Search Results

Search found 8876 results on 356 pages for 'hardware raid'.

Page 177/356 | < Previous Page | 173 174 175 176 177 178 179 180 181 182 183 184  | Next Page >

  • Old operational master still thinks it is the "one"

    - by Doug
    Hi there, I have a domain with 3 AD servers for now i'll just call them: AD01 (Win 2008 GC, Operations master) AD02 (Win 2008 GC) AD03 (Win 2003 GC) A couple of months there was some hardware issues with AD01 so the operations master, PDC and Infrastructure Master was moved to AD02. All machines where on while this was happening. AD01 (Win 2008 GC) AD02 (Win 2008 GC, Operations master) AD03 (Win 2003 GC) AD01 was then shutdown for a month. Upon starting this machine up with replaced hardware (NIC and RAID card) i now have a weird problem. AD01 Thinks it is operations master still in AD on the local box AD02 & AD03 Thinks AD02 is operations master in AD on both boxes When running DCDIAG on AD01 i get a number of issues (listed below) When running "dcdiag /test:advertising" on AD01: Doing primary tests Testing server: Default-First-Site-Name\AD01 Starting test: Advertising Warning: DsGetDcName returned information for \\ad02.domain.local, when we were trying to reach AD01. SERVER IS NOT RESPONDING or IS NOT CONSIDERED SUITABLE. ......................... AD01 failed test Advertising Running partition tests on : ForestDnsZones Running partition tests on : DomainDnsZones Running partition tests on : Schema Running partition tests on : Configuration Running partition tests on : domain Running enterprise tests on : domain.local When running "dcdiag" on AD01 i get the following errors (excerpt of the Final output): Testing server: Default-First-Site-Name\AD01 Starting test: Advertising Warning: DsGetDcName returned information for \\ad02.domain.local, when we were trying to reach AD01. SERVER IS NOT RESPONDING or IS NOT CONSIDERED SUITABLE. ......................... AD01 failed test Advertising Starting test: FrsEvent There are warning or error events within the last 24 hours after the SYSVOL has been shared. Failing SYSVOL replication problems may cause Group Policy problems. Starting test: NCSecDesc Error NT AUTHORITY\ENTERPRISE DOMAIN CONTROLLERS doesn't have Replicating Directory Changes In Filtered Set access rights for the naming context: DC=ForestDnsZones,DC=domain,DC=local Error NT AUTHORITY\ENTERPRISE DOMAIN CONTROLLERS doesn't have Replicating Directory Changes In Filtered Set access rights for the naming context: DC=DomainDnsZones,DC=domain,DC=local Starting test: Replications [Replications Check,Replications Check] Inbound replication is disabled. To correct, run "repadmin /options AD01 -DISABLE_INBOUND_REPL" [Replications Check,AD01] Outbound replication is disabled. To correct, run "repadmin /options AD01 -DISABLE_OUTBOUND_REPL" So the problem appeasr to be that when i moved the operations master, AD01 never got the memo, and now that it's started up, all the other AD servers don't think its the boss anymore when it trys to replicate etc. So i really need to manually update AD01 so that it knows who the operations master, instrastructure and PDC is - but i'm not having any luck I've been googling for nearly a day and all solutions lead to "the cake is a lie" Your ninja skills will be greatly appreciated

    Read the article

  • The laptop overheat when use linux ubuntu

    - by Rienna
    I use 2 operating system in my laptop. I am using windows 7 and ubuntu 12.04 When I use ubuntu, it's often make my laptop turned into overheat and sometimes turned off suddenly. Why it happen? Is it caused damage to my hardware or because I am using 2 OS? My laptop'specification Processor : Intel(R)Core(TM)2 Duo CPU T6600 @ 2.20Ghz 2.20 GHz RAM : 2 GB System type : 64-bit Operating System

    Read the article

  • How much time do I have to remove a domain controller that was lost using metadata cleanup?

    - by dasko
    I am wondering how long after a Domain Controller has been permanently lost, from the domain due to it dying from hardware perspective, do I have before I have to clean up references of it using meta data cleanup? Planning on doing it soon but not sure if there is anything I should be concerned about. This dead or lost domain controller had no roles other than being a Domain Controller and having integrated Active Directory DNS. As well it held NO FSMO roles, it was just an older replication Domain Controller.

