Search Results

Search found 3145 results on 126 pages for 'cs brandt'.

Page 94/126 | < Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >

  • Linq-to-SQL produces bad SQL?

    - by strager
    I am trying to run a Linq-to-SQL query, but when the query is evaluated, I get the following exception: System.Data.OleDb.OleDbException was unhandled Message=The SELECT statement includes a reserved word or an argument name that is misspelled or missing, or the punctuation is incorrect. Source=Microsoft JET Database Engine ErrorCode=-2147217900 StackTrace: at System.Data.OleDb.OleDbCommand.ExecuteCommandTextErrorHandling(OleDbHResult hr) at System.Data.OleDb.OleDbCommand.ExecuteCommandTextForSingleResult(tagDBPARAMS dbParams, Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteCommandText(Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteCommand(CommandBehavior behavior, Object& executeResult) at System.Data.OleDb.OleDbCommand.ExecuteReaderInternal(CommandBehavior behavior, String method) at System.Data.OleDb.OleDbCommand.ExecuteReader(CommandBehavior behavior) at System.Data.OleDb.OleDbCommand.ExecuteDbDataReader(CommandBehavior behavior) at System.Data.Common.DbCommand.ExecuteReader() at System.Data.Linq.SqlClient.SqlProvider.Execute(Expression query, QueryInfo queryInfo, IObjectReaderFactory factory, Object[] parentArgs, Object[] userArgs, ICompiledSubQuery[] subQueries, Object lastResult) at System.Data.Linq.SqlClient.SqlProvider.ExecuteAll(Expression query, QueryInfo[] queryInfos, IObjectReaderFactory factory, Object[] userArguments, ICompiledSubQuery[] subQueries) at System.Data.Linq.SqlClient.SqlProvider.System.Data.Linq.Provider.IProvider.Execute(Expression query) at System.Data.Linq.DataQuery`1.System.Linq.IQueryProvider.Execute[S](Expression expression) at System.Linq.Queryable.FirstOrDefault[TSource](IQueryable`1 source) at xxx.InventoryPopulator`2.Clear(String barcode) in F:\Projects\C#\xxx\xxx\InventoryPopulator.cs:line 38 [..etc..] InnerException: The debugger shows my query is: SELECT [t0].[SupplierID] AS [Id], [t0].[SupplierSKU] AS [Sku], [t0].[LocalSKU] AS [LocalSku], [t0].[ManufacturersBarcode] AS [Barcode], [t0].[QuantityAvailable] FROM [inventorySupplier] AS [t0] WHERE [t0].[ManufacturersBarcode] = @p0 And the Linq query which generates the above is: var items = from item in this.supplierItems where item.Barcode == barcode select item; How do I fix my query?

    Read the article

  • TextBox doesn't fire TextChanged Event on IE 8, AutoPostback is true

    - by MaikoID
    Hi guys, I have the same thing, there are many TextBoxes with the event TextChanged set and with AutoPostback = true, and works in all browsers (Chrome, Opera, Firefox 3.6) except in IE 8, IE 6/7 I didn't test. I don't want to put the onblur event in all my TextBoxs because there are many pages with many TextBox that use this event. Description I'm using a masterPage, in the aspx i have <asp:TextBox ID="txtCnpj" runat="server" CssClass="txt" Width="200px" onkeyup="Mascara(this,Cnpj)" onkeydown="Mascara(this,Cnpj)" MaxLength="18" AutoPostBack="true" ValidationGroup="txtCnpj" OnTextChanged="txtCnpj_TextChanged"></asp:TextBox> in the aspx.cs protected void txtCnpj_TextChanged(object sender, EventArgs e) { if (CredorInvestimento.GetCredorInvestimento(txtCnpj.Text) != null) { ((TextBox)sender).Text = ""; ((TextBox)sender).Focus(); rfvCnpj.ErrorMessage = "Duplicado"; Page.Validate(txtCnpj.ID); } else txtNome.Focus(); } Thanks! ps: I really doesn't like of asp.net I spend more time fixing errors than developing new functions. ps: sorry for my english. ps: if i remove the onkeydown and onkeyup events the textchanged fire in IE, but i realy this events too.

