Search Results

Search found 2840 results on 114 pages for 'ports'.

Page 90/114 | < Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >

  • Bypassing SQUID on freebsd with PF

    - by epema
    I have PF+SQUID31 on FREEBSD-9.0, and I want to have some hosts(aka goodguys) to bypass the proxy, so that torrents are not logged. Also, I am not sure about transparent. It means that I dont have to configure proxy settings on the client side right? I have tried doing a redirect no rdr on $int_if inet proto {tcp,udp} from 192.168.1.233/32 to any However, no luck :( Here is a quick look of my conf files: SQUID /usr/local/etc/squid/squid.conf http_port 192.168.1.1:8080 transparent RC /etc/rc.conf: gateway_enable="YES" pf_enable="YES" pf_rules="/usr/local/etc/pf.conf" pflog_enable="YES" squid_enable="YES" I have squid31 installed from ports with SQUID_PF "Enable transparent proxying with PF" on PF /usr/loca/etc/pf.conf: int_if="re0" ext_if="bge0" localnet="{ 192.168.1.0/24 }" table <goodguys> const { "192.168.1.219", "192.168.1.233" } set block-policy drop set skip on lo0 scrub in all fragment reassemble scrub out all random-id max-mss 1440 block in on $ext_if pass out on $ext_if keep state block in on $int_if pass in on $int_if inet proto tcp from $int_if:network to $int_if port 8080 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 21 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 22 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 53 keep state pass in on $int_if inet proto tcp from $int_if:network to any port { smtp, pop3 } keep state pass in on $int_if inet proto icmp from $int_if:network to $int_if keep state pass out on $int_if keep state What lines should I add in conf files? I am assuming that the problem is on the firewall(pf).

    Read the article

  • Possible to IPSec VPN Tunnel Public IP Addresses?

    - by caleban
    A customer uses an IBM SAS product over the internet. Traffic flows from the IBM hosting data center to the customer network through Juniper VPN appliances. IBM says they're not tunneling private IP addresses. IBM says they're tunneling public IP addresses. Is this possible? What does this look like in the VPN configuration and in the packets? I'd like to know what the source/destination ip/ports would look like in the encrypted tunneled IPSec Payload and in the IP packet carrying the IPSec Payload. IPSec Payload: source:1.1.1.101:1001 destination:2.2.2.101:2001 IP Packet: source:1.1.1.1:101 destination:2.2.2.1:201 Is it possible to send public IP addresses through an IPSec VPN tunnel? Is it possible for IBM to send a print job from a server on their network using the static-nat public address over a VPN to a printer at a customer network using the printer's static-nat public address? Or can a VPN not do this? Can a VPN only work with interesting traffic from and to private IP addresses?

    Read the article

  • UDP blocked by Windows XP Firewall when sending to local machine

    - by user36367
    I work for a software development company but the issue doesn't seem to be programming-related. Here is my setup: Windows XP Professional with Service Pack 3, all updated Program that sends UDP datagrams Program that receives UDP datagrams Windows Firewall set to allow inbound UDP datagrams on a specific port (Scope: Subnet) If I send a UDP datagram on any port to other, similar machines, it goes through. If I send the UDP datagram to the same computer running the program that sends (whether using broadcast, localhost IP or the specific IP of the machine), the receiver program gets nothing. I've traced the problem down to the Windows XP Firewall, as Windows 7 does not have this problem (and I do not wish to sully my hands with Vista). If the exception I create for that UDP port in the WinXP firewall is set for a Scope of Subnet the datagram is blocked, but if I set it to All Computers or specifically enter my network settings (192.168.2.161 or 192.168.2.0/255.255.255.0) it works fine. Using different UDP ports makes no difference. I've tried different programs to reproduce this problem (ServerTalk to send and either IP Port Spy or PortPeeker to receive) to make sure it's not our code that's the issue, and those programs' datagrams were blocked as well. Also, that computer only has one network interface, so there are no additional network weirdness. I receive my IP from a DHCP server, so this is a straightforward setup. Given that it doesn't happen in Windows 7 I must assume it's a defect in the Windows XP Firewall, but I'd think someone else would have encountered this problem before. Has anyone encountered anything like this? Any ideas?