    Read the article

  • What is a reasonable range for signal strength when next to my router?

    - by Jeff
    I know that these things depend largely on specific hardware but I don't even know if I am in the neighborhood. What would a reasonable range of signal strength be when my device is less than 5 feet from my router? House3 is my main router at 61% strength and that seems very low! Repeater is my... repeater which is 50' away in the next room. I'm not terribly concerned with the Repeater until I get my main router settled.

    Read the article

  • HP DL360 G6 NC328i Dual Port Gigabit - Windows Server 2003 R2 Driver Problem

    - by brianjd
    I recently installed Windows Server 2003 R2 (64) on a DL360 G6 without using the SmartStart CD (it didn't like the MSDN media). But when I attempted to install the network drivers post-install using the packages from the HP website, I wasn't successful. Though I selected the correct package, the installer reported I did not have the necessary hardware configuration. Has anyone had a similar experience? Thanks

    Read the article

  • Fastest router for OpenWRT/etc?

    - by marienbad
    I realize OpenWRT Wiki hardware info tells CPU model and MHz for many routers, but MHz doesn't directly map to speed. So... as far as you know, what are some of the fastest OpenWRT-compatible wifi routers out there?

    Read the article

  • Tape Storage - How do I setup a tape backup system for use with my NAS

    - by John Himmelman
    I currently have a QNAP NAS with a raid 5 config (~600gb storage) but don't have a reliable backup solution. I've heard great things about tape backup systems (reliability, durability, etc..). How can I go about setting up a tape backup system? The tape drives seem very expensive (1k+ for a decent one, more than the price of my NAS). What are the important specs to compare and features to take into consideration? Edit: Does anyone have links to some good resources? There is a ton of articles, guides, and sites on this subject, not sure where to start.

    Read the article

  • How do I use an internal SSD as a scratch disk for FCP X?

    - by andrewb
    I'm contemplating setting up my MacBook Air as a video editing machine. If I do this, I'll upgrade to a 256 GB SSD, and I should be able to keep around 100 GB or more free for video editing. The video files would of course be stored externally, but save purchasing some expensive Thunderbolt RAID device (which I suppose is gradually becoming more of an option), it will be slow for read/writes. How can I have a set up where I take advantage of my SSD's speed for a scratch disk/cache for FCP X, but still have the TB(s) of storage of externals? I don't want to have to be moving files constantly back and forth, this is about saving time not wasting it.

    Read the article

  • Intel 520 SSD drives not working with lsi controller on VMware esxi 5

    - by Michael
    We have a problem with our LSI 9266 controller. LSI have vmware drivers which normally show the health status of connected drives, raid controller, battery etc from within the vSphere Client. This driver also allows connectivity from the LSI MSM utility from a windows workstation. The problem is as soon as I connect my intel 520 SSD drives the health status in the vsphere client disappears, also we lose connectivity via the LSI MSM utlity. Any other drives we test are fine, 1TB SAS drives, other SSD drives etc are all OK. The Intel drives are on the compatability list and are supported by LSI but dont work with the VMware driver. If I install a windows OS on the physical server we have no problems. I have logged a ticket with LSI but they havent been very helpful. I am trying to find other people that may have had the same issue and maybe even a fix

    Read the article

  • DHCP server with multiple interfaces on ubuntu, destroys default gateway

    - by Henrik Kjus Alstad
    I use Ubuntu, and I have many interfaces. eth0, which is my internet connection, and it gets its info from a DHCP-server totally outisde of my control. I then have eth1,eth2,eth3 and eth4 which I have created a DHCP-server for.(ISC DHCP-Server) It seems to work, and I even get an IP-address from the foreign DHCP-server on the internet facing interface. However, for some reason it seems my gateway for eth0 became screwed after I installed my local DHCP-server for eth1-eth4. (I think so because I got an IP for eth0, and I can ping other stuff on the local network, but I cannot get access to the internet). My eth0-specific info in /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet dhcp auto eth1 iface eth1 inet static address 10.0.1.1 netmask 255.255.255.0 network 10.0.1.0 broadcast 10.0.1.255 gateway 10.0.1.1 mtu 8192 auto eth2 iface eth2 inet static address 10.0.2.1 netmask 255.255.255.0 network 10.0.2.0 broadcast 10.0.2.255 gateway 10.0.2.1 mtu 8192 My /etc/default/isc-dhcp-server: INTERFACES="eth1 eth2 eth3 eth4" So why does my local DHCP-server fuck up the gateway for eth0, when I tell it not to listen to eth0? Anyone see the problem or what I can do to fix it? The problem seems indeed to be the gateways. "netstat -nr" gives: 0.0.0.0 --- 10.X.X.X ---- 0.0.0.0 --- UG 0 0 0 eth3 It should have been 0.0.0.0 129.2XX.X.X 0.0.0.0 UG 0 0 0 eth0 So for some reason, my local DHCP-server overrides the gateway I get from the network DHCP. Edit: dhcp.conf looks like this(I included info only for eth1 subnet): ddns-update-style none; not authoritative; subnet 10.0.1.0 netmask 255.255.255.0 { interface eth1; option domain-name "example.org"; option domain-name-servers ns1.example.org, ns2.example.org; default-lease-time 600; max-lease-time 7200; range 10.0.1.10 10.0.1.100; host camera1_1 { hardware ethernet 00:30:53:11:24:6E; fixed-address 10.0.1.10; } host camera2_1 { hardware ethernet 00:30:53:10:16:70; fixed-address 10.0.1.11; } } Also, it seems that the gateway is correctly set if I run "/etc/init.d/networking restart" in a terminal, but that's not helpful for me, I need the correct gateway to be set during startup, and i'd rather find the source of the problem

    Read the article

  • Installing Windows Server 2003 on AMD environment

    - by santhosh kumar
    Hi all, Our organisation we have 25 computers and we are trying to setup Windows Server 2003. We are planning to configure Active Directory NAT DNS server Visual Studio Team Foundation Server Subversion (SVN) Trac (Bug tracking tool) FTP server And our Hardware configuration is AMD Athlon 64 X2 Dual (Core processor 5600+, 2.60 GHz) Asus motherboard (M2N series) Transcend 4 GB RAM (800 MHz) 500 GB Hard Disk (RAID enabled) But my colleague is advising me AMD won't suite for servers platforms, and use Intel environment. Also they telling we can't install all the services to one server. I got confusion what to do?... Is really can`t install above services to AMD computer? Thanks...

    Read the article

  • 19" Rackmountable fast storage arrays

    - by Eruditass
    I'm in need of some fast (15+ GB/s write) and somewhat large (50 TB+) storage subsystem with a standard storage interface. I'd prefer something other than Fibre Channel, which admittedly appears to be the most standard interface. RAID 5 is sufficient. What are the cheapest / smallest products from vendors to look at for building this subsystem? I've looked at DDN and TMS so far. Small: Under 20U Cheap: Under a million Edit: I'd really like to cut back costs as much as possible at the expense of capacity. How cheap can these bandwidth requirements be met?

    Read the article

  • Output Audio via HDMI and Analog Out Simultaneously

    - by Alex Miller
    I need to output the system audio from a desktop to both the HDMI output (sending to the display that functions as the room speakers) and via the analog stereo output (to feed the reference input on a microphone array for Skype). The only solution I've found so far for this is an HDMI Audio De-Embedder, but I'd really like to avoid buying another piece of hardware, so I'm hoping there's a way to do this inside software. So: Is there any way to make Windows 7 output all audio over both HDMI and Analog outs, simultaneously?

    Read the article

  • Is post-sudden-power-loss filesystem corruption on an SSD drive's ext3 partition "expected behavior"?

    - by Jeremy Friesner
    My company makes an embedded Debian Linux device that boots from an ext3 partition on an internal SSD drive. Because the device is an embedded "black box", it is usually shut down the rude way, by simply cutting power to the device via an external switch. This is normally okay, as ext3's journalling keeps things in order, so other than the occasional loss of part of a log file, things keep chugging along fine. However, we've recently seen a number of units where after a number of hard-power-cycles the ext3 partition starts to develop structural issues -- in particular, we run e2fsck on the ext3 partition and it finds a number of issues like those shown in the output listing at the bottom of this Question. Running e2fsck until it stops reporting errors (or reformatting the partition) clears the issues. My question is... what are the implications of seeing problems like this on an ext3/SSD system that has been subjected to lots of sudden/unexpected shutdowns? My feeling is that this might be a sign of a software or hardware problem in our system, since my understanding is that (barring a bug or hardware problem) ext3's journalling feature is supposed to prevent these sorts of filesystem-integrity errors. (Note: I understand that user-data is not journalled and so munged/missing/truncated user-files can happen; I'm specifically talking here about filesystem-metadata errors like those shown below) My co-worker, on the other hand, says that this is known/expected behavior because SSD controllers sometimes re-order write commands and that can cause the ext3 journal to get confused. In particular, he believes that even given normally functioning hardware and bug-free software, the ext3 journal only makes filesystem corruption less likely, not impossible, so we should not be surprised to see problems like this from time to time. Which of us is right? Embedded-PC-failsafe:~# ls Embedded-PC-failsafe:~# umount /mnt/unionfs Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Invalid inode number for '.' in directory inode 46948. Fix<y>? yes Directory inode 46948, block 0, offset 12: directory corrupted Salvage<y>? yes Entry 'status_2012-11-26_14h13m41.csv' in /var/log/status_logs (46956) has deleted/unused inode 47075. Clear<y>? yes Entry 'status_2012-11-26_10h42m58.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47076. Clear<y>? yes Entry 'status_2012-11-26_11h29m41.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47080. Clear<y>? yes Entry 'status_2012-11-26_11h42m13.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47081. Clear<y>? yes Entry 'status_2012-11-26_12h07m17.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47083. Clear<y>? yes Entry 'status_2012-11-26_12h14m53.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47085. Clear<y>? yes Entry 'status_2012-11-26_15h06m49.csv' in /var/log/status_logs (46956) has deleted/unused inode 47088. Clear<y>? yes Entry 'status_2012-11-20_14h50m09.csv' in /var/log/status_logs (46956) has deleted/unused inode 47073. Clear<y>? yes Entry 'status_2012-11-20_14h55m32.csv' in /var/log/status_logs (46956) has deleted/unused inode 47074. Clear<y>? yes Entry 'status_2012-11-26_11h04m36.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47078. Clear<y>? yes Entry 'status_2012-11-26_11h54m45.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47082. Clear<y>? yes Entry 'status_2012-11-26_12h12m20.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47084. Clear<y>? yes Entry 'status_2012-11-26_12h33m52.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47086. Clear<y>? yes Entry 'status_2012-11-26_10h51m59.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47077. Clear<y>? yes Entry 'status_2012-11-26_11h17m09.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47079. Clear<y>? yes Entry 'status_2012-11-26_12h54m11.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47087. Clear<y>? yes Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Couldn't fix parent of inode 46948: Couldn't find parent directory entry Pass 4: Checking reference counts Unattached inode 46945 Connect to /lost+found<y>? yes Inode 46945 ref count is 2, should be 1. Fix<y>? yes Inode 46953 ref count is 5, should be 4. Fix<y>? yes Pass 5: Checking group summary information Block bitmap differences: -(208264--208266) -(210062--210068) -(211343--211491) -(213241--213250) -(213344--213393) -213397 -(213457--213463) -(213516--213521) -(213628--213655) -(213683--213688) -(213709--213728) -(215265--215300) -(215346--215365) -(221541--221551) -(221696--221704) -227517 Fix<y>? yes Free blocks count wrong for group #6 (17247, counted=17611). Fix<y>? yes Free blocks count wrong (161691, counted=162055). Fix<y>? yes Inode bitmap differences: +(47089--47090) +47093 +47095 +(47097--47099) +(47101--47104) -(47219--47220) -47222 -47224 -47228 -47231 -(47347--47348) -47350 -47352 -47356 -47359 -(47457--47488) -47985 -47996 -(47999--48000) -48017 -(48027--48028) -(48030--48032) -48049 -(48059--48060) -(48062--48064) -48081 -(48091--48092) -(48094--48096) Fix<y>? yes Free inodes count wrong for group #6 (7608, counted=7624). Fix<y>? yes Free inodes count wrong (61919, counted=61935). Fix<y>? yes embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: ********** WARNING: Filesystem still has errors ********** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Directory entry for '.' in ... (46948) is big. Split<y>? yes Missing '..' in directory inode 46948. Fix<y>? yes Setting filetype for entry '..' in ... (46948) to 2. Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Pass 4: Checking reference counts Inode 2 ref count is 12, should be 13. Fix<y>? yes Pass 5: Checking group summary information embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite: clean, 657/62592 files, 87882/249937 blocks

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • AutoCAD 11 and network file shares

    - by gravyface
    Small network of perhaps half a dozen engineers, currently working on local copies of AutoCAD project files, which are then copied back up to file server (2008 Standard, 1-2 year old Dell server hardware, RAID 5 SAS disks (10k? not positive)) at end of day. To me, this sounds horribly inefficient and error-prone, however, I've been told that "AutoCAD and network files = bad idea" and this is gospel. The network is currently 10/100 (perhaps this is the reason for the "gospel") but all the workstations are within 2 years old and have GbE NICs so an upgrade of the core switch is long overdue. However, I know certain applications don't like network access, at all, and any sign of latency or disruption brings the whole thing crashing down. Anyone care to chime in?

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • Assign fixed IP address via DHCP by DNS lookup

    - by Janoszen
    Preface I'm building a virtualization environment with Ubuntu 14.04 and LXC. I don't want to write my own template since the upgrade from 12.04 to 14.04 has shown that backwards compatibility is not guaranteed. Therefore I'm deploying my virtual machines via lxc-create, using the default Ubuntu template. The DNS for the servers is provided by Amazon Route 53, so no local DNS server is needed. I also use Puppet to configure my servers, so I want to keep the manual effort on the deployment minimal. Now, the default Ubuntu template assigns IP addresses via DHCP. Therefore, I need a local DHCP server to assign IP addresses to the nodes, so I can SSH into them and get Puppet running. Since Puppet requires a proper DNS setup, assigning temporary IP addresses is not an option, the client needs to get the right hostname and IP address from the start. Question What DHCP server do I use and how do I get it to assign the IP address based only on the host-name DHCP option by performing a DNS lookup on that very host name? What I've tried I tried to make it work using the ISC DHCP server, however, the manual clearly states: Please be aware that only the dhcp-client-identifier option and the hardware address can be used to match a host declaration, or the host-identifier option parameter for DHCPv6 servers. For example, it is not possible to match a host declaration to a host-name option. This is because the host-name option cannot be guaranteed to be unique for any given client, whereas both the hardware address and dhcp-client-identifier option are at least theoretically guaranteed to be unique to a given client. I also tried to create a class that matches the hostname like this: class "my-client-name" { match if option host-name = "my-client-name"; fixed-address my-client-name.my-domain.com; } Unfortunately the fixed-address option is not allowed in class statements. I can replace it with a 1-size pool, which works as expected: subnet 10.103.0.0 netmask 255.255.0.0 { option routers 10.103.1.1; class "my-client-name" { match if option host-name = "my-client-name"; } pool { allow members of "my-client-name"; range 10.103.1.2 10.103.1.2; } } However, this would require me to administer the IP addresses in two places (Amazon Route53 and the DHCP server), which I would prefer not to do. About security Since this is only used in the bootstrapping phase on an internal network and is then replaced by a static network configuration by Puppet, this shouldn't be an issue from a security standpoint. I am, however, aware that the virtual machine bootstraps with "ubuntu:ubuntu" credentials, which I intend to fix once this is running.

    Read the article

  • How do i use storage spaces?

    - by Lucas
    I am planning on building a new windows 2012 server for a client and I have no experience in doing so. I have built many linux servers for them and setting up software raid during the install is a trivial matter. I have been unable to confirm that the windows 2012 install process has an analogous process for setting up Storage Spaces during the install. Can Storage Spaces be used as an installation target (configured during setup?) Is it capable of mirror+stripe (RAID10)? We have not ordered the hardware yet, so I'm looking for clarification.

    Read the article

  • Set-and-forget Windows backup software with NAS-support?

