Search Results

Search found 21184 results on 848 pages for 'cable internet'.

Page 532/848 | < Previous Page | 528 529 530 531 532 533 534 535 536 537 538 539  | Next Page >

  • HDMI Sound Stops Working

    - by stueng
    When not used for a few hours the sound stops working on my HTPC. To get sound to work again I have to unplug the HDMI cable and plug it back in again When this sound "outage" occurs, the HDMI device dissapears from the sound config output devices I see the following in dmesg [78534.010328] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78534.010363] HDMI status: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78558.948403] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78558.948429] HDMI status: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78562.579047] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=0 [78562.579078] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78562.579992] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=1 [78562.580043] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78562.876030] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78563.176036] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78563.195139] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78563.195169] HDMI status: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78563.476030] HDMI status: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78635.529493] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78635.529524] HDMI status: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=0 [78641.330701] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=0 [78641.330733] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78641.331649] HDMI hot plug event: Codec=0 Pin=3 Presence_Detect=0 ELD_Valid=1 [78641.331668] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78641.628050] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78641.928037] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78642.228042] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78642.528039] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1 [78642.828037] HDMI status: Codec=0 Pin=3 Presence_Detect=1 ELD_Valid=1

    Read the article

  • How to Avoid Your Next 12-Month Science Project

    - by constant
    While most customers immediately understand how the magic of Oracle's Hybrid Columnar Compression, intelligent storage servers and flash memory make Exadata uniquely powerful against home-grown database systems, some people think that Exalogic is nothing more than a bunch of x86 servers, a storage appliance and an InfiniBand (IB) network, built into a single rack. After all, isn't this exactly what the High Performance Computing (HPC) world has been doing for decades? On the surface, this may be true. And some people tried exactly that: They tried to put together their own version of Exalogic, but then they discover there's a lot more to building a system than buying hardware and assembling it together. IT is not Ikea. Why is that so? Could it be there's more going on behind the scenes than merely putting together a bunch of servers, a storage array and an InfiniBand network into a rack? Let's explore some of the special sauce that makes Exalogic unique and un-copyable, so you can save yourself from your next 6- to 12-month science project that distracts you from doing real work that adds value to your company. Engineering Systems is Hard Work! The backbone of Exalogic is its InfiniBand network: 4 times better bandwidth than even 10 Gigabit Ethernet, and only about a tenth of its latency. What a potential for increased scalability and throughput across the middleware and database layers! But InfiniBand is a beast that needs to be tamed: It is true that Exalogic uses a standard, open-source Open Fabrics Enterprise Distribution (OFED) InfiniBand driver stack. Unfortunately, this software has been developed by the HPC community with fastest speed in mind (which is good) but, despite the name, not many other enterprise-class requirements are included (which is less good). Here are some of the improvements that Oracle's InfiniBand development team had to add to the OFED stack to make it enterprise-ready, simply because typical HPC users didn't have the need to implement them: More than 100 bug fixes in the pieces that were not related to the Message Passing Interface Protocol (MPI), which is the protocol that HPC users use most of the time, but which is less useful in the enterprise. Performance optimizations and tuning across the whole IB stack: From Switches, Host Channel Adapters (HCAs) and drivers to low-level protocols, middleware and applications. Yes, even the standard HPC IB stack could be improved in terms of performance. Ethernet over IB (EoIB): Exalogic uses InfiniBand internally to reach high performance, but it needs to play nicely with datacenters around it. That's why Oracle added Ethernet over InfiniBand technology to it that allows for creating many virtual 10GBE adapters inside Exalogic's nodes that are aggregated and connected to Exalogic's IB gateway switches. While this is an open standard, it's up to the vendor to implement it. In this case, Oracle integrated the EoIB stack with Oracle's own IB to 10GBE gateway switches, and made it fully virtualized from the beginning. This means that Exalogic customers can completely rewire their server infrastructure inside the rack without having to physically pull or plug a single cable - a must-have for every cloud deployment. Anybody who wants to match this level of integration would need to add an InfiniBand switch development team to their project. Or just buy Oracle's gateway switches, which are conveniently shipped with a whole server infrastructure attached! IPv6 support for InfiniBand's Sockets Direct Protocol (SDP), Reliable Datagram Sockets (RDS), TCP/IP over IB (IPoIB) and EoIB protocols. Because no IPv6 = not very enterprise-class. HA capability for SDP. High Availability is not a big requirement for HPC, but for enterprise-class application servers it is. Every node in Exalogic's InfiniBand network is connected twice for redundancy. If any cable or port or HCA fails, there's always a replacement link ready to take over. This requires extra magic at the protocol level to work. So in addition to Weblogic's failover capabilities, Oracle implemented IB automatic path migration at the SDP level to avoid unnecessary failover operations at the middleware level. Security, for example spoof-protection. Another feature that is less important for traditional users of InfiniBand, but very important for enterprise customers. InfiniBand Partitioning and Quality-of-Service (QoS): One of the first questions we get from customers about Exalogic is: “How can we implement multi-tenancy?” The answer is to partition your IB network, which effectively creates many networks that work independently and that are protected at the lowest networking layer possible. In addition to that, QoS allows administrators to prioritize traffic flow in multi-tenancy environments so they can keep their service levels where it matters most. Resilient IB Fabric Management: InfiniBand is a self-managing network, so a lot of the magic lies in coming up with the right topology and in teaching the