  • squid3 auth thru samba using ntlm to AD doesn't work

    - by derty
    some users here are spending to much time exploring the WWW. So big boss whats to get this under control. We use a squid3 just for some security reason and chace benefits. and now i'm trying to set up a new proxy on a different server (Debian 6) Permissions are defined in AC and the squid3 should get the auth thru samba/winbind by using the ntlm protocol. but i'll get all the time Access, denited. it only works by using LDAP but thats not the way i need it. here some log and confs squid access.log 1326878095.784 1 192.168.15.27 TCP_DENIED/407 4049 GET http://at.msn.com/? -NONE/- text/html 1326878095.791 1 192.168.15.27 TCP_DENIED/407 4294 GET http://at.msn.com/? - NONE/- text/html 1326878095.803 9 192.168.15.27 TCP_DENIED/403 4028 GET http://at.msn.com/? kavan NONE/- text/html 1326878095.848 0 192.168.15.27 TCP_DENIED/403 3881 GET http://www.squid-cache.org/Artwork/SN.png kavan NONE/- text/html 1326878100.279 0 192.168.15.27 TCP_DENIED/403 3735 GET http://www.google.at/ kavan NONE/- text/html 1326878100.296 0 192.168.15.27 TCP_DENIED/403 3870 GET http://www.squid-cache.org/Artwork/SN.png kavan NONE/- text/html 1326878155.700 0 192.168.15.27 TCP_DENIED/407 4072 GET http://ie9cvlist.ie.microsoft.com/IE9CompatViewList.xml - NONE/- text/html 1326878155.705 2 192.168.15.27 TCP_DENIED/407 4317 GET http://ie9cvlist.ie.microsoft.com/IE9CompatViewList.xml - NONE/- text/html 1326878155.709 3 192.168.15.27 TCP_DENIED/403 4026 GET http://ie9cvlist.ie.microsoft.com/IE9CompatViewList.xml kavan NONE/- text/html squid chace 2012/01/18 10:12:49| Creating Swap Directories 2012/01/18 10:12:49| Starting Squid Cache version 3.1.6 for x86_64-pc-linux-gnu... 2012/01/18 10:12:49| Process ID 17236 2012/01/18 10:12:49| With 65535 file descriptors available 2012/01/18 10:12:49| Initializing IP Cache... 2012/01/18 10:12:49| DNS Socket created at [::], FD 7 2012/01/18 10:12:49| DNS Socket created at 0.0.0.0, FD 8 2012/01/18 10:12:49| Adding nameserver 192.168.15.2 from /etc/resolv.conf 2012/01/18 10:12:49| Adding nameserver 192.168.15.19 from /etc/resolv.conf 2012/01/18 10:12:49| Adding nameserver 192.168.15.1 from /etc/resolv.conf 2012/01/18 10:12:49| Adding domain schoenbrunn.local from /etc/resolv.conf 2012/01/18 10:12:49| helperOpenServers: Starting 5/5 'squid_ldap_auth' processes 2012/01/18 10:12:49| helperOpenServers: Starting 10/10 'ntlm_auth' processes 2012/01/18 10:12:49| helperOpenServers: Starting 10/10 'squid_kerb_auth' processes 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| helperOpenServers: Starting 5/5 'squid_ldap_group' processes 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| squid_kerb_auth: INFO: Starting version 1.0.5 2012/01/18 10:12:49| Unlinkd pipe opened on FD 73 2012/01/18 10:12:49| Local cache digest enabled; rebuild/rewrite every 3600/3600 sec 2012/01/18 10:12:49| Store logging disabled 2012/01/18 10:12:49| Swap maxSize 0 + 262144 KB, estimated 20164 objects 2012/01/18 10:12:49| Target number of buckets: 1008 2012/01/18 10:12:49| Using 8192 Store buckets 2012/01/18 10:12:49| Max Mem size: 262144 KB 2012/01/18 10:12:49| Max Swap size: 0 KB 2012/01/18 10:12:49| Using Least Load store dir selection 2012/01/18 10:12:49| Set Current Directory to /var/spool/squid3 2012/01/18 10:12:49| Loaded Icons. 2012/01/18 10:12:49| Accepting HTTP connections at [::]:3128, FD 74. 2012/01/18 10:12:49| HTCP Disabled. 2012/01/18 10:12:49| Squid modules loaded: 0 2012/01/18 10:12:49| Adaptation support is off. 2012/01/18 10:12:49| Ready to serve requests. 2012/01/18 10:12:50| storeLateRelease: released 0 objects smb.conf # Domain Authntication Settings workgroup = <WORKGROUP> security = ads password server = <DOMAINNAME>.LOCAL realm = <DOMAINNAME>.LOCAL ldap ssl = no # logging log level = 5 max log size = 50 # logs split per machine log file = /var/log/samba/%m.log # max 50KB per log file, then rotate ; max log size = 50 # User settings username map = /etc/samba/smbusers idmap uid = 10000-20000000 idmap gid = 10000-20000000 idmap backend = ad ; template primary group = <ad group> template shell = /sbin/nologin # Winbind Settings winbind separator = + winbind enum users = Yes winbind enum groups = Yes winbind netsted groups = Yes winbind nested groups = Yes winbind cache time = 10 winbind use default domain = Yes #Other Globals unix charset = LOCALE server string = <SERVERNAME> load printers = no printing = cups cups options = raw ; printcap name = /etc/printcap #obtain list of printers automatically on SystemV ; printcap name = lpstat ; printing = cups squid.conf auth_param ntlm program /usr/bin/ntlm_auth --require-membership-of=<DOMAINNAME>\\INTERNETZ --helper-protocol=squid-2.5-ntlmssp auth_param ntlm children 10 auth_param basic program /usr/lib/squid3/squid_ldap_auth -R -b "dc=<dcname>,dc=local" -D "cn=administrator,cn=Users,dc=<domainname>,dc=local" -w "******" -f sAMAccountName=%s -h 192.168.15.19:3268 auth_param basic realm "Proxy Authentifizierung. Bitte geben Sie Ihren Benutzername und Ihr Passwort ein!" #means insert you PW in an other language - # external_acl_type InetGroup %LOGIN /usr/lib/squid3/squid_ldap_group -R -b "dc=<domainname>,dc=local" -D "cn=administrator,cn=Users,dc=<domainname>,dc=local" -w "******" -f "(&(objectclass=person)(sAMAccountName=%v) (memberof=cn=%a,cn=internetz,dc=<domainname>,dc=local))" -h 192.168.15.19:3268 auth_param negotiate program /usr/lib/squid3/squid_kerb_auth -d auth_param negotiate children 10 auth_param negotiate keep_alive on acl localnet proxy_auth REQUIRED acl InetAccess external InetGroup Internetz http_access allow InetAccess http_access deny all acl auth proxy_auth REQUIRED http_access allow auth and a very suspicious is that by adding the proxy server to the Domain i see 2 new entries in the PC one with the original computer-name leopoldine and one with leopoldine CNF:f8efa4c4-ff0e-4217-939d-f1523b43464d ?!? I tried a lot, really... but i stuck on this problem... i actually i even reinstalled all dependent programs and reconfigured them from default. Group exists and has me in it. Firefox running on the old proxy and i use IE for testing the new one. But i'll get all the time Access-Denited and to be honest i'm quite a beginner, so please don't be to prude. I'll interested in improving, i'll get the information we need to fix this but i started working 2 month ago and got only 1 1/2 year's training and not a single sec. in linux ;)

    Read the article

  • DNS Problems (NIGHTMARES!) with BIND and Virtualmin

    - by Nyxynyx
    I have a webserver (Ubuntu 12.04 with LAMP) using Virtualmin / Webmin. Because I just moved from a Cpanel system, I am having a nightmare configuring the DNS! Using intoDNS.com, the failed reports are: Mismatched NS records WARNING: One or more of your nameservers did not return any of your NS records. DNS servers responded ERROR: One or more of your nameservers did not respond: The ones that did not respond are: 123.123.123.123 213.251.188.141x Multiple Nameservers ERROR: Looks like you have less than 2 nameservers. According to RFC2182 section 5 you must have at least 3 nameservers, and no more than 7. Having 2 nameservers is also ok by me. Missing nameservers reported by your nameserver You should already know that your NS records at your nameservers are missing, so here it is again: ns1.mydomain.com. sdns2.ovh.net. SOA record No valid SOA record came back! MX Records WWW A Record ERROR: I could not get any A records for www.mydomain.com! Step-by-Step of my Attempt In my domain registrar (Namecheap), I registered ns1.mydomain.com as a nameserver, pointing to the IP address of my web server which is running bind9. The domain is setup with DNS ns1.mydomain.com and sdns2.ovh.net. sdns2.ovh.net is a secondary DNS server (SLAVE and pointing mydomain.com to the IP address of my web server) Webserver domain: mydomain.com Webserver hostname: ns4000000.ip-123-123-123.net Webserver IP: 123.123.123.123 Under Virtualmin, I edited the default Virtual server template, BIND DNS records for new domains: ns1.mydomain.com Master DNS server hostname: ns1.mydomain.com Next I created a Virtual server using that server template. This is what I've done but its still not working! Any ideas? I've been stuck for days, thank you for all your help! service bind9 status * bind9 is running lsof -i :53 COMMAND PID USER FD TYPE DEVICE SIZE/OFF NODE NAME named 6966 bind 20u IPv6 338583 0t0 TCP *:domain (LISTEN) named 6966 bind 21u IPv4 338588 0t0 TCP localhost.localdomain:domain (LISTEN) named 6966 bind 22u IPv4 338590 0t0 TCP ns4000000.ip-123-123-123.net:domain (LISTEN) named 6966 bind 512u IPv6 338582 0t0 UDP *:domain named 6966 bind 513u IPv4 338587 0t0 UDP localhost.localdomain:domain named 6966 bind 514u IPv4 338589 0t0 UDP ns4000000.ip-123-123-123.net:domain /etc/resolv.con (Not sure how 213.186.33.99 got here) nameserver 127.0.0.1 nameserver 213.186.33.99 search ovh.net host 123.123.123.123 (my web server's IP) 13.60.245.198.in-addr.arpa domain name pointer ns4000000.ip-123-123-123.net. nslookup 213.186.33.99 Server: 127.0.0.1 Address: 127.0.0.1#53 Non-authoritative answer: 99.33.186.213.in-addr.arpa name = cdns.ovh.net. Authoritative answers can be found from: 33.186.213.in-addr.arpa nameserver = ns.ovh.net. 33.186.213.in-addr.arpa nameserver = dns.ovh.net. nslookup ns1.mydomain.com ;; Got SERVFAIL reply from 127.0.0.1, trying next server ;; connection timed out; no servers could be reached nslookup ns2.mydomain.com ;; Got SERVFAIL reply from 127.0.0.1, trying next server ;; connection timed out; no servers could be reached nslookup www.mydomain.com ;; Got SERVFAIL reply from 127.0.0.1, trying next server ;; connection timed out; no servers could be reached dig mydomain.com ; <<>> DiG 9.8.1-P1 <<>> mydomain.com ;; global options: +cmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: SERVFAIL, id: 43540 ;; flags: qr rd ra; QUERY: 1, ANSWER: 0, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;mydomain.com. IN A ;; Query time: 0 msec ;; SERVER: 127.0.0.1#53(127.0.0.1) ;; WHEN: Thu Oct 11 11:30:09 2012 ;; MSG SIZE rcvd: 30 dig ns1.mydomain.com ; <<>> DiG 9.8.1-P1 <<>> ns1.mydomain.com ;; global options: +cmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: SERVFAIL, id: 31254 ;; flags: qr rd ra; QUERY: 1, ANSWER: 0, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;ns1.mydomain.com. IN A ;; Query time: 0 msec ;; SERVER: 127.0.0.1#53(127.0.0.1) ;; WHEN: Thu Oct 11 11:30:16 2012 ;; MSG SIZE rcvd: 34 /etc/bind/named.conf include "/etc/bind/named.conf.options"; include "/etc/bind/named.conf.local"; include "/etc/bind/named.conf.default-zones"; /etc/bind/named.conf.default-zones zone "." { type hint; file "/etc/bind/db.root"; }; zone "localhost" { type master; file "/etc/bind/db.local"; }; zone "127.in-addr.arpa" { type master; file "/etc/bind/db.127"; }; zone "0.in-addr.arpa" { type master; file "/etc/bind/db.0"; }; zone "255.in-addr.arpa" { type master; file "/etc/bind/db.255"; }; /etc/bind/named.conf.local zone "mydomain.com" { type master; file "/var/lib/bind/mydomain.com.hosts"; allow-transfer { 127.0.0.1; localnets; }; }; /etc/bind/named.conf.options options { directory "/var/cache/bind"; dnssec-validation auto; auth-nxdomain no; # conform to RFC1035 listen-on-v6 { any; }; // allow-recursion { 127.0.0.1; }; // transfer-source; }; named-checkconf -z dns_master_load: /var/lib/bind/mydomain.com.hosts:21: unexpected end of line dns_master_load: /var/lib/bind/mydomain.com.hosts:20: unexpected end of input /var/lib/bind/mydomain.com.hosts: file does not end with newline zone mydomain.com/IN: loading from master file /var/lib/bind/mydomain.com.hosts failed: unexpected end of input zone mydomain.com/IN: not loaded due to errors. _default/mydomain.com/IN: unexpected end of input zone localhost/IN: loaded serial 2 zone 127.in-addr.arpa/IN: loaded serial 1 zone 0.in-addr.arpa/IN: loaded serial 1 zone 255.in-addr.arpa/IN: loaded serial 1 iptables -L Chain INPUT (policy ACCEPT) target prot opt source destination ACCEPT udp -- anywhere anywhere udp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:20000 ACCEPT tcp -- anywhere anywhere tcp dpt:webmin ACCEPT tcp -- anywhere anywhere tcp dpt:https ACCEPT tcp -- anywhere anywhere tcp dpt:http ACCEPT tcp -- anywhere anywhere tcp dpt:imaps ACCEPT tcp -- anywhere anywhere tcp dpt:imap2 ACCEPT tcp -- anywhere anywhere tcp dpt:pop3s ACCEPT tcp -- anywhere anywhere tcp dpt:pop3 ACCEPT tcp -- anywhere anywhere tcp dpt:ftp-data ACCEPT tcp -- anywhere anywhere tcp dpt:ftp ACCEPT tcp -- anywhere anywhere tcp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:submission ACCEPT tcp -- anywhere anywhere tcp dpt:smtp ACCEPT tcp -- anywhere anywhere tcp dpt:ssh ACCEPT all -- anywhere anywhere Chain FORWARD (policy ACCEPT) target prot opt source destination Chain OUTPUT (policy ACCEPT) target prot opt source destination

