Search Results

Search found 24403 results on 977 pages for 'matt case'.

Page 425/977 | < Previous Page | 421 422 423 424 425 426 427 428 429 430 431 432  | Next Page >

  • Who practices, or is likely to practice, the IEEE Software Engineering? [closed]

    - by user72757
    There is an interesting issue in Software Engineering which I'd like to explore. The issue is firstly what is and what is not software engineering. Secondly, if software engineering is what the IEEE defines it to be, what are good examples of companies which practice the SE? Detailed question: Software engineering (SE) is the application of a systematic, disciplined, quantifiable approach to the design, development, operation, and maintenance of software, and the study of these approaches; that is, the application of engineering to software. [updated definition, originating in 610.12-1990 - IEEE Standard Glossary of Software Engineering Terminology] If we consider as SE only those approaches that 100% match the above definition, we naturally get to SWEBOK (Software Engineering Body of Knowledge) which is created by the IEEE and the ACM. I'm seeking the answer to this: How can I find a company outside the defence industry which practices the SE as defined by IEEE? Clues: SE originates in 1968 NATO conference. The Software Engineering Institute (SEI) is based in the US at Carnegie Mellon University. Funding of the SEI is largely done by the US DoD. Defence industry uses the SE and sometimes has a partnership with the IEEE (as in case of Boeing). Possible decomposition of my big question into smaller chunks: a) Where is anyone who acknowledges the IEEE Software Engineering standards at work and perhaps even uses some of them? http://cs.hbg.psu.edu/cmpsc487/IEEEStds_List.htm b) Where can I find a person or a company building around SWEBOK? http://www.computer.org/portal/web/swebok/html/contents c) What is an example of a company professionally using CSDP (apart from those at IEEE website)? Does anyone have any possible contribution to this question?

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Squeezing hardware

    - by [email protected]
    It's very common that high availability means duplicate hardware so costs grows up.Nowadays, CIOs and DBAs has the main challenge of reduce the money spent increasing the performance and the availability. Since Grid Infrastructure 11gR2, there is a new feature that helps them to afford this challenge: Server PoolsNow, in Grid Infrastructure 11gR2, you can define server pools across the cluster setting up the minimum number of servers, the maximum and how important is the pool.For example:Consider  that "Velasco, Boixeda & co"  has 3 apps in a 6 servers cluster.First One is the main core business appSecond one is Mid RangeAnd third it's a database not very important.We Define the following resource requirements for expected workload:1- Main App 2 servers required2- Mid Range App requires 1 server3- Is not a required app in case of disasterThe we define 3 server pools across the cluster:1- Main pool min two servers, max three servers, importance four2- Mid pool, min one server max two servers, importance two3- test pool,min zero servers, max one server, importance oneSo the initial configuration is:-Main pool has three servers-Mid pool has two servers-Test pool has one serverLogically, we can see the cluster like this:If any server fails, the following algorithm will be applied:1.-The server pool of least importance2.-IF server pools are of the same importance,   THEN then the Server Pool that has more than its defined minimum servers Is chosenHope it helps 

    Read the article

  • Sharing laptop's internal optical drive running windows XP Media Center Edition with Netbook running

    - by Col
    just got a new HP netbook with no optical drive and guide said I should be able to share the optical drive of another windows computer. The netbook is running Windows 7 and the laptop, also HP, with the internal optical drive is running Windows XP Media Center Edition. I have wireless network that both the laptop and netbook access without a problem. The instructions did not seem to work in my case. When I right clicked on Properties of the optical drive and went to the Sharing tab, there was no selction for Advanced Sharing as the instructions said. XP made me go to Network wizard and set up a network, (which I already had). After doing that I could not access the drive from Windows 7. Has anyone benn able to do this?

