Search Results

Search found 41660 results on 1667 pages for 'mike two'.

Page 479/1667 | < Previous Page | 475 476 477 478 479 480 481 482 483 484 485 486  | Next Page >

  • Performance degrades for more than 2 threads on Xeon X5355

    - by zoolii
    Hi All, I am writing an application using boost threads and using boost barriers to synchronize the threads. I have two machines to test the application. Machine 1 is a core2 duo (T8300) cpu machine (windows XP professional - 4GB RAM) where I am getting following performance figures : Number of threads :1 , TPS :21 Number of threads :2 , TPS :35 (66 % improvement) further increase in number of threads decreases the TPS but that is understandable as the machine has only two cores. Machine 2 is a 2 quad core ( Xeon X5355) cpu machine (windows 2003 server with 4GB RAM) and has 8 effective cores. Number of threads :1 , TPS :21 Number of threads :2 , TPS :27 (28 % improvement) Number of threads :4 , TPS :25 Number of threads :8 , TPS :24 As you can see, performance is degrading after 2 threads (though it has 8 cores). If the program has some bottle neck , then for 2 thread also it should have degraded. Any idea? , Explanations ? , Does the OS has some role in performance ? - It seems like the Core2duo (2.4GHz) scales better than Xeon X5355 (2.66GHz) though it has better clock speed. Thank you -Zoolii

    Read the article

  • ProCurve ACL to prevent a subnet from leaving the switch

    - by kce
    I have a single HP ProCurve 2610 in a remote location that is connected in with the rest of the network via SHDSL. There are two Layer-3 networks on this segment. ACLs are setup to deny one subnet (192.0.2.0/24) from ever being able to leave the switch by virtue of being applied to port attached to the upstream connection. The other subnet should be permitted to freely leave the switch. Both subnets are on the same VLAN. Unfortunately SFlow very clearly show broadcast traffic from 192.0.2.0/24 on the upstream connection. ProCurve ACLs are not my strong suit but I feel like I'm missing something very simple here. ip access-list extended "Filter for Camera Network" deny ip 192.0.2.0 0.0.0.255 0.0.0.0 255.255.255.255 log permit ip 0.0.0.0 255.255.255.255 0.0.0.0 255.255.255.255 exit interface 24 name "DSL - UPLINK" access-group "Filter for Camera Network" in exit Unless I am mistaken traffic from 192.0.2.0/24 should be dropped as it crosses the uplink port (int 24) whereas all other traffic will be permited by the following default allow rule. What exactly am I missing here? EDIT: Firstly, why do you have two subnets contained in the same VLAN? Because that's how it was configured by a previous administrator and while it makes conceptual sense that a single subnet is "mapped" to a single VLAN there's no technical constraint that I am aware of that makes this have to be the case. Instead of filtering inbound traffic on your uplink, you should be filtering outbound traffic. The HP2600 series can only filter inbound traffic on interfaces. Should I change my filter to deny any to 192.0.2.0/24?

    Read the article

  • How to correctly configure DNS for Icelandic domains and Plesk

    - by Leonard Challis
    I have a domain registered with ISNIC (domain.is). They only let you set nameservers that pass their requirements. I've been told it's this requirement that I need to fix: Nameserver must be consistently registered in DNS, i.e. its own A resource record must be available and a corresponding PTR resource record as well. I allocated two new IP addresses from my server host and at that point set their PTR records to ns0.domain.is and ns1.domain.is. After that I created two A records for that domain in Plesk, again ns0. and ns2.domain.is with their respective IPs. Next, I went to the ISNIC page to register my nameservers, along with their IP addresses I'd allocated and this worked perfectly for both without error. So the final job was to set the nameservers for the domain via ISNIC's control panel, however when I try, I'm getting this error: Test results for "NS0.DOMAIN.IS": The nameserver ns1.vps123.vpsprovider.com is not consistently registered in DNS (ns1.vps123.vpsprovider.com => 1123.123.123.123 => vps123.vpsprovider.com) The nameserver ns0.vps123.vpsprovider.com is not consistently registered in DNS (ns0.vps123.vpsprovider.com => 1123.123.123.123 => vps123.vpsprovider.com) The nameserver ns0.DOMAIN.IS is missing from the NS record set for DOMAIN.IS Test results for "NS1.DOMAIN.IS": The nameserver ns1.DOMAIN.IS is missing from the NS record set for DOMAIN.IS The nameserver ns0.DOMAIN.IS is missing from the NS record set for DOMAIN.IS This is really at the limits of my DNS knowledge I'm afraid. It feels like I'm close but maybe missing a vital part, linking the nameservers in Plesk or something?