    Read the article

  • VirtualBox VM running web server not accessible via external IP

    - by mwigdahl
    I have a Windows 7 machine running VirtualBox with an Ubuntu guest. The guest has a Bitnami LAMP stack installed. I have the guest configured for Bridged networking, and I can access the guest web server just fine from other machines on my LAN using the guest's IP. I'm trying to configure port forwarding so that I can access the web server from outside my LAN. (The router is a 2WIRE model as I'm on ATT's UVerse). I've set up port forwarding for ports 80 and 443 to the guest's IP in a similar manner to how I had them set up for my previous, physical web server, which worked just fine. However, I cannot seem to access the new, virtual web server using my external IP on the forwarded port. I suspected Windows Firewall issues on the host, but disabling it didn't solve the issue. Anyone have advice on what I should try next? EDIT: I've now attempted disabling the firewall on the guest with sudo ufw disable -- that doesn't seem to help either. However, after checking the router's port forwarding in more detail I may see the problem. My VM is named "linux" and in the router's configuration pages it shows up inconsistently. Sometimes it reports with a valid LAN IP and other times it doesn't show up with any IP. Even when it shows the correct IP the router indicates that it is disconnected. Could this be an indication that the 2WIRE router doesn't play well with VirtualBox's bridged networking mode?

    Read the article

  • iptables rules to allow HTTP traffic to one domain only

    - by Emily
    Hi everyone, I need to configure my machine as to allow HTTP traffic to/from serverfault.com only. All other websites, services ports are not accessible. I came up with these iptables rules: #drop everything iptables -P INPUT DROP iptables -P OUTPUT DROP #Now, allow connection to website serverfault.com on port 80 iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT iptables -A INPUT -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT #allow loopback iptables -I INPUT 1 -i lo -j ACCEPT It doesn't work quite well: After I drop everything, and move on to rule 3: iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT I get this error: iptables v1.4.4: host/network `serverfault.com' not found Try `iptables -h' or 'iptables --help' for more information. Do you think it is related to DNS? Should I allow it as well? Or should I just put IP addresses in the rules? Do you think what I'm trying to do could be achieved with simpler rules? How? I would appreciate any help or hints on this. Thanks a lot!

    Read the article

  • [Mac OS X] Terratec Cinergy Hybrid T USB XS is not recognized anymore

    - by Gabble
    I have used Terratec Cinergy Hybrid T USB XS for years now, alongside with Elgato EyeTV software. I am a happy and completely satisfied user! Since a couple of weeks the USB sitck stopped working on my MacPro1,1 (OS version 10.6.3): EyeTV does not see any device attached, and actually, the green led on the stick stays off. 1) it is not a USB port fault: I have unplugged any other USB/Firewire device and tried with different USB ports, to no avail (any other USB devices work as expected on any port) 2) I have completely uninstalled EyeTV software, including preferences and system daemons/extensions, rebooted and reinstalled the latest EyeTV. No way. 3) reset the PRAM. Nope. 4) checked the Apple System Profiler - USB: No device attached, The MacPro does not see it at all. ============= I need to say that: a) the device worked as a charm even with the latest OS 10.6.x (so it's not a OS upgrade cause) b) I have plugged the Terratec Cinergy Hybrid T USB XS to my MacBook5,1 where EyeTV is not installed and was never installed: The green led on the stick turns on, the growl bubble pops up, and the device is perfectly recognized by the system. Apple System Profiler says (sorry, Italian language): Cinergy Hybrid T USB XS (2882): ID prodotto: 0x005e ID fornitore: 0x0ccd Versione: 1.10 Numero di serie: 061102005755 Velocità: Fino a 12 Mb/sec Produttore: TerraTec Electronic GmbH ID posizione: 0x04100000 Corrente disponibile (mA): 500 Corrente necessaria (mA): 500 At this point I am pretty sure the Terratec stick is not damaged and there is something wrong with my MacPro. I kindly ask you: Is there a way to force my MacPro recognize the USB device? What can I check? Is there something that caches USB connection that can be reset? A OS reinstall would be the very last resort for me… Thanks in advance for any help you will offer!

    Read the article

  • How do I stop panning on a monitor that supports a specific resolution?

