Search Results

Search found 21884 results on 876 pages for 'external address'.

Page 174/876 | < Previous Page | 170 171 172 173 174 175 176 177 178 179 180 181  | Next Page >

  • Issue with multiple bridging for KVM hosts

    - by Henry-Nicolas Tourneur
    I'm using KVM and libvirt on my host (Debian lenny) + 2 bridges per guest (one for mgmt, one for public traffic). That setup isn't stable at all, sometimes I can do pings to a management ip, sometimes not. I don't know if my bridging paramateres are correct, could you check ? or if there is anything wrong ... Please also note that interface on guest doesn't flap and that I got not logs on my host. Of course forwarding is enabled. iface eth3 inet manual auto bond0 iface bond0 inet manual slaves eth1 eth2 pre-up ip link set bond0 up down ip link set bond0 down auto br0 iface br0 inet static address 10.160.0.7 netmask 255.255.255.128 bridge_ports eth3 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off auto br0:1 iface br0:1 inet static address 10.160.0.9 netmask 255.255.255.128 auto br0:2 iface br0:2 inet static address 10.160.0.10 netmask 255.255.255.128 auto br1 iface br1 inet static address 217.4.40.242 netmask 255.255.255.240 gateway 217.4.40.241 pre-up /etc/network/firewall start bridge_ports bond0 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off auto br1:1 iface br1:1 inet static address 217.4.40.252 netmask 255.255.255.240 auto br1:2 iface br1:2 inet static address 217.4.40.253 netmask 255.255.255.240

    Read the article

  • Dell Latitude E6420 dual-boot Ubuntu + Windows 7 Optimus graphics problems

    - by Ryan
    I have a Dell Latitude E6420 laptop with Ubuntu 12.04 alongside Windows 7 (dual-boot) docked in a docking station with 2 DVI outputs. It took me a week of tinkering to get the dual external monitors to work in Ubuntu, and I had to disabled the "Optimus" feature in the BIOS. But now neither external monitor is detected in Windows, and the resolution is also very low. Do you know how I can successfully dual-boot Windows 7 and Ubuntu on this machine using my 2 external DVI monitors? I have an open question here too, trying to resolve this same issue: http://askubuntu.com/questions/146933/dock-with-dual-external-dvi-monitors-with-intel-nvidia-optimus

    Read the article

  • How can I check whether a volume is mounted where it is supposed to be using Python?

    - by Ben Hymers
    I've got a backup script written in Python which creates the destination directory before copying the source directory to it. I've configured it to use /external-backup as the destination, which is where I mount an external hard drive. I just ran the script without the hard drive being turned on (or being mounted) and found that it was working as normal, albeit making a backup on the internal hard drive, which has nowhere near enough space to back itself up. My question is: how can I check whether the volume is mounted in the right place before writing to it? If I can detect that /external-backup isn't mounted, I can prevent writing to it. The bonus question is why was this allowed, when the OS knows that directory is supposed to live on another device, and what would happen to the data (on the internal hard drive) should I later mount that device (the external hard drive)? Clearly there can't be two copies on different devices at the same path! Thanks in advance!

    Read the article

  • How is it possible that I can do a host lookup but not a curl?

    - by Daniel Quinn
    Has anyone ever seen this before? Note that this happens not only with google.com, but with every domain I try. It's a wireless connection (WEP), but I'm not sure how that would be relevant: $ curl -v google.com # This takes about 60s to return * getaddrinfo(3) failed for google.com:80 * Couldn't resolve host 'google.com' * Closing connection #0 curl: (6) Couldn't resolve host 'google.com' $ host google.com google.com has address 209.85.148.106 google.com has address 209.85.148.147 google.com has address 209.85.148.99 google.com has address 209.85.148.103 google.com has address 209.85.148.104 google.com has address 209.85.148.105 google.com mail is handled by 30 alt2.aspmx.l.google.com. google.com mail is handled by 40 alt3.aspmx.l.google.com. google.com mail is handled by 50 alt4.aspmx.l.google.com. google.com mail is handled by 10 aspmx.l.google.com. google.com mail is handled by 20 alt1.aspmx.l.google.com. $ cat /etc/resolv.conf # Generated by NetworkManager nameserver 192.168.1.201 $ cat /etc/hosts 127.0.0.1 localhost ::1 localhost $ netstat -rn Kernel IP routing table Destination Gateway Genmask Flags MSS Window irtt Iface 0.0.0.0 192.168.1.254 0.0.0.0 UG 0 0 0 wlan0 127.0.0.0 127.0.0.1 255.0.0.0 UG 0 0 0 lo 192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 wlan0

