  • SCVMM 2008 R2 problems migrating VM from VS2005 to Hyper-V host

    - by Scott Ivey
    I have System Center Virtual Machine Manager 2008 R2 installed, and have a Hyper-V R2 host and a Virtual Server 2005 host. I'm trying to migrate my machines from the VS2005 host to the Hyper-V host, and keep getting the following error... VMM is unable to complete the requested file transfer. The connection to the HTTP server myserver.mydomain.local could not be established. (Unknown error (0x80072efd)) Recommended Action Ensure that the HTTP service and/or the agent on the machine myserver.mydomain.local are installed and running and that a firewall is not blocking HTTPS traffic. (Note - migrations between Hyper-V hosts managed by the VMM server work fine - my problem is just going from VS2005-Hyper-V hosts) I have no firewalls turned on on either of the servers, and no firewalls in the middle. I've looked all over for answers to this problem, and am getting nowhere. All the articles I find when searching are talking about either V2V or P2V - and i'm just trying to do a straight migrate VM. I've tried rebooting the boxes, changing the BITS SSL port number, restarting services, triple-checking firewalls, etc. Does anyone have any good suggestions as to how I can resolve this problem?

    Read the article

  • Getting SMB file shares working over a PPTP VPN

    - by Ben Scott
    I'm having issues getting SMB file shares working over a PPTP VPN. The server setup consists of a security device (DrayTek V3300) which passes the PPTP authentication to a SBS2003 server running RRAS. The server is the DC and provides DNS and WINS, the single NIC's name server is set to the NIC's IP (192.168...), and DHCP on the DrayTek sets the server IP as the DNS. If I create a new VPN connection in Win7, leaving everything as default apart from the server, username, password and domain, I can: ping everything by IP address resolve IPs with nslookup using their fully-qualified name, as in nslookup fileserver.mydomain.local ping machines by fully-qualified name, as in ping fileserver.mydomain.local However if I try to access a file share: within Explorer, I get "Windows cannot access ..." with "Error code: 0x80004005 Unspecified Error", using net use z: \\fileserver.mydomain.local\share, I get "System error 53 has occurred. The network path was not found." If I add the machine name to my HOSTS file I can use the file share, which is my last-ditch workaround, but I have a number of VPN users and would rather a solution that doesn't involve me trying to hand-edit system files on computers half a country away. If I set the WINS server explicitly in the connection's IPv4 settings I don't have to use the FQN to ping the machine, but that doesn't change anything else. EDIT: The PC I'm having the issue on is running Win 7 Home Premium. After more testing I actually have two other PCs that work, one W7HP, one XP Home, and another Vista PC that doesn't work (not tested as much as the others), all four on the same internet connection (behind the same router). All of them were tested with a straight-forward, all defaults, new VPN configuration.

    Read the article

  • Lenovo Mini Wireless Keyboard N5901: Remap orange "My Computer" button

    - by Jon Schneider
    I have a Lenovo Mini Wireless Keyboard N5901 (a.k.a. Part No. 57Y6336) that I'm using with an HTPC running Windows 7. The remote comes with an orange button in the top-left corner that by default, when pressed, opens the Windows "My Computer" window. I would like to remap / reprogram this button to act like the green "Windows Media Center" button instead on a Windows Media Center (WMC) remote; that is, open Windows Media Center if it isn't already open, or go to the WMC homepage if WMC is already open. I've tried several keyboard-remapping utilities (as recommended in other, more general "how to remap keyboard key?" SuperUser.com questions) including SharpKeys, Key Mapper, and KeyTweak, with no luck so far. None of these utilities recognize the orange button -- they all do recognize that some key was pressed, but display a value for the key of "unsupported" or something similar. I was able to use a utility called Keyboard Scan Code Generator to determine that a press of the orange button has a KeyData value of 16777217 (0x1000001), and a "Virtual Code" value of 182. (The other "media" buttons on the N5901 have the same KeyData value, but different Virtual Code values). I'm not sure at this point where in Windows this keystroke is being interpreted as a command to open "My Computer." There is no special software / driver for this device; it worked out of the box with Windows 7, no special driver install necessary. Is there any way to accomplish this? Thanks in advance for any suggestions!