    Read the article

  • Windows installation repair option not showing up

    - by Carl
    I'm trying to repair an existing Windows XP installation. Following the instructions from http://www.microsoft.com/windowsxp/using/helpandsupport/learnmore/tips/doug92.mspx this should work: When the Press any key to boot from CD message is displayed on your screen, press a key to start your computer from the Windows XP CD. Press ENTER when you see the message To setup Windows XP now, and then press ENTER displayed on the Welcome to Setup screen. Do not choose the option to press R to use the Recovery Console. In the Windows XP Licensing Agreement, press F8 to agree to the license agreement. Make sure that your current installation of Windows XP is selected in the box, and then press R to repair Windows XP. Follow the instructions on the screen to complete Setup. On step 5 pressing R does nothing and there is nothing on the screen saying it would. When I just select to install I get a message that a previous installation is there and proceeding will destroy it and installed applications, I can optionally select a directory other than c:\windows, and I can optionally format before continuing. I had tried to go from SP2-SP3. It failed, and then I couldn't get to Safe Mode. I put the SP1 disk back in to do a repair, and I don't see that option. (I don't have an SP2 boot/install disk, I just have the non-boot upgrade package.) UPDATE: Upon loading the Recovery Console, I get a message saying The system registry does not appear to have an active ControlSet key. The system registry may be damaged. You can try restarting it with the Last Known Good configuration or you can try repairing the installation of Windows using the setup program's repair and recovery options. I then did bootcfg /scan - "successful" ... Total installs: 1 ... [1] c:\windows - with the c:\windows command prompt below it. bootcfg /list gives [1] Windows XP Pro; OS Load Options /noexecute=optin /fastdetect; OS Location: c:\windows I followed the instructions at http://michaelstevenstech.com/XPrepairinstall.htm - "Warning 2" link copy E:\i386\ntldr C:\ copy E:\i386\ntdetect.com C:\ attrib -h -r -s C:\boot.ini del C:\boot.ini BootCfg /Rebuild I added /fastdetect when it asked for options. I re-ran Windows setup - no change - no repair option. UPDATE: I followed the procedure at http://support.microsoft.com/default.aspx?scid=kb;en-us;307545 I rebooted. I now get a quick message on bootup to select the boot - 1: [blank] ; Windows XP Professional ; Windows Recover Console. The "1: " is new. The rest is the way it was when all was okay. Selecting 1: and the next one gives the same result - I get to a login icon, and then it asks for a password, with the blinking cursor, but I can't type anything. I reboot with the Windows CD. Now I see a repair option for installation "1: " I selected R on that, and it did "Setup is copying files..." and rebooted when it was done. Then it booted, and I got a window saying "Setup will complete in approximately 39 minutes." That's where I am now. I wasn't expecting this last part - I did a repair several months ago and I don't recall that. UPDATE: Booted up. Asked if I wanted to register Windows online. All my icons are there, and the old desktop documents. Good. All the applications I tried from the Start Menu work (tested a few), except Corel Photopaint - I get registry entry not found errors. Windows ran for a while, then froze. The mouse and keyboard don't work. Pressing the power button got Windows to shut down. I probably need to put SP2 on it, and then all the updates for my laptop for XP Pro SP2 (drivers), there's a bunch. The mouse and keyboard quit working again. That wasn't a problem when I first set up this laptop. I've ran 4 times now. Two mouse/keyboards hangs by pressing Ctrl-C (to copy text from a notepad document), and two by selecting Start-Run (wasn't able to type anything in the box).

    Read the article

  • My linux server takes more than an hour to boot. Suggestions?

    - by jamieb
    I am building a CentOS 5.4 system that boots off a compact flash card using a card reader that emulates an IDE drive. It literally takes about an hour to boot. The ultra-slow part occurs when Grub is loading the kernel. Once that's done, the rest of the boot process only takes about a minute to get to a login prompt. Does anyone have any suggestions? I suspect that it may have to do with UDMA. Everything IDE-related in my BIOS seems to checkout. The read performance hdparm is telling me 1.77 MB/s. Ouch! (But even at that rate, it still shouldn't take an hour to decompress and load the kernel) [root@server ~]# hdparm -tT /dev/hdc /dev/hdc: Timing cached reads: 2444 MB in 2.00 seconds = 1222.04 MB/sec Timing buffered disk reads: 6 MB in 3.39 seconds = 1.77 MB/sec Trying to enable DMA is a no-go though: [root@server ~]# hdparm -d1 /dev/hdc /dev/hdc: setting using_dma to 1 (on) HDIO_SET_DMA failed: Operation not permitted using_dma = 0 (off) Here's some command outputs that might help: System [root@server ~]# uname -a Linux server.localdomain 2.6.18-164.el5xen #1 SMP Thu Sep 3 04:47:32 EDT 2009 i686 i686 i386 GNU/Linux PCI info: [root@server ~]# lspci -v 00:00.0 Host bridge: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub (rev 02) Subsystem: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub Flags: bus master, fast devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:02.0 VGA compatible controller: Intel Corporation 82945G/GZ Integrated Graphics Controller (rev 02) (prog-if 00 [VGA controller]) Subsystem: Intel Corporation 82945G/GZ Integrated Graphics Controller Flags: bus master, fast devsel, latency 0, IRQ 10 Memory at fdf00000 (32-bit, non-prefetchable) [size=512K] I/O ports at ff00 [size=8] Memory at d0000000 (32-bit, prefetchable) [size=256M] Memory at fdf80000 (32-bit, non-prefetchable) [size=256K] Capabilities: [90] Message Signalled Interrupts: 64bit- Queue=0/0 Enable- Capabilities: [d0] Power Management version 2 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 Flags: bus master, medium devsel, latency 0, IRQ 16 I/O ports at fe00 [size=32] 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 Flags: bus master, medium devsel, latency 0, IRQ 17 I/O ports at fd00 [size=32] 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 Flags: bus master, medium devsel, latency 0, IRQ 18 I/O ports at fc00 [size=32] 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 Flags: bus master, medium devsel, latency 0, IRQ 19 I/O ports at fb00 [size=32] 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) (prog-if 20 [EHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller Flags: bus master, medium devsel, latency 0, IRQ 16 Memory at fdfff000 (32-bit, non-prefetchable) [size=1K] Capabilities: [50] Power Management version 2 Capabilities: [58] Debug port 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) (prog-if 01 [Subtractive decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=01, subordinate=01, sec-latency=32 I/O behind bridge: 0000d000-0000dfff Memory behind bridge: fde00000-fdefffff Prefetchable memory behind bridge: 00000000fdd00000-00000000fdd00000 Capabilities: [50] #0d [0000] 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) Subsystem: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge Flags: bus master, medium devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) (prog-if 80 [Master]) Subsystem: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller Flags: bus master, 66MHz, medium devsel, latency 0, IRQ 17 I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at f800 [size=16] Capabilities: [70] Power Management version 2 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) Subsystem: Intel Corporation 82801G (ICH7 Family) SMBus Controller Flags: medium devsel, IRQ 17 I/O ports at 0500 [size=32] 01:04.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 18 I/O ports at de00 [size=256] Memory at fdeff000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:06.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 17 I/O ports at dc00 [size=256] Memory at fdefe000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:07.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 19 I/O ports at da00 [size=256] Memory at fdefd000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 hdparm ouput: [root@server ~]# hdparm /dev/hdc /dev/hdc: multcount = 0 (off) IO_support = 0 (default 16-bit) unmaskirq = 0 (off) using_dma = 0 (off) keepsettings = 0 (off) readonly = 0 (off) readahead = 256 (on) geometry = 8146/16/63, sectors = 8211168, start = 0 [root@server ~]# hdparm -I /dev/hdc /dev/hdc: ATA device, with non-removable media Model Number: InnoDisk Corp. - iCF4000 4GB Serial Number: 20091023AACA70000753 Firmware Revision: 081107 Standards: Supported: 5 Likely used: 6 Configuration: Logical max current cylinders 8146 8146 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 8211168 LBA user addressable sectors: 8211168 device size with M = 1024*1024: 4009 MBytes device size with M = 1000*1000: 4204 MBytes (4 GB) Capabilities: LBA, IORDY(can be disabled) Standby timer values: spec'd by Vendor R/W multiple sector transfer: Max = 2 Current = 2 DMA: mdma0 mdma1 mdma2 udma0 udma1 *udma2 udma3 udma4 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * Power Management feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * CFA feature set * Mandatory FLUSH_CACHE HW reset results: CBLID- above Vih Device num = 0 CFA power mode 1: enabled and required by some commands Maximum current = 100ma Checksum: correct

    Read the article

  • vsftpd not allowing uploads. 550 response.

    - by Josh
    I've set vsftpd up on a centos box. I keep trying to upload files but I keep getting "550 Failed to change directory" and "550 Could not get file size." Here's my vsftpd.conf # The default compiled in settings are fairly paranoid. This sample file # loosens things up a bit, to make the ftp daemon more usable. # Please see vsftpd.conf.5 for all compiled in defaults. # # READ THIS: This example file is NOT an exhaustive list of vsftpd options. # Please read the vsftpd.conf.5 manual page to get a full idea of vsftpd's # capabilities. # # Allow anonymous FTP? (Beware - allowed by default if you comment this out). anonymous_enable=YES # # Uncomment this to allow local users to log in. local_enable=YES # # Uncomment this to enable any form of FTP write command. write_enable=YES # # Default umask for local users is 077. You may wish to change this to 022, # if your users expect that (022 is used by most other ftpd's) local_umask=022 # # Uncomment this to allow the anonymous FTP user to upload files. This only # has an effect if the above global write enable is activated. Also, you will # obviously need to create a directory writable by the FTP user. anon_upload_enable=YES # # Uncomment this if you want the anonymous FTP user to be able to create # new directories. anon_mkdir_write_enable=YES anon_other_write_enable=YES # # Activate directory messages - messages given to remote users when they # go into a certain directory. dirmessage_enable=YES # # The target log file can be vsftpd_log_file or xferlog_file. # This depends on setting xferlog_std_format parameter xferlog_enable=YES # # Make sure PORT transfer connections originate from port 20 (ftp-data). connect_from_port_20=YES # # If you want, you can arrange for uploaded anonymous files to be owned by # a different user. Note! Using "root" for uploaded files is not # recommended! #chown_uploads=YES #chown_username=whoever # # The name of log file when xferlog_enable=YES and xferlog_std_format=YES # WARNING - changing this filename affects /etc/logrotate.d/vsftpd.log #xferlog_file=/var/log/xferlog # # Switches between logging into vsftpd_log_file and xferlog_file files. # NO writes to vsftpd_log_file, YES to xferlog_file xferlog_std_format=NO # # You may change the default value for timing out an idle session. #idle_session_timeout=600 # # You may change the default value for timing out a data connection. #data_connection_timeout=120 # # It is recommended that you define on your system a unique user which the # ftp server can use as a totally isolated and unprivileged user. #nopriv_user=ftpsecure # # Enable this and the server will recognise asynchronous ABOR requests. Not # recommended for security (the code is non-trivial). Not enabling it, # however, may confuse older FTP clients. #async_abor_enable=YES # # By default the server will pretend to allow ASCII mode but in fact ignore # the request. Turn on the below options to have the server actually do ASCII # mangling on files when in ASCII mode. # Beware that on some FTP servers, ASCII support allows a denial of service # attack (DoS) via the command "SIZE /big/file" in ASCII mode. vsftpd # predicted this attack and has always been safe, reporting the size of the # raw file. # ASCII mangling is a horrible feature of the protocol. #ascii_upload_enable=YES #ascii_download_enable=YES # # You may fully customise the login banner string: #ftpd_banner=Welcome to blah FTP service. # # You may specify a file of disallowed anonymous e-mail addresses. Apparently # useful for combatting certain DoS attacks. #deny_email_enable=YES # (default follows) #banned_email_file=/etc/vsftpd/banned_emails # # You may specify an explicit list of local users to chroot() to their home # directory. If chroot_local_user is YES, then this list becomes a list of # users to NOT chroot(). #chroot_list_enable=YES # (default follows) #chroot_list_file=/etc/vsftpd/chroot_list # # You may activate the "-R" option to the builtin ls. This is disabled by # default to avoid remote users being able to cause excessive I/O on large # sites. However, some broken FTP clients such as "ncftp" and "mirror" assume # the presence of the "-R" option, so there is a strong case for enabling it. #ls_recurse_enable=YES # # When "listen" directive is enabled, vsftpd runs in standalone mode and # listens on IPv4 sockets. This directive cannot be used in conjunction # with the listen_ipv6 directive. listen=YES # This directive enables listening on IPv6 sockets. To listen on IPv4 and IPv6 # sockets, you must run two copies of vsftpd whith two configuration files. # Make sure, that one of the listen options is commented !! #listen_ipv6=YES pam_service_name=vsftpd userlist_enable=YES tcp_wrappers=YES log_ftp_protocol=YES banner_file=/etc/vsftpd/issue local_root=/var/www guest_enable=YES guest_username=ftpusr ftp_username=nobody

