  • Centos Xen resizing DomU partition and volume group

    - by thepearson
    I have a setup like so: Dom0 LV | DomU Physical Disk | | XVDA1 XVDA2 (/boot) (DomU PV) | VolGroup00 (DomU VG) | | LogVol00 LogVol01 (swap) (/) I am trying to resize the DomU root Filesystem. (VolGroup00-LogVol01) I realize that I now need to resize the partition XVDA2, however when I try doing this with parted on Dom0 it just tells me "Error: Could not detect file system." So to resize the root part VolGroup-LogVol00 shouldn't the process be: # Shut down DomU xm shutdown domU #Resize Dom0 Logical volume lvextend -L+2G /dev/volumes/domU-vol # Parted parted /dev/volumes/domU-vol # Resize root partition resize 2 START END (This is where I get an error) "Error: Could not detect file system." # add the vm volume group to Dom0 lvm kpartx -a /dev/volumes/domU-vol # resize the domU PV pvresize /dev/mapper/domU-pl (as listed in pvdisplay) # The domU volume group should automatically adjust # resize the DomU lv lvextend -L+2G /dev/VolGroup/LogVol00 And then obviously increase the fs, remove the device from kpartx etc The problem is I dont know how to resize the partition? How do I resize this partition so I can run pvresize on the DomU? Thanks

    Read the article

  • Vertex 2 SSD is running faster than my Vertex 3 SSD?

    - by Kairan
    I used Acronis Disk Director to do a direct clone of my C:\ windows 7 x64 drive from my Vertex 2 to my new Vertex 3 SSD (Just to show the drive software winstall everything is identical.) I ran a performance test on Windows using the Windows Experience Index. The rating I am receiving when booting on the Vertex 2 is 7.5 While I am getting only a rating for the Vertex 3 of 6.9 My understanding is that the read/write speeds of the Vertex 2 is only up to 250MB/sec while the Vertex 3 is up to 500MB/sec. Copying a single file (3GB in size) from the Vertex 3 to itself was getting speed of approx 70-80MB/sec This speed is no better (maybe worse) than what I got from the Vertex 2 I am connected via the SATA 3 port on the motherboard, using an SATA 3 cable Is this issue caused by the drive cloning? Do I have a bad SSD?

    Read the article

  • Fixing Windows 7 hibernation

    - by 80skeys
    I've been mucking around with the partitions on my laptop (I'm an experienced Linux/grub guy) and have somehow ended up affecting the ability of Windows 7 to go into hibernate mode. All other functionality seems to be okay. But when I press Hibernate, it behaves as if it starts to (screen goes dark, a little disk activity) but never powers off and if I move the mouse the login screen instantly comes up. I don't know if Window uses a separate partition for hibernation? There is a 200MB partition on the drive - I seem to recall it was related to diagnostics or some other Windows- boot menu stuff. In any case, wondering if there's some commands I can run to restore the ability to hibernate and also which partitions need to be marked "active" and if there's anything I need to do to the MBR of the hard drive or the MBR of the Windows partition? As I said, Windows boots fine as long as it is designated the Active partition. I just need to fix Hibernation.

    Read the article

  • pcap stream rotation and pruning

    - by pilcrow
    Some of my servers collect a lot of packet data. Is there a utility (or patch to tcpdump(1)) to log a pcap stream to disk which: Rotates based on size of data written Prunes written files, keeping only the N most recent Does not re-use output filenames Is self-contained (Ruling out, e.g., a rotation with external pruning via crond(8)+tmpwatch(8)) Basically I want a multilog or svlogd that groks the pcap record format. The -W filecount option of tcpdump-4.0.0 "prunes" by recycling old filenames, which violates #3 above, forcing me to consult mtimes to determine recency and providing no guarantees against surprise truncation of the log file. The -G option introduces strftime(2)-specifier support in output filenames, which would give me at least second-precision in file names, but I can't figure out how to get pruning to work with this scheme.

    Read the article

  • Windows 7 Can't Get Past Format

    - by Soren
    Just assembled a new machine: MSI 880GM-E41 motherboard 500GB Samsung hard drive AMD Athlon II X4 640 processor 4GB RAM Windows 7 64 Bit LITE-ON Black 4X Blu-ray reader I boot up, start the install. When it gets to the screen to select what partition, the motherboard loses power. It doesnt make sense, I can leave it in the bios settings for a very long time and it doesnt lose power. When it does lose power, the monitor shuts down and the mouse loses power, but the power light stays on. I cannot tell if it is a harware or software problem.

    Read the article

  • How to Shutdown PC by Pressing Power Button without asking "Force Close"?

