Search Results

Search found 36698 results on 1468 pages for 'old linux fan'.

Page 662/1468 | < Previous Page | 658 659 660 661 662 663 664 665 666 667 668 669  | Next Page >

  • Why is my Compaq NC8430 laptop so darned HOT ?

    - by Cheeso
    For a long time I've had a Compaq nc8430 laptop. It's nearly 3 years old now. Originally shipped with WinXP, but I installed Vista on it. From the very start it was not a good experience. This thing has one of those "stickpoint" mice, which I like. After a while, I noticed that the computer was generating lots and lots of heat. So much heat, that the stickpoint bumper would melt and disintegrate. Normally I would expect heat if the CPU was working hard, but even when the CPU was idle, the computer was hot. Much too hot to keep on my lap. Turns out this is not an uncommon problem. I installed the HWmonitor tool, and found that the CPU temp was 82C when it was plugged in - pretty darn hot. And because the temp was so high, the fan never turned off, so the laptop was as loud as a jet engine, always. If I unplugged it from A/C power, the screen would dim and the temperature would decrease, and the fan noise would lessen, but still, it was too loud. It's totally unusable. What is the problem?

    Read the article

  • Migrating mysql 4 to mysql 5

    - by Lennart Regebro
    This seems to me to be a common use case, so I'm surprised so little information is about it, so sorry if it's a duplicate, but I have searched. :) I'm migrating a clients website from one CMS to another, and of moving to newer faster machines all at the same time. As a part of this I'm moving a MySQL database from the old server to the new ones. The problem is that the old server runs MySQL 4 and the new MySQL 5. So when i do a mysqldump at the old site and then try to run it on the new site I get syntax errors. ERROR 1064 (42000) at line 178: You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'BTREE (`id`), KEY `f_ChangedOnWeb` (`f_ChangedOnWeb`), KEY `f_AddressUpdate`' at line 56 I also tried to use an even older syntax by dumping with --compatible mysql323, but that just resulted in ERROR 1062 (23000) at line 2283: Duplicate entry '??????????' for key 2`... It seems to me this must be a reasonably common use case, yet I can't find any sort of help on this. Possibly all my Google searches just drown in irrelevant answers. Most seem to agree that mysqldump is the right answer, but noone mentions that you can get syntax errors...

    Read the article

  • Servers in DMZ will not communicate with each other

    - by Tukaro
    (Full disclosure: I rate barely above "noob" when it comes to networking.) My workplace recent got a new web server. Since we're nearing the end of an overhaul of our website, we're doing a slooooow migration between the old web server and the new one. The old webserver (we'll call it SERVOLD) is Windows Server 2008 with IIS 7. It does not have SQL Server installed. The new server (SERVNEW) is Windows Server 2008 R2, IIS 7.5, with the same version of SQL Server installed. Both are located in the DMZ for our network, and both have their own outward-facing IP address (.3 and .4, respectively). Each server can communicate fine with computers within the domain (not in the DMZ), and those same computers have no trouble communicating with either server. Both servers are also accessible from the internet just fine. However, no matter what, these two servers just refuse to recognize each other. They have the same Workgroup name listed (WORKGROUP), and I thought that would be enough for them to recognize each other. What needs to happen such that I can get these two servers to communicate with each other? We want to do a gradual roll-over to the new website (new one uses ASP.NET, old one uses CFMX), so being able to use one database between both servers is a necessity. Thanks!

    Read the article

  • How to install php-devel under CentOS 6.3 x64?