    Read the article

  • How to open a VirtualBox (.VDI) Virtual Machine

    - by [email protected]
     How to open a .VDI Virtual MachineSometimes someone share with us one Virtual machine with extension .VDI, after that we can wonder how and what with?Well the answer is... It is a VirtualBox - Virtual Machine. If you have not downloaded it you can do this easily, just follow this post.http://listeningoracle.blogspot.com/2010/04/que-es-virtualbox.htmlorhttp://oracleoforacle.wordpress.com/2010/04/14/ques-es-virtualbox/Ok, Now with VirtualBox Installed open it and proceed with the following:1. Open the Virtual File Manager. 2. Click on Actions ? Add and select the .VDI fileClick "Ok"3.  A new Virtual machine will be displayed, (in this Case, an OEL5 32GB Virtual Machine is available.)4. This step is important. Once you have open the settings, under General option click the advanced settings. Here you must change the default directory to save your Snapshots; my recommendation set it to the same directory where the .Vdi file is. Otherwise you can have the same Virtual Machine and its snapshots in different paths.5. Now Click on System, and proceed to assign the correct memory and define the processors for the Virtual machine. Note: Enable  "Enable IO APIC" if you are planning to assign more than one CPU to the Virtual Machine.6. Associated the storage disk to the Virtual machineThe disk must be selected as IDE Primary Master. 7. Well you can verify the other options, but with these changes you will be able to start the VM. Note: Sometime the VM owner may share some instructions, if so follow his instructions.8. Click Ok and Push Start Button, and enjoy your Virtual Machine

    Read the article

  • HPET for x86 BSP (how to build it for WCE8)

    - by Werner Willemsens
    Originally posted on: http://geekswithblogs.net/WernerWillemsens/archive/2014/08/02/157895.aspx"I needed a timer". That is how we started a few blogs ago our series about APIC and ACPI. Well, here it is. HPET (High Precision Event Timer) was introduced by Intel in early 2000 to: Replace old style Intel 8253 (1981!) and 8254 timers Support more accurate timers that could be used for multimedia purposes. Hence Microsoft and Intel sometimes refers to HPET as Multimedia timers. An HPET chip consists of a 64-bit up-counter (main counter) counting at a frequency of at least 10 MHz, and a set of (at least three, up to 256) comparators. These comparators are 32- or 64-bit wide. The HPET is discoverable via ACPI. The HPET circuit in recent Intel platforms is integrated into the SouthBridge chip (e.g. 82801) All HPET timers should support one-shot interrupt programming, while optionally they can support periodic interrupts. In most Intel SouthBridges I worked with, there are three HPET timers. TIMER0 supports both one-shot and periodic mode, while TIMER1 and TIMER2 are one-shot only. Each HPET timer can generate interrupts, both in old-style PIC mode and in APIC mode. However in PIC mode, interrupts cannot freely be chosen. Typically IRQ11 is available and cannot be shared with any other interrupt! Which makes the HPET in PIC mode virtually unusable. In APIC mode however more IRQs are available and can be shared with other interrupt generating devices. (Check the datasheet of your SouthBridge) Because of this higher level of freedom, I created the APIC BSP (see previous posts). The HPET driver code that I present you here uses this APIC mode. Hpet.reg [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Hpet] "Dll"="Hpet.dll" "Prefix"="HPT" "Order"=dword:10 "IsrDll"="giisr.dll" "IsrHandler"="ISRHandler" "Priority256"=dword:50 Because HPET does not reside on the PCI bus, but can be found through ACPI as a memory mapped device, you don't need to specify the "Class", "SubClass", "ProgIF" and other PCI related registry keys that you typically find for PCI devices. If a driver needs to run its internal thread(s) at a certain priority level, by convention in Windows CE you add the "Priority256" registry key. Through this key you can easily play with the driver's thread priority for better response and timer accuracy. See later. Hpet.cpp (Hpet.dll) This cpp file contains the complete HPET driver code. The file is part of a folder that you typically integrate in your BSP (\src\drivers\Hpet). It is written as sample (example) code, you most likely want to change this code to your specific needs. There are two sets of #define's that I use to control how the driver works. _TRIGGER_EVENT or _TRIGGER_SEMAPHORE: _TRIGGER_EVENT will let your driver trigger a Windows CE Event when the timer expires, _TRIGGER_SEMAPHORE will trigger a Windows CE counting Semaphore. The latter guarantees that no events get lost in case your application cannot always process the triggers fast enough. _TIMER0 or _TIMER2: both timers will trigger an event or semaphore periodically. _TIMER0 will use a periodic HPET timer interrupt, while _TIMER2 will reprogram a one-shot HPET timer after each interrupt. The one-shot approach is interesting if the frequency you wish to generate is not an even multiple of the HPET main counter frequency. The sample code uses an algorithm to generate a more correct frequency over a longer period (by reducing rounding errors). _TIMER1 is not used in the sample source code. HPT_Init() will locate the HPET I/O memory space, setup the HPET counter (_TIMER0 or _TIMER2) and install the Interrupt Service Thread (IST). Upon timer expiration, the IST will run and on its turn will generate a Windows CE Event or Semaphore. In case of _TIMER2 a new one-shot comparator value is calculated and set for the timer. The IRQ of the HPET timers are programmed to IRQ22, but you can choose typically from 20-23. The TIMERn_INT_ROUT_CAP bits in the TIMn_CONF register will tell you what IRQs you can choose from. HPT_IOControl() can be used to set a new HPET counter frequency (actually you configure the counter timeout value in microseconds), start and stop the timer, and request the current HPET counter value. The latter is interesting because the Windows CE QueryPerformanceCounter() and QueryPerformanceFrequency() APIs implement the same functionality, albeit based on other counter implementations. HpetDrvIst() contains the IST code. DWORD WINAPI HpetDrvIst(LPVOID lpArg) { psHpetDeviceContext pHwContext = (psHpetDeviceContext)lpArg; DWORD mainCount = READDWORD(pHwContext->g_hpet_va, GenCapIDReg + 4); // Main Counter Tick period (fempto sec 10E-15) DWORD i = 0; while (1) { WaitForSingleObject(pHwContext->g_isrEvent, INFINITE); #if defined(_TRIGGER_SEMAPHORE) LONG p = 0; BOOL b = ReleaseSemaphore(pHwContext->g_triggerEvent, 1, &p); #elif defined(_TRIGGER_EVENT) BOOL b = SetEvent(pHwContext->g_triggerEvent); #else #pragma error("Unknown TRIGGER") #endif #if defined(_TIMER0) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD comparator = READDWORD(pHwContext->g_hpet_va, Tim0_ComparatorReg + 0); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 0); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 0 %06d %08X %08X", pHwContext->g_id, i++, currentCount, comparator)); #elif defined(_TIMER2) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD previousComparator = READDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0); pHwContext->g_counter2.QuadPart += pHwContext->g_comparator.QuadPart; // increment virtual counter (higher accuracy) DWORD comparator = (DWORD)(pHwContext->g_counter2.QuadPart >> 8); // "round" to real value WRITEDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0, comparator); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 2); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 2 %06d %08X %08X (%08X)", pHwContext->g_id, i++, currentCount, comparator, comparator - previousComparator)); #else #pragma error("Unknown TIMER") #endif } return 1; } The following figure shows how the HPET hardware interrupt via ISR -> IST is translated in a Windows CE Event or Semaphore by the HPET driver. The Event or Semaphore can be used to trigger a Windows CE application. HpetTest.cpp (HpetTest.exe)This cpp file contains sample source how to use the HPET driver from an application. The file is part of a separate (smart device) VS2013 solution. It contains code to measure the generated Event/Semaphore times by means of GetSystemTime() and QueryPerformanceCounter() and QueryPerformanceFrequency() APIs. HPET evaluation If you scan the internet about HPET, you'll find many remarks about buggy HPET implementations and bad performance. Unfortunately that is true. I tested the HPET driver on an Intel ICH7M SBC (release date 2008). When a HPET timer expires on the ICH7M, an interrupt indeed is generated, but right after you clear the interrupt, a few more unwanted interrupts (too soon!) occur as well. I tested and debugged it for a loooong time, but I couldn't get it to work. I concluded ICH7M's HPET is buggy Intel hardware. I tested the HPET driver successfully on a more recent NM10 SBC (release date 2013). With the NM10 chipset however, I am not fully convinced about the timer's frequency accuracy. In the long run - on average - all is fine, but occasionally I experienced upto 20 microseconds delays (which were immediately compensated on the next interrupt). Of course, this was all measured by software, but I still experienced the occasional delay when both the HPET driver IST thread as the application thread ran at CeSetThreadPriority(1). If it is not the hardware, only the kernel can cause this delay. But Windows CE is an RTOS and I have never experienced such long delays with previous versions of Windows CE. I tested and developed this on WCE8, I am not heavily experienced with it yet. Internet forum threads however mention inaccurate HPET timer implementations as well. At this moment I haven't figured out what is going on here. Useful references: http://www.intel.com/content/dam/www/public/us/en/documents/technical-specifications/software-developers-hpet-spec-1-0a.pdf http://en.wikipedia.org/wiki/High_Precision_Event_Timer http://wiki.osdev.org/HPET Windows CE BSP source file package for HPET in MyBsp Note that this source code is "As Is". It is still under development and I cannot (and never will) guarantee the correctness of the code. Use it as a guide for your own HPET integration.

