Search Results

Search found 10397 results on 416 pages for 'mobile devices'.

Page 396/416 | < Previous Page | 392 393 394 395 396 397 398 399 400 401 402 403  | Next Page >

  • wireless internet in linux is very very slow... but in windows.... everythnings fine

    - by Cody Acer
    yesterday when i was connecting to our neighbors wifi connection which is the signal strength is below 50%, i cant browse anything... even ping to gateway. 100% packet loss, and sometimes.. i can connect awesomely i can open my facebook account for 15 minutes but after 15min.. connection is extremely slow. but not windows i can surf even the signal str is very poor weird ey??.. root@Emely:~# lspci -knn 00:00.0 Host bridge [0600]: Intel Corporation Atom Processor D4xx/D5xx/N4xx/N5xx DMI Bridge [8086:a010] Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: agpgart-intel 00:02.0 VGA compatible controller [0300]: Intel Corporation Atom Processor D4xx/D5xx/N4xx/N5xx Integrated Graphics Controller [8086:a011] Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: i915 Kernel modules: i915 00:02.1 Display controller [0380]: Intel Corporation Atom Processor D4xx/D5xx/N4xx/N5xx Integrated Graphics Controller [8086:a012] Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] 00:1b.0 Audio device [0403]: Intel Corporation NM10/ICH7 Family High Definition Audio Controller [8086:27d8] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: snd_hda_intel Kernel modules: snd-hda-intel 00:1c.0 PCI bridge [0604]: Intel Corporation NM10/ICH7 Family PCI Express Port 1 [8086:27d0] (rev 02) Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.1 PCI bridge [0604]: Intel Corporation NM10/ICH7 Family PCI Express Port 2 [8086:27d2] (rev 02) Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.2 PCI bridge [0604]: Intel Corporation NM10/ICH7 Family PCI Express Port 3 [8086:27d4] (rev 02) Kernel driver in use: pcieport Kernel modules: shpchp 00:1c.3 PCI bridge [0604]: Intel Corporation NM10/ICH7 Family PCI Express Port 4 [8086:27d6] (rev 02) Kernel driver in use: pcieport Kernel modules: shpchp 00:1d.0 USB controller [0c03]: Intel Corporation NM10/ICH7 Family USB UHCI Controller #1 [8086:27c8] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: uhci_hcd 00:1d.1 USB controller [0c03]: Intel Corporation NM10/ICH7 Family USB UHCI Controller #2 [8086:27c9] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: uhci_hcd 00:1d.2 USB controller [0c03]: Intel Corporation NM10/ICH7 Family USB UHCI Controller #3 [8086:27ca] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: uhci_hcd 00:1d.3 USB controller [0c03]: Intel Corporation NM10/ICH7 Family USB UHCI Controller #4 [8086:27cb] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: uhci_hcd 00:1d.7 USB controller [0c03]: Intel Corporation NM10/ICH7 Family USB2 EHCI Controller [8086:27cc] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: ehci-pci 00:1e.0 PCI bridge [0604]: Intel Corporation 82801 Mobile PCI Bridge [8086:2448] (rev e2) 00:1f.0 ISA bridge [0601]: Intel Corporation NM10 Family LPC Controller [8086:27bc] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: lpc_ich Kernel modules: lpc_ich 00:1f.2 SATA controller [0106]: Intel Corporation NM10/ICH7 Family SATA Controller [AHCI mode] [8086:27c1] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: ahci Kernel modules: ahci 00:1f.3 SMBus [0c05]: Intel Corporation NM10/ICH7 Family SMBus Controller [8086:27da] (rev 02) Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel modules: i2c-i801 05:00.0 Network controller [0280]: Broadcom Corporation BCM4313 802.11bgn Wireless Network Adapter [14e4:4727] (rev 01) Subsystem: Wistron NeWeb Corp. Device [185f:051a] Kernel driver in use: bcma-pci-bridge Kernel modules: bcma 09:00.0 Ethernet controller [0200]: Marvell Technology Group Ltd. 88E8040 PCI-E Fast Ethernet Controller [11ab:4354] Subsystem: Samsung Electronics Co Ltd Notebook N150P [144d:c072] Kernel driver in use: sky2 Kernel modules: sky2 root@Emely:~# ip addr show 1: lo: mtu 65536 qdisc noqueue state UNKNOWN link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: eth0: mtu 1500 qdisc pfifo_fast state DOWN qlen 1000 link/ether e8:11:32:2e:a6:fd brd ff:ff:ff:ff:ff:ff 3: wlan0: mtu 1500 qdisc mq state UP qlen 1000 link/ether 00:1b:b1:a9:ac:e0 brd ff:ff:ff:ff:ff:ff inet 192.168.1.108/24 brd 192.168.1.255 scope global wlan0 inet6 fe80::21b:b1ff:fea9:ace0/64 scope link valid_lft forever preferred_lft forever root@Emely:~# ip link show 1: lo: mtu 65536 qdisc noqueue state UNKNOWN link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 2: eth0: mtu 1500 qdisc pfifo_fast state DOWN qlen 1000 link/ether e8:11:32:2e:a6:fd brd ff:ff:ff:ff:ff:ff 3: wlan0: mtu 1500 qdisc mq state UP qlen 1000 link/ether 00:1b:b1:a9:ac:e0 brd ff:ff:ff:ff:ff:ff root@Emely:~# rfkill list all 0: samsung-wlan: Wireless LAN Soft blocked: no Hard blocked: no 1: samsung-bluetooth: Bluetooth Soft blocked: no Hard blocked: no 2: hci0: Bluetooth Soft blocked: no Hard blocked: no 3: phy0: Wireless LAN Soft blocked: no Hard blocked: no is this a wireless driver issue?

    Read the article

  • Unable to connect to OpenVPN server

    - by Incognito
    I'm trying to get a working setup of OpenVPN on my VM and authenticate into it from a client. I'm not sure but it looks to me like it's socket related, as it's not set to LISTEN, and localhost seems wrong. I've never set up VPN before. # netstat -tulpn | grep vpn Proto Recv-Q Send-Q Local Address Foreign Address State PID/Program name udp 0 0 127.0.0.1:1194 0.0.0.0:* 24059/openvpn I don't think this is set up correctly. Here's some detail into what I've done. I have a VPS from MediaTemple: These are my interfaces before starting openvpn: lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:39482 errors:0 dropped:0 overruns:0 frame:0 TX packets:39482 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:3237452 (3.2 MB) TX bytes:3237452 (3.2 MB) venet0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:127.0.0.1 P-t-P:127.0.0.1 Bcast:0.0.0.0 Mask:255.255.255.255 UP BROADCAST POINTOPOINT RUNNING NOARP MTU:1500 Metric:1 RX packets:4885284 errors:0 dropped:0 overruns:0 frame:0 TX packets:4679884 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:835278537 (835.2 MB) TX bytes:1989289617 (1.9 GB) venet0:0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:205.[redacted] P-t-P:205.186.148.82 Bcast:0.0.0.0 Mask:255.255.255.255 UP BROADCAST POINTOPOINT RUNNING NOARP MTU:1500 Metric:1 I've followed this guide on setting up a basic server and getting a .p12 file, however, I was receiving an error that stated /dev/net/tun was missing, so I created it mkdir -p /dev/net mknod /dev/net/tun c 10 200 chmod 600 /dev/net/tun This resolved the error preventing the service from launching, however, I am unable to connect. On the server I've set up the myserver.conf file (as per the tutorial) to indicate local 127.0.0.1 (I've also attempted with the public IP address, perhaps I don't understand what they mean by local IP?). The server launches without error, this is what the log looks like when it starts: Sun Apr 1 17:21:27 2012 OpenVPN 2.1.3 x86_64-pc-linux-gnu [SSL] [LZO2] [EPOLL] [PKCS11] [MH] [PF_INET6] [eurephia] built on Mar 11 2011 Sun Apr 1 17:21:27 2012 IMPORTANT: OpenVPN's default port number is now 1194, based on an official port number assignment by IANA. OpenVPN 2.0-beta16 and earlier used 5000 as the default port. Sun Apr 1 17:21:27 2012 NOTE: the current --script-security setting may allow this configuration to call user-defined scripts Sun Apr 1 17:21:27 2012 /usr/bin/openssl-vulnkey -q -b 1024 -m <modulus omitted> Sun Apr 1 17:21:27 2012 TUN/TAP device tun0 opened Sun Apr 1 17:21:27 2012 /sbin/ifconfig tun0 10.8.0.1 pointopoint 10.8.0.2 mtu 1500 Sun Apr 1 17:21:27 2012 GID set to openvpn Sun Apr 1 17:21:27 2012 UID set to openvpn Sun Apr 1 17:21:27 2012 UDPv4 link local (bound): [AF_INET]127.0.0.1:1194 Sun Apr 1 17:21:27 2012 UDPv4 link remote: [undef] Sun Apr 1 17:21:27 2012 Initialization Sequence Completed This creates a tun0 interface that looks like this: tun0 Link encap:UNSPEC HWaddr 00-00-00-00-00-00-00-00-00-00-00-00-00-00-00-00 inet addr:10.8.0.1 P-t-P:10.8.0.2 Mask:255.255.255.255 UP POINTOPOINT RUNNING NOARP MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) And the netstat command still indicates the state is not set to LISTEN. On the client-side I've installed the p12 certs onto two devices (one is an android tablet, the other is an Ubuntu desktop). I don't see port 1194 as open either. Both clients install the cert files and then ask me for the L2TP secret (which was set on the file), but then they oddly ask me for a username and a password, which I don't know where I could possibly get those from. I attempted all of my logins, and some whacky guesses that were frantically pulling at straws. If there's any more information I could provide let me know.