    Read the article

  • How to create Windows Vista/Windows 7 Startup disk or Rescue disk or system restore points on a CD?

    - by goldenmean
    Hello, I have two laptops, one having Windows-Vista home premium and other one having Windows-7 professional. Both versions of OS are OEM installs(pre-installed when I bought the laptop) and I do not have the Windows Installation disks for them. usually the installation disks provide a repair option in case one needs to repair/rescue a improper windows installation. But since I dont have the installation disks, I want to create rescue disks/startup disks for these. My questions are : 1] How to create a system rescue disk/startup disk on a CD from these two versions of Windows? 2] Doesn't the system restore points which Vista/Windows-7 create, cannot be created on a CD disk instead of hard-disk? 3] If I have a manual backup of my windows registry, in which I have exported all the registry to a file and I have that file on a CD, how to restore that registry back to the windows installation which might not be booting up properly due to bad registry problem. EDIT: 4]Is there any way to use these system restore points directly during bootup of the laptop, if windows does cannot boot properly due to problem. First laptop is HP Pavillion dv6646 and second one is Sony VAIO VCPEE series. thank you. -AD

    Read the article

  • Windows VPN for remote site connection drawbacks

    - by Damo
    I'm looking for some thoughts on a particular way of setting up a estate of machines. We have a requirement to install machines into unmanned, remote locations. These machines will auto login and perform tasks controlled from a central server. In order to manage patching, AV, updates etc I want these machines to be joined to a dedicated domain for this estate. Some of the locations will only have 3G connectivity (via other hardware), others will be located on customer premises in internal networks. The central server (of ours) and the Domain Controller will be on a public WAN. I see two ways of facilitating this. Install a router at each location and have a site to site VPN between the remove device and the data centre where the servers are location Have the remote machine dial up and authenticate via a Windows VPN connection to the DC via RAS Option one is more costly to setup and has a higher operational cost. It also offers better diagnostics if the remote PC goes down. Option two works well but is solely dependent on the VPN connection been made before any communication can be made to the remote machine. In a simple test, I can got a Windows 7 machine to dial a VPN prior to authentication to a domain, then automatically login to the machine using domain credentials. If the VPN connection drops, it redials. I can also create a timed task to auto connect every hour in case of other issues. I'd like to know, why (if at all) is operating a remote network of devices which are located in various out of band locations in this way a bad idea? Consider 300-400 remote machines all at different sites. I'd rather have 400 VPN connections to a 2008 server than 400 routers, however I'd like to know other opinions on this.

    Read the article

  • Problems using InfraRecorder to back up ISOs of certain CDs

    - by Voyagerfan5761
    I've gotten into the habit of backing up my CDs as ISO files, just in case the discs should be damanged, lost, or destroyed. Using InfraRecorder, the process is pretty painless. Unfortunately, I have run into at least two discs that don't back up. I get the error message: Can't read source disc. Retrying from sector 252270 Sometimes this will appear repeatedly. One of the discs is my retail copy of Star Trek: Armada II; the other is disc one of DOOM 3. Both discs run flawlessly when I put them in the drive and let Windows AutoPlay them. Armada II appears as two tracks (one data, one audio) in InfraRecorder, and the error happens at the approximate track boundary. DOOM 3's first disc, however, fails much sooner (around sector 990) and appears as one solid data track. Am I simply using the wrong tools for this job? InfraRecorder is a nice free tool that I can run from my flash drive and use for most tasks of this type, but it does seem to have trouble with certain things. Ideally I'd like to hear about any workarounds people have found for this issue, but if I must switch tools I'm open to it (preferably other free tools).

