Search Results

Search found 36698 results on 1468 pages for 'old linux fan'.

Page 489/1468 | < Previous Page | 485 486 487 488 489 490 491 492 493 494 495 496  | Next Page >

  • Linux Software RAID1 Rebuild Completes, but after reboot, its degraded again

    - by zimmy6996
    I have been beating my head with an issue here, and I'm now turning to the internet for help. I have a system running Mandrake Linux, with the following configuration: /dev/hda - This is a IDE drive. Has some partitions on it that boot the system and make up most of the file system. /dev/sda - This is drive 1 of 2 for a software raid /dev/md0 /dev/sdb - This is drive 2 of 2 for a software raid /dev/md0 md0 gets mounted but fstab as /data-storage, so it is not critical to the systems ability to boot. We can comment it out of fstab, and the system works just fine either way. The problem is, we have a failed sdb drive. So I shut the box down, and have pulled the failed disk and installed a new disk. When the system boots up, /proc/mdstat shows only sda as part of the raid. I then run the various command to rebuild the RAID to /dev/sdb. Everything rebuilds correctly, and upon completion, you look at /proc/mdstat and it shows 2 drives sda1(0) and sdb1(1). Everything looks great. Then you reboot the box ... UGH!!! Once rebooted, sdb is missing again from the RAID. It is like the rebuild never happened. I can walk through the commands to rebuild it again, and it will work, but again, after reboot, the box seems to make sdb just vanish! The real odd thing is, if after reboot, I pull sda out of the box, and try to get the system to load with the rebuilt sdb drive in the system, and when I do, the system actually throws and error just after grub, and says something about drive error, and the system has to shut down. Thoughts??? I'm starting to wonder if grub has something to do with this mess. That the drive isn't being setup within grub to be visible at boot? This RAID array isn't necessary for the system to boot, but when the replacement drive is in there, without SDA it won't boot system, so it makes me believe there is something to that. On top of that, there just seems to be something wonky here the drive falling off of RAID after reboot. I've hit the point of pounding my head on the keyboard. Any help would be greatly appreciated!!!

    Read the article

  • Linux bonded Interfaces hanging periodically

    - by David
    I've several hosts that are showing problems with connectivity. When working from the command line, for example, typing is frozen for a second or so, then recovers - then it does it again. The most egregious example host would freeze (input) for 15-30 seconds, then recover and go out 5 seconds later. Switching cables didn't do anything - but removing one of the physical cables caused everything to clear up instantly (which why I think this is a network problem). Looking at the network I couldn't see any packets floating that would explain this. These ethernet interfaces (Gigabit Dell) were working normally previously, but since we moved the systems - and put them on a new set of switches - this has been a problem on multiple theoretically identically-configured hosts. The original switches were an HP Procurve 1810-24G and an HP Procurve 1800-24G connected with LLDP; the new switches are both Cisco SG 200-26, which I understand are rebranded Linksys switches. Is this caused by a problem with the switches? Is it the switch configurations? Are the Cisco switches incapable of handling this? I don't see where the configuration is located; I searched the usual /etc/sysconfig/network/devices but there's nothing in there about options (like mii polling) and nothing about the method of balancing the two. Searching scripts, I can't find anything in /etc/init.d/network either. The hosts are almost all Red Hat Enterprise Linux 5.x systems (5.6, 5.7) but some are Ubuntu Server 10.04.3 Lucid Lynx. I need help with both if it comes to that. UPDATE: We're also seeing some problems with servers on the original switches. The HP switches and the Cisco switches are also interconnected (temporarily); there is a cable run from one switch to the next. Pings on any of these hosts show about one ICMP packet out of every 5-6 getting dropped (timed out). Could there be an interaction between the two switches? Oh, and the hosts are using bonding with Balance-RR as the method.