    - by AgA
    I always Hibernate my PC. Sometimes when I boot, it does not recognize the mouse/keyboard or any USB devices. I've also setup it to go in sleep in 5 minutes. In that case I can't restart the PC so that USB starts working. When I press the Power button then it starts shutdown but asks confirmation twice, one is for shutdown by force confirmation and then there is one more. When my USB is disabled I can't input these options. So I switch off the power. What I want is that upon pressing Power Button it should at once start shutdown without asking any more confirmations System details: Win-7 Home Premium 64 bit Intel i3 530 Asus P montherboard EDIT: It is Desktop PC

    Read the article

  • How do I get my Nvidia monitor position settings (in Linux) to persist after a restart?

    - by machineghost
    I have two monitors, and I run them both in Linux using the proprietary Nvidia drivers with "TwinView". I just installed Linux Mint 13, and since the install after every reboot my monitors come up in the wrong position (the computer thinks the left monitor is on the right). After boot-up I can run the Nvidia config and fix the monitors' position, and I can even save the configuration file successfully. But as soon as I restart again, the monitors re-appear switched. Does anyone have any idea what might be causing this (and more importantly, how I can solve it?)

    Read the article

  • Dell e4300 Random Beeps

    - by Mikey.B
    I’ve noticed that my Dell e4300 Laptop will randomly beep every now and then. The symptoms are virtually identical to the issue described here: http://en.community.dell.com/support-forums/laptop/f/3518/t/19314488.aspx Any ideas why? I thought it might be related to hard drive activity so I downloaded the western digital disk utility and all tests check out fine. It’s not a big deal and it only beeps once every few days. I just want to make sure there isn’t a larger problem looming. =) -M

    Read the article

  • MySql Data Loss - post mortem analysis - RackSpace Cloud Server

    - by marfarma
    After a recent 'emergency migration' of a RS cloud server, the mysql databases on our server snapshot image proved to be days out of date from the backup date. And yet files that were uploaded through the impacted webapp had been written to the file system. Related metadata that was written to the database was lost, but the files themselves were backed-up. Once I was able to manually access the mysql data files before the mysql server started (server was configured to start mysql on boot), I was able to see that the update time for ib_logfile1, ib_logfile0 and ibdata1 was days old. As with this poster, mysql data loss after server crash, it's as if some caching controller had told the OS / mysql server that it had committed data that was still in cache, and it was lost instead of flushed. I can't quite wrap my head around how the uploaded files got written but the database data did not. I would have thought that any cache would have flushed system wide, rather than process by process. Any suggestions as to how this might have happened?

    Read the article

  • Locate rogue DHCP server

    - by Farseeker
    I know this is a serious long shot, but here we go. In the past week or so, for users connected to a particular switch in our network (there are four dumb switches all connected, and it only affects SOME, not all, users on the one switch) are getting DHCP addresses from a rogue DHCP server. I have physically checked every cable plugged into the switch in question to make sure that none of them have a router or wifi point attached to it. I know the IP of the DHCP server, but I cannot ping it, and it does not have a web interface. Does anyone have any suggestions on what I can do to locate it or shut it down? Unfortuantely all the switches are unmanaged, and as mentioned, there's no physical device (that I can find) plugged in to anything. It's getting critical, because it's screwing up the PXE boot of a whole bunch of thin clients.

    Read the article

  • How can I recover a huge folder that's been converted to a zero kb file on an NTFS partition?

    - by aalaap
    I have a 1TB drive with two 500GB partitions. One of them is being used as a Mac OS X Time Machine back up drive and the other one was NTFS and being used for storage. I had my entire 'iTunes Music' folder stored on it. Recently, there were some errors on the NTFS drive that caused chkdsk to run when in Windows, and it removed a lot of corrupt files. In this process, it converted my 'iTunes Music' folder into one zero KB file. How can I recover this? The partitions are intact and the other data on the disk is still accessible. It's just the 'iTunes Music' folder that's gone.

    Read the article

  • Windows 7 taskbar thumbnails fail to appear

    - by Vasiliy Borovyak
    Several hours after each boot the Windows 7 taskbar thumbnails stops appear. Click the currently opened window (it should not be a group of windows) - it will collapse. Than hover the mouse over any other window icon, wait a second, and nothing happens. After that no thumbnail appear at all. There is the way to return them back. You need to open two windows of the same application (group of windows), and click their group - two thumbnails should appear. After that thumbnails are back, until you click currently opened window... It there a way to fix it?