    Read the article

  • Possible boot conflict?

    - by Evan Kroske
    I was installing Ubuntu on a computer on which Windows XP was already installed. The computer has multiple hard drive bays, so I decided to remove the XP HDD and install Ubuntu on a blank HDD when it was the only HDD in the system. Unfortunately, if I now try to boot Ubuntu with the Windows XP drive in the second slot, nothing will boot. However, if Windows XP is in the first slot, it will boot fine. Can anybody explain why this happens? When I was checking out the BIOS to see if something was messed up, I discovered that when Ubuntu is in the first slot, the BIOS doesn't recognize any HDDs. However, if XP is in the first slot, the BIOS recognizes both drives. Any hypotheses about why this happens? Edit: Here's the setup. I have an old server with seven SCSI HDD slots. I have five identical 68 Gb SCSI drives, but I can keep only two plugged in. XP is still installed on the first drive, but I reinstalled Ubuntu on the second drive and had Grub overwrite the XP bootloader on the first drive. Now, the setup works fine, and I can use Grub to load either XP or Ubuntu. However, if I plug in another identical blank HDD in the third slot, the computer recognizes only the XP drive and doesn't boot. Grub starts to load, then gives me a "disk not found" error. Running ls from the grub rescue prompt only shows one drive with two partitions. I guess this is a BIOS problem, but I'd still like to know what triggers it. What about a blank drive could cause the BIOS to freak out?

    Read the article

  • FTP issues with Windows 2003 box and Filezilla

    - by vanhornRF
    We've set up a Windows 2003 server with IIS 6 and the FTP is Filezilla. I'm not a sys admin by any means and neither is my other developer. I'm trying to connect to FTP on a Mac with a Cyberduck FTP client. I'm running OSX 10.6.3. The problem is that I can connect to the FTP address, but when I do it will hang for a minute or two trying to list the directories. This address is pointed to the webroot folder so it's only trying to list the pertinent folders for the site we're working on. Eventually after a minute or two it will go through and list everything and then if you try and open a file or another folder, it will hang again and then eventually list the folders. My question: Is there some stupid default setting we're missing? Is this a common occurrence? Like I said I'm not a sys admin at all and I'm sure I'm missing some valuable questions for anyone that reads this, so please fire away if you can help and you need more info, I'll do my best to provide it. Thanks!

    Read the article

  • Multiple *NIX Accounts with Identical UID

    - by Tim
    I am curious whether there is a standard expected behavior and whether it is considered bad practice when creating more than one account on Linux/Unix that have the same UID. I've done some testing on RHEL5 with this and it behaved as I expected, but I don't know if I'm tempting fate using this trick. As an example, let's say I have two accounts with the same IDs: a1:$1$4zIl1:5000:5000::/home/a1:/bin/bash a2:$1$bmh92:5000:5000::/home/a2:/bin/bash What this means is: I can log in to each account using its own password. Files I create will have the same UID. Tools such as "ls -l" will list the UID as the first entry in the file (a1 in this case). I avoid any permissions or ownership problems between the two accounts because they are really the same user. I get login auditing for each account, so I have better granularity into tracking what is happening on the system. So my questions are: Is this ability designed or is it just the way it happens to work? Is this going to be consistent across *nix variants? Is this accepted practice? Are there unintended consequences to this practice? Note, the idea here is to use this for system accounts and not normal user accounts.

    Read the article

  • KVM and libvirt: How to configure a new disc device to an existing VM?