    - by IronicMuffin
    Hi all, I've been battling this for a few days now. Any and all help is appreciated. I have a planar monitor with a native res of 1280x1024. At one point, I had used PowerStrip to override "something" and set the res to 1600x1200, and it worked great. I then installed new intel graphics drivers for my 86895g (or w/e model) video card, which screwed up whatever settings I had. If I set it to 1600x1200 this time, it would set the res correctly, but give me a 1280x1024 viewport and the screen would pan when the mouse got to the edges of the screen. Absolutely not useful. Ok, so I was limited to 1280x1024 now. W/e. Now...enter new video card with two video ports. I have two monitors now and the latest nVidia drivers. I decide to try to get dual 1600x1200 going...ended up screwing the original monitor up so much now that it's at 1280x1024, with a 1024x768 viewport and panning! Absolutely not usable now. So what I need, and I can't seem to find on any forums, is help doing one or more of the following: Clearing out all monitor/edid info out of the windows registry without corrupting the registry. Actually correctly override the EDID values and get my sweet res back. Some other way of getting back to at least dual 1280x1024 with NO panning. Note: My device manager shows 4 monitors for some reason. My registry shows entries for all sorts of monitors that have been hooked up to the machine over the years. It's making it difficult to debug. Experience with PowerStrip would be helpful. I've been mucking with Phoenix EDID designer and MonInfo as well, but I'm stumbling around in the dark with these. Windows XP SP2 nVidia GeForce 6200 nVidia drivers: v258.96 Monitor: Planar PL 1910M Thanks!

    Read the article

  • Multi-WAN bonding across different media

    - by Tom O'Connor
    I've recently been thinking again about a product that Viprinet provide, basically they've got a pair of routers, one that lives in a datacentre, Their VPN Multichannel Hub and the on-site hardware, their VPN multichannel routers They've also got a bunch of interface cards (like HWICs) for 3G, UMTS, Ethernet, ADSL and ISDN adapters. Their main spiel seems to be bonding across different media. It's something that I'd really like to use for a couple of projects, but their pricing is really quite extreme, the hub is about 1-2k, the routers are 2-6k, and the interface modules are 200-600 each. So, what I'd like to know is, is it possible with a couple of stock Cisco routers, 28xx or 18xx series, to do something similar, and basically connect a bunch of different WAN ports, but have it all presented neatly as one channel back to the internet, with seamless (or nearly) failover if one of the WAN interfaces should fail. Basically, If i got 3x 3G to ethernet modems, and each on a different network, I'd like to be able to loadbalance/bond across all of them, without having to pay Viprinet for the privilege. Does anyone know how I'd go about configuring something for myself, based around standard protocols (or vendor specific ones), but without actually having to buy the Viprinet hardware?

    Read the article

  • IP-dependent local port-forwarding on Linux

    - by chronos
    I have configured my server's sshd to listen on a non-standard port 42. However, at work I am behind a firewall/proxy, which only allow outgoing connections to ports 21, 22, 80 and 443. Consequently, I cannot ssh to my server from work, which is bad. I do not want to return sshd to port 22. The idea is this: on my server, locally forward port 22 to port 42 if source IP is matching the external IP of my work's network. For clarity, let us assume that my server's IP is 169.1.1.1 (on eth1), and my work external IP is 169.250.250.250. For all IPs different from 169.250.250.250, my server should respond with an expected 'connection refused', as it does for a non-listening port. I'm very new to iptables. I have briefly looked through the long iptables manual and these related / relevant questions: http://serverfault.com/questions/57872/iptables-question-forwarding-port-x-to-an-ssh-port-of-different-machine-on-the-n http://serverfault.com/questions/140622/how-can-i-port-forward-with-iptables However, those questions deal with more complicated several-host scenarios, and it is not clear to me which tables and chains I should use for local port-forwarding, and if I should have 2 rules (for "question" and "answer" packets), or only 1 rule for "question" packets. So far I have only enabled forwarding via sysctl. I will start testing solutions tomorrow, and will appreciate pointers or maybe case-specific examples for implementing my simple scenario. Is the draft solution below correct? iptables -A INPUT [-m state] [-i eth1] --source 169.250.250.250 -p tcp --destination 169.1.1.1:42 --dport 22 --state NEW,ESTABLISHED,RELATED -j ACCEPT Should I use the mangle table instead of filter? And/or FORWARD chain instead of INPUT?

    Read the article

  • SSH sometimes screws up connection when terminal overflows?