    Read the article

  • Disable raid member check upon mount to mount damaged nvidia raid1 member

    - by Halfgaar
    Hi, A friend of mine destroyed his Nvidia RAID1 array somehow and in trying to fix it, he ended up with a non-working array. Because of the RAID metadata, the actual disk data was stored at an offset from the beginning. I was able to identify this offset with dd and a hexeditor and then I used losetup to create a loop device with the proper offset, so that I could mount the partition. It was then that I ran into problems, namely that mount says: "mount: unknown filesystem type 'nvidia_raid_member'". I also had this when trying to mount a Linux MD component the other day, and because I can remember that doing that in the past worked, I surmised that it may be some kind of protection. I therefore booted an old Sysrescue CD and tried it there, which worked (because of the older version of mount/libc/kernel/whatever). I still need to try to get more data, and because I don't want to keep using that SysrecueCD, I'd like to be able to mount the disk on my normal system. So, my question is: can the check for a disk being a raid member be disabled? I guess I could also zero out blocks that look like the raid block, but I'd rather not... I made an image of the disk with par2 data, so it's revertable, but still...

    Read the article

  • Video and LAN Cards are not recognized on Intel DG41RQ MB

    - by artyom
    Hello, My 32 bit Debian Etch with Etch-n-Half kernel 2.6.24 and Etch-n-half video driver xserver-xorg-video-intel 2.2.1-1~etchnhalf2 does not recognize my on-board LAN and Video. I can work only with VESA display. And additional PCI LAN card (that I wanted to use for Cross-X-Cabel). output of lspci 00:00.0 Host bridge: Intel Corporation 4 Series Chipset DRAM Controller (rev 03) 00:01.0 PCI bridge: Intel Corporation 4 Series Chipset PCI Express Root Port (rev 03) 00:02.0 VGA compatible controller: Intel Corporation 4 Series Chipset Integrated Graphics Controller (rev 03) 00:1b.0 Audio device: Intel Corporation 82801G (ICH7 Family) High Definition Audio Controller (rev 01) 00:1c.0 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 1 (rev 01) 00:1c.1 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 2 (rev 01) 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) 00:1f.1 IDE interface: Intel Corporation 82801G (ICH7 Family) IDE Controller (rev 01) 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) 04:01.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10 According to MB Spec: Video: Intel G41 Express Chipset Graphics and Memory Controller Hub Graphics (GMCH) LAN: Realtek 8111D Gigabit Ethernet Controller LAN Support When I run dpkg-reconfigure xserver-xorg is suggest i810 driver but X does not start, it does not start with intel driver as well; only vesa. LAN I even can't find in lspci... the last Realtek card is external one 100MB card. Where to start from?

    Read the article

  • Wacom consumer tablet driver service may crash while opening Bamboo Preferences, often after resuming computer from sleep

    - by DragonLord
    One of the ExpressKeys on my Wacom Bamboo Capture graphics tablet is mapped to Bamboo Preferences, so that I can quickly access the tablet settings and view the battery level (I have the Wireless Accessory Kit installed). However, when I connect the tablet to the computer, in wired or wireless mode, and attempt to open Bamboo Preferences, the Wacom consumer tablet driver service may crash, most often when I try to do so after resuming the computer from sleep. There is usually no direct indication of the crash (although I once did get Tablet Service for consumer driver stopped working and was closed), only that the cursor shows that the system is busy for a split second. When this happens, the pen no longer tracks on the screen when in proximity of the tablet (even though it is detected by the tablet itself); however, touch continues to function correctly. To recover from this condition, I need to restart the tablet driver services. I got tired of having to go through Task Manager to restart the service every time this happens, so I ended up writing the following command script, with a shortcut on the desktop for running it with elevated privileges: net stop TabletServicePen net start TabletServicePen net stop TouchServicePen net start TouchServicePen Is there something I can do to prevent these crashes from happening in the first place, or do I have have to deal with this issue until the driver is updated? Windows 7 Home Premium 64-bit. Tablet drivers are up to date. Technical details Action Center gives the following details about the crash in Reliability Monitor: Source Tablet Service for consumer driver Summary Stopped working Date ?10/?15/?2012 2:48 PM Status Report sent Description Faulting Application Path: C:\Program Files\Tablet\Pen\Pen_Tablet.exe Problem signature Problem Event Name: APPCRASH Application Name: Pen_Tablet.exe Application Version: 5.2.5.5 Application Timestamp: 4e694ecd Fault Module Name: Pen_Tablet.exe Fault Module Version: 5.2.5.5 Fault Module Timestamp: 4e694ecd Exception Code: c0000005 Exception Offset: 00000000002f6cde OS Version: 6.1.7601.2.1.0.768.3 Locale ID: 1033 Additional Information 1: 9d4f Additional Information 2: 9d4f1c8d2c16a5d47e28521ff719cfba Additional Information 3: 375e Additional Information 4: 375ebb9963823eb7e450696f2abb66cc Extra information about the problem Bucket ID: 45598085 Exception code 0xC0000005 means STATUS_ACCESS_VIOLATION. The event log contains essentially the same information.