    - by Jeremy Dicaire
    I'm trying to install php-devel on my CentOS 6.3 VPS and get a failed dependencies test. From phpinfos(): SYSTEM Linux 2.6.32-279.5.2.el6.x86_64 #1 x86_64 NTS error: Failed dependencies: php(x86-64) = 5.4.6-1.el6.remi is needed by php-devel-5.4.6-1.el6.remi.x86_64 I've tried the following RPM packages: php54w-devel-5.4.6-1.w6.x86_64.rpm php-devel-5.4.6-1.el6.remi.i686.rpm php-devel-5.4.6-1.el6.remi.x86_64.rpm One of the above package gave me this: root@sv1 [/tmp]# rpm -Uvh php-devel-5.4.6-1.el6.remi.i686.rpm warning: php-devel-5.4.6-1.el6.remi.i686.rpm: Header V3 DSA/SHA1 Signature, key ID 00f97f56: NOKEY error: Failed dependencies: php(x86-32) = 5.4.6-1.el6.remi is needed by php-devel-5.4.6-1.el6.remi.i686 libbz2.so.1 is needed by php-devel-5.4.6-1.el6.remi.i686 libcom_err.so.2 is needed by php-devel-5.4.6-1.el6.remi.i686 libcrypto.so.10 is needed by php-devel-5.4.6-1.el6.remi.i686 libedit.so.0 is needed by php-devel-5.4.6-1.el6.remi.i686 libgmp.so.3 is needed by php-devel-5.4.6-1.el6.remi.i686 libgssapi_krb5.so.2 is needed by php-devel-5.4.6-1.el6.remi.i686 libk5crypto.so.3 is needed by php-devel-5.4.6-1.el6.remi.i686 libkrb5.so.3 is needed by php-devel-5.4.6-1.el6.remi.i686 libncurses.so.5 is needed by php-devel-5.4.6-1.el6.remi.i686 libssl.so.10 is needed by php-devel-5.4.6-1.el6.remi.i686 libstdc++.so.6 is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2 is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2(LIBXML2_2.4.30) is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2(LIBXML2_2.5.2) is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2(LIBXML2_2.6.0) is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2(LIBXML2_2.6.11) is needed by php-devel-5.4.6-1.el6.remi.i686 libxml2.so.2(LIBXML2_2.6.5) is needed by php-devel-5.4.6-1.el6.remi.i686 libz.so.1 is needed by php-devel-5.4.6-1.el6.remi.i686 I don't know how to fix this error and download all the dependencies. Thank you. Edit 1 (for quanta): Here is "yum repolist": root@sv1 [/tmp]# yum repolist Loaded plugins: fastestmirror, presto Loading mirror speeds from cached hostfile * base: mirror.atlanticmetro.net * epel: mirror.cogentco.com * extras: mirror.atlanticmetro.net * rpmforge: mirror.us.leaseweb.net * updates: centos.mirror.choopa.net repo id repo name status base CentOS-6 - Base 5,980+366 epel Extra Packages for Enterprise Linux 6 - x86_64 6,493+1,272 extras CentOS-6 - Extras 4 rpmforge RHEL 6 - RPMforge.net - dag 2,123+2,310 updates CentOS-6 - Updates 499+29 repolist: 15,099 root@sv1 [/tmp]# rpm -qa | grep php didn't return any result. I forgot to mention I'm using cPanel/WHM Edit 2 after adding the Remi repo: >root@sv1 [/etc/yum.repos.d]# yum clean all Loaded plugins: fastestmirror, presto Cleaning repos: base epel extras remi remi-test rpmforge updates Cleaning up Everything Cleaning up list of fastest mirrors 1 delta-package files removed, by presto >root@sv1 [/etc/yum.repos.d]# yum repolist Loaded plugins: fastestmirror, presto Determining fastest mirrors epel/metalink | 12 kB 00:00 * base: centos.mirror.nac.net * epel: mirror.symnds.com * extras: centos.mirror.choopa.net * remi: remi-mirror.dedipower.com * remi-test: remi-mirror.dedipower.com * rpmforge: mirror.us.leaseweb.net * updates: centos.mirror.nac.net base | 3.7 kB 00:00 base/primary_db | 4.5 MB 00:00 epel | 4.3 kB 00:00 epel/primary_db | 4.7 MB 00:00 extras | 3.0 kB 00:00 extras/primary_db | 6.3 kB 00:00 remi | 2.9 kB 00:00 remi/primary_db | 330 kB 00:00 remi-test | 2.9 kB 00:00 remi-test/primary_db | 85 kB 00:00 rpmforge | 1.9 kB 00:00 rpmforge/primary_db | 2.5 MB 00:00 updates | 3.5 kB 00:00 updates/primary_db | 2.3 MB 00:00 repo id repo name status base CentOS-6 - Base 5,980+366 epel Extra Packages for Enterprise Linux 6 - x86_64 6,493+1,272 extras CentOS-6 - Extras 4 remi Les RPM de remi pour Enterprise Linux 6 - x86_64 96+564 remi-test Les RPM de remi en test pour Enterprise Linux 6 - x86_64 25+139 rpmforge RHEL 6 - RPMforge.net - dag 2,123+2,310 updates CentOS-6 - Updates 499+29 repolist: 15,220 >root@sv1 [/etc/yum.repos.d]# yum install php-devel Loaded plugins: fastestmirror, presto Loading mirror speeds from cached hostfile * base: centos.mirror.nac.net * epel: mirror.symnds.com * extras: centos.mirror.choopa.net * remi: remi-mirror.dedipower.com * remi-test: remi-mirror.dedipower.com * rpmforge: mirror.us.leaseweb.net * updates: centos.mirror.nac.net Setting up Install Process No package php-devel available. Error: Nothing to do >root@sv1 [/etc/yum.repos.d]#

    Read the article

  • What does a DHCP-client consider to be the "best" answer?

    - by Nils
    We have training rooms where normally Windows XP is installed (via PXE). The "normal" DNS/DHCP infrastructure are Windows-Servers. The training room has its own VLAN (different from the Windows servers), so there is most propably an IP helper for DHCP requests active on the Cisco router where all PCs from that room are connected to. Now we wanted to convert some of the PCs to Linux instead. The idea was: Put our own Laptop with a DHCP server into the VLAN of the room and override the "normal" DHCP response. The idea was that this should work, since a directly attached DHCP server in that VLAN should have a faster response-time than the "normal" DHCP server located some hops away from that VLAN. It turned out that this did not work. We had to manually release the lease on the original DHCP server to get it working. On the Laptop we did see the client requesting the IP and "our" dhcp was sending NACKs to the Windows IP request, before that we did offer our own response. Old Question: Why did this not work out as expected? What is making the PC regain its old lease? Update 2012-08-08: The regain-issue has been explained in the DHCP-RFC. Now this explains why the PC regains its old lease. Now we do release the IP from the Windows-DHCP-server before giving it another try. Again - the Windows-DHCP-server wins. I suspect that there is some algorithm for the dhcp-client which determines the "best" dhcp-answer for the client. The new question is: How does the client choose the "best" answer?