    Read the article

  • Laptop VGA Output Stopped Working

    - by Jack7890
    I regularly use an external monitor with my laptop. Today, when I booted up, the external monitor refused to work--it just keeps going into power save mode. I tried a different external monitor and had the same problem, so it must be a problem with the laptop itself. Things I've tried: Going into the Display Settings via the Control Panel (I'm running Vista) and attaching/unattaching/reattaching the external monitor. Turning the computer off, unplugging, plugging it back in, and rebooting Blowing into the VGA out to get rid of any dust Toggling through the Fn+F7 options I'm thinking maybe this is an issue with my video card? If necessary, I'm comfortable opening up my laptop and playing around with things, but I'm not sure what to look for. Does anyone have any suggestions?

    Read the article

  • Laptop VGA Out Stopped Working

    - by Jack7890
    I regularly use an external monitor with my laptop. Today, when I booted up, the external monitor refused to work--it just keeps going into power save mode. I tried a different external monitor and had the same problem, so it must be a problem with the laptop itself. Things I've tried: Going into the Display Settings via the Control Panel (I'm running Vista) and attaching/unattaching/reattaching the external monitor. Turning the computer off, unplugging, plugging it back in, and rebooting Blowing into the VGA out to get rid of any dust Toggling through the Fn+F7 options I'm thinking maybe this is an issue with my video card? If necessary, I'm comfortable opening up my laptop and playing around with things, but I'm not sure what to look for. Does anyone have any suggestions?

    Read the article

  • Preventing 'Reply-All' to Exchange Distribution Groups

    - by Larold
    This is another question in a short series regarding a challenging Exchange project my co-workers have been asked to implement. (I'm helping even though I'm primarily a Unix guy because I volunteered to learn powershell and implement as much of the project in code as I could.) Background: We have been asked to create many distribution groups, say about 500+. These groups will contain two types of members. (Apologies if I get these terms wrong.) One type will be internal AD users, and the other type will be external users that I create Mail Contact entries for. We have been asked to make it so that a "Reply All" is not possible to any messages sent to these groups. I don't believe that is 100% possible to enforce for the following reasons. My question is - is my following reasoning sound? If not, please feel free to educate me on if / how things can properly be implemeneted. Thanks! My reasoning on why it's impossible to prevent 100% of potential reply-all actions: An interal AD user could put the DL in their To: field. They then click the '+' to expand the group. The group contains two external mail contacts. The message is sent to everyone, including those external contacts. External user #1 decides to reply-all, and his mail goes to, at least, external user #2, which wouldn't even involve our Exchange mail relays. An internal AD user could place the DL in their Outlook To: field, then click the '+' button to expand the DL. They then fire off an email to everyone that was in the group. (But the individual addresses are listed in the 'To:' field.) Because we now have a message sent to multiple recipients in the To: field, the addresses have been "exposed", and anyone is free to reply-all, and the messages just get sent to everyone in the To: field. Even if we try to set a Reply-To: field for all of these DLs, external mail clients are not obligated to abide by it, or force users to abide by it. Are my two points above valid? (I admit, they are somewhat similar.) Am I correct to tell our leadership "It is not possible to prevent 100% of the cases where someone will want to Reply-All to these groups UNLESS we train the users sending emails to these groups that the Bcc: field is to be used at all times." I am dying for any insight or parts of the equation I'm not seeing clearly. Thank you!!!

    Read the article

  • How to make a persistent acknowledgment in Icinga/Nagios?

    - by blerontin
    I am using Icinga (Nagios fork) to also monitor uptime of external hosts and services. Currently when looking at the "Critical" count I find it difficult to decide if an internal service is affected (I should take immediate action) or an external service (I just acknowledge the problem). Is there a way to keep a problem acknowledgement for future down-times of the checked host/service? Is there some way to auto-acknowledge the state change of external hosts/services?