subnet manager how to properly discover and manage the network. Oracle's Infiniband switches come with pre-integrated, highly available fabric management with seamless integration into Oracle Enterprise Manager Ops Center. In short: Oracle elevated the OFED InfiniBand stack into an enterprise-class networking infrastructure. Many years and multiple teams of manpower went into the above improvements - this is something you can only get from Oracle, because no other InfiniBand vendor can give you these features across the whole stack! Exabus: Because it's not About the Size of Your Network, it's How You Use it! So let's assume that you somehow were able to get your hands on an enterprise-class IB driver stack. Or maybe you don't care and are just happy with the standard OFED one? Anyway, the next step is to actually leverage that InfiniBand performance. Here are the choices: Use traditional TCP/IP on top of the InfiniBand stack, Develop your own integration between your middleware and the lower-level (but faster) InfiniBand protocols. While more bandwidth is always a good thing, it's actually the low latency that enables superior performance for your applications when running on any networking infrastructure: The lower the latency, the faster the response travels through the network and the more transactions you can close per second. The reason why InfiniBand is such a low latency technology is that it gets rid of most if not all of your traditional networking protocol stack: Data is literally beamed from one region of RAM in one server into another region of RAM in another server with no kernel/drivers/UDP/TCP or other networking stack overhead involved! Which makes option 1 a no-go: Adding TCP/IP on top of InfiniBand is like adding training wheels to your racing bike. It may be ok in the beginning and for development, but it's not quite the performance IB was meant to deliver. Which only leaves option 2: Integrating your middleware with fast, low-level InfiniBand protocols. And this is what Exalogic's "Exabus" technology is all about. Here are a few Exabus features that help applications leverage the performance of InfiniBand in Exalogic: RDMA and SDP integration at the JDBC driver level (SDP), for Oracle Weblogic (SDP), Oracle Coherence (RDMA), Oracle Tuxedo (RDMA) and the new Oracle Traffic Director (RDMA) on Exalogic. Using these protocols, middleware can communicate a lot faster with each other and the Oracle database than by using standard networking protocols, Seamless Integration of Ethernet over InfiniBand from Exalogic's Gateway switches into the OS, Oracle Weblogic optimizations for handling massive amounts of parallel transactions. Because if you have an 8-lane Autobahn, you also need to improve your ramps so you can feed it with many cars in parallel. Integration of Weblogic with Oracle Exadata for faster performance, optimized session management and failover. As you see, “Exabus” is Oracle's word for describing all the InfiniBand enhancements Oracle put into Exalogic: OFED stack enhancements, protocols for faster IB access, and InfiniBand support and optimizations at the virtualization and middleware level. All working together to deliver the full potential of InfiniBand performance. Who else has 100% control over their middleware so they can develop their own low-level protocol integration with InfiniBand? Even if you take an open source approach, you're looking at years of development work to create, test and support a whole new networking technology in your middleware! The Extras: Less Hassle, More Productivity, Faster Time to Market And then there are the other advantages of Engineered Systems that are true for Exalogic the same as they are for every other Engineered System: One simple purchasing process: No headaches due to endless RFPs and no “Will X work with Y?” uncertainties. Everything has been engineered together: All kinds of bugs and problems have been already fixed at the design level that would have only manifested themselves after you have built the system from scratch. Everything is built, tested and integrated at the factory level . Less integration pain for you, faster time to market. Every Exalogic machine world-wide is identical to Oracle's own machines in the lab: Instant replication of any problems you may encounter, faster time to resolution. Simplified patching, management and operations. One throat to choke: Imagine finger-pointing hell for systems that have been put together using several different vendors. Oracle's Engineered Systems have a single phone number that customers can call to get their problems solved. For more business-centric values, read The Business Value of Engineered Systems. Conclusion: Buy Exalogic, or get ready for a 6-12 Month Science Project And here's the reason why it's not easy to "build your own Exalogic": There's a lot of work required to make such a system fly. In fact, anybody who is starting to "just put together a bunch of servers and an InfiniBand network" is really looking at a 6-12 month science project. And the outcome is likely to not be very enterprise-class. And it won't have Exalogic's performance either. Because building an Engineered System is literally rocket science: It takes a lot of time, effort, resources and many iterations of design/test/analyze/fix to build such a system. That's why InfiniBand has been reserved for HPC scientists for such a long time. And only Oracle can bring the power of InfiniBand in an enterprise-class, ready-to use, pre-integrated version to customers, without the develop/integrate/support pain. For more details, check the new Exalogic overview white paper which was updated only recently. P.S.: Thanks to my colleagues Ola, Paul, Don and Andy for helping me put together this article! var flattr_uid = '26528'; var flattr_tle = 'How to Avoid Your Next 12-Month Science Project'; var flattr_dsc = 'While most customers immediately understand how the magic of Oracle's Hybrid Columnar Compression, intelligent storage servers and flash memory make Exadata uniquely powerful against home-grown database systems, some people think that Exalogic is nothing more than a bunch of x86 servers, a storage appliance and an InfiniBand (IB) network, built into a single rack.After all, isn't this exactly what the High Performance Computing (HPC) world has been doing for decades?On the surface, this may be true. And some people tried exactly that: They tried to put together their own version of Exalogic, but then they discover there's a lot more to building a system than buying hardware and assembling it together. IT is not Ikea.Why is that so? Could it be there's more going on behind the scenes than merely putting together a bunch of servers, a storage array and an InfiniBand network into a rack? Let's explore some of the special sauce that makes Exalogic unique and un-copyable, so you can save yourself from your next 6- to 12-month science project that distracts you from doing real work that adds value to your company.'; var flattr_tag = 'Engineered Systems,Engineered Systems,Infiniband,Integration,latency,Oracle,performance'; var flattr_cat = 'text'; var flattr_url = 'http://constantin.glez.de/blog/2012/04/how-avoid-your-next-12-month-science-project'; var flattr_lng = 'en_GB'