    Read the article

  • Cooling for a small server room

    - by John Zwinck
    I have a server room about 12 feet square with an unfinished ceiling (exposed ducts and wiring). It houses a few servers (about ten, 1U and 2U) and some networking gear (four 1U switches, three routers, three modems, two cable boxes). With the door closed, it runs around 80 degrees Fahrenheit with half the servers turned on. When I turned on all the servers it reached 86 before I chickened out and propped the door open. The room is adjacent to air-conditioned office space, but does not itself have dedicated air conditioning. The ventilation for this room seems to be limited to one duct coming in at ceiling level, with a powered fan to draw air in, and one duct at ceiling level to allow air to flow out (it seems like it may just go into the drop ceiling cavity in the adjacent room). The adjacent office space stays fairly cool, but I'd prefer not to leave the door propped open all the time. There is both 110v and 208v service in the room, and plenty of power available. But there are no windows, and no floor drains (in a pinch we might be able to run a condensation hose through a small hole we'd drill in the wall to a nearby sink area, but only if absolutely necessary). I've considered portable A/C units, but I'm not sure on sizing and a lot less sure how we would run the exhaust hose(s). I suppose we could point one at the existing room exhaust duct (air return), but substantially modifying the duct is probably a no-no. I've also considered installing a fan box in the door of the room, but I'm concerned that this will only drop the temperature a little. Even right now, with all the equipment on, the room is at 83 degrees with the door open. And the main building A/C turns off daily at 6 PM to conserve energy, so the adjacent room temperature rises at night. How would you cool this room? Let's say the goal is to bring the temperature with everything running from a steady state of around 90 degrees down to 75 (equivalently, to offset the heat produced by ten 1U servers).

    Read the article

  • What is the fastest and best way to convert an rmvb video to mp4/mkv without losing any quality?

    - by Eric Leung
    the file will be played in a popbox3d. my old method was to convert the video using vidcoder (an offshoot of handbrake) using normal settings, but i've recently confirmed that this significantly reduces video and audio quality. i bumped up the conversion quality to 'high profile' and this produced a higher quality video but raised the conversion time to about twice the video length (95 minutes to convert a 45 minute video) on a core2duo laptop. this is less than ideal when a large number of videos need to be converted. i have tried a direct remuxing using mkv toolnix but this produced a video that refused to display video on the popbox3d, which is consistent with the reported: [quote=other old thread] it is possible to put RealMedia A/V in MKV container (used MKVtoolnix) - however, it is awkward to play later. RV40 is only suspected to be based on H.264 - simplify, is not consistent with MPEG-4 AVC specification. [/quote] i have read that ... [quote=from old thread] Under normal circumstances, [ffmpeg] should convert the video to .video.mp4 and the audio to (.wav then to) .audio.mp4, then mux the video and audio into a new .mp4 file and delete the temporary video-only and audio-only files.[/quote] and i am currently attempting to discover how this is done. help? PS: i download a lot of series from asia and for some strange reason, rmvb is a really popular format over there. sometimes, it's the only format that's available. unfortunately, it's a format that is incompatible with the popbox3d, so i have to convert the files before i can watch them on my tv.

    Read the article

  • Need to Remove Exchange 2003 Server That Crashed During Transition to 2010

    - by ThaKidd
    As the title stated, we were running an Exchange 2003 server that we knew was going down soon so we purchased a second server and installed Exchange 2010 into the AD. We managed to move all of the mailboxes off of 2003 and also managed to get the Offline Address Book setup on 2010. At this point the 2003 server bit the dust and will no longer boot. Therefore we were unable to properly uninstall Exchange and remove the last 2003 server so it still exists in AD. As far as the clients are concerned, everything is working properly. However, when I run the Microsoft Exchange Profile Analyzer, I still see the old server and its Administrative Group. I am going to guess that since the old server is showing up in AD, I will not be able to raise Exchange or AD functionality (as the 2003 server was also the only AD DC) levels. I have forced the 2003 DC out of AD so that is no longer an issue. Old Setup: Windows 2003 Server Enterprise & Exchange 2003 Standard New Setup: Windows 2010 Server Enterprise & Exchange 2010 Standard Two Questions: How do you go about manually forcing the 2003 server and its administrative group out of AD? When that is finished, where do you raise the Exchange mode (can't find this for the life of me)?

    Read the article

  • Does AMD Cool n Quiet Slow Down Your System?

    - by Software Monkey
    I discovered today that having AMD Cool n Quiet enabled in my BIOS appears to be slowing down my Windows XP SP2 system by about 29% on memory & CPU intensive workloads. I was wondering if (a) anyone else had encountered this, (b) anyone can offer an explanation, (c) there are any negatives I need to be aware of if I keep AMD CnQ disabled. With some superficial testing so far, I don't immediately notice any difference with CnQ off (other than the performance being what I expected from this new hardware). It seems to ramp up the CPU fan a little bit as my program maxes out 1 core, but that's the same as with CnQ on. And when I let the system idle the CPU fan slows down and the systems as quiet as a mouse (after years of 6 small fans churning like they want to go into orbit it's nice to again have a system where I can hear the HDDs seeking). Bonus question: Does CnQ cause issues with system stability? I ask because the reason I disabled it was because I have had a few freezes and 1 spontaneous reboot with my new hardware.

