSL? ok). We had to implement traffic shaping on this server since maxing out this connection was fairly trivial. I had the thought of running two (or more) OpenVPN servers in the network. These would have to have the same subnet though, as our application relies on virtual network's IP addresses for some of its core functionality. The clients would also preferably retain the same IP addresses but that's not vital. For simplicity, lets call the current server office and the second server I'm setting up, cloud. Call the server on the T1 phone. This proved to be rather complex because as soon as I connect to cloud, I cannot see office. Any routes to a server that would go through office also do not work while I'm connected to cloud (no ping, nothing) and vice-versa. There's no rules for iptables that would be blocking the traffic either. Recently I came across this article on linuxjournal but the solution they provide seems to only cover the use of two servers and somewhat outdated (can't even find much documentation, their wiki is offline). They also state that adding more servers would be a complex task. Ideally I would like to keep the existing server office running the virtual network and also run the OpenVPN daemon on the cloud and phone servers (100 Mbit and very reliable connection, respectively) so that we're on safe ground in case of a hardware failure, DSL failure, etc. So, in essence, I'm looking for a highly available OpenVPN solution (fix, patch, hack, tweak, whatever you want to call it) that will accept connections on multiple hosts (2 or more) whilst keeping the same IP address subnet regardless of the server to which you connect to. Thanks for reading and sorry for the long post, I hope it gets the point across :P

    Read the article

  • Windows 7, HTTPS WebDav: Asks for password twice and fails. Any workarounds?

    - by AutoDMC
    Howdy. I have a Dav server running with PHP SabreDav (code.google.com/p/sabredav/wiki/Windows) on Cherokee at an HTTPS secured URL. It's set to use https, and uses Digest Authentication. I can log in with multiple browsers and a few third party clients (BitKinex and Java AnyClient can connect and browse as well, caveats below). However, when attempting to log in with Windows 7 (surprise, surprise), it asks for my password twice, then tells me that my folder is invalid. I have verified that the server is using Digest authentication. I've verified multiple times that third party software can connect. I even went out and bought a GoDaddy SSL certificate so my SSL wouldn't be self signed anymore. I've applied the registry hacks here: support.microsoft.com/kb/943280 (Note that the article says the "fix" already exists for Windows 7, I just need magical registry hax to get it to work) I've applied the registry hacks here: support.microsoft.com/kb/941050 I've applied the registry hacks here: support.microsoft.com/kb/841215 (Supposedly allows Basic Auth, which shouldn't apply, but why not?) All to no avail; Windows continues to ask for my password twice, then state that "The folder you entered does not appear to be valid. Please choose another." Try the command line? Sure: I've attempted to access with NET USE "https://dav.example.com/" password /USER:me (System error 59) I've attempted to access with NET USE "https://dav.example.com/" (System error 1790) I've attempted to access with NET USE "https://dav.example.com/subdir/" password /USER:me (System error 59) I've attempted to access with NET USE "https://dav.example.com/subdir/" (System error 1790) For good luck: ping dav.example.com ... works. And again, web browsers can access the share just fine, so can third party tools. Best I can tell at this point is "HAHA, NO WEBDAV FOR YOU ON WINDOWS 7" which would be fine except everyone who will be using this application... uses Windows 7. And most are not as persistent or pugnacious as I am. I feel like I've burned through every random suggestion I've found anywhere in the first 10 pages of Google on every search term I can think of. Any ideas? I need it to be Webdav, I need it to be over HTTPS, and I really do need a method to access it from Windows 7. EXTRA DETAIL: However, the "third party" programs I've tried have either been buggy, incomplete, or have silly ... "glitches." For example, BitKinex seems to fixate on any http error codes sent, so if there's a glitch reading a directory, BAM, that directory is always listed empty. Long directory listings also show up as blank, even though the transfer panel shows that directory listing is still taking place. In any case, BitKinex is useless for development purposes for the reasons above. And besides, I'm building this for people other than myself, people who will want to get this dav share working "the regular way."

    Read the article

  • Linksys WiFi usb dongle and linux woes

    - by MrStatic
    I have a Linksys WUSB54GC usb dongle and I have exhausted every thing I know about making this thing work in linux. I am using Fedora 13. Since it is not ready I can not view any networks. Any ideas would be great. tail of the system log Jun 2 20:14:35 localhost kernel: usb 1-7: new high speed USB device using ehci_hcd and address 8 Jun 2 20:14:35 localhost kernel: usb 1-7: New USB device found, idVendor=1737, idProduct=0077 Jun 2 20:14:35 localhost kernel: usb 1-7: New USB device strings: Mfr=1, Product=2, SerialNumber=3 Jun 2 20:14:35 localhost kernel: usb 1-7: Product: 802.11 g WLAN Jun 2 20:14:35 localhost kernel: usb 1-7: Manufacturer: Ralink Jun 2 20:14:35 localhost kernel: usb 1-7: SerialNumber: 1.0 Jun 2 20:14:35 localhost kernel: Registered led device: rt2800usb-phy3::radio Jun 2 20:14:35 localhost kernel: Registered led device: rt2800usb-phy3::assoc Jun 2 20:14:35 localhost kernel: Registered led device: rt2800usb-phy3::quality Jun 2 20:14:35 localhost NetworkManager[1367]: <info> found WiFi radio killswitch rfkill3 (at /sys/devices/pci0000:00/0000:00:1d.7/usb1/1-7/1-7:1.0/ieee80211/phy3/rfkill3) (driver <unknown>) Jun 2 20:14:35 localhost kernel: rt2800usb 1-7:1.0: firmware: requesting rt2870.bin Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): driver supports SSID scans (scan_capa 0x01). Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): new 802.11 WiFi device (driver: 'rt2800usb' ifindex: 6) Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): exported as /org/freedesktop/NetworkManager/Devices/4 Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): now managed Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): device state change: 1 -> 2 (reason 2) Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): bringing up device. Jun 2 20:14:35 localhost kernel: ADDRCONF(NETDEV_UP): wlan0: link is not ready Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): preparing device. Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): deactivating device (reason: 2). Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): supplicant interface state: starting -> ready Jun 2 20:14:35 localhost NetworkManager[1367]: <info> (wlan0): device state change: 2 -> 3 (reason 42) [root@localhost log]# iwconfig lo no wireless extensions. eth0 no wireless extensions. wlan0 IEEE 802.11bg Mode:Managed Access Point: Not-Associated Tx-Power=8 dBm Retry long limit:7 RTS thr:off Fragment thr:off Encryption key:off Power Management:on