    Read the article

  • intermittent DNS problems

    - by jemminger
    How would I go about tracking this issue down? One of my websites has been up for years without issue. We're using Godaddy's nameservers for our domain. Lately in the past two weeks, I've noticed that once from home on my Cox cable connection, I could not connect to the site... it said the domain could not be resolved. I checked downforeveryoneorjustme.com, and it said it was fine. The "outage" lasted maybe five minutes (through a reboot too, and I'm on a mac FWIW) and then it started working again. Then it happened again this week, but from our office on a different Cox connection. Then it happened again from the office, but for a different domain. I called Cox during one outage, and the tech there could resolve the domain without a problem. When these outages are occurring, I can issue "host mydomain.com" and get "domain not found", but using "host mydomain.com 8.8.8.8" will resolve normally. Where do I start? We're getting reports now that our customers are experiencing it too.

    Read the article

  • Hardening network with sysctl settings made Wi-fi downloading speed extremely slow

    - by Rohit Bansal
    I just followed up following steps to harden network security The /etc/sysctl.conf file contain all the sysctl settings. Prevent source routing of incoming packets and log malformed IP's enter the following in a terminal window: sudo vi /etc/sysctl.conf Edit the `/etc/sysctl.conf` file and un-comment or add the following lines : # IP Spoofing protection net.ipv4.conf.all.rp_filter = 1 net.ipv4.conf.default.rp_filter = 1 # Ignore ICMP broadcast requests net.ipv4.icmp_echo_ignore_broadcasts = 1 # Disable source packet routing net.ipv4.conf.all.accept_source_route = 0 net.ipv6.conf.all.accept_source_route = 0 net.ipv4.conf.default.accept_source_route = 0 net.ipv6.conf.default.accept_source_route = 0 # Ignore send redirects net.ipv4.conf.all.send_redirects = 0 net.ipv4.conf.default.send_redirects = 0 # Block SYN attacks net.ipv4.tcp_syncookies = 1 net.ipv4.tcp_max_syn_backlog = 2048 net.ipv4.tcp_synack_retries = 2 net.ipv4.tcp_syn_retries = 5 # Log Martians net.ipv4.conf.all.log_martians = 1 net.ipv4.icmp_ignore_bogus_error_responses = 1 # Ignore ICMP redirects net.ipv4.conf.all.accept_redirects = 0 net.ipv6.conf.all.accept_redirects = 0 net.ipv4.conf.default.accept_redirects = 0 net.ipv6.conf.default.accept_redirects = 0 # Ignore Directed pings net.ipv4.icmp_echo_ignore_all = 1 To reload sysctl with the latest changes, enter: sudo sysctl -p But, after applying the changes I found "Wi-fi" downloading speed and terminal downloading speed extremely slow (less than 1KB/s) however surfing speed through browser was good. But, using direct ethernet cable was giving a good speed. Then, I reverted back the above changes and things fall back in line once again.... Could you please let me know what possibly in above script is affecting such behaviour [and why] ? How could I still maintain hardening of network security without disturbing Wi-fi downloading speed ?

    Read the article

  • How to speed up file transfer to/from Ubuntu Server 11.10 (wifi)

    - by Alexander
    I've been searching AU & elsewhere for the last day and a half. Haven't found an answer so I joined AU to ask for help. I'm hoping someone can point me in the right direction. Ubuntu Server 11.10 Samba VSFTPD Windows 7 PC 2 MacBook Pro - Snow Leopard/Lion 1 iMac - Lion Wireless LAN using DLink DIR-655 Link Speed: 195 Mbit/s on Mac - 54Mbps on Windows ISP Connection: Cable - 20 down/3 up No Domain Controller. All machines are members of the same workgroup. No matter how I connect I can't get better than about 700K transfer rate up/down. Mac/PC, SMB/ftp, Domain Name/Local IP I've tried different user accounts and using different folders, different volumes on the server. Nothing seems to make a difference. 700K up/down. Period. Any suggestions would be greatly appreciated. Thanks, Alexander EDIT: Using sftp now and uploading seems to peak at 980k. After about 5 minutes into a 650MB file, downloading is at 1072k and climbing about 500b/s every ten seconds. If any of that matters... I was expecting a lot faster than 1Mb tx rate. Am I off base here? EDIT: From all I've read so far, perhaps the speed isn't that bad. I only installed Ubuntu out of boredom this past weekend. The trouble is, I like it. Guess it's time to ditch the wifi and run some Cat 5.

    Read the article

  • hdmi AC-3 audio broke after upgrading from 11.10 to 12.04.3

    - by Jim LastName
    I just updated my MythBuntu 11.10 to 12.04.3. Now, when I try to play 5.1 content (ripped DVD), my TV (and receiver) plays a "chattering" sound. I check my receiver and the digital dolby light isn't on--it's in PCM mode. So, either the audio is getting sent as AC-3, but the TV and receiver think it's PCM or the AC-3 audio got converted to multichannel PCM and they can't handle it. My setup: hdmi cable from htpc to TV. TV has an s/pdif output to my receiver. I know TV sends AC-3 audio out correctly because I see digital dolby light come on when I view a digital TV channel and PCM come on when I view an old analog channel. I can connect s/pdif from my htpc to my receiver and the digital dolby light comes on and it can decode the audio just fine. It's just not sending it right over hdmi. Now for some hints to the issue: I noticed in MythTV audio setup when I select alsa:hdmi.... the description only lists 2 channel PCM audio capability. speaker-test -Dhdmi:PCH -c6 errors about a bad channel count (only -c2 works). Finally, I tried vlc and it does the same chattering sound. These all make me think this isn't a MythTV issue, it's something lower than that. I think the best way to troubleshoot this is to start at the drivers and check each layer, one at a time all the way to alsa. I just don't know what the layers are and how to do it. So, I need to find some audio troubleshooting guide to assist me. Or, if one doesn't exist, I'd appreciate some steps. Thanks much, Jim