    Read the article

  • Migrateing to Windows Server 2008 R2 Domain Controllers - a few Questions/Issues

    - by Chris
    Ok so here's our setup: We have 2 Windows2k3 Domain Controllers. I am trying to replace them with Windows 2008 R2. The Win2k3 servers are DC01 and DC02. The Windows2k8 servers are DC1 and DC2. I prepared the Windows Server 2003 Forest Schema for a Domain Controller That Runs Windows Server 2008 or Windows Server 2008 R2. Then with both of the new servers up as member servers I dcpromo'd DC1 using the advanced option and added it successfully to my exisiting domain. Roles are GC, DNS and Active Directory Domain Services.I transferred The PDC, RID pool manager and Infrastructure master FSMO to the new DC.(DC1) The Schema master and Domain naming master are still on the old DC (DC01). The first issue I'm encountering is when i dcpromo the second DC (DC2) and select "Replicate data over the network from and existing domain controller" I select the new DC to replicate from (DC1) I get the following error: "Failed to identify the requested replica partner (dc1.xxx.org) as a valid domain controller with a machine account for (DC2$). This is likely due to either the machine account not being replicated to this domain controller because of replication latency or the domain controller not advertising the Active Directory Domain Services. Please consider retrying the operation with \dc01.xxx.org as the replica partner. "The server is unwilling to process the request." Is this because the Schema master and Domain naming master roles are still on the old DC (DC01)? And if so, if I transfer Schema master and Domain naming master roles to DC1 what is the risk or breaking my AD? I'm a little paranoid because this process HAS to be transparent. ANY down time or interruption will result in me getting a verbal ass kicking from my I.T. Director. Both of the new servers DNS point the the old DNS servers (DC01 and DC02) not themselves by the way. Thanks in Advance -Chris

    Read the article

  • no mails routed to/from new Exchange 2010

    - by Michael
    I have an Exchange Server 2003 up and running for years. Now I am in the mid of transition to Exchange Server 2010, I already installed it, put the latest Servicepack on it and everything seems fine, BUT: Mails do not get delivered to MailBoxes on the new Exchange 2010. e.g. when I create a new mailbox on the old server, Emails in and out to/from it work like a charm. But as soon as I move it to the new server, emails get stuck. Noe delivered from outside or old mailboxes, not send out from the new server to enywhere. Sending between Mailboxes on the new Server of course is working. I can see the connectors between old and new Server in the Exchange 2003 Admin Tool, but I cannot find these nowhere on the new server. I have also setup sending connectors at the new server to send out mails directly, but that does not work. In all other areas, the servers are perfectly working together - moving mailboxes between, seeing each other etc. "just" they dont exchange (!) any emails - Any ideas what I missed? I also followed the hints from: Upgrading from Exchange 2003 to Exchange 2010, routing works in one direction only There Emails were transported at least in one direction, in my case they are not transported at all. Both my connectors are up and valid abd have the correct source/target shown on Get-RoutingGroupConnector | FL Kind regards Michael

    Read the article

  • IIS ASP Redirect Removal

    - by Kim L
    We have a website that is setup on IIS 7 and are trying to replace it with a new site, but need a redirect that is in place removed. The old site used a custom file as the homepage (WN-main.asp). We removed all the old site files, including web.config, and placed them in a subdirectory for safe keeping. The new site no longer uses ASP, and we'd like to use a regular index.html as the default. However, when we go to the website, it keeps trying to redirect our .com to .com/WN-main.asp -- and that gives us a 404 Error in the Application for "Default Web Site" because we removed that page. In the IIS "Default Document" settings we have index.html at the top, and WN-main.asp is nowhere to be found in the list (it never was there). We've also removed the web.config file from the root directory, and put the entire old website in a subdirectory. As well as restarted IIS. We're assuming that the redirect is setup somewhere in IIS because if I navigate to .com/index.html which is our new site, it works. Our problem is that oursite.com redirects to oursite.com/WN-main.asp. Grr. If you go to www.worzalla.com you can see how it redirects to the WN-main.asp page right now as the homepage. Any ideas where this redirect could have been setup so we can remove it? Thanks!

    Read the article

  • How to copy mailboxes from Exchange 2003 to Exchange 2007 across forests?

    - by Tor Ivar Larsen
    Hi. Were going through a quite difficult conversion from an old ASP-solution to an entirely new one. This includes moving mailboxes from Ex2003 to Ex2007. We want to do this without deleting the old mailboxes on the Ex2003 server, to have a "fall back" in case somehing goes wrong. I have investigated the "Move-Mailbox" cmdlet in the Ex2007 shell, and it seems to fit our needs quite well. The only problem being that we want to keep the old mailboxes. This could easily be accomplished with the -SourceMailboxCleanupOptions, but we can't use this when we have used the -AllowMerge switch. The reason we need -AllowMerge is because all the user accounts with connected mailboxes are already created on Ex2007(Some automatic user creation tool, no real relevance to the case in question) The twist is that the exchange servers are in two different forests... Windows 2003 SP1 on DC1, Windows 2003 SP2 on DC2 in forest 1. Windows 2003 R2 SP2 on DC1 in forest 2. Can we use the Move-Mailbox safely for this purpose? And if yes, how?

    Read the article

  • Is this processor burned?

    - by Jhonnytunes
    I've recently exchange the processors in two PCChips boards. Both boards are LGA775. Board A is P17G(Pentium 4 HyperThreading 3GHz) and board B is P49G(Pentium Dual Core 3GHz). I use board A to watch videos, and some of them are 3GB size and this is why I exchanged the CPU. I installed Dual Core in board A and it worked out of the box, now 3GB videos use 5% of CPU instead of 50%. When I installed the pentium in the board B, I forgot to connect the 4pin power and, when i powered on the PC, the CPU fan stay off. Then, I connected all right this time, and now the board doesnt show video. I think the CPU is not working but im not sure about that. The PC turns on and the HD spins, the CPU fan spins, network socket blinking, but not video and case power led is neither blinking. I tried with other PSU and everything was the same. I figure out that CPU have that paste above. IDK really what's happening, I hope I dont have to buy another CPU. Is it Burned?

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • What options to use for Accurate bacula backup?