    Read the article

  • Getting DirectoryNotFoundException when trying to Connect to Device with CoreCon API

    - by ageektrapped
    I'm trying to use the CoreCon API in Visual Studio 2008 to programmatically launch device emulators. When I call device.Connect(), I inexplicably get a DirectoryNotFoundException. I get it if I try it in PowerShell or in C# Console Application. Here's the code I'm using: static void Main(string[] args) { DatastoreManager dm = new DatastoreManager(1033); Collection<Platform> platforms = dm.GetPlatforms(); foreach (var p in platforms) { Console.WriteLine("{0} {1}", p.Name, p.Id); } Platform platform = platforms[3]; Console.WriteLine("Selected {0}", platform.Name); Device device = platform.GetDevices()[0]; device.Connect(); Console.WriteLine("Device Connected"); SystemInfo info = device.GetSystemInfo(); Console.WriteLine("System OS Version:{0}.{1}.{2}", info.OSMajor, info.OSMinor, info.OSBuildNo); Console.ReadLine(); } My question: Does anyone know why I'm getting this error? I'm running this on WinXP 32-bit, plain jane Visual Studio 2008 Pro. I imagine it's some config issue since I can't do it from a Console app or PowerShell. Here's the stack trace as requested: System.IO.DirectoryNotFoundException was unhandled Message="The system cannot find the path specified.\r\n" Source="Device Connection Manager" StackTrace: at Microsoft.VisualStudio.DeviceConnectivity.Interop.ConManServerClass.ConnectDevice() at Microsoft.SmartDevice.Connectivity.Device.Connect() at ConsoleApplication1.Program.Main(String[] args) in C:\Documents and Settings\Thomas\Local Settings\Application Data\Temporary Projects\ConsoleApplication1\Program.cs:line 23 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException:

    Read the article

  • Using VSTO in a standalone application to access Excel sheets

    - by chiccodoro
    Dear all, tried to research on that but sometimes I seem to lack some googling skills... I want to develop a (standalone) WinForms application which uses automation for communicating with Excel. I already know how to use the Interop, but I thought the VSTO tools would provide a more comfortable or sophisticated way to do that. My idea was: I could build a new standalone project with the excel references prepared. I could use a more sophisticated object model supplied by VSTO to communicate with Excel. However, my findings so far make me think that: VSTO can only be used to build add-ins/worksheets for Excel, not to build standalone application. There is no more sophisticated object model than the one provided by the Interop (which has such ugly things as a locale bug, a "Open(Missing, Missing, Missing...)" method and so on. I found a Worksheet and a Workbook class in the VSTO namespace, but as far as I understand it, these always refer to the CS classes for sheets and workbook which you implement when defining an Excel add-in or a workbook extension. - They cannot be used as comfortable wrappers in a standalone application. Can anybody confirm these statements or correct me where I am wrong? Further, if there should be a way to use VSTO and its "Workbook" class to load an excel workbook from a standalone application, then how do I do that? Thx, chiccodoro

    Read the article

  • How can I make a WPF combo box have the width of its widest element in XAML ?

    - by csuporj
    I know how to do it in code, but can this be done in XAML ? Window1.xaml: <Window x:Class="WpfApplication1.Window1" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" Title="Window1" Height="300" Width="300"> <Grid> <ComboBox Name="ComboBox1" HorizontalAlignment="Left" VerticalAlignment="Top"> <ComboBoxItem>ComboBoxItem1</ComboBoxItem> <ComboBoxItem>ComboBoxItem2</ComboBoxItem> </ComboBox> </Grid> </Window> Window1.xaml.cs: using System.Windows; using System.Windows.Controls; namespace WpfApplication1 { public partial class Window1 : Window { public Window1() { InitializeComponent(); double width = 0; foreach (ComboBoxItem item in ComboBox1.Items) { item.Measure(new Size( double.PositiveInfinity, double.PositiveInfinity)); if (item.DesiredSize.Width > width) width = item.DesiredSize.Width; } ComboBox1.Measure(new Size( double.PositiveInfinity, double.PositiveInfinity)); ComboBox1.Width = ComboBox1.DesiredSize.Width + width; } } }

    Read the article

  • Can't access CodeBase from a dynamically generated assembly.

    - by Michael Meadows
    I'm trying to create an assembly dynamically in .Net. I can't seem to figure out how to get the CodeBase property to return a value, however. Here's an example: var assemblyName = new AssemblyName { Name = "Whatever", CodeBase = Directory.GetCurrentDirectory() }; var assemblyBuilder = AppDomain.CurrentDomain .DefineDynamicAssembly(assemblyName, AssemblyBuilderAccess.RunAndSave); var moduleBuilder = assemblyBuilder.DefineDynamicModule("WhateverModule", "Whatever.dll"); var typeBuilder = moduleBuilder.DefineType("WhateverType", TypeAttributes.Public); var type = typeBuilder.CreateType(); assemblyBuilder.Save("Whatever.dll"); var codeBase = type.Assembly.CodeBase; // throws the below exception System.NotSupportedException was unhandled Message=The invoked member is not supported in a dynamic assembly. Source=mscorlib StackTrace: at System.Reflection.Emit.InternalAssemblyBuilder.get_CodeBase() at Stupid.Program.Main(String[] args) in C:\Users\Walking Disaster\Documents\Visual Studio 10\Projects\Lingual.Proxy\Stupid\Program.cs:line 25 at System.AppDomain._nExecuteAssembly(RuntimeAssembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean ignoreSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() Can anyone see what I'm doing wrong?