    Read the article

  • Users loggin to 3Com switches authenticated by radius not getting admin priv and no access available

    - by 3D1L
    Hi, Following the setup that I have for my Cisco devices, I got some basic level of functionality authenticating users that loggin to 3Com switches authenticated against a RADIUS server. Problem is that I can not get the user to obtain admin privileges. I'm using Microsoft's IAS service. According to 3Com documentation when configuring the access policy on IAS the value of 010600000003 have to be used to specify admin access level. That value have to be input in the Dial-in profile section: 010600000003 - indicates admin privileges 010600000002 - manager 010600000001 - monitor 010600000000 - visitor Here is the configuration on the switch: radius scheme system server-type standard primary authentication XXX.XXX.XXX.XXX accounting optional key authentication XXXXXX key accounting XXXXXX domain system scheme radius-scheme system local-user admin service-type ssh telnet terminal level 3 local-user manager service-type ssh telnet terminal level 2 local-user monitor service-type ssh telnet terminal level 1 The configuration is working with the IAS server because I can check user login events with the Eventviewer tool. Here is the output of the DISPLAY RADIUS command at the switch: [4500]disp radius SchemeName =system Index=0 Type=standard Primary Auth IP =XXX.XXX.XXX.XXX Port=1645 State=active Primary Acct IP =127.0.0.1 Port=1646 State=active Second Auth IP =0.0.0.0 Port=1812 State=block Second Acct IP =0.0.0.0 Port=1813 State=block Auth Server Encryption Key= XXXXXX Acct Server Encryption Key= XXXXXX Accounting method = optional TimeOutValue(in second)=3 RetryTimes=3 RealtimeACCT(in minute)=12 Permitted send realtime PKT failed counts =5 Retry sending times of noresponse acct-stop-PKT =500 Quiet-interval(min) =5 Username format =without-domain Data flow unit =Byte Packet unit =1 Total 1 RADIUS scheme(s). 1 listed Here is the output of the DISPLAY DOMAIN and DISPLAY CONNECTION commands after users log into the switch: [4500]display domain 0 Domain = system State = Active RADIUS Scheme = system Access-limit = Disable Domain User Template: Idle-cut = Disable Self-service = Disable Messenger Time = Disable Default Domain Name: system Total 1 domain(s).1 listed. [4500]display connection Index=0 ,Username=admin@system IP=0.0.0.0 Index=2 ,Username=user@system IP=xxx.xxx.xxx.xxx On Unit 1:Total 2 connections matched, 2 listed. Total 2 connections matched, 2 listed. [4500] Here is the DISP RADIUS STATISTICS: [4500] %Apr 2 00:23:39:957 2000 4500 SHELL/5/LOGIN:- 1 - ecajigas(xxx.xxx.xxx.xxx) in un it1 logindisp radius stat state statistic(total=1048): DEAD=1046 AuthProc=0 AuthSucc=0 AcctStart=0 RLTSend=0 RLTWait=2 AcctStop=0 OnLine=2 Stop=0 StateErr=0 Received and Sent packets statistic: Unit 1........................................ Sent PKT total :4 Received PKT total:1 Resend Times Resend total 1 1 2 1 Total 2 RADIUS received packets statistic: Code= 2,Num=1 ,Err=0 Code= 3,Num=0 ,Err=0 Code= 5,Num=0 ,Err=0 Code=11,Num=0 ,Err=0 Running statistic: RADIUS received messages statistic: Normal auth request , Num=1 , Err=0 , Succ=1 EAP auth request , Num=0 , Err=0 , Succ=0 Account request , Num=1 , Err=0 , Succ=1 Account off request , Num=0 , Err=0 , Succ=0 PKT auth timeout , Num=0 , Err=0 , Succ=0 PKT acct_timeout , Num=3 , Err=1 , Succ=2 Realtime Account timer , Num=0 , Err=0 , Succ=0 PKT response , Num=1 , Err=0 , Succ=1 EAP reauth_request , Num=0 , Err=0 , Succ=0 PORTAL access , Num=0 , Err=0 , Succ=0 Update ack , Num=0 , Err=0 , Succ=0 PORTAL access ack , Num=0 , Err=0 , Succ=0 Session ctrl pkt , Num=0 , Err=0 , Succ=0 RADIUS sent messages statistic: Auth accept , Num=0 Auth reject , Num=0 EAP auth replying , Num=0 Account success , Num=0 Account failure , Num=0 Cut req , Num=0 RecError_MSG_sum:0 SndMSG_Fail_sum :0 Timer_Err :0 Alloc_Mem_Err :0 State Mismatch :0 Other_Error :0 No-response-acct-stop packet =0 Discarded No-response-acct-stop packet for buffer overflow =0 The other problem is that when the RADIUS server is not available I can not log in to the switch. The switch have 3 local accounts but none of them works. How can I specify the switch to use the local accounts in case that the RADIUS service is not available?

    Read the article

  • Issue in setting up VPN connection (IKEv1) using android (ICS vpn client) with Strongswan 4.5.0 server

    - by Kushagra Bhatnagar
    I am facing issues in setting up VPN connection(IKEv1) using android (ICS vpn client) and Strongswan 4.5.0 server. Below is the set up: Strongswan server is running on ubuntu linux machine which is connected to some wifi hotspot. Using the steps in this guide link, I generated CA, server and client certificate. Once certificates are generated, following (clientCert.p12 and caCert.pem) are sent to mobile via mail and installed on android device. Below are the ip addresses assigned to various interfaces Linux server wlan0 interface ip where server is running: 192.168.43.212, android device eth0 interface ip address: 192.168.43.62; Android device is also attached with the same wifi hotspot. On the Android device, I uses IPsec Xauth RSA option for setting up VPN authentication configuration. I am using the following ipsec.conf configuration: # basic configuration config setup plutodebug=all # crlcheckinterval=600 # strictcrlpolicy=yes # cachecrls=yes nat_traversal=yes # charonstart=yes plutostart=yes # Add connections here. # Sample VPN connections conn ios1 keyexchange=ikev1 authby=xauthrsasig xauth=server left=%defaultroute leftsubnet=0.0.0.0/0 leftfirewall=yes leftcert=serverCert.pem right=192.168.43.62 rightsubnet=10.0.0.0/24 rightsourceip=10.0.0.2 rightcert=clientCert.pem pfs=no auto=add      With the above configurations when I enable VPN on android device, VPN connection is not successful and it gets timed out in Authentication phase. I ran wireshark on both the android device and strongswan server, from the tcpdump below are the observations. Initially Identity Protection (Main mode) exchanges happens between device and server and all are successful. After all successful Identity Protection (Main mode) exchanges server is sending Transaction (Config mode) to device. In reply android device is sending Informational message instead of Transaction (Config mode) message. Further server is keep on sending Transaction (Config mode) message and device is again sending Identity Protection (Main mode) messages. Finally timeout happens and connection fails. I also capture Strongswan server logs and below are the snippets from the server logs which also verifies the same(described above). Apr 27 21:09:40 Linux pluto[12105]: | **parse ISAKMP Message: Apr 27 21:09:40 Linux pluto[12105]: | initiator cookie: Apr 27 21:09:40 Linux pluto[12105]: | 06 fd 61 b8 86 82 df ed Apr 27 21:09:40 Linux pluto[12105]: | responder cookie: Apr 27 21:09:40 Linux pluto[12105]: | 73 7a af 76 74 f0 39 8b Apr 27 21:09:40 Linux pluto[12105]: | next payload type: ISAKMP_NEXT_HASH Apr 27 21:09:40 Linux pluto[12105]: | ISAKMP version: ISAKMP Version 1.0 Apr 27 21:09:40 Linux pluto[12105]: | exchange type: ISAKMP_XCHG_INFO Apr 27 21:09:40 Linux pluto[12105]: | flags: ISAKMP_FLAG_ENCRYPTION Apr 27 21:09:40 Linux pluto[12105]: | message ID: a2 80 ad 82 Apr 27 21:09:40 Linux pluto[12105]: | length: 92 Apr 27 21:09:40 Linux pluto[12105]: | ICOOKIE: 06 fd 61 b8 86 82 df ed Apr 27 21:09:40 Linux pluto[12105]: | RCOOKIE: 73 7a af 76 74 f0 39 8b Apr 27 21:09:40 Linux pluto[12105]: | peer: c0 a8 2b 3e Apr 27 21:09:40 Linux pluto[12105]: | state hash entry 25 Apr 27 21:09:40 Linux pluto[12105]: | state object not found Apr 27 21:09:40 Linux pluto[12105]: packet from 192.168.43.62:500: Informational Exchange is for an unknown (expired?) SA Apr 27 21:09:40 Linux pluto[12105]: | next event EVENT_RETRANSMIT in 10 seconds for #9 Can anyone please provide update on this issue. Why the VPN connection gets timed out and why the ISAKMP exchanges are not proper between Android and strongswan server.

    Read the article

  • DNS lookups failing somewhere between firewall and router

    - by TessellatingHeckler
    we have a setup of ADSL line - Cisco 837 ADSL router - Zyxel ZyWall 35 firewall/NAT - Switch == Intel load balanced NICS in a server. It has been fine for years, suddenly DNS resolution stopped working on the server. No changes that I know of, so I can't work backwards from there. It was configured with the ISP's DNS servers, neither network device does DNS relaying. Wireshark shows the request go out but nothing comes back. The server networking stack seems OK though, because if we query an internal DNS server on a remote site, that works. I can logon to the Cisco, and DNS resolves OK from the command line. I can logon to the ZyWall, and DNS does not resolve from the command line. So the problem seems to be the firewall, patch cable or router, yes? On the router: interface Ethernet0 ip address aaa.bbb.ccc.ddd 255.255.255.ddd ip tcp adjust-mss 1450 hold-queue 100 out On the firewall: DNS server set to 8.8.8.8 (Google's), DNS traffic allowed LAN-WAN. What else should I look for? Update: Following This guide I've got traffic logging on the Cisco. I have also got access to a public DNS server which I can run tcpdump on to see things from the other side. And as per the below comments, I've tested with Dig and see that DNS over TCP works, and over UDP does not. Currently: DNS request from the server using TCP shows up in the firewall log, and in the Cisco log, and in tcpdump on the DNS server, the answer comes back, it works fine. DNS request from the server using UDP shows up in the firewall log, and in the Cisco log, does NOT show in tcpdump on the DNS server, times out. DNS request from the cisco (using UDP) does show up in tcpdump on the DNS server, answer received, works fine. Ping requests from the server and the cisco to the DNS server show up in tcpdump on the DNS server. DNS request from the server using UDP does show up on the firewall. Summary: TCP seems fine throughought. UDP works over the ADSL and to the Cisco, and it works from the server to the Cisco, but it doesn't cross the Cisco properly, it seems. I did see the Cisco showing as connected at 10Mb/full-duplex internally, and the firewall showing as 100Mb/full-duplex externally. I have forced the firewall to 10Mb and rebooted both devices. That seemed to help get UDP traffic (server-firewall-cisco) instead of (server-firewall), but did not fix it. Update: Sanitized Cisco config: version 12.2 no service pad service timestamps debug datetime msec service timestamps log datetime msec service password-encryption ! hostname cisco ! logging queue-limit 100 enable secret 5 {password} enable password 7 {password} ! ip subnet-zero ip domain name example.org ip name-server {nameserver_IP} ! ! ip audit notify log ip audit po max-events 100 no ftp-server write-enable ! interface Ethernet0 ip address {Inside_public_IP} 255.255.255.248 ip tcp adjust-mss 1460 hold-queue 100 out ! interface ATM0 no ip address no atm ilmi-keepalive pvc 0/38 encapsulation aal5mux ppp dialer dialer pool-member 1 ! dsl operating-mode auto ! interface Dialer1 ip unnumbered Ethernet0 encapsulation ppp dialer pool 1 dialer idle-timeout 0 dialer persistent no cdp enable ppp chap hostname {ADSL_Username} ppp chap password 7 {ADSL_Password} ! ip classless ip route 0.0.0.0 0.0.0.0 Dialer1 no ip http server no ip http secure-server ! access-list 23 permit {IP} dialer-list 1 protocol ip permit no cdp run snmp-server enable traps tty ! {con, vty} end

    Read the article

  • TV not detected by Windows/VGA - when there is a WHDI device in the signal chain