    - by Evert
    I am looking for set-and-forget backup software for Windows (Vista & 7, and if possible XP/2003). The idea is that it runs in the background on the clients, and does its thing towards a network-share. In case the HDD of one of these clients spontaneously combusts, all I want to have to do is: replace the drive, insert a USB-stick, boot from it, and restore the machine. It should support drives which use [ICH]-RAID. What are my options here? It looks like WHS meets all the requirements, but I am curious about my other options here.

    Read the article

  • The perfect server room?

    - by splattne
    What do I have to consider when I'm planning a new server room for a small company (30 PCs, 5 servers, a couple of switches, routers, UPS...)? What are the most important aspects in order to protect the hardware? What things do not belong in a server closet? Edit: You may also be interested in this question: Server Room Survival Kit. Thank you!

    Read the article

  • Change programfiles variable on windows

    - by Fire-Dragon-DoL
    I have built a computer for a user that asked me for "speed": an SSD was the obvious solution because what he means by speed is "fast boot time". This solved the problem, however the user is not smart enough to remember that he must install programs on D rather than C (c is the ssd, D is an raid 1 hdd). The only solution that comes in my mind is changing programfiles variable such that will point to D rather than C by default. Otherwise, other solutions are ok but I really can't find anything else at the moment. Does anyone have recommendations for how to accomplish changing the default installation directory in Windows?

    Read the article

  • Persistent Issues on small business network using Cisco 871W and Catalyst Express 500

    - by Ben Campbell
    Being the most qualified (read: still not qualified) to solve our persistant network issues, I've turned to serverfault for guidance. I've done some searching, reading related documentation on cisco.com and tried a bit of troubleshooting. Here is the config: 100mb synchronous connection from a business internet provider (tested multiple times at 100meg at the source) Cisco 871W wireless point & router is where the WAN connection starts (this serves all our wireless). The only wired connection in the 871W is the Catalyst switch listed below. Cisco Catalyst Express 500 (24TT) is where all the wired connections terminate. About 20 Windows workstations and servers (AD/Webservers only). Some services in EC2 including mail and other web servers/apps. I've been TOLD cabling internally should be gigabit-ready. Here are the problems: generally slow download rates from the internet to the desktop/laptop frequent "page cannot be displayed" errors in browsers-sometimes 3 or 4 reloads are necessary... often times CSS wont load or other content requiring the browser to connect to a different server. slow speed within the LAN from workstation to workstation copying files. I would expect extremely fast data transfer workstation to workstation / server to workstation in this simple network. Several things I need to admit: I'm not primarily a network guy. Funding is relatively low, I need to be the guy that finds the solution. I understand most of the terminology and most of the technology. Implementation is where I fail due to lack of experience. Getting to the point: I'm wondering whether experienced network admins think that our small network should be sufficiently served with our current hardware if configured properly... or if we should purchase new equipment and start fresh? If starting fresh is the plan, whatever that new equipment may be is a likely different question entirely. If I haven't provided enough information, I will happily do some troubleshooting and update with the results. I have experience using wireshark and some other tools. Please let me know what you think would be most helpful and thanks in advance. EDIT: I forgot to add that the Cisco applicance will not finish loading the SDM Express console. It hangs every time at the "populating modules... DHCP". It eventually crashes and closes. I've rebooted the hardware and this still happens.

    Read the article

  • How do I recover from a Linux CentOS 4.6 Operating System Crash

    - by Greg Omebije
    Our x86 Linux server running CentOS4.6 has crashed. The machine boots only to the Grub prompt. We have tried using the "rescue mode" to recover the System, but it hasn't worked. How can we fix this problem, so that the machine boots normally? How can we fix this problem to the point were we can recover our files from the server Our Linux Server Configuration: Dell PowerEdge 1950 Intel Xeon 2 HDD (146GB each) 4GB RAM Hardware and Software raid setup CentOS 4.6 We used Sysrecord to boot the computer: the following are the output of fdisk -l Disk /dev/sda: 293.3 GB, 292326211584 255 heads, 63 sectors/track, 35539 Cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x00000080 Device Boot Start End Blocks Id System /dev/sda1 * 1 13 104391 83 Linux /dev/sda2 14 17769 142625070 8e Linux LVM

    Read the article