    Read the article

  • Preventing battery from charging

    - by intuited
    I'm running on UPS power and would like to prevent the laptop's battery from charging, to increase the amount of power available to other devices. Is there a way to do this? update The machine is a Dell Latitude D400. If people want more details, just ask. Also, I'm gathering that I need to explain my desired setup a little better. I've gotten a bunch of suggestions about taking the battery out. I'm not sure if people are suggesting to take the battery out while the machine is running — this, as I understand, is not a good idea with most laptops — or to just remove the battery altogether. The latter option is not optimal, because ideally I'd like to use the 30-60 minutes of power in the laptop battery and then switch over to UPS power. The details of the switch-over may constitute a separate question, but if I can't find a way to keep the laptop battery from charging, then removing the battery from the machine altogether may be the best way to do this. I'm not sure yet if this machine will run without a battery, but I'll check that out. Other than the laptop, the UPS is just supporting a cable modem and router and a USB hub. Again in the idealized version of this setup, all the power management changes would be automated, i.e. not require replugging anything or pressing Fn-keys. I'd like the machine to start using laptop battery power when apcupsd indicates that the UPS A/C is out, and then start using UPS power, but not charging the battery, when the battery is almost depleted.

    Read the article

  • VGA monitor won't detect on NVIDIA Quadro NVS 4200M

    - by tanmayk
    I am on a Dell Latitude E6420 and just installed 12.04. When I plug in my external monitor's VGA cable, the laptop doesn't detect any new monitor. Here's the output of my lspci: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:16.3 Serial controller: Intel Corporation 6 Series/C200 Series Chipset Family KT Controller (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579LM Gigabit Network Connection (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b4) 00:1c.1 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 2 (rev b4) 00:1c.2 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 3 (rev b4) 00:1c.3 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 (rev b4) 00:1c.5 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 6 (rev b4) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation QM67 Express Chipset Family LPC Controller (rev 04) 00:1f.2 RAID bus controller: Intel Corporation 82801 Mobile SATA Controller [RAID mode] (rev 04) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation GF119 [Quadro NVS 4200M] (rev a1) 01:00.1 Audio device: NVIDIA Corporation HDMI Audio stub (rev a1) 03:00.0 Network controller: Intel Corporation Centrino Advanced-N 6205 (rev 34) 0b:00.0 SD Host controller: O2 Micro, Inc. Device 8221 (rev 05) 0b:00.1 Mass storage controller: O2 Micro, Inc. Device 8231 (rev 03) I tried installing the Quadro NVS 4200M from the nvidia website but got stuck in TTY after the installation finished. Any ideas as to how I can get the external monitor to work? Thanks!

    Read the article

  • A bounce-rate attack to manipulate SEO ?

    - by Denis Volovik
    This is a question to experienced people that might help us shed some light on the issue. We noticed a very strange behavior on our site, in Google Analytics. Some dude from Finland, namely, from Kouvola city is hitting one of our pages - only one page on our site, 'bout a hundred times per day, all with an average bounce rate of 90%+... This is causing our overall bounce rate to go up by 1 to 3% per day... which is very disturbing.. since we're trying to do our best in order to keep it as low as possible. And obviously having it jumped from ~24% to 27%, just because of that crazy dude is not making us happy at all... We tried implementing a geo-targeted script in order to catch this particular visitor and deliver him a juicy message, and it seemed like it helped in the beginning, it has stopped for a day or two, but now he's back... The geo-targeted script was also logging all IP addresses for page requests originating from Finland in order to find out more details and (in order to block them on the server level, later).. but thing is, it was all mainly cable or DSL connections with various, but not constantly repeating IPs... we are all wondering what is he up to really ? I think that this page should be kept updated with ideas on how to combat this and perhaps someone could also shed light on what it might be ? What is the reason for doing this "bounce-rate attack", as I call it? There was a similar question asked on stackoverflow earlier, with no meaningful answer - here - How to stop bounce rate manipulation.

    Read the article

  • make my Ubuntu 12.04 laptop visible on the network

    - by Andrew Boyd
    I'm ecstatically happy with my 12.04 on my laptop after loading it over my MS Vista... but there's just one thing, one little fly in the ointment.... While I can view our 2 Terabyte, shared hard-drive in the lounge (and copy files back and forth) I can't see my PC (when I boot up in Ubuntu 12.04) nor the Lubuntu computer connected to the TV (for movies, Youtube etc). Printing to the HP office jet on the PC doesnt work over the network either. Have had one dubious flirtation with Samba, which seems to be the only thing I've found that will 'work', however halfway through that "installation" everything just ground to a halt, the directions began to stop making sense... I was working from this page. Our Network consists of the following: Our Internet service is wirelessly sent to us from our provider to our dish on a pole. It comes into the house via an ethernet cable. We split it there to a phone, and to 6 other destinations (bedrooms, computers, and to another splitter in the lounge which has a wifi antennae and 4 ethernet ports). one port goes to the Lubuntu OS PC which is connected to the TV the second port goes to the 2 Terabyte harddrive (MS powered 'Mybooklive') (the other two are empty) My Ubuntu 12.04 laptop connects wirelessly to this splitter in the lounge. I know just enough about computers to get myself into an awful mess without too much trouble We usually can view friends' laptops when they get on our network (as they are invariably MS OS's) Our flatmate, who introduced us to Linux's computer is also invisible How can we make our Linux OS based computers visible on the network and share files and printing?