    Read the article

  • Mount TMPFS instead of ro /dev

    - by schiggn
    I am working on a ARM-Based embedded system with a custom Debian Linux based on kernel 2.6.31. In the final system, the Root file system is stored as squashfs on flash. Now, the folder /dev is created by udev, but since there is no hot plugging functionality needed and booting time is critical, I wanted to delete udev and "hard code" the /dev folder (read here, page 5). because i still need to change parameters of the devices (with ioctl /sysfs) this does not work for me in this case. so i thought of mounting a tmpfs on /dev and change the parameters there. is this possible? and how to do best? my approach would be: delete /dev from RFS create tar containing basic devices mount tmpfs /dev untar tar-file into /dev change parameters Could this work? Do you see any problems? I found out, that you can mount on top of already mounted mount point, is it somehow possible just to take data with while mounting the new file system? if so that would be very convenient! Thanks Update: I just tried that out, but I'm stuck at a certain point. I packed all my devices into devices.tar, packed it into /usr of my squashfs and added the following lines to mountkernfs.sh, which is executed right after INIT. #mount /dev on tmpfs echo -n "Mounting /dev on tmpfs..." mount -o size=5M,mode=0755 -t tmpfs tmpfs /dev mknod -m 600 /dev/console c 5 1 mknod -m 600 /dev/null c 1 3 echo "done." echo -n "Populating /dev..." tar -xf /usr/devices.tar -C /dev echo "done." This works fine on the version over NFS, if I place printf's in the code, I can see it executing, if I comment out the extracting part, its complaining about missing devices. Booting OK mmc0: new high speed SDHC card at address 0007 mmcblk0: mmc0:0007 SD04G 3.67 GiB mmcblk0: p1 IP-Config: Unable to set interface netmask (-22). Looking up port of RPC 100003/2 on 192.168.1.234 Looking up port of RPC 100005/1 on 192.168.1.234 VFS: Mounted root (nfs filesystem) on device 0:14. Freeing init memory: 136K INIT: version 2.86 booting Mounting /dev on tmpfs...done. Populating /dev...done. Initializing /var...done. Setting the system clock. System Clock set to: Thu Sep 13 11:26:23 UTC 2012. INIT: Entering runlevel: 2 UBI: attaching mtd8 to ubi0 Commenting out the extraction of the tar mmc0: new high speed SDHC card at address 0007 mmcblk0: mmc0:0007 SD04G 3.67 GiB mmcblk0: p1 IP-Config: Unable to set interface netmask (-22). Looking up port of RPC 100003/2 on 192.168.1.234 Looking up port of RPC 100005/1 on 192.168.1.234 VFS: Mounted root (nfs filesystem) on device 0:14. Freeing init memory: 136K INIT: version 2.86 booting Mounting /dev on tmpfs...done. Populating /dev...done. Initializing /var...done. Setting the system clock. Cannot access the Hardware Clock via any known method. Use the --debug option to see the details of our search for an access method. Unable to set System Clock to: Thu Sep 13 12:24:00 UTC 2012 ... (warning). INIT: Entering runlevel: 2 libubi: error!: cannot open "/dev/ubi_ctrl" So far so good. But if I pack the whole story into a squashfs and boot from there, it is acting strange. It's telling me while booting that it is unable to open an initial console and its throwing errors on mounting the UBIFS devices, but finally provides a login anyway. Over that my echo's are not executed. If I then log in, /dev is mounted as TMPFS as desired and all the devices reside inside. When I redo the "mount" command to mount the UBIFS partitions it is executed whitout problem and useable. From squashfs VFS: Mounted root (squashfs filesystem) readonly on device 31:15. Freeing init memory: 136K Warning: unable to open an initial console. mmc0: new high speed SDHC card at address 0007 mmcblk0: mmc0:0007 SD04G 3.67 GiB mmcblk0: p1 UBIFS error (pid 484): ubifs_get_sb: cannot open "ubi1_0", error -19 Additionally, a part of the rest of the bootscripts is still exexuted, but not all of them. Does anyone has a clue why? Other question, is 5MB enough/too much for /dev?

    Read the article

  • Why are my USB 2.0 devices hanging Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a DFI CM33-TL/G ATX (identified using SiSoft Sandra) motherboard hosting an Intel Celeron 1.3GHz CPU, 768Mb PC133 SDRAM, a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board based on the NEC uPD720102 chipset containing 3 external and 1 internal USB sockets. It's also hosting a 1.44Mb floppy drive on FDD0, a new 80Gb Western Digital hard drive running as master on IDE0 and a Panasonic DVD+/-RW running as master on IDE1. All this is sitting in a slimline case running off a Macron Power MPT-135 135W Flex power supply. The motherboard is running a version of Award BIOS 05/24/2002-601T-686B-6A6LID4AC-00. Could this be updated? If so, from where? I've raked through the manufacturer's website but can't find any hint of downloads for either drivers or BIOS updates. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine?

    Read the article

  • Bypass cache for mobile user agents, VARNISH+NGINX+W3CACHE

    - by Mike McGhee
    Right now I'm running Wordpress w/ W3 Cache on nginx with varnish front end. I'm trying to use the WP Touch Pro plugin for wordpress to display mobile sites, but it is not working. Shows the desktop theme still. I've put the mobile user agents in the rejected user agents box in w3 cache. Here is the nginx config w3 cache spit out: BEGIN W3TC Page Cache cache location ~ /wp-content/w3tc/pgcache.*html$ { expires modified 3600s; add_header X-Powered-By "W3 Total Cache/0.9.2.4"; add_header Vary "Accept-Encoding, Cookie"; } location ~ /wp-content/w3tc/pgcache.*gzip$ { gzip off; types {} default_type text/html; expires modified 3600s; add_header X-Powered-By "W3 Total Cache/0.9.2.4"; add_header Vary "Accept-Encoding, Cookie"; add_header Content-Encoding gzip; } # END W3TC Page Cache cache # BEGIN W3TC Browser Cache gzip on; gzip_types text/css application/x-javascript text/x-component text/richtext image/svg+xml text/plain text/xsd text/xsl text/xml image/x-icon; location ~ \.(css|js|htc)$ { expires 31536000s; add_header X-Powered-By "W3 Total Cache/0.9.2.4"; } location ~ \.(html|htm|rtf|rtx|svg|svgz|txt|xsd|xsl|xml)$ { expires 3600s; add_header X-Powered-By "W3 Total Cache/0.9.2.4"; } location ~ \.(asf|asx|wax|wmv|wmx|avi|bmp|class|divx|doc|docx|eot|exe|gif|gz|gzip|ico|jpg|jpeg|jpe|mdb|mid|midi|mov|qt|mp3|m4a|mp4|m4v|mpeg|mpg|mpe|mpp|otf|odb|odc|odf|odg|odp|ods|odt|ogg|pdf|png|pot|pps|ppt|pptx|ra|ram|svg|svgz|swf|tar|tif|tiff|ttf|ttc|wav|wma|wri|xla|xls|xlsx|xlt|xlw|zip)$ { expires 31536000s; add_header X-Powered-By "W3 Total Cache/0.9.2.4"; } # END W3TC Browser Cache # BEGIN W3TC Minify core rewrite ^/wp-content/w3tc/min/w3tc_rewrite_test$ /wp-content/w3tc/min/index.php?w3tc_rewrite_test=1 last; rewrite ^/wp-content/w3tc/min/(.+\.(css|js))$ /wp-content/w3tc/min/index.php?file=$1 last; # END W3TC Minify core # BEGIN W3TC Page Cache core rewrite ^(.*\/)?w3tc_rewrite_test$ $1?w3tc_rewrite_test=1 last; set $w3tc_rewrite 1; if ($request_method = POST) { set $w3tc_rewrite 0; } if ($query_string != "") { set $w3tc_rewrite 0; } if ($http_host != "mysite.com") { set $w3tc_rewrite 0; } set $w3tc_rewrite2 1; if ($request_uri !~ \/$) { set $w3tc_rewrite2 0; } if ($request_uri ~* "(sitemap(_index)?\.xml(\.gz)?|[a-z0-9_\-]+-sitemap([0-9]+)?\.xml(\.gz)?)") { set $w3tc_rewrite2 1; } if ($w3tc_rewrite2 != 1) { set $w3tc_rewrite 0; } set $w3tc_rewrite3 1; if ($request_uri ~* "(\/wp-admin\/|\/xmlrpc.php|\/wp-(app|cron|login|register|mail)\.php|\/feed\/|wp-.*\.php|index\.php)") { set $w3tc_rewrite3 0; } if ($request_uri ~* "(wp\-comments\-popup\.php|wp\-links\-opml\.php|wp\-locations\.php)") { set $w3tc_rewrite3 1; } if ($w3tc_rewrite3 != 1) { set $w3tc_rewrite 0; } if ($http_cookie ~* "(comment_author|wp\-postpass|wordpress_\[a\-f0\-9\]\+|wordpress_logged_in)") { set $w3tc_rewrite 0; } if ($http_user_agent ~* "(W3\ Total\ Cache/0\.9\.2\.4|iphone|ipod|ipad|aspen|incognito|webmate|android|dream|cupcake|froyo|blackberry9500|blackberry9520|blackberry9530|blackberry9550|blackberry\ 9800|blackberry\ 9780|webos|s8000|bada)") { set $w3tc_rewrite 0; } set $w3tc_ua ""; if ($http_user_agent ~* "(acer\ s100|android|archos5|blackberry9500|blackberry9530|blackberry9550|blackberry\ 9800|cupcake|docomo\ ht\-03a|dream|htc\ hero|htc\ magic|htc_dream|htc_magic|incognito|ipad|iphone|ipod|kindle|lg\-gw620|liquid\ build|maemo|mot\-mb200|mot\-mb300|nexus\ one|opera\ mini|samsung\-s8000|series60.*webkit|series60/5\.0|sonyericssone10|sonyericssonu20|sonyericssonx10|t\-mobile\ mytouch\ 3g|t\-mobile\ opal|tattoo|webmate|webos)") { set $w3tc_ua _high; } set $w3tc_ref ""; set $w3tc_ssl ""; set $w3tc_enc ""; if ($http_accept_encoding ~ gzip) { set $w3tc_enc _gzip; } set $w3tc_ext ""; if (-f "$document_root/wp-content/w3tc/pgcache/$request_uri/_index$w3tc_ua$w3tc_ref$w3tc_ssl.html$w3tc_enc") { set $w3tc_ext .html; } if ($w3tc_ext = "") { set $w3tc_rewrite 0; } if ($w3tc_rewrite = 1) { rewrite .* "/wp- content/w3tc/pgcache/$request_uri/_index$w3tc_ua$w3tc_ref$w3tc_ssl$w3tc_ext$w3tc_enc" last; } # END W3TC Page Cache core And here is what I have in my varnish vcl.. sub vcl_recv { # Add a unique header containing the client address remove req.http.X-Forwarded-For; set req.http.X-Forwarded-For = client.ip; # Device detection set req.http.X-Device = "desktop"; if ( req.http.User-Agent ~ "iP(hone|od|ad)" || req.http.User-Agent ~ "Android" ) { set req.http.X-Device = "smart"; } elseif ( req.http.User-Agent ~ "(SymbianOS|BlackBerry|SonyEricsson|Nokia|SAMSUNG|^LG)" ) { set req.http.X-Device = "cell"; } Any help is greatly appreciated, I've been banging my head against this for 2 days..

    Read the article

  • Portable scripting language for a multi-server admin?

    - by Aaron
    Please Note: Portable as in portableapps.com, not the traditional definition. Originally posted on stackoverflow.com, asking here at another user's suggestion. I'm a DBA and sysadmin, mostly for Windows machines running SQL Server. I'm looking for a programming/scripting language for Windows that doesn't require Admin access or an installer, needing no install process other than expanding it into a folder. My intent is to have a language for automation on which I can standardize. Up to this point, I've been using a combination of batch files and Unix shell, using sh.exe from UnxUtils but it's far from a perfect solution. I've evaluated a handful of options, all of them have at least one serious shortcoming or another. I have a strong preference for something open source or dual license, but I'm more interested in finding the right tool than anything else. Not interested that anything that relies on Cygwin or Java, but at this point I'd be fine with something that needs .NET. Requirements: Manageable footprint (1-100 files, under 30 MB installed) Run on Windows XP and Server (2003+) No installer (exe, msi) Works with external pipes, processes, and files Support for MS SQL Server or ODBC connections Bonus Points: Open Source FFI for calling functions in native DLLs GUI support (native or gtk, wx, fltk, etc) Linux, AIX, and/or OS X support Dynamic, object oriented and/or functional, interpreted or bytecode compiled; interactive development Able to package or compile scripts into executables So far I've tried: Ruby: 148 MB on disk, 23000 files Portable Python: 54 MB on disk, 2800 files Strawberry Perl: 123 MB on disk, 3600 files REBOL: Great, except closed source and no MSSQL or ODBC in free version Squeak Smalltalk: Great, except poor support for scripting ---- cut: points of clarification ---- Why all the limitations? I realize some of my criteria seem arbitrarily confining. It's primarily a product my environment. I work as a SQL Server DBA and backup Unix admin at a division of a large company. In addition to near a hundred boxes running some version or another of SQL Server on Windows, I also support the SQL Server Express Edition installs on over a thousand machines in the field. Because of our security policies, I don't login rights on every machine. Often enough, an issue comes up and I'm given local Admin for some period of time. Often enough, it's some box I've never touched and don't have my own environment setup yet. I may have temporary admin rights on the box, but I'm not the admin for the machine- I'm just the DBA. I've no interest in stepping on the toes of the Windows admins, nor do I want to take over any of their duties. If I bring up "installing" something, suddenly it becomes a matter of interest for Production Control and the Windows admins; if I'm copying up a script, no one minds. The distinction may not mean much to the readers, but if someone gets the wrong idea I've suddenly got a long wait and significant overhead before I can get the tool installed and get the problem solved. That's why I want something that can be copied and run in the manner of a portable app. What about the small footprint? My company has three divisions, each in a different geographical location, and one of them is a new acquisition. We have different production control/security policies in each division. I support our MSSQL databases in all three divisions. The field machines are spread around the US, sometimes connecting to the VPN over very slow links. Installing Ruby \using psexec has taken a long time over these connections. In these instances, the bigger time waster seems to be archives with thousands and thousands of files rather than their sheer size. You could say I'm spoiled by Unix, where the admins usually have at least some modern scripting language installed; I'd use PowerShell, but I don't know it well and more importantly it isn't everywhere I need to work. It's a regular occurrence that I need to write, deploy and execute some script on short notice on some machine I've never on which logged in. Since having Ruby or something similar installed on every machine I'll ever need to touch is effectively impossible because of the approvals, time and and Windows admin labor needed I makes more sense find a solution that allows me to work on my own terms.