    Read the article

  • Configuring Windows Server Backup Destination Drive Sets

    - by Nicholas
    Is it possible to set up the standard backup system in SBS 2011 (or Server 2008 R2) to use an internal drive as a destination as well as external drives? Before you say yes, from my tests and from what I've read on the web, backups with internal drives included as a destination always seems to prefer the internal drive over connected external ones. (Regardless of what drive might be marked as 'active'). So no data ever gets written to a plugged in external drive. In my opinion external drives should always have priority over internal drives or including them is pointless.

    Read the article

  • Separate brightness/power-saving settings for multiple monitors

    - by MariusMatutiae
    At home, I connect my laptop to an external monitor. Under Linux X server, it works perfectly. Occasionally I watch a movie on the external monitor. When I do, I would like to fold the laptop shut, and just relax. This however triggers my settings for dimming the screen after 10 minutes of inactivity, which in turn extends to the external monitor. I know I could solve the problem by setting dimming to "Never", but this is a waste, causes the laptop to overheat, and is bad for the normal laptop use. How can I set the power saving/brightness specs for the external monitor, independently of the onboard one? I run Debian or Arch, under KDE.

    Read the article

  • Assign individual NIC to KVM guest

    - by Bin S
    I have a server with 6 NICs installed and is running Ubuntu 12.04LTS. I want to setup 4 guest VMs using kvm. Now I want to assign 2 NICs for the host(1 Public IP and 1 private IP), and 1 NIC each to 4 guest VM(all private IP). How do I do this? /etc/network/interfaces I am having trouble with my configuration file shown below: # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet static address 192.168.1.109 netmask 255.255.255.0 gateway 192.168.1.5 auto eth1 iface eth1 inet static address 192.168.1.117 netmask 255.255.255.0 auto eth2 iface eth2 inet manual auto br0 iface br0 inet static address 192.168.1.118 netmask 255.255.255.0 bridge_ports eth2 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off auto eth3 iface eth3 inet manual auto br1 iface br1 inet static address 192.168.1.119 netmask 255.255.255.0 bridge_ports eth3 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off auto eth4 iface eth4 inet manual auto br2 iface br2 inet static address 192.168.1.123 netmask 255.255.255.0 bridge_ports eth4 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off auto eth5 iface eth5 inet manual auto br3 iface br3 inet static address 192.168.1.124 netmask 255.255.255.0 bridge_ports eth5 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off

    Read the article

  • Virtual PC 2007 Full Screen Resolution

    - by Swami
    I have a laptop (1440 x 900) and an external monitor (1920 x 1200), and I'm running Virtual PC 2007. Initially, my VPC could not switch to fullscreen mode on my external monitor because the max resolution for VPC was only 1600 x 1200. I installed a hotfix (http://support.microsoft.com/kb/958162) and after the hotfix, I was able to view VPC in fullscreen mode on my external monitor, but now I'm unable to view fullscreen on my laptop. It says "please check that the resolution of the guest is not higher than that of the host". I even tried to decrease the resolution of my Virtual PC to less than than of my laptop, but it always resets it back up. So now after the hotfix, I can view fullscreen mode only when my external monitor is plugged in. Any way I can resolve this?

    Read the article

  • Windows 7 using llt for ipv6

    - by Seoman
    The question asked below is based on the specific implementations of the Os not the RFC. Looking on a way to be able to assign a fixed ip address to a host, before it boots I found that Centos 6 works fine with no modifications and Windows 7 does not work at all. As defined in enter link description here exists 3 valid ways of generate a DUID: 1 Link-layer address plus time 2 Vendor-assigned unique ID based on Enterprise Number 3 Link-layer address Looking at the centos, that works fine, I can see the following autogenerated DUID: option dhcp6.client-id 0:1:0:1:19:60:25:f1:52:54:0:6b:b9:9e; and the MAC address for this host is: ifconfig eth1 | grep HWaddr eth1 Link encap:Ethernet HWaddr 52:54:00:6B:B9:9E As you can see, the DUID containts the MAC address. I can assign a fixed ip address to this host by including an entry on my dhcp server similar to: host vm { hardware ethernet 52:54:00:6B:B9:9E; fixed-address6 2001:db8:0:1::200; if packet(0,1) = 1 { log(debug,"VM Request match!"); } } And the Centos 6 gets his ip. On the windows side, I faced a common problem explained on this other link enter link description here As summary, Win7 uses the option 2 of the DUID generation or a variation of this one. On the link explains how to move it to a llt (link layer + time) but is not working fine. If I modify the DUID to one that looks like the one generated on Centos (but with the right MAC) it works as expected. Question 1 How Can I change the DUID generation for Windows 7 to be based on MAC as Centos 6 does? Thanks