    Read the article

  • Reliable file copy (move) process - mostly Unix/Linux

    - by mfinni
    Short story : We have a need for a rock-solid reliable file mover process. We have source directories that are often being written to that we need to move files from. The files come in pairs - a big binary, and a small XML index. We get a CTL file that defines these file bundles. There is a process that operates on the files once they are in the destination directory; that gets rid of them when it's done. Would rsync do the best job, or do we need to get more complex? Long story as follows : We have multiple sources to pull from : one set of directories are on a Windows machine (that does have Cygwin and an SSH daemon), and a whole pile of directories are on a set of SFTP servers (Most of these are also Windows.) Our destinations are a list of directories on AIX servers. We used to use a very reliable Perl script on the Windows/Cygwin machine when it was our only source. However, we're working on getting rid of that machine, and there are other sources now, the SFTP servers, that we cannot presently run our own scripts on. For security reasons, we can't run the copy jobs on our AIX servers - they have no access to the source servers. We currently have a homegrown Java program on a Linux machine that uses SFTP to pull from the various new SFTP source directories, copies to a local tmp directory, verifies that everything is present, then copies that to the AIX machines, and then deletes the files from the source. However, we're finding any number of bugs or poorly-handled error checking. None of us are Java experts, so fixing/improving this may be difficult. Concerns for us are: With a remote source (SFTP), will rsync leave alone any file still being written? Some of these files are large. From reading the docs, it seems like rysnc will be very good about not removing the source until the destination is reliably written. Does anyone have experience confirming or disproving this? Additional info We will be concerned about the ingestion process that operates on the files once they are in the destination directory. We don't want it operating on files while we are in the process of copying them; it waits until the small XML index file is present. Our current copy job are supposed to copy the XML file last. Sometimes the network has problems, sometimes the SFTP source servers crap out on us. Sometimes we typo the config files and a destination directory doesn't exist. We never want to lose a file due to this sort of error. We need good logs If you were presented with this, would you just script up some rsync? Or would you build or buy a tool, and if so, what would it be (or what technologies would it use?) I (and others on my team) are decent with Perl.

    Read the article

  • Set up linux box for hosting a-z

    - by microchasm
    I am in the process of reinstalling the OS on a machine that will be used to host a couple of apps for our business. The apps will be local only; access from external clients will be via vpn only. The prior setup used a hosting control panel (Plesk) for most of the admin, and I was looking at using another similar piece of software for the reinstall - but I figured I should finally learn how it all works. I can do most of the things the software would do for me, but am unclear on the symbiosis of it all. This is all an attempt to further distance myself from the land of Configuration Programmer/Programmer, if at all possible. I can't find a full walkthrough anywhere for what I'm looking for, so I thought I'd put up this question, and if people can help me on the way I will edit this with the answers, and document my progress/pitfalls. Hopefully someday this will help someone down the line. The details: CentOS 5.5 x86_64 httpd: Apache/2.2.3 mysql: 5.0.77 (to be upgraded) php: 5.1 (to be upgraded) The requirements: SECURITY!! Secure file transfer Secure client access (SSL Certs and CA) Secure data storage Virtualhosts/multiple subdomains Local email would be nice, but not critical The Steps: Download latest CentOS DVD-iso (torrent worked great for me). Install CentOS: While going through the install, I checked the Server Components option thinking I was going to be using another Plesk-like admin. In hindsight, considering I've decided to try to go my own way, this probably wasn't the best idea. Basic config: Setup users, networking/ip address etc. Yum update/upgrade. Upgrade PHP/MySQL: To upgrade PHP and MySQL to the latest versions, I had to look to another repo outside CentOS. IUS looks great and I'm happy I found it! Add IUS repository to our package manager cd /tmp wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/epel-release-1-1.ius.el5.noarch.rpm rpm -Uvh epel-release-1-1.ius.el5.noarch.rpm wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/ius-release-1-4.ius.el5.noarch.rpm rpm -Uvh ius-release-1-4.ius.el5.noarch.rpm yum list | grep -w \.ius\. # list all the packages in the IUS repository; use this to find PHP/MySQL version and libraries you want to install Remove old version of PHP and install newer version from IUS rpm -qa | grep php # to list all of the installed php packages we want to remove yum shell # open an interactive yum shell remove php-common php-mysql php-cli #remove installed PHP components install php53 php53-mysql php53-cli php53-common #add packages you want transaction solve #important!! checks for dependencies transaction run #important!! does the actual installation of packages. [control+d] #exit yum shell php -v PHP 5.3.2 (cli) (built: Apr 6 2010 18:13:45) Upgrade MySQL from IUS repository /etc/init.d/mysqld stop rpm -qa | grep mysql # to see installed mysql packages yum shell remove mysql mysql-server #remove installed MySQL components install mysql51 mysql51-server mysql51-devel transaction solve #important!! checks for dependencies transaction run #important!! does the actual installation of packages. [control+d] #exit yum shell service mysqld start mysql -v Server version: 5.1.42-ius Distributed by The IUS Community Project Upgrade instructions courtesy of IUS wiki: http://wiki.iuscommunity.org/Doc/ClientUsageGuide Install rssh (restricted shell) to provide scp and sftp access, without allowing ssh login cd /tmp wget http://dag.wieers.com/rpm/packages/rssh/rssh-2.3.2-1.2.el5.rf.x86_64.rpm rpm -ivh rssh-2.3.2-1.2.el5.rf.x86_64.rpm useradd -m -d /home/dev -s /usr/bin/rssh dev passwd dev Edit /etc/rssh.conf to grant access to SFTP to rssh users. vi /etc/rssh.conf Uncomment or add: allowscp allowsftp This allows me to connect to the machine via SFTP protocol in Transmit (my FTP program of choice; I'm sure it's similar with other FTP apps). rssh instructions appropriated (with appreciation!) from http://www.cyberciti.biz/tips/linux-unix-restrict-shell-access-with-rssh.html Set up virtual interfaces ifconfig eth1:1 192.168.1.3 up #start up the virtual interface cd /etc/sysconfig/network-scripts/ cp ifcfg-eth1 ifcfg-eth1:1 #copy default script and match name to our virtual interface vi ifcfg-eth1:1 #modify eth1:1 script #ifcfg-eth1:1 | modify so it looks like this: DEVICE=eth1:1 IPADDR=192.168.1.3 NETMASK=255.255.255.0 NETWORK=192.168.1.0 ONBOOT=yes NAME=eth1:1 Add more Virtual interfaces as needed by repeating. Because of the ONBOOT=yes line in the ifcfg-eth1:1 file, this interface will be brought up when the system boots, or the network starts/restarts. service network restart Shutting down interface eth0: [ OK ] Shutting down interface eth1: [ OK ] Shutting down loopback interface: [ OK ] Bringing up loopback interface: [ OK ] Bringing up interface eth0: [ OK ] Bringing up interface eth1: [ OK ] ping 192.168.1.3 64 bytes from 192.168.1.3: icmp_seq=1 ttl=64 time=0.105 ms And this is where I'm at. I will keep editing this as I make progress. Any tips on how to Configure virtual interfaces/ip based virtual hosts for SSL, setting up a CA, or anything else would be appreciated.