    Read the article

  • What would cause SSD to become not detectable?

    - by Balthazar
    I recently purchased an Intel 520 120GB SSD and installed Ubuntu on it. Occasionally my system will freeze and I will have to ALT-PRINT SCREEN-REISUB to reboot. Sometimes it will reboot and work just fine. Other times it just hangs at a flashing prompt. If I boot from a Live USB I can run Boot-Repair and it will usually reboot fine the next go round. I have noticed today that when I am running the live USB and open Nautilus my SSD partitions will sporadically disappear and reappear. Even if they are mounted. I was thinking it was a poor connection, but I have tried a different SATA cable and a different SATA port. Is it possible I have a faulty SSD, or is there something different you have to do with SSDs to make sure they stay mounted (I was thinking like it has some sort of goofy power savings feature that needs to be disabled). I found the place in the bios where the SATA ports are listed. They are all set to AHCI(Chipset - SATA Mode = AHCI) The unmounting/remounting happens all the time. I think this is the relevant part of the syslog: http://pastebin.com/WxHdRAAq

    Read the article

  • Suspending my laptop breaks ethernet over firewire, are there commands which can fix it?

    - by Josh
    As mentioned in this question I am using a firewire cable to provide a private network between my laptop and my desktop, because it makes using the screen sharing program synergy much nicer than using WIFI. However when I leave my office for the day and I suspend my laptop, when I return the next day, the desktop and the laptop cannot communicate over firewire anymore. The firewire0 device still has an IP address. but when I try and ping the desktop I get no route to host I'm using kernel 2.6.35-24-generic #42-Ubuntu SMP x86_64 on Ubuntu 10.10. Is there some way I can remedy this without a reboot? Like, removing some kernel modules and re-inserting them? Here's what I have tried so far and the results: root@token:~# dmesg|tail -n 1 [592525.204024] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 root@token:~# modprobe -r firewire_net firewire_ohci firewire_core root@token:~# modprobe -v firewire_ohci insmod /lib/modules/2.6.35-24-generic/kernel/lib/crc-itu-t.ko insmod /lib/modules/2.6.35-24-generic/kernel/drivers/firewire/firewire-core.ko insmod /lib/modules/2.6.35-24-generic/kernel/drivers/firewire/firewire-ohci.ko root@token:~# dmesg|tail [592525.204024] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [592563.410868] firewire_ohci: Removed fw-ohci device. [592579.160086] firewire_ohci: Added fw-ohci device 0000:02:00.0, OHCI v1.10, 4 IR + 8 IT contexts, quirks 0x2 [592579.160137] firewire_ohci: isochronous cycle inconsistent [592579.660294] firewire_core: created device fw0: GUID 0000000000000000, S400 [592579.663805] firewire_core: created device fw1: GUID 0017f2fffe89bce6, S400 [592579.663813] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [592579.700720] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [592579.700842] firewire_core: refreshed device fw0 [592579.702603] firewire_net: firewire0: IPv4 over FireWire on device 0000000000000000 root@token:~# ping stan.firewire PING stan.firewire (192.168.100.1) 56(84) bytes of data. From token.local (192.168.100.3) icmp_seq=1 Destination Host Unreachable From token.local (192.168.100.3) icmp_seq=2 Destination Host Unreachable From token.local (192.168.100.3) icmp_seq=3 Destination Host Unreachable I also tried removing the modules prior to suspending, and re-inserting after resuming. This did not work either :-(

    Read the article

  • Ubuntu 12.04 LTS , Dell d410 output to External Monitor/TV with docking

    - by Gck
    I am not able to see the video output on My external monitor/TV after installing 12.04 LTS. I had the same issue with 11 versions also. This issue does not happen on 10.04 LTS version. This is my setup. Dell latitude D410 with Intel Mobile 915 GM/910GML express controller using the Dell docking station Connecting to my 42inch TV with DVI (from Docking) to HDMI cable (on TV) If i close the lid, some times i am able to see the video output on TV, but the resolution is making the fonts so small, i cannot even see it and when i click displays option to change the resolution, the output goes off completely and it is shown now on the laptop screen. one time, i got the output on both the screens, but i am not able to replicate that scenario even after trying the Fn+F8 key option on my laptop. earlier some time back when i ran version 11.x ubuntu, i was able to get the output on both the screens (basically mirrored output) with large font resolution on my TV using the monitor Test tool as mentioned here :http://www.bigfatostrich.com/2011/05/solved-ubuntu-11-04-broken-external-display/ The problem with this approach is that i have to do it every time i restart the machine and more over the video output is present on both the screens (mirrored), which is of no use. As i stated before, this does not happen with 10.04 LTS. With 10.04 LTS my laptop screen is off automatically and the output is seen on TV/external display. Can anyone share any options that i can try? How can we achieve the behavior of 10.04 LTS with respect to the External display on 12.04 LTS . Thankyou very much for your help in advance.

