Search Results

Search found 12726 results on 510 pages for 'compatibility mode'.

Page 405/510 | < Previous Page | 401 402 403 404 405 406 407 408 409 410 411 412  | Next Page >

  • Virtualbox port forwarding with iptables

    - by jverdeyen
    I'm using a virtualmachine (virtualbox) as mailserver. The host is an Ubuntu 12.04 and the guest is an Ubuntu 10.04 system. At first I forwarded port 25 to 2550 on the host and added a port forward rule in VirtualBox from 2550 to 25 on the guest. This works for all ports needed for the mailserver. The guest has a host only connection and a NAT (with the port-forwarding). My mailserver was receiving and sending mail properly. But all connections are comming from the virtualbox internal ip, so every host connection is allowed, and that's not what I want. So.. I'm trying to skip the VirtualBox forwarding part and just forward port 25 to my host only ip of the guest system. I used these rules: iptables -F iptables -P INPUT ACCEPT iptables -P OUTPUT ACCEPT iptables -P FORWARD ACCEPT iptables -t nat -P PREROUTING ACCEPT iptables -t nat -P POSTROUTING ACCEPT iptables -A INPUT --protocol tcp --dport 25 -j ACCEPT iptables -A INPUT -i lo -j ACCEPT iptables -A INPUT -s 192.168.99.0/24 -i vboxnet0 -j ACCEPT echo 1 > /proc/sys/net/ipv4/ip_forward iptables -t nat -A PREROUTING -p tcp -i eth0 -d xxx.host.ip.xxx --dport 25 -j DNAT --to 192.168.99.105:25 iptables -A FORWARD -s 192.168.99.0/24 -i vboxnet0 -p tcp --dport 25 -j ACCEPT iptables -t nat -A POSTROUTING -s 192.168.99.0 -o eth0 -j MASQUERADE iptables -L -n But after these changes I still can't connect with a simple telnet. (Which was possible with my first solution). The guest machine doesn't have any firewall. I only have one network interface on the host (eth0) and a host interface (vboxnet0). Any suggestions? Or should I go back to my old solution (which I don't really like). Edit: bridge mode isn't an option, I have only on IP available for the moment. Thanks!

    Read the article

  • Vista Screen resolution Changes when Switching Users

    - by Benjol
    I regularly have a problem when switching between users in Vista - the screen resolution drops down to 800x600. If I try to set the resolution back to the maximum, it says nothing, but just keeps it at 800x600. I can set it back to an intermediate value. Otherwise I have to either restart the PC, or sometimes if I log off one of the users, I can then set the resolution back to max. Might it also have something to do with using sleep mode instead of performing regular shutdowns? I thought it might be related to the desktop background image taking up too much space, but even with plain colours, the problem still occurs. There is an enormous thread on this here, but not really any answers. From what I can gather from that thread, it isn't related to any particular applications, nor limited to a particular make of graphics card or monitor, so I don't think that including hardware details is useful. This is a very annoying problem, as it screws up my desktop and screen layout every single time. Has anyone here experienced this problem or found a solution? I've noticed that Windows Update has tried to install nVidia updates and apparently they've failed on several occasions. Not sure if that is of any relevance or not. UPDATE The last post on the thread: FWIW - I had this problem for about 2 years and wrote a number of posts in this thread in the past. It survived OS reinstallation, change of practically all of my hardware piece by piece (mobo, cpu, monitor, graphics card, memory, power supply...) I used to be affected by this annoying problem at least once every 24-48 hours. About 1.5 months ago I wiped out my 32 bit vista ultimate installation and installed Windows7 ultimate 64 bit from scratch and never saw this problem again. GOOD RIDDANCE. Vista was a pathetic piece of __ that felt like a flashback to the old [horrible] NT4/Windows95 days. I was seriously considering switching over to Apple/Mac OSX if this problem persisted.

    Read the article

  • Recommend a free temperature-monitoring utility for cores + video card, on Vista?