    Read the article

  • How to set up linux watchdog daemon with Intel 6300esb

    - by ACiD GRiM
    I've been searching for this on Google for sometime now and I have yet to find proper documentation on how to connect the kernel driver for my 6300esb watchdog timer to /dev/watchdog and ensure that watchdog daemon is keeping it alive. I am using RHEL compatible Scientific Linux 6.3 in a KVM virtual machine by the way Below is everything I've tried so far: dmesg|grep 6300 i6300ESB timer: Intel 6300ESB WatchDog Timer Driver v0.04 i6300ESB timer: initialized (0xffffc900008b8000). heartbeat=30 sec (nowayout=0) | ll /dev/watchdog crw-rw----. 1 root root 10, 130 Sep 22 22:25 /dev/watchdog | /etc/watchdog.conf #ping = 172.31.14.1 #ping = 172.26.1.255 #interface = eth0 file = /var/log/messages #change = 1407 # Uncomment to enable test. Setting one of these values to '0' disables it. # These values will hopefully never reboot your machine during normal use # (if your machine is really hung, the loadavg will go much higher than 25) max-load-1 = 24 max-load-5 = 18 max-load-15 = 12 # Note that this is the number of pages! # To get the real size, check how large the pagesize is on your machine. #min-memory = 1 #repair-binary = /usr/sbin/repair #test-binary = #test-timeout = watchdog-device = /dev/watchdog # Defaults compiled into the binary #temperature-device = #max-temperature = 120 # Defaults compiled into the binary #admin = root interval = 10 #logtick = 1 # This greatly decreases the chance that watchdog won't be scheduled before # your machine is really loaded realtime = yes priority = 1 # Check if syslogd is still running by enabling the following line #pidfile = /var/run/syslogd.pid Now maybe I'm not testing it correctly, but I would expecting that stopping the watchdog service would cause the /dev/watchdog to time out after 30 seconds and I should see the host reboot, however this does not happen. Also, here is my config for the KVM vm <!-- WARNING: THIS IS AN AUTO-GENERATED FILE. CHANGES TO IT ARE LIKELY TO BE OVERWRITTEN AND LOST. Changes to this xml configuration should be made using: virsh edit sl6template or other application using the libvirt API. --> <domain type='kvm'> <name>sl6template</name> <uuid>960d0ac2-2e6a-5efa-87a3-6bb779e15b6a</uuid> <memory unit='KiB'>262144</memory> <currentMemory unit='KiB'>262144</currentMemory> <vcpu placement='static'>1</vcpu> <os> <type arch='x86_64' machine='rhel6.3.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <cpu mode='custom' match='exact'> <model fallback='allow'>Westmere</model> <vendor>Intel</vendor> <feature policy='require' name='tm2'/> <feature policy='require' name='est'/> <feature policy='require' name='vmx'/> <feature policy='require' name='ds'/> <feature policy='require' name='smx'/> <feature policy='require' name='ss'/> <feature policy='require' name='vme'/> <feature policy='require' name='dtes64'/> <feature policy='require' name='rdtscp'/> <feature policy='require' name='ht'/> <feature policy='require' name='dca'/> <feature policy='require' name='pbe'/> <feature policy='require' name='tm'/> <feature policy='require' name='pdcm'/> <feature policy='require' name='pdpe1gb'/> <feature policy='require' name='ds_cpl'/> <feature policy='require' name='pclmuldq'/> <feature policy='require' name='xtpr'/> <feature policy='require' name='acpi'/> <feature policy='require' name='monitor'/> <feature policy='require' name='aes'/> </cpu> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/mnt/data/vms/sl6template.img'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </disk> <controller type='usb' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x2'/> </controller> <interface type='bridge'> <mac address='52:54:00:44:57:f6'/> <source bridge='br0.2'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:88:0f:42'/> <source bridge='br1'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target type='serial' port='0'/> </console> <watchdog model='i6300esb' action='reset'> <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/> </watchdog> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </memballoon> </devices> </domain> Any help is appreciated as the most I've found are patches to kvm and general softdog documentation or IPMI watchdog answers.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • sshd running but no PID file

    - by dunxd
    I'm recently started using monit to monitor the status of sshd on my CentOS 5.4 server. This works fine, but every so often monit reports that sshd is no longer running. This isn't true - I am still able to login to the server via ssh, however I note the following: There is no longer any PID file at /var/run/sshd.pid - after a reboot this file exists. Once it is gone, restarting sshd via service sshd restart does not create the PID file. sudo service sshd status reports openssh-daemon is stopped - again, restarting sshd does not change this, but a reboot does. sudo service sshd stop reports failed, presumably because of the missing PID file. Any idea what is going on? Update sudo netstat -lptun gives the following output relating to port 22 tcp 0 0 :::22 :::* LISTEN 20735/sshd Killing the process with this PID as suggested by @Henry and then starting sshd via service results in service sshd status recognising the process by PID again. Would still like to understand this better. RPM verify suggested by a couple of answerers shows this: sudo rpm -vV openssh openssh-server openssh-clients | grep 'S\.5' S.5....T c /etc/pam.d/sshd S.5....T c /etc/ssh/sshd_config /etc/pam.d/sshd has the following contents: #%PAM-1.0 auth include system-auth account required pam_nologin.so account include system-auth password include system-auth session optional pam_keyinit.so force revoke session include system-auth #session required pam_loginuid.so Should that last line be commented out? Update Here's the output of @YannickGirouard 's script: $ sudo ./sshd_test Searching for the process listening on port 22... Found the following PID: 21330 Command line for PID 21330: /usr/sbin/sshd Listing process(es) relating to PID 21330: UID PID PPID C STIME TTY TIME CMD root 21330 1 0 14:04 ? 00:00:00 /usr/sbin/sshd Listing RPM information about openssh packages: Name : openssh Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:50:57 AM GMT Build Host: builder10.centos.org Group : Applications/Internet Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 745390 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH implementation of SSH protocol versions 1 and 2 ------------------------------------------------------ Name : openssh-clients Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:51:04 AM GMT Build Host: builder10.centos.org Group : Applications/Internet Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 871132 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH client applications ------------------------------------------------------ Name : openssh-server Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:51:04 AM GMT Build Host: builder10.centos.org Group : System Environment/Daemons Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 492478 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH server daemon ------------------------------------------------------ However, I've since got things working by killing the process and starting afresh, as suggested by @Henry below, so perhaps I am no longer seeing the same thing. Will try again if I am seeing the issue again after next reboot. Update - 14 March Monit alerted me that sshd had disappeared, and again I am able to ssh onto the server. So now I can run the script $ sudo ./sshd_test Searching for the process listening on port 22... Found the following PID: 2208 Command line for PID 2208: /usr/sbin/sshd Listing process(es) relating to PID 2208: UID PID PPID C STIME TTY TIME CMD root 2208 1 0 Mar13 ? 00:00:00 /usr/sbin/sshd root 1885 2208 0 21:50 ? 00:00:00 sshd: dunx [priv] Listing RPM information about openssh packages: Name : openssh Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:50:57 AM GMT Build Host: builder10.centos.org Group : Applications/Internet Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 745390 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH implementation of SSH protocol versions 1 and 2 ------------------------------------------------------ Name : openssh-clients Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:51:04 AM GMT Build Host: builder10.centos.org Group : Applications/Internet Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 871132 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH client applications ------------------------------------------------------ Name : openssh-server Relocations: (not relocatable) Version : 4.3p2 Vendor: CentOS Release : 72.el5_7.5 Build Date: Tue 30 Aug 2011 12:34:14 AM BST Install Date: Sun 06 Nov 2011 12:51:04 AM GMT Build Host: builder10.centos.org Group : System Environment/Daemons Source RPM: openssh-4.3p2-72.el5_7.5.src.rpm Size : 492478 License: BSD Signature : DSA/SHA1, Fri 02 Sep 2011 01:13:01 AM BST, Key ID a8a447dce8562897 URL : http://www.openssh.com/portable.html Summary : The OpenSSH server daemon ------------------------------------------------------ Again, when I look for /var/run/sshd.pid I don't find it. $ cat /var/run/sshd.pid cat: /var/run/sshd.pid: No such file or directory $ sudo netstat -anp | grep sshd tcp 0 0 0.0.0.0:22 0.0.0.0:* LISTEN 2208/sshd $ sudo kill 2208 $ sudo service sshd start Starting sshd: [ OK ] $ cat /var/run/sshd.pid 3794 $ sudo service sshd status openssh-daemon (pid 3794) is running... Is it possible that sshd is restarting and not creating a pidfile for some reason?

    Read the article

  • Set up linux box for hosting a-z

    - by microchasm
    I am in the process of reinstalling the OS on a machine that will be used to host a couple of apps for our business. The apps will be local only; access from external clients will be via vpn only. The prior setup used a hosting control panel (Plesk) for most of the admin, and I was looking at using another similar piece of software for the reinstall - but I figured I should finally learn how it all works. I can do most of the things the software would do for me, but am unclear on the symbiosis of it all. This is all an attempt to further distance myself from the land of Configuration Programmer/Programmer, if at all possible. I can't find a full walkthrough anywhere for what I'm looking for, so I thought I'd put up this question, and if people can help me on the way I will edit this with the answers, and document my progress/pitfalls. Hopefully someday this will help someone down the line. The details: CentOS 5.5 x86_64 httpd: Apache/2.2.3 mysql: 5.0.77 (to be upgraded) php: 5.1 (to be upgraded) The requirements: SECURITY!! Secure file transfer Secure client access (SSL Certs and CA) Secure data storage Virtualhosts/multiple subdomains Local email would be nice, but not critical The Steps: Download latest CentOS DVD-iso (torrent worked great for me). Install CentOS: While going through the install, I checked the Server Components option thinking I was going to be using another Plesk-like admin. In hindsight, considering I've decided to try to go my own way, this probably wasn't the best idea. Basic config: Setup users, networking/ip address etc. Yum update/upgrade. Upgrade PHP/MySQL: To upgrade PHP and MySQL to the latest versions, I had to look to another repo outside CentOS. IUS looks great and I'm happy I found it! Add IUS repository to our package manager cd /tmp wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/epel-release-1-1.ius.el5.noarch.rpm rpm -Uvh epel-release-1-1.ius.el5.noarch.rpm wget http://dl.iuscommunity.org/pub/ius/stable/Redhat/5/x86_64/ius-release-1-4.ius.el5.noarch.rpm rpm -Uvh ius-release-1-4.ius.el5.noarch.rpm yum list | grep -w \.ius\. # list all the packages in the IUS repository; use this to find PHP/MySQL version and libraries you want to install Remove old version of PHP and install newer version from IUS rpm -qa | grep php # to list all of the installed php packages we want to remove yum shell # open an interactive yum shell remove php-common php-mysql php-cli #remove installed PHP components install php53 php53-mysql php53-cli php53-common #add packages you want transaction solve #important!! checks for dependencies transaction run #important!! does the actual installation of packages. [control+d] #exit yum shell php -v PHP 5.3.2 (cli) (built: Apr 6 2010 18:13:45) Upgrade MySQL from IUS repository /etc/init.d/mysqld stop rpm -qa | grep mysql # to see installed mysql packages yum shell remove mysql mysql-server #remove installed MySQL components install mysql51 mysql51-server mysql51-devel transaction solve #important!! checks for dependencies transaction run #important!! does the actual installation of packages. [control+d] #exit yum shell service mysqld start mysql -v Server version: 5.1.42-ius Distributed by The IUS Community Project Upgrade instructions courtesy of IUS wiki: http://wiki.iuscommunity.org/Doc/ClientUsageGuide Install rssh (restricted shell) to provide scp and sftp access, without allowing ssh login cd /tmp wget http://dag.wieers.com/rpm/packages/rssh/rssh-2.3.2-1.2.el5.rf.x86_64.rpm rpm -ivh rssh-2.3.2-1.2.el5.rf.x86_64.rpm useradd -m -d /home/dev -s /usr/bin/rssh dev passwd dev Edit /etc/rssh.conf to grant access to SFTP to rssh users. vi /etc/rssh.conf Uncomment or add: allowscp allowsftp This allows me to connect to the machine via SFTP protocol in Transmit (my FTP program of choice; I'm sure it's similar with other FTP apps). rssh instructions appropriated (with appreciation!) from http://www.cyberciti.biz/tips/linux-unix-restrict-shell-access-with-rssh.html Set up virtual interfaces ifconfig eth1:1 192.168.1.3 up #start up the virtual interface cd /etc/sysconfig/network-scripts/ cp ifcfg-eth1 ifcfg-eth1:1 #copy default script and match name to our virtual interface vi ifcfg-eth1:1 #modify eth1:1 script #ifcfg-eth1:1 | modify so it looks like this: DEVICE=eth1:1 IPADDR=192.168.1.3 NETMASK=255.255.255.0 NETWORK=192.168.1.0 ONBOOT=yes NAME=eth1:1 Add more Virtual interfaces as needed by repeating. Because of the ONBOOT=yes line in the ifcfg-eth1:1 file, this interface will be brought up when the system boots, or the network starts/restarts. service network restart Shutting down interface eth0: [ OK ] Shutting down interface eth1: [ OK ] Shutting down loopback interface: [ OK ] Bringing up loopback interface: [ OK ] Bringing up interface eth0: [ OK ] Bringing up interface eth1: [ OK ] ping 192.168.1.3 64 bytes from 192.168.1.3: icmp_seq=1 ttl=64 time=0.105 ms And this is where I'm at. I will keep editing this as I make progress. Any tips on how to Configure virtual interfaces/ip based virtual hosts for SSL, setting up a CA, or anything else would be appreciated.