    Read the article

  • window.location.href not working in Safari when using onkeypress

    - by insanepaul
    I'm using an asp textbox and a search button. In Safari if I click the search button i get redirected to the search results page using javascript window.location.href. But strangely the same javascript will not redirect to the page if I press return in the textbox. Using the alert function I can see that window.location.href has the the correct url and the location bar at the top changes from the search page(default.aspx) to the search results url however when I click OK to the alert box the url at the top reverts back to the default.aspx page. It works on ie7/8/firefox/chrome but not safari. Here is my javascript,cs and aspx code: function submitSearchOnEnter(e) { var CodeForEnter = 13; var codeEnteredByUser; if (!e) var e = window.event; if (e.keyCode) codeEnteredByUser = e.keyCode; else if (e.which) codeEnteredByUser = e.which; if (codeEnteredByUser == CodeForEnter) RedirectToSearchPage(); } function RedirectToSearchPage() { var searchText = $get('<%=txtHeaderSearch.ClientID%>').value if (searchText.length) { window.location.href = "Search.aspx?searchString=" + searchText; } } protected void Page_Load(object sender, EventArgs e) { txtHeaderSearch.Attributes.Add("onkeypress", "submitSearchOnEnter(event)"); } <asp:Panel ID="pnlSearch" runat="server" DefaultButton="lnkSearch"> <asp:TextBox ID="txtHeaderSearch" runat="server" CssClass="searchBox"></asp:TextBox> <asp:LinkButton ID="lnkSearch" OnClientClick="RedirectToSearchPage(); return false;" CausesValidation="false" runat="server" CssClass="searchButton"> SEARCH </asp:LinkButton> </asp:Panel> I've tried return false; which doesn't allow me to enter any characters in the search box. I've spent ages online trying to find a solution. Maybe it has something to do with setTimeout or setTimeInterval but it didn't work unless i did it wrong.

    Read the article

  • jQuery HOW TO?? pass additional parameters to success callback for $.ajax call ?

    - by dotnetgeek
    Hello jQuery Ninjas! I am trying, in vain it seems, to be able to pass additional parameters back to the success callback method that I have created for a successful ajax call. A little background. I have a page with a number of dynamically created textbox / selectbox pairs. Each pair having a dynamically assigned unique name such as name="unique-pair-1_txt-url" and name="unique-pair-1_selectBox" then the second pair has the same but the prefix is different. In an effort to reuse code, I have crafted the callback to take the data and a reference to the selectbox. However when the callback is fired the reference to the selectbox comes back as 'undefined'. I read here that it should be doable. I have even tried taking advantage of the 'context' option but still nothing. Here is the script block that I am trying to use: <script type="text/javascript" language="javascript"> $j = jQuery.noConflict(); function getImages(urlValue, selectBox) { $j.ajax({ type: "GET", url: $j(urlValue).val(), dataType: "jsonp", context: selectBox, success:function(data){ loadImagesInSelect(data, $j(this)) } , error:function (xhr, ajaxOptions, thrownError) { alert(xhr.status); alert(thrownError); } }); } function loadImagesInSelect(data, selectBox) { //var select = $j('[name=single_input.<?cs var:op_unique_name ?>.selImageList]'); var select = selectBox; select.empty(); $j(data).each(function() { var theValue = $j(this)[0]["@value"]; var theId = $j(this)[0]["@name"]; select.append("<option value='" + theId + "'>" + theValue + "</option>"); }); select.children(":first").attr("selected", true); } From what I have read, I feel I am close but I just cant put my finger on the missing link. Please help in your typical ninja stealthy ways. TIA

    Read the article

  • Extension methods in class library project

    - by Mostafa
    I've implemented some extension methods and put those in separate Class Library project. Imagine I have a simple extension method like this in class library called MD.Utility: namespace MD.Utility { public static class ExtenMethods { public static bool IsValidEmailAddress(this string s) { Regex regex = new Regex(@"^[\w-\.]+@([\w-]+\.)+[\w-]{2,4}$"); return regex.IsMatch(s); } } } But nowhere in WebApp like App_code folder or WebFroms code-behind page I can't use this Extension method. If I do like this: using System; using System.Collections.Generic; using System.Linq; using System.Web; using System.Web.UI; using System.Web.UI.WebControls; using MD.Utility; public partial class _Default : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { string email = "[email protected]"; if (email.IsValidEmailAddress()) { //To do } } } The compiler doesn't recognize IsValidEmailAddress() and even no intellisense support. While if I put my extension method in App_Code folder it's ok for using in another cs file in App_code Folder or Web Form code-behind pages.