    - by smci
    Looking for your recommendations for a free temperature-monitoring utility, for my PC (Core 2) and graphics card for Vista. (Question reposted with the hyperlinks now I have 10 reputation). I don't want all the geeky details, I don't overclock, I don't see the need to mess with my fan speeds or motherboard settings, I just want something fairly basic to help with basic troubleshooting of intermittent overheats on video card and/or mobo: must run on Windows Vista (yes, don't laugh). ideally displays temperature when minimized to toolbar, and/or: automatically alerts me when temperature on either core or the video card exceeds a threshold ideally measures temperature of video card and system as well, not just the cores. HDD temperature is not necessary I think. logging is nice, graphs are also nice portability to Linux and Mac is nice Apparently Everest is the best paid option, but I'm not prepared to spend $40. I found the following free options, but no head-to-head at-a-glance comparison: CoreTemp (only does cores, not video card?) Open Hardware Monitor (nice graphs, displays when minimized to toolbar, no alerts) RealTemp (has alerts, works minimized, lightweight install) HWMonitor (no alerts, CNET: "[free version is] simple but effective") from CPUID CPUCool (not free: 21-day trialware, then $18) SpeedFan from Almico (too geeky, detail overload; CNET: "most users won't be able to make head or tail of the data this utility provides") Motherboard Monitor (CNET: not recommended, requires expert knowledge of your mobo, dangerous) Intel Thermal Analysis Tool (only does cores, not video card? has logging) Useful discussions I found: hardwarecanucks.com , superuser.com 1, 2 , forums.techarena.in (Update: I downloaded Real Temp 3.60 and it meets all my needs, the customizable alert temperature is great. Open Hardware Monitor seems to be the other one that mostly meets my needs, except no alerts; but it is portable. I tried SpeedFan but the interface is very cluttered, too much unnecessary detail (needs a Basic/Advanced mode and a revamp of the interface.) The answer to my underlying issue is nVidia Geforce LE 7500 video card which runs very hot.)

    Read the article

  • Outlook 2010 not resolving SMTP address to Display Name

    - by Ben
    I have a weird problem where a user (director, naturally) has an odd problem with the way the to field shows in his Outlook. We are using Outlook 2010 (with RPC/HTTP) and Exch 2003 at the back end. Most of his mail shows in his mailbox with the To: field as normal. (e.g. Fred Bloggs in the to field.) However, some mails come in showing in the To: field as [email protected]. (Apparently this is an issue!) For example, most show as: but a few come in as: There doesn't appear to be a pattern to this. I have tried to replicate by: Sending from any specific senders to see if it recurs (it doesn't) Typing his full name in my Outlook and sending (it resolves as normal) Sending programatically (e.g. from script) - (it still resolves OK) Forcing a "[email protected]" entry in my Outlook. It resolves as soon as I hit enter Sending in cached mode Sending disconnected Anyone got any ideas how I can either replicate the problem or fix it! I can't tell at the moment whether it is a problem at his end or the sender's. EDIT This seems to be a global issue, following some more digging. Most people seem to have a few emails in their inbox addressed to their smtp address, rather than display name.

    Read the article

  • Is execution of sync(8) still required before shutting down linux?

    - by Amos Shapira
    I still see people recommend use of "sync; sync; sync; sleep 30; halt" incantations when talking about shutting down or rebooting Linux. I've been running Linux since its inception and although this was the recommended procedure in the BSD 4.2/4.3 and SunOS 4 days, I can't recall that I had to do that for at least the last ten years, during which I probably went through shutdown/reboot of Linux maybe thousands of times. I suspect that this is an anachronism since the days that the kernel couldn't unmount and sync the root filesystem and other critical filesystems required even during single-user mode (e.g. /tmp), and therefore it was necessary to tell it explicitly to flush as much data as it can to disk. These days, without finding the relevant code in the kernel source yet (digging through http://lxr.linux.no and google), I suspect that the kernel is smart enough to cleanly unmount even the root filesystem and the filesystem is smart enough to effectively do a sync(2) before unmounting itself during a normal "shutdown"/"reboot"/"poweorff". The "sync; sync; sync" is only necessary in extreme cases where the filesystem won't unmount cleanly (e.g. physical disk failure) or the system is in a state that only forcing a direct reboot(8) will get it out of its freeze (e.g. the load is too high to let it schedule the shutdown command). I also never do the "sync" procedure before unmounting removable devices, and never hit a problem. Another example - Xen allows the DomU to be sent a "shutdown" command from the Dom0, this is considered a "clean shutdown" without anyone having to login and type the magical "sync; sync; sync" first. Am I right or was I lucky for a few thousands of system shutdowns?

    Read the article

  • Nginx proxy to IIS Connection Timeout

    - by MitMaro
    I am having an issue with random timeouts with a Nginx proxy connecting to an IIS machine. I have been watching a packet capture between the two servers and it seems that the IIS machine is receiving a SYN packet but is not responding with what I think should be an ACK response. Before the timeout occurs there seems to be a slower response from the IIS server. There is no unusual memory or processor usage on the IIS or Nginx machine. Some information on the servers and setup: Nginx Machine: Ubuntu 10.04 64bit Nginx 0.7.65 Amazon EC2 Windows Machine: Windows Server 2008 IIS 7 ASP.net Application in Integrated Mode Nginx Error: 2011/01/10 17:57:40 [error] 8297#0: *30 connect() failed (110: Connection timed out) while connecting to upstream, client: 209.***.***.***, server: secure.example.com, request: "GET /a/path/deliver.aspx HTTP/1.1", upstream: "http://***.***.***.****:****//another/path/deliver.aspx", host: "secure.example.com" WireShark Packets 6521.449528 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477422103 TSER=0 WS=7 6524.443239 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477422403 TSER=0 WS=7 6530.443241 10.***.***.*** -> 174.***.***.*** TCP 38695 > us-cli [SYN] Seq=0 Win=5840 Len=0 MSS=1460 TSV=477423003 TSER=0 WS=7