    - by initall
    I've got an Ubuntu 9.04 server running two VM's. In /etc/libvirt/qemu/machine1.xml two disk devices are defined like this: <devices> <emulator>/usr/bin/kvm</emulator> <disk type='file' device='disk'> <source file='/vserver/machine1/disk0.qcow2'/> <target dev='hda' bus='ide'/> </disk> <disk type='file' device='disk'> <source file='/vserver/machine1/disk1.qcow2'/> <target dev='hdb' bus='ide'/> </disk> I need more storage space in at least one of the devices and thought about adding a third hdc device by simply adding one with same style as above and re-organising my mount structure (The virtual sizes of the current qcow2 files are unfortunately limited.) My problem is that reloading libvirtd and restarting the VM do not result in a new visible device (checked with fdisk). I'm aware of extending an existing qcow2 file (converting to raw format, cat-ing/adding the new one, using smth. like gparted) - but only as a last resort. Hopefully it's something very simple I'm missing?

    Read the article

  • Creating Routes using the second NIC in the box

    - by Aditya Sehgal
    OS: Linux I need some advice on how to set up the routing table. I have a box with two physical NIC cards eth0 & eth1 with two associated IPs IP1 & IP2 (both of the same subnet). I need to setup a route which will force all messages from IP1 towards IP3 (of the same subnet) to go via IP2. I have a raw socket capture program listening on IP2 (This is not for malicious use). I have set up the routing table as Destination Gateway Genmask Flags Metric Ref Use Iface IP3 IP2 255.255.255.255 UGH 0 0 0 eth1 If I try to specify eth0 while adding the above rule, I get an error "SIOCADDRT: Network is unreachable". I understand from the manpage of route that if the GW specified is a local interface, then that would be use as the outgoing interface. After setting up this rule, if i do a traceroute (-i eth0), the packet goes first to the default gateway and then to IP3. How do I force the packet originating from eth0 towards IP3 to first come to IP2. I cannot make changes to the routing table of the gateway. Please suggest.

    Read the article

  • SSH attack CentOS Amazon EC2

    - by user37143
    Hi, I run a few Rightscale CentOS AMI based instances on Amazon EC2. Two months back I found that our SSHD security is compromised( I had added host.allow and host.deny for ssh). So I created new instances and done an IP based ssh that allows only our IPs through AWS Firewall(ec2-authorize) and chnaged the ssh 22 default port to some other port but two days back I found I was not able to login to the server and when I tried on 22 port the ssh got connected and I found that sshd_conf was changed and when I tried to edit sshd_config I found root had no write permission on the file. So I tried a chmod and it said access denied for 'root' user. This is very strange. I checked secure log and history and found nothing informative. I have PHP, Ruby On Rails, Java, Wordpress apps running on these server. This time I did a chkrootkit scan and found nothing. I renamed the /etc/ssh folder and reinstalled openssh through yum. I had faced this on 3 instances on CentOS(5.2, 5.4) I have instances on Debian as well those working fine. Is this a CentOS/Rightscale issue. Guys, what security measures I should take to prevent this. Please support me this is very critical. Thanks

    Read the article

  • Archive Manager, SQL 2005 and MaxTokenSize high CPU

    - by Tim Alexander
    So, I posted this question a few days ago: Impact of increasing the MaxTokenSize for Kerberos Tickets Since then the thought was to test our settings on two member servers, one with IIS and one without. I setup two GPOs to configure the MaxTokenSize reg setting to 48000 and MaxFieldLength/MaxRequestBytes to 64200 (based on MS KB2020943, these are set at 4/3 * T + 200). The member server seemed to work ok (a devalued tape backup server). The IIS server however has had some strange repercussions. The IIS Sserver host Quest Software Archive Manager (AM) 4.5 that communicates with SQL Server 2005 Enterprise on Server 2003 R2. After the changes all looked good until the SQL Server hit 100% CPU. I have removed the GPOS, removed the reg values and even replaced them with defaults (12000 for token size and can't remember the other one but was in a blog post about the issue in my other post). No change. Bouncing the IIS Server stops the high CPU and a colleague has looked at the SQL server and it is definitely the AM connection taking up the time/work on the SQL server. I haven't changed the reg values on the SQL server or the DCs but am reluctant to do so without understanding why this has happened. I am guessing its to do with the overriding auth and group issue we have but I am not seeing Kerberos errors in either event log. Has anyone seen something similar or does anyone have some tips? Was definitely blindsided by the Kerberos issue and am swimming against the tide to keep things functioning.

