  • What is causing a vm to exhibit packet loss?

    - by Joe Philllips
    We have a pretty nice piece of hardware set up to run multiple virtual machines in vmware and one of the vm's is an instance of Windows Server 2003 running SQL Server 2005. For some reason we occasionally see 10-20 seconds of straight packet loss to this machine from remote machines (my workstation) as well as other vm's on the same physical hardware. I am using PingPlotter to keep a close eye on the packet loss. So far we've turned off flow control on the NIC but we are already running out of other things to try. What might be causing this and how can I identify the problem? Note: We also have another server with a very similar configuration with the same type of problem to a lesser extent (because its not used as heavily?)

    Read the article

  • Dell Power Edge R515 - Replacing a Bad Hard Drive in a RAID

    - by LonnieBest
    I've ordered a new hard drive to replace a bad one in a Dell Power Edge R515. The manual covers obvious topics regarding physical replacing of hard drives, but I've never done this before on a production server where RAID is involved. I've heard people talk about this topic, and I've heard that some servers have RAID controllers that are smart enough to allow you to just put in the new drive (hot swap), and then the server will know automatically how to rebuild that drive to be what the old one was to the system. Where do I find the proper procedure for replacing a failed hard drive on a live production Dell Power Edge R515? Can someone with experience tell me how easy or hard this usually is?

    Read the article

  • HP DL380 G5 Predictive Drive Failure on a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • Can a power failure or forceful shutdown damage hardware?

    - by Vilx-
    Can computer hardware suffer damage from forceful shutdowns (holding the power button for five (5) seconds) or power failures? I believe that normal PC hardware does not suffer from this - after all, it's not much different than what they experience under a standard shutdown. But elsewhere I've read tht another person thought that it could do physical harm to the hard drive and possibly other components as well. He also said that the journaling features of filesystems are useless in face of power failures and were intended to help mitigate damage from system crashes. I think this is nonsense, but then again I lack the experience and knowledge to say it with certainty.

    Read the article

  • The cd command using variable to mapped NFS volume within ssh in linux script is not working

    - by Bhavya Maheshwari
    I have to do the following from within a bash script. The /VMNFS/ folder is present on linux box, from where script is run, and is mapped to the machine into which i am ssh'ing, as an NFS at /vmfs/volumes/VMNFS/. The second cd command doesn't work, neither with symbolic path name nor physical pathname. Why? and How to rectify this? #!/bin/bash ssh -2 [email protected] /bin/sh <<\EOF vmfile_path=`grep / vmvar_file` datastore_path=/vmfs/volumes/VMNFS/ cd $datastore_path && echo "The present working directory is" `pwd -P` esxi_vmfile_path_sub=`pwd -P` && echo "variable value is" $esxi_vmfile_path_sub esxi_vmfile_path=`echo $vmfile_path | sed "s:/VMNFS:$esxi_vmfile_path_sub:"` cd "$esxi_vmfile_path" EOF ***Output***: The current working directory is /vmfs/volumes/65335ec4-46d12e41 variable value is /vmfs/volumes/65335ec4-46d12e41 can't cd to /vmfs/volumes/65335ec4-46d12e41/TPAE7.5/

    Read the article

  • Gparted: Copy Greyed Out

    - by David
    I booted my system to a gparted linux live CD and I have two partitions: /dev/sda1 /dev/sda2 I want to move both of them to my new physical hard drive (called /dev/sdb). When I right click on /dev/sda1, I can choose copy and then paste it onto /dev/sdb. When I right click on /dev/sda2, copy is greyed out and there is a yellow exclamation point to the left of the disk. I know that the disk works since I can boot my computer from it. Why won't gparted let me copy /dev/sda2 to my new hard disk? Since the option is greyed out, I don't even get an error message. Thanks!

    Read the article

  • Why is my USB-to-VGA'd monitor working, but not showing in Display Settings?

    - by Strilanc
    I have a USB-to-VGA adapter, which I use to connect a second monitor to my laptop (totaling 3 screens). It worked alright with Vista. I upgraded to Windows 7, and now it no longer works properly (I downloaded the latest drivers just to get it to work on 7). The extra monitor is detected and used to extend the desktop (I can move things onto it, etc), but is not shown within the Control Panel. This is annoying because now I can't changes its resolution, set its logical position to match its physical position, etc. Can I do anything, besides waiting for better drivers? I'm mainly concerned with moving its logical position. (I'd also like to understand how Windows can use a monitor it can't detect. Weird.)