    Read the article

  • HP Laserjet 1320 drivers for Windows 7

    - by RedGrittyBrick
    Background I replaced som XP computers with Win 7 computers. We have a HP Laserjet 1320dn printer attached to the LAN. The XP computers could print to it from Word in duplex mode without any issues. Problem The Win 7 computers downloaded a full set of drivers including a "HP Laserjet 1320 PCL5" driver. However using this, Word's page footers cause extra pages to be printed with just a letter or so at a time from the footer. Some other apps have similar issues. I also have an ancient Laserjet 1200 attached to the LAN via a Jetdirect box and that works just fine. So I don't think the problem is with Word (the computers came with Word 2010 starter). What I tried I wrangled the control-panel new printer dialogue into using a "HP Laserjet 2100 PS" driver for the HP Laserjet 1320dn. Now my Word documents print as they should. However I don't have a duplex option on the print dialogue. I'd really like to be able to use duplex printing. Question Windows used to have a Universal Postscript driver that read a Postscript Printer Definition (PPD) file to make the printer's features available (tray choice, duplex etc). I can't see any way to do this in Windows 7. Is there a way? Is there any other way I can get Windows 7 Home Premium 64-bit to print properly to a HP Laserjet 1320dn and have access to all it's major features? Addendum: My page in Word looks like this: +--------------------+ | aa bb cc | | | | lorem ipsum dolor | | | ... | | | pp qq rr | +--------------------+ The headers and footers were inserted using Insert - header - blank (3 column). When printed I get 1 page with aa, bb, cc, pp in correct position (no other text) 1 blank page 1 page with qq in correct position (no other text) 1 blank page 1 page with rr in correct position (no other text) 1 blank page 1 page with lorem ipsum dolor in correct position (no headers or footers) If I use a Laserjet 2100 driver I get 1 correct page.

    Read the article

  • external drive and CentOS - Reset high speed USB device number

    - by Phil
    I have 2 external drives (3TB) and both will not work with my centOS Box. Tested them in windows ( different machine ) No problems ( 2.6.32-279.9.1.el6.i686 ) dmesg reports: usb 2-2: new high speed USB device number 3 using ehci_hcd usb 2-2: New USB device found, idVendor=2109, idProduct=0700 usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=3 usb 2-2: Product: USB 3.0 SATA Bridge usb 2-2: Manufacturer: VIA Labs, Inc. usb 2-2: SerialNumber: 0000000000006121 usb 2-2: configuration #1 chosen from 1 choice scsi6 : SCSI emulation for USB Mass Storage devices usb-storage: device found at 3 usb-storage: waiting for device to settle before scanning usb-storage: device scan complete scsi 6:0:0:0: Direct-Access ST3000DM 001-9YN166 CC4B PQ: 0 ANSI: 2 sd 6:0:0:0: Attached scsi generic sg3 type 0 sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] 5860533165 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 6:0:0:0: [sdd] Write Protect is off sd 6:0:0:0: [sdd] Mode Sense: 00 06 00 00 sd 6:0:0:0: [sdd] Assuming drive cache: write through sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] Assuming drive cache: write through sdd: sdd1 sd 6:0:0:0: [sdd] Very big device. Trying to use READ CAPACITY(16). sd 6:0:0:0: [sdd] Assuming drive cache: write through sd 6:0:0:0: [sdd] Attached SCSI disk Tyring to use cfdisk / fdisk / gdisk or even fdisk -l results in the program hanging and dmesg reports: usb 2-2: reset high speed USB device number 3 using ehci_hcd usb 2-2: reset high speed USB device number 3 using ehci_hcd usb 2-2: reset high speed USB device number 3 using ehci_hcd I have the same 2 drives physically installed in the computer via SATA Any Ideas?