    Read the article

  • fill dropdown list by querystring

    - by KareemSaad
    I had drop down list and I want to fill it with data by specific condition i used this code but it was,t worked well <cs> protected void Page_Load(object sender, EventArgs e) { Page.Title = "ThumbnailViewPage"; if (Request.QueryString["Category_Id"] != null) { using (SqlConnection Con = Connection.GetConnection()) { SqlCommand Com = new SqlCommand("GetProducFamilyTP2", Con); Com.CommandType = CommandType.StoredProcedure; Com.Parameters.Add(Parameter.NewInt("@Category_Id", Request.QueryString["Category_Id"])); SqlDataReader DR = Com.ExecuteReader(); if (DR.Read()) { DDlProductFamily.DataTextField = DR["Name"].ToString(); DDlProductFamily.DataValueField = DR["ProductCategory_Id"].ToString(); } } } else if (Request.QueryString["ProductCategory_Id"] != null) { using (SqlConnection Con = Connection.GetConnection()) { SqlCommand Com = new SqlCommand("GetProducFamilyTP3", Con); Com.CommandType = CommandType.StoredProcedure; Com.Parameters.Add(Parameter.NewInt("@ProductCategory_Id", Request.QueryString["ProductCategory_Id"])); SqlDataReader DR = Com.ExecuteReader(); if (DR.Read()) { DDlProductFamily.DataTextField = DR["Name"].ToString(); DDlProductFamily.DataValueField = DR["ProductCategory_Id"].ToString(); } } } } <asp:UpdatePanel ID="UpdatePanel3" runat="server"> <ContentTemplate> <asp:DropDownList ID="DDlProductFamily" runat="server" ondatabound="DDlProductFamily_DataBound" onload="DDlProductFamily_Load" onselectedindexchanged="DDlProductFamily_SelectedIndexChanged"> </asp:DropDownList> </ContentTemplate> <Triggers> <asp:AsyncPostBackTrigger ControlID="DDlProductFamily" EventName="SelectedIndexChanged" /> </Triggers> </asp:UpdatePanel>

    Read the article

  • How can I test that my hash function is good in terms of max-load?

    - by philcolbourn
    I have read through various papers on the 'Balls and Bins' problem and it seems that if a hash function is working right (ie. it is effectively a random distribution) then the following should/must be true if I hash n values into a hash table with n slots (or bins): Probability that a bin is empty, for large n is 1/e. Expected number of empty bins is n/e. Probability that a bin has k collisions is <= 1/k!. Probability that a bin has at least k collisions is <= (e/k)**k. These look easy to check. But the max-load test (the maximum number of collisions with high probability) is usually stated vaguely. Most texts state that the maximum number of collisions in any bin is O( ln(n) / ln(ln(n)) ). Some say it is 3*ln(n) / ln(ln(n)). Other papers mix ln and log - usually without defining them, or state that log is log base e and then use ln elsewhere. Is ln the log to base e or 2 and is this max-load formula right and how big should n be to run a test? This lecture seems to cover it best, but I am no mathematician. http://pages.cs.wisc.edu/~shuchi/courses/787-F07/scribe-notes/lecture07.pdf BTW, with high probability seems to mean 1 - 1/n.

    Read the article

  • How can I create a dynamic LINQ query in C# with possible multiple group by clauses?

    - by FordPrefect141
    I have been a programmer for some years now but I am a newcomer to LINQ and C# so forgive me if my question sounds particularly stupid. I hope someone may be able to point me in the right direction. My task is to come up with the ability to form a dynamic multiple group by linq query within a c# script using a generic list as a source. For example, say I have a list containing multiple items with the following structure: FieldChar1 - character FieldChar2 - character FieldChar3 - character FieldNum1 - numeric FieldNum2 - numeric In a nutshell I want to be able to create a LINQ query that will sum FieldNum1 and FieldNum2 grouped by any one, two or all three of the FieldChar fields that will be decided at runtime depending on the users requirements as well as selecting the FieldChar fields in the same query. I have the dynamic.cs in my project which icludes a GroupByMany extension method but I have to admit I am really not sure how to put these to use. I am able to get the desired results if I use a query with hard-wired group by requests but not dynamically. Apologies for any erroneous nomenclature, I am new to this language but any advice would be most welcome. Many thanks Alex

