  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Windows Server 2008 R2 network adapter stops working, requires hard reboot

    - by Geoff Dalgas
    TL;DR version: Turns out this was a Windows Server 2008 R2 kernel networking bug. After siccing Microsoft support on it, we (eventually) got an unpublished kernel hotfix from Microsoft to address it. If you, too, are experiencing mysterious low-level network driver failures requiring a reboot/bluescreen cycle, you might want that hotfix (or maybe Service Pack 1 whenever it is released, too.) We have been using HAProxy along with heartbeat from the Linux-HA project. We are using two linux instances to provide a failover. Each server has with their own public IP and a single IP which is shared between the two using a virtual interface (eth1:1) at IP: 69.59.196.211 The virtual interface (eth1:1) IP 69.59.196.211 is configured as the gateway for the windows servers behind them and we use ip_forwarding to route traffic. We are experiencing an occasional network outage on one of our windows servers behind our linux gateways. HAProxy will detect the server is offline which we can verify by remoting to the failed server and attempting to ping the gateway: Pinging 69.59.196.211 with 32 bytes of data: Reply from 69.59.196.220: Destination host unreachable. Running arp -a on this failed server shows that there is no entry for the gateway address (69.59.196.211): Interface: 69.59.196.220 --- 0xa Internet Address Physical Address Type 69.59.196.161 00-26-88-63-c7-80 dynamic 69.59.196.210 00-15-5d-0a-3e-0e dynamic 69.59.196.212 00-21-5e-4d-45-c9 dynamic 69.59.196.213 00-15-5d-00-b2-0d dynamic 69.59.196.215 00-21-5e-4d-61-1a dynamic 69.59.196.217 00-21-5e-4d-2c-e8 dynamic 69.59.196.219 00-21-5e-4d-38-e5 dynamic 69.59.196.221 00-15-5d-00-b2-0d dynamic 69.59.196.222 00-15-5d-0a-3e-09 dynamic 69.59.196.223 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 225.0.0.1 01-00-5e-00-00-01 static On our linux gateway instances arp -a shows: peak-colo-196-220.peak.org (69.59.196.220) at <incomplete> on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-222.peak.org (69.59.196.222) at 00:15:5d:0a:3e:09 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 Why would arp occasionally set the entry for this failed server as <incomplete>? Should we be defining our arp entries statically? I've always left arp alone since it works 99% of the time, but in this one instance it appears to be failing. Are there any additional troubleshooting steps we can take help resolve this issue? THINGS WE HAVE TRIED I added a static arp entry for testing on one of the linux gateways which still didn't help. root@haproxy2:~# arp -a peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-221.peak.org (69.59.196.221) at 00:15:5d:00:b2:0d [ether] on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 peak-colo-196-220.peak.org (69.59.196.220) at 00:21:5e:4d:30:8d [ether] PERM on eth1 root@haproxy2:~# arp -i eth1 -s 69.59.196.220 00:21:5e:4d:30:8d root@haproxy2:~# ping 69.59.196.220 PING 69.59.196.220 (69.59.196.220) 56(84) bytes of data. --- 69.59.196.220 ping statistics --- 7 packets transmitted, 0 received, 100% packet loss, time 6006ms Rebooting the windows web server solves this issue temporarily with no other changes to the network but our experience shows this issue will come back. Swapping network cards and switches I noticed the link light on the port of the switch for the failed windows server was running at 100Mb instead of 1Gb on the failed interface. I moved the cable to several other open ports and the link indicated 100Mb for each port that I tried. I also swapped the cable with the same result. I tried changing the properties of the network card in windows and the server locked up and required a hard reset after clicking apply. This windows server has two physical network interfaces so I have swapped the cables and network settings on the two interfaces to see if the problem follows the interface. If the public interface goes down again we will know that it is not an issue with the network card. (We also tried another switch we have on hand, no change) Changing network hardware driver versions We've had the same problem with the latest Broadcom driver, as well as the built-in driver that ships in Windows Server 2008 R2. Replacing network cables As a last ditch effort we remembered another change that occurred was the replacement of all of the patch cords between our servers / switch. We had purchased two sets, one green of lengths 1ft - 3ft for the private interfaces and another set of red cables for the public interfaces. We swapped out all of the public interface patch cables with a different brand and ran our servers without issue for a full week ... aaaaaand then the problem recurred. Disable checksum offload, remove TProxy We also tried disabling TCP/IP checksum offload in the driver, no change. We're now pulling out TProxy and moving to a more traditional x-forwarded-for network arrangement without any fancy IP address rewriting. We'll see if that helps. Switch Virtualization providers On the off chance this was related to Hyper-V in some way (we do host Linux VMs on it), we switched to VMWare Server. No change. Switch host model We've reached the end of our troubleshooting rope and are now formally involving Microsoft support. They recommended changing the host model: http://en.wikipedia.org/wiki/Host_model http://technet.microsoft.com/en-us/magazine/2007.09.cableguy.aspx We did that, and.. we'll see.