    Read the article

  • SMART Status Data Interpretation - Disk Utility

    - by Mah
    Last week my external harddisk (Seagate Barracuda 1.5TB in a custom enclosure) showed signs of failure (Disk Utility SMART Pre-failure status - several bad sectors) and I decided to change it. I bought a new HDD (Seagate Barracuda 2TB) and connected it to my Ubuntu box with a SATA to USB cable that could not report SMART status. I copied all the contents of the old HDD to the new HDD (one partition with rsync, the other with parted cp) and then gently replaced the old HDD with the new one inside my aluminum enclosure. For obscure reasons after reconnecting the new HDD through the old enclosure, the Linux box could not detect my partitions. I recovered the partitions with testdisk and restarted the computer. After the restart I checked the SMART status of the new HDD an I get this: Read Error Rate --------------- Normalized 108 Worst 99 Threshold 6 Value 16737944 I got a high value on the Seek Error Rate as well. Wondering why this happens I copied 2 GB directory from one partition to the other and rechecked the SMART status (5 minutes later). This time I got the following: Read Error Rate --------------- Normalized 109 Worst 99 Threshold 6 Value 24792504 As you see there has been an increase in the error rate. I am unable to interpret these numbers. Is my new hard disk already dying? What are the acceptable values in these fields for Seagate hard disks? Then why the assessment is still good? While I could get temperature and airflow temperature data from my old HDD, I can not fetch them for the new one. I noticed that my old hdd had got really hot sometimes. Is it possible that the enclosure is killing the harddisks due to high temperature?... Thanks

    Read the article

  • no way to use opendns on pppoe connection?

    - by magisterludi
    I have an old speedtouch usb modem (revision 0) and on my desktop with xubuntu 12.04 I've configured a pppoe connection. I can connect and my ISP assign an IP address and the DNS but the primary DNS address is not reachable by ping, the secondary yes but no address is resolved then I can't surf the web. Then I want to set the open DNS but there is bo way, if I change manually /etc/resolv.conf it is rewrited by some script (there is the flag usepeerdns on the configuration script, if I exclude it there is no way to assign any DNS server because resolv.conf is not read) also if I set not writable the file changing the default permission. I changed dhclient.conf with the code prepend domain-name-servers 208.67.222.222,208.67.220.220; and now if I connect by a wifi connection to my router I'm using openDNS server but ppp does not use this script as long as I can see and the DNS server is always setted by my ISP. How can I use set DNS manually to a PPP connection? Is there any way to change it after the connection? Why NetworkManager is not able to manage my dsl connection, it seems not able to manage the dsl usb cable modem. If I use pppoeconf NetworkManager doesn't start and I have to manually delete the lines added to /etc/network/interfaces because the system is not able to start with full configuration of network If I connect a modem-router to the same line I can surf with the DNS server assigned by my ISP, I can't figure why. Some suggestion? Thanks to all

    Read the article

  • How do I get OBDII software working?

    - by NoBugs
    I have an ODBII USB cable for vehicle diagnostics, unfortunately I haven't been able to get it working on Ubuntu 12.04. The closest I've come is using the VAG-COM software with wine, using the ln -s /dev/ttyUSB0 ~/.wine/dosdevices/com1 trick and running stty -F /dev/ttyUSB0 speed 9600 repeatedly. It will connect and show the vehicle is OBDII, but none of the useful features seem to be working. I tried: Scantool - says it's connecting to the /dev/device in terminal, but doesn't. obdgpslogger - times out all the time. pyobd - This seems to be the most up-to-date source I could find, I had to adjust the code a bit to work (see here for changes). Still, in obd_io.py interpret_result function, it says it's looking for 4 space separated numbers, where the usb-serial is receiving bogus code "0100" instead? The device shows up in lsusb as: ID 0403:6001 Future Technology Devices International, Ltd FT232 USB-Serial (UART) IC Is the problem that these native tools don't expect a USB serial, or a serial of this type? Or are these apps too old to recognize OBD2 of this vehicle?

    Read the article

  • The Other "C" in CRM

    - by [email protected]
    By Brian Dayton on April 5, 2010 7:04 PM Folks who know me know that I rarely, if ever, talk politics. And I never talk politicians. Having grown up in a household with one parent leaning left and the other leaning to the right it was the best way to keep the peace. This isn't about politics. It's about "constituents" and the need to improve the services and service levels for people--at the city, county, state/province, etc. level all the way up to national governments. As a citizen and tax payer it's also important to me that these services be provided at a reasonable cost. If there's a better and more efficient way to do something then it's my hope that a public sector organization takes advantage of technology the same way private sector companies do. Social services organizations have a complex job. They provide the services that people need, from healthcare and children's assistance to helping people find jobs. But many of these organizations are still managing these processes manually or outdated, home-grown applications that could have been written up to 30 years ago. A lot has changed in technology. On the (this is as political as I'm going to get) political front, stakeholders like you and me are expecting greater transparency on where and how funds are spent. I'll admit that most of the time, when I think about CRM systems, I think about my experience as a customer of my bank, utilities company or cable operator. But now that I'm older, have children and a house--I find myself interacting more and more with agencies and services organizations. My experiences are sometimes good and sometimes not so good. Along those lines, last week's announcement of Siebel CRM 8.2 for Public Sector caught my eye. You may not work in the public sector, but you are a constituent of some--actually a lot--of public sector organizations. I don't know which CRM systems city and county utilize but I'm going to start paying closer attention.