    Read the article

  • Create custom culture in ASP.NET

    - by Billy
    I want to create a resource file for Singaporean English (en-sg) named "shopping.en-sg.resx" in App_GlobalResources folder. I get error during compilation. Error 1 The namespace 'Resources' already contains a definition for 'shopping' c:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\web\2cd6afe9\737b0a13\App_GlobalResources.vomuzavz.1.cs 26 After searching Google, I discover that "en-sg" is not a default culture and I have to create custom culture for it. I don't know the detailed steps of this. What should I do to create the culture and remove the compilation error? I follow the example in MSDN, create a file called "shopping.x-en-US-sample.resx" and put the following code into BasePage's function (protected override void InitializeCulture()): CultureAndRegionInfoBuilder cib = null; cib = new CultureAndRegionInfoBuilder( "x-en-US-sample", CultureAndRegionModifiers.None); CultureInfo ci = new CultureInfo("en-US"); cib.LoadDataFromCultureInfo(ci); RegionInfo ri = new RegionInfo("US"); cib.LoadDataFromRegionInfo(ri); cib.Register(); ci = new CultureInfo("x-en-US-sample"); However, compilation error is still exist. UPDATED: You can easily reproduce the problem by creating an empty website and two files "shopping.en-sg.resx" and "shopping.resx" in the app_globalresources folder.

    Read the article

  • Why won't my image display??

    - by Josh
    Hello All- Do y'all see anything wrong with my code below? I want my image to appear immediately after page opens but it only opens after the report is run. Please let me know. Thanks. <%@ Page Language="C#" AutoEventWireup="true" CodeBehind="SelectionReport.aspx.cs" Inherits="Geocortex.Essentials.WebFramework.SelectionReportPage" Culture="auto" UICulture="auto" %> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml" > <head id="Head1" runat="server"> <title><asp:Literal meta:resourcekey="Title1" runat="server" /></title> </head> <body> <form id="form1" runat="server"> <p> <asp:Image ID="Image1" runat="server" ImageAlign="Left" ImageUrl="~/Images/Loading.gif" style="z-index: 1; left: 254px; top: 15px; position: absolute" /> </p> <gcx:SelectionReportViewer ID="SelectionReportViewer" runat="server" /> </form> </body>

    Read the article

  • Validation of viewstate MAC failed with nested master page

    - by just_name
    After I use a nested master page ,I face the following problem : Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster. and sometimes Invalid related information [ViewStateException: Invalid viewstate. Client IP: 127.0.0.1 Port: User-Agent: Mozilla/5.0 (Windows NT 6.1; WOW64; rv:17.0) Gecko/20100101 Firefox/17.0 ViewState: 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...] [HttpException (0x80004005): Validation of viewstate MAC failed. If this application is hosted by a Web Farm or cluster, ensure that <machineKey> configuration specifies the same validationKey and validation algorithm. AutoGenerate cannot be used in a cluster.] System.Web.UI.ViewStateException.ThrowError(Exception inner, String persistedState, String errorPageMessage, Boolean macValidationError) +116 System.Web.UI.ViewStateException.ThrowMacValidationError(Exception inner, String persistedState) +13 System.Web.UI.ObjectStateFormatter.Deserialize(String inputString) +220 System.Web.UI.ObjectStateFormatter.System.Web.UI.IStateFormatter.Deserialize(String serializedState) +5 System.Web.UI.Util.DeserializeWithAssert(IStateFormatter formatter, String serializedState) +37 System.Web.UI.HiddenFieldPageStatePersister.Load() +202 System.Web.UI.Page.LoadPageStateFromPersistenceMedium() +106 System.Web.UI.Page.LoadAllState() +43 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +3905 System.Web.UI.Page.ProcessRequest(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +262 System.Web.UI.Page.ProcessRequest() +79 System.Web.UI.Page.ProcessRequestWithNoAssert(HttpContext context) +21 System.Web.UI.Page.ProcessRequest(HttpContext context) +109 ASP.frm_items2_aspx.ProcessRequest(HttpContext context) in c:\Windows\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\root\a961040e\19f53d4c\App_Web_frm_items2.aspx.cdcab7d2.nkfrbsfi.0.cs:0 System.Web.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +399 System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +76 I use this Tool to fix this problem but in vain !! I don't know even the root cause of this problem !!

