Search Results

Search found 26412 results on 1057 pages for 'product key'.

Page 471/1057 | < Previous Page | 467 468 469 470 471 472 473 474 475 476 477 478  | Next Page >

  • Wireless VGA for a projector

    - by Andrew
    I am in need of a wireless VGA suitable for around 30m range and available in Australia. Something just like IOgears GUWAVKIT http://www.iogear.com/product/GUWAVKIT/ But it needs to be available in Australia. And do the 30m range.

    Read the article

  • Acronis Disk Director AFTER Clone Disk error: PXE-E61: Media test failure, check cable

    - by Kairan
    Used Acronis Disk Director on my desktop, plugged in the laptop drive 240GB SSD (USB) and the new hard drive 500GB SSD (usb) and the copy seemed to be fine. I didnt see any error messages but I didnt stare at it for 3 hours either. The clone disk of course the Toshiba hidden restore partition, the primary partition C drive and the active (boot?) partition and yes, did check box for copy NT signature. The computer boots up fine most of the time, but it seems that when the computer goes to sleep (i believe its sleep, hard to do much testing during school) or hibernate or reboot it will sometimes display this message: Intel(R) Boot Agent GE v1.3.52 Copyright (C) 1997-2010, Intel Corporation PXE-E61: Media test failure, check cable PXE-M0F: Exiting Intel Boot Agent Insert system disk in drive. Press any key when ready... Of course any key does nothing but repeat a similar method. However, if I press the power button on the laptop (Toshiba Portege R705, Win 7 Pro 64-bit) it puts computer into hibernate. After hibernating I press power button again and it comes out of hibernation without any odd messages or problems described above... so apparently that is my TEMP fix. Another recent issue I noticed is on occasion when creating a new folder or modifying something in the system variables, other random areas I will get a message: "The Stub received bad data" and simply retry the task and it works. Perhaps these two issues are linked.

    Read the article

  • Windows 7 wireless not seeing any networks

    - by jkohlhepp
    I think I have managed to confuse Windows 7. When I did the install, I had the network cable plugged in to my router, but the wireless card was also enabled. During the install, Windows 7 seemed to see my wireless network and even asked me for the WEP key. I know that it used the WEP key because I initially entered an invalid one and it gave me an error. Then the network said "SoAndSoWireless Connected". However, when I unplug or disable my wired network card, then I have no internet, and it can't see any networks. When I plug in the wired network card, it says "SoAndSoWireless Connected". Under Network and Internet Network Connections I have "Local Area Connection" and "Wireless Network Connection". The wired one's status is "SoAndSoWireless" and the wireless status is "Not Connected". Also, the wireless connection can't seem to see any other wireless networks in the area and I know there are tons. My neighbors have several. I've somehow seemingly confused Windows 7 into thinking that my wired network card is my wireless card or something. Any ideas on how to un-confuse it? This is a desktop machine by the way, if it matters. EDIT: Ah, I think part of the problem is that I named my network accidentally the same as the name of the wireless network being broadcast by the wireless router. So that might be why it says that name on the hard-wired connection. Perhaps the drivers just are completely not working for the wireless card. Thanks, ~ Justin

    Read the article

  • Variable directory names over SCP

    - by nedm
    We have a backup routine that previously ran from one disk to another on the same server, but have recently moved the source data to a remote server and are trying to replicate the job via scp. We need to run the script on the target server, and we've set up key-based scp (no username/password required) between the two servers. Using scp to copy specific files and directories works perfectly: scp -r -p -B [email protected]:/mnt/disk1/bsource/filename.txt /mnt/disk2/btarget/ However, our previous routine iterates through directories on the source disk to determine which files to copy, then runs them individually through gpg encryption. Is there any way to do this only by using scp? Again, this script needs to run from the target server, and the user the job runs under only has scp (no ssh) access to the target system. The old job would look something like this: #Change to source dir cd /mnt/disk1 #Create variable to store # directories named by date YYYYMMDD j="20000101/" #Iterate though directories in the current dir # to get the most recent folder name for i in $(ls -d */); do if [ "$j" \< "$i" ]; then j=${i%/*} fi done #Encrypt individual files from $j to target directory cd ./${j%%}/bsource/ for k in $(ls -p | grep -v /$); do sudo /usr/bin/gpg -e -r "Backup Key" --batch --no-tty -o "/mnt/disk2/btarget/$k.gpg" "$/mnt/disk1/$j/bsource/$k" done Can anyone suggest how to do this via scp from the target system? Thanks in advance.