    Read the article

  • Mac OS X - Time Machine backup fails verification - What can I do to save the history?

    - by usermac75
    Hi, How do I make Time Machine to make a new complete backup without losing older versions of backed up files? Verbose: I am using the Time Machine backup on my OS X (Snow Leopard) to backup the whole computer to an external drive. I especially like the "history", i.e. the feature that allows you to restore the older version of a file. Problem: I had some data corruption on my external backup drive, I repaired it with the System Tool for doing that, it found some faults. I had the disk tool repair the external drive. After that, the external drive was OK and I could use Time Machine again. I let Time Machine do one more backup. Now I made a verification according to http://superuser.com/questions/47628/verifying-time-machine-backups, namely along sudo diff -qr . $HOME/Desktop 2>&1 | tee $HOME/timemachine-diff.log However: After doing the command above, several differences and missing files were reported, approx. 200 files in sum. Whereas some of the missing files were cache or excluded directories, the differences do bother me, especially as some important documents from me are listed as differing. How can I make sure that the data on the external drive is synced correctly? Is it possible to have Time Machine to do a complete new backup without losing the history? Or to have Time Machine compare all files for differences and re-write all files that are different? Or can I set some flags on the files that do not match to have them copied again? (like the archive-flag in Windows/Dos). I'd rather not touch the files because I would like to keep the date of last change/date of creation) Thank you for your thoughts!

    Read the article

  • NDR for meeting requests

    - by Adam
    We've got a mailbox for each department (e.g [email protected] and [email protected]) and everyone in that department has access to it, access is granted using Exchange Management Console. If I send a calendar invite to [email protected], I get a Undeliverable report: Delivery has failed to these recipients or groups: User_A The e-mail address you entered couldn't be found. Check the address and try resending the message. If the problem continues, please contact your helpdesk. User_B The e-mail address you entered couldn't be found. Check the address and try resending the message. If the problem continues, please contact your helpdesk. User_C The e-mail address you entered couldn't be found. Check the address and try resending the message. If the problem continues, please contact your helpdesk. The users are no longer in AD or Exchange but we cannot find any mention of them within any deligates or permissions anywhere. We only started to get this problem AFTER we upgraded our DCs from Windows Server 2003 to Windows Server 2008 and Exchange server from Windows Server 2003, with Exchange 2005 to Windows Server 2008, with exchange 2010.

    Read the article

  • Cross domain LDAP

    - by Adam
    For a system we are developing we have 2 domains an internal and an external domain with bi directional trust between them. However the servers are only able to connect to their own DC's. We have an application server on the internal domain which needs to use an LDAP query to gather a list of users from a group on the external domain. How do i go about writing an LDAP query that asks one DC to go ask another DC for a list of users. I tried querying the internal DC with the same LDAP query I would use if it could hit the external DC directly but this does not work. When i use Softerra LDAP Administraor I can view the full hierarchy of the interal domain but despite the trust relationship between domains i am unable to see any of the external doamin. Any suggestions or help would be greatly appreciated

    Read the article

  • What software this log file comes from? [closed]

    - by mickula
    From what software comes this logfile? Please specify full name. Internal IP Threshold FlowsDiff 40 flows/s, Diff: 73 flows/s Sum 26.962 flows/300s (89 flows/s), 32.162.000 packets/300s (107.206 packets/s), 1,198 GByte/300s (32 MBit/s) External 87.98.238.221, 26.958 flows/300s (89 flows/s), 32.156.000 packets/300s (107.186 packets/s), 1,198 GByte/300s (32 MBit/s) External 89.230.69.49, 2 flows/300s (0 flows/s), 2.000 packets/300s (6 packets/s), 0,000 GByte/300s (0 MBit/s) External 89.231.190.149, 1 flows/300s (0 flows/s), 3.000 packets/300s (10 packets/s), 0,000 GByte/300s (0 MBit/s) External 89.239.101.20, 1 flows/300s (0 flows/s), 1.000 packets/300s (3 packets/s), 0,000 GByte/300s (0 MBit/s)

    Read the article

  • Duplication of Windows 7 Backup

    - by Steven Pickles
    I use the built in backup utility for Windows 7 because it's automated and flexible enough to allow me to schedule a daily shadow copy backup of particular files and folders directly to a separate internal RAID 0 array (2 x 1TB). It's also lightweight and stays out of the way. For off-site backup purposes, each week I copy the contents of the internal backup from the RAID 0 array to an external 1 TB drive. I then store move this drive to a different building. The copy from the internal backup to the external backup typically works like this: mount and erase contents of external drive highlight "file" on internal drive, hit CTRL+C CTRL+V on root directory of external drive Is there a better way to synchronize? Microsoft's SyncToy application does a pitiful job, and often leaves the folders not truly synchronized... which completely defeats the ability to use the backup's restore feature.

    Read the article

  • Open ports broken from internal network

    - by ksvi
    Quick summary: Forwarded port works from the outside world, but from the internal network using the external IP the connection is refused. This is a simplified situation to make the explanation easier: I have a computer that is running a service on port 12345. This computer has an internal IP 192.168.1.100 and is connected directly to a modem/router which has internal IP 192.168.1.1 and external (public, static) IP 1.2.3.4. (The router is TP-LINK TD-w8960N) I have set up port forwarding (virtual server) at port 12345 to go to port 12345 at 192.168.1.100. If I run telnet 192.168.1.100 12345 from the same computer everything works. But running telnet 1.2.3.4 12345 says connection refused. If I do this on another computer (on the same internal network, connected to the router) the same thing happens. This would seem like the port forwarding is not working. However... If I run a online port checking service on my external IP and the service port it says the port is open and I can see the remote server connecting and immediately closing connection. And using another computer that is connected to the internet using a mobile connection I can also use telnet 1.2.3.4 12345 and I get a working connection. So the port forwarding seems to be working, however using external IP from the internal network doesn't. I have no idea what can be causing this, since another setup very much like this (different router) works for me. I can access a service running on a server from inside the network both through the internal and external IP.

    Read the article

  • ubuntu server refusing connections via port forwarding

    - by Matt
    Getting some really weird behavior from our Ubuntu server... it's behind a Verizon router firewall with port forwarding (port 8080 to port 80 on the server), and we've been having issues accessing it via this external IP. From within the network, it appears to respond normally (I can access it via web browser and SSH), but refuses connections through port forwarding (using our static external IP). The strangest thing is that it actually responds to external port-forwarded connections right after being restarted, but quickly lapses back into this pattern of refusing external connections. I'm a bit of a server newbie (I'm actually a programmer in a small startup that just lost their server ops guy, urgh) so this is all trial by fire for me. Does anyone have any advice on what could be going wrong here? Any help would be appreciated, thanks.

    Read the article

  • How does the internet protocol handle network card numbers?

    - by Giorgio
    I know that data packets sent over the internet carry the source and destination IP address, so that the protocol can route the data to the correct destination and keep track of the source address of the packet. But what about the network card address? As far as I know, each network card has a unique identification number. Is this also transmitted with a TCP/IP packet? And when a packet is received at its destination, how is the IP address mapped to a network card number? In other words. On the sender part: does the sender store the sender network card number in the IP packets that it is sending? On the receiver part: which component maps the IP address to the receiver's network card number when a packet is received? E.g., in a home network, does the modem / router map the destination IP address of an incoming packet to a network card number and deliver the packet directly to that network card? A link to documentation on these topics would be of great help.

    Read the article

< Previous Page | 170 171 172 173 174 175 176 177 178 179 180 181  | Next Page >