    - by Kiss Stefan
    It's actually 2 question in one. First is a bit more theoretically. So when specifying accurate options how does bacula figure out if a file needs to be backed up ? it's a simple AND ? As in if the options are Accurate = sm5 bacula will not backup the file if ((size = old size) AND (modtime = old modtime) AND (md5 = old md5)) Is that correct ? Do any of the options take precedence ? as in would be a file skipped if modif time is diffreent but it has the same md5sum ? Are there any implied options that you cannot ignore ? Practical case, ( bacula 5.0.1 ) I have to back-up a svn repo, in order to be able to make incremental backups as simple as posible i am hotcopying (client run before) it to another location, that bacula will backup ( then delete it with client run after). Now in the fileset i have Accurate = spnd5 This should tell bacula to take into consideration size , permission bits number of links , decreases in size and md5sum. However , an incremental is also including a full copy of the svn. What am i doing wrong ? it seems that it takes into account creation time even tho i have not specified it.

    Read the article

  • Can I recover a zpool after it's been exported, given that devices have not been reallocated?

    - by cali-spc
    I had a zpool we'll call 'testpool'. testpool had 3 devices included in it, and a single zfs called 'test'. I needed to move 'test' to a new, smaller pool. I wanted to name the new pool the same name 'testpool'. Basically did the following. zfs send testpool@backup > /tmp/test-dump zpool export -f testpool zpool create -f testpool newdevice zfs receive -F testpool < /tmp/test-dump Unfortunately I found out that the testpool@backup snapshot was the wrong snapshot. Too old. I have yet to reallocate the three devices that were in the OLD testpool. (None of these 3 devices are 'newdevice', they are a separate 3.) Is there any way I can recover data in those devices? I'm thinking since I named the new, smaller pool the same as the old zpool, I'm pretty much SOL. But if not, that would be nice to know. Edit: More info I did a 'zpool import' and got this. bash-3.00# zpool import pool: testpool id: 14781458723915654709 state: ONLINE action: The pool can be imported using its name or numeric identifier. config: testpool ONLINE c5t8d0 ONLINE c5t9d0 ONLINE c5t10d0 ONLINE So I'm guessing I just need the syntax to import this zpool using its numeric identifier, while giving it a new name. S.

    Read the article

  • Can't re-mount existing RAID10 on Ubuntu

    - by Zoran
    I saw similar questions, but didn't find what solution to my problem. After power-cut, one of RAID10 (4 disks were) appears to be malfunctioning. I make tha array active one, but can not mount it. Always the same error: mount: you must specify the filesystem type So, here is what I have when type mdadm --detail /dev/md0 /dev/md0: Version : 00.90.03 Creation Time : Tue Sep 1 11:00:40 2009 Raid Level : raid10 Array Size : 1465148928 (1397.27 GiB 1500.31 GB) Used Dev Size : 732574464 (698.64 GiB 750.16 GB) Raid Devices : 4 Total Devices : 3 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Mon Jun 11 09:54:27 2012 State : clean, degraded Active Devices : 3 Working Devices : 3 Failed Devices : 0 Spare Devices : 0 Layout : near=2, far=1 Chunk Size : 64K UUID : 1a02e789:c34377a1:2e29483d:f114274d Events : 0.166 Number Major Minor RaidDevice State 0 8 16 0 active sync /dev/sdb 1 0 0 1 removed 2 8 48 2 active sync /dev/sdd 3 8 64 3 active sync /dev/sde At the /etc/mdadm/mdadm.conf I have by default, scan all partitions (/proc/partitions) for MD superblocks. alternatively, specify devices to scan, using wildcards if desired. DEVICE partitions auto-create devices with Debian standard permissions CREATE owner=root group=disk mode=0660 auto=yes automatically tag new arrays as belonging to the local system HOMEHOST <system> instruct the monitoring daemon where to send mail alerts MAILADDR root definitions of existing MD arrays ARRAY /dev/md0 level=raid10 num-devices=4 UUID=1a02e789:c34377a1:2e29483d:f114274d ARRAY /dev/md1 level=raid1 num-devices=2 UUID=9b592be7:c6a2052f:2e29483d:f114274d This file was auto-generated... So, my question is, how can I mount md0 array (md1 has been mounted without problem) in order to preserve existing data? One more thing, fdisk -l command gives the following result: Disk /dev/sdb: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x660a6799 Device Boot Start End Blocks Id System /dev/sdb1 * 1 88217 708603021 83 Linux /dev/sdb2 88218 91201 23968980 5 Extended /dev/sdb5 88218 91201 23968948+ 82 Linux swap / Solaris Disk /dev/sdc: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x0008f8ae Device Boot Start End Blocks Id System /dev/sdc1 1 88217 708603021 83 Linux /dev/sdc2 88218 91201 23968980 5 Extended /dev/sdc5 88218 91201 23968948+ 82 Linux swap / Solaris Disk /dev/sdd: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x4be1abdb Device Boot Start End Blocks Id System Disk /dev/sde: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xa4d5632e Device Boot Start End Blocks Id System Disk /dev/sdf: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Disk /dev/sdg: 750.1 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Disk /dev/md1: 750.1 GB, 750156251136 bytes 2 heads, 4 sectors/track, 183143616 cylinders Units = cylinders of 8 * 512 = 4096 bytes Disk identifier: 0xdacb141c Device Boot Start End Blocks Id System Warning: ignoring extra data in partition table 5 Warning: ignoring extra data in partition table 5 Warning: ignoring extra data in partition table 5 Warning: invalid flag 0x7b6e of partition table 5 will be corrected by w(rite) Disk /dev/md0: 1500.3 GB, 1500312502272 bytes 255 heads, 63 sectors/track, 182402 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x660a6799 Device Boot Start End Blocks Id System /dev/md0p1 * 1 88217 708603021 83 Linux /dev/md0p2 88218 91201 23968980 5 Extended /dev/md0p5 ? 121767 155317 269488144 20 Unknown And one more thing. When using mdadm --examine command, here ise result: mdadm -v --examine --scan /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sd ARRAY /dev/md1 level=raid1 num-devices=2 UUID=9b592be7:c6a2052f:2e29483d:f114274d devices=/dev/sdf ARRAY /dev/md0 level=raid10 num-devices=4 UUID=1a02e789:c34377a1:2e29483d:f114274d devices=/dev/sdb,/dev/sdc,/dev/sdd,/dev/sde md0 has 3 devices which are active. Can someone instruct me how to solve this issue? If it is possible, I would like not to removing faulty HDD. Please advise