    Read the article

  • Suspended Laptop Cannot Wake Up - Ubuntu

    - by Zack
    I've got an ASUS G73JH, and whenever I suspend it or hibernate it, it will not wake up. The screen stays backlight but is black. The fan remains running, however the HDD does not, not disk activity is noticeable (audibly (It's not a SSD)). I can't: Awaken it with the keyboard Awaken it with the mouse Soft power-off by pressing the power button Change virtual screens by pressing Ctrl-Alt-# Restart X by pressing Ctrl-Alt-Backspace I have to hold down the power button and shut it down that way, and this seems a little unreasonable. Is there a place I could look for more detail as to what's causing this? Is there a known quick-fix to this issue? Nothing is logged as happening when the system is in "suspend" mode. Here's what happened immediately before and after the suspend "happened," note the time gap: May 4 17:46:13 tofu NetworkManager: <info> (eth0): carrier now OFF (device state 1) May 4 17:48:57 tofu kernel: imklog 4.2.0, log source = /proc/kmsg started. This one's kinda long, here's what happened immediately before the suspend, I'm not sure if it'll help but if you can find a use for it: May 4 17:46:10 tofu anacron[3353]: Anacron 2.3 started on 2010-05-04 May 4 17:46:10 tofu anacron[3353]: Normal exit (0 jobs run) May 4 17:46:10 tofu kernel: [ 2241.775927] CPU0 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.775958] CPU1 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.775987] CPU2 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.776138] CPU3 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.776168] CPU4 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.776197] CPU5 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.776200] CPU6 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.776229] CPU7 attaching NULL sched-domain. May 4 17:46:10 tofu kernel: [ 2241.919611] CPU0 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.919668] domain 0: span 0,4 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.919699] groups: 0 (cpu_power = 589) 4 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.919733] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.919762] groups: 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.919850] CPU1 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.919852] domain 0: span 1,5 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.919881] groups: 1 (cpu_power = 589) 5 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.919912] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.919915] groups: 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920003] CPU2 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920005] domain 0: span 2,6 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920033] groups: 2 (cpu_power = 589) 6 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920065] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920093] groups: 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920155] CPU3 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920157] domain 0: span 3,7 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920185] groups: 3 (cpu_power = 589) 7 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920217] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920245] groups: 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920307] CPU4 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920335] domain 0: span 0,4 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920337] groups: 4 (cpu_power = 589) 0 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920368] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920397] groups: 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920459] CPU5 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920487] domain 0: span 1,5 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920489] groups: 5 (cpu_power = 589) 1 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920520] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920549] groups: 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920611] CPU6 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920639] domain 0: span 2,6 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920641] groups: 6 (cpu_power = 589) 2 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920699] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920701] groups: 2,6 (cpu_power = 1178) 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) May 4 17:46:10 tofu kernel: [ 2241.920762] CPU7 attaching sched-domain: May 4 17:46:10 tofu kernel: [ 2241.920791] domain 0: span 3,7 level SIBLING May 4 17:46:10 tofu kernel: [ 2241.920793] groups: 7 (cpu_power = 589) 3 (cpu_power = 589) May 4 17:46:10 tofu kernel: [ 2241.920851] domain 1: span 0-7 level MC May 4 17:46:10 tofu kernel: [ 2241.920853] groups: 3,7 (cpu_power = 1178) 0,4 (cpu_power = 1178) 1,5 (cpu_power = 1178) 2,6 (cpu_power = 1178) May 4 17:46:12 tofu NetworkManager: <info> Sleeping... May 4 17:46:12 tofu NetworkManager: <info> (wlan0): now unmanaged May 4 17:46:12 tofu NetworkManager: <info> (wlan0): device state change: 8 -> 1 (reason 37) May 4 17:46:12 tofu NetworkManager: <info> (wlan0): deactivating device (reason: 37). May 4 17:46:12 tofu NetworkManager: <info> (wlan0): canceled DHCP transaction, dhcp client pid 1984 May 4 17:46:12 tofu kernel: [ 2244.084515] wlan0: deauthenticating from 68:7f:74:23:02:ae by local choice (reason=3) May 4 17:46:12 tofu avahi-daemon[1176]: Withdrawing address record for 192.168.1.2 on wlan0. May 4 17:46:12 tofu avahi-daemon[1176]: Leaving mDNS multicast group on interface wlan0.IPv4 with address 192.168.1.2. May 4 17:46:12 tofu avahi-daemon[1176]: Interface wlan0.IPv4 no longer relevant for mDNS. May 4 17:46:12 tofu NetworkManager: <info> Policy set 'Auto eth0' (eth0) as default for routing and DNS. May 4 17:46:12 tofu NetworkManager: <info> (wlan0): cleaning up... May 4 17:46:12 tofu NetworkManager: <info> (wlan0): taking down device. May 4 17:46:12 tofu avahi-daemon[1176]: Withdrawing address record for 2002:4c6e:638a:0:1e4b:d6ff:fe78:951d on wlan0. May 4 17:46:12 tofu wpa_supplicant[1212]: CTRL-EVENT-DISCONNECTED - Disconnect event - remove keys May 4 17:46:13 tofu NetworkManager: <info> (eth0): now unmanaged May 4 17:46:13 tofu NetworkManager: <info> (eth0): device state change: 8 -> 1 (reason 37) May 4 17:46:13 tofu NetworkManager: <info> (eth0): deactivating device (reason: 37). May 4 17:46:13 tofu NetworkManager: <info> (eth0): canceled DHCP transaction, dhcp client pid 1559 May 4 17:46:13 tofu NetworkManager: <WARN> check_one_route(): (eth0) error -34 returned from rtnl_route_del(): Sucess#012 May 4 17:46:13 tofu avahi-daemon[1176]: Withdrawing address record for 192.168.1.3 on eth0. May 4 17:46:13 tofu avahi-daemon[1176]: Leaving mDNS multicast group on interface eth0.IPv4 with address 192.168.1.3. May 4 17:46:13 tofu avahi-daemon[1176]: Interface eth0.IPv4 no longer relevant for mDNS. May 4 17:46:13 tofu NetworkManager: <info> (eth0): cleaning up... May 4 17:46:13 tofu NetworkManager: <info> (eth0): taking down device. May 4 17:46:13 tofu avahi-daemon[1176]: Withdrawing address record for 2002:4c6e:638a:0:4a5b:39ff:fe0b:325d on eth0. May 4 17:46:13 tofu NetworkManager: <info> (eth0): carrier now OFF (device state 1)

    Read the article

  • Nginx & Apache Cannot get try_files to work with permalinks

    - by tcherokee
    I have been working on this for the past two weeks not and for some reason I cannot seem to get nginx's try_files to work with my wordpress permalinks. I am hoping someone will be able to tell me where I am going wrong and also hopefully tell me if I made any major errors with my configurations as well (I am an nginx newbie... but learning :) ). Here are my Configuration files nginx.conf user www-data; worker_processes 4; pid /var/run/nginx.pid; events { worker_connections 768; # multi_accept on; } http { ## # Basic Settings ## sendfile on; tcp_nopush on; tcp_nodelay on; keepalive_timeout 65; types_hash_max_size 2048; # server_tokens off; # server_names_hash_bucket_size 64; # server_name_in_redirect off; include /etc/nginx/mime.types; default_type application/octet-stream; ## # Logging Settings ## # Defines the cache log format, cache log location # and the main access log location. log_format cache '***$time_local ' '$upstream_cache_status ' 'Cache-Control: $upstream_http_cache_control ' 'Expires: $upstream_http_expires ' '$host ' '"$request" ($status) ' '"$http_user_agent" ' ; access_log /var/log/nginx/access.log; error_log /var/log/nginx/error.log; include /etc/nginx/conf.d/*.conf; include /etc/nginx/sites-enabled/*; } mydomain.com.conf server { listen 123.456.78.901:80; # IP goes here. server_name www.mydomain.com mydomain.com; #root /var/www/mydomain.com/prod; index index.php; ## mydomain.com -> www.mydomain.com (301 - Permanent) if ($host !~* ^(www|dev)) { rewrite ^/(.*)$ $scheme://www.$host/$1 permanent; } # Add trailing slash to */wp-admin requests. rewrite /wp-admin$ $scheme://$host$uri/ permanent; # All media (including uploaded) is under wp-content/ so # instead of caching the response from apache, we're just # going to use nginx to serve directly from there. location ~* ^/(wp-content|wp-includes)/(.*)\.(jpg|png|gif|jpeg|css|js|m$ root /var/www/mydomain.com/prod; } # Don't cache these pages. location ~* ^/(wp-admin|wp-login.php) { proxy_pass http://backend; } location / { if ($http_cookie ~* "wordpress_logged_in_[^=]*=([^%]+)%7C") { set $do_not_cache 1; } proxy_cache_key "$scheme://$host$request_uri $do_not_cache"; proxy_cache main; proxy_pass http://backend; proxy_cache_valid 30m; # 200, 301 and 302 will be cached. # Fallback to stale cache on certain errors. # 503 is deliberately missing, if we're down for maintenance # we want the page to display. #try_files $uri $uri/ /index.php?q=$uri$args; #try_files $uri =404; proxy_cache_use_stale error timeout invalid_header http_500 http_502 http_504 http_404; } # Cache purge URL - works in tandem with WP plugin. # location ~ /purge(/.*) { # proxy_cache_purge main "$scheme://$host$1"; # } # No access to .htaccess files. location ~ /\.ht { deny all; } } # End server gzip.conf # Gzip Configuration. gzip on; gzip_disable msie6; gzip_static on; gzip_comp_level 4; gzip_proxied any; gzip_types text/plain text/css application/x-javascript text/xml application/xml application/xml+rss text/javascript; proxy.conf # Set proxy headers for the passthrough proxy_redirect off; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_max_temp_file_size 0; client_max_body_size 10m; client_body_buffer_size 128k; proxy_connect_timeout 90; proxy_send_timeout 90; proxy_read_timeout 90; proxy_buffer_size 4k; proxy_buffers 4 32k; proxy_busy_buffers_size 64k; proxy_temp_file_write_size 64k; add_header X-Cache-Status $upstream_cache_status; backend.conf upstream backend { # Defines backends. # Extracting here makes it easier to load balance # in the future. Needs to be specific IP as Plesk # doesn't have Apache listening on localhost. ip_hash; server 127.0.0.1:8001; # IP goes here. } cache.conf # Proxy cache and temp configuration. proxy_cache_path /var/www/nginx_cache levels=1:2 keys_zone=main:10m max_size=1g inactive=30m; proxy_temp_path /var/www/nginx_temp; proxy_cache_key "$scheme://$host$request_uri"; proxy_redirect off; # Cache different return codes for different lengths of time # We cached normal pages for 10 minutes proxy_cache_valid 200 302 10m; proxy_cache_valid 404 1m; The two commented out try_files in location \ of the mydomain config files are the ones I tried. This error I found in the error log can be found below. ...rewrite or internal redirection cycle while internally redirecting to "/index.php" Thanks in advance