    - by SeveQ
    I've got a problem with SSH on a Debian Lenny based server (it's a vHost within a Xen environment, booted on a Xen kernel). I hope someone can help me with this. The SSH connection seems somehow getting screwed up frequently when the terminal overflows (new lines beyond the bottom of the terminal, usually forcing it to scroll). The connection gets lost but not regularly disconnected. It nearly always happens when I do the following: an existing SSH connection gets disconnected (regularly) I order putty to reestablish the connection login-prompt appears at the very bottom of the putty terminal window I enter my login-name, press the enter key I'm asked for the password, I enter it, press the enter key and BOOM! Nothing more happens. I have to reconnect again. So it is reproducable. I'm not totally sure if the connection crashes before or after I enter the password. Furthermore it also happens when there is much text to be displayed (for example when I compile something or do an ls -l on a directory with many entries). Using 'screen', however, helps to reduces the frequency of occurence but doesn't solve the problem completely. It's occurence is independent from which terminal software I use. I mostly use putty but it also happens with other clients. I certainly hope somebody can help me solving this problem. Thanks in advance! //edit: I've just made a Wireshark trace of the ssh connection and there is nothing, I repeat, nothing different between the working and the failing connection (at least aside from frame numbers, ports and times that obviously can't be equal). This leads me to the assumption that the error has to happen on the server's side.

    Read the article

  • LogMeIn style remote access to NAS drive

    - by Mere Development
    I've been asked to setup some remote access to a NAS drive. The NAS drive will sit on a VLAN inside a network that uses a Cisco 891 IS router as gateway. The charity have no SSL-VPN licenses for the Cisco. At present there are no open ports or services on the Cisco itself and ideally we would like to keep it that way for a while, hence the request for a LogMeIn style service that's initiated from inside. We need multiple user access, about 10 max. Using LogMeIn on a machine connected to the NAS would only provide screen sharing I believe, and no concurrent connections (could be wrong?) The end users need to be able to read and write files to the NAS from Mac's and PC's around the globe. Read-only access from Mobile devices would be a bonus but not absolutely necessary. This is for a charity, non-commercial, but they are willing to spend if necessary. Cisco config knowledge is at a minimum so if I can avoid upsetting that delicate device I'll be happy :) Anyone have any clever ideas? I can provide more information on request. Thanks, Ben

    Read the article

  • Apache22 on FreeBSD - Starts, does not respond to requests

    - by NuclearDog
    Hey folks! I'm running Apache 2.2.17 with the peruser MPM on FreeBSD 8.2-RC1 on Amazon's EC2 (so it's XEN). It was installed from ports. My problem is that, although Apache is running, listening for, and accepting connections, it doesn't actually respond to any or show them in the log at all. If I telnet to the port it's listening on and type out an HTTP request: GET / HTTP/1.1 Host: asdfasdf And hit enter a couple of times, it just sits there... Nothing. No response requesting with a browser either. There doesn't appear to be anything helpful in the error log: [Sun Jan 09 16:56:24 2011] [warn] Init: Session Cache is not configured [hint: SSLSessionCache] [Sun Jan 09 16:56:25 2011] [notice] Digest: generating secret for digest authentication ... [Sun Jan 09 16:56:25 2011] [notice] Digest: done [Sun Jan 09 16:56:25 2011] [notice] Apache/2.2.17 (FreeBSD) mod_ssl/2.2.17 The access log stays empty: root:/var/log# wc httpd-access.log 0 0 0 httpd-access.log root:/var/log# I've tried with accf_http and accf_data both enabled and disabled, and with both the stock configuration and my customized config. I also tried uninstalling apache22-peruser-mpm and just installing straight apache22... Still no luck. I tried removing all of the LoadModule lines from httpd.conf and just re-enabled the ones that were necessary to parse the config. Ended up with only the following loaded: root:/usr/local/etc/apache22# /usr/local/sbin/apachectl -M Loaded Modules: core_module (static) mpm_peruser_module (static) http_module (static) so_module (static) authz_host_module (shared) log_config_module (shared) alias_module (shared) Syntax OK root:/usr/local/etc/apache22# Same results. Apache is definitely what's listening on port 80: root:/usr/local/etc/apache22# sockstat -4 | grep httpd root httpd 43789 3 tcp4 6 *:80 *:* root httpd 43789 4 tcp4 *:* *:* root:/usr/local/etc/apache22# And I know it's not a firewall issue as there is nothing running locally, and connecting from the local box to 127.0.0.1:80 results in the same issue. Does anyone have any idea what's going on? Why it would be doing this? I've exhausted all of my debugging expertise. :/ Thanks for any suggestions!