    Read the article

  • SharePoint Designer prompts for credentials when edited from IE8

    - by Rob Nicholson
    Our intranet is hosted using the free SharePoint services on Windows 2003. Consider the following page: http://vserver003/help/technology/multimedia/multimedia.htm On selecting "Edit with Microsoft Office SharePoint Designer" from IE8, SPD launches, opens the website and then the selected page - all is well. In order to make moving the intranet easier, we've set-up a DNS setting called intranet.company.local so you can also access the intranet that way: http://intranet.company.local/help/technology/multimedia/multimedia.htm However, when you edit this page, SPD designer prompts you for credential, i.e. domain\username and password. If you enter the details it opens fine. If you don't enter the details, the page still opens but not the website. Any ideas have to get around this prompt? Haven't a clue where to start looking. Thanks, Rob. PS. The same prompt occurs if you use the physical IP address.

    Read the article

  • Change user login in Windows 7 (after a misprint in username)

    - by Artem Russakovskii
    I have an install of Windows 7 that I've already put a few days into. Today I realized I've made a mistake in the username and it's driving me nuts (my personal OCD). While changing the physical folder name is perhaps possible, though quite involved, I do not want to open that can of worms. What I want to do is simply change the username I give when the login prompt shows up. I thought it's possible by just renaming the user account in the User Accounts but that didn't work. Is it possible to do then? Or is the only way to create another user and spend hour migrating everything I'd already customized to that user?