    Read the article

  • local user cannot access vsftpd server

    - by Zloy Smiertniy
    I'm currently running a vsftpd server and I added the necessary configurations in vsftpd.conf so that local users can use clients like FileZilla to manage their homes in a server. I found out that only users in the sudoers list access without a problem only they can't download the files, but users that are not sudoers cannot even access their homes from a client but they can access by a web browser using the FTP protocol and they can only access their home directories (as intented) Im running a fedora 14 on my server and my vsftpd.conf looks like this: # Example config file /etc/vsftpd/vsftpd.conf # # The default compiled in settings are fairly paranoid. This sample file # loosens things up a bit, to make the ftp daemon more usable. # Please see vsftpd.conf.5 for all compiled in defaults. # # READ THIS: This example file is NOT an exhaustive list of vsftpd options. # Please read the vsftpd.conf.5 manual page to get a full idea of vsftpd's # capabilities. # # Allow anonymous FTP? (Beware - allowed by default if you comment this out). anonymous_enable=NO # # Uncomment this to allow local users to log in. local_enable=YES # # Uncomment this to enable any form of FTP write command. write_enable=YES # # Default umask for local users is 077. You may wish to change this to 022, # if your users expect that (022 is used by most other ftpd's) local_umask=022 # # Uncomment this to allow the anonymous FTP user to upload files. This only # has an effect if the above global write enable is activated. Also, you will # obviously need to create a directory writable by the FTP user. #anon_upload_enable=YES # # Uncomment this if you want the anonymous FTP user to be able to create # new directories. #anon_mkdir_write_enable=YES # # Activate directory messages - messages given to remote users when they # go into a certain directory. dirmessage_enable=YES # # The target log file can be vsftpd_log_file or xferlog_file. # This depends on setting xferlog_std_format parameter xferlog_enable=YES # # Make sure PORT transfer connections originate from port 20 (ftp-data). connect_from_port_20=YES # # If you want, you can arrange for uploaded anonymous files to be owned by # a different user. Note! Using "root" for uploaded files is not # recommended! #chown_uploads=YES #chown_username=whoever # # The name of log file when xferlog_enable=YES and xferlog_std_format=YES # WARNING - changing this filename affects /etc/logrotate.d/vsftpd.log #xferlog_file=/var/log/xferlog # # Switches between logging into vsftpd_log_file and xferlog_file files. # NO writes to vsftpd_log_file, YES to xferlog_file xferlog_std_format=YES # # You may change the default value for timing out an idle session. #idle_session_timeout=600 # # You may change the default value for timing out a data connection. #data_connection_timeout=120 # # It is recommended that you define on your system a unique user which the # ftp server can use as a totally isolated and unprivileged user. #nopriv_user=ftpsecure # # Enable this and the server will recognise asynchronous ABOR requests. Not # recommended for security (the code is non-trivial). Not enabling it, # however, may confuse older FTP clients. #async_abor_enable=YES # # By default the server will pretend to allow ASCII mode but in fact ignore # the request. Turn on the below options to have the server actually do ASCII # mangling on files when in ASCII mode. # Beware that on some FTP servers, ASCII support allows a denial of service # attack (DoS) via the command "SIZE /big/file" in ASCII mode. vsftpd # predicted this attack and has always been safe, reporting the size of the # raw file. # ASCII mangling is a horrible feature of the protocol. ascii_upload_enable=YES ascii_download_enable=YES # # You may fully customise the login banner string: ftpd_banner=Welcome to GAMBITA FTP service # # You may specify a file of disallowed anonymous e-mail addresses. Apparently # useful for combatting certain DoS attacks. #deny_email_enable=YES # (default follows) #banned_email_file=/etc/vsftpd/banned_emails # # You may specify an explicit list of local users to chroot() to their home # directory. If chroot_local_user is YES, then this list becomes a list of # users to NOT chroot(). chroot_local_user=YES chroot_list_enable=YES # (default follows) chroot_list_file=/etc/vsftpd/chroot_list # # You may activate the "-R" option to the builtin ls. This is disabled by # default to avoid remote users being able to cause excessive I/O on large # sites. However, some broken FTP clients such as "ncftp" and "mirror" assume # the presence of the "-R" option, so there is a strong case for enabling it. ls_recurse_enable=YES # # When "listen" directive is enabled, vsftpd runs in standalone mode and # listens on IPv4 sockets. This directive cannot be used in conjunction # with the listen_ipv6 directive. listen=YES # # This directive enables listening on IPv6 sockets. To listen on IPv4 and IPv6 # sockets, you must run two copies of vsftpd with two configuration files. # Make sure, that one of the listen options is commented !! #listen_ipv6=YES pam_service_name=vsftpd userlist_enable=YES tcp_wrappers=YES use_localtime=YES Anyone has an idea of what might be happening? Nothing concerning vsftpd is written in any log

    Read the article

  • DNS and name server in centos 6.3 64 bit is not pinged out side

    - by user135855
    I got a problem with centOS 6.3 64-bit. I want to setup my nameserver with bind here. I am listing all my configuration [root@izyon92 ~]# cat/etc/hosts -------------- 127.0.0.1 localhost localhost.localdomain localhost4 localhost4.localdomain4 ::1 localhost localhost.localdomain localhost6 localhost6.localdomain6 182.19.26.92 izyon92.zyonize1.com izyon92 [root@izyon92 ~]# cat /etc/sysconfig/network --------------------------------------------- NETWORKING=yes HOSTNAME=izyon92.zyonize1.com GATEWAY=182.19.26.89 [root@izyon92 ~]# cat /etc/resolv.conf -------------------------------------------- # Generated by NetworkManager search zyonize1.com nameserver 182.19.26.92 [root@izyon92 ~]# cat /etc/named.conf -------------------------------------------- // // named.conf // // Provided by Red Hat bind package to configure the ISC BIND named(8) DNS // server as a caching only nameserver (as a localhost DNS resolver only). // // See /usr/share/doc/bind*/sample/ for example named configuration files. // options { #listen-on port 53 { 127.0.0.1; }; listen-on-v6 port 53 { none; }; directory "/var/named"; dump-file "/var/named/data/cache_dump.db"; statistics-file "/var/named/data/named_stats.txt"; memstatistics-file "/var/named/data/named_mem_stats.txt"; allow-query { 182.19.26.92; }; recursion yes; dnssec-enable yes; dnssec-validation yes; dnssec-lookaside auto; /* Path to ISC DLV key */ bindkeys-file "/etc/named.iscdlv.key"; managed-keys-directory "/var/named/dynamic"; }; logging { channel default_debug { file "data/named.run"; severity dynamic; }; }; zone "." IN { type hint; file "named.ca"; }; include "/etc/named.rfc1912.zones"; include "/etc/named.root.key"; [root@izyon92 ~]# cat /etc/named.rfc1912.zones -------------------------------------------------- // named.rfc1912.zones: // // Provided by Red Hat caching-nameserver package // // ISC BIND named zone configuration for zones recommended by // RFC 1912 section 4.1 : localhost TLDs and address zones // and http://www.ietf.org/internet-drafts/draft-ietf-dnsop-default-local-zones-02.txt // (c)2007 R W Franks // // See /usr/share/doc/bind*/sample/ for example named configuration files. // zone "localhost.localdomain" IN { type master; file "named.localhost"; allow-update { none; }; }; zone "localhost" IN { type master; file "named.localhost"; allow-update { none; }; }; zone "1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.ip6.arpa" IN { type master; file "named.loopback"; allow-update { none; }; }; zone "1.0.0.127.in-addr.arpa" IN { type master; file "named.loopback"; allow-update { none; }; }; zone "0.in-addr.arpa" IN { type master; file "named.empty"; allow-update { none; }; }; zone "zyonize1.com" { type master; file "/var/named/zyonize.com.hosts"; }; [root@izyon92 ~]# cat /var/named/zyonize.com.hosts --------------------------------------------------------- $ttl 38400 zyonize1.com. IN SOA 182.19.26.92. dev\.izyon.gmail.com. ( 1347436958 10800 3600 604800 38400 ) zyonize1.com. IN NS 182.19.26.92. zyonize1.com. IN A 182.19.26.92 www.zyonize1.com. IN A 182.19.26.92 izyon92.zyonize1.com. IN A 182.19.26.92 I have disabled selinux and stopped iptables. dig and nslookup is working fine in the same machine [root@izyon92 ~]# dig zyonize1.com ---------------------------------------- ; <<>> DiG 9.8.2rc1-RedHat-9.8.2-0.10.rc1.el6_3.2 <<>> zyonize1.com ;; global options: +cmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 55751 ;; flags: qr aa rd ra; QUERY: 1, ANSWER: 1, AUTHORITY: 1, ADDITIONAL: 0 ;; QUESTION SECTION: ;zyonize1.com. IN A ;; ANSWER SECTION: zyonize1.com. 38400 IN A 182.19.26.92 ;; AUTHORITY SECTION: zyonize1.com. 38400 IN NS 182.19.26.92. ;; Query time: 0 msec ;; SERVER: 182.19.26.92#53(182.19.26.92) ;; WHEN: Fri Sep 14 00:09:19 2012 ;; MSG SIZE rcvd: 72 [root@izyon92 ~]# nslookup zyonize1.com ---------------------------------------------- Server: 182.19.26.92 Address: 182.19.26.92#53 Name: zyonize1.com Address: 182.19.26.92 But here is the problem I am facing, I have windows machine, to test this dns and nameserver I set the first IPv4 DNS server to 182.19.26.92. Here is the details Connection-specific DNS Suffix: Description: Realtek PCIe GBE Family Controller Physical Address: ?14-FE-B5-9F-3A-A8 DHCP Enabled: No IPv4 Address: 192.168.2.50 IPv4 Subnet Mask: 255.255.255.0 IPv4 Default Gateway: 192.168.2.1 IPv4 DNS Servers: 182.19.26.92, 182.19.95.66 IPv4 WINS Server: NetBIOS over Tcpip Enabled: Yes Link-local IPv6 Address: fe80::45cc:2ada:c13:ca42%16 IPv6 Default Gateway: IPv6 DNS Server: when I am pining from this machine it is not finding the server. Where as in another server with another live IP with Fedora ping is working fine.

    Read the article

  • Why are my USB 2.0 devices crashing Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a generic ATX motherboard with no identifying markings other than one stamp that says "Rev.B". CPU-Z identifies the motherboard model as VT8601 but doesn't provide me with any manufacturer name. On board it has 1 x 10/100 LAN, 2 x USB 1.0, VGA, PS/2 for KB and mouse, parallel port, 2 x serial ports, 2 x IDE, 1 x floppy, 2 x SDRAM slots, 1 x CPU housing that is seating a 1.3GHz Intel Celeron CPU, 3 x PCI, 1 x AGP - although you can only use 2 of the PCI slots if you use the AGP slot due to the physical layout of the board. It's got 768Mb PC133 SDRAM - 1 x 512Mb & 1 x 256Mb installed as well as a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board containing 3 x external + 1 x internal USB connectors. It has a DVD+/-RW running as master on IDE1 and a 1.44Mb 3.5" floppy drive connected to the floppy connector. It has an 80Gb Western Digital hard drive running as master on IDE0. All this is sitting in a slimline case. I don't know the wattage of the PSU, but can post this later if this proves to be helpful. The motherboard is running a version of Award BIOS for which I don't have the version number to hand but can again post this later if it would be helpful. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine?

    Read the article

  • Why is Varnish not caching?

    - by Justin
    I am troubleshooting the setup of Varnish 3.x on my Ubuntu server. I'm running Drupal 7 on two sites set up on the box, via named-based vhosts. Before trying to get Varnish to play nice with Drupal I'm trying to just get Varnish to a PNG from cache. Here are the headers I get from a curl -I request of the PNG file: HTTP/1.1 200 OK Server: Apache/2.2.22 (Ubuntu) Last-Modified: Sun, 07 Oct 2012 21:18:59 GMT ETag: "a57c2-3850-4cb7ea73db6c0" Accept-Ranges: bytes Content-Length: 14416 Cache-Control: max-age=1209600 Expires: Thu, 25 Oct 2012 22:55:14 GMT Content-Type: image/png Accept-Ranges: bytes Date: Thu, 11 Oct 2012 22:55:14 GMT X-Varnish: 1766703058 Age: 0 Via: 1.1 varnish Connection: keep-alive X-Varnish-Cache: MISS Here is the Varnish VCL file I'm using (It's a default VCL configuration designed for Drupal): # Default backend definition. Set this to point to your content # server. # backend default { .host = "127.0.0.1"; .port = "8080"; } # Respond to incoming requests. sub vcl_recv { # Use anonymous, cached pages if all backends are down. if (!req.backend.healthy) { unset req.http.Cookie; } # Allow the backend to serve up stale content if it is responding slowly. set req.grace = 6h; # Pipe these paths directly to Apache for streaming. #if (req.url ~ "^/admin/content/backup_migrate/export") { # return (pipe); #} # Do not cache these paths. if (req.url ~ "^/status\.php$" || req.url ~ "^/update\.php$" || req.url ~ "^/admin$" || req.url ~ "^/admin/.*$" || req.url ~ "^/flag/.*$" || req.url ~ "^.*/ajax/.*$" || req.url ~ "^.*/ahah/.*$") { return (pass); } # Do not allow outside access to cron.php or install.php. #if (req.url ~ "^/(cron|install)\.php$" && !client.ip ~ internal) { # Have Varnish throw the error directly. # error 404 "Page not found."; # Use a custom error page that you've defined in Drupal at the path "404". # set req.url = "/404"; #} # Always cache the following file types for all users. This list of extensions # appears twice, once here and again in vcl_fetch so make sure you edit both # and keep them equal. if (req.url ~ "(?i)\.(pdf|asc|dat|txt|doc|xls|ppt|tgz|csv|png|gif|jpeg|jpg|ico|swf|css|js)(\?.*)?$") { unset req.http.Cookie; } # Remove all cookies that Drupal doesn't need to know about. We explicitly # list the ones that Drupal does need, the SESS and NO_CACHE. If, after # running this code we find that either of these two cookies remains, we # will pass as the page cannot be cached. if (req.http.Cookie) { # 1. Append a semi-colon to the front of the cookie string. # 2. Remove all spaces that appear after semi-colons. # 3. Match the cookies we want to keep, adding the space we removed # previously back. (\1) is first matching group in the regsuball. # 4. Remove all other cookies, identifying them by the fact that they have # no space after the preceding semi-colon. # 5. Remove all spaces and semi-colons from the beginning and end of the # cookie string. set req.http.Cookie = ";" + req.http.Cookie; set req.http.Cookie = regsuball(req.http.Cookie, "; +", ";"); set req.http.Cookie = regsuball(req.http.Cookie, ";(SESS[a-z0-9]+|SSESS[a-z0-9]+|NO_CACHE)=", "; \1="); set req.http.Cookie = regsuball(req.http.Cookie, ";[^ ][^;]*", ""); set req.http.Cookie = regsuball(req.http.Cookie, "^[; ]+|[; ]+$", ""); if (req.http.Cookie == "") { # If there are no remaining cookies, remove the cookie header. If there # aren't any cookie headers, Varnish's default behavior will be to cache # the page. unset req.http.Cookie; } else { # If there is any cookies left (a session or NO_CACHE cookie), do not # cache the page. Pass it on to Apache directly. return (pass); } } } # Set a header to track a cache HIT/MISS. sub vcl_deliver { if (obj.hits > 0) { set resp.http.X-Varnish-Cache = "HIT"; } else { set resp.http.X-Varnish-Cache = "MISS"; } } # Code determining what to do when serving items from the Apache servers. # beresp == Back-end response from the web server. sub vcl_fetch { # We need this to cache 404s, 301s, 500s. Otherwise, depending on backend but # definitely in Drupal's case these responses are not cacheable by default. if (beresp.status == 404 || beresp.status == 301 || beresp.status == 500) { set beresp.ttl = 10m; } # Don't allow static files to set cookies. # (?i) denotes case insensitive in PCRE (perl compatible regular expressions). # This list of extensions appears twice, once here and again in vcl_recv so # make sure you edit both and keep them equal. if (req.url ~ "(?i)\.(pdf|asc|dat|txt|doc|xls|ppt|tgz|csv|png|gif|jpeg|jpg|ico|swf|css|js)(\?.*)?$") { unset beresp.http.set-cookie; } # Allow items to be stale if needed. set beresp.grace = 6h; } # In the event of an error, show friendlier messages. sub vcl_error { # Redirect to some other URL in the case of a homepage failure. #if (req.url ~ "^/?$") { # set obj.status = 302; # set obj.http.Location = "http://backup.example.com/"; #} # Otherwise redirect to the homepage, which will likely be in the cache. set obj.http.Content-Type = "text/html; charset=utf-8"; synthetic {" <html> <head> <title>Page Unavailable</title> <style> body { background: #303030; text-align: center; color: white; } #page { border: 1px solid #CCC; width: 500px; margin: 100px auto 0; padding: 30px; background: #323232; } a, a:link, a:visited { color: #CCC; } .error { color: #222; } </style> </head> <body onload="setTimeout(function() { window.location = '/' }, 5000)"> <div id="page"> <h1 class="title">Page Unavailable</h1> <p>The page you requested is temporarily unavailable.</p> <p>We're redirecting you to the <a href="/">homepage</a> in 5 seconds.</p> <div class="error">(Error "} + obj.status + " " + obj.response + {")</div> </div> </body> </html> "}; return (deliver); } I'm getting a MISS and age 0 every time. If I'm understanding correctly, this means the file isn't being returned from Varnish's cache. Is there a problem with my Varnish config?