    Read the article

  • C program runs in Cygwin but not Linux (Malloc)

    - by Shawn
    I have a heap allocation error that I cant spot in my code that is picked up on vanguard/gdb on Linux but runs perfectly on a Windows cygwin environment. I understand that Linux could be tighter with its heap allocation than Windows but I would really like to have a response that discovers the issue/possible fix. I'm also aware that I shouldn't typecast malloc in C but it's a force of habit and doesn't change my problem from happening. My program actually compiles without error on both Linux & Windows but when I run it in Linux I get a scary looking result: malloc.c:3074: sYSMALLOc: Assertion `(old_top == (((mbinptr) (((char *) &((av)-bins[((1) - 1) * 2])) - __builtin_offsetof (struct malloc_chunk, fd)))) && old_size == 0) || ((unsigned long) (old_size) = (unsigned long)((((__builtin_offsetof (struct malloc_chunk, fd_nextsize))+((2 * (sizeof(size_t))) - 1)) & ~((2 * (sizeof(size_t))) - 1))) && ((old_top)-size & 0x1) && ((unsigned long)old_end & pagemask) == 0)' failed. Aborted Attached snippet from my code that is being pointed to as the error for review: /* Main */ int main(int argc, char * argv[]) { FILE *pFile; unsigned char *buffer; long int lSize; pFile = fopen ( argv[1] , "r" ); if (pFile==NULL) {fputs ("File error on arg[1]",stderr); return 1;} fseek (pFile , 0 , SEEK_END); lSize = ftell (pFile); rewind (pFile); buffer = (char*) malloc(sizeof(char) * lSize+1); if (buffer == NULL) {fputs ("Memory error",stderr); return 2;} bitpair * ppairs = (bitpair *) malloc(sizeof(bitpair) * (lSize+1)); //line 51 below calcpair(ppairs, (lSize+1)); /* irrelevant stuff */ fclose(pFile); free(buffer); free(ppairs); } typedef struct { long unsigned int a; //not actual variable names... Yes I need them to be long unsigned long unsigned int b; long unsigned int c; long unsigned int d; long unsigned int e; } bitpair; void calcpair(bitpair * ppairs, long int bits); void calcPairs(bitpair * ppairs, long int bits) { long int i, top, bot, var_1, var_2; int count = 0; for(i = 0; i < cs; i++) { top = 0; ppairs[top].e = 1; do { bot = count; count++; } while(ppairs[bot].e != 0); ppairs[bot].e = 1; var_1 = bot; var_2 = top; calcpair * bp = &ppairs[var_2]; bp->a = var_2; bp->b = var_1; bp->c = i; bp = &ppairs[var_1]; bp->a = var_2; bp->b = var_1; bp->c = i; } return; } gdb reports: free(): invalid pointer: 0x0000000000603290 * valgrind reports the following message 5 times before exiting due to "VALGRIND INTERNAL ERROR" signal 11 (SIGSEGV): Invalid read of size 8 ==2727== at 0x401043: calcPairs (in /home/user/Documents/5-3/ubuntu test/main) ==2727== by 0x400C9A: main (main.c:51) ==2727== Address 0x5a607a0 is not stack'd, malloc'd or (recently) free'd