    Read the article

  • Late 2008 Unibody MacBook Pro, Snow Leopard EFI 1.8 downgrade

    - by SiLo
    Question: Does anyone know of an EFI downgrade for user on 1.8? I have found a 1.7 to 1.6 downgrade, but once on 1.8 this downgrade no longer works. Background: After upgrading to Snow Leopard, and installing the EFI 1.8 update (as recommended by Software Update), I have lost the ability to burn discs. This also includes when using external burners and when booting into Vista using Bootcamp. Other seemingly related problems to the EFI I have are, chronic overheating, random temporary beachball lockups, longer boot times. These 'other' problems have been solved for other users who experienced these problems on EFI 1.7, but were able to rollback to 1.6. I am looking for a solution that does not require sending my computer back to Apple.

    Read the article

  • I reinstalled OS X and the system was the same as before

    - by slhck
    Strange thing happened. I want so sell my old Macbook and therefore used a disk image of the Snow Leopard DVD that I restored onto an external drive. I booted off the drive and went through the installation steps. Now I really would like to perform "archive and install", as there might be some files that I need later, but I didn't see the option. The only options for installation I had, were, including others, optional printer drivers and Rosetta. So I just clicked through and I wasn't given any other option. After about 45 minutes, my system booted again, and voila, there was my old system. Nothing changed. How should I proceed to actually reset the system? All I have is that Snow Leopard DVD image.

    Read the article

  • Which linux distro for a laptop in windows environmet?

    - by Dev er dev
    I just got new laptop at work. What would you recommend as a linux distribution for it? All other developers are working under windows, and use windows tools. I'm currently using ArchLinux, but want to change it. I don't want to waste time configuring wireless, windows network shares, network pritners, projector, etc ... I want this stuff to just work, while still having sane and stable development evironment and tools. Is Ubuntu a good choice for this? I use gentoo at home, but don't think it is a good match for work environmet. EDIT: Note that we are working on cross platform apps, and deployment platform is almost always linux. There are very few windows apps that I have to use (like MS Project). It is just that everything else is windows centric. I use linux because I feel more productive with it, even if I have to dual boot to edit MS Project files.

    Read the article

  • Vista Startup Repair cannot repair my Toshiba Laptop (L300D)

    - by tdot
    I installed some updates, and now the computer doesn't boot up, it just keep's telling me to go to repair, which doesn't fix the problem. I see the BSOD on startup, but it flashes by too quick. (I also don't have Vista on DVD to do a reinstall if I need to) This is what I get from the Startup Repair details Problem Event Name StartupRepair V2 Problem Signature 01: External Media Problem Signature 02: 6.0.6001.18000.6.0.6001.18000 Problem Signature 03: 2 Problem Signature 04: 131074 Problem Signature 05: BadDriver Problem Signature 06: NoBootFailure Problem Signature 07: 0 Problem Signature 08: 0 Problem Signature 09: unknown Problem Signature 10: 1168 OS Version: 6.0.6001.2.1.0.256.1 Local ID: 1033 Any help will be appreciated. Thanks.

    Read the article

  • Postgres 9.0 locking up, 100% CPU

    - by Jake
    We are having a problem where our Postgres 9.0 server occasionally locks up and kills our webapp. Restarting Postgres fixes the problem. Here's what I've been able to observe: First, usage of one CPU jumps to 100% for a few minutes Disk operations drop to ~0 during this time Database operations drop to 0 (blocks and tuples per sec) Logs show during this time: WARNING: worker took too long to start; cancelled WARNING: worker took too long to start; cancelled No Queries in logs (only those over 200ms are logged) No unusually long-running queries logged before or during Then the second CPU jumps to 100% The number of postgres processes jumps from the usual 8-10 to ~20 Matched by a spike in Postgres Blocks per second (about twice normal) Logs show LOG: could not accept SSL connection: EOF detected Queries are running but slow Restarting postgres returns everything to normal Setup: Server: Amazon EC2 Large Ubuntu 10.04.2 LTS Postgres 9.0.3 Dedicated DB server Does anyone have any idea what's causing this? Or any suggestions about what else I should be checking out?

    Read the article

  • Problem restarting my Ubuntu system

    - by VoY
    Whenever I try to restart my Ubuntu either from the command line by typing reboot or in GNOME the computer goes from X to console, starts the shutdown process and then a message saying "[ some number ] Starting new kernel" appears on the screen and the computer goes back to X login screen. I suspect this must have something to do with nvidia drivers, because it seemed to have appeared around the time I bought a new graphic card. Also, when I reboot the second time I see weird graphical artifacts on the screen. When I boot from ubuntu live cd I can reboot just fine. I used jaunty, recently I switched to karmic with no change. This bug is very annoying, because I have to hard reset my computer in order to reboot. Also not good for the filesystems, I suspect. Can you suggest a way to debug the cause or if not at least the easiest way to go about reinstalling ubuntu without losing customizations/settings/data?

    Read the article

  • Build a RAID-5 USB Array or NAS?

    - by TK Kocheran
    I'm looking to build a RAID-5 or RAID-6 hard disk array to be used as a centralized backup location for my home network. I have a lot of 4-8GB DVD ISO files which I intend to serve over the network to my TV using DLNA or something similar. I need decent write times, fast read times, and preferably a way to connect this array to my network router over USB. I'll probably be using ext3/4 on it (I'd use btrfs if my router supported it :-[). Is there a way to build a RAID array that is accessible over USB? I'm kind of new to this and most guides assume you're running a RAID array inside your machine. I need at least 5TB of space, and I need redundancy, so I prefer RAID-6. How can I go about accomplishing this?

    Read the article

  • Windows XP-64 loses audio sounds, drive letters... why?

    - by Ira Baxter
    Until sometime in early December, I had a wonderfully functioning XP-64 system. It was configured to auto download/install MS patches. I occassionally update the software on it, e.g. Open Office, Adobe Reader, Skype, but I don't fetch hundreds of tools or anything much beyond what I just mentioned. In December, suddenly my audio stopped, and drive letters assigned to various mount points on other machines quit being available. Apparantly, the services that support these (and some others) are now not starting up when I boot/login. There isn't anything obvious in the event log. If I manually restart the associated services, these facilities come back on line and work for awhile (a day) but pretty soon the problem reappears. I don't reboot very often, nor do I log out out much. Hints?

    Read the article

  • Apache port forwarding with ZTE ZXV10 W300 router (provider specific firmware)

    - by dannote
    I'm trying to configure port forwarding for Apache 2.2 installed on Windows XP SP3 with ZTE ZXV10 W300 router. The computer has a static IP 192.168.1.2. Port forwarding is configured as following: Enable true Name Apache Protocol TCP (also tried TCP and UPD) WAN Host Start IP Address empty WAN Host End IP Address empty WAN Connection stream WAN Start Port 8080 WAN End Port 8080 LAN Host IP Address 192.168.1.2 LAN Host Start Port 8080 LAN Host End Port 8080 Port 8080 is open for both TCP and UPD in Windows Brandmauer. Apache configuration: Listen 192.168.1.2:8080 Router Firmware: Hardware Version V1.0.01 Software Version V8.0.02T03_CFA Boot Loader Version V1.1.2 The provider is COMSTAR. I'm not sure but it's said they flash routers with modified firmware. I have also tried to set up Bitcomet port forwarding on port 13514 and failed.

    Read the article

  • Configure Nagios To Alert Depending On Host Group That Service Alert Originates From

    - by StrangeWill
    So my setup: Services are shared between all hosts (CPU/RAM/Disk/Services). Hosts are split into two main groups: "Production" and "Development". We have two contact groups: "Production" and "Development". Lets say my development SQL server runs low on RAM, I want it to only alert those in "Development" contact group (this service is of course assigned to a host in the "Development" host group, using the shared RAM monitoring service). I'm pretty much stumped on this... I can't configure it at the service level (they're shared there), and I can't seem to get escalations to do it for me either... Do I need to use service groups along with escalations and bite the bullet on building that list? Or am I missing something stupidly simple? I'm using Centreon for configuration if that helps.

    Read the article

  • mac: How to mount ejected external hdd again

    - by Maurice Kroon
    I've used my WD My Book 1TB for quite some time now. I always simply unplug it without officially 'ejecting' it. However, yesterday I did eject it (the partitions) before unplugging it. However, now, when i reconnect the hdd, it does not show the drives. It only shows the WD SmartWare partition (which is empty btw). The rest doesn't start. Does anyone know how to mount an unmounted disk? thx in advance!

    Read the article

  • Big square ads appear in lower right corner of both IE and Chrome

    - by BrianK
    In both IE and Chrome, large ads appear in the lower right corner of the browser window. Sometime they look reputable like for Microsoft, but sometimes they are big flashing boxes that say "You have won". Right now I am looking at "Need to lose 30 lbs?" I ran Microsofot Security Essentials and it didn't find anything. I then ran Windows Defender Offline (boot from CD). WDO found five things lincluding browser hijack that caused the wrong page to appear after clicking a link. It reported that it cleaned successfully, after which I ran a quick scan to confirm. After rebooting I still see the ads. Do I still have an infection? Any other tools to try? What about ComboFix? Thanks Update: Here's a screenshot - on superuser

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article