    Read the article

  • How to ignore CDATA tags?

    - by Petre
    I'm trying to make an html parser, but when I load the html I get warnings like this Warning: DOMDocument::loadHTML() [domdocument.loadhtml]: Invalid char in CDATA 0x1C in Entity, line: 1302 Here is the code I use class Parser { public $url=null; public $html=null; public $tidy=null; public $head=null; public $head_xpath=null; function __construct($url){ $this->url=$url; $this->html=file_get_contents($this->url); $this->tidy=tidy_parse_string($this->html); $this->head=new DOMDocument(); $this->head->loadHTML($this->tidy->head()); $this->head_xpath= new DOMXPath($this->head); } } $x=new Parser("http://www.guardian.co.uk/politics/2012/mar/24/vince-cable-coalition-banking-row"); I searched around and found the LIBXML_NOCDATA constant, but I don't know how to set it. So how could i completely ignore CDATA?

    Read the article

  • Windows Mobile Development on MacBook Pro?

    - by Ted Nichols
    I am a frequent Windows Mobile application developer in need of a new development laptop. I am considering a MacBook or Macbook Pro running either Fusion from VMWare or Parallels Desktop. This will give me the option to port my applications to the iPhone depending on what MS does with WM 6.5 and 7. Has anybody tried doing Windows Mobile development using Microsoft Windows Mobile Device Center (or ActiveSync) and VS2008 on the MacBook Pro using one of these virtual machines? Does the device emulator work properly? What about debugging a Windows Mobile device over a USB cable? In general, do most USB drivers (non HID) designed for Windows work under these virtual machines? Thanks.

    Read the article

  • Hard to append a table with many records into another without generating duplicates