    Read the article

  • What can I do to prevent system power downs?

    - by Joe King
    Yesterday I was given my brother's old laptop - core i7, 2.67GHz, 8GB RAM, 128GB SSD, Win7 64 bit. It's a Sony Vaio Z11. Approx 18 months old. When running something computationally intensive, the fan starts up and after about 30 secs it just powers itself down with no warning. I guess it is overheating. There is nothing in the event logs to suggest what is causing it - the only thing I see is "the last system shutdown was unexpected" or something similar. This is a problem for me because I use a lot of number crunching apps, which pretty much makes it useless to me. I would like to know if there is anything I can do, other than the obvious things I've done already - open up and clean out dust, re-install the OS. According to my brother, this problem started about 6 months ago when it was already outside warranty. If it's just used for simple things - web browsing, word processing etc, the problem does not occur. Any ideas for what I can do to fix this ? Update: I found that the laptop has 2 hardware settings for graphics: Speed and Stamina - the Speed setting seems to use an nvidia GEforce GT 330M, while the Stamina setting uses an Intel chipset. With the setting on Speed, I can hear the fan the whole time, and the system powers down after a short while (5-10 mins) even just doing basic tasks (browsing this site for example), but doesn't shut down if I just leave it switched on. In this mode it also sometimes just freezes the screen and I have to power off myself. However on Stamina setting it only powers down when doing number crunching and never freezes the screen.