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Linux/Apache performance very slow even on local network

    - by klausch
    I have an Ubuntu server machine running Apache and MYSQL. System and version info is as follows: Linux kernel 3.0.0.-12 Apache/2.2.20 MySQL Ver 14.14.Distrib 5.1.58 I am running a few websites on this server, some HTML only, some PHP/MySQL. THe [problem is that response time is very slow, both on static as well as the dynamic sites. Sometimes it takes more than 10 seconds before a response is given, this makes the sites very slow and almost unusable. The problem occurs even when requesting from the local network. I have added the involved subdomains to my /etc/hosts file, and abolve all the problem is not solved by using IP numbers instead of URL's. So there is no DNS lookup issue. I have modified the log format by showing the response times and sometimes a files takes 12 seconds to be served, see the jquery~.js file in the example screenshot. I have no explanation for this extremely long response time, but is is not even the only issue here, some other files takes a long time to be served too, but do not show a long response time in the log file. So probably different tissues are involved here. I cannot find a solution until now, any suggestions??? THanx in advance, Klaas link to screenshot picture from access logfile Some extra configuration info: apache2.conf (comment is removed) LockFile ${APACHE_LOCK_DIR}/accept.lock PidFile ${APACHE_PID_FILE} Timeout 300 KeepAlive On MaxKeepAliveRequests 100 KeepAliveTimeout 5 <IfModule mpm_prefork_module> StartServers 5 MinSpareServers 5 MaxSpareServers 10 MaxClients 150 MaxRequestsPerChild 0 </IfModule> <IfModule mpm_worker_module> StartServers 2 MinSpareThreads 25 MaxSpareThreads 75 ThreadLimit 64 ThreadsPerChild 25 MaxClients 150 MaxRequestsPerChild 0 </IfModule> <IfModule mpm_event_module> StartServers 2 MinSpareThreads 25 MaxSpareThreads 75 ThreadLimit 64 ThreadsPerChild 25 MaxClients 150 MaxRequestsPerChild 0 </IfModule> User ${APACHE_RUN_USER} Group ${APACHE_RUN_GROUP} AccessFileName .htaccess <Files ~ "^\.ht"> Order allow,deny Deny from all Satisfy all </Files> DefaultType text/plain HostnameLookups Off ErrorLog ${APACHE_LOG_DIR}/error.log LogLevel warn Include mods-enabled/*.load Include mods-enabled/*.conf Include httpd.conf Include ports.conf LogFormat "%v:%p %h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\"" vhost_combined LogFormat "%h %l %u %t \"%r\" %>s %O \"%{Referer}i\" \"%{User-Agent}i\" %T/%D" combined LogFormat "%h %l %u %t \"%r\" %>s %O" common LogFormat "%{Referer}i -> %U" referer LogFormat "%{User-agent}i" agent Include conf.d/ Include sites-enabled/ And the virtual hostfile for one of the slow sites, in fact it is pretty straightforward... <VirtualHost *:80> ServerAdmin [email protected] ServerSignature EMail ServerName toenjoy.drsklaus.nl DocumentRoot /var/www/toenjoy.drsklaus.nl <Directory /> Options FollowSymLinks AllowOverride None </Directory> <Directory /var/www/toenjoy.drsklaus.nl/> Options Indexes FollowSymLinks MultiViews AllowOverride AuthConfig AuthType Basic AuthName "To Enjoy" AuthUserFile /etc/.htpasswd Require user petraaa Order allow,deny allow from all </Directory> ScriptAlias /cgi-bin/ /usr/lib/cgi-bin/ <Directory "/usr/lib/cgi-bin"> AllowOverride None Options +ExecCGI -MultiViews +SymLinksIfOwnerMatch Order allow,deny Allow from all </Directory> ErrorLog /var/log/apache2/error.log # Possible values include: debug, info, notice, warn, error, crit, # alert, emerg. LogLevel warn CustomLog /var/log/apache2/access.log combined Alias /doc/ "/usr/share/doc/" <Directory "/usr/share/doc/"> Options Indexes MultiViews FollowSymLinks AllowOverride None Order deny,allow Deny from all Allow from 127.0.0.0/255.0.0.0 ::1/128 </Directory> </VirtualHost> And the output of free -m: klaas@ubuntu-server:/etc/apache2$ free -m total used free shared buffers cached Mem: 1997 1401 595 0 144 1017 -/+ buffers/cache: 238 1758 Swap: 2035 0 2035 and I have no indication that swapping occurs on the moments the site is slow. I have runned top and it does not appear to be a CPU issue. I have the impression that the spawning of a apache thread could maybe be the bottleneck but it is just a suggestion. Maybe this gives some extra information! EDIT: The problem seemed to be gone for some time but occurs again! And not only with Apache, also connecting using SSH takes a tremendous time, sometimes it takes up to 15 seconds before the keyphrase is asked for. Also scp works very slowly. The behavious is really unpredoctable and makes the server very hard to use. Any ideas...?

    Read the article

  • Trouble with codeblocks installation on Ubuntu 9.10

    - by chester89
    I installed Code::Blocks on Ubuntu 9.10, but when I start it from terminal, it shows the following error: relocation error: /usr/lib/libcodeblocks.so.0: symbol _Z18wxSafeConvertWX2MBPKw, version WXU_2.8.2 not defined in file libwx_baseu-2.8.so.0 with link time reference What is wrong with it? It seems to me I have installed all necessary libraries. Any ideas? P.S. I am a Linux noobie - so sorry if it is some kind of a well-known mistake.

    Read the article

  • Find folders with specific name and no symlink pointing to them

    - by Stefan
    Hey guys, I'm trying to write a shell script under linux, which lists all folders (recursively) with a certain name and no symlink pointing to it. For example I have /home/htdocs/cust1/typo3_src-4.2.11 /home/htdocs/cust2/typo3_src-4.2.12 /home/htdocs/cust3/typo3_src-4.2.12 Now I want to go through all subdirectories of /home/htdocs and find those folders typo3_*, that are not pointed to from somewhere. Should be possible with a shellscript or a command, but I have no idea how. Thanks for you help Stefan

    Read the article

  • Application Interface between a PC and an embedded device

    - by sasayins
    Hi, How can I make an application interface so that a PC application can communicate to an embedded device like a POS terminal? Like for example, an embedded device like POS terminal that has an embedded linux as an OS. Then I want a PC application to communicate in that POS terminal and access its module hardware like for example its magnetic stripe reader. What implementation should I create in the device, should I use CORBA or something related in that technology so that a PC application can communicate in the POS terminal? Many thanks.

    Read the article

  • How to get status from POS Printer

    - by Cris
    Hello, i'm trying to find a way to get paper status from a POS printer; i think i would use GS a, GS r sequence but i cannot understand how to return info from the printer; i'm under Linux, where does the POS printer returns info about status? Thanks in advance, Cris

    Read the article

  • UUID library for C?

    - by ptomato
    I'm looking for a UUID library for programming in C, that has a reasonable probability of being installed (or at least installable by package manager) on most modern Linux desktops, and works with pkg-config. The following two possibilities seem most obvious: OSSP UUID Libuuid from e2fsprogs Does anybody have experience with these two and can recommend one over the other, or a third possiblity?