    - by Bill Mudry
    I may seem to be a bit wordy at first but for the hope it will be easier for all of you to understand what I am doing in the first place. I have an uncommon but enjoyable activity of collecting as many species of wood from around the world as I can (over 2,900 so far). Ok, that is the real world. Meanwhile I have spent over 8 years compiling over 5.8 meg of text data on all the woods of the world. That got so large that learning some basic PHP and MySQL was most welcome so I could build a new database driven home for all this research. I am still slow at it but getting there. The original premise was to find evidence of as many species of woods in the world I can. The more names identified, the more successful the project. I have named the project TAXA for ease of conversation (short for Taxonomy). You are most welcome to take a look at what I have so far at www.prowebcanada.com/taxa. It is 95% dynamically driven. So far I am reporting about 6,500 botanical wood names and, as said above, the more I can report, the more successful is the project. I have a file of all the woods in the second largest wood collection in the world, the Tervuren wood collection in the Netherlands with over 11,300 wood names even after cleaning out all duplicates. That is almost twice the number I am reporting now so porting all the new wood names from Tervuren to the 'species' table where I keep the reported data would be a major desirable advancement in the project. At one point I was able to add all the Tervuren records to the species table but over 3,000 duplicates also formed. They were not in the Tervuren file in the first place but represent the same wood names common to both files. It is common sense that there would be woods common to both that when merged would create new duplicates. At one point and with the help of others from another forum, I may very well have finally got the proper SQL statement. When I ran it, though, the system said (semi-amusingly at first) ----- that it had gone away! After looking up on the Net what could have have done this, one reason is that the MySQL timeout lapses and probably because of the large size of files I am running. I am running this on a rented account on Godaddy so I cannot go about trying to adjust any config file. For safety, I copied the tervuren.sql file as tervuren_target.sql and the species.sql file as species_master.sql tp use as working files just to make sure I protect the original files from destruction or damage. Later I can name the species_master back to just species.sql once I am happy all worked well. The species file has about 18 columns in it but only 5 columns match the columns in the Tervuren file (name for name and collation also). The rest of the columns are just along for the ride, so to speak. The common key in both is the 'species_name" columns in both. I am not sure it is at all proper to call one a primary key and the other a foreign key since there really is no relational connection to them. One is just more data for the other and can disappear after, never to be referred to the working code in the application. I have been very surprised and flabbergasted on how hard it can be to append records from one large table into another (with same column names plus others) without generating NEW duplicates in the first place. Watch out thinking that a SELECT DISTINCT statement may do the job because absolutely NO records in the species table must get destroyed in the process and there is no way (well, that I know of) to tell the 'DISTINCT" command this. Yes, the original 'species' table has duplicates in it even before all this but, trust me ---- they have to be removed the long hard way manually record by record or I will lose precious information. It is more important to just make sure no NEW duplicates form through bringing in new names in the tervuren_target.species_name into species.species_name. I am hoping and thinking that a straight SQL solution should work --- except for that nasty timeout. How do I get past that? Could it mean that I may have to turn to a PHP plus SQL method?? Or ..... would I have to break up the Tervuren files into a few smaller ones and run them independently (hope not....)" So far, what seems should be easy has proven to be unexpectedly tricky. I appreciate any help you can give but start from the assumption that this may be harder to do right than it may seem on the surface. By the way --- I am running a quad 64 bit system with Windows 7, so at least I have some fairly hefty power on the client end. I have a direct ethernet cable feeding a cable connection to the Internet. Once I get an algorithm and code working for this, I also have many other lists to process that could make the 'species' table grow even more. It could be equivalent to (ahem) lighting a rocket under my project (especially compared to do this record by record manually)! This is my first time in this forum, so I do not know how I can receive any replies. Do I have to to come back here periodically or are replies emailed out also? It would be great if you CC'd copies to me at billmudry at rogers.com :-) Much thanks for your patience and help, Bill Mudry Mississauga, Ontario Canada (next to Toronto).

    Read the article

  • No network packets sent immediately after quick physical disconnect and reconnect.

    - by Hans
    I am using Boost's ASIO libraries to establish a UDP connection to a remote server. To make sure the connection is active, every second a keep-alive message is sent to the server. I have noticed that if I unplug the network cable and reinsert it quickly, the first 2 or 3 keep-alive messages after the reinsert are never sent. I tested this by running wire-shark on the server. I have seen it take up to 5 seconds before the client starts sending out network traffic again. The client is running under Linux (2.6.2), if that helps.

    Read the article

  • SATA hard disk for laptop on Desktop PC

    - by Lawliet
    I know that this forum is for programming-related questions only, but I'm having this dilemma so here I go. Can I connect a laptop SATA hard disk to Desktop PC? Do I have to use some adapters or I can just plug in SATA power connector and SATA data cable like my Desktop hard disk is connected? I noticed that both laptop and desktop SATA disks use same connectors, but I'm afraid that I might fry my laptop hard disk because the SATA connector has both 12V and 5V voltage (given the fact that laptop hard disks has input voltage of 5V) Thanks in advance