    Read the article

  • Fatal Scroll&hellip;

    - by farid
    Hi. Actually I am a glad to writing with geekwithblogs service! but I decided to write a blog to improve my skills on different aspects. This post’s title is “Fatal Scroll”. Motivation for this post was the process of changing my blog theme. When I was trying to change the blog theme, encountered a killing scroll in configuration page of blog. you can see the sample in this picture. (10 inch screen) All I saw in my screen without scrolling was that. I tried to change my blog a few times. but the scroll slows down my try !! after all I gave up changing the FK theme!! In my opinion there is a check list for designing efficient and useful forms.(if you care about it!!) First of all, don’t forget wide range of screen sizes and screen resolutions. Second, always consider the cost of checking the changes made in fields. Third, never forget the scroll. scroll should not hide any main functionality (like save in this case). Forth, don’t use real data to preview the result. (like loading full blog to check new theme) and don’t forget didn’t say this list is a definitive list data entry form usability testing!  That’s it! MY FIRST BLOG POST!!

    Read the article

  • Windows Resource Monitoring Programs

    - by Sal
    I work at a small tech start up managing websites with our own in house server side code. (In production, we use Windows Server 2008 boxes, running Java 6. In our dev boxes, we use Windows 7 running Java 7.) Recently, we had an issue where some of our boxes in production failed, and we didn't have means of trouble shooting, since we keep little to no monitoring logs about a given box's CPU/memory/RAM usage, etc. So, I'm wondering if there is some commercial/freeware that's the standard for performance monitoring/logging. Essentially, I'm just looking for an analytics system that is similar to the Windows Task Manager or the Resource Monitor, that serializes all of its data periodically. Ideally, I'd like to find a program that's also extensible, in case I'd like to add addition monitors in the future.

    Read the article

  • Copying files locally on a network folder

    - by Altay_H
    I noticed that copying a large file from one location on a network drive to another location on the same network drive takes much longer than copying it locally. Instead of copying the file locally, the network computer sends the file to my remote computer, which sends it back to the same network computer. This means the files are being transferred over the network completely unnecessarily. Is there a way to fix this issue? It's becoming a real hassle to manage the video files on my network drive. Note: This is the case with both Windows and Linux (using Samba) network folders.

    Read the article

  • Passing values between Activities using MonoDroid

    - by Wallym
    Been doing some work in MonoDroid and found that I needed to pass a user entered value from on Activity to another Activity in MonoDroid.  Here's how I did it. In my sending Activity, I need to take some user user entered data and send it to my second activity.  Here is the code:             string UserId = Convert.ToString(et.Text);            if (!String.IsNullOrEmpty(UserId))            {                Intent i = new Intent();                i.SetClass(this, typeof(CustomList));                i.AddFlags(ActivityFlags.NewTask);                i.PutExtra("TwitterId", UserId);                StartActivity(i);            }  In this code, I have called .PutExtra and  passed it with a key.  In this case, I am passing a Twitter id.  In the code that is receiving the data, the code to retrieve the Twitter id is: string twitterId = Intent.GetStringExtra("TwitterId"); The call to GetStringExtra() returns the value passed on the key.

    Read the article

  • Scene Graph for Deferred Rendering Engine

    - by Roy T.
    As a learning exercise I've written a deferred rendering engine. Now I'd like to add a scene graph to this engine but I'm a bit puzzled how to do this. On a normal (forward rendering engine) I would just add all items (All implementing IDrawable and IUpdateAble) to my scene graph, than travel the scene-graph breadth first and call Draw() everywhere. However in a deferred rendering engine I have to separate draw calls. First I have to draw the geometry, then the shadow casters and then the lights (all to different render targets), before I combine them all. So in this case I can't just travel over the scene graph and just call draw. The way I see it I either have to travel over the entire scene graph 3 times, checking what kind of object it is that has to be drawn, or I have to create 3 separate scene graphs that are somehow connected to each other. Both of these seem poor solutions, I'd like to handle scene objects more transparent. One other solution I've thought of was traveling trough the scene graph as normal and adding items to 3 separate lists, separating geometry, shadow casters and lights, and then iterating these lists to draw the correct stuff, is this better, and is it wise to repopulate 3 lists every frame?

    Read the article

  • In MySQL 5.1 InnoDB, does the maximum length of a VARCHAR affect secondary index size?

    - by e_tothe_ipi
    Assuming the data is the same either way, does the maximum length of the VARCHAR affect the space usage of a secondary index? Does InnoDB use fixed length records for indexes? Assume that we're talking about MySQL 5.1, with the InnoDB COMPRESSED table format and that the field in question is defined as a VARCHAR with some length less than or equal to 255 (so that it uses only one byte for the offset). Here is the use case: I have a server with a very large table (several gigabytes). One of the fields is currently VARCHAR(7). We need it a little longer and we are thinking of making it VARCHAR(255), but we are worried that it bloat the index.

    Read the article

  • How to open a VirtualBox (.VDI) Virtual Machine

    - by [email protected]
     How to open a .VDI Virtual MachineSometimes someone share with us one Virtual machine with extension .VDI, after that we can wonder how and what with?Well the answer is... It is a VirtualBox - Virtual Machine. If you have not downloaded it you can do this easily, just follow this post.http://listeningoracle.blogspot.com/2010/04/que-es-virtualbox.htmlorhttp://oracleoforacle.wordpress.com/2010/04/14/ques-es-virtualbox/Ok, Now with VirtualBox Installed open it and proceed with the following:1. Open the Virtual File Manager. 2. Click on Actions ? Add and select the .VDI fileClick "Ok"3.  A new Virtual machine will be displayed, (in this Case, an OEL5 32GB Virtual Machine is available.)4. This step is important. Once you have open the settings, under General option click the advanced settings. Here you must change the default directory to save your Snapshots; my recommendation set it to the same directory where the .Vdi file is. Otherwise you can have the same Virtual Machine and its snapshots in different paths.5. Now Click on System, and proceed to assign the correct memory and define the processors for the Virtual machine. Note: Enable  "Enable IO APIC" if you are planning to assign more than one CPU to the Virtual Machine.6. Associated the storage disk to the Virtual machineThe disk must be selected as IDE Primary Master. 7. Well you can verify the other options, but with these changes you will be able to start the VM. Note: Sometime the VM owner may share some instructions, if so follow his instructions.8. Click Ok and Push Start Button, and enjoy your Virtual Machine

    Read the article

  • Cheap Bulk Domain Registration

    - by Panoy
    I have 6-7 domain names that I have thought of and I'm planning to buy it in bulk so that I can save. Or am I wrong on this? In my case, since its my first time to this hosting/domain registration, I only knew of GoDaddy with regards to domain registration. Questions: Will I lose out if I chose a cheap domain registrar compared to one that's popular? For a newbie like me, what companies can you recommend for me to register domain names in bulk for cheap or affordable price? I notice that some prices are higher because they offer support and customer service? Aren't those servers not reliable at all? I've heard of some domain registrars that they're increasing their prices every renewal? Is that just natural in a business sense for these domain registrars? Before posting this, I've been reading about NameCheap.com, and I'm considering registering for them unless you have other good choices to give me. I'll appreciate every suggestion or advice you can give.

    Read the article

  • Where do SATA drives get their power when using a PCI SATA controller on oler PCs?

    - by Sukima
    I've been looking into PCI SATA controller cards online for an older PC and noticed that the ports only have the SATA cable connector and the Power supply does not have the SATA power connectors. I also had a few external eSATA drives which don't power up unless I also plugin the USB cable. Therefore I realize that SATA and eSATA do not carry power and need power else where. When converting older PCs to use a PCI SATA controller how do you provide power to the SATA drives? Anticipating the answer to be some kind of converter cable (which I was unable to search for) then can older power supplies handle added drives? (Assuming a 4 port SATA controller means 4 more drives the power supply has to endure). Or do you have to get a second poer supply and kinda jerry-rig it into an old case?

    Read the article

  • Installing Multiple OWB Patches

    - by [email protected]
    When an OUBI bug requires a fix to the Oracle Warehouse Builder (OWB) code, the fix is delivered as an MDL export file that will need to be imported and deployed in OWB. If more than one bug is being patched, then a recent question came in that asked if it would be possible to import one after the next, and then do the deploy steps once? The answer is Yes, all of the imports can be done before any of objects are deployed. Once all of the objects have been deployed, then the TCL scripts that need to be rerun can be run, and then the objects that were changed can be deployed. The order that the MDL files are loaded does not matter unless the same object is in two or more MDL files. In that case, the latest MDL file should be loaded last. For example, if two MDL files both contain changes to the SPLMAP_F_RECENT_CREW mapping, and one was created on January 2, 2009 and the second one was created on March 14, 2009, then the January 2 file should be loaded first and the March 14 file should be loaded second. Note that if the MDL files are always loaded in the order that they were created by Release Services, then this will work correctly.

    Read the article

  • Redmine on Redhat/CentOS 5 Without using virtual hosts

    - by flyclassic
    I've have followed all the steps to install Redmine on CentOS 5, except for the Apache part: http://www.redmine.org/projects/redmine/wiki/HowTo_install_Redmine_on_CentOS_5 I do not want to configure a virtualhost as we are not using virtual hosts. Can I configure Redmine to run with http://hostname/redmine? Apparently it doesn't work for my case. Redmine was extracted in to the webserver document root /var/www/html/ called /var/www/html/redmine What I did was added a redmine.conf to /etc/httpd/conf.d/ with the following configuration and restarted the server: <Location "/redmine"> Options Indexes ExecCGI FollowSymLinks -MultiViews Order allow,deny Allow from all AllowOverride all PassengerEnabled On RailsBaseURI /var/www/html/redmine RailsEnv production </Location> now i got this error Further information about the error may have been written to the application's log file. Please check it in order to analyse the problem. Error message: No such file or directory - config/environment.rb Exception class: Errno::ENOENT Application root: /var/www/html Where have I gone wrong?