    Read the article

  • How to tackle dell support system? [closed]

    - by Nishant Kumar
    We have purchased a Dell Optiplex 9010 SSFV for our organization's work. Since the first installation two of the USB keyboard keys were not working properly. I had to press those keys two times simultaneously, on first time keys did not work and for for second time it printed two characters (as it were buffering first character.) Two keys that were not working properly: Hexangrave (Below the ESC key: `) Double Quotes (Left the enter key ") We registered our complaint with DELL and they suggested (with some hard to understand and weird ENGLISH accent) some test and tricks, such as switching to different ports, checking keyboard on different PC, and it worked well with diff. PC(with Windows 7 Home Premium installed). It was clear that it is an OS fault, hence they suggested to re-install OS. Problem began here, we have a project on the run and currently a video editing project setup on our system, so can't re-install system in hurry and also DELL persons were not providing any other solution such as updating keyboard driver, etc. Arguments I am a Software Engg. and don't think it is a feasible solution to re-install entire system for simple problems. This prob is coming since the fresh system installation, so I don't think it will solve the problem. Finally, I had to find solution myself and got it here, now I want to show my disappointment to dell persons or at least tell them that they should improve there support system to not advice to re-install entire system for that simple problems. Notes We have purchased 5 years NEXT business day support from DELL for around 8000 INR (Not for that kind of solutions from DELL). So can anyone tell me how to tackle dell support system officially, so that they will pay more attention in near future. Thanks

    Read the article

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • SQL Full-Text indexing not populating

    - by Sam
    Hi, We installed a clustered SQL 2005 installation on windows 2008 and reattached our san drives from another machine and restored to do a migration to new hardware. There have been a few minor issues, but this one has me stuck. Trying to populate Full-Text indexes is not working. I create a basic table with some simple text in a new database and get the same results as old indexes. 2010-09-27 10:30:46.85 spid19s Informational: Full-text Full population initialized for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'). Population sub-tasks: 1. 2010-09-27 10:31:15.36 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001DF. Attempt will be made to reindex it. 2010-09-27 10:31:15.37 spid19s The component 'MSFTE.DLL' reported error while indexing. Component path 'D:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Binn\MSFTE.DLL'. 2010-09-27 10:31:15.37 spid19s Error '0x80070003' occurred during full-text index population for table or indexed view '[SQL_DBA].[dbo].[CIS_Report_Executions]' (table or indexed view ID '1767677345', database ID '5'), full-text key value 0x000001E0. Attempt will be made to reindex it. The rebuild/repopulate procedure finishes, but I get zero rows in the index. The .dll in the message is present and the service accounts have access to this. My FTData also has data in it, so it seems there wouldn't be permission issue on this folder. Application throws this error: “PHP Warning: mssql_query() [function.mssql-query]: message: Full-text catalog 'ikm_PageIndex_FText' is in an unusable state. Drop and re-create this full-text catalog. (severity 16) in E:\Inetpub\knowledgebase_insidemesa\lib\database\mssql.php on line 154” A microsoft discussion is the only post I found which had claimed to fix this - said it was registry related, but then didn't post the fix.

    Read the article

  • Shows error message "ialmrnt 5 display driver stooped working".

    - by user68705
    when ever i play movie with high resolution(720hz) My Destop PC shows a black screen and after a while shows message "ialmrnt 5 display driver stooped working". and i am having the following configuration 1GB RAM DDR1 windows xp OS processor- Intel Pentium 4 Processor Srm-Motherboard Graphics Driver Product Detected -Intel® 845G Current Driver Installed-6.14.10.3889 Intel Chipset Software Installation Utility (Chipset INF) - Current Version Installed 9.1.0.1012 kindly help me to fix this problem

    Read the article

  • Helicon ISAPI_REWRITE 3 - Not Logging Anything

    - by Brian
    Hello, The ISAPI_REWRITE Helicon product does not log anything... I setup logging to run as: [ISAPI_Rewrite] RewriteEngine on #enabling rewrite.log RewriteLogLevel 9 #enabling error.log LogLevel debug But nothing is getting logged. Is it something I'm doing, is it working? It is installed, it's given high priority in IIS (do see it visibly present). Any ideas why it isn't logging? Should it log even if not rewriting?

