  • Mac OS X - Time Machine backup fails verification - What can I do to save the history?

    - by usermac75
    Hi, How do I make Time Machine to make a new complete backup without losing older versions of backed up files? Verbose: I am using the Time Machine backup on my OS X (Snow Leopard) to backup the whole computer to an external drive. I especially like the "history", i.e. the feature that allows you to restore the older version of a file. Problem: I had some data corruption on my external backup drive, I repaired it with the System Tool for doing that, it found some faults. I had the disk tool repair the external drive. After that, the external drive was OK and I could use Time Machine again. I let Time Machine do one more backup. Now I made a verification according to http://superuser.com/questions/47628/verifying-time-machine-backups, namely along sudo diff -qr . $HOME/Desktop 2>&1 | tee $HOME/timemachine-diff.log However: After doing the command above, several differences and missing files were reported, approx. 200 files in sum. Whereas some of the missing files were cache or excluded directories, the differences do bother me, especially as some important documents from me are listed as differing. How can I make sure that the data on the external drive is synced correctly? Is it possible to have Time Machine to do a complete new backup without losing the history? Or to have Time Machine compare all files for differences and re-write all files that are different? Or can I set some flags on the files that do not match to have them copied again? (like the archive-flag in Windows/Dos). I'd rather not touch the files because I would like to keep the date of last change/date of creation) Thank you for your thoughts!

    Read the article

  • Formatting a former RAID 0 drive through USB

    - by EXC
    I'll try to be as specific as possible here: I was using two Hitachi 2.5" 500 gb HDDs in my Gateway P-7805u laptop in a RAID 0 configuration. The array was causing the laptop to run extremely hot, however, so I removed them and deleted the RAID array through Intel Matrix HDD manager. I did a clean install of Windows 7 on the original 320 gb HDD that came with the laptop. I never did format the original RAID array HDDs before taking them out of the computer. Now, I am attempting to format the Hitachi 500 gb RAID array HDDs externally through a USB external enclosure. The external HDD drivers install on my clean install OS, but when I go into 'My Computer' there is no external drive available. I cannot format in CMD Prompt because my computer will not designate a drive letter to the external HDD. The drivers install and the HDD is recognized as a Hitachi external drive, but nothing seems to show up in my computer window. I need to know if there is a way to format these drives to NTFS externally.

    Read the article

  • Fixed or consistent mount location for a USB hard drive

    - by Journeyman Geek
    I store my music on an external hard drive, and play them with foobar2k. However, the drive letter changes, which usually means I need to rebuild a fairly large playlist every so often. I'm wondering if there's a way to reserve a drive letter for a specific external device (or type of device) by device ID or volume name, or if I'm better off using a NTFS mount point, and re-mounting the drive to a folder each time. I'm using either a Windows XP or 7 system, and the external drive is NTFS.

    Read the article

  • Grub File Stolen ( WINDOWS and OpenSus )

    - by NESIRSUSEJ
    I have a problem with my computer. I installed OpenSus on my external, and I still have Windows on my HDD. OpenSus took the Grub file and placed it on my external, so now I have to open OpenSus to open Windows. I never got a Windows CD when I bought my computer ( I live in South Africa :) ).... I want to install Ubuntu 12.04 on my external, but then I will have to format my external in which case I will lose the Grub file causing me to lose Windows, which I can't afford to do... yet. Does anyone have an idea what I can do?

    Read the article

  • taglib link errors

    - by Vihaan Verma
    I m using taglib for one of my projects . The Debug/Release library is build using MSVC 10. On compiling the code with the library in taglib/taglib/Release some linker error are thrown . id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: class TagLib::AudioPropertie s * __cdecl TagLib::FileRef::audioProperties(void)const " (__imp_?audioProperties@FileRef@TagLib@@QEBAPEAVAudioProp erties@2@XZ) referenced in function "struct MetaData __cdecl ID3::getMetaDataOfFile(class std::basic_string<char,st ruct std::char_traits<char>,class std::allocator<char> >)" (?getMetaDataOfFile@ID3@@YA?AUMetaData@@V?$basic_string@ DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: virtual __cdecl TagLib::Stri ng::~String(void)" (__imp_??1String@TagLib@@UEAA@XZ) referenced in function "struct MetaData __cdecl ID3::getMetaDa taOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >)" (?getMetaDataOfF ile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: class std::basic_string<char ,struct std::char_traits<char>,class std::allocator<char> > __cdecl TagLib::String::to8Bit(bool)const " (__imp_?to8 Bit@String@TagLib@@QEBA?AV?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@_N@Z) referenced in function "struct MetaData __cdecl ID3::getMetaDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class s td::allocator<char> >)" (?getMetaDataOfFile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator @D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: virtual __cdecl TagLib::File Ref::~FileRef(void)" (__imp_??1FileRef@TagLib@@UEAA@XZ) referenced in function "struct MetaData __cdecl ID3::getMet aDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >)" (?getMetaData OfFile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: class TagLib::Tag * __cdecl TagLib::FileRef::tag(void)const " (__imp_?tag@FileRef@TagLib@@QEBAPEAVTag@2@XZ) referenced in function "struct Meta Data __cdecl ID3::getMetaDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator <char> >)" (?getMetaDataOfFile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z ) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: bool __cdecl TagLib::FileRef ::isNull(void)const " (__imp_?isNull@FileRef@TagLib@@QEBA_NXZ) referenced in function "struct MetaData __cdecl ID3: :getMetaDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >)" (?getM etaDataOfFile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: __cdecl TagLib::FileRef::Fil eRef(class TagLib::FileName,bool,enum TagLib::AudioProperties::ReadStyle)" (__imp_??0FileRef@TagLib@@QEAA@VFileName @1@_NW4ReadStyle@AudioProperties@1@@Z) referenced in function "struct MetaData __cdecl ID3::getMetaDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >)" (?getMetaDataOfFile@ID3@@YA?AU MetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) id3.cpp.1.o : error LNK2019: unresolved external symbol "__declspec(dllimport) public: __cdecl TagLib::FileName::Fi leName(char const *)" (__imp_??0FileName@TagLib@@QEAA@PEBD@Z) referenced in function "struct MetaData __cdecl ID3:: getMetaDataOfFile(class std::basic_string<char,struct std::char_traits<char>,class std::allocator<char> >)" (?getMe taDataOfFile@ID3@@YA?AUMetaData@@V?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@@Z) I m only including tag.lib from taglib/taglib/Release folder . Is there some other library I m missing out?

    Read the article

  • GPLv2 - Multiple AI chess engines to bypass GPL

    - by Dogbert
    I have gone through a number of GPL-related questions, the most recent being this one: http://stackoverflow.com/questions/3248823/legal-question-about-the-gpl-license-net-dlls/3249001#3249001 I'm trying to see how this would work, so bear with me. I have a simple GUI interface for a game of Chess. It essentially can send/receive commands to/from an external chess engine (ie: Tong, Fruit, etc). The application/GUI is similar in nature to XBoard ( http://www.gnu.org/software/xboard/ ), but was independently designed. After going through a number of threads on this topic, it seems that the FSF considers dynamically linking against a GPLv2 library as a derivative work, and that by doing so, the GPLv2 extends to my proprietary code, and I must release the source to my entire project. Other legal precedents indicate the opposite, and that dynamic linking doesn't cause the "viral" effect of the GPL to propagate to my proprietary code. Since there is no official consensus that can give a "hard-and-fast" answer to the dynamic linking question, would this be an acceptable alternative: I build my chess GUI so that it sends/receives the chess engine AI logic as text commands from an external interface library that I write The interface library I wrote itself is then released under the GPL The interface library is only used to communicate via a generic text pipe to external command-line chess engines The chess engine itself would be built as a command-line utility rather than as a library of any sort, and just sends strings in the Universal Chess Interface of Chess Engine Communication Protocol ( http://en.wikipedia.org/wiki/Chess_Engine_Communication_Protocol ) format. The one "gotcha" is that the interface library should not be specific to one single GPL'ed chess engine, otherwise the entire GUI would be "entirely dependent" on it. So, I just make my interface library so that it is able to connect to any command-line chess engine that uses a specific format, rather than just one unique engine. I could then include pre-built command-line-app versions of any of the chess engines I'm using. Would that sort of approach allow me to do the following: NOT release the source for my UI Release the source of the interface library I built (if necessary) Use one or more chess engines and bundle them as external command-line utilities that ship with a binary version of my UI Thank you.

    Read the article

  • Can't install Ubuntu on Asus Eee 1015pem

    - by Peter
    I'm having trouble to install Ubuntu. I use a ASUS Eee 1015pem netbook. Recently, I my netbook got wet. I had it inside my backback and all my things got wet. The netbook boots up fine but it will not load the OS. I downloaded ubuntu onto my external hard drive and changed the settings in my Bios to boot from a removable device. Nothing happens. When I plug in my external hard drive I'm not able to get to the boot icon. I have to unplug it the external hard drive. Set my boot settings I tried both Removable and CD-Rom. Than I plug my external drive back in and nothing happens on either settings. My Asus never came with a recovery disk and suppose to have a build in recovery by pressing F9 in the Bios. Also I need to disable Boot Booster in Bios and Boot Booster is not even an opition in Bios. My friend told me try installing Ubuntu but now I'm having no luck with Ubuntu. Any suggestions?

    Read the article

  • How can I make multiple displays work on my Asus UX32VD?

    - by oKtosiTe
    Original title: Why do I have two trash icons in the Unity Launcher? Whether I run Ubuntu as a live-USB or install it, I always have two trash bins on the Unity Launcher. Both work, and both open the same location. This seems a bit redundant; what could be done about it? Update: Turning auto-hide on made it obvious that I have multiple Launchers showing. With auto-hide off, they simply overlap, making it look like there's a double trash icon, but with auto-hide enabled, I can display one Launcher (and therefore one trash icon) at a time. Still, two are running simultaneously. Second update: This problem appears to be caused by the way Ubuntu handles multiple displays on my Asus UX32VD Ultrabook. Somehow, the laptop display cannot be used while my external display is connected. It is shown in the Displays list, but remains black no matter how I configure it. The external display runs at 1920x1200, the laptop monitor should run at 1920x1080. It therefore becomes obvious that the Launcher that's supposed to run on the laptop display, is actually displayed on the external monitor. Using nomodeset as a kernel parameter as indicated here makes the laptop display inaccessible altogether, detecting the external monitor as the laptop display and making resolutions other than 1920x1200 inaccessible. That is not an option.

    Read the article

  • Depending on fixed version of a library and ignore its updates

    - by Moataz Elmasry
    I was talking to a technical boss yesterday. Its about a project in C++ that depends on opencv and he wanted to include a specific opencv version into the svn and keep using this version ignoring any updates which I disagreed with.We had a heated discussion about that. His arguments: Everything has to be delivered into one package and we can't ask the client to install external libraries. We depend on a fixed version so that new updates of opencv won't screw our code. We can't guarantee that within a version update, ex from 3.2.buildx to 3.2.buildy. Buildy the function signatures won't change. My arguments: True everything has to be delivered to the client as one package,but that's what build scripts are for. They download the external libraries and create a bundle. Within updates of the same version 3.2.buildx to 3.2.buildy its impossible that a signature change, unless it is a really crappy framework, which isn't the case with opencv. We deprive ourselves from new updates and features of that library. If there's a bug in the version we took, and even if there's a bug fix later, we won't be able to get that fix. Its simply ineffiecient and anti design to depend on a certain version/build of an external library as it makes our project difficult in the future to adopt to new changes. So I'd like to know what you guys think. Does it really make sense to include a specific version of external library in our svn and keep using it ignoring all updates?

    Read the article

  • Automatic switching between monitor configurations

    - by Michael Aquilina
    I have a laptop and an external monitor and i was wondering if there was a simple approach to switching between multiple monitor configurations based on the detected available displays. For example: When i am at home and i plug in my external monitor i would like this to automatically become enabled and the laptop screen to become disabled. As soon as i pull out the display cable for the external monitor, i would like the laptop screen to automatically become enabled. I was expecting this to just "work" just like it does in windows - but it seems to be much harder than that. I am aware of the xrandr command to turn displays on and off but i cannot seem to find a way to get this to work the way i describe above. I had also found this post about switching between multiple monitor configurations and the results seem a bit inconclusive. However i was hoping that with xrandr there would be a simpler solution. For me, the fact that when i pull out my external monitor the screen just goes black and i get an error message is a big issue holding me back from making the complete switch to linux as i move around alot as a student. My OS of choice is currently Kubuntu 12.04 but i am willing to change to something else if it provides a better way of setting up the described setup.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • DHCP "no answer" on CentOS 6.4

    - by Kev
    I installed a DHCP server (yum install dhcp) and this is my conf: # create new # specify domain name option domain-name "mydomain.name"; # specify DNS's hostname or IP address option domain-name-servers 10.0.1.1, 10.0.1.2; option ntp-servers 10.0.1.1, 10.0.1.2; allow unknown-clients; # default lease time default-lease-time 2628000; # max lease time max-lease-time 2628000; # about a month # this DHCP server to be declared valid authoritative; # specify network address and subnet mask subnet 10.0.0.0 netmask 255.0.0.0 { # specify the range of lease IP address range dynamic-bootp 10.0.2.1 10.0.2.50; # specify broadcast address option broadcast-address 10.255.255.255; # specify default gateway option routers 10.0.0.1; allow unknown-clients; } service dhcp start reports [ OK ]. Yet, if I disable my other DHCP server (Win2k3) and get a client to try renewing its IP lease, it times out. So I installed dhcping. No matter what options I try, including directing dhcping at my server, adding a client address in the range, adding my hardware address, it replies 'no answer'. I'm also trying -i since that seems to be more akin to what a WinXP client would try to do, based on /var/log/messages. It logs the attempts (from dhcping here) as: Oct 24 18:55:13 newdc dhcpd: DHCPINFORM from 10.0.2.15 via eth0:4 Oct 24 18:55:13 newdc dhcpd: DHCPACK to 10.0.2.15 (00:11:25:66:4e:7f) via eth0:4 Oct 24 18:55:13 newdc dhcpd: DHCPINFORM from 10.0.2.15 via eth0:3 Oct 24 18:55:13 newdc dhcpd: DHCPACK to 10.0.2.15 (00:11:25:66:4e:7f) via eth0:3 Oct 24 18:55:13 newdc dhcpd: DHCPINFORM from 10.0.2.15 via eth0 Oct 24 18:55:13 newdc dhcpd: DHCPACK to 10.0.2.15 (00:11:25:66:4e:7f) via eth0 The :3 and :4 are because I have a few extra Host(A) records for this server so it responds on more than one IP for our intranet app. No answer? It sounds like it should be getting three answers...no? (And if that's the problem, how do I limit the DHCP service to replying from eth0?)

    Read the article

  • Virtual Network Interface and NAT disables localhost access for MySQL and Apache

    - by Interarticle
    I'm running an Ubuntu Server 12.04, and recently I configured it to do NAT for my laptop. Since the server has only one NIC, I followed instructions online to create a virtual network device (eth0:0) that has a LAN IP address, then further configured iptables and UFW to allow internet sharing. However, just a few days ago, I discovered that one of the PHP pages hosted on the server failed for no apparent reason. A little digging revealed that the MySQL server started refusing connections from localhost. The same happened with a page (PhpMyAdmin) that was configured to be accessible only from localhost (in Apache2). The error, as shown by $mysql --protocol=tcp -u root -p looks like ERROR 1130 (HY000): Host '<host name of eth0>' is not allowed to connect to this MySQL server However, the funny thing is, I configured the mysql server to allow root access from localhost (only). Moreover, the mysql server listens only on 127.0.0.1:3306, as shown by: sudo netstat -npa | head Active Internet connections (servers and established) Proto Recv-Q Send-Q Local Address Foreign Address State PID/Program name tcp 0 0 127.0.0.1:3306 0.0.0.0:* LISTEN 1029/mysqld which means that the connection could have only come from 127.0.0.1 (Note that MySQL is working because I can still connect to it via unix domain sockets) In effect, it seems that all tcp connections originating from 127.0.0.1 to 127.0.0.1 appear to any local daemon to come from the eth0 IP address. Indeed, apache2 allowed me to access PhpMyAdmin after I added allow <eth0 IP address>. The following are my network configurations (redacted): /etc/hosts: 127.0.0.1 localhost 211.x.x.x <host name of eth0> <server name> #IPv6 Defaults follows .... /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 211.x.x.x netmask 255.255.255.0 gateway 211.x.x.x dns-nameservers 8.8.8.8 # dns-* options are implemented by the resolvconf package, if installed dns-search xxxxxxx.com hwaddress ether xx:xx:xx:xx:xx:xx auto eth0:0 iface eth0:0 inet static address 192.168.57.254 netmask 255.255.254.0 broadcast 192.168.57.255 network 192.168.57.0 /etc/ufw/sysctl.conf: #Uncommented the following lines net/ipv4/ip_forward=1 net/ipv6/conf/default/forwarding=1 /etc/default/ufw: DEFAULT_FORWARD_POLICY="ACCEPT" #Changed DROP to ACCEPT /etc/init/internet-sharing.conf (upstart script I wrote), section pre-start script: iptables -A FORWARD -o eth0 -i eth0:0 -s 192.168.57.22 -m conntrack --ctstate NEW -j ACCEPT iptables -A FORWARD -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT iptables -A POSTROUTING -t nat -j MASQUERADE Note again that my problem here is that programs cannot access localhost tcp services, from the server itself, and that access is blocked because the services have access control allowing only 127.0.0.1. I have no problem connecting (as in TCP connections) to services via tcp, even if the services listen only on 127.0.0.1. I do NOT want to connect to the services from another computer.

    Read the article

  • USB Flash not recognised by Windows and BIOS, but works fine in Linux

    - by bbalegere
    I have a Transcend JetFLash 2GB USB Drive.It was working fine and I had been using it occasionally. All of sudden it stopped working in all versions of Windows . The USB Drive is also not recognised by the BIOS.It does not show in the list of bootable devices.(It used show up in the list earlier) However the USB Drive works fine in my Linux Mint 11 OS. Running dmesg gives this [ 941.812192] usb 1-2: new high speed USB device using ehci_hcd and address 4 [ 941.936178] usb 1-2: device descriptor read/64, error -71 [ 942.164188] usb 1-2: device descriptor read/64, error -71 [ 942.380189] usb 1-2: new high speed USB device using ehci_hcd and address 5 [ 942.504138] usb 1-2: device descriptor read/64, error -71 [ 942.732179] usb 1-2: device descriptor read/64, error -71 [ 942.948154] usb 1-2: new high speed USB device using ehci_hcd and address 6 [ 943.364134] usb 1-2: device not accepting address 6, error -71 [ 943.476172] usb 1-2: new high speed USB device using ehci_hcd and address 7 [ 943.892140] usb 1-2: device not accepting address 7, error -71 [ 943.892191] hub 1-0:1.0: unable to enumerate USB device on port 2 [ 944.296190] usb 2-2: new full speed USB device using uhci_hcd and address 3 [ 944.438251] usb 2-2: not running at top speed; connect to a high speed hub [ 944.709928] usbcore: registered new interface driver uas [ 944.729999] Initializing USB Mass Storage driver... [ 944.730509] scsi6 : usb-storage 2-2:1.0 [ 944.730908] usbcore: registered new interface driver usb-storage [ 944.730917] USB Mass Storage support registered. [ 945.736320] scsi 6:0:0:0: Direct-Access JetFlash Transcend 2GB 8.07 PQ: 0 ANSI: 2 [ 945.744547] sd 6:0:0:0: Attached scsi generic sg1 type 0 [ 945.753316] sd 6:0:0:0: [sdb] 3944448 512-byte logical blocks: (2.01 GB/1.88 GiB) [ 945.758274] sd 6:0:0:0: [sdb] Write Protect is off [ 945.758288] sd 6:0:0:0: [sdb] Mode Sense: 03 00 00 00 [ 945.765167] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.765181] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 945.784309] sd 6:0:0:0: [sdb] No Caching mode page present [ 945.784323] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.239512] sdb: sdb1 [ 946.257279] sd 6:0:0:0: [sdb] No Caching mode page present [ 946.257292] sd 6:0:0:0: [sdb] Assuming drive cache: write through [ 946.257302] sd 6:0:0:0: [sdb] Attached SCSI removable disk Looks like there is something wrong the USB Drive.It is not recognised in any computer running Windows. Is there any way to fix this? Any idea why this problem occurred ?

    Read the article

  • unable to access a NAT'ed IP via a VPN on Windows 7

    - by crmpicco
    I connect to a range of servers hosted by one provider via a VPN. I can connect to the VPN fine, however when I then go and try and connect to the server(s) it fails. A NAT'ed IP address that has worked up until today, has stopped working either via SSH/SFTP. As you can see below, if I try and ping the IP then it responds with Destination host unreachable, but, for some reason it says the reply is from 192.168.0.8? If it enter this IP address in my browser, I get nothing. Where is this IP coming from and is there any good reason why I cannot access the IP I am trying to ping? C:\Users\crmpicco>ping 172.26.100.x Pinging 172.26.100.x with 32 bytes of data: Reply from 192.168.0.8: Destination host unreachable. Reply from 192.168.0.8: Destination host unreachable. Reply from 192.168.0.8: Destination host unreachable. Reply from 192.168.0.8: Destination host unreachable. Ping statistics for 172.26.100.x: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), I have the VPN remote host address of 80.75.67.x, which shows me as being connected. But i'm unsure if there is a config issue at the server side or my end that has caused this issue? I have had some recent Win7 (automatic) updates, but it's hard to tell if that's caused this problem. This is my output from arp: C:\Users\cmorton>arp -a Interface: 192.168.0.8 --- 0xe Internet Address Physical Address Type 192.168.0.1 00-18-4d-b9-68-5e dynami 192.168.0.6 00-f4-b9-68-0c-9a dynami 192.168.0.7 08-00-27-f2-9f-d6 dynami 192.168.0.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.251 01-00-5e-00-00-fb static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Interface: 192.168.56.1 --- 0x15 Internet Address Physical Address Type 192.168.56.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.251 01-00-5e-00-00-fb static 224.0.0.252 01-00-5e-00-00-fc static 255.255.255.255 ff-ff-ff-ff-ff-ff static

    Read the article

  • bluetooth connection using pybluez

    - by srj0408
    I am working on bluetooth not exactly on bluetooth stack-development but to use bluetooth in one of my project. I had done all that before using some of the py-bluez commands like hciconfig, hcitool scan , then simple-agents and using serial module inside python. But that was quite random. We were able to connect only one specific device based on its bluetooth address and there was no facility of reconnection once the devices are disconnected. Now i want to try out this stuff in a sequential manner like this (i am doing that all on a RPI and for at present on ubuntu 12.04.) i) Store some names in a file along with some other information with respect to that device. ii) Run a script to find out the device in locality with those names and if any one if found, report that. For this step, i had taken a reference from BTBook , made available from MIT. Below is the script for the same, but that script only search for the single name. from bluetooth import * target_name = "XT1033" target_address = None nearby_devices = discover_devices() for address in nearby_devices: if target_name == lookup_name( address ): target_address = address break if target_address is not None: print "found target bluetooth device with address ", target_address connect_socket(target_address); else: print "could not find target bluetooth device nearby" iii) Connect the device using client sock. But i dont have any device on which i can write a simple python script. My client can be any device that will be publishing data. Now i came through a script in the same book, that actually connect to a client requesting permission to connect to server. from bluetooth import * port = 1 server_sock=BluetoothSocket( RFCOMM ) server_sock.bind(("",port)) server_sock.listen(1) client_sock, client_info = server_sock.accept() print "Accepted connection from ", client_info data = client_sock.recv(1024) print "received [%s]" % data client_sock.close() server_sock.close() here client_sock, client_info = server_sock.accept() provide the client address and port requested to be connected. Can i pass address obtained from the earlier script to this, so that it connect server to the client? iv) Then if client get disconnected, re-connect(a simple polling can be used.) All this stuff can be done using bash and py-bluez functions but i want to do that in a sequential manner.I am not a master in python but i can do some small stuff. Can any one guide me for the same or can direct me to more usefull resource through which i can continue my coding part after finding the "X", "Y" named devices.