    Read the article

  • Weird PCI bug: lots of missed packets, or data comes in "bursts"

    - by Thomas O
    I have an ABIT KN9 motherboard. It has one PCI-e x16 slot, three PCI-e x4 slots and two legacy PCI. My problem is with the legacy PCI (which I shall just call "PCI".) I currently have an Nvidia GeForce 8600 GT (a low end card) installed in the x16 slot and a TV card in PCI #1; the x4 slots are unused, as is PCI #2. I plan to upgrade the graphics card soon, the current card was spare. I sometimes install a USB expander in PCI #2 but it causes a lot of problems - see below. The problem is under Linux (Ubuntu 10.10, Linux 2.6.35-22-generic), but probably under all operating systems (I have not yet been able to test Windows, but I suspect it will do the same as the problems occur on the BIOS/POST side too, e.g. when using a USB keyboard on the expander the keyboard will not work at all) PCI has an enourmous delay, and packets arrive in large chunks. For example, when using the USB expander, my USB mouse lags and jumps in large steps every second or so, while using the motherboard USB does not present this problem. My TV card will only do one or two frames per second, and the program (xawtv) usually times out and crashes. In dmesg, I'm getting messages like: bttv0: timeout: drop=74, irq=154/100476, risc=31f6256c, bits: VSYNC HSYNC OFLOW RISCI for my TV card, and similar timeout issues for my USB expander with a mouse. I received the motherboard, processor and RAM second hand and have only just got around to building it, so I don't know if this problem has always existed, or if it's a result of my set up. If anyone has any hints or solutions it would be appreciated - this is kind of a show-stopper for me.

    Read the article

  • FFmpeg convert video w/ dropped frames, out of sync

    - by preahkumpii
    I recorded a video using Bandicam with the MJPEG encoder to get the least amount of lag. Now, I am trying to convert that massive file to a h264 avi using ffmpeg. I know there are dropped frames in the video stream...more than 100 in the first two minutes, which I assume is simply because Bandicam dropped some when it couldn't keep up. So, when I convert the file to h264, the video and audio are out of sync, and appear to be more and more out of sync as output video progresses. Here is my basic command in ffmpeg: ffmpeg -i "C:\...\input.avi" -vcodec libx264 -q 5 -acodec libmp3lame -ar 44100 -ac 2 -b:a 128k "C:\...\output.avi" I have tried EVERYTHING I can think of including: -itsoffset [-]00:00:01 Tried this before and after input file. This doesn't work because as the video progresses it becomes more and more out of sync. -async 1 Doesn't work. -vsync 1 Doesn't work, but it does show dropped frames being duplicated. Two inputs of same file with mapping using -map 0:0 -map 1:1. Doesn't work. The source plays just fine. Any ideas how to convert it with ffmpeg and keep the audio and video synced? Thanks.

    Read the article

  • raid 0 data recovery?

    - by Fred
    HI All, I have two identical seagate 7200.9 500Gb drives confiured as a RAID 0 spanned disk in windows. One of the drives has lost power and wont spin up at all. I know this normally means death for the data on both drives but i have a cunning plan.. DISK 1 - NO POWER RAID 0 DISK DISK 2 - FULLY FUNCTIONAL RAID 0 DISK DISK 3 - FULLY FUNCTIONAL SPARE DISK Copy the working drive (disk 2) data to a third 500GB DISK (disk 3), remove the logic board from the working disk (disk 2) and replace it with the non working logic board on the broken drive (disk 1) , then hopefully recreate the RAID 0 with disk 1 and disk 3, just long enough to get the data off it. Hope this makes sense, here are my questions: Windows disk manager atm recognises disk 2 but wont let me access it in anyway, therefore copying the data off it (or getting a disk image) cant be done in windows. Does anyone know of any software (in linux or self booting) that would allow me to access this disk? Anyone know of any software that will recreate the spanned drive off two disk images Am i missing any key information that means i definitely shouldn't even bother starting this, i know its a long shot anyway but its worth a try unless i definitely cant do it. The irritating thing is that i am sure its a logic board failure on disk 1 as it simply wont power up at all, suddenly no signs of life, so i am sure the data is intact! Any help would be really appreciated! Thanks