    Read the article

  • Vista Power Management GPO

    - by Matt
    Hi, I've created a loopback GPO that has several settings (both computer and user) including a Custom User Interface (Access 2007 Application) and Power Management (has the computer sleep after being idle for 2 min). I'm also filtering so that this policy does not apply to "Admins" - only to "Users". The problem I'm having is when the "Users" login the Power Management settings don’t work, but they do for "Admins". For testing I'm allowing the "Users" to launch Task Manager and use the Run line, so I'll run Explorer and look at Power Management and it shows the settings from my GPO. So I created a test OU with copies of the aforementioned GPO, but removed the Custom User Interface and found the Power Management settings do work for both the "Users" and "Admins". When I add the Custom UI the Power Management settings break for the "User" but continue to work for "Admins". Do the Power Management options need to have User Interface be "Explorer.exe"? Is this a bug or am I doing this the wrong way? BTW the tablets are using Vista SP2. Any insight or advice would be greatly appreciated. Thanks, Matt

    Read the article

  • How to actually defragment a JFFS2 filesystem

    - by Julie in Austin
    I have searched all over the Internet, including on a number of StackExchange forums, for a workable method for defragmenting a JFFS2 filesystem and cannot find an answer. The system in question has a 256MB NAND flash part. It is being accessed as a MTD device which is divided into three partitions. The third partition is where the root file system is being stored as a JFFS2 file system. The issue is that writes to the root file system have non-deterministic performance due to the usual issues of the JFFS2 garbage collector deciding to run at the worst possible times. When that happens, the product is hung for some unknown length of time while the garbage collector (and pdflush) run. Changing the file system isn't an option. The solution needs to be something that can run during off-hours that after having been run results in more predictable write performance. Right now I am working on a program that will attempt to force the garbage collector to run, then delete the file with the hope that all of the freed nodes are suddenly more readily available and make writes perform better. Thoughts?

    Read the article

  • Can I change the file system on the OS partition on Server 2008 R2?

    - by KCotreau
    I have a client using R1Soft Continuous Data Protection backup, and two of the Server 2008 R2 boxes were erroring out with these errors: Unable to obtain NTFS volume data for device '\\?\Volume{f612849e-7125-11e0-8772-806e6f6e6963}': Incorrect function. Unable to discover information for filesytem volume '\\?\Volume{f612849e-7125-11e0-8772-806e6f6e6963}'; Unable to obtain NTFS volume So I backed up all the registry entries with this, {f612849e-7125-11e0-8772-806e6f6e6963}, in it, and deleted them based on some VERY sparse info from R1Soft. I then decided to restore them before I rebooted, and do a system state backup first using MS backup, and even it errored out saying that there were FAT32 partitions. This was a major clue as the only two computers with problems had these FAT32 partitions. I figured if MS backup can't backup something, any other program is likely to have problems. Also, now that I realized the servers had FAT32 partitions on them, the error referencing NTFS takes on more weight. The partitions on both servers have the label "OS", but on one of the computers, it is given a letter, but on the other not. So I am thinking if I just convert the file systems from FAT32 to NTFS, it may solve the backup problem. So the question is this: Can I just convert those partitions, and does anyone have any concrete knowledge of any major downsides, like the servers not coming back up (of course, I would do one at a time)? My thinking is that the answer is probably at least 95% no, but they are production servers, so I wanted to get some second opinions.