    Read the article

  • What is the best way to connect a 3 switches with a router?

    - by Carlos Morales
    Hello everyone, I'm trying to rebuild the network from my work and I was thinking what is the best way to connect three switches and a router. The router has 4 ports so I thought to connect 2 switches to the router (each switch connected with 2 cables to the router) and then connect the third switch to one of the others with two cables. So is like this, two cables from switch one to the router, two cables from switch two to the router and two cables from switch 3 to switch 1 or 2. So my questions are: Is it better to connect the router to each switch with a cable or the more cables you have the better? If I connect the switch 3 to switch 1 or 2 is it better to connect it with a cable or you get better performance with more cables. If I'm wrong and there is a better or more efficient way to connect them please let me know. The router is a Netgear RP114 (I'll upgrade it to a Sonicwall NSA 240), switch 1 is a Netgear GS748T, switch 2 is a Cisco Catalyst 2924-XL and switch 3 is a D-link DGS-1024D Thank you very much

    Read the article

  • python reports socket in use, netstat and others claim its not

    - by captainmish
    We have a strange socket issue with a RHES3 box: Python 2.4.1 (#1, Jul 5 2005, 19:17:11) [GCC 3.2.3 20030502 (Red Hat Linux 3.2.3-52)] Type "help", "copyright", "credits" or "license" for more information. >>> import socket >>> s = socket.socket() >>> s.bind(('localhost',12351)) Traceback (most recent call last): File "<stdin>", line 1, in ? File "<string>", line 1, in bind socket.error: (98, 'Address already in use') This seems normal, lets see what has that socket: # netstat -untap | grep 12351 {no output} # grep 12351 /proc/net/tcp {no output} # lsof | grep 12351 {no output} # fuser -n tcp 12351 {no output, repeating the python test fails again} # nc localhost 12351 {no output} # nmap localhost 12351 {shows port closed} Other high ports work fine (eg 12352 works) Is there something magic about this port? Is there somewhere else I can look? Where does python find out that socket is in use that netstat doesnt know about? Any other way I can find out what/if that socket is?

    Read the article

  • How can I get Windows 7 to work with two Nvidia graphics cards with different drivers?

    - by Max
    This is similar to this question, but I am using more similar cards with Windows 7. I just purchased a Zotac Nvidia GeForce 7200 GS. I have a motherboard with two PCI Express x16 slots. There is already an MSI Nvidia GeForce 8800 GTS being used as the primary card, driving two LCD monitors. I would like the Zotac to output to a TV via DVI-out. Unfortunately, when Windows detects the Zotac and installs its drivers, or I manually install them, Windows stops being able to boot up. If I remove them and re-install the MSI 8800 drivers, I can boot again, but Windows can no longer see the Zotac 7200--it shows up as a yellow triangle in Device Manager. I've read conflicting reports about this. Some people claim that Windows 7 will support multiple heterogeneous graphics card drivers, as long as they are all using the same driver API ("WDDM?"). Others say that they have to be using the exact same driver, or it won't work. Others claim that you have to use the exact same card. which is it, exactly? I know I can run the MSI 8800 in SLI if I purchase another, but I don't need that kind of power--I just need HD-out to my television. I read somewhere that running two cards in SLI precludes you from using 100% of their output ports, so I'm not sure if that's an option. I suppose I could also run two MSI 8800's without SLI, but again, that's more power than I need (and more money than I'd like to spend). Also, I don't think this exact model is even manufactured anymore. Any ideas?