    Read the article

  • VLAN ACLs and when to go Layer 3

    - by wuckachucka
    I want to: a) segment several departments into VLANs with the hopes of restricting access between them completely (Sales never needs to talk to Support's workstations or printers and vice-versa) or b) certain IP addresses and TCP/UDP ports across VLANS -- i.e. permitting the Sales VLAN to access the CRM Web Server in the Server VLAN on port 443 only. Port-wise, I'll need a 48-port switch and another 24-port switch to go with the two existing 24-port Layer 2 switches (Linksys); I'm looking at going with D-Links or HP Procurves as Cisco is out of our price range. Question #1: From what I understand (and please correct me if I'm wrong), if the Servers (VLAN10) and Sales (VLAN20) are all on the same 48-port switch (or two stacked 24-port switches), afaik, the switch "knows" what VLANs and ports each device belongs to and will switch packets between them; I can also apply ACLs to restrict access between VLANs at this point. Is this correct? Question #2: Now lets say that Support (VLAN30) is on a different switch (one of the Linksys) switches. I'm assuming I'll need to trunk (tag) switch #2's VLANs across to switch #1, so switch #1 sees switch #2's VLAN30 (and vice-versa). Once Switch #1 can "see" VLAN30, I'm assuming I can then apply ACLs as stated in Question #1. Is this correct? Question #3: Once Switch #1 can see all the VLANs, can I achieve the seemingly "Layer 3" ACL filtering of restricting access to Server VLAN on only certain TCP/UDP ports and IP addresses (say, only permitting 3389 to the Terminal Server, 192.168.10.4/32). I say "seemingly" because some of the Layer 2 switches mention the ability to restrict ports and IP addresses through the ACLs; I (perhaps mistakenly) thought that in order to have Layer 3 ACLs (packet filtering), I'd need to have at least one Layer 3 switch acting as a core router. If my assumptions are incorrect, at which point do you need a Layer 3 switch for inter-VLAN routing vs. inter-VLAN switching? Is it generally only when you need that higher-level packet filtering ability between your departments?

    Read the article

  • DD-WRT Acces Point as a Router

    - by Dzh
    Following suggestion to this question asked on Network Engineering, I am asking the question here. this is an extension to my previous question (I think it was deleted), where I was claiming that DDWRT was disabling it's DHCP server once connected to the network. I was wrong, as it now seems that it is bridging itself with another parallel connected wireless router. I have two Draytek 2820 and one Netgear WG602v3 with latest DDWRT. Lets call one wired-Draytek and it has wireless disabled. The other one, let's call it wireless-Draytek, is connected to wired-Draytek and has wireless with MAC filtering enabled. Once I connect Netgear to the wired-Draytek, the client that connects to Netgear, will be assigned with IP address from the wireless-Draytek. If the MAC address is not on the wireles-Draytek, the client is unable to obtain IP address and has no connectivity at all, even with manually assigned static IP configuration. To illustrate further, this is how network is set up: wired-Draytek ---------- wireless-Draytek \_________ Netgear What I wish to have, is that Netgear issues IP addresses from it's own IP pool and ignores the MAC filtering rules from wireless-Draytek. This is kind of puzzling how this they are bridging (if they are) themselves automatically. Thanks. UPDATE: It's not a home network. I gave you a bit simplified set-up. If there is a better site on Stack Exchange to ask this, please let me know. The Drayteks are running stock firmware, it's only Netgear that I've flashed to get more stability. In addition to these routers, I have also three 3COM Baseline switch 2824, and another Draytek router with Prosafe FS752TP PoE switch dedicated for VoIP phones. Wired-Draytek has IP 10.0.0.1, DHCP disabled as there is AD DC which is issuing IP addresses. Wireless-Draytek has IP 1.1.1.1 and DHCP enabled. Netgear has default - 192.168.1.1. As per suggestion, the specific question is - how do I isolate these two wireless routers?