    Read the article

  • Windows 7 Sysprep Default User

    - by Demonwolf
    I seem to be having a problem with implementing my sysprep. I have been playing with Windows 7, WAIK, Server 2008 R2 and various other things. I managed to create a WIM with everything I need installed and I have worked out the autounattend.xml. I now have a Windows 7 64-bit complete unattended install from a USB device. It has all my programs, setting and everything done except one thing - the default profile set up 100% correctly. I have created a mostly set up default profile. I booted into audit mode, customized the Administrator account (mostly anyway) and then used sysprep with an unattend.xml file containing the copyprofile=true command. The file was set up with the WSIM and does not contain any extra info. This all works wonderfully. I recreated the WIM and all was good. I then decided to move the default location of the visible stuff in the user profile (Documents, Music, Pictures etc.) without changing the location of Appdata or other hidden folders. This is where things went a little... wrong. I went to the user folder (generally has the User name) with all the other folders in it. I right clicked on My Documents, found the location tab and changed it to M:\Documents. Now if I run sysprep /generalize /oobe /reboot /unattend:unattend.xml it starts the generalise... then spits out a fatal error and goes no further. The setuperr.log contains the following errors: 2011-08-18 23:21:43, Error [0x0f0043] SYSPRP WinMain:The sysprep dialog box returned FALSE 2011-08-18 23:31:57, Error [0x0f0082] SYSPRP LaunchDll:Failure occurred while executing 'C:\Windows\System32\slc.dll,SLReArmWindows', returned error code -1073425657 2011-08-18 23:31:57, Error [0x0f0070] SYSPRP RunExternalDlls:An error occurred while running registry sysprep DLLs, halting sysprep execution. dwRet = -1073425657 2011-08-18 23:31:57, Error [0x0f00a8] SYSPRP WinMain:Hit failure while processing sysprep generalize internal providers; hr = 0xc004d307 Does anyone have any ideas how I can redirect My Documents and other items in a user file to a second drive in the default profile so it affects each person logging in?

    Read the article

  • Connection speed drops from 1 Gbps to 10 Mbps (Vista 64)

    - by Kevin Hakanson
    I recently got a Windows Home Server (HP MediaSmart Server EX490) setup so I could do backups and other things. However, I am having trouble on my Vista 64 PC. The backup will be making great progress, then it will just slow down. At one point, I noticed the lights on my Netgear GS105 indicated it was not using a 1000 Mbps connection, but a 10 Mbps one. I checked the Status of Local Area Connection (Intel(R) 82567V-2 Gigabit Network Connection) and that also showed the same slow speed. This has happened several times in the last couple days. When I disabled the network device, and then enabled it, it established the 1 Gpbs connection again. However, some of the times the Sent Bytes Activity on the Status windows indicate that the data flow is still slow (100 to 1000 bytes every couple seconds). Obviously, at this rate I could backup faster to floppy disk. :) My question is how to diagnose and fix this problem. When I look at the Administrative Events, I do a Errors: Bonjour Service 456: ERROR: read_msg errno 10054 (An existing connection was forcibly closed by the remote host.) And a Warning: e1yexpress Intel(R) 82567V-2 Gigabit Network Connection Link has been disconnected. I am suspicious there is some power saving mode. I found a post suggesting System Idle Power Saver(SIPS) may be the issue. I am going to try that, but looking for other suggestions or diagnostic advice. I have several new items in this configuration: server, client software, switch and cat6 cables.

    Read the article

  • Benchmarking a file server

    - by Joel Coel
    I'm working on building a new file server... a simple Windows Server box with a few terabytes of disk space to share on the LAN. Pain for current hard drive prices aside :( -- I would like to get some benchmarks for this device under load compared to our old server. The old server was installed in 2005 and had 5 136GB 10K disks in RAID 5. The new server has 8 1TB disks in two RAID 10 volumes (plus a hot spare for each volume), but they're only 7.2K rpm, and of course with a much larger cache size. I'd like to get an idea of the performance expectations of the new server relative to the old. Where do I get started? I'd like to know both raw potential under different kinds of load for each server, as well an idea of what our real-world load looks like and how it will translate. Will disk load even matter, or will performance be more driven by the network connection? I could probably fumble through some disk i/o and wait counters in performance monitor, but I don't really know what to look for, which counters to watch, or for how long and when. FWIW, I'm expecting a nice improvement because of the benefits of having two different volumes and the better RAID 10 performance vs RAID 5, in spite of using slower disks... but I'd like to get an idea of how much.