    Read the article

  • MQ Connection - 2009 error

    - by user171523
    am connectting the MQ with below code. I am able connected to MQ successfully. My case is i place the messages to MQ every 1 min once. After disconnecting the cable i get a ResonCode error but IsConnected property still show true. Is this is the right way to check if the connection is still connected ? Or there any best pratcices around that. I would like to open the connection when applicaiton is started keep it open for ever. public static MQQueueManager ConnectMQ() { if ((queueManager == null) || (!queueManager.IsConnected)||(queueManager.ReasonCode == 2009)) { queueManager = new MQQueueManager(); } return queueManager; }

    Read the article

  • Simulating Ajax failures for QA testing

    - by womp
    Our first ASP.Net MVC/jQuery product is about to go to QA, and we're looking for a way for our QA guys to easily be able to simulate bad Ajax requests (without modifying the application code). A typical integration/UI test plan might be: Load page, click button "DoStuff" "DoStuff" fails Attempt button "DoStuff" again "DoStuff" succeeds Verify application state This is a simple test case - there will be cases with multiple failures and successes interspersed. Aside from "unplug your network cable" I'm looking for an easy way for our guys to simulate intermittent bad server responses. I'm open to any ideas so I won't go into too many details about our application setup or dependencies. How have you handled this?

    Read the article

  • Invalid Parametes value

    - by Sheery
    Hi Guys, I have an application build in C#, for saving sms, MMS and contacts from the mobile attached via data cable. i am able to save sms and contacts but it gives an error of invalid parameters, my code for saving is if (iRet == PCCSErrors.CONA_OK) { dataVersit = (CAContentAccess.CADataDefinitions.CA_DATA_VERSIT)Marshal.PtrToStructure(bufData, typeof(CAContentAccess.CADataDefinitions.CA_DATA_VERSIT)); byte[] bVersitObject = new byte[dataVersit.iDataLength]; Marshal.Copy(dataVersit.pbVersitObject, bVersitObject, 0, dataVersit.iDataLength); System.IO.Stream ios = System.IO.File.Open(fileDlg.FileName, System.IO.FileMode.Create); ios.Write(bVersitObject, bVersitObject.GetLowerBound(0), dataVersit.iDataLength); ios.Flush(); ios.Close(); } else { PCCAPIUtils.ShowErrorMessage("CAReadItem", iRet); }

    Read the article

  • Redirect Log output to sdcard on customer's phone

    - by Tom
    My customers are having a problem with my app, and I have been unable to reproduce the problem on my development phone. How to debug this problem? The android Log class is great, but my customers do not know how to use 'adb' or the USB debug cable. Is there some way to redirect Log output to a file on the phone's SD card? Then the customer could easily email the log file to me. Even if this redirection requires programming on my part, I could at least distribute a 'debug' version of the app. Thanks, Tom

    Read the article

  • what causes the .NET SerialPort class DataReceived event to fire?

    - by Klay
    I understand from the MSDN docs that the event DataReceived will not necessarily fire once per byte. But does anyone know what exactly is the mechanism that causes the event to fire? Does the receipt of each byte restart a timer that has to reach, say 10 ms between bytes, before the event fires? I ask because I'm trying to write an app that reads XML data coming in from a serial port. Because my laptop has no serial ports, I use a virtual serial port emulator. (I know, I know--I can't do anything about it ATM). When I pass data through the emulated port to my app, the event fires once for each XML record (about 1500 bytes). Perfect. But when a colleague at another office tries it with two computers connected by an actual cable, the DataReceived event fires repeatedly, after every 10 or so bytes of XML, which totally throws off the app.