    Read the article

  • Debugging a HTTP Handler from Visual Studio

    - by O.O.
    I am trying to debug a HTTP Handler in Visual Studio and the break point is not getting hit. Does anyone have an idea on how to go about debugging HTTP Handlers in Visual Studio? I am using VS 2010 Premium, .NET 4.0 on a Windows 7 machine. In my Web Application I have a HTTP Handler in /HTTPHandler/TrackingHandler.cs The following is in my web config file: <system.webServer> <handlers> <add name="TrackingHandler" path="/tx/*" verb="*" type="ProjectNamespace.TrackingHandler" resourceType="Unspecified" preCondition="integratedMode" /> </handlers> </system.webServer> My HTTP Handler looks like below namespace ProjectNamespace { public class TrackingHandler : IHttpHandler { public bool IsReusable { get { return true; } } public void ProcessRequest(HttpContext context) { //Breakpoint on the very first line below string tracker = Path.GetFileName(context.Request.PhysicalPath); ....... } } } I start my Web Application using any random page in Visual Studio Debug using the builtin Web Server. I then maually edit the URL to point to the /tx/ directory and some random string after it. For e.g. my current URL looks like http://localhost:53699/tx/sdfs. I thought this should pull up the breakpoint on the first line of ProcessRequest() but it does not. I’d be grateful for any ideas. O. O.

    Read the article

  • SQL Express under IIS 7.5

    - by fampinheiro
    I´m developing a web service that access a SQL Express database, it works very well in the Visual Studio host but when i deploy it to IIS 7.5 i get this exception. Please help me. Stack Trace: System.Data.EntityException: The underlying provider failed on Open. ---> System.Data.SqlClient.SqlException: Failed to generate a user instance of SQL Server due to failure in retrieving the user's local application data path. Please make sure the user has a local user profile on the computer. The connection will be closed. at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection) at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj) at System.Data.SqlClient.SqlInternalConnectionTds.CompleteLogin(Boolean enlistOK) at System.Data.SqlClient.SqlInternalConnectionTds.AttemptOneLogin(ServerInfo serverInfo, String newPassword, Boolean ignoreSniOpenTimeout, Int64 timerExpire, SqlConnection owningObject) at System.Data.SqlClient.SqlInternalConnectionTds.LoginNoFailover(String host, String newPassword, Boolean redirectedUserInstance, SqlConnection owningObject, SqlConnectionString connectionOptions, Int64 timerStart) at System.Data.SqlClient.SqlInternalConnectionTds.OpenLoginEnlist(SqlConnection owningObject, SqlConnectionString connectionOptions, String newPassword, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlInternalConnectionTds..ctor(DbConnectionPoolIdentity identity, SqlConnectionString connectionOptions, Object providerInfo, String newPassword, SqlConnection owningObject, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionFactory.CreatePooledConnection(DbConnection owningConnection, DbConnectionPool pool, DbConnectionOptions options) at System.Data.ProviderBase.DbConnectionPool.CreateObject(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.UserCreateRequest(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.GetConnection(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionFactory.GetConnection(DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionClosed.OpenConnection(DbConnection outerConnection, DbConnectionFactory connectionFactory) at System.Data.SqlClient.SqlConnection.Open() at System.Data.EntityClient.EntityConnection.OpenStoreConnectionIf(Boolean openCondition, DbConnection storeConnectionToOpen, DbConnection originalConnection, String exceptionCode, String attemptedOperation, Boolean& closeStoreConnectionOnFailure) --- End of inner exception stack trace --- at System.Data.EntityClient.EntityConnection.OpenStoreConnectionIf(Boolean openCondition, DbConnection storeConnectionToOpen, DbConnection originalConnection, String exceptionCode, String attemptedOperation, Boolean& closeStoreConnectionOnFailure) at System.Data.EntityClient.EntityConnection.Open() at System.Data.Objects.ObjectContext.EnsureConnection() at System.Data.Objects.ObjectQuery`1.GetResults(Nullable`1 forMergeOption) at System.Data.Objects.ObjectQuery`1.System.Collections.Generic.IEnumerable<T>.GetEnumerator() at System.Linq.Enumerable.FirstOrDefault[TSource](IEnumerable`1 source) at WSCinema.CinemaService.Movie() in D:\Documents\My Dropbox\Projects\sd.v0910\trab3\code\WSCinema\CinemaService.asmx.cs:line 46