    Read the article

  • SQL Server Instance login issue

    - by reallyJim
    I've just brought up a new installation of SQL Server 2008. I installed the default instance as well as one named instance. I'm having a problem connecting to the named instance from anywhere besides the server itself with any user besides 'sa'. I am running in mixed mode. I have a login/user that has a known username. Using that user/login, I can properly connect when directly on the server. When I attempt to login from anywhere else, I recieve a "Login failed for user ''", with Error 18456. In the log file in the server, I see a reason that doesn't seem to help: "Reason: Could not find a login matching the name provided.". However, that user/login DOES exist, as I can use it locally. There are no further details about the error. Where can I start to find something to help me with this? I've tried deleting and recreating the user, as well as just creating a new one from scratch--same result, locally fine, remotely an error. EDIT: Partially Resolved. I'm now passed the base issue--the clients were trying to connect via the default instance. I don't know why. So, once proper ports were opened in the firewall, and a static port assigned to the named instance, I can now connect--BUT ONLY if I specify the connection as Server,Port. SQLBrowser is apparently not helping/working in this case. I've verified it IS running, and done a stop/restart after my config changes, but no difference yet.

    Read the article

  • "one-off" use of http_proxy in a Chef remote_file resource

    - by user169200
    I have a use case where most of my remote_file resources and yum resources download files directly from an internal server. However, there is a need to download one or two files with remote_file that is outside our firewall and which must go through a HTTP proxy. If I set the http_proxy setting in /etc/chef/client.rb, it adversely affects the recipe's ability to download yum and other files from internal resources. Is there a way to have a remote_file resource download a remote URL through a proxy without setting the http_proxy value in /etc/chef/client.rb? In my sample code, below, I'm downloading a redmine bundle from rubyforge.org, which requires my servers to go through a corporate proxy. I came up with a ruby_block before and after the remote_file resource that sets the http_proxy and "unsets" it. I'm looking for a cleaner way to do this. ruby_block "setenv-http_proxy" do block do Chef::Config.http_proxy = node['redmine']['http_proxy'] ENV['http_proxy'] = node['redmine']['http_proxy'] ENV['HTTP_PROXY'] = node['redmine']['http_proxy'] end action node['redmine']['rubyforge_use_proxy'] ? :create : :nothing notifies :create_if_missing, "remote_file[redmine-bundle.zip]", :immediately end remote_file "redmine-bundle.zip" do path "#{Dir.tmpdir}/redmine-#{attrs['version']}-bundle.zip" source attrs['download_url'] mode "0644" action :create_if_missing notifies :decompress, "zipp[redmine-bundle.zip]", :immediately notifies :create, "ruby_block[unsetenv-http_proxy]", :immediately end ruby_block "unsetenv-http_proxy" do block do Chef::Config.http_proxy = nil ENV['http_proxy'] = nil ENV['HTTP_PROXY'] = nil end action node['redmine']['rubyforge_use_proxy'] ? :create : :nothing end

    Read the article

  • Connect to Nonencrypted Wireless Network Using Ubuntu Commands

    - by Tim
    I failed to connect to an open i.e. nonencrypted wireless network using Ubuntu command lines. Here is what I did: $ sudo /etc/init.d/NetworkManager stop * Stopping network connection manager NetworkManager [ OK ] $ sudo /sbin/ifconfig wlan0 up $ sudo iwconfig wlan0 essid "Cavalier High-Speed 866-4-CAVTEL" $ sudo dhclient wlan0 There is already a pid file /var/run/dhclient.pid with pid 10812 killed old client process, removed PID file Internet Systems Consortium DHCP Client V3.1.1 Copyright 2004-2008 Internet Systems Consortium. All rights reserved. For info, please visit http://www.isc.org/sw/dhcp/ wmaster0: unknown hardware address type 801 wmaster0: unknown hardware address type 801 Listening on LPF/wlan0/00:0e:9b:cd:4e:18 Sending on LPF/wlan0/00:0e:9b:cd:4e:18 Sending on Socket/fallback DHCPREQUEST of 192.168.1.67 on wlan0 to 255.255.255.255 port 67 DHCPREQUEST of 192.168.1.67 on wlan0 to 255.255.255.255 port 67 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 7 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 7 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 8 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 12 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 21 DHCPDISCOVER on wlan0 to 255.255.255.255 port 67 interval 6 No DHCPOFFERS received. Trying recorded lease 192.168.1.67 PING 192.168.1.1 (192.168.1.1) 56(84) bytes of data. --- 192.168.1.1 ping statistics --- 1 packets transmitted, 0 received, +1 errors, 100% packet loss, time 0ms Trying recorded lease 192.168.1.45 PING 192.168.1.1 (192.168.1.1) 56(84) bytes of data. --- 192.168.1.1 ping statistics --- 1 packets transmitted, 0 received, +1 errors, 100% packet loss, time 0ms No working leases in persistent database - sleeping. $ sudo /sbin/iwconfig wlan0 wlan0 IEEE 802.11bg Mode:Managed Frequency:2.422 GHz Access Point: Not-Associated Tx-Power=27 dBm Retry min limit:7 RTS thr:off Fragment thr=2352 B Encryption key:off Power Management:off Link Quality:0 Signal level:0 Noise level:0 Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 I was wondering what the problem is and how I can do it right? Thanks and regards!