    Read the article

  • "Bug code usb driver" blue screen in windows

    - by trinity
    Hi all, I have dual OS ( Fedora and windows xp ). for the past two months when i use windows xp, i'm frequently getting a blue screen with msg : " bug code usb driver ".Not knowing what to do next , i switch off the system and reboot it. Can anyone help me understand why this is happening , and how to troubleshoot this problem.. Here's the info provided about this problem after system restarts : BCCode : fe BCP1 : 00000004 BCP2 : 88F3BA08 BCP3 : 88E9FB10 BCP4 : 00000000 OSVer : 5_1_2600 SP : 2_0 Product : 256_1

    Read the article

  • I/O intensive MySql server on Amazon AWS

    - by rhossi
    We recently moved from a traditional Data Center to cloud computing on AWS. We are developing a product in partnership with another company, and we need to create a database server for the product we'll release. I have been using Amazon Web Services for the past 3 years, but this is the first time I received a spec with this very specific hardware configuration. I know there are trade-offs and that real hardware will always be faster than virtual machines, and knowing that fact forehand, what would you recommend? 1) Amazon EC2? 2) Amazon RDS? 3) Something else? 4) Forget it baby, stick to the real hardware Here is the hardware requirements This server will be focused on I/O and MySQL for the statistics, memory size and disk space for the images hosting. Server 1 I/O The very main part on this server will be I/O processing, FusionIO cards have proven themselves extremely efficient, this is currently the best you can have in this domain. o Fusion ioDrive2 MLC 365GB (http://www.fusionio.com/load/-media-/1m66wu/docsLibrary/FIO_ioDrive2_Datasheet.pdf) CPU MySQL will use less CPU cores than Apache but it will use them very hard, the E7 family has 30M Cache L3 wichi provide boost performance : o 1x Intel E7-2870 will be ok. Storage SAS will be good enough in terms of performance, especially considering the space required. o RAID 10 of 4 x SAS 10k or 15k for a total available space of 512 GB. Memory o 64 GB minimum is required on this server considering the size of the statistics database. Warning: the statistics database will grow quickly, if possible consider starting with 128 GB directly, it will help. This server will be focused on I/O and MySQL for the statistics, memory size and disk space for the images hosting. Server 2 I/O The very main part on this server will be I/O processing, FusionIO cards have proven themselves extremely efficient, this is currently the best you can have in this domain. o Fusion ioDrive2 MLC 365GB (http://www.fusionio.com/load/-media-/1m66wu/docsLibrary/FIO_ioDrive2_Datasheet.pdf) CPU MySQL will use less CPU cores than Apache but it will use them very hard, the E7 family has 30M Cache L3 wichi provide boost performance : o 1x Intel E7-2870 will be ok. Storage SAS will be good enough in terms of performance, especially considering the space required. o RAID 10 of 4 x SAS 10k or 15k for a total available space of 512 GB. Memory o 64 GB minimum is required on this server considering the size of the statistics database. Warning: the statistics database will grow quickly, if possible consider starting with 128 GB directly, it will help. Thanks in advance. Best,

    Read the article

  • apache name virtual host - two domains and SSL

    - by Tom
    I'm trying to setup Apache(2.2.3) to run two websites with SSL using both different domains and IP addresses. Both websites run fine on port 80 but when I tried to enable SSL for website2 I get a ssl_error_bad_cert_domain error; website2 picks up the SSL cert for website1. Here is my setup in httpd.conf: # Website1 NameVirtualHost 192.168.10.1:80 <VirtualHost 192.168.10.1:80> DocumentRoot /var/www/html ServerName www.website1.org </VirtualHost> NameVirtualHost 192.168.10.1:443 <VirtualHost 192.168.10.1:443> SSLEngine On SSLCertificateFile conf/ssl/website1.cer SSLCertificateKeyFile conf/ssl/website1.key </VirtualHost> # Website2 NameVirtualHost 192.168.10.2:80 <VirtualHost 192.168.10.2:80> DocumentRoot /var/www/html/chart ServerName www.website2.org </VirtualHost> NameVirtualHost 192.168.10.2:443 <VirtualHost 192.168.10.2:443> SSLEngine On SSLCertificateFile conf/ssl/website2.cer SSLCertificateKeyFile conf/ssl/website2.key </VirtualHost> Update: In answer to Shane (this wouldn't fit in comment box) here is the output from apachectl -S: VirtualHost configuration: 192.168.10.2:80 is a NameVirtualHost default server www.website2.org (/etc/httpd/conf/httpd.conf:1033) port 80 namevhost www.website2.org (/etc/httpd/conf/httpd.conf:1033) 192.168.10.2:443 is a NameVirtualHost default server bogus_host_without_reverse_dns (/etc/httpd/conf/httpd.conf:1040) port 443 namevhost bogus_host_without_reverse_dns (/etc/httpd/conf/httpd.conf:1040) 192.168.10.1:80 is a NameVirtualHost default server www.website1.org (/etc/httpd/conf/httpd.conf:1017) port 80 namevhost www.website1.org (/etc/httpd/conf/httpd.conf:1017) 192.168.10.1:443 is a NameVirtualHost default server bogus_host_without_reverse_dns (/etc/httpd/conf/httpd.conf:1024) port 443 namevhost bogus_host_without_reverse_dns (/etc/httpd/conf/httpd.conf:1024) wildcard NameVirtualHosts and _default_ servers: _default_:443 192.168.10.1 (/etc/httpd/conf.d/ssl.conf:81) Syntax OK