    - by ashwalk
    I'm at my wit's end with this one... I had an EVGA GTS 250, and I used to plug it's HDMI out into a WHDI sender, which transmitted to its corresponding WHDI receiver 15ft away, which then connected to a Samsung LN40D LCD TV through another HDMI cable. PC/VGA < [hdmi cable] < WHDI sender <[air] WHDI receiver < [hdmi cable] < TV It was perfect, stable, no perceivable latency. I just plugged everything the first time and it worked instantly. It sent 5.1 audio, and Windows/nVidia Control Center detected the TV by its name. The WHDI device is this one: http://goo.gl/Q8iWI5 Now I bought an EVGA GTX 650, and WHDI doesn't work anymore. Both Windows and nVidia Control Center won't detect the TV, only the monitor that's connected via DVI. The TV screen shows "TX202913 connected. Check video signal." on top of a black screen. Though the device is not the problem itself, just the fact that it's not allowing direct connection between PC and TV. I would bet that if put an AVR in its place I'd also have this issue. The HDMI on this new card works with other monitors. If I put the older card back, WHDI works normally. I have googled this for 5 months on and off. Once I bumped into a page that showed how to force a display device to always-on through registry edit. Once I restarted windows, the Tv (through WHDI) displayed my expanded or duplicated desktop at 1024x768 ONLY, and listed the display as "digital display". I could not change the resolution and it wouldn't playback audio (although the option was available at nVidia Control Center HDMI audio options, but did not work). This proves that there is no conflict between the devices, except that software-wise, Windows cannot, for the life of it, understand that there's a TV there to send video/audio to. Since this won't do (no audio, poor video), I reverted this regedit. It's also not an EDID problem within the TV, since when connected directly it works. The last weird bit of this saga is that today, I reminded of Windows' "Add Device" dialog, gave it a go, and a "Samsung Generic UPNP TV" showed up, which I promptly installed the drives for, rising to a climax of... ...NOTHING HAPPENING. As far as I can tell, it really didn't change anything other than using up a few kb in my main disc. I should also say that I looked a LOT into handshake problems and nothing applied either. Do any of you have an idea of what may be going on? I can't stand the thought of having a us$200 device not working because of the addition of a newer graphics card, when the much older one had no issues. There is absolutely NO REASON for this to happen. There is NO documentation on WHDI online. Apparently no one buys this stuff. For the same reason, no one responded to this same plea for help on NVidia and EVGA forums. Worst case, this can be a warning about this setup for people in the future. Thanx in advance.

    Read the article

  • Facing issues in setting up VPN connection(IKEv1) using iphone (Defult Cisco VPN client) and Strongswan 4.5.0 server

    - by Kushagra Bhatnagar
    I am facing issues in setting up VPN connection(IKEv1) using iPhone (Defult Cisco VPN client) and Strongswan 4.5.0 server. The Strongswan server is running on Ubuntu Linux, which is connected to some wifi hotspot. This is the guide which was used. I generated CA, server and client certificate, with the only difference mentioned below. “While generating server certificate, as per link CN=vpn.strongswan.org instead of this I changed CN name to CN=192.168.43.212.” Once certificates are generated, following (clientCert.p12 and caCert.pem) are sent to mobile via mail and installed on iphone. After installation I notice that certificates are considered as trusted also. Below are the ip addresses assigned to various interfaces Linux server wlan0 interface ip where server is running: 192.168.43.212 Iphone eth0 interface ip address: 192.168.43.72. iphone is also attached with the same wifi hotspot. Below is the snapshot of client configurations. Description Strong swan Server 192.168.43.212 Account ipsecvpn Password ***** Use certificate ON Certificate client The above username and password are in sync with the ipsec.secrets file. I am using the following ipsec.conf configuration: # basic configuration config setup plutodebug=all # crlcheckinterval=600 # strictcrlpolicy=yes # cachecrls=yes nat_traversal=yes # charonstart=yes plutostart=yes # Add connections here. # Sample VPN connections conn ios1 keyexchange=ikev1 authby=xauthrsasig xauth=server left=%defaultroute leftsubnet=0.0.0.0/0 leftfirewall=yes leftcert=serverCert.pem right=192.168.43.72 rightsubnet=10.0.0.0/24 rightsourceip=10.0.0.2 rightcert=clientCert.pem pfs=no auto=add With the above configurations when I enable VPN on iphone, it says Could not able to verify server certificate. I ran Wireshark on a Linux server and observe that initially some ISAKMP message exchanges happens between client and server, which are successful but before authorization, client is sending some informational message and soon after this client is showing error as popup Could not able to verify server certificate. Capture logs on Strongswan server and in server logs below errors are observed: From auth.log Apr 25 20:16:08 Linux pluto[4025]: | ISAKMP version: ISAKMP Version 1.0 Apr 25 20:16:08 Linux pluto[4025]: | exchange type: ISAKMP_XCHG_INFO Apr 25 20:16:08 Linux pluto[4025]: | flags: ISAKMP_FLAG_ENCRYPTION Apr 25 20:16:08 Linux pluto[4025]: | message ID: 9d 1a ea 4d Apr 25 20:16:08 Linux pluto[4025]: | length: 76 Apr 25 20:16:08 Linux pluto[4025]: | ICOOKIE: f6 b7 06 b2 b1 84 5b 93 Apr 25 20:16:08 Linux pluto[4025]: | RCOOKIE: 86 92 a0 c2 a6 2f ac be Apr 25 20:16:08 Linux pluto[4025]: | peer: c0 a8 2b 48 Apr 25 20:16:08 Linux pluto[4025]: | state hash entry 8 Apr 25 20:16:08 Linux pluto[4025]: | state object not found Apr 25 20:16:08 Linux pluto[4025]: **packet from 192.168.43.72:500: Informational Exchange is for an unknown (expired?) SA** Apr 25 20:16:08 Linux pluto[4025]: | next event EVENT_RETRANSMIT in 8 seconds for #8 Apr 25 20:16:16 Linux pluto[4025]: | Apr 25 20:16:16 Linux pluto[4025]: | *time to handle event Apr 25 20:16:16 Linux pluto[4025]: | event after this is EVENT_RETRANSMIT in 2 seconds Apr 25 20:16:16 Linux pluto[4025]: | handling event EVENT_RETRANSMIT for 192.168.43.72 "ios1" #8 Apr 25 20:16:16 Linux pluto[4025]: | sending 76 bytes for EVENT_RETRANSMIT through wlan0 to 192.168.43.72:500: Apr 25 20:16:16 Linux pluto[4025]: | a6 a5 86 41 4b fb ff 99 c9 18 34 61 01 7b f1 d9 Apr 25 20:16:16 Linux pluto[4025]: | 08 10 06 01 e9 1c ea 60 00 00 00 4c ba 7d c8 08 Apr 25 20:16:16 Linux pluto[4025]: | 13 47 95 18 19 31 45 30 2e 22 f9 4d 85 2c 27 bc Apr 25 20:16:16 Linux pluto[4025]: | 9e 9b e1 ae 1e 35 51 6f ab 80 f5 73 3c 15 8d 20 Apr 25 20:16:16 Linux pluto[4025]: | 4b 46 47 86 50 24 3f 13 15 7d d5 17 Apr 25 20:16:16 Linux pluto[4025]: | inserting event EVENT_RETRANSMIT, timeout in 40 seconds for #8 Apr 25 20:16:16 Linux pluto[4025]: | next event EVENT_RETRANSMIT in 2 seconds for #10 Apr 25 20:16:16 Linux pluto[4025]: | rejected packet: Apr 25 20:16:16 Linux pluto[4025]: | Apr 25 20:16:16 Linux pluto[4025]: | control: Apr 25 20:16:16 Linux pluto[4025]: | 30 00 00 00 00 00 00 00 00 00 00 00 0b 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | 6f 00 00 00 02 03 03 00 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | 02 00 00 00 c0 a8 2b 48 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: | name: Apr 25 20:16:16 Linux pluto[4025]: | 02 00 01 f4 c0 a8 2b 48 00 00 00 00 00 00 00 00 Apr 25 20:16:16 Linux pluto[4025]: **ERROR: asynchronous network error report on wlan0 for message to 192.168.43.72 port 500, complainant 192.168.43.72: Connection refused [errno 111, origin ICMP type 3 code 3 (not authenticated)]** Anybody please provide some update about this error and how to solve this issue.

    Read the article

  • Windows can see Ubuntu Server printer, but can't print to it

    - by Mike
    I have an old desktop that I'm trying to set up as a home backup/print server. Backup was trivial, but am having issues getting the printing to work. The printer is connected to the server running Ubuntu Server 9.10 (no gui). If I access the printer via http://hostname:631/printers/, I am able to print a test page, so I know the printer is working; however, I am having no luck from Windows. Windows can see the printer when browsed via \hostname\, but I am unable to connect. Windows says "Windows cannot connect to the printer" without indicating why. Any suggestions? From /etc/samba/smb.conf: [global] workgroup = WORKGROUP dns proxy = no security = user username map = /etc/samba/smbusers encrypt passwords = true passdb backend = tdbsam obey pam restrictions = yes unix password sync = yes passwd program = /usr/bin/passwd %u passwd chat = *Enter\snew\s*\spassword:* %n\n *Retype\snew\s*\spassword:* %n\n *password\supdated\ssuccessfully* . pam password change = yes map to guest = bad user load printers = yes printing = cups printcap name = cups [printers] comment = All Printers browseable = no path = /var/spool/samba writable = no printable = yes guest ok = yes read only = yes create mask = 0700 [print$] comment = Printer Drivers path = /var/lib/samba/printers browseable = yes read only = yes guest ok = yes From /etc/cups/cupsd.conf: LogLevel warn SystemGroup lpadmin Port 631 Listen /var/run/cups/cups.sock Browsing On BrowseOrder allow,deny BrowseAllow all BrowseRemoteProtocols CUPS BrowseAddress @LOCAL BrowseLocalProtocols CUPS dnssd DefaultAuthType Basic <Location /> Order allow,deny Allow all </Location> <Location /admin> Order allow,deny Allow all </Location> <Location /admin/conf> AuthType Default Require user @SYSTEM Order allow,deny Allow all </Location> <Policy default> <Limit Send-Document Send-URI Hold-Job Release-Job Restart-Job Purge-Jobs Set-Job-Attributes Create-Job-Subscription Renew-Subscription Cancel-Subscription Get-Notifications Reprocess-Job Cancel-Current-Job Suspend-Current-Job Resume-Job CUPS-Move-Job CUPS-Get-Document> Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit CUPS-Add-Modify-Printer CUPS-Delete-Printer CUPS-Add-Modify-Class CUPS-Delete-Class CUPS-Set-Default CUPS-Get-Devices> AuthType Default Require user @SYSTEM Order deny,allow </Limit> <Limit Pause-Printer Resume-Printer Enable-Printer Disable-Printer Pause-Printer-After-Current-Job Hold-New-Jobs Release-Held-New-Jobs Deactivate-Printer Activate-Printer Restart-Printer Shutdown-Printer Startup-Printer Promote-Job Schedule-Job-After CUPS-Accept-Jobs CUPS-Reject-Jobs> AuthType Default Require user @SYSTEM Order deny,allow </Limit> <Limit CUPS-Authenticate-Job> Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit All> Order deny,allow </Limit> </Policy> <Policy authenticated> <Limit Create-Job Print-Job Print-URI> AuthType Default Order deny,allow </Limit> <Limit Send-Document Send-URI Hold-Job Release-Job Restart-Job Purge-Jobs Set-Job-Attributes Create-Job-Subscription Renew-Subscription Cancel-Subscription Get-Notifications Reprocess-Job Cancel-Current-Job Suspend-Current-Job Resume-Job CUPS-Move-Job CUPS-Get-Document> AuthType Default Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit CUPS-Add-Modify-Printer CUPS-Delete-Printer CUPS-Add-Modify-Class CUPS-Delete-Class CUPS-Set-Default> AuthType Default Require user @SYSTEM Order deny,allow </Limit> <Limit Pause-Printer Resume-Printer Enable-Printer Disable-Printer Pause-Printer-After-Current-Job Hold-New-Jobs Release-Held-New-Jobs Deactivate-Printer Activate-Printer Restart-Printer Shutdown-Printer Startup-Printer Promote-Job Schedule-Job-After CUPS-Accept-Jobs CUPS-Reject-Jobs> AuthType Default Require user @SYSTEM Order deny,allow </Limit> <Limit Cancel-Job CUPS-Authenticate-Job> AuthType Default Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit All> Order deny,allow </Limit> </Policy>