    Read the article

  • Unicorn installation error on Debian 5

    - by Luc
    I am running ruby1.9 on Debian 5, and did not manage to install 'unicorn' with rubygems. I got this error and do not really know how to solve it. Do you have any idea of the possible root cause ? > gem install unicorn Building native extensions. This could take a while... ERROR: Error installing unicorn: ERROR: Failed to build gem native extension. /usr/bin/ruby1.9 extconf.rb checking for CLOCK_MONOTONIC in time.h... yes checking for clockid_t in time.h... yes checking for clock_gettime() in -lrt... yes checking for t_open() in -lnsl... no checking for socket() in -lsocket... no checking for poll() in poll.h... yes checking for getaddrinfo() in sys/types.h,sys/socket.h,netdb.h... yes checking for getnameinfo() in sys/types.h,sys/socket.h,netdb.h... yes checking for struct sockaddr_storage in sys/types.h,sys/socket.h... yes checking for accept4() in sys/socket.h... no checking for sys/select.h... yes checking for ruby/io.h... yes checking for rb_io_t.fd in ruby.h,ruby/io.h... yes checking for rb_io_t.mode in ruby.h,ruby/io.h... yes checking for rb_io_t.pathv in ruby.h,ruby/io.h... no checking for struct RFile in ruby.h,ruby/io.h... yes checking size of struct RFile in ruby.h,ruby/io.h... 24 checking for struct RObject... no checking size of int... 4 checking for rb_io_ascii8bit_binmode()... no checking for rb_thread_blocking_region()... yes checking for rb_thread_io_blocking_region()... no checking for rb_str_set_len()... yes checking for rb_time_interval()... yes checking for rb_wait_for_single_fd()... no creating Makefile make cc -I. -I/usr/include/ruby-1.9.0/x86_64-linux -I/usr/include/ruby-1.9.0 -I. -DHAVE_TYPE_CLOCKID_T -DHAVE_POLL -DHAVE_GETADDRINFO -DHAVE_GETNAMEINFO -DHAVE_TYPE_STRUCT_SOCKADDR_STORAGE -DHAVE_SYS_SELECT_H -DHAVE_RUBY_IO_H -DHAVE_RB_IO_T_FD -DHAVE_ST_FD -DHAVE_RB_IO_T_MODE -DHAVE_ST_MODE -DHAVE_TYPE_STRUCT_RFILE -DSIZEOF_STRUCT_RFILE=24 -DSIZEOF_INT=4 -DHAVE_RB_THREAD_BLOCKING_REGION -DHAVE_RB_STR_SET_LEN -DHAVE_RB_TIME_INTERVAL -D_GNU_SOURCE -DPOSIX_C_SOURCE=1-D_POSIX_C_SOURCE=200112L -fPIC -fno-strict-aliasing -g -g -O2 -O2 -g -Wall -Wno-parentheses -fPIC -o kgio_ext.o -c kgio_ext.c cc -I. -I/usr/include/ruby-1.9.0/x86_64-linux -I/usr/include/ruby-1.9.0 -I. -DHAVE_TYPE_CLOCKID_T -DHAVE_POLL -DHAVE_GETADDRINFO -DHAVE_GETNAMEINFO -DHAVE_TYPE_STRUCT_SOCKADDR_STORAGE -DHAVE_SYS_SELECT_H -DHAVE_RUBY_IO_H -DHAVE_RB_IO_T_FD -DHAVE_ST_FD -DHAVE_RB_IO_T_MODE -DHAVE_ST_MODE -DHAVE_TYPE_STRUCT_RFILE -DSIZEOF_STRUCT_RFILE=24 -DSIZEOF_INT=4 -DHAVE_RB_THREAD_BLOCKING_REGION -DHAVE_RB_STR_SET_LEN -DHAVE_RB_TIME_INTERVAL -D_GNU_SOURCE -DPOSIX_C_SOURCE=1-D_POSIX_C_SOURCE=200112L -fPIC -fno-strict-aliasing -g -g -O2 -O2 -g -Wall -Wno-parentheses -fPIC -o autopush.o -c autopush.c cc -I. -I/usr/include/ruby-1.9.0/x86_64-linux -I/usr/include/ruby-1.9.0 -I. -DHAVE_TYPE_CLOCKID_T -DHAVE_POLL -DHAVE_GETADDRINFO -DHAVE_GETNAMEINFO -DHAVE_TYPE_STRUCT_SOCKADDR_STORAGE -DHAVE_SYS_SELECT_H -DHAVE_RUBY_IO_H -DHAVE_RB_IO_T_FD -DHAVE_ST_FD -DHAVE_RB_IO_T_MODE -DHAVE_ST_MODE -DHAVE_TYPE_STRUCT_RFILE -DSIZEOF_STRUCT_RFILE=24 -DSIZEOF_INT=4 -DHAVE_RB_THREAD_BLOCKING_REGION -DHAVE_RB_STR_SET_LEN -DHAVE_RB_TIME_INTERVAL -D_GNU_SOURCE -DPOSIX_C_SOURCE=1-D_POSIX_C_SOURCE=200112L -fPIC -fno-strict-aliasing -g -g -O2 -O2 -g -Wall -Wno-parentheses -fPIC -o wait.o -c wait.c cc -I. -I/usr/include/ruby-1.9.0/x86_64-linux -I/usr/include/ruby-1.9.0 -I. -DHAVE_TYPE_CLOCKID_T -DHAVE_POLL -DHAVE_GETADDRINFO -DHAVE_GETNAMEINFO -DHAVE_TYPE_STRUCT_SOCKADDR_STORAGE -DHAVE_SYS_SELECT_H -DHAVE_RUBY_IO_H -DHAVE_RB_IO_T_FD -DHAVE_ST_FD -DHAVE_RB_IO_T_MODE -DHAVE_ST_MODE -DHAVE_TYPE_STRUCT_RFILE -DSIZEOF_STRUCT_RFILE=24 -DSIZEOF_INT=4 -DHAVE_RB_THREAD_BLOCKING_REGION -DHAVE_RB_STR_SET_LEN -DHAVE_RB_TIME_INTERVAL -D_GNU_SOURCE -DPOSIX_C_SOURCE=1-D_POSIX_C_SOURCE=200112L -fPIC -fno-strict-aliasing -g -g -O2 -O2 -g -Wall -Wno-parentheses -fPIC -o connect.o -c connect.c cc -I. -I/usr/include/ruby-1.9.0/x86_64-linux -I/usr/include/ruby-1.9.0 -I. -DHAVE_TYPE_CLOCKID_T -DHAVE_POLL -DHAVE_GETADDRINFO -DHAVE_GETNAMEINFO -DHAVE_TYPE_STRUCT_SOCKADDR_STORAGE -DHAVE_SYS_SELECT_H -DHAVE_RUBY_IO_H -DHAVE_RB_IO_T_FD -DHAVE_ST_FD -DHAVE_RB_IO_T_MODE -DHAVE_ST_MODE -DHAVE_TYPE_STRUCT_RFILE -DSIZEOF_STRUCT_RFILE=24 -DSIZEOF_INT=4 -DHAVE_RB_THREAD_BLOCKING_REGION -DHAVE_RB_STR_SET_LEN -DHAVE_RB_TIME_INTERVAL -D_GNU_SOURCE -DPOSIX_C_SOURCE=1-D_POSIX_C_SOURCE=200112L -fPIC -fno-strict-aliasing -g -g -O2 -O2 -g -Wall -Wno-parentheses -fPIC -o poll.o -c poll.c poll.c:11:18: error: st.h: No such file or directory poll.c: In function 'do_poll': poll.c:148: error: 'RUBY_UBF_IO' undeclared (first use in this function) poll.c:148: error: (Each undeclared identifier is reported only once poll.c:148: error: for each function it appears in.) make: *** [poll.o] Error 1 Gem files will remain installed in /usr/lib/ruby/gems/1.9.0/gems/kgio-2.5.0 for inspection. Results logged to /usr/lib/ruby/gems/1.9.0/gems/kgio-2.5.0/ext/kgio/gem_make.out

    Read the article

  • Can't seem to get chassis fans running

    - by TK Kocheran
    I've got a ASUS ROG Maximus V Extreme and I'm trying to connect my fans to the chassis fan pins to get them running according to the motherboard. I know for sure that my fans work, as when I test them with my Molex connector, they all happily power on. Here's two of my chassis fans connectors (there are 3-4): Here's the connector that came with either my motherboard or the PSU, can't remember :) I've never seen one of these strange cables before. All I know is that if I plug in the 4-pin mobo connector to either of these fan plugs, fans don't come on and don't show up in the BIOS. (Motherboard has a crazy awesome UEFI BIOS and shows you if it sees the fans.) If I try plugging the 4-pin connection into the mobo and the other side into the PSU, I can't POST. If I plug the PSU connector in without the mobo connector, fans come on. What could I be doing wrong here? Is it a problem with the cable I'm using? Is there something I may have missed in the build?