    Read the article

  • System user authentication via web interface [closed]

    - by donodarazao
    Background: We have one pretty slow and expensive satellite Internet connection that is shared in a network with 5-50 users. To limit traffic, users shall pay a certain sum of money per hour. Routing and traffic accounting on user basis is done by a opensuse 10.3 server. Login is done via pppoe, and for each connection, username, bytes_sent, bytes_rcvd, start_time, end_time,etc are written into a mysql database. Now it was decided that we want to change from time-based to volume-based pricing. As the original developer who installed the system a couple of years ago isn't available, I'm trying to do the changes. Although I'm absolutely new to all this, there is some progress. However, there's one point I'm absolutely stuck. Up to now, only administrators can access connection details and billing information via a web interface. But as volume-based prices are less transparent to users than time-based prices, it is essential that users themselves can check their connections and how much they cost via the web interface. For this, we need some kind of user authentication. Actual question: How to develop such a user authentication? Every user has a linux system user account. With this user name and password, connection to the pppoe-server is made by the client machines. I thought about two possibles ways to authenticate users: First possibility: Users type username and password in a form. This is then somehow checked. We already have to possibilities to change passwords via the web interface. Here are parts of the code: Part of the Perl script the homepage is linked to: #!/usr/bin/perl use CGI; use CGI::Carp qw(fatalsToBrowser); use lib '../lib'; use own_perl_module; my @error; my $data; $query = new CGI; $username = $query->param('username') || ''; $oldpasswd = $query->param('oldpasswd') || ''; $passwd = $query->param('passwd') || ''; $passwd2 = $query->param('passwd2') || ''; own_perl_module::connect(); if ($query->param('submit')) { my $benutzer = own_perl_module::select_benutzer(username => $username) or push @error, "user not exists"; push @error, "your password?!?" unless $passwd; unless (@error) { own_perl_module::update_benutzer($benutzer->{id}, { oldpasswd => $oldpasswd, passwd => $passwd, passwd2 => $passwd2 }, error => \@error) and push @error, "Password changed."; } } Here's part of the sub update_benutzer in the own_perl_module: if ($dat-{passwd} ne '') { my $username = $dat-{username} || $select-{username}; my $system = "./chpasswd.pl '$username' '$dat-{passwd}'" . (defined($dat-{oldpasswd}) ? " '$dat-{oldpasswd}'" : undef); my $answer = $system; if ($? != 0) { chomp($answer); push @$error, $answer || "error changing password ($?)"; Here's chpasswd.pl: #!/usr/bin/perl use FileHandle; use IPC::Open3; local $username = shift; local $passwd = shift; local $oldpasswd = shift; local $chat = { 'Old Password: $' => sub { print POUT "$oldpasswd\n"; }, 'New password: $' => sub { print POUT "$passwd\n"; }, 'Re-enter new password: $' => sub { print POUT "$passwd\n"; }, '(.*)\n$' => sub { print "$1\n"; exit 1; } }; local $/ = \1; my $command; if (defined($oldpasswd)) { $command = "sudo -u '$username' /usr/bin/passwd"; } else { $command = "sudo /usr/bin/passwd '$username'"; } $pid = open3(\*POUT, \*PIN, \*PERR, $command) or die; my $buffer; LOOP: while($_ = <PERR>) { $buffer .= $_; foreach (keys(%$chat)) { if ($buffer =~ /$_/i) { $buffer = undef; &{$chat->{$_}}; } } } exit; Could this somehow be adjusted to verify users, but not changing user passwords? The second possibility I see: all pppoe connections are logged in the mysql database. If I could somehow retrieve the username (or uid) of the user connected by pppoe, this could be used to authenticate users. Users could only check their internet connections and costs when they are online (and thus paying money), but this could be tolerated. Here's a line of the script that inserts connections into the database: my $username = $ENV{PEERNAME}; I thought it would be easy to use this variable, but $username seems to be always empty in test-scripts (print $username). Any idea how to retrieve the user connected to the pppoe server? Sorry for the long question! Any help would be very much appreciated. :)

    Read the article

  • Why are my USB 2.0 devices hanging Windows XP?

    - by BenAlabaster
    Background on the machine I'm having a problem with: The machine was inherited and appears to be circa 2003 (there's a date stamp on the power supply which leads me to this conclusion). I've got it set up as a Skype terminal for my 2 year old to keep in touch with her grandparents and other members of the family - which everyone loves. It has a generic ATX motherboard with no identifying markings other than one stamp that says "Rev.B". CPU-Z identifies the motherboard model as VT8601 but doesn't provide me with any manufacturer name. On board it has 1 x 10/100 LAN, 2 x USB 1.0, VGA, PS/2 for KB and mouse, parallel port, 2 x serial ports, 2 x IDE, 1 x floppy, 2 x SDRAM slots, 1 x CPU housing that is seating a 1.3GHz Intel Celeron CPU, 3 x PCI, 1 x AGP - although you can only use 2 of the PCI slots if you use the AGP slot due to the physical layout of the board. It's got 768Mb PC133 SDRAM - 1 x 512Mb & 1 x 256Mb installed as well as a D-LINK WDA-2320 54G Wi-Fi network card and a generic USB 2.0 expansion board containing 3 x external + 1 x internal USB connectors - it has a NEC uPD720102 chipset. It has a DVD+/-RW running as master on IDE1 and a 1.44Mb 3.5" floppy drive connected to the floppy connector. It has an 80Gb Western Digital hard drive running as master on IDE0. All this is sitting in a slimline case. I don't know the wattage of the PSU, but can post this later if this proves to be helpful. The motherboard is running a version of Award BIOS for which I don't have the version number to hand but can again post this later if it would be helpful. The hard disk is freshly formatted and built with Windows XP Professional/Service Pack 3 and is up to date with all current patches. In addition to Windows XP, the only other software it's running is Skype 4.1 (4.2 hangs the whole machine as soon as it starts up, requiring a hard boot to recover). It's got a Daytek MV150 15" touch screen hooked up to the on board VGA and COM1 sockets with the most current drivers from the Daytek website and the most current version of ELO-Touchsystems drivers for the touch component. The webcam is a Logitech Webcam C200 with the latest drivers from the Logitech website. The problem: If I hook any devices to the USB 2.0 sockets, it hangs the whole machine and I have to hard boot it to get it back up. If I have any devices attached to the USB 2.0 sockets when I boot up, it hangs before Windows gets to the login prompt and I have to hard boot it to recover. Workarounds found: I can plug the same devices into the on board USB 1.0 sockets and everything works fine, albeit at reduced performance. I've tried 3 different kinds of USB thumb drives, 3 different makes/models of webcams and my iPhone all with the same effect. They're recognized and don't hang the machine when I hook them to the USB 1.0 but if I hook them to the USB 2.0 ports, the machine hangs within a couple of seconds of recognizing the devices were connected. Attempted solutions: I've seen suggestions that this could be a power problem - that the PSU just doesn't have the wattage to drive these ports. While I'm doubtful this is the problem [after all the motherboard has the same standard connector regardless of the PSU wattage], I tried disabling all the on board devices that I'm not using - on board LAN, the second COM port, the AGP connector etc. through the BIOS in what I'm sure is a futile attempt to reduce the power consumption... I also modified the ACPI and power management settings. It didn't have any noticeable affect, although it didn't do any harm either. Could the wattage of the PSU really cause this problem? If it can, is there anything I need to be aware of when replacing it or do I just need to make sure it's got a higher wattage than the current one? My interpretation was that the wattage only affected the number of drives you could hook up to the power connectors, is that right? I've installed the USB card in another machine and it works without issue, so it's not a problem with the USB card itself, and Windows says the card is installed and working correctly... right up until I connect a device to it. The only thing I haven't done which I only just thought of while writing this essay is trying the USB 2.0 card in a different PCI slot, or re-ordering the wi-fi and USB cards in the slots... although I'm not sure if this will make any difference - does anyone have any experience that would suggest this might work? Other thoughts/questions: Perhaps this is an incompatibility between the USB 2.0 card and the BIOS, would re-flashing the BIOS with a newer version help? Do I need to be able to identify the manufacturer of the motherboard in order to be able to find a BIOS edition specific for this motherboard or will any version of Award BIOS function in its place? Question: Does anyone have any ideas that could help me get my USB 2.0 devices hooked up to this machine? Edit: Updated the USB 2.0 info with reference to actual card - http://www.xpcgear.com/lpnec4u.html

    Read the article

  • DNS works only with ip but does not work with NS CentOS + Bind9

    - by Borislav Yordanov
    I am having a headache with DNS. Lets say my public IP is 1.2.3.4, my local IP is 192.168.0.10 and my domain is example.com I am running CentOS on a virtual machine (Parallels Desktop for Mac) with a LAN card reserved for it, so it gets Ip directly from the router. I have ports 80,443,53 forwarded to 192.168.0.10. Both Mac OS and CentOs firewalls are Off. The strange is when I type dig @1.2.3.4 example.com from my other PC I get: ; <<>> DiG 9.8.3-P1 <<>> @1.2.3.4 example.com ; (1 server found) ;; global options: +cmd ;; Got answer: ;; ->>HEADER<<- opcode: QUERY, status: NOERROR, id: 16941 ;; flags: qr aa rd; QUERY: 1, ANSWER: 1, AUTHORITY: 2, ADDITIONAL: 2 ;; WARNING: recursion requested but not available ;; QUESTION SECTION: ;example.com. IN A ;; ANSWER SECTION: example.com. 86400 IN A 1.2.3.4 ;; AUTHORITY SECTION: example.com. 86400 IN NS ns2.example.com. example.com. 86400 IN NS ns1.example.com. ;; ADDITIONAL SECTION: ns1.example.com. 86400 IN A 1.2.3.4 ns2.example.com. 86400 IN A 1.2.3.4 ;; Query time: 8 msec ;; SERVER: 1.2.3.4#53(1.2.3.4) ;; WHEN: Sat Nov 2 09:37:36 2013 ;; MSG SIZE rcvd: 109 but when i type: dig @ns1.example.com example.com it waits a few seconds and returns dig: couldn't get address for 'ns1.dsht.in': not found This is my config file: /etc/named.conf options { listen-on-v6 { none; }; directory"/var/named"; dump-file"/var/named/data/cache_dump.db"; statistics-file"/var/named/data/named_stats.txt"; memstatistics-file"/var/named/data/named_mem_stats.txt"; allow-query{ localhost; 192.168.0.0/24; }; allow-transfer { localhost; 192.168.0.0/24; }; recursion yes; dnssec-enable yes; dnssec-validation yes; dnssec-lookaside auto; bindkeys-file "/etc/named.iscdlv.key"; managed-keys-directory "/var/named/dynamic"; }; logging { channel default_debug { file "data/named.run"; severity dynamic; }; }; # change all from here view "internal" { match-clients { localhost; 192.168.0.0/24; }; zone "." IN { type hint; file "named.ca"; }; zone "example.com" IN { type master; file "example.com.zone"; allow-update { none; }; }; zone "0.168.192.in-addr.arpa" IN { type master; file "0.168.192.in-addr.arpa"; allow-update { none; }; }; include "/etc/named.rfc1912.zones"; include "/etc/named.root.key"; }; view "external" { match-clients { any; }; allow-query { any; }; recursion no; zone "example.com" IN { type master; file "example.com.zone"; allow-update { none; }; }; zone "4.3.2.1.in-addr.arpa" IN { type master; file "4.3.2.1.in-addr.arpa"; allow-update { none; }; }; }; /var/named/exmaple.com.zone $TTL 86400 @ IN SOA ns1.example.com. host.example.com. ( 2013042201 ;Serial 3600 ;Refresh 1800 ;Retry 604800 ;Expire 86400 ;Minimum TTL ) ; Specify our two nameservers IN NS ns1.example.com. IN NS ns2.example.com. ; Resolve nameserver hostnames to IP, replace with your two droplet IP addresses. ns1 IN A 1.2.3.4 ns2 IN A 1.2.3.4 ; Define hostname -> IP pairs which you wish to resolve @ IN A 1.2.3.4 IN A 1.2.3.4 www IN A 1.2.3.4 server2 IN A 192.168.0.2 * IN A 1.2.3.4 /var/named/4.3.2.1.in-addr.arpa $TTL 2d ; 172800 seconds $ORIGIN 4.3.2.1.IN-ADDR.ARPA. @ IN SOA ns1.example.com. host.example.com. ( 2013010304 ; serial number 3h ; refresh 15m ; update retry 3w ; expiry 3h ; nx = nxdomain ttl ) IN NS ns1.example.com. IN NS ns2.example.com. IN PTR example.com. ; etc /var/named/0.168.192.in-addr.arpa $TTL 2d ; 172800 seconds $ORIGIN 0.168.192.IN-ADDR.ARPA. @ IN SOA ns1.example.com. host.example.com. ( 2013010304 ; serial number 3h ; refresh 15m ; update retry 3w ; expiry 3h ; nx = nxdomain ttl ) IN NS ns1.example.com. IN NS ns2.example.com. 10 IN PTR example.com. 2 IN PTR server2.example.com ; etc I will be very glad if someone can help me. Thank you in advance