    Read the article

  • Nginx > Varnish > Gunicorn Error Too many Redirections

    - by kollo
    I have the following config: Nginx Varnish Gunicorn Django I want to cache 2 versions of same site (mobile & web) with Varnish. Gunicorn : WEB: gunicorn_django --bind 127.0.0.1:8181 MOBILE: gunicorn_django --bind 127.0.0.1:8182 Nginx: WEB: server { listen 80; server_name www.mysite.com; location / { proxy_pass http://127.0.0.1:8282; # pass to Varnish proxy_set_header X-Real-IP $remote_addr; proxy_set_header Host $host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } } MOBILE: server { listen 80; server_name m.mysite.com; location / { proxy_pass http://127.0.0.1:8282; # pass to Varnish proxy_set_header X-Real-IP $remote_addr; proxy_set_header Host $host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } } Varnish: default.vcl backend mobile_mysite { .host = "127.0.0.1"; .port = "8182"; } backend mysite { .host = "127.0.0.1"; .port = "8181"; } sub vcl_recv { if (req.http.host ~ "(?i)^(m.)?mysite.com$") { set req.http.host = "m.mysite.com"; set req.backend = mobile_mysite; }elsif (req.http.host ~ "(?i)^(www.)?mysite.com$") { set req.http.host = "mysite.com"; set req.backend = mysite; } if (req.url ~ ".*/static") { /* do not cache static content */ return (pass); } } The problem: On Nginx if I setup Mobile version with Varnish (port 8282) and let WEB version with Gunicorn( port 8181), MOBILE is cached by varnish, both WEB & MOBILE works but WEB is not cached. If I set the proxy_pass of WEB version to Varnish (port 8282) and restart Nginx I got an error when accessing web version (www.mysite.com) "Too many redirections" . I Think my problem come from the Varnish config file, as the site works well if I setup Nginx proxy_pass to Gunicorn ports (MOBILE & WEB).

    Read the article

  • What is the best way to connect 3 switches with a router?

    - by Carlos Morales
    Hello everyone, I'm trying to rebuild the network from my work and I was thinking what is the best way to connect three switches and a router. The router has 4 ports so I thought to connect 2 switches to the router (each switch connected with 2 cables to the router) and then connect the third switch to one of the others with two cables. So is like this, two cables from switch one to the router, two cables from switch two to the router and two cables from switch 3 to switch 1 or 2. So my questions are: Is it better to connect the router to each switch with a cable or the more cables you have the better? If I connect the switch 3 to switch 1 or 2 is it better to connect it with a cable or you get better performance with more cables. If I'm wrong and there is a better or more efficient way to connect them please let me know. The router is a Netgear RP114 (I'll upgrade it to a Sonicwall NSA 240), switch 1 is a Netgear GS748T, switch 2 is a Cisco Catalyst 2924-XL and switch 3 is a D-link DGS-1024D Thank you very much

    Read the article

  • Private staff network within public network

    - by pianohacker
    I'm the sysadmin at a small public library. Since I got here a few years ago, I've been trying to set up the network in a secure and simple way. Security is a little tricky; the staff and patron networks need to be separated, for security reasons. Even if I further isolated the public wireless, I'd still rather not trust the security of our public computers. However, the two networks also need to communicate; even if I set up enough VMs so they didn't share any servers, they need to use the same two printers at the very least. Currently, I'm solving this with some jerry-rigged commodity equipment. The patron network, linked together by switches, has a Windows server connected to it for DNS and DHCP and a DSL modem for a gateway. Also on the patron network is the WAN side of a Linksys router. This router is the "top" of the staff network, and has the same Windows server connected on a different port, providing DNS and DHCP, and another, faster DSL modem (separate connections are very useful, especially as we heavily depend on some cloud-hosted software). tl;dr: We have a public network, and a NATed staff network within it. My question is; is this really the best way to do this? The right equipment would likely make my job easier, but anything with more than four ports and even rudimentary management quickly becomes a heavy hit on our budget. (My original question was about an ungodly frustrating DHCP routing issue, but I thought I'd ask whether my network was broken rather than asking about the DHCP problem and being told my network was broken.)

    Read the article

  • maximum number of connections Squid

    - by Isaac
    I have a Squid proxy server that controls all internet traffic for my network. I need a way to stop users from downloading big files (say 50MB) in my network. I banned some famous ports (e.g. torrent) but some downloads are possible by HTTP port. Obviously I cannot ban port 80! A simple solution is limiting maxmimum number of the simultaneous connections for each IP (e.g. 3 connections). It's possible in Squid with this config: acl ACCOUNTSDEPT 192.168.5.0/24 acl limitusercon maxconn 3 http_access deny ACCOUNTSDEPT limitusercon But this solution has really bad impact in web browsing, because any smart browser get different parts of a website by several connections simultaneously to speedup web browsing. But if we have a maximum number of connections, the browsers will fail to get some parts and the website will be shown partially and some parts/images/frames will not be shown. So, can we limit maximum number of persist connections? I think this policy will works: Specify Maximum number of connections that is alive for 10 seconds But Number of simultaneous connections for every IP is unlimited But how can we implement this policy when Squid? With which config? UPDATE: artifex and Tom Newton offered using a bandwidth-limiting approach to fight against downloaders. But bandwidth-limiting in Squid has a shortcoming: It's static and cannot dynamically change. So a person has a limited bandwidth not matter how many people are using internet (maybe nobody!) Also, this solution cannot help to stop people from downloading. They still can download but in a lower speed. But if we find a way to terminate persist connections (or any connection that is alive more than a specific time), downloading big files will be almost impossible (always there is some way!)