    Read the article

  • Google Apps for Domains, Multiple Domains

    - by belliez
    I have a primary google apps for domains account which I use for my personal email, calender, docs etc and is great. I also receive my pop3 company email via settings-Get mail from other accounts in my account. Due to spam I want to make use of gmail servers for my company email and have two options: [1] Add my second domain as a domain alias [2] Create a new apps for domains account If I do [1] above do I access (send and receive) my company email as if it was a separate account or is it merged into my primary domain. I want the two seperated. If I perform [2] can I share my contacts / calender between the two? I also have Act! contact manager which syncs to my primary domain and it is getting messy now with personal and work contacts being changed / sync'd to my Act CM software. I want to try and separate my personal and work contacts (but make the work them avaiable in my primary domain). Hope this makes sense! Your suggestions are gratefully accepted. Thank you

    Read the article

  • Problems migrating software RAID 5 to new server (linux)

    - by leleu
    I have a CentOS setup with sw RAID5 that holds my data. Well, the server died, so I bought another box to migrate my drives to. Only thing is, I cannot get the RAID array rebuilt (not even sure it needs rebuilding, might just need the /dev/md0 mapping created... but I don't even know how to determine what I need!) Some details: RAID5 software (used mdadm) 4x 250GB drives (2 are SATA, 2 are EIDE -- would this matter? It worked fine in the other box...) latest CentOS distro built using mdadm I've got a decent amount of experience with standard linux stuff, but the hardware level stuff runs me in circles. I've spent some time googling and elsewhere here on SF, so please be kind for my newbie questions :). My question is this: how can I diagnose the problem? For all I know, I'm using the wrong device blocks when I try to rebuild the array, but I can't find the command to display only the devices that have some physical attachment. Is there some simple way for me to run mdadm, having it scan over all my physical drives, and say "hey, drives 2,5,6,7 are a software array, want me to mount it?" I basically just took the drives from my old box and put it into my new one. They show up in the BIOS. What steps do I need to take in order to get the array up, running, and mounted? Thanks in advance!

    Read the article

  • SuperMicro BMC on OpenSuSE Linux --cannot access from LAN

    - by Kendall
    Hi, I have an (old) SMC-001 IPMI device on an (old) X6DVL-EG2 motherboard. My problem is that I cannot access the BMC from LAN. I'm also getting some interesting output from ipmitool. First, the setup. I enable Console Redirection in the BIOS, turn BIOS Redirection after POSt to "disabled". I then modprobe'ed for ipmi_msghandler, ipmi_devintf and ipmi_si. I then found ipmi0 under /dev. So far so good. Since I want console redirection over serial, I modified /boot/grub/menu.lst: http://pastebin.com/YYJmhusQ I then modified "/etc/inittab" as follows: S1:12345:respawn:/sbin/agetty -L 19200 ttyS1 ansi Networking I set as following, using "ipmitool" ipaddr: 192.168.3.164 netmask: 255.255.255.0 defgw: 192.168.3.1 The above are correct for my environment. To test it I do: ipmitool -I open chassis power off which responds by powering off the machine. When I to access from another computer on the network, however, I get an error message: host# ipmitool -I lanplus -H 192.168.10.164 -U Admin -a chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status "Admin" seems to be a valid user name: host# ipmitool -I open user list 1 2 Admin true false true USER The interesting output from ipmitool I initially mentioned: host # ipmitool -I open lan set 1 access on Set Channel Access for channel 1 failed: Request data field length limit exceeded Also, newload4:/home/gjones # ipmitool channel info 1 Channel 0x1 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : session-less Active Session Count : 0 Protocol Vendor ID : 7154 Get Channel Access (volatile) failed: Request data field length limit exceeded The output of "ipmitool -I open lan print 1" is here: http://pastebin.com/UZyL6yyE Any help/suggestions is greatly appreciated; I've been working with this thing for a few hours now with no success.

    Read the article

  • AirPort Express Discoverability

    - by andybjackson
    I bought an AirPort Express to enable music in a different part of a friend's house using the AirTunes feature. Unfortunately, iTunes or the AirPort Utility don't reliably discover the existence of the device. If I use the "Configure Other..." function within the AirPort Utility and enter the AirPort Express' IP address and password, then I can reliably get access in a daughter window to configure it. This seems to nudge the underlying AirPort Utility into "finding" and displaying the AirPort Express, which it doesn't do on its own even after clicking the "Rescan" button. iTunes then also seems to cotton on to this discovery and present the AiportExpress as an AirTunes option at the bottom right of iTunes. Things then works as we'd like them to. If I close down the AirPort Utility, then iTunes loses the AirPort Express AirTunes speaker, often giving "An unkown error (-15006) occurred while connecting to the remote speaker". Of course, starting the Airport Utility, forcing it to recognise the Airport Express and then starting iTunes, isn't the ease of use I was after. Background info: iTunes is running on Windows XP. The AirPort Express is running in wireless client mode (i.e. is connecting to an unsecured wireless network in the house with nothing connected to its ethernet port). The network router is a Swisscom Motorola 3347NWG (with firmware 7.8.5r1). I have already tried: Disabling the Windows XP firewall Updating the AirPort Express firmware, the AirPort Utility and the router firmware Ensuring Wireless privacy and similar potetnially problematic router settings are off Solutions, or even just ideas of other things to try would be gratefully received.