    Read the article

  • Kerberos service on win2k dc will not start following disk failure

    - by iwilson68
    Hi, I have a win2k (mixed mode domain) with 4 DCS. One of these also acts an exchange 2000 server which uses 2 logical volumes from an MSA 2000 array. AD etc is stored on local drives. We experienced a problem last week when the raid array fell back to a redundant controller and this temporarily meant that the two logical drives were not visible to the server for around 5 minutes and a couple of reboots. The log records these Events as Type: Warning Event Source: Disk Event Category: None Event ID: 51 Date: 06/11/2009 Time: 11:46:23 User: N/A Computer: server1 Description: An error was detected on device \Device\Harddisk1\DR1 during a paging operation. Following these problems, the server “kerberos Key Distribution” service refuses to start with an “error.31 a device attached to the system is not functioning”. All other automatic start services (including net logon) are running and there are no DNS issues etc. All devices are also functioning but the two logical MSA disks are now numbered in the Windows Disk Management MMC as 2 and 4 and I suspect that they may have previously been identified as disks 1 & 2 and perhaps windows still sees this as an ongoing failure?? Replication has not been affected but obviously there are many audit failures in the security log relating to users and workstations presumably linked to the Kerberos issue. Attempting to manually start the kerberos service generates the following in the System Log. Event Type: Error Event Source: Service Control Manager Event Category: None Event ID: 7023 Date: 09/11/2009 Time: 09:46:55 User: N/A Computer: Server1 Description: The Kerberos Key Distribution Center service terminated with the following error: A device attached to the system is not functioning. DCDIAG passes all tests except “Advertising” and “Services” which I believe relate directly to the failure of Kerberos only. Any advice would be appreciated.

    Read the article

  • Apache apachectl/httpd hangs

    - by VANJ
    Oracle HTTP Server (OHS), RHEL 5.3, Dell hardware Oracle has a modified version of Apache2 for use with web-enabled components in its product suite. The apachectl start command just hangs, even configtest hangs! Not sure what it is waiting for. How does one go about troubleshooting this? Thanks

    Read the article

  • check_snmp with snmpv3 protocol giving "Unkown Report message" error

    - by John
    I'm trying to add a nagios command to use snmpv3 for monitoring printer status messages. When using the check_snmp command, I get the following error: External command error: snmpget: Unknown Report message Here is the command I'm typing in: ./check_snmp -P 3 -H <hostname> -L authPriv -U snmpuser -A snmppassword -X snmppassword -o 1.3.6.1.4.1.11.2.4.3.1.2.0 -C public -d "STRING:" -a MD5 These values for auth key, private key, username, etc all work when using snmpwalk. Can someone enlighten me as to what that error message really means? EDIT: It looks like check_snmp isn't taking my v3 credentials when passing over to snmpget. Here is my input with the verbose option: ./check_snmp -H <hostname> -o 1.3.6.1.2.1.2.2.1.10.1 -C public -m ALL -P 3 -L authPriv -U snmpuser -a MD5 -A snmppassword -x DES -X snmppassword -v And here is the output: /usr/bin/snmpget -t 1 -r 5 -m ALL -v 3 [authpriv] <hostname>:161 1.3.6.1.2.1.2.2.1.10.1 External command error: snmpget: Unknown Report message So I guess now my question would be: why isn't check_snmp passing all the commandline options to snmpget?