    Read the article

  • Ubuntu 12.10, Unity, AMD 12.11 beta drivers, AMD APP SDK 2.7 and OpenCL detection of multiple gpus

    - by junkie
    I'm using Ubuntu 12.10, AMD 12.11 beta drivers, AMD APP SDK 2.7 and OpenCL. I have three amd radeon 7990s plugged in each of which are a dual 7970 so I have six gpus altogether. I plan to go up to eight in a few days. Windows couldn't use even 4 but linux works fine with 6 so far. The strange thing is that the six gpus are only detected by OpenCL in unity (the ubuntu default window manager). If I switch to e17, blackbox or fluxbox or anything else for that matter OpenCL only detects one. I'm using a simple OpenCL program to list all devices to check. I've also checked the output of aticonfig --list-adapters, fglxinfo and clinfo. The first two always show six in all window managers wheras clinfo shows 6 in unity but 1 gpu in all other WMs. I'm also using an X config generated by aticonfig --initial -f --adapter=all. I'm also only using one monitor. I've also checked using lsmod that the fglrx module is loaded in all WMs. So I have two questions. Why does OpenCL see six gpus only in unity? How can I enable six gpus on other lightweight WMs? Basically I'm getting at what determines how many gpus the OpenCL runtime sees? Thanks.

    Read the article

  • Installing Linux on a Windows 8.1 laptop

    - by nicoX
    I would like to clean install a linux distribution as Ubuntu etc. My laptop that runs Windows 8.1. I have two options in mind. Clean install or dual boot. My technical question is: my laptop have a 8GB SSD drive, which it uses to boot Windows with and a 500GB for storage. I wonder what that 8GB SSD stores? It can't store the whole Windows install as that would be much more than 8GB. Also if I would do a clean install of Ubuntu could I use the 8GB SSD to have Ubuntu boot up quicker. How would I install it. Option two, if I would like to dual boot, how would I proceed having the SSD to boot both systems? I also wish to ask about the Legacy and UEFI differences. Windows runs with UEFI. So when I'm installing Linux, should I run Legacy, and if I dual boot, what option to I choose?

    Read the article

  • EMC VNX iSCSI setup - unsure about SP/port assignment

    - by pauska
    We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. It has 4x1gbit iSCSI per SP (8 ports in total), and I'd like to get the most out of the performance until we jump over to 10gig iSCSI. From what I can read from the docs - the recommendation is to use only two ports per SP, with 1 active and 1 passive. Why is this? It seems kind of pointless to have quad-port i/o-modules and then recommend to not use more than two of them? Also - I'm a bit unsure about the zoning. The best practices guide state that you should separate each port on each SP from each other on different logical networks. Does this mean that I have to create 4 logical networks to be able to use all 8 ports? It also gives the following example: Does this mean that A0 and B0 should sit on the same physical switch aswell? Won't this make all traffic go on one switch (if both A1 and B1 are passive)? Edit: Another brainpuzzle I don't get it - each host (as in server) should not have more iSCSI bandwidth available than the storage processor. What on earth does this matter? If serverA have 1gbit and serverB have 100mbit, then the resulting bandwith between them is 100mbit. How can this result in some kind of oversubscription? Edit4: Wait, what. Active and passive ports? The VNX runs in a ALUA configuration with asymmetrical active/active.. there shouldn't be any passive ports, only preferred ones..

    Read the article

  • Is it possible to open a sqlite database from within microsoft sql management studio?

    - by Brian T Hannan
    Is there a way to open a .db file (sqlite database file) from within microsoft sql management studio? Right now we have a process that will grab the data from a microsoft sql server database and put it into a sqlite database file that will be used by an application later on. Is there a way to open the sqlite database file so that it can be compared to the data inside the sql server database ... using only one sql query? Is there a plug-in for microsoft sql management studio? Or maybe there is another way to do this same task using only one query. Right now we have to write two scripts ... one for sql server database and one for sqlite database ... then take the output from each in the same format and put them each in their own OpenOffice spreadsheet file. Finally, we compare the two files to see if there are any differences. Perhaps there's a better way to do this. P.S. Alot of applications use sqlite internally: Well-Known Users Of SQLite

    Read the article

  • Should I use "Raid 5 + spare" or "Raid 6"?