    Read the article

  • Bind SQLiteDataReader to GridView in ASP.NET

    - by Charles Gargent
    Hi, this is all rather new to me, but I have searched for a good while and cant find any idea why I cant get this to work, dr looks like it is populated but I get this nullreferenceexeception when I try to bind to the gridview Thanks code SQLiteConnection cnn = new SQLiteConnection(@"Data Source=c:\log.db"); cnn.Open(); SQLiteCommand cmd = new SQLiteCommand(@"SELECT * FROM evtlog", cnn); SQLiteDataReader dr = cmd.ExecuteReader(); GridView1.DataSource = dr; GridView1.DataBind(); dr.Close(); cnn.Close(); Codebehind <asp:ContentPlaceHolder ID="MainContent" runat="server"> <asp:GridView ID="GridView1" runat="server"> </asp:GridView> </asp:ContentPlaceHolder> error Object reference not set to an instance of an object. at WPKG_Report.SiteMaster.Button1_Click(Object sender, EventArgs e) in C:\Projects\Report\Site.Master.cs:line 32 at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

    Read the article

  • Using Build Manager Class to Load ASPX Files and Populate its Controls

    - by Sandhurst
    I am using BuildManager Class to Load a dynamically generated ASPX File, please note that it does not have a corresponding .cs file. Using Following code I am able to load the aspx file, I am even able to loop through the control collection of the dynamically created aspx file, but when I am assigning values to controls they are not showing it up. for example if I am binding the value "Dummy" to TextBox control of the aspx page, the textbox remains empty. Here's the code that I am using protected void Page_Load(object sender, EventArgs e) { LoadPage("~/Demo.aspx"); } public static void LoadPage(string pagePath) { // get the compiled type of referenced path Type type = BuildManager.GetCompiledType(pagePath); // if type is null, could not determine page type if (type == null) throw new ApplicationException("Page " + pagePath + " not found"); // cast page object (could also cast an interface instance as well) // in this example, ASP220Page is a custom base page System.Web.UI.Page pageView = (System.Web.UI.Page)Activator.CreateInstance(type); // call page title pageView.Title = "Dynamically loaded page..."; // call custom property of ASP220Page //pageView.InternalControls.Add( // new LiteralControl("Served dynamically...")); // process the request with updated object ((IHttpHandler)pageView).ProcessRequest(HttpContext.Current); LoadDataInDynamicPage(pageView); } private static void LoadDataInDynamicPage(Page prvPage) { foreach (Control ctrl in prvPage.Controls) { //Find Form Control if (ctrl.ID != null) { if (ctrl.ID.Equals("form1")) { AllFormsClass cls = new AllFormsClass(); DataSet ds = cls.GetConditionalData("1"); foreach (Control ctr in ctrl.Controls) { if (ctr is TextBox) { if (ctr.ID.Contains("_M")) { TextBox drpControl = (TextBox)ctr; drpControl.Text = ds.Tables[0].Rows[0][ctr.ID].ToString(); } else if (ctr.ID.Contains("_O")) { TextBox drpControl = (TextBox)ctr; drpControl.Text = ds.Tables[1].Rows[0][ctr.ID].ToString(); } } } } } } }

    Read the article

  • Passing data to a non-static listBox, by calling function from another class

    - by Andrew A
    I have a simple forms program that I have been fighting with for a while now. I simply want to be able to call a method from a different class file (when a certain step is triggered in the code in that class file) in order to insert a string in the listBox. Here is my main method, pretty standard: class Program { [STAThread] static void Main(string[] args) { Application.EnableVisualStyles(); Application.SetCompatibleTextRenderingDefault(false); Application.Run(new MainForm()); } } Here is the function which resides in my MainForm.cs file, which I can call just fine from that class file (via 'TextToBox(myString);'): public partial class MainForm : Form { ... // Function to output results to main Listbox window public void TextToBox(string aString) { // Place messages in Main Display list box window this.listBox1.Items.Insert(0, aString); } ... } But my problem is when I am in another class and I want to call 'TextToBox(myString);'. If I create another object reference of the MainForm, the code compiles fine but nothing will show up in the listBox. How do I do this? I cannot simply make TextToBox() static. I know I must create the object reference but I can't figure out how to reference the ORIGINAL MainForm, the one that was created in the Main method. Thanks in advance...