    Read the article

  • Have to run sudo dhclient eth0 automatically every boot

    - by Fyksen
    I just installed ubuntu 12.04.1 alternative install (for raid 0 on some disks). I Have some problems with the net. I'm at school, we use cable, and it got IPv6. If I run ifconfig eth0 heres my output: eth0 Link encap:Ethernet HWaddr e0:cb:4e:87:ff:db inet addr:128.39.194.217 Bcast:128.39.194.223 Mask:255.255.255.224 inet6 addr: 2001:700:1100:8008:e2cb:4eff:fe87:ffdb/64 Scope:Global inet6 addr: fe80::e2cb:4eff:fe87:ffdb/64 Scope:Link inet6 addr: 2001:700:1100:8008:48f7:c23:1d87:da6c/64 Scope:Global UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1063378 errors:0 dropped:0 overruns:0 frame:0 TX packets:489811 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:1577173461 (1.5 GB) TX bytes:37043669 (37.0 MB) Interrupt:68 Base address:0x6000 My /etc/network/interfaces look like this: # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 # NetworkManager#iface eth0 inet dhcp # NetworkManager#hostname 2001:700:1100:1::4 # This is an autoconfigured IPv6 interface iface eth0 inet6 auto (I had to remove the hash tags, because of the BIGFONT i get on ask ubuntu) The "network manager" says that I'm not connected. Let me know if you need any more information. :)

    Read the article

  • apt-get update very slow, stuck at "Waiting for headers"

    - by Liam
    I have looked at similar questions: Stuck at 0% [waiting for headers] (apt) apt-get update stuck on "Waiting for Headers" However neither one of them answer my problem. I am running 12.04 AMD64 and have recently started getting an issue that when I update my repos from my connection at home through a terminal, using sudo apt-get update, it takes forever (literally after 2 hours it was at 28%), however when I run from a different location it takes less than 5 minutes to complete. I have attempted changing which mirror I use but that does not solve the issue. I have also cut down what is in my sources list but this also makes no difference. There are no faults on my ADSL line as I have already contacted my ISP to check this. It also makes no difference if I use a WiFi or network cable connection. What could be my issue? A speed test (www.speedtest.net) comes out at about 0.9 Mbps down and 0.42 Mbps up (which is a shade under the advertised line speed), I reside in South Africa and use the UCT LEG server. But I have also tried the other mirrors available in SA....none of them make a difference.

    Read the article

  • dell vostro 1000 broadcom wireless connection

    - by lorrenuy
    I have a problem with the hardware broadcom wifi. I press the hotkey fn+f2 to activate the hardware and this will not work. I'll look at the drivers but it appears to be installed. How can I solve this problem? Ubuntu is all new to me so if possible, give me a clear explanation. Now do I connect the lan cable. I use the Ubuntu 11.10 lawrence@lawrence-Vostro-1000:~$ sudo lshw -class network [sudo] password for lawrence: PCI (sysfs) *-network description: Network controller product: BCM4311 802.11b/g WLAN vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:05:00.0 version: 01 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=b43-pci-bridge latency=0 resources: irq:18 memory:c0200000-c0203fff *-network description: Ethernet interface product: BCM4401-B0 100Base-TX vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:08:00.0 logical name: eth1 version: 02 serial: 00:1c:23:a2:b9:a9 size: 100Mbit/s capacity: 100Mbit/s width: 32 bits clock: 33MHz capabilities: pm bus_master cap_list ethernet physical mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=b44 driverversion=2.0 duplex=full ip=192.168.1.18 latency=64 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:21 memory:c0300000-c0301fff lawrence@lawrence-Vostro-1000:~$ lawrence@lawrence-Vostro-1000:~$ rfkill list all 0: dell-wifi: Wireless LAN Soft blocked: yes Hard blocked: yes

    Read the article

  • /etc/resolv.conf nameserver fd00::1

    - by user88631
    My /etc/resolv.conf constantly get a mysterious entry, i run a home network with ipv6 provided by ravd, the interface is auto-configured by Network manager (all name server lookups are lost when this line is first in my /etc/resolv.conf) . Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) **# DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN** nameserver fd00::1 nameserver 192.168.1.1 search home.int When ping is working cat /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 192.168.1.1 search home.int So something is putting fd00::1 at start of file, not if I ping6 fd00::1 I get Destination unreachable: Administratively prohibited To diagnose this I ran the router with single cable to connected to ubuntu machine. Ran tcpdump + restarted network on ubuntu. "tcpdump ip6 -e -i eth0 | grep fd00" finds nothing, it's not being advertised via the network.. The only hit I got was when an upstream router refused a connection attempt from the ubuntu machine to fd00::1. I have also switched on debug for network manager & it appears to set the mystery line.. 15:22:14 storage-pc NetworkManager[349]: <info> Activation (eth0) Stage 5 of 5 (IPv4 Commit) complete. 15:22:14 storage-pc NetworkManager[349]: <warn> dnsmasq exited with error: Other problem (5) 15:22:14 storage-pc NetworkManager[349]: <debug> [1346822534.281528] [nm-dns-manager.c:598] update_dns(): updating resolv.conf 15:22:14 storage-pc NetworkManager[349]: <debug> [1346822534.281875] [nm-dns-manager.c:719] update_dns(): DNS: plugin dnsmasq ignored (caching disabled) 15:22:14 storage-pc NetworkManager[349]: <info> ((null)): writing resolv.conf to /sbin/resolvconf 15:22:14 storage-pc dbus[2184]: [system] Successfully activated service 'org.freedesktop.nm_dispatcher' 15:22:14 storage-pc dnsmasq[2875]: reading /etc/resolv.conf 15:22:14 storage-pc dnsmasq[2875]: using nameserver 192.168.1.1#53 15:22:14 storage-pc dnsmasq[2875]: using nameserver fd00::1#53 Any suggestions on how to find out where this comes from?