    - by Trevor Boyd Smith
    What is "Raid 5 + Spare" (excerpt from User Manual, Sect 4.17.2, P.54): RAID5+Spare: RAID 5+Spare is a RAID 5 array in which one disk is used as spare to rebuild the system as soon as a disk fails (Fig. 79). At least four disks are required. If one physical disk fails, the data remains available because it is read from the parity blocks. Data from a failed disk is rebuilt onto the hot spare disk. When a failed disk is replaced, the replacement becomes the new hot spare. No data is lost in the case of a single disk failure, but if a second disk fails before the system can rebuild data to the hot spare, all data in the array will be lost. What is "Raid 6" (excerpt from User Manual, Sect 4.17.2, P.54): RAID6: In RAID 6, data is striped across all disks (minimum of four) and a two parity blocks for each data block (p and q in Fig. 80) is written on the same stripe. If one physical disk fails, the data from the failed disk can be rebuilt onto a replacement disk. This Raid mode can support up to two disk failures with no data loss. RAID 6 provides for faster rebuilding of data from a failed disk. Both "Raid 5 + spare" and "Raid 6" are SO similar ... I can't tell the difference. When would "Raid 5 + Spare" be optimal? And when would "Raid 6" be optimal"? The manual dumbs down the different raid with 5 star ratings. "Raid 5 + Spare" only gets 4 stars but "Raid 6" gets 5 stars. If I were to blindly trust the manual I would conclude that "Raid 6" is always better. Is "Raid 6" always better?

    Read the article

  • Dell Latitude D510 Runs From Battery But Not AC Adapter

    - by Jason George
    I have a Dell Latitude D510 that went belly up around two years ago. It will run from the battery, however, the wall adapter will neither power the machine nor charge the battery. Once the battery is dead, the machine is dead. Since it died I've searched repeatedly for solutions. I've tried a new AC adapter and even removed and replaced the DC jack thinking one of the solder joints might be bad. Both to no avail. After two years of searching I finally found the answer today. Since it's such a simple fix and I had such a hard time finding it I wanted to post the info for others (as it is apparently a common issue with the D510). -----SOLUTION----- It seems this is commonly caused by a cracked solder joint at pin 1 on an inductor filter pair (FL2) near the power jack. Pins 1 and 4 are ground and pins 2 and 3 are power. There should be 20V from 1 to 2 and 3. Anything less indicates a cracked joint that is increasing resistance and dropping the supply voltage. Repair simply requires reflowing all four pins with a little added solder for security. Detailed instructions can be found here. Dell Latitude D510 solder problem

    Read the article

  • Constant CMS Session Expiry On 1&1 Cloud Server?

    - by leen3o
    I have a couple of 1&1's 'Dynamic Cloud Servers' and running Win2008R2 and they are setup as web servers, I have a number of Umbraco CMS installs on them and they have been running fine for over a year. On Saturday on BOTH servers, a very strange thing happened - As soon as I login to the CMS/Umbraco admin I am logged out with about 5 seconds? It's as if my session expires the moment I login? I have checked everything I can as I'm not really a server admin, and everything seems to be exactly as it was last week? Like I say this has happened EXACTLY the same time (Saturday) on TWO different servers? I'm just looking for ideas of what I should be looking for? Also the front end of the sites seem fine... Its only the backend when I login. I have gone to 1&1 about this, and as usual they have washed their hands saying its nothing to do with them - When I am certain it is. How can this happen on two different servers, and affect the same sites in exactly the same way? Any help, tips, things to try would be greatly appreciated.

    Read the article

< Previous Page | 475 476 477 478 479 480 481 482 483 484 485 486  | Next Page >