    Read the article

  • Simple P2V help from Linux to Windows

    - by Ke.
    I have two OS's installed on different drives in my PC. One linux (Centos 5.4) and one windows 7. Its getting tiresome to constantly have to stop and restart the PC when I want to use either OS. I would very much like to use Windows 7 as my host OS and access my linux OS from within Windows. However, im having trouble deciphering exactly how to do this (many of the articles seem confusing and a bit overkill) From what i have seen its possible to use VMWare converter to convert the physical linux image to a virtual image so that I can use it in windows. As im having problems understanding how this is done, I would really appreciate a step by step guide (for a newbie), or any simple tutorials that you can point me at. Some questions beforehand: 1) My linux image is around 80gb, do i need to take this into consideration? The linux drive is around 180gb in total. All my other drives are NTFS non writeable in linux (as I use them in windows and ntfs is dodgy in linux), so probably not possible to move the image over to my ntfs drives 2) Can I just zip the linux files up somehow and transfer it to windows to create the p2v? 3) Is it possible to do the P2V conversion while I am logged into windows. I can see the actual linux drive loaded in disk manager, but windows doesnt read linux file systems so im confused as to how to access the linux drive if this is possible. 4) Or will i need to do the whole p2v conversion inside linux? Cheers, any help is much appreciated Ke (a confused p2v newbie)

    Read the article

  • Setting up SQL Server 2005 to use all available memory in 32bit Windows Server 2003 - and verifying

    - by Rizwan Kassim
    There are a number of questions along this line - but they either sometimes contradict each other, or don't show how to properly verify that everything is actually working - hopefully this can be comprehensive... I'm running SQL Server 2005 SP3 Standard on Windows Server 2003 R2 Standard. My server has 8GB of memory installed - my system is almost entirely used as a Database Server - there are some services running on them, but the OS + services can run within 1Gb of RAM. What I've done (please tell me if I'm doing something wrong): /3GB in the boot.ini. (To increase the amount of user-space memory available - info) /PAE in the boot.ini. (Windows claimed to be doing PAE even without this switch, somethow.) Enabled AWE in SQL Server. Enabled Lock Pages in Memory Option for users SYSTEM and Local Service. (info). SQL Server Standard doesn't seem to use this until Cumulative Update 4, which isn't installed on my server. (info) Set Min/Max Memory to : 1024Mb/5112Mb After doing all the above, we definately saw a level of improvement - but I'd like now to verify my settings, make sure that I'm making full use of the memory available. (There appeared to be a slowdown when max = 7Gb, so I edged off from that value, but it might have been just perceptual.) To verify, I checked the following levels in PerfMon : Process(sqlserv):Working Set : 76386304 SQL Server(Memory Manager) : Total Server Memory : 3538944 (I saw a doc that noted that this wasn't the full memory used by SQL Server, so I'm not sure whether to trust it) So -- my questions... Should my max be around 7Gb? If not, what should it be? Why is total server memory at 3.5G, when it's been allocated 5G? What is the proper metric for the amount of memory allocated to SQL Server? The Working Set seems a bit large... Am I possibly missing any steps in the setup? Any recommended resources on starting to tune the caching system now? Thanks

    Read the article

  • Error 0x80300001 Installing Windows Server 2008 R2 64bit on FastTrak TX4660 RAID volume

    - by Konstantin Boyandin
    I am trying to install Windows Server 2008 R2 Enterprise 64bit on the following hardware: motherboard Intel DBS1200BTL Promise FastTrak TX4660 RAID controller 4 disks set up in two RAID1 arrays (handled by FastTrak) I am trying to install Windows so it would boot from RAID1 volume created with the FastTrak controller. The installation goes as in the manual, I insert the disk with the driver, select 'Browse' and specify the correct driver, it finds all the RAID arrays but notifies me that error 0x80300001 happened, Windows can't be installed on the mentioned RAID volumes, since they may not be bootable (even though the target RAID volume is the first in boot options list). If I proceed with the installation, Windows copies and unpacks itself, performs other standard actions after that. After the computer is restarted, it won't boot (Windows Boot Manager appears in the boot devices list; however, neither it nor the RAID volume itself does not boot). Is it a known problem? I can attach the boot disks to the motherboard and use its RAID capabilities instead, but I'd prefer FastTrak ones. Driver version is 1.3.0.4. Thanks.