    Read the article

  • JQuery Autocomplete plugin not working with JQuery 1.4.1

    - by Russ Clark
    I've been using the JQuery Autocomplete plugin with JQuery version 1.3.2, and it has been working great. I recently updated JQuery in my project to version 1.4.2, and the Autocomplete plugin is now broken. The JQuery code to add items to a textbox on my web page doesn't seem to be getting called at all. Does anyone know if the JQuery Autocomplete plugin is incompatible with JQuery version 1.4.2, and if there is a fix for this problem? Here is some sample code I've built in an ASP.Net web site (which works fine if I change the JQuery file to jquery-1.3.2.js, but nothing happens using jquery-1.4.2.js): <%@ Page Language="C#" AutoEventWireup="true" CodeFile="Default.aspx.cs" Inherits="_Default" %> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head runat="server"> <title>Untitled Page</title> <script type="text/javascript" src="js/jquery-1.4.2.js" ></script> <script type="text/javascript" src="js/jquery.autocomplete.js" ></script> <script type="text/javascript"> $(document).ready(function() { var data = "Core Selectors Attributes Traversing Manipulation CSS Events Effects Ajax Utilities".split(" "); $(':input:text:id$=sapleUser').autocomplete(data); }); </script> </head> <body> <form id="form1" runat="server"> API Reference: <input id="sapleUser" autocomplete="off" type="text" runat="server" /> (try "C" or "E") </form> </body> </html>

    Read the article

  • How to catch HttpRequestValidationException in production

    - by bruno
    Hello all, I have this piece of code to handle the HttpRequestValidationException in my global.asax.cs file. protected void Application_Error(object sender, EventArgs e) { var context = HttpContext.Current; var exception = context.Server.GetLastError(); if (exception is HttpRequestValidationException) { Response.Clear(); Response.StatusCode = 200; Response.Write(@"<html><head></head><body>hello</body></html>"); Response.End(); return; } } If I debug my webapplication, it works perfect. But when i put it on our production-server, the server ignores it and generate the "a potentially dangerous request.form value was detected from the client" - error page. I don't know what happens exactly... If anybody knows what the problem is, or what i do wrong..? Also I don't want to set the validaterequest on false in the web.config. The server uses IIS7.5, And I'm using asp.net 3.5. Thanks, Bruno

    Read the article

  • How does Select statement works in a Dynamic Linq Query?

    - by Richard77
    Hello, 1) I've a Product table with 4 columns: ProductID, Name, Category, and Price. Here's the regular linq to query this table. public ActionResult Index() { private ProductDataContext db = new ProductDataContext(); var products = from p in db.Products where p.Category == "Soccer" select new ProductInfo { Name = p.Name, Price = p.Price} return View(products); } Where ProductInfo is just a class that contains 2 properties (Name and Price). The Index page Inherits ViewPage - IEnumerable - ProductInfo. Everything works fine. 2) To dynamicaly execute the above query, I do this: Public ActionResult Index() { var products = db.Products .Where("Category = \"Soccer\"") .Select(/* WHAT SOULD I WRITE HERE TO SELECT NAME & PRICE?*/) return View(products); } I'm using both 'System.Lind.Dynamic' namespace and the DynamicLibrary.cs (downloaded from ScottGu blog). Here are my questions: What expression do I use to select only Name and Price? (Most importantly) How do I retrieve the data in my view? (i.e. What type the ViewPage inherits? ProductInfo?)

    Read the article

  • Mathematics for Computer Science Students

    - by Ender
    To cut a long story short, I am a CS student that has received no formal Post-16 Maths education for years. Right now even my Algebra is extremely rusty and I have a couple of months to shape up my skills. I've got a couple of video lectures in my bookmarks, consisting of: Pre-Calculus Algebra Calculus Probability Introduction to Statistics Differential Equations Linear Algebra My aim as of today is to be able to read the CLRS book Introduction to Algorithms and be able to follow the Mathematical notation in that, as well as being able to confidently read and back-up any arguments written in Mathematical notation. Aside from these video lectures, can anyone recommend any good books to help teach someone wishing to go from a low-foundation level to a more advanced level of Mathematics? Just as a note, I've taken a first-year module in Analytical Modelling, so I understand some of the basic concepts of Discrete Mathematics. EDIT: Just a note to those that are looking to learn Linear Algebra using the Video Lectures I have posted up. Peteris Krumins' Blog contains a run-through of these lecture notes as well as his own commentary and lecture notes, an invaluable resource for those looking to follow the lectures too.

    Read the article

  • Is there a way to avoid spaghetti code over the years?

    - by Yoni Roit
    I've had several programming jobs. Each one with 20-50 developers, project going on for 3-5 years. Every time it's the same. Some programmers are bright, some are average. Everyone has their CS degree, everyone read design patterns. Intentions are good, people are trying hard to write good code but still after a couple of years the code turns into spaghetti. Changes in module A suddenly break module B. There are always these parts of code that no one can understand except for the person who wrote it. Changing infrastructure is impossible and backwards compatibility issues prevent good features to get in. Half of the time you just want to rewrite everything from scratch. And people more experienced than me treat this as normal. Is it? Does it have to be? What can I do to avoid this or should I accept it as a fact of life? Edit: Guys, I am impressed with the amount and quality of responses here. This site and its community rock!

    Read the article

< Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >