Search Results

Search found 15209 results on 609 pages for 'configuration'.

Page 163/609 | < Previous Page | 159 160 161 162 163 164 165 166 167 168 169 170  | Next Page >

  • Howto configure openSuSE firewall to route local traffic to local ports

    - by Eduard Wirch
    I have openSUSE 11.3 installed. I'm using the openSUSE firewall configuration mechanism (/etc/sysconfig/SuSEfirewall2). I have a http server application running on port 8080. I want the http service to be accessible using port 80. I created a redirect rule usign: FW_REDIRECT="0/0,0/0,tcp,80,8080" This works fine for every request coming from external. But it doesn't for local requests. (example: wget http://myserver/) Is there a way how I can tell the firewall to redirect local requests addressed for 80 to port 8080? (using the SUSE firewall configuration file)

    Read the article

  • Exchange 2010 Deployment Notes - ISA 2004 Server Issue

    - by BWCA
    An interesting ISA 2004 tidbit … While we were setting up our Exchange 2010 ActiveSync environment, we encountered a problem where we could not successfully telnet over port 443 from one of our ISA 2004 Servers to our Exchange 2010 Client Access Server Array. When we tried to telnet over port 443 from the ISA Server to the Client Access Server Array name, we would get a “Could not open connection to the host on port 443: Connect failed” error message. Also, when we used portqry over port 443 from the ISA Server to the Client Access Server Array name, we would get a “Error opening socket: 10065” and “No route to host” error messages. It was odd because we did not have any problems with using ping or tracert from the ISA Server to the Client Access Server Array and our firewall firewall policy was allowing 443 traffic to pass through. After some troubleshooting, we were able to telnet and use portqry over port 443 successfully if we stopped the Microsoft Firewall service on the ISA 2004 Server.  So, it was strictly a problem with ISA.  Eventually, we were able to isolate the problem to a ISA 2004 Server System Policy setting as shown below (to modify the System Policy, right-click Firewall Policy and click Edit System Policy). Under the Diagnostics Services – HTTP Connectivity verifiers Configuration Group, you need to enable the configuration group under the General tab to resolve the problem.  After we enabled the setting, we no longer had a problem.

    Read the article

  • Exim: How to turn off DKIM for forwarded mail?

    - by Andrew
    I have DKIM configured in Exim for outgoing mail, as per the documentation. Exim signs all outgoing mail. But some of that outgoing mail is forwarded, thanks to a users .forward file. This is a problem for me, because some of those messages are spam (my exim configuration does not do any verification) and I don't want to take responsibility for them. But I can't figure out how to configure Exim not to sign these messages. My configuration is basically the Debian Squeeze default, with a few DKIM_* macros set. I can post more details, but I think seeing any example of conditional DKIM signing would set me right.

    Read the article

  • APC Not Enabled (WHM on CentOS)

    - by gamerzfuse
    I know this questions has been beat to death, but I've read almost all the responses and it hasn't solved my issue. I installed APC (no noted errors), I told PHP.ini to enable it and I made sure I am running PHP in FastCGI with SuExec turned off. Still I have no go. PHP / suEXEC Configuration Default PHP Version (.php files) 5 PHP 5 Handler fcgi PHP 4 Handler none Apache suEXEC off Apache Ruid2 off php.ini Configuration Alternative PHP Cache apc.enabled Alternative PHP Cache apc.shm_segments Alternative PHP Cache apc.shm_size When I run the APC.php file I get this message: No cache info available. APC does not appear to be running.

    Read the article

  • Bacula Director and Storage in LAN

    - by B14D3
    I have two networks LAN and DMZ.. Machines in DMZ are accesible from internet ( only over http). In LAN I have servers that see all LAN and all DMZ machines but machinse from DMZ don't see any LAN servers. Machines in LAN have access only to all LAN and DMZ, no direct access to internet and no access from internet. DMZ <------ LAN DMZ ----X--->LAN I'm planning to configure Bacula as major backup system. My plan is to install Bacula Director and Storage deamon on the same server in LAN for safety reasons. So my question is: Will this configuration work, is it posible for bacula director and storage deamon installed on server in LAN to makes backup servers that are in my DMZ? Or in this network configuration Bacula should be in DMZ? (If yes will I can backup with it servers in LAN ?)