    Read the article

  • Ubuntu 12 crashed and took down network

    - by Leopd
    We recently set up a new Ubuntu 12.04LTS server on our network. It's not fully configured so it's not doing much beyond sshd and a default apache2 install. But this evening it appears to have crashed. It wasn't responding to the network or the keyboard. But the worst part is, it took down the entire network. My knowledge of the network stack below OSI layer 3 is very limited, so the rest confuses me. When this machine was physically connected to the network, no other machine could connect to the outside internet. When things were broken, running arp showed that our gateway's IP address (10.0.1.1) was listed as "invalid." Unplugging the server from the network fixed the problem, and plugging it back in broke it again. So the crashed server was advertising itself as owning the gateway's IP address? There's nothing at all in syslog during the time when it was causing problems. Any ideas about how to figure out what went wrong or what we can do to prevent it from happening again? I'm hesitant to even put the machine back on the network right now. Update ** It crashed again, and I ran tcpdump -penn arp (thanks bahamat!) for several minutes and got this... (timestamps and duplicate lines removed) 00:1e:65:f8:dc:24 > ff:ff:ff:ff:ff:ff, ethertype ARP (0x0806), length 60: Request who-has 10.0.1.1 tell 10.0.2.191, length 46 00:1e:65:f8:dc:24 > ff:ff:ff:ff:ff:ff, ethertype ARP (0x0806), length 60: Request who-has 10.0.1.44 tell 10.0.2.191, length 46 60:d8:19:d4:71:d6 > ff:ff:ff:ff:ff:ff, ethertype ARP (0x0806), length 60: Request who-has 10.0.1.1 tell 10.0.2.125, length 46 d4:9a:20:04:e9:78 > ff:ff:ff:ff:ff:ff, ethertype ARP (0x0806), length 42: Request who-has 192.168.1.1 tell 192.168.1.100, length 28 Update 2 ** When the network is functioning properly, arping -c4 10.0.1.1 returns this: ARPING 10.0.1.1 60 bytes from c0:c1:c0:77:25:8e (10.0.1.1): index=0 time=267.982 usec 60 bytes from c0:c1:c0:77:25:8e (10.0.1.1): index=1 time=422.955 usec 60 bytes from c0:c1:c0:77:25:8e (10.0.1.1): index=2 time=299.215 usec 60 bytes from c0:c1:c0:77:25:8e (10.0.1.1): index=3 time=366.926 usec --- 10.0.1.1 statistics --- 4 packets transmitted, 4 packets received, 0% unanswered (0 extra) When the bad server is plugged in, arping -c4 10.0.1.1 returns: ARPING 10.0.1.1 --- 10.0.1.1 statistics --- 4 packets transmitted, 0 packets received, 100% unanswered (0 extra) Context ** 10.0.x.x is the main subnet. 10.0.1.1 is the main internet gateway 10.0.1.44 is a printer 10.0.2.* devices are all laptops / workstations I have no idea what's using the 192.168.x.x subnet -- your guesses are at least as good as mine. A VM on a workstation? A misconfigured WAP? Somebody re-sharing wifi? A machine that failed to DHCP? The offending ubuntu server's MAC address ends in cd:80 so isn't listed in the dump. It should DHCP to 10.0.3.3 Thanks for any help. This ARP stuff is all voodoo to me. Packets just go to IP addresses, right? ;)

    Read the article

  • Windows 7: How to place SuperFetch cache on an SSD?

    - by Ian Boyd
    I'm thinking of adding a solid state drive (SSD) to my existing Windows 7 installation. I know I can (and should) move my paging file to the SSD: Should the pagefile be placed on SSDs? Yes. Most pagefile operations are small random reads or larger sequential writes, both of which are types of operations that SSDs handle well. In looking at telemetry data from thousands of traces and focusing on pagefile reads and writes, we find that Pagefile.sys reads outnumber pagefile.sys writes by about 40 to 1, Pagefile.sys read sizes are typically quite small, with 67% less than or equal to 4 KB, and 88% less than 16 KB. Pagefile.sys writes are relatively large, with 62% greater than or equal to 128 KB and 45% being exactly 1 MB in size. In fact, given typical pagefile reference patterns and the favorable performance characteristics SSDs have on those patterns, there are few files better than the pagefile to place on an SSD. What I don't know is if I even can put a SuperFetch cache (i.e. ReadyBoost cache) on the solid state drive. I want to get the benefit of Windows being able to cache gigabytes of frequently accessed data on a relativly small (e.g. 30GB) solid state drive. This is exactly what SuperFetch+ReadyBoost (or SuperFetch+ReadyDrive) was designed for. Will Windows offer (or let) me place a ReadyBoost cache on a solid state flash drive connected via SATA? A problem with the ReadyBoost cache over the ReadyDrive cache is that the ReadyBoost cache does not survive between reboots. The cache is encrypted with a per-session key, making its existing contents unusable during boot and SuperFetch pre-fetching during login. Update One I know that Windows Vista limited you to only one ReadyBoost.sfcache file (I do not know if Windows 7 removed that limitation): Q: Can use use multiple devices for EMDs? A: Nope. We've limited Vista to one ReadyBoost per machine Q: Why just one device? A: Time and quality. Since this is the first revision of the feature, we decided to focus on making the single device exceptional, without the difficulties of managing multiple caches. We like the idea, though, and it's under consideration for future versions. I also know that the 4GB limit on the cache file was a limitation of the FAT filesystem used on most USB sticks - an SSD drive would be formatted with NTFS: Q: What's the largest amount of flash that I can use for ReadyBoost? A: You can use up to 4GB of flash for ReadyBoost (which turns out to be 8GB of cache w/ the compression) Q: Why can't I use more than 4GB of flash? A: The FAT32 filesystem limits our ReadyBoost.sfcache file to 4GB Can a ReadyBoost cache on an NTFS volume be larger than 4GB? Update Two The ReadyBoost cache is encrypted with a per-boot session key. This means that the cache has to be re-built after each boot, and cannot be used to help speed boot times, or latency from login to usable. Windows ReadyDrive technology takes advantage of non-volatile (NV) memory (i.e. flash) that is incorporated with some hybrid hard drives. This flash cache can be used to help Windows boot, or resume from hibernate faster. Will Windows 7 use an internal SSD drive as a ReadyBoost/*ReadyDrive*/SuperFetch cache? Is it possible to make Windows store a SuperFetch cache (i.e. ReadyBoost) on a non-removable SSD? Is it possible to not encrypt the ReadyBoost cache, and if so will Windows 7 use the cache at boot time? See also SuperUser.com: ReadyBoost + SSD = ? Windows 7 - ReadyBoost & SSD drives? Support and Q&A for Solid-State Drives Using SDD as a cache for HDD, is there a solution? Performance increase using SSD for paging/fetch/cache or ReadyBoost? (Win7) Windows 7 To Boost SSD Performance How to Disable Nonvolatile Caching

    Read the article

  • Issues with Verizon's "Network Extender" device talking on my home network.

    - by Logan
    I recently switched my phone service to Verizon from ATT, and I get somewhat spotty service in my house. I called them and they sent me a "network extender" device for free. Its a femtocell that connects to my home network. The directions that come with it are very dumbed down, basically just say to connect it to your router and put it near a window (so it can get a GPS signal, it has to make sure its within the correct area before operating). The problem I'm having is the network light on it stays red. The troubleshooting information that came with it tells me this means there is a bad network connection. Its connected through an ASUS router running DD-WRT. No other devices on my network have a problem with it, including a Western Digital WDLIVE device, mine and my wife's cell phones (via wifi), a Wii, and an Xbox. If I connect the device directly to my cable modem, the light goes blue (which means good) and it starts working. So this tells me that its definately a configuration issue with my router. Verizon basically washed their hands of me when I connected it to my cable modem, and told me that its a router issue and to try a different router. Because normal people just have extra routers laying around their houses... When I connect it to the router, I can watch the DHCP Clients list on the status page, and the MAC of the network extender quickly fills up the clients list, grabbing every available DHCP address. Its like it grabs an address, can't connect to the internet, releases it, grabs another, then another, then another. So in the DHCP server settings I assigned a static IP to its MAC. This made it quit doing what it was doing before, but its still not working. I found the ports I needed to open on verizon's website, and opened them in the port forwarding config on my router. This still didn't help. So, I tried setting the network extender device's IP as the DMZ IP on the router. This still did no good. I called Verizon back and got the tech to write up a report which he passed on to a "senior network tech" who I got a call back from a few hours ago. This guy told me that while an ASUS router isn't listed as a supported device, he's not really sure why its not working. He suggested restoring the firmware to stock ASUS firmware and trying again. I have a very hard time believing its DD-WRT doing this, since every other device is working just fine with it. But its also not the Network Extender, since it works just fine when connected directly to the modem. At this point I'm out of ideas, and the next step is to restore the stock firmware on my router, and then going to walmart and getting a linksys WRT-54G to try. Is there anything else I could try before going that drastic? Cliffs- -Network extender won't work behind router, works when connected directly to cable modem. -Extender goes nuts when allowed to pick its own DHCP address, I had to assign it a static IP. -Won't work when correct ports are forwarded to it -Won't work with a DMZ address.

    Read the article

  • How to place SuperFetch cache on an SSD?