    Read the article

  • Error 5 partition table invalid or corrupt

    - by Clodoaldo
    I'm trying to add a second SSD to a Centos 6 system. But I get the Error 5 partition table invalid or corrupt at boot. The system already has a single SSD (sdb) and a pair of HDDs (sd{a,c}) in a RAID 1 array from where it boots. It is as if the new SSD assumes one of the devices of the RAID array. Is it? How to avoid that or rearrange the setup? # cat fstab UUID=967b4035-782d-4c66-b22f-50244fe970ca / ext4 defaults 1 1 UUID=86fd06e9-cdc9-4166-ba9f-c237cfc43e02 /boot ext4 defaults 1 2 UUID=72552a7a-d8ae-4f0a-8917-b75a6239ce9f /ssd ext4 discard,relatime 1 2 UUID=8000e5e6-caa2-4765-94f8-9caeb2bda26e swap swap defaults 0 0 tmpfs /dev/shm tmpfs defaults 0 0 devpts /dev/pts devpts gid=5,mode=620 0 0 sysfs /sys sysfs defaults 0 0 proc /proc proc defaults 0 0 # ll /dev/disk/by-id/ total 0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX-part1 -> ../../sdb1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-ST3500413AS_5VMT49E3 -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:0 -> ../../md0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:1 -> ../../md1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:2 -> ../../md2 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-a04d7241:8da6023e:f9004352:107a923a -> ../../md1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-a22c43b9:f1954990:d3ddda5e:f9aff3c9 -> ../../md0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-f403a2d0:447803b5:66edba73:569f8305 -> ../../md2 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX-part1 -> ../../sdb1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3 -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5000c500383621ff -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5000c5003838b2e7 -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5e83a97f592139d6 -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5e83a97f592139d6-part1 -> ../../sdb1 # fdisk -l Disk /dev/sdb: 120.0 GB, 120034123776 bytes 255 heads, 63 sectors/track, 14593 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x79298ec9 Device Boot Start End Blocks Id System /dev/sdb1 1 14594 117219328 83 Linux Disk /dev/sdc: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000d99de Device Boot Start End Blocks Id System /dev/sdc1 1 1275 10240000 fd Linux raid autodetect /dev/sdc2 * 1275 1339 512000 fd Linux raid autodetect /dev/sdc3 1339 60802 477633536 fd Linux raid autodetect Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000b3327 Device Boot Start End Blocks Id System /dev/sda1 1 1275 10240000 fd Linux raid autodetect /dev/sda2 * 1275 1339 512000 fd Linux raid autodetect /dev/sda3 1339 60802 477633536 fd Linux raid autodetect Disk /dev/md0: 10.5 GB, 10484641792 bytes 2 heads, 4 sectors/track, 2559727 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table Disk /dev/md2: 489.1 GB, 489095557120 bytes 2 heads, 4 sectors/track, 119408095 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md2 doesn't contain a valid partition table Disk /dev/md1: 524 MB, 524275712 bytes 2 heads, 4 sectors/track, 127997 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md1 doesn't contain a valid partition table # cat /etc/grub.conf default=0 timeout=5 splashimage=(hd2,1)/grub/splash.xpm.gz hiddenmenu title CentOS (2.6.32-220.17.1.el6.x86_64) root (hd2,1) kernel /vmlinuz-2.6.32-220.17.1.el6.x86_64 ro root=UUID=967b4035-782d-4c66-b22f-50244fe970ca rd_MD_UUID=f403a2d0:447803b5:66edba73:569f8305 rd_MD_UUID=a22c43b9:f1954990:d3ddda5e:f9aff3c9 rd_NO_LUKS rd_NO_LVM rd_NO_DM LANG=en_US.UTF-8 SYSFONT=latarcyrheb-sun16 KEYBOARDTYPE=pc KEYTABLE=br-abnt2 crashkernel=auto rhgb quiet initrd /initramfs-2.6.32-220.17.1.el6.x86_64.img

    Read the article

  • Error 22 no such partition on adding a SSD

    - by Clodoaldo
    I'm trying to add a second SSD to a Centos 6 system. But I get the error 22 no such partition at boot. The system already has a single SSD (sdb) and a pair of HDDs (sd{a,c}) in a RAID 1 array from where it boots. It is as if the new SSD assumes one of the devices of the RAID array. Is it? How to avoid that or rearrange the setup? # cat fstab UUID=967b4035-782d-4c66-b22f-50244fe970ca / ext4 defaults 1 1 UUID=86fd06e9-cdc9-4166-ba9f-c237cfc43e02 /boot ext4 defaults 1 2 UUID=72552a7a-d8ae-4f0a-8917-b75a6239ce9f /ssd ext4 discard,relatime 1 2 UUID=8000e5e6-caa2-4765-94f8-9caeb2bda26e swap swap defaults 0 0 tmpfs /dev/shm tmpfs defaults 0 0 devpts /dev/pts devpts gid=5,mode=620 0 0 sysfs /sys sysfs defaults 0 0 proc /proc proc defaults 0 0 # ll /dev/disk/by-id/ total 0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX-part1 -> ../../sdb1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-ST3500413AS_5VMT49E3 -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMT49E3-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 ata-ST3500413AS_5VMTJNAJ-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:0 -> ../../md0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:1 -> ../../md1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-name-localhost.localdomain:2 -> ../../md2 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-a04d7241:8da6023e:f9004352:107a923a -> ../../md1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-a22c43b9:f1954990:d3ddda5e:f9aff3c9 -> ../../md0 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 md-uuid-f403a2d0:447803b5:66edba73:569f8305 -> ../../md2 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_OCZ-VERTEX3_OCZ-43DSRFTNCLE9ZJXX-part1 -> ../../sdb1 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3 -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMT49E3-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 scsi-SATA_ST3500413AS_5VMTJNAJ-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5000c500383621ff -> ../../sdc lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part1 -> ../../sdc1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part2 -> ../../sdc2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c500383621ff-part3 -> ../../sdc3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5000c5003838b2e7 -> ../../sda lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part1 -> ../../sda1 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part2 -> ../../sda2 lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5000c5003838b2e7-part3 -> ../../sda3 lrwxrwxrwx. 1 root root 9 Jun 15 23:50 wwn-0x5e83a97f592139d6 -> ../../sdb lrwxrwxrwx. 1 root root 10 Jun 15 23:50 wwn-0x5e83a97f592139d6-part1 -> ../../sdb1 # fdisk -l Disk /dev/sdb: 120.0 GB, 120034123776 bytes 255 heads, 63 sectors/track, 14593 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x79298ec9 Device Boot Start End Blocks Id System /dev/sdb1 1 14594 117219328 83 Linux Disk /dev/sdc: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000d99de Device Boot Start End Blocks Id System /dev/sdc1 1 1275 10240000 fd Linux raid autodetect /dev/sdc2 * 1275 1339 512000 fd Linux raid autodetect /dev/sdc3 1339 60802 477633536 fd Linux raid autodetect Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x000b3327 Device Boot Start End Blocks Id System /dev/sda1 1 1275 10240000 fd Linux raid autodetect /dev/sda2 * 1275 1339 512000 fd Linux raid autodetect /dev/sda3 1339 60802 477633536 fd Linux raid autodetect Disk /dev/md0: 10.5 GB, 10484641792 bytes 2 heads, 4 sectors/track, 2559727 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table Disk /dev/md2: 489.1 GB, 489095557120 bytes 2 heads, 4 sectors/track, 119408095 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md2 doesn't contain a valid partition table Disk /dev/md1: 524 MB, 524275712 bytes 2 heads, 4 sectors/track, 127997 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md1 doesn't contain a valid partition table # cat /etc/grub.conf default=0 timeout=5 splashimage=(hd2,1)/grub/splash.xpm.gz hiddenmenu title CentOS (2.6.32-220.17.1.el6.x86_64) root (hd2,1) kernel /vmlinuz-2.6.32-220.17.1.el6.x86_64 ro root=UUID=967b4035-782d-4c66-b22f-50244fe970ca rd_MD_UUID=f403a2d0:447803b5:66edba73:569f8305 rd_MD_UUID=a22c43b9:f1954990:d3ddda5e:f9aff3c9 rd_NO_LUKS rd_NO_LVM rd_NO_DM LANG=en_US.UTF-8 SYSFONT=latarcyrheb-sun16 KEYBOARDTYPE=pc KEYTABLE=br-abnt2 crashkernel=auto rhgb quiet initrd /initramfs-2.6.32-220.17.1.el6.x86_64.img

    Read the article

  • T60 Screen/LCD gets black after some minutes with a highpitched sound rising and fading

    - by edelwater
    Just now my T60 screen got "black" (so no display). On my second monitor: no problems so the VGA output works. Symptom: Screen blanks / no display, but it works on the second monitor Steps to reproduce: - boot - wait (it does not matter what you do you do not have to login or anything) - (now the monitor of the laptop slowly begins to make a ssssssssHHHHHHHHHHHHHHHHHWOEOEssssssss noise of about 10 seconds) - right after the sounds ends, the monitor gets black. Sometimes it seems to be the same each time. Software: Installed no new software before/after, running ZoneAlarm and antivirus. Other: It does not feel hot in any place, there don't seem to be running processes with strange behaviour. Warranty: Out of warranty What was I doing: Typing text on a website and doing some PHP coding in a text editor. What can I do here other than buy a new laptop? Does it sound familiar to known cases? Update 1: Exactly the same problem: http://forums.lenovo.com/t5/T61-and-prior-T-series-ThinkPad/T60-Screen-Blackout/m-p/288772 and the second poster (garyj), http://forums.lenovo.com/t5/T61-and-prior-T-series-ThinkPad/Black-Screen-on-T60/m-p/235053#M48627 And here: "I have that same problem. I replaced the CCRL on mine and it works fine when the screen is not screwed in. Once the frame of the LCD screen (metal portion) touches the metal on the laptop which holds the screen the screen goes black. If the metal is touching the screen when you boot up it boots up with it being very dimmly lit. " from http://forums.lenovo.com/t5/T61-and-prior-T-series-ThinkPad/T60-screen-problems/m-p/205047#M44995 (it seems replacing the LCD display is no use, he tried it three times). Same problem: http://forums.lenovo.com/t5/T61-and-prior-T-series-ThinkPad/T60-black-screen/m-p/80604#M25914 Hmmm... not handy 3 or 4 months ago I ordered and installed a new fan. Now the LCD. Which does not seem the core issue but some electric issue so it seems replacing the LCD is not the thing to do here. If it is not the LCD that needs to be replaced (see other threads), which parts can I order to fix this? Is there any information which could lead me to identify the issue? I have read replacing the "inverter" AND the "backlightning" would that make sense? Update 2: I replaced the inverter with another inverter, but IO have the same problem. I DID notice that the inverter is the component that makes the sssssssssssssHHHHHHHHHH sound AND it becomes very hot in a few seconds. (So both the old and the test one) The problem is hmmm wat is then the thing that makes the inverter hot by (assumption) after which it shuts itself down. Is it either the input or the output? The output seems to me not, because the screen seems to function so it must be the electricity coming in. But what causes it to become so hot would it be the VGA card outputting some unusual high voltage seems unlikely? I am looking for the component to order / replace update 3: Great news. Ewendish gave me the hint to look in the BIOS. While I was in the BIOS I noticed that the screen did not switch off and there was not a high pitched sound. So I lowered some settings in the BIOS. I then noticed that with brightness turned to 0 (via FN End), it does not make a high pitched sound and does not turn off, with brightness turned up just three "stripes" it starts making the sound. So I could from now on work under lowest brightness modus or... see where the problem lies. So as stated below with either power management or display drivers / ATI Catalyst settings / Windows display settings. I'm trying to see where it lies, but I will google some first. Update 4: I wiped clean the Windows XP installation and installed Windows 7 on it. Unfortunately the problem remains: as soon as the brightness goes up the screen starts hissing. This means... back to original thought: it probably IS a hardware problem. Although ... again... if it is NOT the inverter, what is it? Could it be the backlightning component? I could try to switch that with a another T60... but this is quite tricky.

    Read the article