    Read the article

  • Why does Ubuntu keep trying to connect to a WiFi network while plugged into an ethernet

    - by labarna
    My desk is situated at the edge of the range of a wireless signal which I use occasionally (when away from my desk) and is therefore saved in network manager. At my desk, however, I plug into the ethernet cable. While I'm working the computer is constantly trying to join the wireless network and usually failing this results in two annoying behaviors. 1: In gnome shell the network connect and disconnect notices keep popping up at the bottom of the screen and I have to click them to make them disappear (I assume it's been fixed in the next version of gnome). 2: (the worst!) Occasionally the wifi password dialog will pop up and ask for the password to this network (which is already saved). An additionally annoyance is that in gnome shell I'll get two copies of the dialog that I have to cancel, one is gnome shell themed (no window border etc...) and the other is just normal gnome themed. (Sometimes if I've been away from the computer for a while I will have multiple copies of this dialog up as its been trying to connect for a while resulting in at times 20 dialogs to cancel). Note, all the while I've been happily connected to the ethernet and have full network access. This is incredibly annoying and distracting, why doesn't ubuntu stop trying to connect to wifi if I'm on the ethernet (unless I want to broadcast my own network, but that's different)?

    Read the article

  • Multiple monitors showing same screen but different resolutions

    - by Luis Alvarado
    Is it possible to have 2 or more monitors showing the same screen, for example the same desktop but with different resolutions. Like the clone option in Nvidia or the mirror option using the Display settings in Ubuntu but instead of showing the same output with the same resolution, the both show the same output using a resolution that is native for each monitor connected. In my case if I have a netbook that has max resolution of 1360x768 and a TV that has 1280x1024, the would both show the same desktop but each with their own resolution that is compatible for each device. This would help in trying to find a resolution that works on both monitors and in cases like a mini netbook and a huge TV it would solve issues like having max 800x600 in one monitor and min 1024x768 in the other. In the case I tested I was using an HDMI cable but this question also involves VGA and any other connection. I have 3 tests scenarios for this: Scenario 1 - Laptop HP DV6000 (Intel Integrated Video) with 1360x760 connected to a Samsung LED 42 TV that has 1280x900. Scenario 2 - Laptop EEE with 1024x600 (Intel Integrated Video) connected to Sony LCD TV that supports 1280x900. Scenario 3 - Intel Desktop with Nvidia 440 GT with HDMI connected to Soneview 32' TV that supports 1920x1080 and VGA connected to an Epson Video Beam that supports 1280x1024 max. In this 3 scenarios I need to be able to show the same desktop and same views but on different resolutions for each output device. UPDATE: Tested with Xubuntu and the way it handles multiple monitors is precisely what I am asking. The ability to handle the resolution of different monitors showing the same thing.

    Read the article

  • Ubuntu 12.04 Server ping gateway responds with destination host unreachable

    - by blckblttkd
    I consider myself fairly avid with Ubuntu and Linux, but this one has me stumped. I built up a Xen Server using Ubuntu 12.04 as the base operating system. It has multiple domUs running on it. My home network has a statically defined network where I got all the network connectivity going peachy. The server was moved to a permanent home this morning. So, the network configuration on the main system had to change. Again, another static network, but now I can't ping the upstream gateway from the host. As the VMs use this NIC over a bridge, they too are broken. Ping responds with "destination host unreachable." I simplified the networking down to a simple static network as seen below (no bridge or anything) just to get it to work. Here's the contents of my /etc/network/interfaces file: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 216.7.188.228 gateway 216.7.188.225 netmask 255.255.255.240 broadcast 216.7.188.255 network 216.7.188.0 dns-nameservers 8.8.8.8 8.8.4.4 Here's the contents of route -n 0.0.0.0 216.7.188.225 0.0.0.0 UG 100 0 0 eth0 216.7.188.224 0.0.0.0 255.255.255.240 U 0 0 0 eth0 And the results of pinging the gateway: PING 216.7.188.225 (216.7.188.225) 56(84) bytes of data. From 216.7.188.228 icmp_seq=1 Destination Host Unreachable From 216.7.188.228 icmp_seq=1 Destination Host Unreachable From 216.7.188.228 icmp_seq=1 Destination Host Unreachable Again, this worked in one network flawlessly (obviously with different parameters in the interfaces file). I did try using eth1 (as there are two NICS on the server (in case the MAC address got flipped on bootup). No success there. Yes, the cable is in the right port now :) Any thoughts? I appreciate the help!

    Read the article

  • Managing Kindle Fire with on 12.04 via Micro-USB

    - by pirtle
    To begin, I have read both Is there a way to get a Kindle Fire to work with 12.04? and How can I transfer files to a Kindle Fire with a Micro-USB cable? My problem is that I am unable to mount my Kindle Fire in order to add books to it. I have installed calibre, but it is unable to manage any devices until the computer itself has recognized it. The latter post had an excellent answer (provided by @jeremiah) that was making some progress. Unfortunately, I think I don't know enough about the -t flag used with mount. This is what I've done... Ran dmesg to locate the device: [ 3.920886] sd 6:0:0:0: [sdb] Attached SCSI removable disk Confirmed it's location: $ sudo ls -l /dev/disk/by-id lrwxrwxrwx 1 root root 9 Aug 18 15:52 usb-Amazon_Kindle_3C6C002600000001-0:0 -> ../../sdb So we know that my Kindle is recognized on /dev/sdb. I then used the mount command suggested by @jeremiah: $ sudo mount -t ext3 /dev/sdb/ /mnt/kindle/ mount: no medium found on /dev/sdb The same error occurs for sudo mount /dev/sdb /mnt/kindle. Note: I have created the 'kindle' directory in 'mnt' Any suggestions?

    Read the article

< Previous Page | 528 529 530 531 532 533 534 535 536 537 538 539  | Next Page >