    - by Ian Boyd
    I'm thinking of adding a solid state drive (SSD) to my existing Windows 7 installation. I know I can (and should) move my paging file to the SSD: Should the pagefile be placed on SSDs? Yes. Most pagefile operations are small random reads or larger sequential writes, both of which are types of operations that SSDs handle well. In looking at telemetry data from thousands of traces and focusing on pagefile reads and writes, we find that Pagefile.sys reads outnumber pagefile.sys writes by about 40 to 1, Pagefile.sys read sizes are typically quite small, with 67% less than or equal to 4 KB, and 88% less than 16 KB. Pagefile.sys writes are relatively large, with 62% greater than or equal to 128 KB and 45% being exactly 1 MB in size. In fact, given typical pagefile reference patterns and the favorable performance characteristics SSDs have on those patterns, there are few files better than the pagefile to place on an SSD. What I don't know is if I even can put a SuperFetch cache (i.e. ReadyBoost cache) on the solid state drive. I want to get the benefit of Windows being able to cache gigabytes of frequently accessed data on a relativly small (e.g. 30GB) solid state drive. This is exactly what SuperFetch+ReadyBoost (or SuperFetch+ReadyDrive) was designed for. Will Windows offer (or let) me place a ReadyBoost cache on a solid state flash drive connected via SATA? A problem with the ReadyBoost cache over the ReadyDrive cache is that the ReadyBoost cache does not survive between reboots. The cache is encrypted with a per-session key, making its existing contents unusable during boot and SuperFetch pre-fetching during login. Update One I know that Windows Vista limited you to only one ReadyBoost.sfcache file (I do not know if Windows 7 removed that limitation): Q: Can use use multiple devices for EMDs? A: Nope. We've limited Vista to one ReadyBoost per machine Q: Why just one device? A: Time and quality. Since this is the first revision of the feature, we decided to focus on making the single device exceptional, without the difficulties of managing multiple caches. We like the idea, though, and it's under consideration for future versions. I also know that the 4GB limit on the cache file was a limitation of the FAT filesystem used on most USB sticks - an SSD drive would be formatted with NTFS: Q: What's the largest amount of flash that I can use for ReadyBoost? A: You can use up to 4GB of flash for ReadyBoost (which turns out to be 8GB of cache w/ the compression) Q: Why can't I use more than 4GB of flash? A: The FAT32 filesystem limits our ReadyBoost.sfcache file to 4GB Can a ReadyBoost cache on an NTFS volume be larger than 4GB? Update Two The ReadyBoost cache is encrypted with a per-boot session key. This means that the cache has to be re-built after each boot, and cannot be used to help speed boot times, or latency from login to usable. Windows ReadyDrive technology takes advantage of non-volatile (NV) memory (i.e. flash) that is incorporated with some hybrid hard drives. This flash cache can be used to help Windows boot, or resume from hibernate faster. Will Windows 7 use an internal SSD drive as a ReadyBoost/*ReadyDrive*/SuperFetch cache? Is it possible to make Windows store a SuperFetch cache (i.e. ReadyBoost) on a non-removable SSD? Is it possible to not encrypt the ReadyBoost cache, and if so will Windows 7 use the cache at boot time? See also SuperUser.com: ReadyBoost + SSD = ? Windows 7 - ReadyBoost & SSD drives? Support and Q&A for Solid-State Drives Using SDD as a cache for HDD, is there a solution? Performance increase using SSD for paging/fetch/cache or ReadyBoost? (Win7) Windows 7 To Boost SSD Performance How to Disable Nonvolatile Caching

    Read the article

  • php-fpm + persistent sockets = 502 bad gateway

    - by leeoniya
    Put on your reading glasses - this will be a long-ish one. First, what I'm doing. I'm building a web-app interface for some particularly slow tcp devices. Opening a socket to them takes 200ms and an fwrite/fread cycle takes another 300ms. To reduce the need for both of these actions on each request, I'm opening a persistent tcp socket which reduces the response time by the aforementioned 200ms. I was hoping PHP-FPM would share the persistent connections between requests from different clients (and indeed it does!), but there are some issues which I havent been able to resolve after 2 days of interneting, reading logs and modifying settings. I have somewhat narrowed it down though. Setup: Ubuntu 13.04 x64 Server (fully updated) on Linode PHP 5.5.0-6~raring+1 (fpm-fcgi) nginx/1.5.2 Relevent config: nginx worker_processes 4; php-fpm/pool.d pm = dynamic pm.max_children = 2 pm.start_servers = 2 pm.min_spare_servers = 2 Let's go from coarse to fine detail of what happens. After a fresh start I have 4x nginx processes and 2x php5-fpm processes waiting to handle requests. Then I send requests every couple seconds to the script. The first take a while to open the socket connection and returns with the data in about 500ms, the second returns data in 300ms (yay it's re-using the socket), the third also succeeds in about 300ms, the fourth request = 502 Bad Gateway, same with the 5th. Sixth request once again returns data, except now it took 500ms again. The process repeats for several cycles after which every 4 requests result in 2x 502 Bad Gateways and 2x 500ms Data responses. If I double all the fpm pool values and have 4x php-fpm processes running, the cycles settles in with 4x successful 500ms responses followed by 4x Bad Gateway errors. If I don't use persistent sockets, this issue goes away but then every request is 500ms. What I suspect is happening is the persistent socket keeps each php-fpm process from idling and ties it up, so the next one gets chosen until none are left and as they error out, maybe they are restarted and become available on the next round-robin loop ut the socket dies with the process. I haven't yet checked the 'slowlog', but the nginx error log shows lots of this: *188 recv() failed (104: Connection reset by peer) while reading response header from upstream, client:... All the suggestions on the internet regarding fixing nginx/php-fpm/502 bad gateway relate to high load or fcgi_pass misconfiguration. This is not the case here. Increasing buffers/sizes, changing timeouts, switching from unix socket to tcp socket for fcgi_pass, upping connection limits on the system....none of this stuff applies here. I've had some other success with setting pm = ondemand rather than dynamic, but as soon as the initial fpm-process gets killed off after idling, the persistent socket is gone for all subsequent php-fpm spawns. For the php script, I'm using stream_socket_client() with a STREAM_CLIENT_PERSISTENT flag. A while/stream_select() loop to detect socket data and fread($sock, 4096) to grab the data. I don't call fclose() obviously. If anyone has some additional questions or advice on how to get a persistent socket without tying up the php-fpm processes beyond the request completion, or maybe some other things to try, I'd appreciate it. some useful links: Nginx + php-fpm - recv() error Nginx + php-fpm "504 Gateway Time-out" error with almost zero load (on a test-server) Nginx + PHP-FPM "error 104 Connection reset by peer" causes occasional duplicate posts http://www.linuxquestions.org/questions/programming-9/php-pfsockopen-552084/ http://stackoverflow.com/questions/14268018/concurrent-use-of-a-persistent-php-socket http://devzone.zend.com/303/extension-writing-part-i-introduction-to-php-and-zend/#Heading3 http://stackoverflow.com/questions/242316/how-to-keep-a-php-stream-socket-alive http://php.net/manual/en/install.fpm.configuration.php https://www.google.com/search?q=recv%28%29+failed+%28104:+Connection+reset+by+peer%29+while+reading+response+header+from+upstream+%22502%22&ei=mC1XUrm7F4WQyAHbv4H4AQ&start=10&sa=N&biw=1920&bih=953&dpr=1

    Read the article

  • overriding new ubuntu installation

    - by tkoomzaaskz
    I've got a ubuntu 11.10 which has lost its support in May 2013, now I'd like to reintall up to the most up-to-date LTS, which is 12.04. My question is regarding my current partitions and doing backups. Is there a safe way to backup my data on some local partitions instead of copying files into DVDs/external drives (this is very uncormortable in my situation). Following are system commands shoing my disk: $ lsblk NAME MAJ:MIN RM SIZE RO MOUNTPOINT sda 8:0 0 232,9G 0 +-sda1 8:1 0 48,8G 0 +-sda2 8:2 0 63G 0 +-sda3 8:3 0 1K 0 +-sda4 8:4 0 53,7G 0 / +-sda5 8:5 0 18,6G 0 +-sda6 8:6 0 25,5G 0 +-sda7 8:7 0 23,3G 0 [SWAP] sr0 11:0 1 1024M 0 and $ sudo fdisk -l [sudo] password for xyz: Disk /dev/sda: 250.1 GB, 250059350016 bytes glowic: 255, sektorów/sciezke: 63, cylindrów: 30401, w sumie sektorów: 488397168 Jednostka = sektorów, czyli 1 * 512 = 512 bajtów Rozmiar sektora (logiczny/fizyczny) w bajtach: 512 / 512 Rozmiar we/wy (minimalny/optymalny) w bajtach: 512 / 512 Identyfikator dysku: 0xc3ffc3ff Device Boot Beginning End Blocks ID System /dev/sda1 * 2048 102402047 51200000 7 HPFS/NTFS/exFAT /dev/sda2 215044096 347080703 66018304 7 HPFS/NTFS/exFAT /dev/sda3 347082750 488392064 70654657+ 5 Extended /dev/sda4 102402048 215042047 56320000 83 Linux /dev/sda5 395905923 434975939 19535008+ 83 Linux /dev/sda6 434976003 488392064 26708031 83 Linux /dev/sda7 347082752 395905023 24411136 82 Linux swap / Solaris In the beginning I had Windows Vista pre-installed with the machine when it was bought (damn!) and I installed linux (the one I have now). The windows-program in master boot record has been overriden by grub and now I can boot with both Windows and Linux. This is list of mounted devices: $ mount /dev/sda4 on / type ext4 (rw,errors=remount-ro,commit=0) proc on /proc type proc (rw,noexec,nosuid,nodev) sysfs on /sys type sysfs (rw,noexec,nosuid,nodev) fusectl on /sys/fs/fuse/connections type fusectl (rw) none on /sys/kernel/debug type debugfs (rw) none on /sys/kernel/security type securityfs (rw) udev on /dev type devtmpfs (rw,mode=0755) devpts on /dev/pts type devpts (rw,noexec,nosuid,gid=5,mode=0620) tmpfs on /run type tmpfs (rw,noexec,nosuid,size=10%,mode=0755) none on /run/lock type tmpfs (rw,noexec,nosuid,nodev,size=5242880) none on /run/shm type tmpfs (rw,nosuid,nodev) binfmt_misc on /proc/sys/fs/binfmt_misc type binfmt_misc (rw,noexec,nosuid,nodev) gvfs-fuse-daemon on /home/tomasz/.gvfs type fuse.gvfs-fuse-daemon (rw,nosuid,nodev,user=tomasz) It's strange (I don't remember such thing) that my current linux uses only one partition (/dev/sda4). But, anyway, it seems like that. My final question is: am I able to use one of the existing linux partitions for a backup and install ubuntu 12.04 without removing neither windows nor ubuntu 11.04? I mean - will grub automatically accept both old windows vista and 2 linuxes (old 11.10 and "new" 12.04)? Is there any hidden operation done while installation that could harm my custom-backup-partition while installing? my fstab file: proc /proc proc nodev,noexec,nosuid 0 0 # / was on /dev/sda4 during installation UUID=d44e89f5-9da2-48eb-83b3-887652ec95d2 / ext4 errors=remount-ro 0 1 # swap was on /dev/sda7 during installation UUID=bbe50535-ba57-434a-9272-211d859f0e00 none swap sw 0 0 sda5 and sda6 are trash partitions created during unsuccessful linux installation (this was linux installation before my current installation), I didn't delete these partitions, but I have access to them (and I can use them as backup partitions). edit: second question is: why does lsblk show /dev/sda having 232,9G while fdisk shows that it has 250.1GB? Where does the difference come from?

    Read the article

  • Cannot create zpool, how to get rid of intel raid volume?

    - by nagylzs
    This is a FreeBSD 9.1 amd64 computer. It has 5 disks installed. The ada0 and ada1 disks are used with a hw raid to provide the root filesystem: root@gw:/home/gandalf # ls /dev | grep ada ada0 ada1 ada2 ada3 ada4 root@gw:/home/gandalf # zpool status pool: zroot state: ONLINE scan: none requested config: NAME STATE READ WRITE CKSUM zroot ONLINE 0 0 0 raid/r0s1a ONLINE 0 0 0 errors: No known data errors I want to create a raidz pool for the remaining disks: root@gw:/home/gandalf # zpool create -f data raidz1 ada2 ada3 ada4 cannot create 'data': one or more devices is currently unavailable root@gw:/home/gandalf # dmesg | grep ada2 ada2 at ata4 bus 0 scbus6 target 0 lun 0 ada2: <WDC WD20EARS-00MVWB0 51.0AB51> ATA-8 SATA 2.x device ada2: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada2: 1907729MB (3907029168 512 byte sectors: 16H 63S/T 16383C) ada2: Previously was known as ad16 root@gw:/home/gandalf # dmesg | grep ada3 ada3 at ata5 bus 0 scbus7 target 0 lun 0 ada3: <SAMSUNG HD103UJ 1AA01118> ATA-7 SATA 2.x device ada3: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada3: 953868MB (1953523055 512 byte sectors: 16H 63S/T 16383C) ada3: Previously was known as ad18 GEOM_RAID: Intel-fb8732fa: Disk ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Subdisk Volume0:0-ada3 state changed from NONE to ACTIVE. root@gw:/home/gandalf # dmesg | grep ada4 ada4 at ata6 bus 0 scbus8 target 0 lun 0 ada4: <TOSHIBA DT01ACA100 MS2OA750> ATA-8 SATA 3.x device ada4: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada4: 953869MB (1953525168 512 byte sectors: 16H 63S/T 16383C) ada4: Previously was known as ad20 root@gw:/home/gandalf # dmesg | grep GEOM_RAID Aha, so ada3 is already part of another raid volume? Let's see: root@gw:/home/gandalf # dmesg | grep GEOM_RAID GEOM_RAID: SiI-130628113902: Array SiI-130628113902 created. GEOM_RAID: SiI-130628113902: Disk ada0 state changed from NONE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 state changed from NONE to STALE. GEOM_RAID: SiI-130628113902: Disk ada1 state changed from NONE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:0-ada1 state changed from NONE to STALE. GEOM_RAID: SiI-130628113902: Array started. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:0-ada1 state changed from STALE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 state changed from STALE to RESYNC. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 rebuild start at 0. GEOM_RAID: SiI-130628113902: Volume SiI Raid1 Set state changed from STARTING to SUBOPTIMAL. GEOM_RAID: SiI-130628113902: Provider raid/r0 for volume SiI Raid1 Set created. GEOM_RAID: Intel-fb8732fa: Array Intel-fb8732fa created. GEOM_RAID: Intel-fb8732fa: Force array start due to timeout. GEOM_RAID: Intel-fb8732fa: Disk ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Subdisk Volume0:0-ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Array started. GEOM_RAID: Intel-fb8732fa: Volume Volume0 state changed from STARTING to DEGRADED. GEOM_RAID: Intel-fb8732fa: Provider raid/r1 for volume Volume0 created. root@gw:/home/gandalf # Yes, indeed. I want to get rid of raid/r1 completely. However, the controller was already set to "IDE" mode in the BIOS. So why it is creating a raid volume??? I have also tried overwritting the first 16k data of ada3 and reboot the computer, but it did not help. How can I delete /dev/raid/r1 ? root@gw:/home/gandalf # graid status Name Status Components raid/r0 SUBOPTIMAL ada0 (ACTIVE (RESYNC 4%)) ada1 (ACTIVE (ACTIVE)) raid/r1 DEGRADED ada3 (ACTIVE (ACTIVE)) root@gw:/home/gandalf # graid delete raid/r1 graid: Array 'raid/r1' not found. root@gw:/home/gandalf # graid delete /dev/raid/r1 graid: Array '/dev/raid/r1' not found. root@gw:/home/gandalf # Thanks

    Read the article

  • Bridged virtual interface is not available or visible to ifconfig.

    - by Omniwombat
    Hello all. I'm running Ubuntu 9.04, kernel 2.6.28-18, and vmware-server 2.0.1. I'm attempting to setup a virtual linux machine to use a bridged interface rather than NAT or host-only. Both NAT and host-only work just fine. When running vmware-config.pl, I set /dev/vmnet0 to bridge eth0, /dev/vmnet1 to host-only, and /dev/vmnet8 to NAT. When I run ifconfig -a I see the physical interface (eth0), vmnet1 and vmnet8 both of which are up and have IP addresses assigned to them. I also see other various interfaces that are not relevant here. In the web console, when I ask that the guest machine's network card be bridged, it states that a bridged setup is "Not available" and shows the disabled device icon. Inside the guest machine, I do have an eth0 interface which I can set to anything I like, however it can't see my external network, or the host. I do see errors in my vmware/hostd.log which state: "The network bridge on device vmnet0 is not running. The virtual machine will not be able to communicate with the host or with other machines on your network" which confirms the problem. vmnet-bridge is running, and I see the following in my process table: /usr/bin/vmnet-bridge -d /var/run/vmnet-bridge-0.pid -n 0 -i eth0 I confirm that the /var/run/vmnet-bridge-0.pid file is there and that it points to the correct process. I saw this question relating to Ubuntu 9.04 and bridged interfaces, in which the poster determined that the vsock library was not getting built due to a flaw in the vmware-config.pl script. I applied the patch, reran the script, and confirm that vsock.ko and vsock.o are in my /lib directory structure. vsock does show up in an lsmod. My /etc/vmware directory has /vmnet1 and /vmnet8 subdirectories. They contain configuration utilities for running DHCP and nat type services as expected. There is no vmnet0 subdirectory. My /etc/vmware/netmap.conf file DOES show entries for vmnet0; both the name and the device as I configured it from the script. My /dev directory contains devices vmnet0 through vmnet9. They have major device number 119, and minor device numbers 0 through 9. /proc/net/dev shows statistics for vmnet1 and vmnet8, but not vmnet0. I have a /proc/vmnet directory, but it's empty. When I start or stop the vmware service with /etc/init.d/vmware start, I see the following: Starting VMware services: Virtual machine monitor done Virtual machine communication interface done VM communication interface socket family: done Virtual ethernet done Bridged networking on /dev/vmnet0 done Host-only networking on /dev/vmnet1 (background) done DHCP server on /dev/vmnet1 done Host-only networking on /dev/vmnet8 (background) done DHCP server on /dev/vmnet8 done NAT service on /dev/vmnet8 done VMware Server Authentication Daemon (background) done Shared Memory Available done Starting VMware management services: VMware Server Host Agent (background) done VMware Virtual Infrastructure Web Access Starting VMware autostart virtual machines: Virtual machines done Nothing appears to be wrong there. What n00b thing am I doing such that vmnet0 and only vmnet0 does not show up in the interface list?

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • Oracle Virtual Server OEL vm fails to start - kernel panic on cpu identify

    - by Towndrunk
    I am in the process of following a guide to setup various oracle vm templates, so far I have installed OVS 2. 2 and got the OVM Manager working, imported the template for OEL5U5 and created a vm from it.. the problem comes when starting that vm. The log in the OVMM console shows the following; Update VM Status - Running Configure CPU Cap Set CPU Cap: failed:<Exception: failed:<Exception: ['xm', 'sched-credit', '-d', '32_EM11g_OVM', '-c', '0'] => Error: Domain '32_EM11g_OVM' does not exist. StackTrace: File "/opt/ovs-agent-2.3/OVSXXenVMConfig.py", line 2531, in xen_set_cpu_cap run_cmd(args=['xm', File "/opt/ovs-agent-2.3/OVSCommons.py", line 92, in run_cmd raise Exception('%s => %s' % (args, err)) The xend.log shows; [2012-11-12 16:42:01 7581] DEBUG (DevController:139) Waiting for devices vtpm [2012-11-12 16:42:01 7581] INFO (XendDomain:1180) Domain 32_EM11g_OVM (3) unpaused. [2012-11-12 16:42:03 7581] WARNING (XendDomainInfo:1907) Domain has crashed: name=32_EM11g_OVM id=3. [2012-11-12 16:42:03 7581] ERROR (XendDomainInfo:2041) VM 32_EM11g_OVM restarting too fast (Elapsed time: 11.377262 seconds). Refusing to restart to avoid loops .> [2012-11-12 16:42:03 7581] DEBUG (XendDomainInfo:2757) XendDomainInfo.destroy: domid=3 [2012-11-12 16:42:12 7581] DEBUG (XendDomainInfo:2230) Destroying device model [2012-11-12 16:42:12 7581] INFO (image:553) 32_EM11g_OVM device model terminated I have set_on_crash="preserve" in the vm.cfg and have then run xm create -c to get the console screen while booting and this is the log of what happens.. Started domain 32_EM11g_OVM (id=4) Bootdata ok (command line is ro root=LABEL=/ ) Linux version 2.6.18-194.0.0.0.3.el5xen ([email protected]) (gcc version 4.1.2 20080704 (Red Hat 4.1.2-48)) #1 SMP Mon Mar 29 18:27:00 EDT 2010 BIOS-provided physical RAM map: Xen: 0000000000000000 - 0000000180800000 (usable)> No mptable found. Built 1 zonelists. Total pages: 1574912 Kernel command line: ro root=LABEL=/ Initializing CPU#0 PID hash table entries: 4096 (order: 12, 32768 bytes) Xen reported: 1600.008 MHz processor. Console: colour dummy device 80x25 Dentry cache hash table entries: 1048576 (order: 11, 8388608 bytes) Inode-cache hash table entries: 524288 (order: 10, 4194304 bytes) Software IO TLB disabled Memory: 6155256k/6299648k available (2514k kernel code, 135548k reserved, 1394k data, 184k init) Calibrating delay using timer specific routine.. 4006.42 BogoMIPS (lpj=8012858) Security Framework v1.0.0 initialized SELinux: Initializing. selinux_register_security: Registering secondary module capability Capability LSM initialized as secondary Mount-cache hash table entries: 256 CPU: L1 I Cache: 64K (64 bytes/line), D cache 16K (64 bytes/line) CPU: L2 Cache: 2048K (64 bytes/line) general protection fault: 0000 [1] SMP last sysfs file: CPU 0 Modules linked in: Pid: 0, comm: swapper Not tainted 2.6.18-194.0.0.0.3.el5xen #1 RIP: e030:[ffffffff80271280] [ffffffff80271280] identify_cpu+0x210/0x494 RSP: e02b:ffffffff80643f70 EFLAGS: 00010212 RAX: 0040401000810008 RBX: 0000000000000000 RCX: 00000000c001001f RDX: 0000000000404010 RSI: 0000000000000001 RDI: 0000000000000005 RBP: ffffffff8063e980 R08: 0000000000000025 R09: ffff8800019d1000 R10: 0000000000000026 R11: ffff88000102c400 R12: 0000000000000000 R13: 0000000000000000 R14: 0000000000000000 R15: 0000000000000000 FS: 0000000000000000(0000) GS:ffffffff805d2000(0000) knlGS:0000000000000000 CS: e033 DS: 0000 ES: 0000 Process swapper (pid: 0, threadinfo ffffffff80642000, task ffffffff804f4b80) Stack: 0000000000000000 ffffffff802d09bb ffffffff804f4b80 0000000000000000 0000000021100800 0000000000000000 0000000000000000 ffffffff8064cb00 0000000000000000 0000000000000000 Call Trace: [ffffffff802d09bb] kmem_cache_zalloc+0x62/0x80 [ffffffff8064cb00] start_kernel+0x210/0x224 [ffffffff8064c1e5] _sinittext+0x1e5/0x1eb Code: 0f 30 b8 73 00 00 00 f0 0f ab 45 08 e9 f0 00 00 00 48 89 ef RIP [ffffffff80271280] identify_cpu+0x210/0x494 RSP ffffffff80643f70 0 Kernel panic - not syncing: Fatal exception clear as mud to me. are there any other logs that will help me? I have now deployed another vm from the same template and used the default vm settings rather than adding more memory etc - I get exactly the same error.