    Read the article

  • how to print map value in gdb

    - by Davit Siradeghyan
    Hi all I have a std::map< std::string, std::string cont; I want to see cont[ "some_key" ] in gdb. When I'm trying p cont[ "some_ket" ] I'm getting this message: One of the arguments you tried to pass to operator[] could not be converted to what the function wants. I'm using GNU gdb Red Hat Linux (6.3.0.0-1.162.el4rh). Thanks

    Read the article

  • determine if chipset is capable off packet injection and monitor mode

    - by Richard
    Hi, I am new to linux and I want to know if my chipset is capable off doing those things My chipset is a intel centrino advanced 6200-n on a sony vayo laptop running on windows 7. Now, I know that windows is only capable off listening, so I boot backtrack 4 from a usb stick. I also want to know if a live distribution can work flawlessly with the wificard even if it does not support formentioned things, because I try'd to use wget to download something and it says it ca not resolve the address? thanks, Richard

    Read the article

  • Using Valgrind tool how can I detect which object trying to access 0x0 address ?

    - by Davit Siradeghyan
    I have this output when trying to debug Program received signal SIGSEGV, Segmentation fault 0x43989029 in std::string::compare (this=0x88fd430, __str=@0xbfff9060) at /home/devsw/tmp/objdir/i686-pc-linux-gnu/libstdc++-v3/include/bits/char_traits.h:253 253 { return memcmp(__s1, __s2, __n); } Current language: auto; currently c++ Using valgrind I getting this output ==12485== Process terminating with default action of signal 11 (SIGSEGV) ==12485== Bad permissions for mapped region at address 0x0 ==12485== at 0x1: (within path_to_my_executable_file/executable_file)

    Read the article

  • optimizing operating systems to provide maximum informix performance.

    - by Frank Developer
    Are there any Informix-specific guides for optimizing any operating system where an ifx engine is running? For example, in Linux, strip-down to a bare minimum all unecessary binaries, daemons, utilities, tune kernel parameters, optimize raw and cooked devices (hdparm). Someday, maybe, informix can create its own proprietary PICK-like O/S. The general idea is for the OS where ifx sits on have the smallest footprint, lowest overhead impact on ifx and provide optimized ifx performance.

    Read the article

  • How to use a defined struct from another source file?

    - by sasayins
    Hi, I am using Linux as my programming platform and C language as my programming language. My problem is, I define a structure in my main source file( main.c): struct test_st { int state; int status; }; So I want this structure to use in my other source file(e.g. othersrc.). Is it possible to use this structure in another source file without putting this structure in a header? Thanks

    Read the article

  • OpenCV videos across platform

    - by Gurman Gill
    I am writing a video using OpenCV on linux machine. I want to read the same video using OpenCV on a windows machine. I am not able to do this using the standard codecs provided in openCV. Can anybody suggest how I can read/write videos across the two platforms?

    Read the article

  • "tracing" version of readlink(1)

    - by jonrock
    I would like a version of "readlink -f" that provides a trace of every individual symlink resolution it performs. Something like: $ linktrace /usr/lib64/sendmail /usr/lib64 -> lib /usr/lib/sendmail -> ../sbin/sendmail /usr/sbin/sendmail $ I know I have used this utility in the past, on linux, and also remember at the time thinking "the name of this tool is completely unintuitive and I will forget it". Well, that day has arrived.

    Read the article

  • libpcap packet size

    - by silverbandit91
    I'm working with libpcap in C on linux (centos) and I'm following this guide I want to simply print out the entire packet in ascii and i'v managed to get it working by casting it a u_char* in the "my_callback" function. But I can't figure out how to get the length of the data. strstr didn't work. the header has a len member that you can access to get the size but I can't find anything similar for the *packet being passed. Any help is appreciated.

    Read the article

  • Framebuffer Documentation...

    - by NoMoreZealots
    Is there any documentation on how to write software that uses the framebuffer device in Linux? I've seen a couple simple examples that basically say: "open it, mmap it, write pixels to mapped area." But no comprehensive documentation on how to use the different IOCTLS for it anything. I've seen references to "panning" and other capabilities but "googling it" gives way too many hits of useless information.

    Read the article

< Previous Page | 485 486 487 488 489 490 491 492 493 494 495 496  | Next Page >