    Read the article

  • How to remove iso 9660 from USB?

    - by a_m0d
    I have somehow managed to write an iso 9660 image onto my USB drive, which makes all my computer think that the device is actually a CD. I have tried various methods of removing this partition, but nothing seems to work. I have tried fdisk, which says $ fdisk -l /dev/sdb Cannot open /dev/sdb parted crashes when I try to use it on this device. I have even tried $ dd if=/dev/zero of=/dev/sdb but it just hangs with no output (either on screen or on disk). However, when I plug the USB in, it does mount, and I can view (but not edit) the files on it. edit: now the result is $ dd if=/dev/zero of=/dev/sdb dd: opening `/dev/sdb': Read-only file system I have also tried re-formatting it on Windows, but it gets to the end of the format process and then says "Couldn't format the drive". How can I remove this partition and get my whole USB drive back to normal again? EDIT 1: Trying a simple mkfs doesn't work: $ sudo mkfs -t vfat /dev/sdb mkfs.vfat 3.0.0 (28 Sep 2008) mkfs.vfat: Will not try to make filesystem on full-disk device '/dev/sdb' (use -I if wanted) I can't do mkfs on /dev/sdb1 because there is no such partition, as shown:$ ls /dev | grep sdb sdb EDIT 2: This is the information posted by dmesg when I plug the device in:$ dmesg . . (snip) . usb 2-1: New USB device found, idVendor=058f, idProduct=6387 usb 2-1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 usb 2-1: Product: Mass Storage usb 2-1: Manufacturer: Generic usb 2-1: SerialNumber: G0905000000000010885 usb-storage: device found at 4 usb-storage: waiting for device to settle before scanning usb-storage: device scan complete scsi 6:0:0:0: Direct-Access FLASH Drive AU_USB20 8.07 PQ: 0 ANSI: 2 sd 6:0:0:0: [sdb] 4069376 512-byte hardware sectors (2084 MB) sd 6:0:0:0: [sdb] Write Protect is off sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 sd 6:0:0:0: [sdb] Assuming drive cache: write through sd 6:0:0:0: [sdb] 4069376 512-byte hardware sectors (2084 MB) sd 6:0:0:0: [sdb] Write Protect is off sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 sd 6:0:0:0: [sdb] Assuming drive cache: write through sdb: unknown partition table sd 6:0:0:0: [sdb] Attached SCSI removable disk sd 6:0:0:0: Attached scsi generic sg2 type 0 ISO 9660 Extensions: Microsoft Joliet Level 3 ISO 9660 Extensions: RRIP_1991A SELinux: initialized (dev sdb, type iso9660), uses genfs_contexts CE: hpet increasing min_delta_ns to 15000 nsec This shows that the device is formatted as ISO 9660 and that it is /dev/sdb. EDIT 3: This is the message that I find at the bottom of dmesg after running cfdisk and writing a new partition table to the disk:SELinux: initialized (dev sdb, type iso9660), uses genfs_contexts sd 17:0:0:0: [sdb] Device not ready: Sense Key : Not Ready [current] sd 17:0:0:0: [sdb] Device not ready: < ASC=0xff ASCQ=0xffASC=0xff < ASCQ=0xff end_request: I/O error, dev sdb, sector 0 Buffer I/O error on device sdb, logical block 0 lost page write due to I/O error on sdb