    Read the article

  • Ubuntu hardware wireless switch has no effect after suspend and 13.10 upgrade

    - by blaineh
    I'm posting this on SU after it stalled on askubuntu. I hope someone here can help! If you'd prefer to answer on AU itself, here's the link: http://askubuntu.com/questions/365177/hardware-wireless-switch-has-no-effect-after-suspend-and-13-10-upgrade Wireless works fine after a reboot, but after a suspend the hardware switch (for my laptop this is f12) has no effect on the wireless, it is just permanently off, and shows that it is with a red LED. My rfkill list all reads: 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: yes Any combination with rfkill <un>block wifi doesn't work, although one time first blocking then unblocking actually turned it on again. sudo lshw -C network reads: *-network DISABLED description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Qualcomm Atheros physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 01 serial: 78:e4:00:65:2e:3f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.11.0-12-generic firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:90100000-9010ffff *-network DISABLED description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 02 serial: c8:0a:a9:89:b4:30 size: 10Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:42 ioport:2000(size=256) memory:90010000-90010fff memory:90000000-9000ffff memory:90020000-9002ffff Also, adding a /etc/pm/sleep.d/brcm.sh file as recommended here simply prevents the laptop from suspending at all, which of course is no good. This question has an answer urging to install the original driver, but it wasn't an "accepted answer" so I'd rather not take a chance on it. Also I'll admit I'm a bit lost on that and would like help doing so with the specific information I've given. I would be happy to provide more information, so long as you're willing to help me find it for you! This is a very annoying bug. I have a Compaq Presario CQ62. Edit. Output of lspci | grep Network: 02:00.0 Network controller: Qualcomm Atheros AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Edit. This morning, I had had the laptop suspended all night, and then when I tried to awake it, it simply wouldn't. It would try, and then it would sleep again (I guess it felt a little bit like me! </badjoke>). Is it possible these problems are related? Edit. I don't have enough reputation on SU proper to post links to pastebins and other questions I've tried, so I'm putting them in comments, and of course they're available in the original question.

    Read the article

  • Too many Bind query (cache) denied, DNS attack?

    - by Jake
    Once Bind crashed and I did: tail -f /var/log/messages I see a massive number of logs every second. Is this a DNS attack? or is there something wrong? Sometimes I see a domain in logs like this: dOmAin.com (upper and lower). As you see there is only one single domain in the logs with different IPs Oct 10 02:21:26 mail named[20831]: client 74.125.189.18#38921: query (cache) 'ns1.domain2.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 192.221.144.171#38833: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 74.125.189.17#42428: query (cache) 'ns2.domain2.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 192.221.146.27#37899: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 193.203.82.66#39263: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 8.0.16.170#59723: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 80.169.197.66#32903: query (cache) 'dOmAin.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 134.58.60.1#47558: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 192.221.146.34#47387: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 8.0.16.8#59392: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 74.125.189.19#64395: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 217.72.163.3#42190: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 83.146.21.252#22020: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 192.221.146.116#57342: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 193.203.82.66#52020: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 8.0.16.72#64317: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 80.169.197.66#31989: query (cache) 'dOmAin.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 74.125.189.18#47436: query (cache) 'ns2.domain2.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 74.125.189.16#44005: query (cache) 'ns1.domain2.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 85.132.31.10#50379: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 94.241.128.3#60106: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 85.132.31.10#59118: query (cache) 'domain.com/A/IN' denied Oct 10 02:21:26 mail named[20831]: client 212.95.135.78#27811: query (cache) 'domain.com/A/IN' denied /etc/resolv.conf ; generated by /sbin/dhclient-script nameserver 4.2.2.4 nameserver 8.8.4.4 Bind config: // generated by named-bootconf.pl options { directory "/var/named"; /* * If there is a firewall between you and nameservers you want * to talk to, you might need to uncomment the query-source * directive below. Previous versions of BIND always asked * questions using port 53, but BIND 8.1 uses an unprivileged * port by default. */ // query-source address * port 53; allow-transfer { none; }; allow-recursion { localnets; }; //listen-on-v6 { any; }; notify no; }; // // a caching only nameserver config // controls { inet 127.0.0.1 allow { localhost; } keys { rndckey; }; }; zone "." IN { type hint; file "named.ca"; }; zone "localhost" IN { type master; file "localhost.zone"; allow-update { none; }; }; zone "0.0.127.in-addr.arpa" IN { type master; file "named.local"; allow-update { none; }; };

    Read the article

< Previous Page | 333 334 335 336 337 338 339 340 341 342 343 344  | Next Page >