    Read the article

  • Trying to install Canon LBP7750Cdn driver on Ubuntu 12.04

    - by Gideon
    I'n new to Ubuntu/Linux and had significant difficulties while attempting to configure my printer to work. The automatic driver pairing wizard which Ubuntu uses to identify and install the appropriate drivers did not find my printer's driver. I managed to get it to print when I manually select the generic configuration and checked the PCL6 configuration. However, the printer driver wizard does provide a list of Canon printers and actually do specify my printer as LBP7750C (minus the "dn" at the end, I'm assuming its because duplex ability and networking is not present on all the models - I'm not sure if this could be the source of the problem), but in selecting this option and trying to print I receive this message: Idle - /usr/lib/cups/filter/foomatic-rip failed I searched for this similar problem which other users might have encountered, but while there where plenty of such cases, they all had different resolutions and were all related to HP printers. Canon actually do provide a driver for my printer, but it comes with no installation instructions unless you consider yourself an experienced CUPS guru. Seriously. If anyone can help me solve this foomatic-rip failed problem I'd be really grateful - and I'm sure many other folks too. [BTW, can't Canonical fix this type of thing for the next Ubuntu release? - I't seems like a small problem but it causes many problems and countles hours of production time loss.] Thanks in advance.

    Read the article

  • "Enable Wireless" option is disabled in network settings

    - by silenTK
    I'm using Ubuntu 11.10 (dual booted with Windows 7) but I'm unable to access Internet wireless even though I can do so on Windows 7. The output for rfkill list all is given below: rfkill list all 0: brcmwl-0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no The output for sudo lshw -C network *-network DISABLED is: description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth1 version: 01 serial: 11:11:11:11:11:11 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:16 memory:c2500000-c2503fff *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 05 serial: 22:22:22:22:22:22 size: 100Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8105e-1.fw latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:42 ioport:3000(size=256) memory:c0404000-c0404fff memory:c0400000-c0403fff Broadcom STA wireless driver is installed, activated, and currently in use. My laptop is a HP-Pavilion-g6-1004tx. My hardware switch is on. Enable Wireless option is also disabled in network settings.

    Read the article

  • Allow from referer for HTTP-basic protected SSL apache site

    - by user64204
    I have an apache site protected by HTTP basic authentication. The authentication is working fine. Now I would like to bypass authentication for users that are coming from a particular website by relying on the HTTP Referer header. Here is the configuration: SetEnvIf Referer "^http://.*.example\.org" coming_from_example_org <Directory /var/www/> Options Indexes FollowSymLinks MultiViews AllowOverride None Deny from all Allow from env=coming_from_example_org AuthName "login required" AuthUserFile /opt/http_basic_usernames_and_passwords AuthType Basic Require valid-user Satisfy Any </Directory> This is working fine for HTTP, but failing for HTTPS. My understanding is that in order to inspect the HTTP headers, the SSL handshake must be completed, but apache wants to inspect the <Directory> directives before doing the SSL handshake, even if I place them at the bottom of the configuration file. Q: How could I workaround this issue? PS: I'm not obsessed with the HTTP referer header, I could use other options that would allow users from a known website to bypass authantication.

    Read the article

  • Automated backups for Windows Azure SQL Database

    - by Greg Low
    One of the questions that I've often been asked is about how you can backup databases in Windows Azure SQL Database. What we have had access to was the ability to export a database to a BACPAC. A BACPAC is basically just a zip file that contains a bunch of metadata along with a set of bcp files for each of the tables in the database. Each table in the database is exported one after the other, so this does not produce a transactionally-consistent backup at a specific point in time. To get a transactionally-consistent copy, you need a database that isn't in use.The easiest way to get a database that isn't in use is to use CREATE DATABASE AS COPY OF. This creates a new database as a transactionally-consistent copy of the database that you are copying. You can then use the export options to get a consistent BACPAC created.Previously, I've had to automate this process by myself. Given there was also no SQL Agent in Azure, I used a job in my on-premises SQL Server to do this, using a linked server configuration.Now there's a much simpler way. Windows Azure SQL Database now supports an automated export function. On the Configuration tab for the database, you need to enable the Automated Export function. You can configure how often the operation is performed for you, and which storage account will be used for the backups.It's important to consider the cost impacts of this as well. You are charged for how ever many databases are on your server on a given day. So if you enable a daily backup, you will double your database costs. Do not schedule the backups just before midnight UTC, as that could cause you to have three databases each day instead of one.This is a much needed addition to the capabilities. Scott Guthrie also posted about some other notable changes today, including a preview of a new premium offering for SQL Database. In addition to the Web and Business editions, there will now be a Premium edition that has reserved (rather than shared) resources. You can read about it all in Scott's post here: http://weblogs.asp.net/scottgu/archive/2013/07/23/windows-azure-july-updates-sql-database-traffic-manager-autoscale-virtual-machines.aspx