    Read the article

  • Accept-Encoding headers being sent by browser but not received by server

    - by Daniel Jacobs
    I have been trying to debug this for weeks. All of the browsers on all of the clients on my home network are sending 'Accept-Encoding: gzip,deflate'. However, that header is somehow, somewhere being dropped before the request makes it to a web server. For example, http://www.whatsmyip.org/http_compression/ says 'No, your browser is not requesting compressed content'. I've used Fiddler to make sure that all of my browsers are indeed sending the header. I've swapped out my router. I've turned off all anti-virus software. Brighthouse/Roadrunner (the local cable ISP) says they are not doing any filtering (and I can't see why they would in this case). Any suggestions would be most welcome!

    Read the article

  • The mobile application cannot connect to the web service

    - by cancelledout
    Hello everyone. I have a mobile app webservice client that connects to a WCF webservice(on my PC) deployed in a WiMo Device. The OS is Windows Mobile 6.0. It is connected to my PC using a USB cable and ActiveSync 4.5. Problem: When I use a mobile emulator to run the application, it was able to connect to the web service successfully. But if I use the mobile phone to run the application, it cannot connect to the web service. However, I can view the webservice's test webpage using phone's browser(IE) (http://153.xxx.xxx.xxx:8080/Design_Time_Addresses/SOAP11demo/Service1/) Can you guys help me identify on what is wrong?

    Read the article

  • How to generate a video signal from Android device via USB?

    - by C.Rivlaldo
    Is it possible to create an application for Android, which can generate a video signal (HDMI or VGA) via USB? Any Android device has miniUSB port. Theoretically it's possible to create a small commutator device on microcontroller or microscheme, which will be a USB-host for Android device. You'll connect Android device with commutator and then connect commutator with monitor. For example, the scheme looks like: Android phone - commutator (USB-host) - TV/Monitor. Summary, I need to connect android phone with TV via miniUSB port. I found soft which can use miniUSB - HDMI cable, but those apps only for Motorolla Droid and HTC Evo. I'll glad to get links to existing apps or projects on that theme, to info about software generation HDMI-signal and connecting Android devices with another devices. Thank you and sorry for my bad english!

    Read the article

  • low latency data link pc to android

    - by steveh
    can anyone recommend a method for low latency bi-directional com link between my pc app and android slave app. the app i have works now via wifi but the latency is too slow (about 300mS), i'm looking to get it down to 10mS or so. the android is acting like a glorified remote control to the game on the pc. the apk displays a low res image and sends button presses back to the game and the round trip need to be quick i'm thinking the only option beside the network, is to connect a usb cable but i don't see a lot of support for that path and not even sure it would be lower latency than wifi any ideas please?

    Read the article

  • Net Neutrality FAIL [closed]

    - by leeand00
    I know I'll get into all kinds of trouble for bringing this up on SO, but considering that nearly all of us programmers depend on the Internet to get our jobs done, I really think it's worth looking into today's failure of our right to use the Internet by way of Lobbying ISPs. Although something tells me there will be retribution for the actions of the ISPs/tel cos/cable and their lobbyist since, lets face it...ISPs/Telcos didn't invent the Internet. I'm not going to be the one to do it, but um I think somebody already has...as everybody I talked to was having Internet connection problems today at work. Just thought this might be relevant to all of our jobs...in the U.S.A. at least. If you work at an Big evil ISPs, by all means...try and close this question. If you don't...and your just a chap who enjoys your Internet access...please RT this: Contact The Democrats Who Are Against Net Neutrality (Full List W/ Contact Info) http://bit.ly/aMSV0W #NetNeutralityFAIL net-neutrality

    Read the article

  • Installing Skype on Amazon EC2 instance

    - by Adrian
    For my application, I need to have Skype working on my Amazon EC2 Windows instance. I got the application installed and am able to log in, however, I can't make a phone call, since I am getting an 'Can't detect your sound card' error. Since I'm trying to inject audio from an audio file into the phone call, I don't need the sound card on the server. Thus, I need a way to bypass this error message. I have tried installing Virtual Audio Cable, which unfortunately didn't work (even though it worked on my desktop machine).

    Read the article

  • Send and receive data trough the power network

    - by luvieere
    I'm not interested in a hardware solution, I want to know about software that may "read" modulated signal received trough the power supply - some sort of a low-level driver that would access the power signal in a convenient place and demodulate it. Is there a way to receive signal from the computer's power supply? I'm interested in an API or library that would allow the computer to be seen as a node in a Power Line Communication network and receive data directly through the power cable, without the need for a converter. Is there any active research in this field? Edit: There is software that reads monitors and displays internal component voltages - DC voltage after being converted and filtered by the power supply - now I need is a method of data encoding that would be invariant to conversion and filtering, the original signal embedded in AC being present in some form within the converted DC signal.

    Read the article

  • How can I implement lazy loading on a page with 500+ images?

    - by Fedor
    I basically have a booking engine unit results page which must show 40 units and per each unit there's 1 large image of the first thumbnail and an X number of accompanying thumbnail images. I've been using the jquery lazy load plugin, but it's not thorough enough ( I'm invoking it on DOM Ready ), plus it doesn't really work in IE ( 50% of the clients use IE so it's a big issue ). What I think I really need to do is not really spit out the image but a fake element such as a span, and possibly modify my code such that if the user views the span, render it into an image element. <span src="/images/foo.gif"> The booking engine relies on JS so I think I might be forced to just rely on ajaxifying all the thumbnails and have event handlers on window scroll, etc in order for the page to be "usable" and load at an average time ( 2-3 seconds instead of 5-30s on high speed DSL/Cable ). I'd appreciate any examples or ideas.

    Read the article

  • VirtualBox: How to connect to Internet via wi-fi on Mac?

    - by Paul Riedel
    I installed VirtualBox with a Win XP VM on my Mac running OS 10.7.5. My Mac only has a wi-fi connection to the internet. On the settings for the virtual host, I set: Attached to: Bridged Adapter Name: en1: Wi-Fi (AirPort) Adapter Type: Intel PRO/1000 MT Desktop (82540EM) Promiscuous Mode: Deny Mac Address: Cable Connected: true Those are the settings I see around the internet as being correct, but I still can't ping anything. On my Mac I have internet sharing via Ethernet enabled (not sure if that matters). When I start up my WinXP VM, it asks me to install a bunch of hardware which I don't have any drivers to. Do I need to install any ethernet card drivers in order for the internet to work? Thank you!!

    Read the article

  • error msg in avr studio4

    - by shubhang
    i have recently purchased an AVR USB programmer from robokits.co.in, was trying to program atmeg8 using AVR studio4 and i get the following when i click on the program options: a problem occurred when executing the command. make sure u are using the correct programming method. current mode is ISP verify that the device is placed in the correct socket, and that the ISP cable is connected properly.check that the programming frequency specified in the main page is well below 1/4th of the clock frequency of the device. i have tried all that i could think of, i have checked the connections and the freq is below 1/4th of the device. but that doesn't solve this problem i have made the circuit for blinking LEDs program please help me out see the image for details thanking you

    Read the article

  • Ubuntu Wired network(ethernet does not work)

    - by badnaam
    It was working just fine, until the other day I yanked it out. The wireless works just fine on the same router. If I login to a windows 7 instance on this dual boot laptop then the ehternet works just fine. So it's not a hardware, cable or router issue. The card even gets an ip, but I can't connect to the internet. Here are the details from route, iptables, ifconfig, ping etc. Any ideas? I have been struggling with this for day, none seems to have an answer. http://pastie.org/954816

    Read the article

  • Installed Ubuntu 12.04.01 with Windows XP but lost access to Windows XP

    - by Bob D
    The First time I tried to install Ubuntu the installer installed it on my D drive. This resulted in only booting to Windows XP with no access to Ubuntu. I had to download a disk partitioning program to undo all of this. A tip from the Internet said to create a partition on the C drive for Ubuntu, so I did along with a Swap Partition. I did this manually because the installer on the CD would not do so and would not let me do so from within the installer program. With the fresh partitions created for Ubuntu I let the installer do its thing. The computer rebooted and came up in Ubuntu. I then installed WINE and all was well. Then I shut the computer down for the night. The next day I turned on the computer and it booted directly into Ubuntu. I can see the Windows partition and all the files but it will not allow me to switch to the Windows XP OS. Does not even give me a choice to do so. I have reinstalled Ubuntu several times and each time is the same, I cannot access Windows XP anymore. Right now I am in a fresh install with only whatever the installer installed. How do I fix this?! I have tried the hold the shift key to see if something called GRUB shows up, but no. I tried shifting the order of boot in GRUB but that did not work either. I tried using EasyBCD but that will not run. One symptom I do not understand, my monitor will post a graphic when the computer reboots that the cable is disconnected, this is normal. Then when the computer gets to the actual boot process it will display the splash screens etc and it did this for Windows XP as well. But now something new has popped up, while booting Ubuntu after where it probably should be showing me a menu to pick what OS I want to boot, the monitor posts "Input Unsupported" until Ubuntu loads. I have never seen it post this before, maybe a clue to someone.

    Read the article

  • An increase to 3 Gig of RAM slows down Ubuntu 10.04 LTS

    - by williepabon
    I have Ubuntu 10.04 running from an external hard drive (installed on an enclosure) connected via USB port. Like a month or so ago, I increased RAM on my pc from 2 Gigs to 3 Gigs. This resulted on extremely long boot times and slow application loads. While I was understanding the nature of my problem, I posted various threads on this forum ( Questions # 188417, 188801), where I was advised to gather speed tests, and other info on my machine. I was also suggested that I might have problems with the RAM installed. Initially, I did not consider that possibility because: 1) I did a memory test with a diagnostic program from DELL (My pc is from Dell) 2) My pc works fine with Windows XP (the default OS), no problems with memory 3) My pc works fine when booting with Ubuntu 10.10 memory stick, no speed problems 4) My pc works fine when booting with Ubuntu 11.10 memory stick, no speed problems Anyway, I performed the memory tests suggested. But before doing it, and to check out any possibility of hardware issues on the hard drive, I did the following: (1) purchased a new hard drive enclosure and moved my hard drive to it, (2) purchased a new USB cable and used it to connect my hard drive/enclosure setup to a different USB port on my pc. Then, I performed speed tests with 1 Gig, 2 Gigs and 3 Gigs of RAM with my Ubuntu 10.04 OS. Ubuntu 10.04 worked well when booted with 1 Gig or 2 Gigs of RAM. When I increased to 3 Gigs, it slowed down to a crawl. I can't understand the relationship between an increase of 1 Gig and the effect it has in Ubuntu 10.04. This doesn't happen with Ubuntu 10.10 and 11.10. Unfortunately for me, Ubuntu 10.04 is my principal work operating system. So, I need a solution for this. Hardware and system information: DELL Precision 670 2 internal SATA Hard drives Audigy 2 ZS audio system Factory OS: Windows XP Professional SP3 NVidia 8400 GTS video card More info: williepabon@WP-WrkStation:~$ uname -a Linux WP-WrkStation 2.6.32-38-generic #83-Ubuntu SMP Wed Jan 4 11:13:04 UTC 2012 i686 GNU/Linux williepabon@WP-WrkStation:~$ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 10.04.4 LTS Release: 10.04 Codename: lucid Speed test with the 3 Gigs of RAM installed: williepabon@WP-WrkStation:~$ sudo hdparm -tT /dev/sdc [sudo] password for williepabon: /dev/sdc: Timing cached reads: 84 MB in 2.00 seconds = 41.96 MB/sec Timing buffered disk reads: 4 MB in 3.81 seconds = 1.05 MB/sec This is a very slow transfer rate from a hard drive. I will really appreciate a solution or a work around for this problem. I know that that there are users that have Ubuntu 10.04 with 3 Gigs or more of RAM and they don't have this problem. Same question asked on Launchpad for reference.

    Read the article