    Read the article

  • ISA 2000 and COD MW2 Steam

    - by twlichty
    OK, so maybe not the "proper use" of network resources, but we enjoy the odd COD game during lunch hours. When we played COD4, we had a dedicated server setup at the back of the server room. With MW2, we need to be able to connect to steam to be able to play multi-player. I've found this support article here: https://support.steampowered.com/kb%5Farticle.php?ref=8571-GLVN-8711 Which outlines all the ports I need to open. I went through and created the following rules in ISA 2000 (I'm stuck with 2000 for now). Protocol Definition: Steam Primary connection: Port 27000, UDP, Send Receive Secondary Connection: Port range 27001-27030 Send Receive Protocol Definition: Steam TCP In Primary connection: 27014, TCP, Inbound Secondary Connection: Port range: 27015-27050, Inbound Protocol Definition: Steam 4380 Primary connection: 4380, UDP, Send Receive When I start steam on my local workstation (I did add an exception to the Vista Firewall to allow steam), the steam client sits on "Updating Steam" for 5 minutes then errors out with: You must connect to the internet first. Any ideas? I assume I missed something. Thanks for your help.

    Read the article

  • Cisco Access switch is dropping large amount of end points

    - by user135458
    This afternoon, with no changes to the network, a switch suddenly started dropping off lots of connections. These connections would come back up a few minutes later, then another area connected to the switch would drop off. This is an older 4006 chassis switch which could in and of itself be a problem but I'm looking to see what else you all would look for in trying to find a root cause. Switch is connected via ports 1/1 and 1/2 in an etherchannel to a VSS core 1/1/42 and 2/1/42. Both sides are up and working however the CPU on the switch will spike up to 99% and that's when CRC errors start to hit the VSS core on one of those interfaces and end points start dropping off. We tried new transceivers and SFP's on each side of the link, same result. When we tried swapping the fiber patch cables on the access switch the CRC errors did not follow the fiber cables they stayed with port 1/2 on the access switch. So port 1/2 on the supervisor module looks like the culprit. We actually tried to create a new member of the ethernet channel by taking a fiber media converter to cat5 and make that a member of the port-channel but when we plugged it in you couldn't even reach the switch. I'm guessing that's unrelated and a problem with the media converter. As of right now we have left it in a state of only one fiber cable running to one side of the VSS core (1/1 Access Switch -- 2/1/42). I've sent some info into TAC and they are looking into the situation but does anyone else have any commands I could run or some troubleshooting I could look into in the meantime?

    Read the article

  • linux: mount old ATA disk to USB adapter

    - by 130490868091234
    I am trying to recover data from an old Linux that was installed in a computer on an ATA hard drive. I found a ScanLogic Corp. SL11R-IDE IDE Bridge (04ce:0002), an ATA adapter to USB 1.0 like the one in the picture: and after switching it on, I plugged it into a laptop with Ubuntu 12.04. I am used to the drives being automatically mounted, but this one doesn't show up in /media. After doing a dmesg, all I got is this: [215298.671924] usb 2-1.1: new full-speed USB device number 5 using ehci_hcd [215298.767330] scsi19 : usb-storage 2-1.1:1.0 [215299.841701] usb 2-1.1: reset full-speed USB device number 5 using ehci_hcd [215300.017258] usb 2-1.1: reset full-speed USB device number 5 using ehci_hcd [215300.197050] usb 2-1.1: reset full-speed USB device number 5 using ehci_hcd [215300.372730] usb 2-1.1: reset full-speed USB device number 5 using ehci_hcd I tried plugging in the adapter to the three different USB ports in my laptop (one of them USB 3.0), but got no luck with any of them. I get different devices under, for example: /dev/bus/usb/003/002 or /dev/bus/usb/002/004, but I don't get any /dev/sdbN links. The output blkid -o list -c /dev/null is just the laptop's partitions. I have tried taking out the jumper, putting it as master and as CS Enabled, but didn't change the result. Any ideas?