    Read the article

  • Trouble migrating Joomla from Linux to Windows server

    - by Matt
    I'm having some trouble migrating a Joomla website from a Linux server to a Windows server. The database came over fine, Besides that, all I've done is download all the files from the current site, and change configuration.php so the log and tmp directories show "./tmp/" and "./logs/" I keep having an error in the PHP log stating PHP Fatal error: Class 'JTable' not found I've downloaded the site multiple times now, and I'm convinced this is a configuration problem, and not a missing file problem. I've even tried installing a mod for backup on the linux box to try and migrate the site, but sadly the mod had problems installing. The new server is running IIS 7.5 on Windows Web Server. PHP 5.2.14 and MySQL

    Read the article

  • Discs in DVD Drive not being read

    - by I Heart Ubuntu
    Does anyone have an experience with Ubuntu that is no longer reading discs in the DVD drive? This is my first time Ubuntu does not see the disc :| The disc is fine and works on my other Ubuntu computers. The drive is there and powered. I can even type in eject in a terminal and the drive will open. Using the command: sudo lshw -C disk I am able to see info about my drive too. Actually BOTH of my internal DVD drives cannot read discs anymore. If the output is not readable below, here is the info in pastebin. http://pastebin.com/GqqSCTPw *-cdrom:0 description: DVD writer product: DVD_RW ND-3500AG vendor: _NEC physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom1 logical name: /dev/cdrw1 logical name: /dev/dvd1 logical name: /dev/dvdrw1 logical name: /dev/scd0 logical name: /dev/sr0 version: 2.1B serial: [_NEC DVD_RW ND-3500AG2.1B06022300BT-LIGGY capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD-RAM writer product: CDDVDW SH-S222A vendor: TSSTcorp physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: SB01 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc

    Read the article

  • postfix-dovecot email sending works with squirrel mail but not with Thunderbird?

    - by Mark S.
    I have setup an intranet email system using postfix, dovecot and squirrel mail, Which is working fine, I can send and receive mail to all users on the system. I presume that the issue is in the postfix configuration, because when I configure Thunderbird to send mail I am getting the following error: An error occurred while sending mail. The mail server responded: 4.1.8 <[email protected]>: Sender address rejected: Domain not found. Please check the message recipient [email protected] and try again. Also here is the relevant syslog entries: NOQUEUE: reject: RCPT from host1.intranetdomain.com [More Information] [192.168.11.1 [More Information] ]: 450 4.1.8 <[email protected]>: Sender address rejected: Domain not found; from=<[email protected]> to=<[email protected]> proto=ESMTP helo=<[127.0.0.1 [More Information] ]> I have configured MX records on the DNS server and they respond appropriately when I query them for those MX records, so I do not think that is the issue. I think that my issue is caused by the default configuration of: smtpd_recipient_restrictions = reject_unknown_sender_domain, reject_unknown_recipient_domain, reject_unauth_pipelining, permit_mynetworks, permit_sasl_authenticated, reject_unauth_destination smtpd_sender_restrictions = reject_unknown_sender_domain Since this is on an internal network and it will not be exposed to the internet as a whole which options can I remove safely?