    Read the article

  • LibGDX Boid Seek Behaviour

    - by childonline
    I'm trying to make a swarm of boids which seek out the mouse position and move towards it, but I'm having a bit of a problem. The boids just seem to want to go to upper-right corner of the game window. The mouse position seems influence the behavior a bit, but not enough to make the boid turn towards it. I suspect there is a problem with the way LibGDX handles its coordinate system, but I'm not sure how to fix it I've uploaded the eclipse project here! Also here are the relevant bits of my code, in case you see something obviously wrong: public Agent(){ _texture = GdxGame.TEX_AGENT; TextureRegion region = new TextureRegion(_texture, 0, 0, 32, 32); TextureRegion region2 = new TextureRegion(GdxGame.TEX_TARGET, 0, 0, 32, 32); _sprite = new Sprite(region); _sprite.setSize(.05f, .05f); _sprite_target = new Sprite(region2); _sprite_target.setSize(.1f, .1f); _max_velocity = 0.05f; _max_speed = 0.005f; _velocity = new Vector2(0, 0); _desired_velocity = new Vector2(0, 0); _steering = new Vector2(0, 0); _position = new Vector2(-_sprite.getWidth()/2, -_sprite.getHeight()/2); _mass = 10f; } public void Update(float deltaTime){ _target = new Vector2(Gdx.input.getX(), Gdx.input.getY()); _desired_velocity = ((_target.sub(_position)).nor()).scl(_max_velocity,_max_velocity); _steering = ((_desired_velocity.sub(_velocity)).limit(_max_speed)).div(_mass); _velocity = (_velocity.add(_steering)).limit(_max_speed); _position = _position.add(_velocity); _sprite.setPosition(_position.x, _position.y); _sprite_target.setPosition(Gdx.input.getX(), Gdx.input.getY()); } I've used this tutorial here. Thanks!

    Read the article

  • Virtual Machine Manager 2012 CPU Average

    - by Grant
    What exactly is the CPU Average field in VMM 2012 showing me? I'm running Server 2008 R2 with VMM 2012. My server has 2x16 core CPUs installed. An example virtual machine has 4 virtual processors, and shows 20% CPU usage. Is that: 20% of the entire system's available CPU power? 20% of 4 of the 32 core's CPU power? 20% of one core's CPU? (in which case it could go as high as 400%) Something else entirely? How can I tell how much of the entire system's CPU power is being used (all 32 cores)? Edit: Well, I can tell for sure it's not 20% of the entire system's CPU power - since the entire server's CPU averages add up to well over 100% right now.

    Read the article

  • Grub2 fails to chainload Windows 7 with error "invalid signature"

    - by atomicpirate
    I've built a new UEFI 64-bit system with both Windows 7 and Ubuntu 11.10 installed (on separate hard drives). I'd like to be able to boot Windows 7 from the grub menu, but I have so far been unsuccessful in getting grub to chainload it. After getting the grub menu, I choose the option for the command line and I can see that bootmgfw.efi is at (hd1,gpt1)/efi/Microsoft/Boot/bootmgfw.efi. However, when I attempt to chainload I get an error: grub> chainloader (hd1,gpt1)/efi/Microsoft/Boot/bootmgfw.efi error: invalid signature I am not sure whether I chose the UEFI boot option when I installed Linux from the LiveCD, and so I am wondering if the grub I have is perhaps unable to chainload in this manner? In any case I am not sure how to get the chainload to work.

    Read the article

  • LVM2 vs MDADM performance

    - by archer
    I've used MDADM + LVM2 on many boxes for quite a while. MDADM was serving for both RAID0 and RAID1 arrays, while LVM2 where used for logical volumes on top of MDADM. Recently I've found that LVM2 could be used w/o MDADM (thus minus one layer, as the result - less overhead) for both mirroring and stripping. However, some guys claims that READ PERFORMANCE on LVM2 for mirrored array is not that fast as for LVM2 (linear) on top of MDADM (RAID1) as LVM2 does not read from 2+ devices at a time, but use 2nd and higher devices in case of 1st device failure. MDADM reads from 2 devices at a time (even in mirrored mode). Who could confirm that?