    Read the article

  • Can I get all active directory passwords in clear text using reversible encryption?

    - by christian123
    EDIT: Can anybody actually answer the question? Thanks, I don't need no audit trail, I WILL know all the passwords and users can't change them and I will continue to do so. This is not for hacking! We recently migrated away from a old and rusty Linux/Samba domain to an active directory. We had a custom little interface to manage accounts there. It always stored the passwords of all users and all service accounts in cleartext in a secure location (Of course, many of you will certainly not think of this a being secure, but without real exploits nobody could read that) and disabled password changing on the samba domain controller. In addition, no user can ever select his own passwords, we create them using pwgen. We don't change them every 40 days or so, but only every 2 years to reward employees for really learning them and NOT writing them down. We need the passwords to e.g. go into user accounts and modify settings that are too complicated for group policies or to help users. These might certainly be controversial policies, but I want to continue them on AD. Now I save new accounts and their PWGEN-generated (pwgen creates nice sounding random words with nice amounts of vowels, consonants and numbers) manually into the old text-file that the old scripts used to maintain automatically. How can I get this functionality back in AD? I see that there is "reversible encryption" in AD accounts, probably for challenge response authentication systems that need the cleartext password stored on the server. Is there a script that displays all these passwords? That would be great. (Again: I trust my DC not to be compromised.) Or can I have a plugin into AD users&computers that gets a notification of every new password and stores it into a file? On clients that is possible with GINA-dlls, they can get notified about passwords and get the cleartext.

    Read the article

  • Windows 7 boot problem on a Lenovo Thinkpad Z61m 9450HAG

    - by Matt Taylor
    I recently did a full upgrade of Windows 7 on my Thinkpad. Everything worked fine after up until the second reboot (the first reboot after some updates installed worked OK). At second reboot time the system would just black screen before the Windows logo appears. Disk/wireless/power/battery lights are all lit and the disk light is active (flickering). However, if I remove my battery and boot with just power it boots fine and quickly, and everything is OK. Any help on why this won't boot with battery plugged in is greatly appreciated. I need to take this battery out on the road/trains, etc. A little more detail on this story. The battery I had inserted when doing the (failed) boot was a long life battery. I have not tried inserting this battery when Windows is logged in. I have another (normal life) battery that I have charged up within Windows. It has just got to 100% and I am about to reboot with it in. I am using the Lenovo power manager to diagnose the battery - all seems OK. I will report back shortly as to the outcome. OK, so I chose the reboot option from within Windows, the machine seemed to shutdown okay, but then stalled. It didn't turn off completely and didn't reboot, but just sat, with the fan humming, somewhere in between! I had to hold the power button in for a few seconds until the fan stopped and then hit the power button again to boot the machine from fresh. One good thing, with this battery (the normal one) it booted into Windows 7 the first time with a battery! So, now I have rebooting issues. I have 3 errors in the event log: A timeout was reached (30000 milliseconds) while waiting for the lxdxCATSCustConnectService service to connect. The lxdxCATSCustConnectService service failed to start due to the following error: The service did not respond to the start or control request in a timely fashion. The following boot-start or system-start driver(s) failed to load: cdrom Any thoughts?

    Read the article

  • Compaq motherboard CQ60 AMD - nvidia chipsed graphic problem

    - by Dritan
    Hi! It nice to have read that you solved this problem this way. I have 2 laptops Compaq CQ60 AMD Athlon with Nvidia graphic cards. the first one is new, when i press power button, it lights up only the ON led in front and nothing else, no fan working, blank screen, no beep.. I don't know what may be the problem. When I put on power adaptor, it lights up only the side power led near dhe power adapter plug but it doesn't light up the front led one. the second one have this problem that it spins the fan, light power and On led, but it doesn't show nothing on the screen blank (even with external monitor). In this case it maybe this problem of the Nvida Graphic Chip and it may need a reflow. I have an hot air station, but I don't know if I should try this or the oven one. Please can you give me any suggestion what to do to solve this. I have read that the solution of the Oven method is just temporary,maximum of three months, do you have the same experience about this? Any suggestion is wellcome.

    Read the article

  • How to create a init.d script for openssh-server which was compiled and installed from source using configure + make + make install?

    - by Patrick L
    I have installed openssh-server in my Ubuntu PC using apt-get install openssh-server. The version is 5.9. Now, I would like to compile and install openssh-server version 6.2 from source codes. I have successfully downloaded the source codes, and run the following commands: ./configure make make install I found that the new version of openssh-server was installed into /usr/local/sbin/. The old version of openssh-server is in /usr/sbin/. I found that the service script in /etc/init.d/ssh is still pointing to /usr/sbin/. And the old openssh-server (v5.9) is still running. How can I replace the old openssh-server with the new openssh-server that I have just compiled and installed? How can I create a init.d script to start and stop the new openssh-server that I've compiled from source manually? How to start the new openssh-server on boot? When I install openssh-server using apt-get install, the config files will be installed into /etc/ssh/. If I compile and install it from source, where is the config file? If I compiled openssh-server from source, but I install openssh-client package using apt-get install, will there be any config files conflict? Thanks.

    Read the article

< Previous Page | 658 659 660 661 662 663 664 665 666 667 668 669  | Next Page >