    Read the article

  • Problem with APTonCD application

    - by Harikrishnan
    I created a iso image using aptoncd & burned it to a dvd. Now when i tried to restore, the program does not detect the dvd in the drive. It shows "Please insert a disc in the drive." and if we click "ok" it shows E: Failed to mount the cdrom. The dvd is in the drive itself. I tried sudo lshw -C disk and the output is: *-cdrom description: DVD-RAM writer product: DVDRAM GH22NS50 vendor: HL-DT-ST physical id: 1 bus info: scsi@1:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd0 logical name: /dev/sr0 logical name: /media/APTonCD logical name: /media/apt version: TN02 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 mount.fstype=iso9660 mount.options=ro,relatime,uid=1000,gid=1000,iocharset=utf8,mode=0400,dmode=0500 state=mounted status=ready *-medium physical id: 0 logical name: /dev/cdrom logical name: /media/APTonCD logical name: /media/apt configuration: mount.fstype=iso9660 mount.options=ro,relatime,uid=1000,gid=1000,iocharset=utf8,mode=0400,dmode=0500 state=mounted Then i checked in disk utility application. in that dvd rom is shown as /dvd/sr0 My ubuntu version is 10.10. Please help me to solve the problem.

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • Chassis fans and power LEDs still work in Hibernate

    - by Jaded
    I have ASRock Z68 Extreme3 Gen3 motherboard recently updated to 2.20 BIOS version. OS is Windows 7 x64. The problem is after that update full hibernation (by that i mean full system power off) stopped working although everything was fine before. Now when I press hibernate, sleep in initiated as usual, monitor goes to sleep, HDD and CPU fan stop spinning, but chassis fans (i have Gigabyte Aurora 3D 570 case with two rear and one front fans) still remain working. Also power leds are lit as if computer is turned on. Tried changing different UEFI settings related to sleep mode, and none of them change above described behaviour. I have "Deep Sleep" (Advanced-South Bridge Configuration) set to "Enabled in S4-S5", "Suspend to RAM" (Advanced-ACPI Configuration) set to "Auto", all fans settings in "H/W Monitor" set to "Auto".

    Read the article

  • How to prevent mod_cluster as single point failure?

    - by Hitesh
    In my configuration i used Apche+mod_cluster as a front_end(load balancer) server and two JBOSS AS 7.1.0 as backend server. In my configuration on one system i have install Apache+mod_cluster + JBOSS AS 7.1.0 and on other system JBOSS AS 7.1.0. Both JBOSS AS 7.1.0 are in domain mode means in clustering. My problem is that if Apche+mod_cluster crash than client can not access any JBOSS AS . I want to configure Apache+mod_cluster in Master_Slave format, means if one of Apache+mod_cluter down another Apache+mod_cluster become active and pass client(browser) request to back-end server in normal form without any interruption. Is there any way to make two Apache+mod_cluster to communicate with each other , means to check health status of each other and if any one get down other Apche+mod_cluster will do it's task ......

    Read the article

  • Avoiding double NAT with PPPoA connection

    - by user498429
    I've got an ASUS RT-N56U wending its way to me and have been thinking about how to set this up on my home network. I currently have a Netgear DG634g V5 and was hoping to use this device as a modem only, with everything else being done by the router. Problem is, my ISP uses PPPoA and the asus seems only to support PPPoE. I'm aware that a double NAT configuration should be avoided and I've seen some instructions here: http://www.tomshardware.co.uk/forum/33700-17-ultimate-modem-router-setup-thread Specifically, I was going to follow the guidance in the section entitled "Chaining Two Networks Together In a Cascading Fashion (Modem handles PPPoA)". That seems like it could work. However, is this a double NAT configuration or even a good way to do it? Would UPnP still work? The other option, I understand, is to buy the Draytek Vigor 120 but I'd ideally like to avoid the cost of that if its not necessary.

    Read the article

  • Plesk Backup Best Practices?

    - by The MYYN
    My client utilizes Plesk (9.X) for Server Management. We're implementing a custom backup solution, which should include a complete restorable representation of the actual Plesk configuration (Emails, Domains, etc.). We have full access, since it is a dedicated server resembling these steps: Plesk offers some backups, but they do not include the actual content of the (sub-)domains. Browsing the docs and the internet, I haven't found much ideas on that problem. Our target is to have a disaster recovery scenario: Reinstall a clean OS (Ubuntu) from scratch. Install MySQL/PHP and dependencies (since this runs the app) Install a bare plesk Restore all domains + plesk configuration from an archive Continue operations ... Now steps 1, 2, 3 and 5 are trivial. But what are the best practices for step 4? A side questions: Are there any easy-to-use open source apps out there, to create and restore server-images (even on machines with an possible different hardware)? Thanks for your time and input.