    Read the article

  • Create and manage child name servers (glue records) within my domain?

    - by basilmir
    Preface I use a top level domain provider that only allows me to add "normal" third-party name servers (a list where i can add "ns1.hostingcompany.com" type entries... nothing else) AND "child name servers" which i can later attach to my parent account ( ns1.myowndomain.com and an ip address). They do not provide other means of linking up. I want to host my own server and dns, even with just one name server (at first). My setup: Airport Extreme - get's a static ip address from my ISP Mac Mini Server - sits behind the Airport and get's a 10.0.1.2 My problem is that i can't seem to configure DNS correctly. I added a "child nameserver" with my airport's external static ip address at the top level provider, so to my understanding i should have all DNS traffic redirected to my Airport. I've opened port 53 UDP to let the traffic in. Now, what i don't get is this. My Mini Server is sitting on a 10.0.1.2 address and i have setup dns correctly, with an A record to point and resolve my server AND a reverse lookup to that 10.0.1.2. So it's ok for "internal stuff". Here is the clicker... How, when a request comes from the exterior for a reverse lookup, does the server "know" ... well look i have everything in 10.0.1.2 but the guy outside needs something from my real address. I can't begin to describe the MX record bonanza... How do i set this "right"? Do i "need" my Mini Server to sit on the external address directly (i can see how this could be the preferred solution, being close to a "real" server i have in my mind). If not... do i need a PTR record on the 10.0.1.2 server but with the external address in there? My dream: I will extend this "setup" with multiple Mini's in different cities where i work. I want a distributed something (Xgrid comes to mind). PS. Be gentle, i've read 2 books and the subject, and bought both the Lynda Essentials and DNS and Networking to boot, still i'm far from being on top of things.

    Read the article

  • GetHashCode on null fields?

    - by Shimmy
    How do I deal with null fields in GetHashCode function? Module Module1 Sub Main() Dim c As New Contact Dim hash = c.GetHashCode End Sub Public Class Contact : Implements IEquatable(Of Contact) Public Name As String Public Address As String Public Overloads Function Equals(ByVal other As Contact) As Boolean _ Implements System.IEquatable(Of Contact).Equals Return Name = other.Name AndAlso Address = other.Address End Function Public Overrides Function Equals(ByVal obj As Object) As Boolean If ReferenceEquals(Me, obj) Then Return True If TypeOf obj Is Contact Then Return Equals(DirectCast(obj, Contact)) Else Return False End If End Function Public Overrides Function GetHashCode() As Integer Return Name.GetHashCode Xor Address.GetHashCode End Function End Class End Module

    Read the article

  • Email to be sent out from a dedicated server with different IP

    - by ToughPal
    We have three domains hosted on one dedicated server each with its own dedicated IP. Domain A - Has the server primary IP address (default server IP) Domain B - Has its own IP address Domain C - has its own IP address If an email goes out from Domain B then it uses the Domain A IP address in outgoing and this makes emails from Domain B using PHP go straight to spam box of Gmail etc. Is there any way to change the source IP depending on where the email originates from in PHP? What should we change to fix this?

    Read the article

  • Checkbox control in Asp.Net

    - by Sivakumar
    Hello, Actually I'm trying to capture person's current and permanent address. In this case if d current and permanent address same means no need to enter twise. Here I'm using a checkbox. If d checkbox s checked the current address plased in permanent address too. Help me to do tat.

    Read the article

  • What is the best schema design for child collection with a "primary" entity

    - by erg39
    Here is the scenario: You have a Persons table with a one-to-many relationship with an Addresses table, where one of the Address rows is the "primary" Address. Is it better in a normalized schema to Use a Persons.PrimaryAddressID to access the "primary" Address for a Person or Use an Addresses.IsPrimary bit column to reference the "primary" Address for a Person via Addresses.PersonID or Other and why?

    Read the article

  • JPA Inheritance and Relations - Clarification question

    - by Michael
    Here the scenario: I have a unidirectional 1:N Relation from Person Entity to Address Entity. And a bidirectional 1:N Relation from User Entity to Vehicle Entity. Here is the Address class: @Entity public class Address implements Serializable { private static final long serialVersionUID = 1L; @Id @GeneratedValue(strategy = GenerationType.AUTO) privat Long int ... The Vehicles Class: @Entity public class Vehicle implements Serializable { @Id @GeneratedValue(strategy = GenerationType.AUTO) private Long id; @ManyToOne private User owner; ... @PreRemove protected void preRemove() { //this.owner.removeVehicle(this); } public Vehicle(User owner) { this.owner = owner; ... The Person Class: @Entity @Inheritance(strategy = InheritanceType.JOINED) @DiscriminatorColumn(name="PERSON_TYP") public class Person implements Serializable { @Id protected String username; @OneToMany(cascade = CascadeType.ALL, orphanRemoval=true) @JoinTable(name = "USER_ADDRESS", joinColumns = @JoinColumn(name = "USERNAME"), inverseJoinColumns = @JoinColumn(name = "ADDRESS_ID")) protected List<Address> addresses; ... @PreRemove protected void prePersonRemove(){ this.addresses = null; } ... The User Class which is inherited from the Person class: @Entity @Table(name = "Users") @DiscriminatorValue("USER") public class User extends Person { @OneToMany(mappedBy = "owner", cascade = {CascadeType.PERSIST, CascadeType.REMOVE}) private List<Vehicle> vehicles; ... When I try to delete a User who has an address I have to use orphanremoval=true on the corresponding relation (see above) and the preRemove function where the address List is set to null. Otherwise (no orphanremoval and adress list not set to null) a foreign key contraint fails. When i try to delete a user who has an vehicle a concurrent Acces Exception is thrown when do not uncomment the "this.owner.removeVehicle(this);" in the preRemove Function of the vehicle. The thing i do not understand is that before i used this inheritance there was only a User class which had all relations: @Entity @Table(name = "Users") public class User implements Serializable { @Id protected String username; @OneToMany(mappedBy = "owner", cascade = {CascadeType.PERSIST, CascadeType.REMOVE}) private List<Vehicle> vehicles; @OneToMany(cascade = CascadeType.ALL) @JoinTable(name = "USER_ADDRESS", joinColumns = @JoinColumn(name = "USERNAME") inverseJoinColumns = @JoinColumn(name = "ADDRESS_ID")) ptivate List<Address> addresses; ... No orphanremoval, and the vehicle class has used the uncommented statement above in its preRemove function. And - I could delte a user who has an address and i could delte a user who has a vehicle. So why doesn't everything work without changes when i use inheritance? I use JPA 2.0, EclipseLink 2.0.2, MySQL 5.1.x and Netbeans 6.8

    Read the article

  • will mmap use user cpu instead of whole sys cpu? (solaris)

    - by Daniel
    when use mmap to allocate some anonymous mem, we often set the start address as 0/null so mmap will figure out the starting address by itself. And to get the start address, it will work thought the whole virtual memory space to find a hole which could put the chuck of mem to be allocated. I guess this is calculated as user cpu instead of sys cpu. If the virtual memory is fragmented, then the time to find the starting address will use more user cpu, is my understanding correct

    Read the article

  • C automatically assign port

    - by Gary
    Hi, I just wanted to know how to use C to automatically assign a free port (and see what was used) if a specific port number is not provided. For example, i'm using this: struct sockaddr_in address; address->sin_family = AF_INET; address->sin_addr.s_addr = INADDR_ANY; address->sin_port = htons( port ); But how can I replace the sin_port assignment and let C automatically assign for me? Thanks!

    Read the article

  • Changing style of latex description lists.

    - by Halpo
    This should be an easy question for someone out there. I have a description list \begin{description} \item[Name:] Halpo \item[Email Address:] [email protected] \item[Address:] 1234 Ivy Ln \\ Springfield, USA \end{description} It comes back as Name: Halpo Email Address: [email protected] Address: 1234 Ivy Ln Springfield, USA This is for an official document that has style requirements. The First thing is how do I turn off the bold? second how do I have all the text line up with the item labels and still be left justified?

    Read the article

< Previous Page | 171 172 173 174 175 176 177 178 179 180 181 182  | Next Page >