    Read the article

  • e2fsck / resize2fs problems

    - by BlakBat
    I've got 6 drives (each 1.5T, all same model and firmware revision) that are part of a RAID5 array. The RAID5 makes a LVM volume group and a logical group. The latter contains only one ext3 partition. I've recently ran: e2fsck -f /dev/vg03/lv01 && resize2fs -M /dev/vg03/lv01 which exited without an error. Now when I try to mount /dev/vg03/lv01 I get: EXT3-fs error (device dm-0): ext3_check_descriptors: Block bitmap for group 30533 not in group (block 1000532368)! EXT3-fs: group descriptors corrupted! How do I get out of this predicament? This is all the info I can currently give you: fdisk -l /dev/sd[cdefgh] shows (correctly) that they are "Linux raid autodetect" but fdisk now shows: fdisk -l /dev/md0 Disk /dev/md0: 7501.5 GB, 7501495664640 bytes ... Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table (instead of a LVM type partition) fdisk -l /dev/vg03/lv01 Disk /dev/vg03/lv01: 7501.5 GB, 7501491732480 bytes ... Disk identifier: 0x00000000 Disk /dev/vg03/lv01 doesn't contain a valid partition table (instead of a ext3 type partition) I've tried: e2fsck -fy /dev/vg03/lv01 e2fsck 1.41.12 (17-May-2010) e2fsck: Group descriptors look bad... trying backup blocks... Block bitmap for group 30533 is not in group. (block 1000532368) Relocate? yes Inode bitmap for group 30533 is not in group. (block 1000532369) Relocate? yes Pass 1: Checking inodes, blocks, and sizes Relocating group 30533's block bitmap to 1000524246... Error allocating 1 contiguous block(s) in block group 30533 for inode bitmap: Could not allocate block in ext2 filesystem e2fsck: aborted Extra information I can give you: cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active (auto-read-only) raid5 sdg1[0] sdh1[5] sdf1[4] sde1[3] sdc1[2] sdd1[1] 7325679360 blocks level 5, 128k chunk, algorithm 2 [6/6] [UUUUUU] bitmap: 1/175 pages [4KB], 4096KB chunk unused devices: Lastly, all smartctl tests (short and extendend) showed no errors on any of the disks. Should I try to resize2fs to grow /dev/vg03/lv01 and redo a e2fsck ? Should I cfdisk /dev/md0 and /dev/vg03/lv01 back to their real types? Thanks in advance for all and any help. 2011-09-20 UPDATE I issued the following commands and was able to remount the partition, but by viewing the size (df) of before and after, it seems that 1Tb of data have gone missing. By checking the MD5SUMS (from an old backup) of some files with the "same" files from the remounted partition, some errors have been detected. Commands issued to remount the partition were: dumpe2fs /dev/vg03/lv01 Block count: 1000491435<br /> Block size: 4096<br /> tune2fs -O ^has_journal /dev/vg03/lv01 resize2fs -p /dev/vg03/lv01 dumpe2fs /dev/vg03/lv01 Block count: 1831418880<br /> Block size: 4096<br /> mount -o ro,noatime /dev/vg03/lv01 /mnt/raid OK... but files have been damaged / gone missing.

    Read the article

  • Forwarding rsyslog to syslog-ng, with FQDN and facility separation

    - by Joshua Miller
    I'm attempting to configure my rsyslog clients to forward messages to my syslog-ng log repository systems. Forwarding messages works "out of the box", but my clients are logging short names, not FQDNs. As a result the messages on the syslog repo use short names as well, which is a problem because one can't determine which system the message originated from easily. My clients get their names through DHCP / DNS. I've tried a number of solutions trying to get this working, but without success. I'm using rsyslog 4.6.2 and syslog-ng 3.2.5. I've tried setting $PreserveFQDN on as the first directive in /etc/rsyslog.conf (and restarting rsyslog of course). It seems to have no effect. hostname --fqdn on the client returns the proper FQDN, so the problem isn't whether the system can actually figure out its own FQDN. $LocalHostName <fqdn> looked promising, but this directive isn't available in my version of rsyslog (Available since 4.7.4+, 5.7.3+, 6.1.3+). Upgrading isn't an option at the moment. Configuring the syslog-ng server to populate names based on reverse lookups via DNS isn't an option. There are complexities with reverse DNS and the public cloud. Specifying for the forwarder to use a custom template seems like a viable option at first glance. I can specify the following, which causes local logging to begin using the FQDN on the syslog-ng repo. $template MyTemplate, "%timestamp% <FQDN> %syslogtag%%msg%" $ActionForwardDefaultTemplate MyTemplate However, when I put this in place syslog-ng seems to be unable to categorize messages by facility or priority. Messages come in as FQDN, but everything is put in to user.log. When I don't use the custom template, messages are properly categorized under facility and priority, but with the short name. So, in summary, if I manually trick rsyslog into including the FQDN, priority and facility becomes lost details to syslog-ng. How can I get rsyslog to do FQDN logging which works properly going to a syslog-ng repository? rsyslog client config: $ModLoad imuxsock.so # provides support for local system logging (e.g. via logger command) $ModLoad imklog.so # provides kernel logging support (previously done by rklogd) $ActionFileDefaultTemplate RSYSLOG_TraditionalFileFormat *.info;mail.none;authpriv.none;cron.none /var/log/messages authpriv.* /var/log/secure mail.* -/var/log/maillog cron.* /var/log/cron *.emerg * uucp,news.crit /var/log/spooler local7.* /var/log/boot.log $WorkDirectory /var/spool/rsyslog # where to place spool files $ActionQueueFileName fwdRule1 # unique name prefix for spool files $ActionQueueMaxDiskSpace 1g # 1gb space limit (use as much as possible) $ActionQueueSaveOnShutdown on # save messages to disk on shutdown $ActionQueueType LinkedList # run asynchronously $ActionResumeRetryCount -1 # infinite retries if host is down *.* @syslog-ng1.example.com *.* @syslog-ng2.example.com syslog-ng configuration (abridged for brevity): options { flush_lines (0); time_reopen (10); log_fifo_size (1000); long_hostnames (off); use_dns (no); use_fqdn (yes); create_dirs (no); keep_hostname (yes); }; source src { unix-stream("/dev/log"); internal(); udp(ip(0.0.0.0) port(514)); }; destination per_host_destination { file( "/var/log/syslog-ng/devices/$HOST/$FACILITY.log" owner("root") group("root") perm(0644) dir_owner(root) dir_group(root) dir_perm(0775) create_dirs(yes)); }; log { source(src); destination(per_facility_destination); };

    Read the article

  • Clarification On Write-Caching Policy, Its Underlying Options And How It Applies To Hard Drives And Solid-State Drives

    - by Boris_yo
    In last week after doing more research on subject matter, I have been wondering about what I have been neglecting all those years to understand write-caching policy, always leaving it on default setting. Write-caching policy improves writing performance and consists of write-back caching and write-cache buffer flushing. This is how I understand all the above, but correct me if I erred somewhere: Write-through cache / Write-through caching itself is not a part of write caching policy per se and it's when data is written to both cache and storage device so if Windows will need that data later again, it is retrieved from cache and not from storage device which means only improved read performance as there is no need for waiting for storage device to read required data again. Since data is still written to storage device, write performance isn't improved and represents no risk of data loss or corruption in case of power failure or system crash while only data in cache gets lost. This option seems to be enabled by default and is recommended for removable devices with no need to use function of "Safely Remove Hardware" on user's part. Write-back caching is similar to above but without writing data to storage device, periodically releasing data from cache and writing to storage device when it is idle. In my opinion this option improves both read and write performance but represents risk if power failure or system crash occurs with the outcome of not only losing data eventually to be written to storage device, but causing file inconsistencies or corrupted file system. Write-back caching cannot be enabled together with write-through caching and it is not recommended to be enabled if no backup power supply is availabe. Write-cache buffer flushing I reckon is similar to write-back caching but enables immediate release and writing of data from cache to storage device right before power outage occurs but I don't know if it applies also to occasional system crash. This option seem to be complementary to write-back cache reducing or potentially eliminating risk of data loss or corruption of file system. I have questions about relevance of last 2 options to today's modern SSDs in order to get best performance and with less wear on SSDs: I know that traditional hard drives come with onboard cache (I wonder what type of cache that is), but do SSDs also come with cache? Assuming they do, is this cache faster than their NAND flash and system RAM and worth taking the risk of utilizing it by enabling write-back cache? I read somewhere that generally storage device's cache is faster than RAM, but I want to be sure. Additionally I read that write-caching should be enabled since current data that is to be written later to NAND flash is kept for a while in cache and provided there is data that gets modified a lot before finally being written, holding of this data and its periodic release reduces its write times to SSD thereby reducing its wearing. Now regarding to write-cache buffer flushing, I heard that SSD controllers are so fast by themselves that enabling this option is not required, because they manage flushing. However, once again, I don't know if SSDs have their own onboard cache and whether or not it is faster than their NAND flash and system RAM because if it is, keeping this option enabled would make sense. Recently I have posted question about issue with my Intel 330 SSD 120GB which was main reason to do deeper research having suspicion of write-caching policy being the culprit of SSD's freezing issue assuming data being released is what causes freezes. Currently I have write-cache enabled and write-cache buffer flushing disabled because I believe SSD controller's management of write-cache flushing and Windows write-cache buffer flushing are conflicting with each other: Since I want to troubleshoot in small steps to finally determine the source of issue, I have decided to start with write-caching policy and the move to drivers, switching to AHCI later on and finally disabling DIPM (device initiated power management) through registry modification thanks to @TomWijsman

    Read the article

  • Do hard drive enclosures fail/is it the HDD or enclosure?

    - by x0a
    I'm having a whole host of problems with an external hard drive that was working just fine a couple of hours ago. I've had this problem before once, and that was about 3 months ago, here's what I documented: So a couple of hours ago I turned off all my computers and shut off the power to all my devices in my room, then went and turned the power off at the main switch so I could change an outlet. A couple hours later, after I've already slowly turned everything back on, I go to my xbox to try and watch a movie and it can't seem to list any of the movies I've got. So I go to my desktop to find that my external hard drive isn't there.. even though it's on and connected. It's also stationary and hidden behind something so there's not a whole lot of tampering/physical wear to that external. I plug it into my laptop to try and see what's going on. It starts making this endless loud screeching noise. None of that clicking that's usually associated with hd damage. It's not listed in my computers, and it shows up in Disk Management as "uninitialized" asking me to choose between two different partition types. After carefully disconnecting it and connecting it back, it asks me to format it, which I cancel. I start googling about my issue, starting to accept the situation, torn as hell and helpless and just about ready to toss the thing. Suddenly the screeching stops, after almost 45 minutes of it going, and Disk Management lists the drive as "Online" and "Healthy". Explorer pops up with all my files! I'm still being really careful with it and weary and treating it as though it's in fragile shape. I've downloaded some S.M.A.R.T. software to read the values and everything is listed as "OK" . No reallocated sectors, no read errors, no seek errors. I also ran a quick self-test, which completed without error. Everything seems fine. It looks to be a perfectly healthy external hard drive. So what the hell was that about? Was it doing some sort of maintenance or self-test? How am I supposed to tell the difference? I would've undoubtedly killed the drive for sure if had it gone on a bit longer. I've got the same problem now, with one exception: it doesn't magically reappear after the screeching stops. Occasionally I manage to get some S.M.A.R.T. diagnostics information, which basically reads everything as fine. The only problem is that my HD isn't initializing (so I can't access anything in it). I'm able to successfully run a quick smart test but not an extended one (I've only tried it once but got conflicting indications as to whether it was actually making any progress or not (was stuck on Random read test). So, final question (if all else fails): Could the hard drive enclosure be failing rather than the HDD? Is this a likely possibility at all? How would I know?

    Read the article

  • Just a few questions about Hyper-V virtual machines and clustering

    - by René Kåbis
    I have been using Microsoft’s Hyper-V technology for a little while now, but I am just now dipping my toe into clustering. In particular, I am trying to implement a fault-tolerant SQL DB. This involves setting up two VMs, clustering them via Failover Cluster, and then installing SQL Server in some fashion. I have two physical machines - one high-end and rather beefy “heavy lifter” to contain the majority of the VMs, and another “backup” (a repurposed desktop) to hold the essential “secondary” (or failover) AD-DC, SQL and FS VMs. The main reason why I find the failover cluster at the VM level so attractive is that it presents a single IP and DNS entry to the network as a whole - if one machine (physical or virtual) goes down, you might loose some ping and the connections get reset, but the network applications (Microsoft RMS connection to backend SQL) can still connect to a viable DB without having to mess around with the settings at all. My first question is in terms of SQL Server itself. If I have a cluster between two VMs, does it make more sense to install the SQL Server in Failover Cluster configuration or should I simply install it in a stand-alone config and mirror the DBs? For example, this post suggests just mirroring the DBs, but do I just mirror standalone DBs on standalone VMs, or can I get the network and failover benefits of clustered VMs while still utilizing (on each clustered VM) standalone DBs that have been mirrored between each other? As well, I have come across a lot of documentation about SQL clustering, but most assume a number (#2) of physical machines to hold not only the actual SQL VMs but also the Quorum and Witness stores. I will not be able to muster more than two physical machines. As such, I will have to be satisfied with a VM cluster that does not exceed two VMs (one for each physical machine). Another issue involves MSDTC - the Distributed Transaction Coordinator. When attempting to install the SQL Failover Cluster (I never completed it for this reason) it threw a hissy fit because MSDTC had not been clustered. Search as I might, I have not yet found a way to do so under Windows Server 2012 R2. I have found plenty of docs for Windows 2008 and 2008 R2, but these instructions don’t align with 2012 R2 (at least, not in a way that allows me to successfully cluster MSDTC). Plus, some of the instructions that I have found for SQL Server Failover Cluster installation suggest that a third “network device” - shared network storage (a SAN) - is required for the DB itself (and other functionality). I do not have this, and won’t be getting this. Most of my storage exists on the “heavy lifter” that was designed for all of the “primary” VMs. If that physical machine goes down, so does the storage. The secondary server does have enough resources for an AD-DC Server, an SQL server and a File Server, so it will handle the “secondary” failover versions of those VMs (clustered or not). My final question involves file servers. If I cluster file servers between two VMs (one on my “heavy lifter” and another on my “backup”, how do I mirror the data between them? Clustering VMs only provides a single point of access on the network for a resource, it doesn’t exactly replicate data between the two - that is left to the services that serve up that data. I am unsure how I can ensure that file server data between two clustered file server VMs can be properly mirrored. Remember, I only have two devices to be used here - my primary machine and a backup secondary. There is no chance of me obtaining a SAN or any other type of network attached storage. What exists on the machines must act as the storage. Thanks in advance for any suggestions.

    Read the article

  • How to stop windows resizing when the monitor display channel is turned off / switched to different source

    - by Heartspeace
    Have a new 6870 ati radeon adapter with its drivers set to 1080p 60hz resolution hooked up to a 2008 47" high end Samsung HDMI based TV. However, when the tv is turned to a different hdmi input -(when I come back into windows) somehow Windows decides to resize all the open apps to a lower resolution - including some of the side docked hidden pop-outs. When it resizes those though - it just sticked the pop-outs in the middle of the screen and all the resized windows from the open applications in the top left corner - all of them stacked on top of each other and resized to the smaller resolution. The things that seem to be ok after returning are the icons on the desktop, the taskbar, and the sidebar. Anyone have any knowledge of 1) how this happens 2) why it happens 3) how to stop it from resizing the applications and some of the docked pop-outs (they are not really resized after returning - they are just stuck in the middle of the screen approximately where they would be if the right or bottom sidebar should be if the screen was resized to that lower resolution). My hypothesis is that upon losing HDMI signal - that Windows is told by something (driver, or windows itself) that the resolution to be without a signal being present (noting that HDMI signals and handshakes are two way on HDMI devices. If it loses the signal or the tv is switched to another device - then the display adapter must figure that out and tell Windows or figures it out and designs randomly to change the display size). Any and all help is most appreciated. I asked AMD/ATI - but they said they don't know why or how this is happening. I was hoping that maybe this is THE place that the super users truly go to - those that develop display adapter drivers, or that dive deeply into these areas of windows. If there is better sites or just competing sites - please advise - noting I have already written AMD/ATI. HP Response / Additions 4/7/2011 It is really nice to get your reply Shinrai. (BTW is it proper etiquette on these forums to have a discussion?) Yet 'only one issue' - I am using a single display in this case - so Windows doesn't move application windows to another desktop. Windows (or something) decides to shrink the desktop it currently has and resize all windows to the maximum size of the desktop. As such I would be glad if Windows would just keep the current size of the one desktop that is in operation. I also know that this does NOT happen on monitors connected with DVI. There I have had one and two monitors setup and it doesn't resize those screens at all when disconnecting monitors, turning them off, whatever... they stay solid - everything in place - to such an extent that if you forgot the other monitor is off - you will have troubles finding some windows without using one of the control app utilities. So if I could even get the HDMI handling by Windows (or the display driver) ( 1] which is doing this anyway the display driver or Windows - and 2] where is that other resolution size (1024x768) coming from - its not the smallest and its not the largest?) to be having like DVI - Life would be golden (for this aspect anyway). ** found others with same problem in this thread: http://hardforum.com/showthread.php?t=1507324 Thanks, HP

    Read the article

  • Where is my VMware-ws FreeNAS CIFS(ZFS) bottle-neck?

    - by maka
    Background: I'm building a quiet HTPC + NAS that is also supposed to be used for general computer usage. I'm so far generally happy with things, it was just that I was expecting a little better IO performance. I have no clue if my expectations are unreal. The NAS is there as a general purpose file storage and as a media server for XBMC and other devices. ZFS is a requirement. Question: Where is my bottle-neck, and is there anything I can do config wise, to improve my performance? I'm thinking VM-disk settings could be something but I really have no idea where to go since I'm neither experienced with FreeNAS nor VMware-WS. Tests: When I'm on the host OS and copy files (from the SSD) to the CIFS share, I get around 30 Mbytes/sec read and write. When I'm on my laptop laptop, wired to the network, I get about the same specs. The test I've done are with a 16 GB ISO, and with about 200 MB of RARs and I've tried avoiding the RAM-cache by reading different files than the ones I'm writing ( 10 GB). It feels like having less CPU cores is a lot more efficient, since the resource manager in Windows reports less CPU-usage. With 4 cores in VMware, CPU usage was 50-80%, with 1 core it was 25-60%. EDIT: HD ActiveTime was quite high on SSD so I moved the page file, disabled hibernate and enabled Win DiskCache both on SSD and RAID. This resulted in no real performance difference for one file, but if i transferred 2 files the total speed went up to 50 Mbytes/s vs ~40. The ActiveTime avg also went down a lot (to ~20%) but has now higher bursts. DiskIO is on ~ 30-35 Mbytes/s avgs, with ~100Mb bursts. Network is on 200-250Mbits/s with ~45 active TCP connections. Hardware Asus F2A85-M Pro A10-5700 16GB DDR3 1600 OCZ Vertex 2 128GB SSD 2x Generic 1tb 7200 RPM drives as RAID0 (in win7) Intel Gigabit Desktop CT Software Host OS: Win7 (SSD) VMware Worksation 9 (SSD) FreeNAS 8.3 VM (20GB VDisk on SSD) CPU: I've tried 1, 2 and 4 cores. Virtualisation engine, Preferred mode: Automatic 10,24Gb ram 50Gb SCSI VDisk on the RAID0, VDisk is formatted as ZFS and exposed through CIFS through FreeNAS. NIC Bridge, Replicate physical network state Below are two typical process print-outs while I'm transfering one file to the CIFS share. last pid: 2707; load averages: 0.60, 0.43, 0.24 up 0+00:07:05 00:34:26 32 processes: 2 running, 30 sleeping Mem: 101M Active, 53M Inact, 1620M Wired, 2188K Cache, 149M Buf, 8117M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 102 0 50164K 10364K RUN 0:25 25.98% smbd 1897 root 6 44 0 168M 74808K uwait 0:02 0.00% python last pid: 2746; load averages: 0.93, 0.60, 0.33 up 0+00:08:53 00:36:14 33 processes: 2 running, 31 sleeping Mem: 101M Active, 53M Inact, 4722M Wired, 2188K Cache, 152M Buf, 5015M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 76 0 50164K 10364K RUN 0:52 16.99% smbd 1897 root 6 44 0 168M 74816K uwait 0:02 0.00% python I'm sorry if my question isn't phrased right, I'm really bad at these kind of things, and it is the first time I post here at SU. I also appreciate any other suggestions to something, I could have missed.

    Read the article

< Previous Page | 392 393 394 395 396 397 398 399 400 401 402 403  | Next Page >