    Read the article

  • .htaccess redirect to error page if port is not 80

    - by Momo
    I'm running a portable server through usb stick. The thing is I also have WAMP installed in my local machine and Apache somehow gets started on windows startup, because of some random reason which I don't recall now and it can't be changed. I want to prepare my portable server in situations like this, so closing httpd.exe from process and starting my portable server is not an option. Anyway, because of already active httpd.exe my portable server's WordPress site can only be accessed through localhost:81 - this is a problem as WP site is very dependent on the URL and I don't want to include the url with port on WP database. Here is what I want to do through .htaccess: On any path except for error.php file check if not port 80 If not port 80 redirect to /error.php?code=port It it possible for it to have priority over WP redirection or URL handling? In the error.php I provided info on how to manually close httpd.exe and such so my family and friends can access the portable site. It's sort of like a gallery and calender application for events and other such stuff... Please help? I'm I can't figure it out at all. I know others may not have apache already running, but I want to prepare for such a situation. Something like the following, but the following doesn't work. # BEGIN WordPress <IfModule mod_rewrite.c> <If "%{SERVER_PORT} = 80"> RewriteEngine On RewriteBase / RewriteRule ^index\.php$ - [L] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.php [L] </If> <Else> RewriteEngine On RewriteRule ^(error.php)($|/) - [L] RewriteRule ^(.*)$ /error.php?code=port [L] </Else> </IfModule> # END WordPress By the way, the portable server Server2Go automatically generates vhosts based o the hostname set on it's config file and changes ports if the port (e.g. 80) is already open.

    Read the article

  • Suddenly can't send E-Mails with Apple Mail to Gmail SMTP

    - by slhck
    Hi all, I have a weird problem that started just today. I am using Apple Mail on a Leopard machine, connecting to Gmail. Fetching e-mail works just fine. My SMTP settings are also correct. Still, I can't send mail, it will display a pop up saying that "transferring the content to the mail server" failed (translation from German, could be different in English OS X versions). I have verified the following: My SMTP settings are definitely correct. I have not changed them and the issue appeared today. Also, I went through the Apple online configuration for Gmail accounts and did not have to adjust any setting. I can run network diagnosis and it will connect to both POP and SMTP servers without a problem (all green lights) The Telnet details will show me the HELO message from the Gmail servers, so there's no authentication failure. Console.app will not show any messages related to "mail" when I try to send the mail, so there's no specific error message The mail I'm trying to send does not have an attachment, it is plaintext only I can login to gmail.com and send mails without a problem The recipient address exists and contains no syntax errors I can also not send mails to myself When using another IP and ISP (through VPN), it still doesn't work As for my settings: I connect to smtp.gmail.com and for advanced settings I choose password-based authentication with user: [email protected] and my password. I let Apple Mail try the default ports (for SSL and TLS, respectively). Again: I have not changed a thing between yesterday and today. What is causing that strange behavior? Any help would be much appreciated.

    Read the article

  • Upstart multiple instances of service not working

    - by Dax
    I started playing with MongoDB on Lucid. Now I would like to run a DB and Config server on the same box. They both use the same binary to launch, but with different config files and running on different ports. All directories for log and lib is split so one goes to mongodb and the other to mongoconf. Each process can be started without any problems on their own. start mongodb stop mongodb start mongoconf stop mongoconf But if I try to start both, the second one would just start and exit. Using 'initctl log-priority debug' I got the following in the logs. Jan 6 12:44:12 mongo4 init: event_finished: Finished started event Jan 6 12:44:12 mongo4 init: job_process_handler: Ignored event 1 (1) for process 5690 Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) main process (5690) terminated with status 1 Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) goal changed from start to stop Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) state changed from running to stopping man 5 init shows that you can use instance names to differentiate the two. I tried using 'instance mongoconf' in the on upstart script and 'instance mongodb' in the other one, and it still fails. I can manually start the other process, so there is definitely no conflicts on port numbers or directories. Any ideas on what to try or how to get output on why it is 'terminated with status 1'? Thanx

    Read the article

< Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >