Search Results

Search found 7325 results on 293 pages for 'windows7 32'.

Page 206/293 | < Previous Page | 202 203 204 205 206 207 208 209 210 211 212 213  | Next Page >

  • Rack layout for future growth

    - by bleything
    We're getting ready to move to a new colo facility and I'm designing the rack layout. While we have a full rack, we only have 12U worth of hardware right now: 1x 1U switch 7x 1U servers 1x 2U server 1x 2U disk shelf The colo facility requires us to front-mount the switch and use a 1U brush strip, so we'll be using a total of 13U of space. Regarding growth, I'm reasonably sure we'll be adding another 4U in servers, 1-2U of network gear, and 2-4U of storage in the mid-term. Specific questions I'm hoping to get help with: where should I mount the switch? the LEDs are on top... should I group the servers by function with space for adding new machines? as an alternative, should I group servers based on whether they are production or staging? where in the rack should I start? in the middle? at the top? at the bottom? equally spaced? Here's a silly little ASCII diagram of what I'm thinking right now. Please feel free to tear my design apart, I've really no idea what I'm doing :) Any advice is very welcome. edit: to be clear, the colo is providing redundant power with UPS and generator, so that's why there's no power gear in the plan, except for the 0U PDU that I didn't diagram. 42 | -- switch ---------------------- 41 | -- brush strip ----------------- 40 | ~~ reserved for second switch ~~ 39 | ~~ reserved for firewall ~~~~~~~ 38 | 37 | -- admin01 --------------------- 36 | 35 | -- vm01 ------------------------ 34 | -- vm02 ------------------------ 33 | ~~ reserved for vm03 ~~~~~~~~~~~ 32 | ~~ reserved for vm04 ~~~~~~~~~~~ 31 | ~~ reserved for vm05 ~~~~~~~~~~~ 30 | 29 | -- web01 ----------------------- 28 | -- web02 ----------------------- 27 | ~~ reserved for web03 ~~~~~~~~~~ 26 | ~~ reserved for web04 ~~~~~~~~~~ 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | -- db01 ------------------------ 15 | +- disks ----------------------+ 14 | +------------------------------+ 13 | ~~ reserved for more ~~~~~~~~~~~ 12 | ~~ db01 disks ~~~~~~~~~~~~~~~~~~ 11 | 10 | +- db02 -----------------------+ 9 | +------------------------------+ 8 | ~~ reserved for db02 ~~~~~~~~~~~ 7 | ~~ disks ~~~~~~~~~~~~~~~~~~~~~~~ 6 | ~~ reserved for more ~~~~~~~~~~~ 5 | ~~ db02 disks ~~~~~~~~~~~~~~~~~~ 4 | 3 | 2 | 1 |

    Read the article

  • Huh? JDK not found? (on Windows 7 64-bit)

    - by Android Eve
    I am setting up a development environment for the latest Android 2.3 on a fresh install of Windows 7 64-bit. I first installed the 64-bit JDK 6 (jdk-6u23-windows-x64.exe). Then, I installed 64-bit Eclipse Classic 3.6 (eclipse-SDK-3.6.1-win32-x86_64.zip). Then, I proceed to install the Android SDK Starter Package: installer_r08-windows.exe. But... upon start it says: "Java SE Development Kit (JDK) not found." Why? I just installed it. Is this a mismatch between 32-bit and 64-bit? How do I solve this? Update (1): I tried setting the %JAVA_HOME% environment variable, as well as setting the Installed JREs in Eclipse, as suggested below. None of these solved the problem. It appears that I am not the only experiencing the problem, as this thread suggests: http://stackoverflow.com/questions/1919340/android-sdk-setup-under-windows-7-pro-64-bit I wonder whether there is a 64-bit version of the Android SDK. Update (2): I used the zip version instead (android-sdk_r08-windows.zip), ran android.bat, updated all SDK packages, and installed the ADT plugin (8.0.1), not before having to check: 'Contact all update sites during install to find required software'. We'll see how this goes... Update (3): It worked! (going to accept @bubu's answer shortly) -- but why doesn't the emulator include the HelloAndroid app when I run it (Ctrl+F11) from Eclipse?

    Read the article

  • Conditionally changing MIME type in nginx

    - by Peter
    I'm using nginx as a frontend to Rails. All pages are cached as .html files on disk, and nginx serves these files if they exist. I want to send the correct MIME type for feeds (application/rss+xml), but the way I have so far is quite ugly, and I'm wondering if there is a cleaner way. Here is my config: location ~ /feed/$ { types {} default_type application/rss+xml; root /var/www/cache/; if (-f request_filename/index.html) { rewrite (.*) $1/index.html break; } if (-f request_filename.html) { rewrite (.*) $1.html break; } if (-f request_filename) { break; } if (!-f request_filename) { proxy_pass http://mongrel; break; } } location / { root /var/www/cache/; if (-f request_filename/index.html) { rewrite (.*) $1/index.html break; } if (-f request_filename.html) { rewrite (.*) $1.html break; } if (-f request_filename) { break; } if (!-f request_filename) { proxy_pass http://mongrel; break; } } My questions: Is there a better way to change the MIME type? All cached files have .html extensions and I cannot change this. Is there a way to factor out the if conditions in /feed/$ and /? I understand that I can use include, but I'm hoping for a better way. Putting part of the config in a different file is not that readable. Can you spot any bugs in the if conditions? I'm using nginx 0.6.32 (Debian Lenny). I prefer to use the version in APT. Thanks.

    Read the article

  • Wireless USB keyboard and mouse can wake system, but then receiver is inactive

    - by BlueMonkMN
    I have a Microsoft brand USB device that acts as a receiver for a wireless Microsoft Keyboard and a wireless Mouse. When it's operating normally, there are LEDs on the device indicating Caps Lock, Num Lock and Function Lock, of which the latter 2 are usually lit. It is plugged into a Dell Isnpiron 531 with Windows 7 32-bit running on an AMD Athlon 64 X2 Dual Core processor 5000+. When the computer goes to sleep (the power indicator on the main box is flashing), I can wake it by moving the mouse. So far all is good. However, something changed in, I think, the past couple weeks (I suspect due to a Microsoft driver update problem). Before the change, after waking the computer, everything would operate normally as far as I could tell, but now after waking the computer, the receiver has no lights on, and the keyboard and mouse are completely unresponsive (which is odd, considering the mouse woke up the computer). There is a button on the receiver that's supposed to reset the wireless connection and flash the lights while it does so, but it has no effect in this state. It's like the receiver doesn't have power (but how would the system know I moved the mouse, unless the power was on until it woke up?). I have checked the BIOS/CMOS settings or whatever you call them, and did not see anything related to USB in the power management section. I have checked Windows 7 device manager and ensured that all the USB Root Hub devices have the setting unchecked for allowing the USB power to be turned off. Like I said, this was working before, and the only thing I can think of that's changed is applying Windows Updates.

    Read the article

  • Poor Write Performance in VM inside Proxmox PVE 2.0

    - by sorsenne
    I am running a PVE 2.0 on a decent Hardware (2 SATA HDDs as RAID1, 12GB RAM, i7 CPU) but the I/O Performance is very poor inside the VM (Ubuntu 11.10 Server). The very same VM was copied to another Server running simply Ubuntu Server with KVM and had better I/O Perf. this is how the HDD is shown in the Guest: ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) ata1.00: ATA-8: ST3000DM001-9YN166, CC49, max UDMA/133 ata1.00: 5860533168 sectors, multi 16: LBA48 NCQ (depth 31/32), AA ata1.00: configured for UDMA/133 scsi 0:0:0:0: Direct-Access ATA ST3000DM001-9YN1 CC49 PQ: 0 ANSI: 5 sd 0:0:0:0: [sda] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 0:0:0:0: [sda] 4096-byte physical blocks sd 0:0:0:0: [sda] Write Protect is off sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA I tested with DD: $ dd bs=1M count=128 if=/dev/zero of=test conv=fdatasync 128+0 records in 128+0 records out 134217728 bytes (134 MB) copied, 19.2222 s, 7.0 MB/s on the Host, this same Test will result with 156 MB/s in average. PS: I am using VirtIO and see no error in dmesg.

    Read the article

  • How can i get more low memory with the following setup:

    - by user539484
    Modules using memory below 1 MB: Name Total = Conventional + Upper Memory -------- ---------------- ---------------- ---------------- MSDOS 14 317 (14K) 14 317 (14K) 0 (0K) HIMEM 1 120 (1K) 1 120 (1K) 0 (0K) EMM386 3 120 (3K) 3 120 (3K) 0 (0K) OAKCDROM 36 064 (35K) 36 064 (35K) 0 (0K) POWER 80 (0K) 80 (0K) 0 (0K) NLSFUNC 2 784 (3K) 2 784 (3K) 0 (0K) COMMAND 2 928 (3K) 2 928 (3K) 0 (0K) MSCDEX 15 712 (15K) 15 712 (15K) 0 (0K) SMARTDRV 30 384 (30K) 13 984 (14K) 16 400 (16K) KEYB 6 752 (7K) 6 752 (7K) 0 (0K) MOUSE 17 296 (17K) 17 296 (17K) 0 (0K) DISPLAY 8 336 (8K) 0 (0K) 8 336 (8K) SETVER 512 (1K) 0 (0K) 512 (1K) DOSKEY 4 144 (4K) 0 (0K) 4 144 (4K) POWER 4 672 (5K) 0 (0K) 4 672 (5K) Free 552 944 (540K) 539 088 (526K) 13 856 (14K) Memory Summary: Type of Memory Total = Used + Free ---------------- ---------- ---------- ---------- Conventional 653 312 114 224 539 088 Upper 47 920 34 064 13 856 Reserved 0 0 0 Extended (XMS)* 64 898 256 2 671 824 62 226 432 ---------------- ---------- ---------- ---------- Total memory 65 599 488 2 820 112 62 779 376 Total under 1 MB 701 232 148 288 552 944 Total Expanded (EMS) 33 947 648 (33 152K Free Expanded (EMS)* 33 538 048 (32 752K * EMM386 is using XMS memory to simulate EMS memory as needed. Free EMS memory may change as free XMS memory changes. Largest executable program size 538 976 (526K) Largest free upper memory block 7 488 (7K) MS-DOS is resident in the high memory area. I'm running MS-DOS 6.22 on VMWare virtual hardware. This is memory state after memmaker pass, so i'm looking for optimization beyond memmaker. Note: NLS drivers (DISPLAY, KEYB, NSLFUNC) are essential for me. Thanks to @mtone for valuable reminder about MSCDEX /E which gave me 16KiB of low memory (see the diff)!

    Read the article

  • Second ip address on same interface CentOS 6.3

    - by user16081
    I tried to add a second LAN addresses in CentOS 6.3 on a brand new install and it's not working. I installed a new copy of CentOS 5.7 and tried the same and it worked right away. Now I'm just trying to setup the alias on the same subnet and it's not working. what am i doing wrong, is this not possible on CentOS 6.3? second ip address on the same interface but on a different subnet CentOS 5.7 it works: DEVICE=eth0 BOOTPROTO=static BROADCAST=192.168.0.255 HWADDR=00:0C:29:01:6F:89 IPADDR=192.168.0.167 NETMASK=255.255.255.0 NETWORK=192.168.0.0 ONBOOT=yes DEVICE=eth0:0 BOOTPROTO=static BROADCAST=192.168.0.255 HWADDR=00:0C:29:01:6F:89 IPADDR=192.168.0.166 NETMASK=255.255.255.0 NETWORK=192.168.0.0 ONBOOT=yes On CentOS 6.3: does not work DEVICE=eth0 BOOTPROTO=static BROADCAST=192.168.0.255 HWADDR=00:0C:29:1E:DE:86 IPADDR=192.168.0.242 NETMASK=255.255.255.0 NETWORK=192.168.0.0 GATEWAY=192.168.0.1 ONBOOT=yes DNS1=205.134.232.138 DNS2=4.4.4.4 DEVICE=eth0:0 BOOTPROTO=static BROADCAST=192.168.0.255 HWADDR=00:0C:29:1E:DE:86 IPADDR=192.168.0.240 NETMASK=255.255.255.0 NETWORK=192.168.0.0 ONBOOT=yes # /etc/init.d/network restart Shutting down interface eth0: Device state: 3 (disconnected) [ OK ] Shutting down loopback interface: [ OK ] Bringing up loopback interface: [ OK Bringing up interface eth0: Active connection state: activated Active connection path: /org/freedesktop/NetworkManager/ActiveConnection/3 [ OK ] # ping 192.168.0.240 PING 192.168.0.240 (192.168.0.240) 56(84) bytes of data. From 192.168.0.242 icmp_seq=2 Destination Host Unreachable Appreciate any advice, thanks Update: Perhaps this is relevant? On CentOS 5.7: # dmesg |grep eth eth0: registered as PCnet/PCI II 79C970A eth0: link up eth0: link up On 6.3: # dmesg | grep eth e1000 0000:02:00.0: eth0: (PCI:66MHz:32-bit) 00:0c:29:1e:de:86 e1000 0000:02:00.0: eth0: Intel(R) PRO/1000 Network Connection e1000: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: None 8021q: adding VLAN 0 to HW filter on device eth0 eth0: no IPv6 routers present

    Read the article

  • Centos: installing SVN tells I don't have perl 1.17. I have installed 5.8

    - by Emerson
    I'm trying to install SVN on a CentOS virtual machine. I used the command that the CentOS wiki tells: http://wiki.centos.org/HowTos/Subversion yum install mod_dav_svn subversion It gives me a few errors: --> Finished Dependency Resolution mod_dav_svn-1.4.2-4.el5_3.1.i386 from base has depsolving problems --> Missing Dependency: httpd-mmn = 20051115 is needed by package mod_dav_svn-1.4.2-4.el5_3.1.i386 (base) subversion-1.4.2-4.el5_3.1.i386 from base has depsolving problems --> Missing Dependency: perl(URI) >= 1.17 is needed by package subversion-1.4.2-4.el5_3.1.i386 (base) Error: Missing Dependency: perl(URI) >= 1.17 is needed by package subversion-1.4.2-4.el5_3.1.i386 (base) Error: Missing Dependency: httpd-mmn = 20051115 is needed by package mod_dav_svn-1.4.2-4.el5_3.1.i386 (base) The thing is that I have Perl 5.8 installed: root@server [~]# rpm -q perl perl-5.8.8-32.el5_5.2 I also don't know why it tells httpd-mmn isn't installed. I have apache installed for sure. From what I read here, it seems I would need to recompile apache. www.sitepoint.com /forums/showthread.php?t=485683 Any ideas? Update: I also tried to install subversion via WHM (11.28.35) and it gives me the same error. By the way, WHM it says: CENTOS 5.5 i686 virtuozzo on server

    Read the article

  • Dell Studio 17 - turning off suddenly

    - by studiohack
    I have a Dell Studio 17 laptop, a refurbished model almost 2 years old...It is currently running Windows 7 32-bit, Home Premium. Via a clean install, it is a Vista upgrade machine...A while back, a problem started to develop while running Vista that it would suddenly just turn off. No warnings, messages, anything. It was like I had the battery out, then just unplugged it from the wall. Just like that. Over several months of this happening (or more), I've observed several things...First, it only seems to happen when I'm doing memory-intensive things, such as watching a online video full screen or running many applications in the background...Second, I can tell when it is about to "flip" as I've termed it, when the fan starts running...the computer gets really hot in places... Anyways, I'm pretty sure this is a hardware problem, because it still exists, even after a Vista-to-7 Upgrade...Is this true? Hardware vs. software? Is there anything I can do to fix this? Is it just a specific component or what? What do you recommend? Thanks!!

    Read the article

  • iptables port forwarding works only for localhost

    - by Venki
    Below is my iptables config. I used this for my accessing a node js website running in port 9000 through port 80. This works fine only if access the website through local host / loop back. When I try to use the ip of eth0, which is assigned by my router through dcp. this does not work, when I use ip like 192.168.0.103 to access the website. I am not able to figure what is wrong here, Already burnt a day in this, still not able to figure out :( Edit: ( more information) Earlier, I was using this configuration to develop the website, i had configured the domain name to point to 127.0.0.1 in the /etc/hosts file. It was working fine, but now I am trying to deploy the website in a vps with static ip, This configuration does not work with both static IP. # redirect port 80 to port 9000 *nat :PREROUTING ACCEPT [57:3896] :INPUT ACCEPT [0:0] :OUTPUT ACCEPT [4229:289686] :POSTROUTING ACCEPT [4239:290286] -A PREROUTING -p tcp -m tcp --dport 80 -j REDIRECT --to-ports 9000 -A OUTPUT -d 127.0.0.1/32 -p tcp -m tcp --dport 80 -j REDIRECT --to-ports 9000 COMMIT # Allow HTTP and HTTPS connections from anywhere (the normal ports for websites and SSL). -A INPUT -p tcp --dport 80 -j ACCEPT -A INPUT -p tcp --dport 443 -j ACCEPT -A INPUT -p tcp --dport 9000 -j ACCEPT -A INPUT -j REJECT

    Read the article

  • SPF record for Gmail?

    - by Chris
    I have DNS, with a SPF TXT record, configured for a domain name. The primary user of the domain name now needs to be able to send both from our SMTP servers, and also from her GMail account. I've seen all the information about adding "include:_spf.google.com" to the SPF TXT record, but, as I look into it, it appears that record is outdated. In particular, I had the user send me a test message, and note that it was: Received: from mail-la0-f50.google.com (mail-la0-f50.google.com [209.85.215.50]) However, _spf.google.com doesn't list that IP address: $ dig +short _spf.google.com txt "v=spf1 ip4:216.239.32.0/19 ip4:64.233.160.0/19 ip4:66.249.80.0/20 ip4:72.14.192.0/18 ip4:209.85.128.0/17 ip4:66.102.0.0/20 ip4:74.125.0.0/16 ip4:64.18.0.0/20 ip4:207.126.144.0/20 ip4:173.194.0.0/16 ?all" (Note that a 209.85.21*8*.0 network is listed, but not 209.85.21*5*.0.) Is there a better way to enable sending from GMail? This user sends to at least one recipient with a strict SPF policy that bounces mail not from a designated host... Many thanks!

    Read the article

  • New Windows Server 2008 R2 WIMP running slower than Windows Server 2003

    - by starshine531
    We recently upgraded a WIMP server from Windows Server 2003 (32 bit) to Windows Server 2008 R2 (64 bit). The new server has significantly better hardware than the old server, yet many processes take much longer than the old box. We have a rather complex web application process that normally takes about 7 seconds on the old box, but on the new one it takes 11-12 seconds. That's down from 15.5 seconds it took before I disabled IPV6. This process involves some queries (some of them involve transactions with maybe 3 queries between the start and commit) and creating and emailing some pdfs. Windows updates are current with a more or less fresh machine. This happens consistently even when we have almost no traffic on the site and memory and cpu aren't being hard pressed at all. The only differences between the servers other than the OS and hardware: 1) When available, we used 64 bit versions of programs 2) The new server uses MySQL 5.5 rather than MySQL 5.1 (I did run the mysql_upgrade program and we use InnoDB for the engine) 3) The new server uses PHP Version 5.3.18 rather than PHP Version 5.3.1 4) With the new OS came IIS7 rather than IIS6 of course. What could be causing better hardware to run so much slower? Let me know if you need more details. Thank you.

    Read the article

  • Umount stale glusterfs partition

    - by Khaled
    I am using glusterfs on several Ubuntu servers: two of them are running glusterfs servers in replication mode. Without any clear error, the glusterfs partition became stale and the system shows this error when I try to access the stale partition: Transport endpoint is not connected Also, when running ls -l on the parent folder I get: d????????? ? ? ? ? ? myfolder I tried all types of commands that I can find to umount this partition, but I could not get it done: umount -l /path/to/mount/point umount -f /path/to/mount/point Also, using fuser command to show processes accessing this folder did not work. Unload the fuse kernel module can not be done as it is clear from the kernel config that fuse is built into the kernel and not a loadable module. I found this line in /boot/config-2.6.32-24-server CONFIG_FUSE_FS=y I have been left with two options: Reboot the system. Create another mount point like myfolder2 and mount this again using sudo glusterfs -f /etc/glustefs/glusterfs.vol /path/to/folder2. Of course, I have chosen to go with option 2. Anyone faced such an issue before? Anyone has a better solution for such a case?

    Read the article

  • HP Procurve 2610 intervlan routing

    - by user19039
    Can anyone tell me why inter vlan routing is working for all vlans except my newly created vlan 4/ I have an hp procurve 2610. Any help would be appreciated. I have basically this 1 switch with all unmanaged switches attached to the core. We have a second 2610 on port 28 Running configuration: ; J9085A Configuration Editor; Created on release #R.11.25 hostname "Core_HP" interface 22 speed-duplex 100-full exit ip routing snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 1-12,17-22,26-27 ip address 192.168.4.6 255.255.255.0 tagged 25 no untagged 13-16,23-24,28 exit vlan 2 name "WAN" untagged 28 ip address 10.254.254.3 255.255.255.0 exit vlan 3 name "Wireless" untagged 13-16,24 ip address 192.168.7.6 255.255.255.0 ip helper-address 192.168.4.2 tagged 27 exit vlan 35 name "guest" untagged 23 tagged 24 exit vlan 4 name "esxi" untagged 25 ip address 10.10.1.1 255.255.248.0 exit ip route 192.168.5.0 255.255.255.0 10.254.254.1 ip route 192.168.6.0 255.255.255.0 10.254.254.1 ip route 0.0.0.0 0.0.0.0 192.168.4.10 show ip route IP Route Entries Destination Gateway VLAN Type Sub-Type M etric Dist. ------------------ --------------- ---- --------- ---------- - --------- ----- 0.0.0.0/0 192.168.4.10 1 static 1 1 10.10.0.0/21 esxi 4 connected 0 0 10.254.254.0/24 WAN 2 connected 0 0 127.0.0.0/8 reject static 0 250 127.0.0.1/32 lo0 connected 0 0 192.168.4.0/24 DEFAULT_VLAN 1 connected 0 0 192.168.5.0/24 10.254.254.1 2 static 1 1 192.168.6.0/24 10.254.254.1 2 static 1 1 192.168.7.0/24 Wireless 3 connected 0 0 show ip Internet (IP) Service IP Routing : Enabled Default TTL : 64 Arp Age : 20 VLAN | IP Config IP Address Subnet Mask Prox y ARP ------------ + ---------- --------------- --------------- ---- ----- DEFAULT_VLAN | Manual 192.168.4.6 255.255.255.0 No WAN | Manual 10.254.254.3 255.255.255.0 No Wireless | Manual 192.168.7.6 255.255.255.0 No esxi | Manual 10.10.1.1 255.255.248.0 No guest | Disabled

    Read the article

  • 0 connected nodes in datastax opscenter

    - by gansbrest
    Installed opscenterd on the separate node outside of the cluster, but within firewall ( aws security group ). Tested all possible ports between agents and opcenter server. No errors in the log.. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Initializing event storage. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Attempting to load all persisted alert rules 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done loading persisted alert rules 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done initializing event storage. 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: Done loading persisted scheduled job descriptions 2013-10-30 01:07:23+0000 [FC_Cluster] INFO: OpsCenter starting up. 2013-10-30 01:07:23+0000 [] INFO: Finished starting new cluster services for FC_Cluster 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.34.10.185 is version u'3.2.2' 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.32.37.251 is version u'3.2.2' 2013-10-30 01:08:04+0000 [FC_Cluster] INFO: Agent for ip 10.82.226.252 is version u'3.2.2' The most interesting part that I can see some data in the opscenter UI, when I stop agents, there is no data displayed, when I start - it show up again, but at the same time it shows 0 connected nodes. Storage capacity is even funnier - 3 of 0 nodes.. Any ideas why that could be happening?

    Read the article

  • Server hang - data loss on reboot, post mortem analysis

    - by rovangju
    A development server I'm responsible for (ext3 on raid 5 w/Debian Squeeze) froze up over the weekend and I was forced to reset it, as in unresponsive from KVM/physical keyboard access, no eth devices responding, etc. Not even the backup process ran (Figures, the one time I don't check for confirmation) So after the reset, it turns out that every trace of disk IO activity that should have happened for a period of ~24H is completely gone. The log files have a big gap in the dates and times. As if the writes were never committed to disk, no processes seemed to have run. Luckily it was a weekend and nothing of value would have been lost and I don't suspect a hack. What can I do in post mortem to this event - to prevent it from ever happening again? I've seen this happen before on a completely different machine running FreeBSD. I am rounding up the disk checking tools right now - but there must be more going on! Mount options: /dev/sda1 on / type ext3 (rw,errors=remount-ro) Kernel: Linux dev 2.6.32-5-686-bigmem Disk/Inodes: 13%/3%

    Read the article

  • Windows 7 Media Center PC not displaying MKV files properly

    - by David
    Does anyone know why Windows Media Center wouldn't correctly display a 16x9 video? I just upgraded my home-built HTPC from Vista Ultimate (hey, it was a giveaway) to Windows 7 Ultimate - clean install. After that, I installed the Divx7 beta (to get .MKV support) and AC3filter (so I could HEAR the MKV files). Previously, under Vista Ultimate (32 bit), I had Arcsoft's Total Theater Pro for playing Blu-Rays and MKV decoding under Media Center. Now when I play a 720p 16x9 MKV file, I get some 'letterboxing' - like it's halfway between 4x3 and 16x9 - with the aspect ration looking alightly squished as a result. Here's the wierd part. If I use the Media Center connection software in my XBox 360 - it plays perfectly, filling the 16x9 screen edge-to-edge, just like Vista's WMC software USED to. Of course, beats the network up because the XBox goes to the HTPC, the HTPC goes to my WHS machine to fetch the data, it comes back to the HTPC, gets transcoded and streamed back to the Xbox. I'm running the latest drivers for an NVidia card (as fetched by Windows 7). I have no idea WHY this is because if I play "ordinary" (i.s. SD) Divx files that are 16x9, they play just fine, scaled right up to my screen's edges. It puzzles me as to why the same machine that properly converts the bits for the Xbox can't display/scale them properly for the attached display. Mind you, Windows Media Player exhibits the same symptoms. Ideas?

    Read the article

  • Ubuntu 13.10 on Acer V5-472 with HD 4000

    - by Hyperboreus
    I have an Acer V5-472 with intel HD4000 graphics chipset and a built-in 1366*768 display. I have installed ubuntu 13.10 amd64 in legacy boot mode with an external monitor. Installation showed no problems, I can boot from HDD and log into my system. The internal display doesn't work and I have to use an external monitor. I have tried the following (found in other threads) to no avail: Setting grub option "acpi_backlight=vendor" or "acpi_osi=Linux" or both. Installing the intel HD drivers for Linux from their homepage. Running in circles, screaming and shouting. The internal display lights up (I can change the brightness with Fn-Left and Fn-Right) but that's all. When I boot, I get a purple splash screen and from then only the external monitor works. I read somewhere that this might be a problem with kernel 3.11? Has anybody ubuntu running on an Acer V5-472? Should I change ubuntu version or use 32-bit instead? In general, how can I get the internal display to work? Edit: The settings-display dialogue shows the internal display correctly with supported resolution of 1366.

    Read the article

  • Synergy, OSX client, Windows 7 server - No mouse on client

    - by Majenko
    I have the following Synergy setup: +------------++------------++------------++------------+ | Mac || Win 7 || Ubuntu 1 || Ubuntu 2 | |c ||s ||c ||c | +------------++------------++------------++------------+ Mac: OS/X Tiger 10.4.11 (G3) Win 7: Windows 7 Ultimate x64 Ubuntu 1 & Ubuntu 2: Desktop 10.10 Now, everything works nicely between the Win7 server and the two Ubuntu machines. What doesn't work is the Mac. I am running the very latest Synergy (1.4.2, downloaded last night). As far as the Mac is concerned everything should be working fine: Synergy 1.4.2 Client on Darwin 8.11.0 Darwin Kernel Version 8.11.0: Wed Oct 10 18:26:00 PDT 2007; root:xnu-792.24.17~1/RELEASE_PPC Power Macintosh Unable to connect to pasteboard. Clipboard sharing disabled. 2011-03-22 09:32:56.725 synergyc[406] Can't register screen saver connection 'com.apple.ScreenSaverDaemon' started client connecting to '192.168.0.202': 192.168.0.202:24800 connected to server entering screen leaving screen entering screen leaving screen But it's just not interacting with the display at all (mouse doesn't move, keyboard does nothing). I have tried running ktrace on synergyc and examining the dump, and the only clue I found was that it was trying to interact with the AccessibilityAPI which was disabled at first. Enabling Accessibility has had no effect whatsoever (it has only stopped the failure to open /var/db/.AccessibilityAPIEnabled in the ktrace dump) Anyone managed to get this to work in OS/X Tiger yet? I used to run the server on OS/X and have the windows / unix machines as clients, but as my Windows is now a laptop I'd like that to be the server.

    Read the article

  • High Load mysql on Debian server stops every day. Why?

    - by Oleg Abrazhaev
    I have Debian server with 32 gb memory. And there is apache2, memcached and nginx on this server. Memory load always on maximum. Only 500m free. Most memory leak do MySql. Apache only 70 clients configured, other services small memory usage. When mysql use all memory it stops. And nothing works, need mysql reboot. Mysql configured use maximum 24 gb memory. I have hight weight InnoDB bases. (400000 rows, 30 gb). And on server multithread daemon, that makes many inserts in this tables, thats why InnoDB. There is my mysql config. [mysqld] # # * Basic Settings # default-time-zone = "+04:00" user = mysql pid-file = /var/run/mysqld/mysqld.pid socket = /var/run/mysqld/mysqld.sock port = 3306 basedir = /usr datadir = /var/lib/mysql tmpdir = /tmp language = /usr/share/mysql/english skip-external-locking default-time-zone='Europe/Moscow' # # Instead of skip-networking the default is now to listen only on # localhost which is more compatible and is not less secure. # # * Fine Tuning # #low_priority_updates = 1 concurrent_insert = ALWAYS wait_timeout = 600 interactive_timeout = 600 #normal key_buffer_size = 2024M #key_buffer_size = 1512M #70% hot cache key_cache_division_limit= 70 #16-32 max_allowed_packet = 32M #1-16M thread_stack = 8M #40-50 thread_cache_size = 50 #orderby groupby sort sort_buffer_size = 64M #same myisam_sort_buffer_size = 400M #temp table creates when group_by tmp_table_size = 3000M #tables in memory max_heap_table_size = 3000M #on disk open_files_limit = 10000 table_cache = 10000 join_buffer_size = 5M # This replaces the startup script and checks MyISAM tables if needed # the first time they are touched myisam-recover = BACKUP #myisam_use_mmap = 1 max_connections = 200 thread_concurrency = 8 # # * Query Cache Configuration # #more ignored query_cache_limit = 50M query_cache_size = 210M #on query cache query_cache_type = 1 # # * Logging and Replication # # Both location gets rotated by the cronjob. # Be aware that this log type is a performance killer. #log = /var/log/mysql/mysql.log # # Error logging goes to syslog. This is a Debian improvement :) # # Here you can see queries with especially long duration log_slow_queries = /var/log/mysql/mysql-slow.log long_query_time = 1 log-queries-not-using-indexes # # The following can be used as easy to replay backup logs or for replication. # note: if you are setting up a replication slave, see README.Debian about # other settings you may need to change. #server-id = 1 #log_bin = /var/log/mysql/mysql-bin.log server-id = 1 log-bin = /var/lib/mysql/mysql-bin #replicate-do-db = gate log-bin-index = /var/lib/mysql/mysql-bin.index log-error = /var/lib/mysql/mysql-bin.err relay-log = /var/lib/mysql/relay-bin relay-log-info-file = /var/lib/mysql/relay-bin.info relay-log-index = /var/lib/mysql/relay-bin.index binlog_do_db = 24avia expire_logs_days = 10 max_binlog_size = 100M read_buffer_size = 4024288 innodb_buffer_pool_size = 5000M innodb_flush_log_at_trx_commit = 2 innodb_thread_concurrency = 8 table_definition_cache = 2000 group_concat_max_len = 16M #binlog_do_db = gate #binlog_ignore_db = include_database_name # # * BerkeleyDB # # Using BerkeleyDB is now discouraged as its support will cease in 5.1.12. #skip-bdb # # * InnoDB # # InnoDB is enabled by default with a 10MB datafile in /var/lib/mysql/. # Read the manual for more InnoDB related options. There are many! # You might want to disable InnoDB to shrink the mysqld process by circa 100MB. #skip-innodb # # * Security Features # # Read the manual, too, if you want chroot! # chroot = /var/lib/mysql/ # # For generating SSL certificates I recommend the OpenSSL GUI "tinyca". # # ssl-ca=/etc/mysql/cacert.pem # ssl-cert=/etc/mysql/server-cert.pem # ssl-key=/etc/mysql/server-key.pem [mysqldump] quick quote-names max_allowed_packet = 500M [mysql] #no-auto-rehash # faster start of mysql but no tab completition [isamchk] key_buffer = 32M key_buffer_size = 512M # # * NDB Cluster # # See /usr/share/doc/mysql-server-*/README.Debian for more information. # # The following configuration is read by the NDB Data Nodes (ndbd processes) # not from the NDB Management Nodes (ndb_mgmd processes). # # [MYSQL_CLUSTER] # ndb-connectstring=127.0.0.1 # # * IMPORTANT: Additional settings that can override those from this file! # The files must end with '.cnf', otherwise they'll be ignored. # !includedir /etc/mysql/conf.d/ Please, help me make it stable. Memory used /etc/mysql # free total used free shared buffers cached Mem: 32930800 32766424 164376 0 139208 23829196 -/+ buffers/cache: 8798020 24132780 Swap: 33553328 44660 33508668 Maybe my problem not in memory, but MySQL stops every day. As you can see, cache memory free 24 gb. Thank to Michael Hampton? for correction. Load overage on server 3.5. Maybe hdd or another problem? Maybe my config not optimal for 30gb InnoDB ? I'm already try mysqltuner and tunung-primer.sh , but they marked all green. Mysqltuner output mysqltuner >> MySQLTuner 1.0.1 - Major Hayden <[email protected]> >> Bug reports, feature requests, and downloads at http://mysqltuner.com/ >> Run with '--help' for additional options and output filtering -------- General Statistics -------------------------------------------------- [--] Skipped version check for MySQLTuner script [OK] Currently running supported MySQL version 5.5.24-9-log [OK] Operating on 64-bit architecture -------- Storage Engine Statistics ------------------------------------------- [--] Status: -Archive -BDB -Federated +InnoDB -ISAM -NDBCluster [--] Data in MyISAM tables: 112G (Tables: 1528) [--] Data in InnoDB tables: 39G (Tables: 340) [--] Data in PERFORMANCE_SCHEMA tables: 0B (Tables: 17) [!!] Total fragmented tables: 344 -------- Performance Metrics ------------------------------------------------- [--] Up for: 8h 18m 33s (14M q [478.333 qps], 259K conn, TX: 9B, RX: 5B) [--] Reads / Writes: 84% / 16% [--] Total buffers: 10.5G global + 81.1M per thread (200 max threads) [OK] Maximum possible memory usage: 26.3G (83% of installed RAM) [OK] Slow queries: 1% (259K/14M) [!!] Highest connection usage: 100% (201/200) [OK] Key buffer size / total MyISAM indexes: 1.5G/5.6G [OK] Key buffer hit rate: 100.0% (6B cached / 1M reads) [OK] Query cache efficiency: 74.3% (8M cached / 11M selects) [OK] Query cache prunes per day: 0 [OK] Sorts requiring temporary tables: 0% (0 temp sorts / 247K sorts) [!!] Joins performed without indexes: 106025 [!!] Temporary tables created on disk: 49% (351K on disk / 715K total) [OK] Thread cache hit rate: 99% (249 created / 259K connections) [!!] Table cache hit rate: 15% (2K open / 13K opened) [OK] Open file limit used: 15% (3K/20K) [OK] Table locks acquired immediately: 99% (4M immediate / 4M locks) [!!] InnoDB data size / buffer pool: 39.4G/5.9G -------- Recommendations ----------------------------------------------------- General recommendations: Run OPTIMIZE TABLE to defragment tables for better performance MySQL started within last 24 hours - recommendations may be inaccurate Reduce or eliminate persistent connections to reduce connection usage Adjust your join queries to always utilize indexes Temporary table size is already large - reduce result set size Reduce your SELECT DISTINCT queries without LIMIT clauses Increase table_cache gradually to avoid file descriptor limits Variables to adjust: max_connections (> 200) wait_timeout (< 600) interactive_timeout (< 600) join_buffer_size (> 5.0M, or always use indexes with joins) table_cache (> 10000) innodb_buffer_pool_size (>= 39G) Mysql primer output -- MYSQL PERFORMANCE TUNING PRIMER -- - By: Matthew Montgomery - MySQL Version 5.5.24-9-log x86_64 Uptime = 0 days 8 hrs 20 min 50 sec Avg. qps = 478 Total Questions = 14369568 Threads Connected = 16 Warning: Server has not been running for at least 48hrs. It may not be safe to use these recommendations To find out more information on how each of these runtime variables effects performance visit: http://dev.mysql.com/doc/refman/5.5/en/server-system-variables.html Visit http://www.mysql.com/products/enterprise/advisors.html for info about MySQL's Enterprise Monitoring and Advisory Service SLOW QUERIES The slow query log is enabled. Current long_query_time = 1.000000 sec. You have 260626 out of 14369701 that take longer than 1.000000 sec. to complete Your long_query_time seems to be fine BINARY UPDATE LOG The binary update log is enabled Binlog sync is not enabled, you could loose binlog records during a server crash WORKER THREADS Current thread_cache_size = 50 Current threads_cached = 45 Current threads_per_sec = 0 Historic threads_per_sec = 0 Your thread_cache_size is fine MAX CONNECTIONS Current max_connections = 200 Current threads_connected = 11 Historic max_used_connections = 201 The number of used connections is 100% of the configured maximum. You should raise max_connections INNODB STATUS Current InnoDB index space = 214 M Current InnoDB data space = 39.40 G Current InnoDB buffer pool free = 0 % Current innodb_buffer_pool_size = 5.85 G Depending on how much space your innodb indexes take up it may be safe to increase this value to up to 2 / 3 of total system memory MEMORY USAGE Max Memory Ever Allocated : 23.46 G Configured Max Per-thread Buffers : 15.84 G Configured Max Global Buffers : 7.54 G Configured Max Memory Limit : 23.39 G Physical Memory : 31.40 G Max memory limit seem to be within acceptable norms KEY BUFFER Current MyISAM index space = 5.61 G Current key_buffer_size = 1.47 G Key cache miss rate is 1 : 5578 Key buffer free ratio = 77 % Your key_buffer_size seems to be fine QUERY CACHE Query cache is enabled Current query_cache_size = 200 M Current query_cache_used = 101 M Current query_cache_limit = 50 M Current Query cache Memory fill ratio = 50.59 % Current query_cache_min_res_unit = 4 K MySQL won't cache query results that are larger than query_cache_limit in size SORT OPERATIONS Current sort_buffer_size = 64 M Current read_rnd_buffer_size = 256 K Sort buffer seems to be fine JOINS Current join_buffer_size = 5.00 M You have had 106606 queries where a join could not use an index properly You have had 8 joins without keys that check for key usage after each row join_buffer_size >= 4 M This is not advised You should enable "log-queries-not-using-indexes" Then look for non indexed joins in the slow query log. OPEN FILES LIMIT Current open_files_limit = 20210 files The open_files_limit should typically be set to at least 2x-3x that of table_cache if you have heavy MyISAM usage. Your open_files_limit value seems to be fine TABLE CACHE Current table_open_cache = 10000 tables Current table_definition_cache = 2000 tables You have a total of 1910 tables You have 2151 open tables. The table_cache value seems to be fine TEMP TABLES Current max_heap_table_size = 2.92 G Current tmp_table_size = 2.92 G Of 366426 temp tables, 49% were created on disk Perhaps you should increase your tmp_table_size and/or max_heap_table_size to reduce the number of disk-based temporary tables Note! BLOB and TEXT columns are not allow in memory tables. If you are using these columns raising these values might not impact your ratio of on disk temp tables. TABLE SCANS Current read_buffer_size = 3 M Current table scan ratio = 2846 : 1 read_buffer_size seems to be fine TABLE LOCKING Current Lock Wait ratio = 1 : 185 You may benefit from selective use of InnoDB. If you have long running SELECT's against MyISAM tables and perform frequent updates consider setting 'low_priority_updates=1'

    Read the article

  • OS X won't see Windows 7 in network (and vice versa)

    - by meds
    I've enabled SMB sharing in OS X Lion and have added folders to share, it says 'Windows Sharing: On' with a green circle next to it (from the sharing window) and that to access the volume I will need to to go to \\192.168.0.17. It also says that the OS X should be visible as 'macbook' in the network. Both my WIndows 7 and OS X are connected to the same network, yet when I try to go to \\192.168.0.17 or from the Mac try to go to my Windows system (smb://192.168.0.6) the two OSs don't see each other. Any ideas why? Attempting to ping the Mac from Windows results in this output in the command prompt: Pinging 192.168.0.17 with 32 bytes of data: Reply from 192.168.0.6: Destination host unreachable. Request timed out. Request timed out. Request timed out. Ping statistics for 192.168.0.17: Packets: Sent = 4, Received = 1, Lost = 3 (75% loss), ipconfig in Windows is: Wireless LAN adapter Wireless Network Connection: Connection-specific DNS Suffix . : Link-local IPv6 Address . . . . . : fe80::8918:efd1:b05c:890f%21 IPv4 Address. . . . . . . . . . . : 192.168.0.6 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 192.168.0.1 Ethernet adapter Bluetooth Network Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Ethernet adapter VMware Network Adapter VMnet1: Connection-specific DNS Suffix . : Link-local IPv6 Address . . . . . : fe80::98ab:63fc:3c07:d837%13 IPv4 Address. . . . . . . . . . . : 192.168.74.1 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : Ethernet adapter VMware Network Adapter VMnet8: Connection-specific DNS Suffix . : Link-local IPv6 Address . . . . . : fe80::80ff:c575:7b50:3a10%14 IPv4 Address. . . . . . . . . . . : 192.168.21.1 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : Tunnel adapter isatap.{2E97D0AE-9E18-4072-AC23-1979BA0DCB79}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{E260CE43-E9A7-4DE0-A88E-4EAFF68ACDDB}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{A5130812-59CE-4DDF-9C35-9433BCED9831}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Teredo Tunneling Pseudo-Interface: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{134BCAE7-CFFF-4A98-8DA0-3708806AABEB}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{8D9E3B8F-161C-4ACE-B211-3EDD694416B2}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : in OS X: lo0: flags=8049<UP,LOOPBACK,RUNNING,MULTICAST> mtu 16384 options=3<RXCSUM,TXCSUM> inet6 fe80::1%lo0 prefixlen 64 scopeid 0x1 inet 127.0.0.1 netmask 0xff000000 inet6 ::1 prefixlen 128 gif0: flags=8010<POINTOPOINT,MULTICAST> mtu 1280 stf0: flags=0<> mtu 1280 en0: flags=8863<UP,BROADCAST,SMART,RUNNING,SIMPLEX,MULTICAST> mtu 1500 options=2b<RXCSUM,TXCSUM,VLAN_HWTAGGING,TSO4> ether c8:2a:14:01:24:c1 media: autoselect (none) status: inactive en1: flags=8863<UP,BROADCAST,SMART,RUNNING,SIMPLEX,MULTICAST> mtu 1500 ether e0:f8:47:0c:fe:04 inet6 fe80::e2f8:47ff:fe0c:fe04%en1 prefixlen 64 scopeid 0x5 inet 192.168.0.17 netmask 0xffffff00 broadcast 192.168.0.255 media: autoselect status: active p2p0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 2304 ether 02:f8:47:0c:fe:04 media: autoselect status: inactive fw0: flags=8863<UP,BROADCAST,SMART,RUNNING,SIMPLEX,MULTICAST> mtu 4078 lladdr 70:cd:60:ff:fe:d8:f1:32 media: autoselect <full-duplex> status: inactive