    Read the article

  • Should I use "Raid 5 + spare" or "Raid 6"?

    - by Trevor Boyd Smith
    What is "Raid 5 + Spare" (excerpt from User Manual, Sect 4.17.2, P.54): RAID5+Spare: RAID 5+Spare is a RAID 5 array in which one disk is used as spare to rebuild the system as soon as a disk fails (Fig. 79). At least four disks are required. If one physical disk fails, the data remains available because it is read from the parity blocks. Data from a failed disk is rebuilt onto the hot spare disk. When a failed disk is replaced, the replacement becomes the new hot spare. No data is lost in the case of a single disk failure, but if a second disk fails before the system can rebuild data to the hot spare, all data in the array will be lost. What is "Raid 6" (excerpt from User Manual, Sect 4.17.2, P.54): RAID6: In RAID 6, data is striped across all disks (minimum of four) and a two parity blocks for each data block (p and q in Fig. 80) is written on the same stripe. If one physical disk fails, the data from the failed disk can be rebuilt onto a replacement disk. This Raid mode can support up to two disk failures with no data loss. RAID 6 provides for faster rebuilding of data from a failed disk. Both "Raid 5 + spare" and "Raid 6" are SO similar ... I can't tell the difference. When would "Raid 5 + Spare" be optimal? And when would "Raid 6" be optimal"? The manual dumbs down the different raid with 5 star ratings. "Raid 5 + Spare" only gets 4 stars but "Raid 6" gets 5 stars. If I were to blindly trust the manual I would conclude that "Raid 6" is always better. Is "Raid 6" always better?

    Read the article

  • Windows 7 notebook turn off by itself, how to check if it is due to CPU being too hot?

    - by Jian Lin
    I have a Dell Studio 15 notebook, and it just started turning off by itself yesterday. Could it be that the CPU is too hot? I have had several notebooks before and every one of them I can put them on the bed without any problem. This Dell Studio Notebook, however, seems like have the air / fan outlet pointed outward from the bottom back of the notebook, so I suspect that the air is partially blocked when it is on the bed. Are there Win 7 tools that can monitor the CPU temperature, or will some 3rd party tool be needed? (I try to stick to official tools nowadays). Also, it is running Win 7 Ulitmate, there is actually no utility or background service from Win 7 or from Dell that detects when the temperature is too hot (or 95% near the max), pop out a message box giving a warning and say that the computer will go into sleep mode in 1 minute, but instead just turn off the computer by brute force (cutting out the power) right then and there? Update: it turned off right in front of my eyes -- it is not doing any windows update or anything. just normal use and jooooop, it turned off.

    Read the article

  • Having Trouble Ripping Some CD's

    - by James
    Hi, When I buy CD's I tend to rip them to FLAC right away. When ripping I use Foobar2000 or Exact Audio Copy and enable secure ripping which uses error correction. Recently I bought a 2 CD compilation album brand new but when I tried to rip the second CD on my laptop using Foobar2000 it struggled with the last 2 tracks and was unable to finish. EAC was also unable to get an accurate rip and reports read errors. Ripping in fast mode results in audible errors in the output track. I have tried another computer and having similar problems. I cannot see any damage to the disc and it has not been dropped or anything. The weird thing is that I had similar problems with a different album and different PC a while back. This other CD was a compilation disk so it was also right up to the CD capacity limit and again it was the last few tracks that would not rip. Dozens of other discs have ripped fine So I am wondering if the CD is simply defective, or whether it is something else. How common are defective CD's? Do some CD drives struggle with CD's of this capacity? Or Is this some kind of copy protection? I'm thinking of asking Amazon for a replacement but it would be annoying if I get the same problem again.

    Read the article

  • Windows is very slow with my new SSD

    - by Maksym H.
    I have a laptop HP probook 4520s with Core i5 M480 @ 2.67Ghz, 4Gb RAM, 640 GB HDD Radeon HD 6370m 1GB video card. It would seem like a good stack for work, right? But My HDD has crashed after everyday walking with laptop about 1 year. After buying my new SSD (Patriot memory - Torqx II 128 Gb SATA II) and installing new Windows 8 from scratch - it was amazing fast. But I had only install windows updates, and I feel that the speed become the same as my old HDD, after install other software for my work, it becomes so slow, so when I use my PC with old lower configuration and it really works better than my awesome laptop... I checked that TRIM and AHCI mode are turned on. So why's that? I asked for help in Patriot Memory support, they suggested to send them ATTO test results, done, sent. Here is the response: "Thank you very much for the attached results. Looking at the results, I can see that your SSD speed is a lot lower than it should be. Can you tell me your system specs?" Until they checked my email, I re-installed Windows 8 to Windows 7 and it was again perfect, but the story repeats it becomes slower and slower after every installing new software. Check out some screenshots.. (sorry for the screenshot with russian TaskManager, I hope you will recognize those parameters accordingly with your english or other lang TaskManager) So the main issue that something everytime loads the disc on 100% and the response time is jumping around 1000-3000 ms. Why am I asking about Windows? Because I tried to install Linux Mint (x86) and It just flies. So great performance independent on how many programs I have installed. Only Windows (any 7 or 8) has this problem. So guys, I appreciate any ideas about how to fix that and may be answers of main question - "why is it so.?" Thanks!