    Read the article

  • Oracle® Database Express Edition roblem running on Win Server 2003 with MS SQl Server 2008 [closed]

    - by totoz
    Hi I have on Win Server 2003 MS SQL Server 2008 and also IIS is running. I try learn Oracle, so first I installed Oracle® Database Express Edition. I tried connect viac web browser on Oracle Server on url http://127.0.0.1:8080/apex I got this expcetion in browser The page cannot be found The page you are looking for might have been removed, had its name changed, or is temporarily unavailable. Please try the following: Make sure that the Web site address displayed in the address bar of your browser is spelled and formatted correctly. If you reached this page by clicking a link, contact the Web site administrator to alert them that the link is incorrectly formatted. Click the Back button to try another link. HTTP Error 404 - File or directory not found. Internet Information Services (IIS) Technical Information (for support personnel) Go to Microsoft Product Support Services and perform a title search for the words HTTP and 404. Open IIS Help, which is accessible in IIS Manager (inetmgr), and search for topics titled Web Site Setup, Common Administrative Tasks, and About Custom Error Messages. Why I can not log on Oracle Home Page?

    Read the article

  • Vista logs into black screen, "Application Error 0xc0000022" for explorer.exe

    - by IMAPC
    Whenever I attempt to log into a Windows Vista computer (the only account on it), I'm presented with a black screen & a cursor. I can open Task Manager, and from there I can launch applications. It seems to be using Aero Basic (instead of the full Aero which I had set as default before the problem started). When attempting to launch "explorer.exe" I get "explorer.exe - Application Error 'The application failed to initialize properly (0xc0000022). Click OK to terminate the application.'" Every now and then I get an error along the lines of "the application has failed to start because its side by side configuration is incorrect please see the application event log for more detail." I can boot into safe mode successfully, but I still get the black screen when I log into it in regular mode. I've tried most of the suggestions here, but did not work. I'm attempting to back up everything right now in case the only fix is to reinstall Windows. Has anyone seen this before?

    Read the article

  • Ext3 fs: Block bitmap for group 1 not in group (block 0). is fs dead?

    - by ip
    Hi, My company has a server with one big partition with Mysql database and php files. Now this partition seems to be corrupted, as reported from kernel messages when I tried to mount it manually: [329862.817837] EXT3-fs error (device loop1): ext3_check_descriptors: Block bitmap for group 1 not in group (block 0)! [329862.817846] EXT3-fs: group descriptors corrupted! I've tried to recovery it running tools from a PLD livecd. These are the tools I have tested: - e2retrieve - testdisk - photorec - dd_rescue/dd_rhelp - ddrescue - fsck.ext2 - e2salvage without any success. dumpe2fs 1.41.3 (12-Oct-2008) Filesystem volume name: /dev/sda3 Last mounted on: <not available> Filesystem UUID: dd51610b-6de0-4392-a6f3-67160dbc0343 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal filetype sparse_super Default mount options: (none) Filesystem state: not clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 9502720 Block count: 18987570 Reserved block count: 949378 Free blocks: 11555345 Free inodes: 11858398 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 16384 Inode blocks per group: 512 Last mount time: Wed Mar 24 09:31:03 2010 Last write time: Mon Apr 12 11:46:32 2010 Mount count: 10 Maximum mount count: 30 Last checked: Thu Jan 1 01:00:00 1970 Check interval: 0 (<none>) Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 128 Journal inode: 8 Journal backup: inode blocks dumpe2fs: A block group is missing an inode table while reading journal inode There's any other tools I have to test before considering these disk definitely unrecoverable? Many thanks, ip

    Read the article

  • qemu-img: Could not open $FILE

    - by HTTP500
    I received a single-file VMDK from a vendor that has a virtual appliance for a particular product I'm interested in evaluating. We run a KVM solution (Proxmox) so I tried converting the file but on that system qemu-img blows up. (I was able to convert (multipart) VMDK files from bitnami without error.) So I figured I'll just yum install qemu-img on a RHEL 6.3 VM and do it there. But despite the fact that I can file the file just fine when I run qemu-img on it I get this error that it can't open the file: [root@host dir]# file 1.vmdk 1.vmdk: VMware4 disk image [root@host dir]# qemu-img info 1.vmdk qemu-img: Could not open 'vmdk' I've seen some other people post on the interwebs that they've had this problem but none of them seem to have a resolution. Does anyone have any ideas? I have checked the MD5SUM already. EDIT1: [root@host dir]# qemu-img info -f vmdk 1.vmdk qemu-img: Could not open '1.vmdk' EDIT2: Ran strace per suggestion. Not sure what to look for... Here is a possible: ioctl(3, CDROM_DRIVE_STATUS, 0x7fffffff) = -1 ENOTTY (Inappropriate ioctl for device)

    Read the article

  • What tells initramfs or the Ubuntu Server boot process how to assemble RAID arrays?

    - by Brad
    The simple question: how does initramfs know how to assemble mdadm RAID arrays at startup? My problem: I boot my server and get: Gave up waiting for root device. ALERT! /dev/disk/by-uuid/[UUID] does not exist. Dropping to a shell! This happens because /dev/md0 (which is /boot, RAID 1) and /dev/md1 (which is /, RAID 5) are not being assembled correctly. What I get is /dev/md0 isn't assembled at all. /dev/md1 is assembled, but instead of using /dev/sda2, /dev/sdb2, /dev/sdc2, and /dev/sdd2, it uses /dev/sda, /dev/sdb, /dev/sdc, /dev/sdd. To fix this and boot my server I do: $(initramfs) mdadm --stop /dev/md1 $(initramfs) mdadm --assemble /dev/md0 /dev/sda1 /dev/sdb1 /dev/sdc1 /dev/sdd1 $(initramfs) mdadm --assemble /dev/md1 /dev/sda2 /dev/sdb2 /dev/sdc2 /dev/sdd2 $(initramfs) exit And it boots properly and everything works. Now I just need the RAID arrays to assemble properly at boot so I don't have to manually assemble them. I've checked /etc/mdadm/mdadm.conf and the UUIDs of the two arrays listed in that file match the UUIDs from $ mdadm --detail /dev/md[0,1]. Other details: Ubuntu 10.10, GRUB2, mdadm 2.6.7.1 UPDATE: I have a feeling it has to do with superblocks. $ mdadm --examine /dev/sda outputs the same thing as $ mdadm --examine /dev/sda2. $ mdadm --examine /dev/sda1 seems to be fine because it outputs information about /dev/md0. I don't know if this is the problem or not, but it seems to fit with /dev/md1 getting assembled with /dev/sd[abcd] instead of /dev/sd[abcd]2. I tried zeroing the superblock on /dev/sd[abcd]. This removed the superblock from /dev/sd[abcd]2 as well and prevented me from being able to assemble /dev/md1 at all. I had to $ mdadm --create to get it back. This also put the super blocks back to the way they were.

    Read the article

  • How to permanently "renice" a process on Mac OS X (or iOS, etc)?

    - by mralexgray
    I use a nice (free) process manager called ATMonitor for Mac OS X that has a lot of cool hidden features... one of which is being able to click on a running process.. and set the "renice" from +20 (less priority) to -20 (highest priority). The best part.... it sticks between restarts... SO you want XYZ to get full attention all the time.. you set it once and it's done... I want to do the same thing (renice a process) on an iPad running a particular daemon.. and I don't know how to set a renice permanently. I can do it once, and it works fine... But the setting is lost on a reboot. I read somewhere.. Now, as for permanently resetting the priority of a process, this can't be done directly. You can fake it, however, with a shell script that starts the app and then immediately renice's it. Give that script a ".command" extension and it will be double-clickable in the GUI. Not very elegant, but it gets the job done. But as it says.. not very elegant, and I dont think this is how ATMonitor does it.... I found this thread.... http://superuser.com and they gave a way to do it as a launch argument, but no apparent way to save it as a persistent value... for instance - if the program wasn't going to be started by launchd... How do I set a permanent renice level, per executable binary, independent of it's PID, when, how or why it was launched?

    Read the article