    Read the article

  • Mac OS X Client With Static DHCP Assignment Requests Wrong IP via Option 50

    - by Starchy
    I have a number of Mac (and a few Linux) laptops getting DHCP from a Force10 layer 3 switch, the only DHCP server on the subnet. There's a global dynamic pool, and for each full-time employee's laptop I have a single IP static pool set by MAC address. One and only one of the clients, running OS X 10.7.5, consistently fails to get a static assignment. The MAC address in the static pool definition has been carefully re-checked. Running tcpdump on a mirrored port when the laptop connects, I see that it is specifically requesting 10.100.0.252 (a dynamic address): 11:32:10.108280 IP (tos 0x0, ttl 255, id 28293, offset 0, flags [none], proto UDP (17), length 328) 0.0.0.0.bootpc > broadcasthost.bootps: [udp sum ok] BOOTP/DHCP, Request from 3c:07:54:xx:xx:xx (oui Unknown), length 300, xid 0x1399da89, Flags [none] (0x0000) Client-Ethernet-Address 3c:07:54:xx:xx:xx (oui Unknown) Vendor-rfc1048 Extensions Magic Cookie 0x63825363 DHCP-Message Option 53, length 1: Request Parameter-Request Option 55, length 9: Subnet-Mask, Default-Gateway, Domain-Name-Server, Domain-Name Option 119, LDAP, Option 252, Netbios-Name-Server Netbios-Node MSZ Option 57, length 2: 1500 Client-ID Option 61, length 7: ether 3c:07:54:xx:xx:xx Requested-IP Option 50, length 4: 10.100.0.252 Lease-Time Option 51, length 4: 7776000 Hostname Option 12, length 10: "host-name" END Option 255, length 0 PAD Option 0, length 0, occurs 8 I haven't been able to find any extra system prefs or unusual software on the laptop. Disabling the interface and rebooting or temporarily setting the IP manually both fail to make any difference. Any suggestions appreciated.

    Read the article

  • Can't find created directory on zfs

    - by maniat1k
    I'm using openSUSE 13.1. I created a new directory on a zpool zfs create zpgd0/iSCSI -o compression=lz4 -o atime=off but I'm not looking on that... So I do it again but I'm getting... zfs create zpgd0/iSCSI -o compression=lz4 -o atime=off cannot create 'zpgd0/iSCSI': dataset already exists adding some data zpool history History for 'zpgd0': 2014-08-11.13:38:21 zpool create -f zpgd0 raidz2 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0490461 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0603473 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0606817 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0670246 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0673599 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0715212 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0722699 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0731193 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0732862 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0806663 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0807385 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0816943 2014-08-11.14:13:09 zpool set autoexpand=on zpgd0 2014-08-11.14:14:32 zfs create zpgd0/espacio 2014-08-19.11:47:47 zfs create zpgd0/iSCSI -o compression=lz4 -o atime=off zpool status -v pool: zpgd0 state: ONLINE scan: none requested config: NAME STATE READ WRITE CKSUM zpgd0 ONLINE 0 0 0 raidz2-0 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0490461 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0603473 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0606817 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0670246 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0673599 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0715212 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0722699 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0731193 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0732862 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0806663 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0807385 ONLINE 0 0 0 scsi-SATA_WDC_WD4001FAEX-0_WD-WMC1F0816943 ONLINE 0 0 0 errors: No known data errors I have no errors but the folder does not appear, so what Can I do? sorry add it zfs list NAME USED AVAIL REFER MOUNTPOINT zpgd0 933K 35,5T 54,7K /zpgd0 zpgd0/iSCSI 54,7K 35,5T 54,7K /zpgd0/iSCSI

    Read the article

  • Reducing IO caused by nginx

    - by glumbo
    I have a lot of free RAM but my IO is always 100 %util or very close. What ways can I reduce IO by using more RAM? My iotop shows nginx worker processes with the highest io rate. This is a file server serving files ranging from 1mb to 2gb. Here is my nginx.conf #user nobody; worker_processes 32; worker_rlimit_nofile 10240; worker_rlimit_sigpending 32768; error_log logs/error.log crit; #pid logs/nginx.pid; events { worker_connections 51200; } http { include mime.types; default_type application/octet-stream; access_log off; limit_conn_log_level info; log_format xfs '$arg_id|$arg_usr|$remote_addr|$body_bytes_sent|$status'; sendfile off; tcp_nopush off; tcp_nodelay on; directio 4m; output_buffers 3 512k; reset_timedout_connection on; open_file_cache max=5000 inactive=20s; open_file_cache_valid 30s; open_file_cache_min_uses 2; open_file_cache_errors on; client_body_buffer_size 32k; server_tokens off; autoindex off; keepalive_timeout 0; #keepalive_timeout 65;

    Read the article

  • ext4 filesystem corruption -- maybe hardware error?

    - by pts
    I'm getting these errors in dmesg after about half an hour after I turn on the computer: [ 1355.677957] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1318420: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251700offset=0(0), inode=1802725748, rec_len=179136, name_len=32 [ 1355.677973] Aborting journal on device sda2-8. [ 1355.678101] EXT4-fs (sda2): Remounting filesystem read-only [ 1355.690144] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1318416: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251699offset=0(0), inode=2194783952, rec_len=53280, name_len=152 [ 1356.864720] EXT4-fs error (device sda2): htree_dirblock_to_tree: inode #1312795: (comm updatedb.mlocat) bad entry in directory: directory entry across blocks - block=5251176offset=1460(13748), inode=1432317541, rec_len=208208, name_len=119 /dev/sda is an SSD, and it's using the noop scheduler. /etc/fstab entry: UUID=acb4eefa-48ff-4ee1-bb5f-2dccce7d011f / ext4 errors=remount-ro,noatime,discard,user_xattr 0 1 System information: $ cat /proc/mounts | grep /dev/sd /dev/sda1 /boot ext2 rw,noatime,errors=continue 0 0 $ cat /etc/lsb-release DISTRIB_ID=Ubuntu DISTRIB_RELEASE=10.04 DISTRIB_CODENAME=lucid DISTRIB_DESCRIPTION="Ubuntu 10.04.3 LTS" $ uname -a Linux leetpad 2.6.35-30-generic-pae #61~lucid1-Ubuntu SMP Thu Oct 13 21:14:29 UTC 2011 i686 GNU/Linux I've run memtest for 7 hours, it didn't found any memory errors. Any obvious ideas what can go wrong in this case? The most reasonable thing I can imagine is that the SSD is silently dropping some write requests, which eventually leads to an EXT4 filesystem inconsistency (but no disk I/O errors). How can this happen? Is there a relevant configuration option I should ensure to be set correctly? What tools should I use to diagnose the hardware failures? Would it be possible to diagnose the SSD failure without overwriting data?

    Read the article

< Previous Page | 202 203 204 205 206 207 208 209 210 211 212 213  | Next Page >