    Read the article

  • Turn off the Linux OOM killer by default?

    - by Peter Eisentraut
    The OOM killer on Linux wreaks havoc with various applications every so often, and it appears that not much is really done on the kernel development side to improve this. Would it not be better, as a best practice when setting up a new server, to reverse the default on the memory overcommitting, that is, turn it off (vm.overcommit_memory=2) unless you know you want it on for your particular use? And what would those use cases be where you know you want the overcommitting on? As a bonus, since the behavior in case of vm.overcommit_memory=2 depends on vm.overcommit_ratio and swap space, what would be a good rule of thumb for sizing the latter two so that this whole setup keeps working reasonably?

    Read the article

  • Uninstall last n of ports/packages

    - by Radio
    While compiling some port, I realized that it depends on 1000+ of other ports and will install forever until I die or my disk is full (my hdd is really small). I interrupted make install clean. How do I uninstall and clean those dependencies which have already been built and installed? (there are at least 100+ of them) pkg_cutleaves wont work in this case, since the main port wasn't registered yet. Please help. FreeBSD 9.0-RELEASE amd64 EDIT: Another way to ask this question: How can I see all dependencies for a non-registered port, and all subdependencies for those dependencies, independent with previously installed ports or their [sub]dependencies?

    Read the article

  • xVelocity engines compared: VertiPaq vs ColumnStore #ssas #vertipaq #xvelocity #sql #tabular

    - by Marco Russo (SQLBI)
    During the last months I and Alberto worked in several projects using Analysis Services Tabular and we had to face real world issues, such as complex queries, large data volume, frequent data updates and so on. Sometime we faced the challenge of comparing Tabular performance with SQL Server. It seemed a non-sense, because even if the same core xVelocity technology is implemented in both products (SQL Server 2012 uses ColumnStore indexes, whereas Analysis Services 2012 uses VertiPaq), we initially assumed that the better optimization for the in-memory engine used by Analysis Services would have been always better than SQL Server. However, we discovered several important things: Processing time might be different and having data on SQL Server could make ColumnStore way faster for processing. Partitioning in SQL Server might be much more effective for query performance than Analysis Services. A single query can scale easily on more processor on SQL Server, whereas in Analysis Services the formula engine is single-threaded and could be a bottleneck for certain queries. In case of a large workload with many concurrent users, storage engine cache in Analysis Services could be a big advantage over SQL Server, especially for scalability As you can see, these considerations are not always obvious and you might be tempted to make other assumptions based on these information. Well, don’t do that. Before anything else, read the whitepaper VertiPaq vs ColumnStore Comparison written by Alberto Ferrari. Then, measure your workload. Finally, make some conclusion. But don’t make too many assumptions. You might be wrong, as we did at the beginning of this journey.

    Read the article

  • SLES 11 - ocfs2 - Locking does not appear to work

    - by Autobyte
    Hi I have two SLES 11 servers that are SAN attached to a Clarion CX-340. The SAN partition has been formatted with ocfs2 and I have both machines setup in a cluster and the cluster is running (all appears to be normal). I have a small java application as a locking test and when I run the application on both machines at the same time, I should get the lock on one server and the other should refuse the lock since the first already holds a lock on that file but in this case both servers get a lock on the same file. Basically my cluster.conf looks like this: node: ip_port = 7777 ip_address = 192.168.10.121 number = 1 name = osrsles10node1 cluster = osrsles10 node: ip_port = 7777 ip_address = 192.168.10.122 number = 2 name = osrsles10node2 cluster = osrsles10 cluster: node_count = 2 name = osrsles10 Please ask for any other info - I really need these locks to be exclusive to each server. Thanks.

    Read the article

< Previous Page | 421 422 423 424 425 426 427 428 429 430 431 432  | Next Page >