    Read the article

  • Various problems with software raid1 array built with Samsung 840 Pro SSDs

    - by Andy B
    I am bringing to ServerFault a problem that is tormenting me for 6+ months. I have a CentOS 6 (64bit) server with an md software raid-1 array with 2 x Samsung 840 Pro SSDs (512GB). Problems: Serious write speed problems: root [~]# time dd if=arch.tar.gz of=test4 bs=2M oflag=sync 146+1 records in 146+1 records out 307191761 bytes (307 MB) copied, 23.6788 s, 13.0 MB/s real 0m23.680s user 0m0.000s sys 0m0.932s When doing the above (or any other larger copy) the load spikes to unbelievable values (even over 100) going up from ~ 1. When doing the above I've also noticed very weird iostat results: Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 0.00 1589.50 0.00 54.00 0.00 13148.00 243.48 0.60 11.17 0.46 2.50 sdb 0.00 1627.50 0.00 16.50 0.00 9524.00 577.21 144.25 1439.33 60.61 100.00 md1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 0.00 1602.00 0.00 12816.00 8.00 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 And it keeps it this way until it actually writes the file to the device (out from swap/cache/memory). The problem is that the second SSD in the array has svctm and await roughly 100 times larger than the second. For some reason the wear is different between the 2 members of the array root [~]# smartctl --attributes /dev/sda | grep -i wear 177 Wear_Leveling_Count 0x0013 094% 094 000 Pre-fail Always - 180 root [~]# smartctl --attributes /dev/sdb | grep -i wear 177 Wear_Leveling_Count 0x0013 070% 070 000 Pre-fail Always - 1005 The first SSD has a wear of 6% while the second SSD has a wear of 30%!! It's like the second SSD in the array works at least 5 times as hard as the first one as proven by the first iteration of iostat (the averages since reboot): Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sda 10.44 51.06 790.39 125.41 8803.98 1633.11 11.40 0.33 0.37 0.06 5.64 sdb 9.53 58.35 322.37 118.11 4835.59 1633.11 14.69 0.33 0.76 0.29 12.97 md1 0.00 0.00 1.88 1.33 15.07 10.68 8.00 0.00 0.00 0.00 0.00 md2 0.00 0.00 1109.02 173.12 10881.59 1620.39 9.75 0.00 0.00 0.00 0.00 md0 0.00 0.00 0.41 0.01 3.10 0.02 7.42 0.00 0.00 0.00 0.00 What I've tried: I've updated the firmware to DXM05B0Q (following reports of dramatic improvements for 840Ps after this update). I have looked for "hard resetting link" in dmesg to check for cable/backplane issues but nothing. I have checked the alignment and I believe they are aligned correctly (1MB boundary, listing below) I have checked /proc/mdstat and the array is Optimal (second listing below). root [~]# fdisk -ul /dev/sda Disk /dev/sda: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00026d59 Device Boot Start End Blocks Id System /dev/sda1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sda2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sda3 4605952 814106623 404750336 fd Linux raid autodetect root [~]# fdisk -ul /dev/sdb Disk /dev/sdb: 512.1 GB, 512110190592 bytes 255 heads, 63 sectors/track, 62260 cylinders, total 1000215216 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0003dede Device Boot Start End Blocks Id System /dev/sdb1 2048 4196351 2097152 fd Linux raid autodetect Partition 1 does not end on cylinder boundary. /dev/sdb2 * 4196352 4605951 204800 fd Linux raid autodetect Partition 2 does not end on cylinder boundary. /dev/sdb3 4605952 814106623 404750336 fd Linux raid autodetect /proc/mdstat root # cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdb2[1] sda2[0] 204736 blocks super 1.0 [2/2] [UU] md2 : active raid1 sdb3[1] sda3[0] 404750144 blocks super 1.0 [2/2] [UU] md1 : active raid1 sdb1[1] sda1[0] 2096064 blocks super 1.1 [2/2] [UU] unused devices: Running a read test with hdparm root [~]# hdparm -t /dev/sda /dev/sda: Timing buffered disk reads: 664 MB in 3.00 seconds = 221.33 MB/sec root [~]# hdparm -t /dev/sdb /dev/sdb: Timing buffered disk reads: 288 MB in 3.01 seconds = 95.77 MB/sec But look what happens if I add --direct root [~]# hdparm --direct -t /dev/sda /dev/sda: Timing O_DIRECT disk reads: 788 MB in 3.01 seconds = 262.08 MB/sec root [~]# hdparm --direct -t /dev/sdb /dev/sdb: Timing O_DIRECT disk reads: 534 MB in 3.02 seconds = 176.90 MB/sec Both tests increase but /dev/sdb doubles while /dev/sda increases maybe 20%. I just don't know what to make of this. As suggested by Mr. Wagner I've done another read test with dd this time and it confirms the hdparm test: root [/home2]# dd if=/dev/sda of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 38.0855 s, 282 MB/s root [/home2]# dd if=/dev/sdb of=/dev/null bs=1G count=10 10+0 records in 10+0 records out 10737418240 bytes (11 GB) copied, 115.24 s, 93.2 MB/s So sda is 3 times faster than sdb. Or maybe sdb is doing also something else besides what sda does. Is there some way to find out if sdb is doing more than what sda does? UPDATE Again, as suggested by Mr. Wagner, I have swapped the 2 SSDs. And as he thought it would happen, the problem moved from sdb to sda. So I guess I'll RMA one of the SSDs. I wonder if the cage might be problematic. What is wrong with this array? Please help!

    Read the article

  • OpenVZ multiple networks on CTs

    - by user6733
    I have Hardware Node (HN) which has 2 physical interfaces (eth0, eth1). I'm playing with OpenVZ and want to let my containers (CTs) have access to both of those interfaces. I'm using basic configuration - venet. CTs are fine to access eth0 (public interface). But I can't get CTs to get access to eth1 (private network). I tried: # on HN vzctl set 101 --ipadd 192.168.1.101 --save vzctl enter 101 ping 192.168.1.2 # no response here ifconfig # on CT returns lo (127.0.0.1), venet0 (127.0.0.1), venet0:0 (95.168.xxx.xxx), venet0:1 (192.168.1.101) I believe that the main problem is that all packets flows through eth0 on HN (figured out using tcpdump). So the problem might be in routes on HN. Or is my logic here all wrong? I just need access to both interfaces (networks) on HN from CTs. Nothing complicated.

    Read the article

  • Securing a persistent reverse SSH connection for management

    - by bVector
    I am deploying demo Ubuntu 10.04 LTS servers in environments I do not control and would like to have an easy and secure way to administer these machines without having to have the destination firewall forward port 22 for SSH access. I've found a few guides to do this with reverse port (e.g. howtoforge reverse ssh tunneling guide) but I'm concerned with security of the stored ssh credentials required for the tunnel to be opened automatically. If the machine is compromised (primary concern is physical access to the machine is out of my control) how can I stop someone from using the stored credentials to poke around in the reverse ssh tunnel target machine? Is it possible to secure this setup, or would you suggest an alternate method?

    Read the article

  • what constitutes out-of-band access to a server?

    - by broiyan
    The first time I access my server with a new installation of Filezilla or Putty, I will get prompted that I should continue only if the RSA key shown to me is correct. The cloud provider has advice on their website that I ought to use their AJAX console to get a key out-of-band with which to compare to the one shown by Filezilla. The AJAX console is launched from a link on the cloud provider's website which requires a login. Exactly how is this AJAX console considered to be out-of-band when it obviously is not a form of physical access to the server?

    Read the article

  • setting up an access point from laptop to provide internet

    - by Avo
    i am trying to connect my wireless router as an access point from my laptop. the scenario is as follows: i have a wireless broadband connection at home, which i connect to using a username and a password. this username and password is unique, and can be used by one computer at a time!.. my sister and i can't have internet both at the same time! so im trying to connect my wireless router to my laptop with a physical cable so that i can provide internet via WiFi... first off, is this possible?!.. if not, what are my options? if it is possible, how do i set it up? a link to the appropriate steps would do as well, but i need it :(... thank you in advance, /av

    Read the article

  • MySQL Windows vs. Linux: performance, caveats, pros and cons?

    - by gravyface
    Looking for (preferrably) some hard data or at least some experienced anecdotal responses with regards to hosting a MySQL database (roughly 5k transactions a day, 60-70% more reads than writes, < 100k of data per transaction i.e. no large binary objects like images, etc.) on Windows 2003/2008 vs. a Debian-based derivative (Ubuntu/Debian, etc.). This server will function only as a database server with a separate Web server on another physical box; this server will require remote access for management (SSH for Linux, RDP for Windows). I suspect that the Linux kernel/OS will compete less than the Windows Server for resources, but for this I can't be certain. There's also security footprint: even with Windows 2008, I'm thinking that the Linux box can be locked down more easily than the Windows Server. Anyone have any experience with both configurations?

    Read the article

  • Google Apps for Business on a separate infrastructure?

    - by dustin
    Does anyone know if Google Apps for Business edition hosts the apps (gmail, calendar, etc.) on a physically separate infrastructure than the Standard (free) infrastructure? We've been growing increasingly annoyed with the lost/severely delayed email messages, downtime, etc. of Google Apps (standard) over time, and we are wondering if moving to the paid version would bring any benefits. Specifically, if the Business edition is not in some way on a different physical infrastructure, and we are in essence paying for a few small perks but still run on the usual standard/free setup, then we would probably have the same (or just as many) issues with the Business version. I've emailed Google's sales team responsible for GApps, but haven't heard anything back in 4 days, which already doesn't speak well for the service. So, anyone have any insight into this? Thanks in advance for any and all help :)

    Read the article

  • Web Folder size/quota reporting tool?

    - by nctrnl
    I am currently using a Visual Basic script to determine how big the web folders are and what quota is decided for each folder. The quota is in no way a physical limit, just a value inserted by me to decide whether a user is using too much space or not. The script does the job quite neatly and sends an html file by mail on a regular basis. The problem is that it's such a hassle to insert new quotas since I have to fiddle around with the code. A central "control panel" with an overview and ability to insert new quotas would be more suitable. Is there any software that can do the following: Scan specified folder/subfolders Report the file size and present it in some sort of interface (could be a php/mysql solution) Ability to specify a quota and see the difference value ? It is really important that the quota handling is made simple so that some non-technician can handle this.

    Read the article

  • Web Folder size/quota reporting tool?

    - by nctrnl
    I am currently using a Visual Basic script to determine how big the web folders are and what quota is decided for each folder. The quota is in no way a physical limit, just a value inserted by me to decide whether a user is using too much space or not. The script does the job quite neatly and sends an html file by mail on a regular basis. The problem is that it's such a hassle to insert new quotas since I have to fiddle around with the code. A central "control panel" with an overview and ability to insert new quotas would be more suitable. Is there any software that can do the following: Scan specified folder/subfolders Report the file size and present it in some sort of interface (could be a php/mysql solution) Ability to specify a quota and see the difference value ? It is really important that the quota handling is made simple so that some non-technician can handle this.