    Read the article

  • phpredis + pconnect

    - by john smith
    I am using phpredis on my php based website. The webserver I am using is a the simplest apache apt-get installation, no configuration involved, as this is only a development environment. The issue I am facing is that basically, while using phpredis, there is no difference between "connect" and "pconnect" commands: they both create a new connection everytime, as I can see from the "info" command on redis-cli. Now, I am pretty sure it is because of the apache configuration and the fact that it probably (most likely) is a multi-threaded env, therefore can't enstablish a single connection. My question is basically for when I will turn into production: what would the best choice of a webserver be to avoid this problem? I remember using lighttpd with thousands of users and still get only a very few (like 2 or 3) connections on mongoDB. Any ideas? Thanks in advance.

    Read the article

  • Missing driver ASUS PCE-N53 11n N600 PCI-E Adapter

    - by oyse
    I have problems with getting an Asus PCE-N53 11n N600 PCI-E Adapter card to work on my desktop computer. As far as I can tell no drivers are installed for the card. I know I can manually download the drivers directly from Asus, but I would rather not go that route. If there are anyone that knows about any packages or other things I can do to make this work would be much appreciated. Some systems details: $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 12.04.1 LTS Release: 12.04 Codename: precise $ sudo lshw -C network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: d4:3d:7e:03:b9:1d size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl8168e-3_0.0.4 03/27/12 ip=192.168.0.173 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:43 ioport:d000(size=256) memory:f2104000-f2104fff memory:f2100000-f2103fff *-network UNCLAIMED description: Network controller product: Ralink corp. vendor: Ralink corp. physical id: 0 bus info: pci@0000:04:00.0 version: 00 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:f7100000-f710ffff $ lsmod Module Size Used by nvidia 12319264 51 vesafb 13844 1 snd_hda_codec_hdmi 32474 1 joydev 17693 0 bnep 18281 2 rfcomm 47604 0 bluetooth 180104 10 bnep,rfcomm snd_hda_codec_realtek 224173 1 snd_seq_midi 13324 0 ppdev 17113 0 snd_rawmidi 30748 1 snd_seq_midi usbhid 47199 0 hid 99559 1 usbhid nouveau 774641 0 parport_pc 32866 1 snd_hda_intel 33773 5 ttm 76949 1 nouveau snd_hda_codec 127706 3 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel drm_kms_helper 46978 1 nouveau drm 242038 3 nouveau,ttm,drm_kms_helper snd_seq_midi_event 14899 1 snd_seq_midi snd_hwdep 13668 1 snd_hda_codec snd_seq 61896 2 snd_seq_midi,snd_seq_midi_event i2c_algo_bit 13423 1 nouveau mxm_wmi 12979 1 nouveau wmi 19256 1 mxm_wmi mac_hid 13253 0 snd_pcm 97188 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec psmouse 97362 0 video 19596 1 nouveau snd_timer 29990 2 snd_seq,snd_pcm snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq snd 78855 20 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_rawmidi,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_seq,snd_pcm,snd_timer,snd_seq_device serio_raw 13211 0 soundcore 15091 1 snd snd_page_alloc 18529 2 snd_hda_intel,snd_pcm mei 41616 0 lp 17799 0 parport 46562 3 ppdev,parport_pc,lp r8169 62099 0