    Read the article

  • Weirdly high ping on direct ethernet connection?

    - by Antriel
    I bought new Lenovo IdeaCentre H430 pc and I'm having problem with high pings. Windows 7 with on-board realtek NIC. Fresh install, fully updated, drivers installed from included CD. When I start pinging router (direct 1Gb ethernet connection, 1 hop), pings start at <1ms (which is fine) and after a while they jump to 300-1000ms. I loaded up live ubuntu to test if the problem might be in HW. It's not, in ubuntu pings were always <1ms. I also noticed that when I start using connection somehow, pings go down to 1ms, but go back up when I stop using it (tested by accessing live camera feed on LAN). Power Options set to max performance. I disabled Interrupt Moderation on the NIC, didn't help. I tested it in the safe mode with networking, same problem there. It slows down our client-server based programs and I have no idea what's causing it. All I could google up was that disabling Interrupt Moderation would help, it didn't though. Anyone had similar problems? tl;nr: Computer is giving high pings to router when idle and normal pings when network is under load, it slows down our software significantly.

    Read the article

  • Syntax error at '{'; expected '}' when using nagios in puppet

    - by jiangchengwu
    It's a big problem to me, because I'm not familiar with puppet. ERROR on the puppetmaster: debug: importing '/etc/puppet/manifests/nodes/group-1.pp' err: Could not parse for environment production: Syntax error at '{'; expected '}' at /etc/puppet/manifests/nodes/group-1.pp:6 ERROR on the puppet client: err: Could not retrieve catalog from remote server: Error 400 on SERVER: Could not parse for environment production: Syntax error at '{'; expected '}' at /etc/puppet/manifests/nodes/group-1.pp:6 in group-1.pp: node 'group1' { include ntp class { 'nagios::host': #this is line 6 nodename => $clientcert, appname => 'test', } } nagios::host in module module/nagios/host.pp code are here: class nagios::host($nodename, $hostgroup) { file { '/usr/lib/nagios/plugins': mode = "755", require = Package["nagios-plugins"], } ... @@nagios_service { "${nodename}_check_ssh": ensure => present, use => 'generic-service', host_name => "${nodename}", notification_interval => 60, flap_detection_enabled => 0, service_description => "SSH", check_command => "check_ssh", target => "/etc/nagios3/services.d/${nodename}.cfg", } } and the file module/nagios/init.pp is blank How could I fix it ?

    Read the article

  • Sync desktop Mac environment to laptop

    - by Andrew Vit
    I spend the majority of my time working at my desktop Mac, which I have configured for my web development environment. My spouse has a MacBook for casual use, and I occasionally steal it back when I need to work off-site, or when travelling. The question is how to best synchronize the two so I can switch between them more readily. I've solved a few obvious things by using online services: Email is hosted on IMAP. Working files are in Dropbox. Source code is managed in git. However, the following are things I always miss when jumping on the laptop: Installed Applications (current versions) Installed libraries & utilities (/usr/local) Apache VirtualHosts & other configurations (/etc) Disk image files for VMs My current method is to connect the MacBook via Firewire target mode and rsync the /Users/me home directory, and then cherry-pick the other items I need from Applications, /etc and /usr/local. The problem with this method is that it can be very time consuming due to things like my virtual machine image files, cached emails, etc. How can I make this faster & easier? Can you recommend a solution for configuration management (so I can repeatably install & configure the same software on both), or synchronization (so I can bring the MacBook up to date nightly, over our home network)?