    Read the article

  • Slow INFORMATION_SCHEMA query

    - by Thomas
    We have a .NET Windows application that runs the following query on login to get some information about the database: SELECT t.TABLE_NAME, ISNULL(pk_ccu.COLUMN_NAME,'') PK, ISNULL(fk_ccu.COLUMN_NAME,'') FK FROM INFORMATION_SCHEMA.TABLES t LEFT JOIN INFORMATION_SCHEMA.TABLE_CONSTRAINTS pk_tc ON pk_tc.TABLE_NAME = t.TABLE_NAME AND pk_tc.CONSTRAINT_TYPE = 'PRIMARY KEY' LEFT JOIN INFORMATION_SCHEMA.CONSTRAINT_COLUMN_USAGE pk_ccu ON pk_ccu.CONSTRAINT_NAME = pk_tc.CONSTRAINT_NAME LEFT JOIN INFORMATION_SCHEMA.TABLE_CONSTRAINTS fk_tc ON fk_tc.TABLE_NAME = t.TABLE_NAME AND fk_tc.CONSTRAINT_TYPE = 'FOREIGN KEY' LEFT JOIN INFORMATION_SCHEMA.CONSTRAINT_COLUMN_USAGE fk_ccu ON fk_ccu.CONSTRAINT_NAME = fk_tc.CONSTRAINT_NAME Usually this runs in a couple seconds, but on one server running SQL Server 2000, it is taking over four minutes to run. I ran it with the execution plan enabled, and the results are huge, but this part caught my eye (it won't let me post an image): http://img35.imageshack.us/i/plank.png/ I then updated the statistics on all of the tables that were mentioned in the execution plan: update statistics sysobjects update statistics syscolumns update statistics systypes update statistics master..spt_values update statistics sysreferences But that didn't help. The index tuning wizard doesn't help either, because it doesn't let me select system tables. There is nothing else running on this server, so nothing else could be slowing it down. What else can I do to diagnose or fix the problem on that server?

    Read the article

  • BIOS corrupted? How to proceed? Acer Travelmate 290

    - by dtlussier
    I have a older ACER Travelmate 290 (manufactured in 2002 or 2003), which I recently tried to upgrade to Ubuntu 9.10. After doing the upgrade process it appeared as if I had a problem with my x server configuration, as on the first reboot post-install I heard the Ubuntu startup sound, but had a black screen. I thought I would then reboot again to drop down into text-mode to trouble shoot the x configuration problem. However, when I tried rebooting, something went wrong and since then when I start up the machine I get absolutely nothing except the first hardware check (i.e. HDD light flashes, CD/DVD drive spins, etc.). Other than that the screen remains totally black and I have no HDD or processor activity at all. I have tried restarting it a number of time holding down all kinds of key combinations to try and coax it into the BIOS (if possible) with no luck. I have also tried putting in both a live Linux disc and a Windows install disk without any luck. With a disk in the drive it will spin for a few seconds and then stop. All this has lead me to suspect that the BIOS is somehow corrupt (not sure about the right terminology). I have tried putting a new BIOS image and installer program downloaded from ACER on a USB key to see if it will run when I start up the machine, but no luck. I'm not sure if this method of interacting/updating/flashing the BIOS will work outside of Windows/DOS as both OSs are mentioned kind of ambiguously in the documentation. I have also taken the laptop case apart and inspected the various cards and cannot find any obviously burned out components. I'm not sure how to proceed at this point in terms of components to try, or how to try and load a new BIOS image onto the board. Any advice here would be great, especially from those with experience with this particular line of laptops. Thanks!

    Read the article

  • How can I manage AWS VPC ssh access accounts and keys across multiple instances?

    - by deitch
    I am setting up a standard AWS VPC structure: a public subnet some private subnets, hosts on each, ELB, etc. Operational network access will be via either an ssh bastion host or an openvpn instance. Once on the network (bastion or openvpn), admins use ssh to access the individual instances. From what I can tell all of the docs seem to depend on a single user with sudo rights and a single public ssh key. But is that really best practice? Isn't it much better to have each user access each host under their own name? So I can deploy accounts and ssh public keys to each server, but that rapidly gets unmanageable. How do people recommend managing user accounts? I've looked at: IAM: It doesn't like like IAM has a method for automatically distributing accounts and ssh keys to VPC instances. IAM via LDAP: IAM doesn't have an LDAP API LDAP: set up my own LDAP servers (redundant, of course). Bit of a pain to manage, still better than managing on every host, especially as we grow. Shared ssh key: rely on the VPN/bastion to track user activities. I don't love it, but... What do people recommend? NOTE: I moved this over from accidentally posting in StackOverflow.

    Read the article

  • Anything such as a usb laptop charger?

    - by iNinja
    I am looking for a laptop charger that requires no power outlet but instead utilizes a usb port of another computer to charge my laptop. That is, I am seeking a usb-to-laptop port charger, NOT power outlet-to-laptop's usb charger. Is such a product even possible? I am guessing no since the usb port would not be able to supply enough electricity to power the laptop, even to maintain the battery (not charge it).

    Read the article

< Previous Page | 467 468 469 470 471 472 473 474 475 476 477 478  | Next Page >