    Read the article

  • Why is my ethernet interface in promiscuous mode

    - by nhed
    I read that seeing a flag of M in netstat -i is the way to tell which of your interfaces is in promiscuous mode I run it and I see that eth1 is in promiscuous mode $ netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth1 1500 0 1770161198 0 0 0 57446481 0 0 0 BMRU lo 16436 0 97501566 0 0 0 97501566 0 0 0 LRU This seems to be the case on all the machines I checked (All Centos6.0, both virtual and physical), any idea why ethernet devices would be in such a mode unless someone was running any pcap based app (sudo lsof | grep pcap shows nothing)? I did not see any mention of promiscuous in any of the config files (sudo grep -r promis /etc) Any ideas what puts the interface into that mode and why? p.s. most of the posts I see seem to be security related, this is not that

    Read the article

  • how to copy sql server database on same server

    - by Sam
    I've got a SQL Server 2008 and want to make a copy of a database so I've got a 2nd Version of the database for testing on the same server. The database copy wizard is not able to copy the database, it always sends funny error Messages about missing objects (using SMO copy). When I try to make a backup and restore it under a different database name it still keeps the file names of the original database and overrides this (crashing the original database). So how do I copy a SQL database? Shutdown SQL Server, copy the physical files and attach them? Maybe a command line tool for database copy? Shouldn't there be an easy way to make a copy?

    Read the article

  • Only One GPU Detected in the Nvidia Quadro NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • What is the effect on LVM snapshot size when a file block is rewritten with it's original contents?

    - by NevilleDNZ
    I'm exploring using LVM snapshot's to off site incremental archives from a snapshot "master" file system. In essence: simply copy across only the files on the "master" that have changed since the last incremental copy to the "archive". Then snapshot the "archive" to retain the incremental. I am a bit puzzled as to the block usage behaviour of the archive's own incremental snapshot. I'm expecting that LVM is not smart enough to know that the "file block" is actually unchanged, and the a new copy will be allocated and written for the fresh "archive" file system. Can anyone confirm this, or point me to a document/page that gives some hints? BTW: the OS hard disk cache, hard disk physical cache and hard disk itself also doesn't need to do any actual "disk writes" as the "disk block" likewise is unnecessary. Any pointers to discussion of this style of optimisation would also be ineresting.

    Read the article

  • VMware two vSwitches Guests can't communicate between them

    - by Aaron R.
    I have some servers in this configuration: And I am not able, from VMGuest1, to ping either VMGuest3 or VMGuest4. I can, however, ping Host1 and Host2, which are attached to pSwitch1. The behavior is the same with VMGuest3 or 4 trying to ping VMGuest 1 or 2. I don't have promiscuity enabled for any of these switches, nor do I have a bridge set up inside ESXi for the virtual switches. I know that one of these options is usually necessary when trying to get connectivity between two virtual switches. These switches are connected, however, through their respective physical switches which are bridged together. Ping just times out, arp request looks like this: [root@vmguest1:~]# arp -a vmguest3 vmguest3.example.com (1.2.3.4) at <incomplete> on eth0 [root@vmguest1:~]# arp -a host1 host1.example.com (1.2.3.5) at 00:0C:64:97:1C:FF [ether] on eth0 VMGuest1 can reach hosts on pSwitch1, so why can't it get to hosts on vSwitch1 through pSwitch1 the same way?

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • Which tool / technology: System management for databases and dependent services

    - by Filburt
    I'm looking for advice on how to enable our team to take down and re-start our company systems for maintainance purposes. The scenario includes several Oracle db machines several MS SQL Server machines with multiple instances windows services (IIS etc.) BizTalk EAI solution Apache and Tomcat instances lots of scheduled tasks on win2003 and win2008 machines (physical and virtual). The main focus is on capture all dependencies between said databases and services and tasks connecting to them. At the moment an enterprise class solution is not an option. We are considering developing a solution driven by PowerShell scripts but I hope for some more suggestions.

    Read the article