    Read the article

  • Anonymous FTP upload on CentOS 5.2

    - by Craig
    I need to allow users to upload files to an FTP server anonymously. They should not be able to see any other files, or download files. It is a CentOS 5.2 server. I have a separate partition for the the upload area (mounted at /ftp). I have tried to set up vsftpd, followed all the instructions/advice I could find. But, when a user logs in and tries to transfer a file it throws a "553 could not create file." error. If I do a 'pwd' it shows the directory as "/" rather than the anon_root of "/ftp/anonymous". Any attempt to change the remote directory ends with "550 Failed to change directory.". I have a subdirectory "/ftp/anonymous/incoming" that is writable for the uploads SELinux is in permissive mode. I am running version 2.0.5 release 16.el5 of vsftpd. Here is the vsftpd.conf file: anonymous_enable=YES local_enable=YES write_enable=YES local_umask=002 anon_umask=007 file_open_mode=0666 anon_upload_enable=YES anon_mkdir_write_enable=NO dirmessage_enable=YES xferlog_enable=YES connect_from_port_20=YES chown_uploads=YES chown_username=inftpadm xferlog_std_format=YES nopriv_user=nobody listen=YES pam_service_name=vsftpd userlist_enable=YES tcp_wrappers=YES ftp_username=inftpadm anon_root=/ftp/anonymous anon_other_write_enable=NO anon_mkdir_write_enable=NO anon_world_readable_only=NO dirlist_enable=YES Can anyone help?

    Read the article

  • Can't ping guest OS from Windows XP SP3 host running VIC.

    - by Vittal
    Hi, I am running VMware ESX Server 3i Version 3.5.0 and accessing this server using VMware Infrastructure Client Version 2.5.0 on a Windows XP SP3 machine. I have enabled the Microsoft TCP/IP version 6 stack and assigned an IPv6 address (using the netsh command) to the network adapter. The guest OS'es running on ESX Server (includes Win7, W2K8, WinXP) also have IPv6 addresses enabled on their adapters. The adapters are configured to be in VM Network (Bridged mode) and hence have connectivity to the Internet. The VMs are able to ping each other using IPv6 addresses and are also able to ping a physical Win7 machine using IPv6 addresses. However, the Windows XP SP3 machine on which the Client is running is not able to ping any hosts running on ESX Server while the VMs are able to ping this host. Whenever I try to ping from WXP box I get the "Invalid source route specified." error. The WinXP machine is not able to ping the Win7 physical machine too (the same error as above is thrown). Can someone help me understand why I am receiving this error and what I need to do to resolve this error? Thanks, Vittal

    Read the article

  • Ubuntu hard disk getting SATA errors

    - by Henadzy
    I am getting "UNC" errors on a hard disk on Ubuntu 9.10. It slows down my system, applications have not been responding for a long time. But when I mount the filesystem on another computer, it works properly. disk: SAMSUNG HD161HJ (SATA) syslog: Apr 25 00:28:25 vare6gin kernel: [ 885.773839] ata3.00: exception Emask 0x1 SAct 0x1e SErr 0x0 action 0x6 frozen Apr 25 00:28:25 vare6gin kernel: [ 885.773845] ata3.00: Ata error. fis:0x21 Apr 25 00:28:25 vare6gin kernel: [ 885.773861] ata3.00: cmd 60/08:08:3f:00:ad/00:00:10:00:00/40 tag 1 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773864] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773871] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773877] ata3.00: error: { UNC } [...snip 3 similar repeats of last 4 lines; see revision history for full log...] Apr 25 00:28:25 vare6gin kernel: [ 885.773970] ata3: hard resetting link Apr 25 00:28:25 vare6gin kernel: [ 885.773974] ata3: nv: skipping hardreset on occupied port Apr 25 00:28:25 vare6gin kernel: [ 886.240073] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 25 00:28:25 vare6gin kernel: [ 886.256277] ata3.00: configured for UDMA/133 Apr 25 00:28:25 vare6gin kernel: [ 886.256305] ata3: EH complete Apr 25 00:28:27 vare6gin kernel: [ 888.176088] ata3: EH in SWNCQ mode,QC:qc_active 0xF sactive 0xF Apr 25 00:28:27 vare6gin kernel: [ 888.176099] ata3: SWNCQ:qc_active 0xF defer_bits 0x0 last_issue_tag 0x3 Apr 25 00:28:27 vare6gin kernel: [ 888.176102] dhfis 0xF dmafis 0x1 sdbfis 0x0 Apr 25 00:28:27 vare6gin kernel: [ 888.176109] ata3: ATA_REG 0x51 ERR_REG 0x40 Apr 25 00:28:27 vare6gin kernel: [ 888.176113] ata3: tag : dhfis dmafis sdbfis sacitve Apr 25 00:28:27 vare6gin kernel: [ 888.176120] ata3: tag 0x0: 1 1 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176126] ata3: tag 0x1: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176131] ata3: tag 0x2: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176136] ata3: tag 0x3: 1 0 0 1

    Read the article

  • mkvmerge: How to merge two videos, one without audio?

    - by ProGNOMmers
    I have two videos, one without audio (the second). Trying to merge them I have this error: mkvmerge concat1.webm +concat2.webm -o output.webm mkvmerge v5.8.0 ('No Sleep / Pillow') built on Oct 19 2012 13:07:37 Automatically enabling WebM compliance mode due to output file name extension. 'concat1.webm': Using the demultiplexer for the format 'Matroska'. concat2.webm': Using the demultiplexer for the format 'Matroska'. 'concat1.webm' track 0: Using the output module for the format 'VP8'. concat2.webm' track 0: Using the output module for the format 'VP8'. concat2.webm' track 1: Using the output module for the format 'Vorbis'. No append mapping was given for the file no. 1 (concat2.webm'). A default mapping of 1:0:0:0,1:1:0:1 will be used instead. Please keep that in mind if mkvmerge aborts with an error message regarding invalid '--append-to' options. Error: The file no. 0 ('concat1.webm') does not contain a track with the ID 1, or that track is not to be copied. Therefore no track can be appended to it. The argument for '--append-to' was invalid. Is there a way to say to mkvmerge to make the audio track longer? Thank you!

    Read the article

  • When ran as a scheduled task, cannot save an Excel workbook when using Excel.Application COM object in PowerShell

    - by Daniel Richnak
    I'm having an issue where I've automated creating an Excel.Application COM object, add some data into a workbook, and then saving the document as an xlsx. This works fine if: I'm already in Powershell interactive host and either run each command in sequence, or execute as a ps1. I run it from cmd.exe, using the syntax: powershell.exe -command "c:\path\to\powershellscript.ps1" I create a scheduled task in Windows 7 / Server 2008 R2, use the above powershell.exe -command syntax, and use the mode "Run only when the user is logged on". It fails when I modify the same scheduled task, but set it to "run whether the user is logged on or not". Here's a sample script that illustrates the problem I'm having: $Excel = New-Object -Com Excel.Application $Excelworkbook = $Excel.Workbooks.Add() $excelworkbook.saveas("C:\temp\test.xlsx") $excelworkbook.close() I have a theory that the COM object fails somehow if my profile isn't loaded / if it's not performed in a command window. Any ideas on which options to choose when creating the scheduled task, or which options to use when creating the Excel object or using the SaveAs() function? Can anybody reproduce this? I've been able to see this behavior on both a Server 2008 R2 machine, and Windows 7. Haven't tried other platforms.

    Read the article

  • Max. Temp. on Intel Burn Test for Stock Dell Precision T3500

    - by HK1
    I'm troubleshooting an issue on a Dell Precision T3500. As part of my troubleshooting I've decided to try running a stress test using Intel Burn Test software. This machine is a stock configuration with 12GB of RAM and a Xeon W3670 processor (nothing overclocked). When I run IBT using the standard mode, SpeedFan reports a processor temperature in excess of 80C. I've seen numbers as high as 90C but even at that temperature the machine does not become unstable or crash. However, it seems way too high. This processor has a TCase of 67.9C according to Intel's website. I'm guessing that means I'm in the danger zone any time I go over that temperature. I've checked the cooling system and everything looks fine. I've even took out the heat sink and reinstalled it with new thermal compound. This did not appear to make the problem better or worse. Is there a discrepancy somewhere here in the way temperatures are measured or displayed? I've also tried using HWMonitor from CPUID and it reports the same temperatures. Should I just let the Standard Test go and disregard the temperature outputs?

    Read the article

  • Permission Denied for FTP User

    - by Alasdair
    I have an FTP user whose default is /root/ftpuser This user can login fine. The user is the owner of the directory & the directory is even set to 777 permissions. But the user can't upload anything, the display is: Status: Connecting to xx.xxx.xxx.xx:21... Status: Connection established, waiting for welcome message... Response: 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- Response: 220-You are user number 2 of 50 allowed. Response: 220-Local time is now 05:12. Server port: 21. Response: 220-This is a private system - No anonymous login Response: 220-IPv6 connections are also welcome on this server. Response: 220 You will be disconnected after 15 minutes of inactivity. Command: USER ftpuser Response: 331 User ftpuser OK. Password required Command: PASS ********* Response: 230 OK. Current restricted directory is / Command: OPTS UTF8 ON Response: 200 OK, UTF-8 enabled Status: Connected Status: Starting upload of test.html Command: CWD / Response: 550 Can't change directory to /: Permission denied Command: MKD / Response: 550 Can't create directory: Permission denied Command: CWD / Response: 550 Can't change directory to /: Permission denied Command: SIZE /btn.png Response: 550 Can't check for file existence Command: TYPE I Response: 200 TYPE is now 8-bit binary Command: PASV Response: 227 Entering Passive Mode (66,232,106,33,52,218) Command: STOR /test.html Response: 553 Can't open that file: Permission denied Error: Critical file transfer error It's a Linux CentOS 6 server. Any ideas?

    Read the article

< Previous Page | 401 402 403 404 405 406 407 408 409 410 411 412  | Next Page >