    Read the article

  • Unable to mount an LVM Hard-drive after upgrade

    - by Bruce Staples
    I imagine this is a basic gotcha ... but I can't see it. I have a system with 2(physical) harddrives. The boot system (/dev/sda) was running 10.04 & the second drive (/dev/sdb) was just a mounted filesystem. I did a clean load of Ubuntu 12.04 overwriting /dev/sda (not an upgrade) & now cannot mount the second drive. so I do not know what to enter it into the fstab ... I had expected to use: /dev/sdb /tera ext4 defaults 0 2 But even manual mounting fails (I also have tried various "-t" options on the off chance!) sudo mount -t ext4 /dev/sdb1 /tera mount: wrong fs type, bad option, bad superblock on /dev/sdb1, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so Output from disk queries indicate that it is a Linux LVM & a healthy disk still. sudo lshw -C disk *-disk:0 description: ATA Disk product: WDC WD5000AACS-0 vendor: Western Digital physical id: 0 bus info: scsi@2:0.0.0 logical name: /dev/sda version: 01.0 serial: WD-WCASU1401098 size: 465GiB (500GB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 signature=00015a55 *-disk:1 description: ATA Disk product: WDC WD10EADS-00L vendor: Western Digital physical id: 1 bus info: scsi@3:0.0.0 logical name: /dev/sdb version: 01.0 serial: WD-WCAU47836304 size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 sudo fdisk -l Disk /dev/sda: 500.1 GB, 500106780160 bytes 255 heads, 63 sectors/track, 60801 cylinders, total 976771055 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00015a55 Device Boot Start End Blocks Id System /dev/sda1 * 2048 972580863 486289408 83 Linux /dev/sda2 972582910 976769023 2093057 5 Extended /dev/sda5 972582912 976769023 2093056 82 Linux swap / Solaris Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 1 1953525167 976762583+ 8e Linux LVM LVM doesn't appear to be an option for mount or fstab. ... and here's a Smart data Screenshot from Disk Utility.

    Read the article

  • Is there a way to submit a batch of commands to a Cisco router and have them execute from the router?

    - by atroon
    I need to change the configuration of a remote (6 hours' drive) client's Cisco 871 (IOS 12.4.15T) from my location because of some new internet service at his location. To be more precise, I need to change the default route, ip address of the outside interface (Fa4) and disable the PPPoE setup there. Unfortunately, doing any of this will (obviously) break the connection to the router. I do not have an out-of-band management modem set up (I know, I know). Is there any way to enter the commands I need to have run and have them execute one after the other, from a file on flash:? I have never tried anything like that before. Essentially a DOS-style batch file is exactly what I need. Nothing like it seems to be out there except using kron to execute CLI commands, but that is specified here as only taking EXEC commands, not configuration ones. Is there hope, or do I travel?

    Read the article

  • How to add a permanent redirect (301) for an htm file in IIS 7

    - by bconlon
    Looking in Web Analytics I could see several external sites pointing at an old .htm file on my web server that no longer existed, so I thought I would get IIS to redirect to the new .aspx replacement. How hard could it be? This has annoyed me for quite a while today so here is the answer. 1. Install the Http Redirection module - this is not installed by default!! Windows 7 Start->Control Panel->Programs and Features->Turn Windows Features on or off. Internet Information Services->World Wide Web Services->Common Http Features->HTTP Redirection. Windows Server 2008 Start->Administrative Tools->Server Manager. Roles->Web Server (IIS). Role Services->Add Role Services. Common Http Features->HTTP Redirection. 2. Edit your web.config file <configuration>     .....     <location path="oldfile.htm">         <system.webServer>             <httpRedirect enabled="true" destination="/newfile.aspx" exactDestination="true" childOnly="true" httpResponseStatus="Permanent" />         </system.webServer>     </location>     ..... </configuration> When a user clicks or Google crawls ‘oldfile.htm’ it will get a permanent redirect to ‘/newfile.aspx’ - and should take any Page Rank to the new file.  #

    Read the article

  • I just got a linode VPS a week ago and I've been flagged for SSH scanning...

    - by meder
    I got a 32-bit Debian VPS from http://linode.com and I really haven't done any sort of advanced configuration for securing it ( port 22; password enabled ). It seems somehow there is ssh scanning going on from my IP, I'm being flagged as this is against the TOS. I've been SSHing only from my home Comcast ISP which I run Linux on. Is this a common thing when getting a new vps? Are there any standard security configuration tips? I'm quite confused as to how my machine has been accused of this ssh scanning.

    Read the article

  • Best way to replicate servers

    - by Matthew
    I currently have two servers both with linux software RAID1 configurations. They use heartbeat and DRBD to create a shared DRBD device that hosts a a exported NFS directory. The servers run Ubuntu Server with a LXDE GUI and some IP These servers are going to be placed on fishing vessels to act has redundant storage for IP cameras. My boss wants me to figure out the most efficient way to create these servers. We might be looking at pushing out several systems a week. Each configuration will be almost identical besides IP addressing. What would be the best method to automate the configuration process? We are trying to cut down on labor costs to set these up. Imaging and Proceeding are both on my mind right now